Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

05–668

DIAGNOSTICS – COMBINATION METER 057KO–04

THE AMBIENT TEMPERATURE DOES NOT DISPLAY

WIRING DIAGRAM

Combination Meter

3 26
IA6 C9 OUT SIDE TEMP+
B B
1 A7
Ambient
Temperature
2 Sensor
10 30
IA6 C9 OUT SIDE TEMP–
B–L B–L

I37764

2004 COROLLA (RM1037U)

Author: Date: 833


05–669
DIAGNOSTICS – COMBINATION METER

INSPECTION PROCEDURE
1 INSPECT OUTER AMBIENT TEMPERATURE SENSOR

(a) Remove cooler (ambient temp. sensor) thermistor.


(b) Measure resistance between terminals 1 and 2 of cooler
(ambient temp. sensor) thermistor connector at each tem-
perature.
1 2 Resistance:
at 0 C (0 F) : 9.097 – 9.701 kΩ
at 25 C (77 F) : 2.725 – 2.865 kΩ
HINT:
I30487 As the temperature increases, the resistance decreases.
Resistance:

Resistance (kΩ)

Temperature (C)

I30156

NG REPLACE OUTER AMBIENT TEMPERATURE


SENSOR

OK

2 CHECK HARNESS AND CONNECTOR

NG REPAIR OR REPLACE HARNESS OR


CONNECTOR

OK

CHECK AND REPLACE COMBINATION METER ASSY