GETTING THE MOST FROM

CORIOLIS FLOWMETERS
The tradeoff between accuracy and drainability helps determine the selection
By Vince Salupo, Eli Lilly and Franki Parson, Emerson Process Management, Micro Motion Division

flowmeters measure measure of mass flow rate. straight-tube meters must be sized and
flow directly, by taking advantage of the Coriolis flowmeters can be used installed carefully. The ASME BPE-2005
Coriolis effect. Simply stated, the inertial in many areas of pharmaceutical Bioprocessing Equipment Standard,
effects caused by a fluid flowing through manufacturing. A particular strength Part SD-3.12.1, provides guidance
a tube are directly proportional to the of the technology is the fact that it for ensuring full system drainability
mass flow of the fluid. In a Coriolis isolates the process. The only part of the in horizontal piping and in-line
flowmeter, vibration is induced in the flowmeter that comes in contact with the measurement equipment.
process-filled flow tube(s), with the mass process is the inside of the flow tubes, In some applications, accuracy
flow rate captured by measuring the time which are made of corrosion-resistant and repeatability are paramount to
delay between the inlet and the outlet of metal alloys. There are no fluids or parts success. In others, unrestricted flow
the sensor. that can be exposed to the process in the is the critical factor. The accuracy
These meters also provide a direct event of device failure. of a straight-tube Coriolis meter
and independent density measurement, is determined by the material of
which is proportional to the vibrational CLEANABILITY AND construction and the sensitivity of the
frequency of the tubes. As the process DRAINABILITY components used to measure time
fluid becomes denser and heavier, the Most applications in pharmaceutical delay. At any flow rate, the sensitivity
vibrational frequency of the flow tubes manufacturing require a high level of (accuracy) decreases as the sensor tube’s
decreases. cleanability. When systems are cleaned in inside diameter increases.
There are two basic styles of Coriolis place, drainability is required. The smallest working sensor for
flowmeters: (Dual) bent tube and The flow tubes within Coriolis meters many installations may be a full pipe
(single) straight tube. feature all-welded metal surfaces, free of size smaller than the process piping.
Bent-tube meters offer accuracy and any crevices or synthetic materials that As a result, the flowmeter can create a
turndown benefits. In the bent-tube can absorb process chemicals. significant pressure drop in the system.
design, two bent tubes in the flowmeter While some bent-tube flowmeters It is up to each operating company to
are vibrated relative to one another. This drain well if they are oriented carefully, determine whether accuracy or pressure
vibration produces a sinusoidal motion others do not drain well no matter drop is most important. The smaller tube
along the length of both flow tubes. how they are installed. If drainability will be able to measure lower flows than
This motion is measured at the inlet is critical and the higher accuracy of a the larger tubes. The larger sensor will
and outlet of the sensor. The Coriolis bent-tube meter is also required, it is reduce piping system drain time.
effect produces a time delay between critical to work closely with the device’s
the motion at the inlet and outlet that is manufacturer. System drainability RULES OF THUMB
directly related to mass flow rate. and meter performance, or both, can Following are some rules of thumb for
Straight-tube meters are more rigid be compromised depending on the selecting Coriolis flowmeters in specific
than their bent counterparts, so they are orientation of the tube bends. For types of operations.
somewhat less sensitive. However, these example, low points can trap liquids and
devices offer improved drainability. In solids, while high points can trap gases. API Synthesis and Purification
the straight-tube design, the single flow Straight-tube Coriolis flowmeters There are numerous opportunities for
tube is vibrated relative to an external can be oriented in virtually any flow measurement devices during the
reference tube. The two pieces move in direction. When installed in vertical chemical synthesis phase of production.
opposite directions, and, as with the dual process piping, the flowmeter is fully Often, large quantities of raw materi-
tube device, the motion at the inlet is drainable; but the flow also should be als must be received from vendors and
compared to the motion at the outlet and up through a vertically installed meter. accounted for as they enter the chemical
the time delay between them is a direct If installed in horizontal process piping, synthesis process. There can be many dif-
ferent kinds of flow measurement devices water flow rate is erratic when the water empty and flashing. Generally, transient
scattered throughout the receiving phase. line must be completely drained. This flow refers to processes in which there
• Bent-tube Coriolis flowmeters are is the case whether vortex, magnetic or is continuous or intermittent mixture of
desirable wherever highly accurate, Coriolis technologies are used. However, gas, liquid and/or solids. In pharmaceuti-
reliable and rangeable mass flow or in such cases, maintaining two flow cal manufacturing, the high degree of
density measurement is needed. sensors that are kept full produces batch processing coupled with cleaning
• Straight-tube Coriolis flowmeters consistent results. practices often leads to situations where
are preferred when raw-material Coriolis flowmeters are more a flowmeter will start empty, be filled
contamination is a concern. Between expensive than most other flow and then emptied again by design. In
runs of the same material or between measurement technologies. However, the addition, poor hydraulic design in piping
runs of different materials it may be flowmeters’ additional cost is offset by can lead to gas entrapment and entrained
necessary to ensure that no cross-
contamination can occur.
Fewer flowmeters are involved The straight-tube Coriolis flowmeter, such as
in API purification processes, but the T series meter shown here, offers enhanced
Coriolis technology offers superior drainability. Photo Courtesy of Emerson Process
overall measurement accuracy, Management
repeatability, multivariable capability
and pharmaceutical-friendly materials
of construction. When accuracy is
secondary to drainability (about half of
the time) straight-tube meters should
be used. Otherwise, bent-tube meters
offer high performance and repeatability
characteristics.

Pharmaceutical Formulation the following factors: gas flow. Virtually any flow measuement
Formulation also offers opportunities for us- • Accuracy specifications from technology, including Coriolis flowmeters,
ing Coriolis flowmeters. In this case, cleanli- 0.5-100% of range, which allow can suffer unacceptable levels of error
ness is paramount, and the more accurate for setpoint optimization without when subjected to significant transient
bent-tube Coriolis flowmeter is a better replacing a flow sensor. flow. However, hardware and software-
choice. However, for fixed piping systems • Lack of any internal fabrication based solutions can reduce the impact of
that are cleaned in place, the straight-tube joints, a polished interior and, with transient flow on Coriolis flowmeters. In
type is preferred.Where disposable piping the straight-tube type, a design that processes where the transients are known,
systems are used, the bent-tube flow meter facilitates cleaning and draining. it is best to consult with the flowmeter
may be the better choice. • All-metal surfaces, which manufacturer.
eliminate the risk of leachables
High Purity Water and particulates breaking down About the Authors
Using a Coriolis flowmeter to measure synthetic materials of construction. Vince Salupo is an engineering consultant for
the flow rate on a simple distribution • Process containment Eli Lilly’s manufacturing facilities worldwide. He
loop is unwarranted when an adequate, • A direct mass flow rate or total. is leader of the instrumentation standards team
less expensive technology like a vortex Alternate technologies are generally that selects the flowmeter standards for Eli Lilly’s
flowmeter is available. However, Coriolis preferred when the flow rate to be global pharmaceutical manufacturing operations.
flowmeters can be used effectively in measured is kept within a small range or He can be reached at v.salupo@lilly.com.
high purity water and water-for-injection is volumetric and the process fluid is of a
(WFI) applications. To monitor the use consistent density. Franki Parson is the Life Sciences Industry
of high purity water, two straight-tube Manager for Emerson Process Management,
meters on a loop may replace a flowme- OVERCOMING TRANSIENT FLOW Micro Motion Division. She is a member of
ter at each point of use. This can save Recently, much attention has been AIChE, ISPE and is a participant on the ASME
considerable money and improve the paid to the difficulties associated with Bioprocessing Equipment Standard Task Group for
overall accuracy of total water usage. transient flow, which include two-phase Measurement Instrumentation. She can be reached
Users often complain that a totalized flow, entrained gas, slug flow, empty-fill- at franki.parson@emersonprocess.com

Reprinted with permission from Pharmaceutical Manufacturing, November/December 2006.