Professional Documents
Culture Documents
Catalogue - Data Logger and Sensors
Catalogue - Data Logger and Sensors
6 WEBDYNSUN GATEWAY
7 WEATHER SENSORS
IRRADIATION SENSOR , CLASS - II &
CLASS - I PYRANOMETERS
SENSORS
RAIN GAUGE
PRESSURE GAUGE
18 RF MODULE TRANSCIEVERS
DI TO MODBUS
ANALOG TO MODBUS
OPTIMISE THE FEEDBACK AND MONITORING OF YOUR FIELD SOURCE DATA
INDUSTRY
Monitoring and remote management of
SMART METERING industrial facilities
Collection and analysis of multi-fluid Gateways enabling industrial facilities, often he-
meters terogeneous and natively non-communicating,
to communicate, wether based on standard or
Concentrators and EndPoints dedicated to the
proprietary protocols, Bidirectional communi-
collection of data from all tyoes of meters. They
cation is thus made possible between these faci-
enable all the data available on the meter inter-
lities and the information system.
face (index, power, rate, etc.) to be transmitted
to a remote information system.
Examples:
Examples : - Industrial equipment and products: program-
- Industrial meter load curve mable logic controllers, machines, boilers, air-
- Multi-fluid meters: remote reading of water, conditionning systems, engines, etc...
electricity and gas meters, etc. - Development of products based on the client’s
specifications.
ENERGY CONTROL
Control of energy production and
TRANSPORT consumption
Rail, road and avionic transportation Gateways and EndPoints enabling all the data
from the environmental sensors (temperature,
hygrometry, irradiation, etc.) ad from the pro-
Recommended in constrained environments,
duction or consumption meters and central
these gateways permit an aggregation of inter-
equipment (inverters, air-conditioning line,
nal data concerning location, movement, ope-
etc.) to be aggregated on a single item of equip-
ration, etc., and bidirectional communication
ment. The objective is to analyse all the business
between the vehicle and the information sys-
and environment data of an energy system.
tem.
Examples :
Examples :
- Energy management: optimisation of produc-
- Railway ground-to-train communication
tion of renewable energies (photovoltaic, wind
- Vehicle fleet management
power, etc.)
- Building management: energy efficiency
VALUE CHAIN
Inverters
Modbus
equipments
Sensors
PulseRF
EndPoint 1
PulseRF
EndPoint 2
Ethernet
Wireless M-Bus 2G/3G/4G
PulseRF
EndPoint 3 Server User
PulseRF
EndPoint 4
GATEWAYS
WEBDYNSUN
The WebdynSun gateway is used to monitor and collect data from a solar plant
installation.The gateway brings together on a single unit all the indicators from
the inverters, the electric meters and the environmental sensors (sunshine in-
tensity, temperature, wind speed, etc.).
No. of Modbus devices than can be 200+ (included Modbus inverters, meters, sensors...
monitored in a single daisy chain etc)
length upto 800m
No. of proprietary protocol based Upto 100
inverters than can be monitored
6
GATEWAYS
WEBDYNModbus
The WebdynModbus gateway enables to manage or collect data from Mod-
bus equipments (slaves). On a single box, the gateway include a RTU Mod-
bus or TCP Modbus interface and an Ethernet and GPRS interfaces to com-
mmunicate with the information system.
TECHNICAL SPECIFICATIONS
Description WebdynModbus
Radio interfaces Modbus RTU (RS485) - Modbus TCP (ethernet)
IP network interfaces ethernet 10/100Mbits/s - GSM/GPRS
Power supply +12/24v
Operating temperature -5°C/+50°C
Storage temperature -20°C/+85°C
Power Consumption 3W maximum
REFERENCES
PRODUCTS ACCESSORIES
–– WG00513-A01: WebdynModbus Ethernet/2G Interfaces –– AC0103-00: Rail Din 24v power supply
–– WG00513-A02: WebdynModbus Ethernet/2G/ IP55 Interfaces –– AC0201-01: GPRS bi-bands deported antenna with 5m cable
–– AC0201-03: GPRS bi-bands deported antenna with 10m cable
–– AC0201-02: GPRS bi-bands deported antenna with 20m cable 7
SENSORS
PYRANOMETERS
LP PYRA
IRRADIATION SENSORS CLASS II & CLASS I PYRANOMETERS
Pyranometers are well suited for the measurement of incoming global solar
radiation (0.3µm / 3µm spectral range). LP PYRA shadow ring is designed to shiel
the instrument sensor from direct radiation; by that, an exact measurement of
the diffuse sky radiation is possible.
TECHNICAL SPECIFICATIONS
Description LP PYRA 02/LP PYRA 12 LP PYRA 03
Typical sensitivity 10 µV/(W/m²)
Impedance 33 Ω 45 Ω
Measuring range 0 2000 W/m²
Viewing field 2π Sr
Spectral field 305 nm 2800 nm W/m² (50%)
Operating temperature -40°C 80°C
Weight 0.90 Kg 0.45 Kg
A silicon solar sensor can be used as an irradiance sensor, because the short-cir-
cuit current is proportional to the irradiance.
The sensors are built with monocrystalline or polycrystalline laminated under
special solar glass with excellent UV resistance and long-term stability.
TECHNICAL SPECIFICATIONS
Description TYPE SOZ 03
Linear output signal 0 to 1500 W/m²
Accuracy ± 5%
Small drift < 0.3/year
Integrated signal amplifier 4 to 20 mA
with output signal Loop powered 2wire
Reference SOZ 03
9
SENSORS
SOLAR RADIATION
The Solar Ratiation Sensor, or solar pyrameter, measures global radiation, the
sim at the point of measurement of both the direct and diffuse components of
solar irradiance. The sensor’s transducer, which converts incident radiation to
electrical current, is a silicone photodiode with wide spectral response.
TECHNICAL SPECIFICATIONS
Description SOLAR RADIATION SENSOR WDS - RD - 300l
Operating temperature -40° to +65°C
Storage temparature -45° to +70°C
Spectral response 400 to 1100 nanometers
Temperature coefficient +0.12% per °C
Reference temperature 25°C
Weight 250 g
Range 0 to 1800 W/m²
TECHNICAL SPECIFICATIONS
Description Model WDS - MT - 04l
Measuring range 0 to 100°C
Accuracy ± 0.3°C
Sensors Temperature RTD Pt100Ω
Output 4-20mA
Supply voltage 12 to 26 VDC
11
SENSORS
WIND SPEED
The wind speed sensor is composed of a shell, three wind cups and a circuit
module. The whole sensor has a high strength, weather resistance, corrosion
resistance and water resistance, will be to ensure the long-term use of the ins-
trument, and the accuracy of the wind speed collection.
TECHNICAL SPECIFICATIONS
Description WIND SPEED SENSOR WDS - WS - 04l
Range 2 to 60m/sec
Output Pulse, 60Hz = 240 Km/hr
Dimensions 3 cup Dia 15cms
Cable lenght 2mts
Reference WDS - WS - 04l
12
SENSORS
WIND SPEED AND DIRECTION
ANEMOMETER - VANTAGE PRO2TM ACCESSORIES
Includes both wind speed and wind direction sensors. Rugged components
stand up to hurricane-force winds, yet are sensitive to a light breeze. Includes
sealed bearings for long life. The range and accuracy specifications have been
verified in wind-tunnel tests.
TECHNICAL SPECIFICATIONS
Description ANEMOMETER - VANTAGE PROTM
Range 0,5 to 89 m/s
Weight 1.322 Kg
TECHNICAL SPECIFICATIONS
Description Model WDS - AT - 04l
Measuring range 0 to 100°C
Accuracy ± 0.3°C
Sensors Temperature RTD Pt100Ω Class A
Output 4-20mA
Supply voltage 12 to 26 VDC
Housing Poly carbonate waterlight enclosure
Protection IP-65
14
SENSORS
AMBIENT TEMPERATURE
TEMPERATURE TRANSMITTER TxBlock-USB
TECHNICAL SPECIFICATIONS
Description TEMPERATURE TRANSMITTER TxBlock-USB
Loop powered output 4-20 mA
Power supply 8 to 35 Vdc
Accuracy ±0.1%
Temperature effect > 0.16% / 25°C
Working temperature -40 to +85°C
UBS for calibration and configuration
Reference TxBlock-USB
15
SENSORS
TEMPERATURE & HUMIDITY
TECHNICAL SPECIFICATIONS
Description Model RHT1000S
Measuring range 0 to 80°C
Accuracy @23°C ± 0.3°C
Sensors Humidity Thin-Film capacitor
Temperature RTD Pt100Ω
Temp compensation ±0.008%RH /°C
Output 4-20mA
Supply voltage 12 to 26 VDC
Housing ABS plastic waterlight enclosure
Protection IP-65 for transmitter
Reference RHT1000S
16
RAIN GAUGE
STAND ALONE RAIN COLLECTORS 6463 & 6465
The Rain Collector is designed to meet the guidelines of the World Meteorologi-
cal Organization. Rain enters the collector cone, passes through a debris-filtering
screen, and collects in one chamber of the tipping bucket. The shape is aerody-
namically designed to minimize rainfall catch reduction caused by high winds.
TECHNICAL SPECIFICATIONS
Description RAIN COLLECTORS 6463 & 6465
Accuracy Rain rates up to 100/hr : ±4% of total
Cable length 12m
Connector Modular RJ-11
Dimensions - rain collector 16.5cm x 24cm
Dimensions - collection area 214cm²
Weight - 6463 1kg
Weight - 6465 1.5kg
17
SENSOR PRESSURE GAUGE
TECHNICAL SPECIFICATIONS
Description PRESSURE SENSOR SB-100
Pressure range 15 to 115 kPa
Temperature range -40 to 125°C
Voltage output 0 to 5 V
Warm-up time 20 ms
Measurement uncertainty ± 1.5%
Measurement repeatibility < 0.1%
Weight 5g
Cable length 12 cm
Power use > 50 mW
Reference SB-100
18
20 RF MODULE TRANSCIEVERS
DI TO MODBUS
ANALOG TO MODBUS
GATEWAYS
WEBDYNRF WM-BUS
The WebdynRF platform is dedicated to wireless networks using the Wireless
M-Bus radio technology. Its main functions are the collection of data from
meters or sensors and the monitoring of Wireless M-Bus modules.
Converter RS485 signal to RF at 433MHz & from RF to RS485 compatible.
TECHNICAL SPECIFICATIONS
Description WebdynRF WM-Bus
Radio interfaces 868/169MHz
I/O interfaces 3 digital dry contact inputs - impulse and 1 digital output - relay
IP network interfaces ethernet 10/100Mbits/s - GSM/GPRS
Power supply +12/24v
Operating temperature -20°C/+70°C
Storage temperature -20°C/+85°C
Power Consumption 7W maximum
REFERENCES
PRODUCTS ACCESSORIES
–– WG0607-A01: Modem 2G - Wireless M-Bus 868MHZ –– AC0102-02: 12v external power supply
–– WG0607-A02: Modem 3G - Wireless M-Bus 868MHZ –– AC0103-00: Rail Din 24v power supply
–– WG0607-A11: Modem 2G - Wireless M-Bus 169MHZ –– AC0201-01: GPRS bi-bands deported antenna with 5m cable
–– WG0607-A12: Modem 3G - Wireless M-Bus 868MHZ –– AC0201-03: GPRS bi-bands deported antenna with 10m cable 20
–– AC0201-02: GPRS bi-bands deported antenna with 20m cable
–– AC0301-01: Rail Din and mural attachment kit
SIGNAL CONVERTER
4/8 CHANNEL DIN-Rail ANALOG INPUT MODULE MODBUS
OVER RS485 SERIAL INTERFACE
TECHNICAL SPECIFICATIONS
Description ANALOG INPUT MODULES MODBUS M100 4Al
Input 0-20A, 4-20 mA
Accuracy ±0.25% of reading
Zero offset user adjustable over full range for each channel
Baud rate settable 2400, 4800, 9600, 19200, 38400, 57600, 115200
TECHNICAL SPECIFICATIONS
Description DIGITAL INPUT MODULE
Input range +4V ~ +36V
Reference 16 Channels
22
WIRELESS DATA TRANSCEIVER
WIRELESS DATA TRANSCEIVER LONG RANGE DTU RS485
RS232
TECHNICAL SPECIFICATIONS
Description WIRELESS DATA TRANSCEIVER
Operating temperature -40 ~ +85°C
Weight 135 g
23
INDIA FRANCE
DLTA COMPLEX, RK KHANNA STADIUM 26 RUE DES GAUDINES
1, AFRICA AVENUE 78100
NEW DELHI 110 029 SAINT GERMAIN EN LAYE
GURDEEP.JUNEJA@WEBDYN.COM CONTACT@WEBDYN.COM