Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Data sheet for SINAMICS Power Module PM240-2

MLFB-Ordering data
6SL3210-1PE31-5UL0

Figure similar

Client order no. : Item no. :


Order no. : Consignment no. :
Offer no. : Project :
Remarks :

Rated data General tech. specifications

Input Power factor λ 0.95

Number of phases 3 / 3 AC Offset factor cos φ 0.99

Line voltage 380 ... 480 V ±10 % Efficiency η 0.98

Line frequency 47 ... 63 Hz Sound pressure level (1m) 68 dB

Rated current (LO) 140.00 A Power loss 1.78 kW

Rated current (HO) 117.00 A


Ambient conditions
Output
Cooling Internal air cooling
Number of phases 3 AC
Cooling air requirement 0.153 m³/s
Rated voltage 400 V
Installation altitude 1000 m
Rated current (LO) 145.00 A
Ambient temperature
Rated current (HO) 110.00 A
Operation LO -20 ... 40 °C (-4 ... 104 °F)
Max. output current 220.00 A
Operation HO -20 ... 50 °C (-4 ... 122 °F)
Rated power IEC 400V (LO) 75.00 kW
Transport -40 ... 70 °C (-40 ... 158 °F)
Rated power NEC 480V (LO) 100.00 hp
Storage -40 ... 70 °C (-40 ... 158 °F)
Rated power IEC 400V (HO) 55.00 kW
Relative humidity
Rated power NEC 480V (HO) 75.00 hp

Pulse frequency 4 kHz Max. operation 95 % RH, condensation not permitted

Output frequency for vector control 0 ... 200 Hz

Output frequency for V/f control 0 ... 550 Hz

Overload capability

Low Overload (LO)

1.1 x rated output current (i.e. 110 % overload) for 57 s with a cycle time of 300 s 1.5 × rated output current (i.e. 150 % overload) for 3 s with a cycle time of 300 s

High Overload (HO)

1.5 × output current rating (i.e., 150 % overload) for 57 s with a cycle time of 300 s 2 × output current rating (i.e., 200 % overload) for 3 s with a cycle time of 300 s

Technical data are subject to change! There may be discrepancies between calculated and rating plate values.
Generated Sat May 26 20:52:17 CEST 2018
Page 1 of 2
Data sheet for SINAMICS Power Module PM240-2

MLFB-Ordering data
6SL3210-1PE31-5UL0

Figure similar

Mechanical data Connections


Degree of protection IP20 Line side

Size FSF Version M10 bolt

Net weight 57.00 kg Conductor cross-section 35.00 ... 120.00 mm²

Width 305.0 mm Motor end

Height 708.0 mm Version M10 bolt

Depth 357.0 mm Conductor cross-section 35.00 ... 120.00 mm²

Converter losses to EN 50598-2* DC link (for braking resistor)

Efficiency class Version Screw-type terminals


IE2

Comparison with the reference converter (90% / Conductor cross-section 25.00 ... 70.00 mm²
-0.42 %
100%)
PE connection M10 screw studs

I Max. motor cable length


1395.3 W (1.39 %) 1606.3 W (1.60 %) 1953.8 W (1.94 %)
100% Shielded 300 m

Unshielded 450 m

Standards
791.2 W (0.79 %) 870.5 W (0.87 %) 984.7 W (0.98 %)
50%
UL, cUL, CE, C-Tick (RCM), SEMI F47
Compliance with standards
586.4 W (0.58 %) 621 W (0.62 %)
25%

CE marking Low-voltage directive 2006/95/EC

50% 90% f
The percentage values show the losses in relation to the rated apparent power of the converter.

The diagram shows the losses for the points (as per standard EN 50598) of the relative torque
generating current (I) over the relative motor stator frequency(f). The values are valid for the basic
version of the converter without options/components.

*converted values

Technical data are subject to change! There may be discrepancies between calculated and rating plate values.
Generated Sat May 26 20:52:17 CEST 2018