Feature Deployment and Testing Guide

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 13

Feature Deployment and Testing Guide

Multi-band Support
Feature ID: ZWF21-00-023

Version: V3.11.10

ZTE CORPORATION
NO. 55, Hi-tech Road South, ShenZhen, P.R.China
Postcode: 518057
Tel: +86-755-26771900
Fax: +86-755-26770801
URL: http://ensupport.zte.com.cn
E-mail: support@zte.com.cn
LEGAL INFORMATION
Copyright © 2012 ZTE CORPORATION.
The contents of this document are protected by copyright laws and international treaties. Any reproduction or
distribution of this document or any portion of this document, in any form by any means, without the prior written
consent of ZTE CORPORATION is prohibited. Additionally, the contents of this document are protected by
contractual confidentiality obligations.
All company, brand and product names are trade or service marks, or registered trade or service marks, of ZTE
CORPORATION or of their respective owners.
This document is provided “as is”, and all express, implied, or statutory warranties, representations or conditions
are disclaimed, including without limitation any implied warranty of merchantability, fitness for a particular purpose,
title or non-infringement. ZTE CORPORATION and its licensors shall not be liable for damages resulting from the
use of or reliance on the information contained herein.
ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications
covering the subject matter of this document. Except as expressly provided in any written license between ZTE
CORPORATION and its licensee, the user of this document shall not acquire any license to the subject matter
herein.
ZTE CORPORATION reserves the right to upgrade or make technical change to this product without further notice.
Users may visit ZTE technical support website http://ensupport.zte.com.cn to inquire related information.
The ultimate right to interpret this product resides in ZTE CORPORATION.

Revision History

Revision No. Revision Date Revision Reason

R1.0 2012-08-09 First edition

Serial Number: SJ-20120802112720-001

Publishing Date: 2012-08-09 (R1.0)

SJ-20120802112720-001|2012-08-09 (R1.0) ZTE Proprietary and Confidential


Contents
Chapter 1 Functional Description ............................................................. 1-1
Chapter 2 Preparations .............................................................................. 2-1
Chapter 3 Data Configuration.................................................................... 3-1
Chapter 4 Testing ....................................................................................... 4-1
4.1 Test Purpose...................................................................................................... 4-1
4.2 Steps for Test..................................................................................................... 4-1
4.3 Expected Results ............................................................................................... 4-2

Chapter 5 Counter List............................................................................... 5-1

SJ-20120802112720-001|2012-08-09 (R1.0) ZTE Proprietary and Confidential


II

SJ-20120802112720-001|2012-08-09 (R1.0) ZTE Proprietary and Confidential


Chapter 1
Functional Description
Using module design, ZTE multiple frequency bands base stations solution can improve
multiplexing degree, shorten research and development cycle, reduce research and
development cost, and bring forth more benefit to our customers. Its principles of
implementation are described as follows:

1. The system architecture is designed based on the multi-band requirement, where the
RF module is replaced according to the corresponding bands.
2. For different bands, the RF module is configured by changing Transceiver Unit,
Duplexer Unit and PA unit corresponding to these bands. These units are also
designed on the same platform, in the same architecture on based the multi-band
requirement.
3. Based on the existing software platform, related software can realize base station
function at multiple frequency band by changing its frequency configuration.
3GPP defines 10 frequency bands in the UMTS system. For details, see the following
table.

Operation Band UL Frequencies DL Frequencies

UE transmit, Node B receive UE receive, Node B transmit

I 1920 - 1980 MHz 2110 - 2170 MHz

II 1850 - 1910 MHz 1930 - 1990 MHz

III 1710 - 1785 MHz 1805 - 1880 MHz

IV 1710 - 1755 MHz 2110 - 2155 MHz

V 824 - 849 MHz 869 - 894 MHz

VI 830 - 840 MHz 875 - 885 MHz

VII 2500 - 2570 MHz 2620 - 2690 MHz

VIII 880 - 915 MHz 925 - 960 MHz

IX 1749.9 - 1784.9 MHz 1844.9 - 1879.9 MHz

X 1710 - 1770 MHz 2100 - 2170 MHz

The multi-band series of base station is an important part of ZTE series of base station.
Besides band I(2100 MHz), band II(1900 MHz), band III(1800 MHz), band IV(AWS), band
V(850 MHz), band VIII(900 MHz) are supported also. In addition, customized band shall
be supported to satisfy customer requirements.

1-1

SJ-20120802112720-001|2012-08-09 (R1.0) ZTE Proprietary and Confidential


Feature Deployment and Testing Guide Feature ID: ZWF21-00-023

This page intentionally left blank.

1-2

SJ-20120802112720-001|2012-08-09 (R1.0) ZTE Proprietary and Confidential


Chapter 2
Preparations
License
N/A

Hardware Requirement

NE Requirement

RNC √

NodeB Require RRUs supporting different bands

Software Requirement

NE Involved Version Requirement

UE YES UMTS FDD Number: 1


Category: Any
Release: Any, supports
both U Band VIII and
Band I

NodeB YES V4.11.10.14 None

RNC YES V3.11.10.11 ZTE equipment

MSCS YES ZTE equipment

MGW YES ZTE equipment

SGSN NO ZTE equipment

GGSN NO

HLR NO

Topology
Topology is shown in Figure 2-1.

2-1

SJ-20120802112720-001|2012-08-09 (R1.0) ZTE Proprietary and Confidential


Feature Deployment and Testing Guide Feature ID: ZWF21-00-023

Figure 2-1 Topology

2-2

SJ-20120802112720-001|2012-08-09 (R1.0) ZTE Proprietary and Confidential


Chapter 3
Data Configuration
SGSN/GGSN - ZTE
None

MSC/MGW - ZTE
None

HLR - ZTE
None

RNC
Parameters setting in RNC
RNC needs to configure several celss with different bands. These cells belong to the same
NodeB. This test guide just takes Band I and Band VIII for example. Configure cell 1 as a
Band I cell with DUARFCN of 3050, cell 2 as a Band VIII cell with DUARFCN of 10562.

Figure 3-1 Frequency Band Indicator: Band I / Band VIII

Path: View > Configuration Management > RNC Managed Element > RNC Radio
Resource Management > UTRAN Cell > UTRAN Cell xxx > Cell Setup Parameters
> Frequency Band Indicator

NodeB
RRU1(type: R8860 GU906 ) needs to configure a U900M cell while RRU2(type: R8840)
needs to configure a U2.1G cell.

3-1

SJ-20120802112720-001|2012-08-09 (R1.0) ZTE Proprietary and Confidential


Feature Deployment and Testing Guide Feature ID: ZWF21-00-023

This page intentionally left blank.

3-2

SJ-20120802112720-001|2012-08-09 (R1.0) ZTE Proprietary and Confidential


Chapter 4
Testing
Table of Contents
Test Purpose ..............................................................................................................4-1
Steps for Test .............................................................................................................4-1
Expected Results .......................................................................................................4-2

4.1 Test Purpose


The purpose of this test case is to verify whether the NodeB support multi-band using
module design.
Related documents:
ZTE UMTS Particular Radio Function Feature Guide

4.2 Steps for Test


1. UE1 registers in cell 1. Cell 1 belongs to RRU 1 (type: R8860 GU906). UE1 actives a
PS service in cell 1. The “rrcConnectionSetup“ message indicates cell 1’s frequency
UL is 2825 and DL is 3050, which belongs to Band VIII.

The “rrcConnectionSetupComplete“ message indicates the bands that UE1 supports.


We may see that it supports Band I and Band VIII.

4-1

SJ-20120802112720-001|2012-08-09 (R1.0) ZTE Proprietary and Confidential


Feature Deployment and Testing Guide Feature ID: ZWF21-00-023

The PS service procedure is the same as general PS downloading procedure, referring


to “ZWF21-02-004 PS Interactive Background RAB”
2. UE1 registers in cell 2. Cell 2 belongs to RRU 2(type: R8840). RRU2 and
RRU 1 belong to the same NodeB. UE1 actives a PS service in cell 2. The
“rrcConnectionSetup” message indicates cell 2’s frequency UL is 9612 and DL is
10562, which belongs to Band I.

3. Other basic services are normal in cell 1 and cell 2. Multi-band support function is
normal.

4.3 Expected Results


The NodeB works normally with any RRU of the specified working bands. While UE1 can
register in both cells 1 with band VIII and cell 2 with Band I, required services are normal.

4-2

SJ-20120802112720-001|2012-08-09 (R1.0) ZTE Proprietary and Confidential


Chapter 5
Counter List
Counter No. Description

C310170870 Number of Successful HSDPA RAB establishment


for PS domain, Background Class

C310170875 Number of Successful HSDPA RAB establishment


for PS domain, Background Class, UE hsdpa
category 13-14

C310210953 Total RAB PS connection set-up time

C310210960 Total PS HSDPA RAB connection set-up time

C310251490 Number Of RAB normal release for UTRAN


for HSDPA:UE HSDPA categories 13 - 14,
background

C310312120 RAB release number for Iu connection release


request by UTRAN for PS domain in cell, Ue
Request

5-1

SJ-20120802112720-001|2012-08-09 (R1.0) ZTE Proprietary and Confidential