SRGDT 5

You might also like

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 6

DESIGN CRITERIA

DEAD LOAD (table 204-2) LIVE LOAD (table 205-1)

Unit Weight of Concrete 24 kN/m3 OCCUPANY: HOSPITAL


CEILING Office use 2.40 kPa
0.48 kPa Lobbies 4.80 kPa
Suspended Metal Lath & Gypsum Plaster
Wards and rooms 1.90 kPa
FLOOR FINISHES 2.90 kPa
Laboratories
Cement Finish (25 mm) on stone concrete fill 1.53 kPa
Operating rooms 2.90 kPa
MASONRY Corridors above ground floor 3.80 kPa
3.30 kPa Restroom 1.90 kPa
Exterior Wall Full Grout (150 mm) 3.17 kPa Stairs 4.80 kPa
Exit Facilities 4.80 kPa
Interior Wall Full Grout Grout (100 mm)
FRAME PARTITION 1.00 kPa
0.10 kPa
Interior Partition
ELECTROMECANICAL
FLOOR SLAB
S2 (TWO-WAY SLAB) S2 (TWO-WAY SLAB) S3 (TWO-WAY SLAB)

P P P
SLAB THICKNESS; T = SLAB THICKNESS; T = SLAB THICKNESS; T =
180 180 180

2(7.6 + 7.6) 2(4.10 + 5.60) 2(3.25 + 2.0)


T= = 0.17 m T= = 0.11 m T= = 0.06m
180 180 180

𝐒𝐄𝐋𝐅 𝐖𝐄𝐈𝐆𝐇𝐓, 𝐒𝐄𝐋𝐅 𝐖𝐄𝐈𝐆𝐇𝐓, 𝐒𝐄𝐋𝐅 𝐖𝐄𝐈𝐆𝐇𝐓,

kN kN kN
24 x 0.17 m = 4.08 kPa 24 x 0.11 m = 2.64 kPa 24 x 0.06 m = 1.4 kPa
m3 m3 m3

DEAD LOADS = SUSPENDED METAL LATH & GYPSUM PLASTER + DEAD LOADS = SUSPENDED METAL LATH & GYPSUM PLASTER + DEAD LOADS = SUSPENDED METAL LATH & GYPSUM PLASTER +
CEMENT FINISH (25 MM) ON STONE CONCRETE FILL+INTERIOR CEMENT FINISH (25 MM) ON STONE CONCRETE FILL+INTERIOR CEMENT FINISH (25 MM) ON STONE CONCRETE FILL+INTERIOR
PARTITION + ELECTROMECHANICAL PARTITION + ELECTROMECHANICAL PARTITION + ELECTROMECHANICAL

DL = 0.48 + 1.53 + 1.0 + 0.10 = 𝟑. 𝟏𝟏 𝐤𝐏𝐚 DL = 0.48 + 1.53 + 1.0 + 0.10 = 3.11 kPa DL = 0.48 + 1.53 + 1.0 + 0.10 = 3.11 kPa

TOTAL DEAD LOAD = DL + SELF WEIGHT TOTAL DEAD LOAD = DL + SELF WEIGHT TOTAL DEAD LOAD = DL + SELF WEIGHT

TOTAL DEAD LOAD = 4.08 + 3.11 = 𝟕. 𝟏𝟗 𝐤𝐏𝐚 TOTAL DEAD LOAD = 2.64 + 3.11 = 𝟓. 𝟕𝟓 𝐤𝐏𝐚 TOTAL DEAD LOAD = 1.40 + 3.11 = 𝟒. 𝟓𝟏 𝐤𝐏𝐚

LIVE LOAD = BASIC FLOOR AREA+ CORRIDORS ABOVE GROUND FLOOR LIVE LOAD = BASIC FLOOR AREA+ CORRIDORS ABOVE GROUND FLOOR LIVE LOAD = BASIC FLOOR AREA

LL = 1.90 + 3.0 = 𝟒. 𝟗𝟎 𝐤𝐏𝐚 LL = 1.90 + 3.0 = 𝟒. 𝟗𝟎 𝐤𝐏𝐚 LL = 𝟏. 𝟗𝟎 𝐤𝐏𝐚

TOTAL LOAD = DL + LL TOTAL LOAD = DL + LL TOTAL LOAD = DL + LL

TOTAL LOAD = 𝟏𝟐. 𝟎𝟗 𝐤𝐏𝐚 TOTAL LOAD = 𝟏𝟎. 𝟔𝟓 𝐤𝐏𝐚 TOTAL LOAD = 𝟔. 𝟒𝟏 𝐤𝐏𝐚
S4 (TWO-WAY SLAB) S5 (TWO-WAY SLAB) S6 (TWO-WAY SLAB)

P P P
SLAB THICKNESS; T = SLAB THICKNESS; T = SLAB THICKNESS; T =
180 180 180

2(5.6 + 7.6) 2(7.60 + 4.10) 2(3.25 + 2.0)


T= = 0.15 m T= = 0.13 m T= = 0.06m
180 180 180

𝐒𝐄𝐋𝐅 𝐖𝐄𝐈𝐆𝐇𝐓, 𝐒𝐄𝐋𝐅 𝐖𝐄𝐈𝐆𝐇𝐓, 𝐒𝐄𝐋𝐅 𝐖𝐄𝐈𝐆𝐇𝐓,

kN kN kN
24 x 0.15 m = 3.60 kPa 24 x 0.13 m = 3.12 kPa 24 x 0.06 m = 1.4 kPa
m3 m3 m3

DEAD LOADS = SUSPENDED METAL LATH & GYPSUM DEAD LOADS = SUSPENDED METAL LATH & GYPSUM
DEAD LOADS = SUSPENDED METAL LATH & GYPSUM PLASTER + PLASTER + CEMENT FINISH (25 MM) ON STONE PLASTER + CEMENT FINISH (25 MM) ON STONE
CEMENT FINISH (25 MM) ON STONE CONCRETE FILL+INTERIOR CONCRETE FILL+INTERIOR PARTITION + CONCRETE FILL + ELECTROMECHANICAL
PARTITION + ELECTROMECHANICAL ELECTROMECHANICAL
DL = 0.48 + 1.53 + 1.0 + 0.10 = 2.11 kPa
DL = 0.48 + 1.53 + 1.0 + 0.10 = 3.11 kPa DL = 0.48 + 1.53 + 1.0 + 0.10 = 3.11 kPa
TOTAL DEAD LOAD = DL + SELF WEIGHT
TOTAL DEAD LOAD = DL + SELF WEIGHT TOTAL DEAD LOAD = DL + SELF WEIGHT
TOTAL DEAD LOAD = 1.40 + 2.11 = 𝟑. 𝟓𝟏 𝐤𝐏𝐚
TOTAL DEAD LOAD = 3.60 + 3.11 = 𝟔. 𝟕𝟏 𝐤𝐏𝐚 TOTAL DEAD LOAD = 3.12 + 3.11 = 𝟔. 𝟐𝟑 𝐤𝐏𝐚

LIVE LOAD = BASIC FLOOR AREA LIVE LOAD = RESTROOM + CORRIDORS ABOVE GROUND FLOOR LIVE LOAD = CORRIDORS ABOVE GROUND FLOOR

LL = 1.90 kPa LL = 2.4 + 3.0 = 𝟓. 𝟒𝟎 𝐤𝐏𝐚 LL = 𝟑. 𝟎𝐤𝐏𝐚

TOTAL LOAD = DL + LL
TOTAL LOAD = DL + LL TOTAL LOAD = DL + LL
TOTAL LOAD = 𝟖. 𝟔𝟏 𝐤𝐏𝐚
TOTAL LOAD = 𝟏𝟏. 𝟔𝟑 𝐤𝐏𝐚 TOTAL LOAD = 𝟔. 𝟓𝟏 𝐤𝐏𝐚
S1 (ONE-WAY SLAB)

L
SLAB THICKNESS; T =
24
7
T= = 0.30 m
24
𝐒𝐄𝐋𝐅 𝐖𝐄𝐈𝐆𝐇𝐓,

kN
24 x 0.30 m = 7.20 kPa
m3
DEAD LOADS = SUSPENDED METAL LATH & GYPSUM PLASTER +
CEMENT FINISH (25 MM) ON STONE CONCRETE FILL+INTERIOR
PARTITION + ELECTROMECHANICAL

DL = 0.48 + 1.53 + 1.0 + 0.10 = 3.11 kPa

TOTAL DEAD LOAD = DL + SELF WEIGHT

TOTAL DEAD LOAD = 7.2 + 3.11 = 𝟏𝟎. 𝟑𝟏 𝐤𝐏𝐚

LIVE LOAD = CORRIDORS ABOVE GROUND FLOOR

LL = 𝟑. 𝟖𝐤𝐏𝐚

TOTAL LOAD = DL + LL

TOTAL LOAD = 𝟏𝟒. 𝟏𝟏 𝐤𝐏𝐚


S8 (TWO-WAY SLAB) S9 (TWO-WAY SLAB) S10 (TWO-WAY SLAB)

P P P
SLAB THICKNESS; T = SLAB THICKNESS; T = SLAB THICKNESS; T =
180 180 180

2(5 + 4) 2(8 + 5) 2(8.75 + 5)


T= = 0.15 m T= = 0.15 m T= = 0.15 m
180 180 180
𝐒𝐄𝐋𝐅 𝐖𝐄𝐈𝐆𝐇𝐓, 𝐒𝐄𝐋𝐅 𝐖𝐄𝐈𝐆𝐇𝐓, 𝐒𝐄𝐋𝐅 𝐖𝐄𝐈𝐆𝐇𝐓,

kN kN kN
24 x 0.15 m = 3.60 kPa 24 x 0.15 m = 3.60 kPa 24 x 0.15 m = 3.60 kPa
m3 m3 m3
DEAD LOADS = SUSPENDED METAL LATH & GYPSUM DEAD LOADS = SUSPENDED METAL LATH & GYPSUM DEAD LOADS = SUSPENDED METAL LATH & GYPSUM
PLASTER + CEMENT FINISH (25 MM) ON STONE PLASTER + CEMENT FINISH (25 MM) ON STONE PLASTER + CEMENT FINISH (25 MM) ON STONE
CONCRETE FILL+INTERIOR PARTITION + CONCRETE FILL+INTERIOR PARTITION + CONCRETE FILL+INTERIOR PARTITION +
ELECTROMECHANICAL ELECTROMECHANICAL ELECTROMECHANICAL

DL = 0.48 + 1.53 + 1.0 + 0.10 = 3.11 kPa DL = 0.48 + 1.53 + 1.0 + 0.10 = 3.11 kPa DL = 0.48 + 1.53 + 1.0 + 0.10 = 3.11 kPa

TOTAL DEAD LOAD = DL + SELF WEIGHT TOTAL DEAD LOAD = DL + SELF WEIGHT TOTAL DEAD LOAD = DL + SELF WEIGHT

TOTAL DEAD LOAD = 3.6 + 3.11 = 𝟔. 𝟕𝟏 𝐤𝐏𝐚 TOTAL DEAD LOAD = 3.60 + 3.11 = 𝟔. 𝟕𝟏 𝐤𝐏𝐚 TOTAL DEAD LOAD = 3.60 + 3.11 = 𝟔. 𝟕𝟏 𝐤𝐏𝐚

LIVE LOAD = EXTERIOR BALCONIES LIVE LOAD = EXTERIOR BALCONIES LIVE LOAD = EXTERIOR BALCONIES

LL = 𝟐. 𝟗𝟎 𝐤𝐏𝐚 LL = 𝟑. 𝟖 𝐤𝐏𝐚 LL = 𝟒. 𝟖 𝐤𝐏𝐚

TOTAL LOAD = DL + LL TOTAL LOAD = DL + LL TOTAL LOAD = DL + LL

TOTAL LOAD = 𝟗. 𝟔𝟏 𝐤𝐏𝐚 TOTAL LOAD = 𝟏𝟎. 𝟓𝟏 𝐤𝐏𝐚 TOTAL LOAD = 𝟏𝟏. 𝟓𝟏 𝐤𝐏𝐚
S11 (TWO-WAY SLAB)

P
SLAB THICKNESS; T =
180

2(7.5 + 5)
T= = 0.15 m
180
𝐒𝐄𝐋𝐅 𝐖𝐄𝐈𝐆𝐇𝐓,

kN
24 x 0.15 m = 3.60 kPa
m3
DEAD LOADS = SUSPENDED METAL LATH & GYPSUM
PLASTER + CEMENT FINISH (25 MM) ON STONE
CONCRETE FILL+INTERIOR PARTITION +
ELECTROMECHANICAL

DL = 0.48 + 1.53 + 1.0 + 0.10 = 3.11 kPa

TOTAL DEAD LOAD = DL + SELF WEIGHT

TOTAL DEAD LOAD = 3.60 + 3.11 = 𝟔. 𝟕𝟏 𝐤𝐏𝐚

LIVE LOAD = EXTERIOR BALCONIES

LL = 𝟒. 𝟖 𝐤𝐏𝐚

TOTAL LOAD = DL + LL

TOTAL LOAD = 𝟏𝟏. 𝟓𝟏 𝐤𝐏𝐚