RESUMEN RESULTADOS DEL LABORATORIO

Para todas las pruebas el ángulo de elevación es de 160° y A_


ángulo 159,25° y con una longitud de 100mm

∅ de la Energia Fuerza de
# probeta S_Angulo Absorbida impacto
(mm) (J) (KJ/m^2)

1 6.9 157.45 0.3 14.04


2 6.9 154.8 0.772 36.14
3 7 154.44 0.85 39.79
4 7.3 155.16 0.715 22.91
5 7.5 154.39 0.87 27.88
6 7.9 154.3 0.87 27.88
7 8 152.82 1.17 37.5
8 8.8 150.52 1.622 53.26
9 8.8 151.6 1.422 45.57
10 8.9 154.84 0.772 36.14
11 8.9 150.61 1.64 52.56
12 9.4 151.69 1.422 45.57
13 9.4 151.78 1.402 44.93
14 9.6 143.23 3.457 110.8
15 9.6 142.83 0.3565 114.26
16 9.8 147.24 2.43 77.88
17 9.85 145.98 2.752 88.2
18 10 139.18 4.612 147.82
19 11.9 133.06 6.517 208.87
20 13.47 123.48 9.907 230.74
21 14.43 136.17 5.522 258.52
22 15.5 110.65 15.027 481.63
23 134.95 5.902 189.16
24 16.3 102.73 18.43 0
25 16.3 106.2 16.905 541.82
26 16.16 123.66 9.832 460.29
27 16.9 102.76 10.43 453.4
28 17.15 99.76 19.755 0
29 22.02 0,71,28 32.405 0
30 25 72.58 31.85 0
4.0115646252
10.3230929687
11.0436736757
8.54183231
9.8466260663
8.8747430897
11.638489188
13.3344843279
11.6902815747
6.204803134
13.1811880048
10.2455342366
10.1014338957
23.8807319106
2.462678891
16.108119467
18.0578769063
29.3616203133
29.2984414185
34.7614345864
16.8831881288
39.8198490882
0
44.1611979743
40.507056525
23.9689978644
23.248857679
42.7601780559
42.5469189749
32.4429351943
Diametro (mm) Energia absorbida (J)
6.9 4.0115646252
6.9 10.3230929687
7 11.0436736757
7.3 8.54183231

Media 8.4800408949
Varianza 19.9672801732
3.3968409469
6.5722130349
0.003818179
7.4850380835

ERROR 2.6811621688
diferencia 0.5
Numero de muestras 57.509044603
Diametro (mm) Energia absorbida (J)
7.5 9.8466260663
7.9 8.8747430897
8 11.638489188

Media 10.1199527814
Varianza 0.0747074932
1.5505471761
2.3059528184
1.3104024959

ERROR 1.1218335692
diferencia 0.5
Numero de muestras 10.0680844564
Diametro (mm) Energia absorbida (J)
8.8 13.3344843279
8.8 11.6902815747
8.9 6.204803134
8.9 13.1811880048

Media 11.1026892603
Varianza 4.9809092235
0.3452647279
23.989288507
4.3201570306
8.4089048723

ERROR 2.8418149552
diferencia 0.5
Numero de muestras 64.6072979146
Diametro (mm) Energia absorbida (J)
9.4 10.2455342366
9.4 10.1014338957
9.6 23.8807319106
9.6 2.462678891
9.8 16.108119467
9.85 18.0578769063

Media 13.4760625512
Varianza 10.4363131913
11.3881185623
108.2571444784
121.2946196473
6.9277236078
20.9930227847
46.5494903786

ERROR 5.4593119566
Diferencia 0.5
Numero de muestras 357.6490444772
Diametro (mm) Energia absorbida (J)
15.5 39.8198490882
16.3 44.1611979743
16.3 40.507056525

Media 41.4960345292
Varianza 2.8095976325
7.1030961893
0.9780774927
3.6302571049

ERROR 1.8672168925
Diferencia 0.5
Numero de muestras 27.8919913881