Bonding Materials

CICO BOND EPO


Hi gh St r en gt h E po xy Bo n d in g A gen t

CICO BOND EPO is two component 100% Surface should be cleaned, dry and free
solid epoxy resin system comprising of from loose particles, oil, grease or other
Pack-A (Resin) and Pack-B (Hardener). It foreign materials. Deep contaminated
concrete or metal should be thoroughly
is mainly used to bond old to old concrete
cleaned by wire brush. Dust can be
or new concrete or mortar to old removed by compressed air.
concrete, glazed bricks, tiles. Mixing
 Stir the base and hardener separately. A
Pack –A (Base white in colour) suitable power driven mixer / stirrer are
Pack –B (Hardener black in colour) recommended for uniform mixing.
 Add Hardener Part (Pack-B) to the base
USES container and mix for 20-40 seconds or until
CICO BOND EPO provides a bond of far a homogeneous color is obtained.
better strength than the Bond/Tensile  Wait for 2-3 minutes for induction and to
strength of concrete itself, and suitable release entrapped air from the epoxy mix.
wherever structural bonding of new to Remix the mass again before apply it.
existing old concrete is carried out.
It is used as adhesive to bond old Important Note
concrete to new concrete, stone cladding, All packs are pre-weighed and ready for onsite
metal plates, etc. mixing. Do not use fraction of any PACK.
Always use whole packs for best results. Do
FEATURES not mix more than 4kg at a time. Mixing of
higher quantity will reduce the handling time
 Very high mechanical strength
considerably.
 Moderate pot life suitable summer as
well as winter season Application
 Thixotropic- ensures less sagging and Apply a thin layer of CICO BOND EPO with brush
positive contact with the substrates / squeegee to the freshly cleaned existing
 Excellent bond strength on dry as well surface. Place fresh concrete/mortar while it is
still ‘tacky’. If there is a delay to lay the concrete
as damp concrete surfaces.
and applied CICO BOND EPO lost its ‘tackiness’
 Supply in two different colors (Pack A then a second coat of CICO BOND EPO shall be
and Pack B) for easy identification and applied prior to placing the freshly mixed
ensure proper mixing. concrete or mortar.
 No solvent is used therefore no harm
to the environment. Important Note:
While application, the substrate temperature
 Pre-measured packs to avoid wrong
should be at least 8⁰C but not above 40ᴼC.
mixing ratio at site.
Curing
METHOD OF USE
Surface Preparation Good concrete practice should be followed for
curing of freshly laid concrete.
Bonding Materials

TECHNICAL DATA
Appearance of Mixed
Grey coloured viscous PACKING
Material (Pack-A+B)
compound CICO BOND EPO is available in 0.5 Kg, 1 kg and 4
kg Kits.
Pot Life at 30˚C
30 minutes minimum
HANDLING PRECAUTION
Application Temperature
CICO BOND EPO should not be come in contact
Range +8ᴼC to +40ᴼC
with bare soft skin and eyes.
Wear gloves and safety glass during material
Tack Free Time at 30˚C
Not less than 2 hours handling to avoid direct contact. In case of
Non Volatile Matter, % contact with skin wash it with soap and water.
(w/w) 98 (minimum) In case contact with eyes splashes with plenty
of fresh clean water. If irritation persists, seek
Specific Gravity
1.2 ± 0.2
medical help.
Do not swallow. If swallowed accidentally, seek
Compressive Strength, kg/ medical help immediately. Do not induce
2
cm , 7days, at 30˚C 600 minimum
vomiting.
Do not smoke nearby the application area.
Shear Bond Strength,
In case of fire, use CO2 or foam based
2
kg/cm , 7 days, at 30˚C 35 (Concrete failure)
extinguisher.
a) On concrete (M-45
Pull off Bond Strength, SATORAGE
grade) : 30 minimum
2
kg/cm , 7days, at 30˚C Store in a cool dry place in the temperature
b) On Metal : 80
range from 5ᴼC to 30ᴼC in sealed condition. Keep
minimum
away from naked flame and direct Sun Light
2
250-500g /m per coat
depending upon the CLEANING
Coverage All tools shall be cleaned with suitable
surface porosity,
texture and working thinner like MEK, MIBK, and Xylene.
temperature. Important Note:
All CICO products are sold in the market after strict Quality Control in line of ISO
Flash Point 9001 and guaranteed against any manufacturing defect. Although the basic
Not applicable
formulation of Company’s products generally remains unchanged, production
refinements arising from continuing research and evaluation program may
18 Months from the occasionally result in marginal changes in properties. CICO aspires to ensure that
any recommendation, advice, test data, specification, method statement and
date of manufacturing other information given in this product datasheet is accurate and best of
company’s knowledge. Since, the company (CICO TECHNOLOGIES LTD) has no
when stored in sealed
control over the selection of its product, applicators, application methodology,
original packing in cool how and where it is applied, therefore, the company cannot accept any liability
Shelf Life directly or indirectly arising from the use of its product. It is important to any
and dry place at a customer; user or specifier satisfies him / herself that the product is suitable for
the intended purpose including health, safety and environmental aspect. Unless
temperature range of or otherwise agreed in writing, all products of the company are sold strictly
pursuant to the terms of our standard conditions of sale which are available
+5 to 30ᴼC and away upon request. All information and technical assistance is given without warranty
or guarantee and is subject to change without notice. All customers, users,
from direct sunlight
specifers should ensure that they examine the suitability of the product with
company’s latest product data sheet.

CICO TECHNOLOGIES LIMITED


st nd
CTL/10-13/02

Corp. Office: C-44/2, 1 & 2 Floor, Okhla Industrial Area,


Phase –II,New Delhi-110 020
Tel. No: 91-11-4050 9400, Fax: 91-11-4050 9413
E-Mail: cicotech@cicogroup.com
Web Site: www.cicogroup.com

You might also like