Contents
3.3 Installing the Host Software through the Site Maintenance Terminal System ............................................3-41
3.3.1 Overview of the Installation...............................................................................................................3-41
3.3.2 Installing the DTMU Software...........................................................................................................3-41
3.3.3 Installing the DTRU Software ...........................................................................................................3-50
3.3.4 Installing the DDPU Software ...........................................................................................................3-56
3.3.5 Installing the NFCB Software............................................................................................................3-56
3.3.6 Installing the DATU Software............................................................................................................3-56
3.4 Verifying Software Versions........................................................................................................................3-56
3.4.1 Verifying the Software Versions through the Remote Site Maintenance Terminal ............................3-57
3.4.2 Verifying the Software Versions through the Site Maintenance Terminal System .............................3-58
Figures
Figure 2-33 Completing the configuration for the BAM or GPRS host IP address..........................................2-30
Figure 2-34 User login .....................................................................................................................................2-30
Figure 3-21 Adding configuration item (with BSC version of G3BSC32V300R006C04) ..............................3-15
Title Description
1.1 Introduction to the Introduces the BTS3012AE software to be installed.
BTS3012AE Software
1.2 Brief Introduction to the Introduces the process for installing the BTS3012AE
Software Installation software.
MMI OMC
Server
Ab
is
Site Maintenance
BTS
Terminal System
MMI is
Ab BSC
Remote Site
Maintenance System
Site Maintenance BTS
Terminal System Hub
Collecting and handling the DATU internal alarms, which consists of:
− Internal power supply alarm
− Clock alarm
− EPLD read and write alarm
Controlling the 6-path feed switch and collecting the feed path alarms such as
undercurrent alarm, overcurrent alarm, and short-circuit alarm
Upgrading the board software online
Controlling the remote electrical tilt (RET) antenna
Performing power-on test and resetting
Upgrading the board software when the system is running
This manual describes the process for installing the software in a step-by-step manner. During the actual
installation, click Next or OK directly for the steps that are not mentioned in this manual.
Title Description
2.1 Installation Preparations Describes the preparations for installing the BTS3012AE
maintenance software.
2.2 Installation Procedures Introduces the procedure for installing the BTS3012AE
maintenance software.
2.3 Starting and Logging In to Describes how to start and log in to the O&M system.
the O&M System
2.4 Configuring Directory Describes how to configure a directory that saves the
software to be loaded.
For remote maintenance, you need to install the OMC system public module and then the O&M module.
For terminal maintenance, you need to install only the OMC system O&M module.
After the data preparation for the installation wizard is complete, the Welcome window is
displayed, as shown in Figure 2-2.
Step 5 Enter the company name, and keep the other values unchanged. Click Next.
The Choose Destination Location dialog box is displayed, as shown in Figure 2-6.
You can retain the default destination folder or click Browse to select another folder.
The name of the destination folder is a string of up to eight characters. If the string has more than eight
characters, the O&M module cannot be installed.
Contact the installation and maintenance personnel for the IP address. You can modify this IP address in
the configuration file after installing the OMC system.
The Report system information configuration dialog box is displayed, as shown in Figure
2-9. Keep the default setting of the IP address and port number. The IP address here is the IP
address of the OMC server. The port number is 4100.
Step 12 Click Next to start copying files. Figure 2-12 shows the copying progress.
After all the files are copied, the Setup Complete dialog box is displayed, as shown in
Figure 2-13.
After the data preparation for the installation wizard is complete, the Welcome window is
displayed, as shown in Figure 2-15.
Step 5 Enter your user name and company name. Keep the default serial number. Click Next.
The Choose Destination Location dialog box is displayed, as shown in Figure 2-19.
Step 6 Set the destination folder.
You can keep the default destination folder or click Browse to select another folder.
The name of the destination folder is a string of up to eight characters. If the string has more than eight
characters, the O&M module cannot be installed.
Huawei recommends that you keep the default destination folder or the same directory as that of the
OMC system public module.
To change the sub-components, click Change to display the Select Sub-components dialog
box as shown in Figure 2-21. Change the sub-components and then click Continue to return
to the Select Components dialog box as shown in Figure 2-20.
Figure 2-25 shows all the configuration information that is selected. If you find any mistake here, click
Back to correct it.
After the copying is complete, the Setup Complete dialog box is displayed, as shown in
Figure 2-29.
If the OMC common maintenance module and BSC maintenance module are present in the BAM before
the BTS maintenance module is installed, menu item OMC LocalWS is available.
To start and log in to the O&M system through the remote Site Maintenance System, do as
follows:
Step 1 Choose Start > Programs > Huawei GSM-OMC > OMC LocalWS.
The Configure BAM or GPRS Host IP dialog box is displayed, as shown in Figure 2-30.
Step 3 Enter the name (for example, base) and IP address (for example, 10.10.10.1), and click Add.
The Configure BAM or GPRS Host IP dialog box is refreshed, as shown in Figure 2-32.
Figure 2-33 Completing the configuration for the BAM or GPRS host IP address
You can also choose Start > User Management > Log in to log in to the system.
----End
If the BSC maintenance module is present in the BAM before the BTS maintenance software is installed,
menu item SITE Maintenance Terminal System is available.
To start and log in to the O&M system through the Site Maintenance Terminal System, choose
Start > Programs > Huawei GSM-OMC > SITE Maintenance Terminal System.
The Site Maintenance Terminal System dialog box is displayed, as shown in Figure 2-30.
BTS software installation through the remote Site Maintenance System requires the configuration for a
directory, but that through the Site Maintenance Terminal System does not require directory
configuration. For the BTS software installation through the Site Maintenance Terminal System, you can
directly start with section 3.3 "Installing the Host Software through the Site Maintenance Terminal
System."
Step 3 Select the version from the Directory drop-down list box, and click OK, which becomes
available after you select the version. Figure 2-37 shows that the OK button is available.
The HUAWEI GSM OMC LocalWS message box is displayed, as shown in Figure 2-38.
----End
Title Description
3.1 Installation Preparations Describes the preparations for installing the
BTS3012AE host software.
3.2 Installing the Host Software Describes the procedure for installing the host
through the Remote Site software through the remote Site Maintenance System.
Maintenance System
3.3 Installing the Host Software Describes the procedure for installing the host
through the Site Maintenance software through the Site Maintenance Terminal
Terminal System System.
3.4 Verifying Software Version Describes to the procedure for verifying the activated
software versions.
Install the software in the DTMU first, and then install the software in the DTRU and the other boards.
The downloading and activation of the software for the DTRU, DDPU, NFCB, and DATU are
independent of each other.
Step 6 Ensure that the running versions on the DTRU, DDPU, NFCB, and (or) DATU are the latest
versions.
----End
The software should be saved in the BAM. Disable the DTMU software auto activation switch before
loading the DTMU software. You can skip this procedure when establishing a new site. After all the
board software is upgraded, enable the DTMU software auto activation switch to avoid version rollback.
To install the software, load and activate the DTMU first, and then install the DTRU, DDPU,
NFCB, and DATU.
The Welcome to Data Auto Configuration System dialog box is displayed, as shown in
Figure 3-2.
Step 2 Select System Dynamic Configuration Work Mode, and then click OK.
The BSC Data Auto Configuration System window is displayed, as shown in Figure 3-3.
Step 4 Select the site type and then select a site. Click Next.
The Batch Modify Site Property dialog box is refreshed, as shown in Figure 3-6.
Step 8 Click the TMU Auto Activation Info tab, as shown in Figure 3-10.
----End
You can skip this procedure if the software index already exists.
Step 2 Select System Dynamic Configuration Work Mode, and then click OK.
The BSC Data Auto Configuration System window is displayed, as shown in Figure 3-17.
Step 3 Choose BSC > Dynamic Configuration without Command > BTS Software Index, as
shown in Figure 3-18.
In the BTS Software Configuration dialog box, you can click Add, Delete, or Modify to add, delete,
or modify the information. Double-click the item to fill in or check the detailed information.
In the Add Configuration Item dialog box, the Software Name, Active Software Version No. and
Version Time must be correct. If they are incorrect, the software loading fails.
The BTS Software Configuration dialog box is refreshed, as shown in Figure 3-22.
Add all the boards that require file index loading and configure them at a time.
Before loading the software through the remote Site Maintenance System, ensure that the Site
Maintenance Terminal System is disconnected for five seconds so that the it has no site management
right.
To load the software through the Remote Site Maintenance System, perform the following
steps:
Step 1 Choose Start > Task > BTS Maintenance as shown in Figure 3-26.
Step 2 Select the target site (for example, chquany) from the left pane, chquany from the middle
pane, and double-click Multi-site Software Load in the right pane, as shown in Figure 3-28.
The Software Load Procedure Indication dialog box is displayed, as shown in Figure 3-30.
In combined cabinets or cabinet groups, Board No. is null. The software for the DTMUs in all cabinets
is activated at a time.
The activation progress is displayed until the activation is complete, as shown in Figure 3-35.
The BTS initialization starts after you activate the DTMU software. The initialization temporarily
interrupts services. After all the board software is upgraded, enable the auto-activation function switch to
avoid version rollback. For details, refer to "Disabling the Auto-Activation Function Switch" in section
3.2.2 "Installing the DTMU Software."
----End
You can skip this procedure if the DTRU software index already exists.
Step 2 Select System Dynamic Configuration Work Mode, and click OK.
The BSC Data Auto Configuration System window is displayed, as shown in Figure 3-37.
Step 3 Choose BSC > Dynamic Configuration without Command > BTS Software Index, as
shown in Figure 3-38.
In the BTS Software Configuration dialog box, you can click Add, Delete, or Modify to add, delete,
or modify the information. Double-click the item to fill or check the detailed information.
The BTS software index configuration is complete. The Dynamic Configuration without
Command dialog box is displayed again.
Step 9 Click Next in the Dynamic Configuration without Command dialog box.
The Confirm dialog box is displayed, as shown in Figure 3-44.
Before loading the software through the Remote Site Maintenance System, ensure that the Site
Maintenance Terminal System is disconnected for five seconds so that it has no site management right.
To load the software through the remote Site Maintenance System, perform the following
steps:
Step 1 Choose Start > Task > BTS Maintenance.
The Site Maintenance System window is displayed, as shown in Figure 3-46.
Step 2 Select the target site (for example, chquany) from the left pane, chquany from the middle
pane, and double-click Multi-site Software Load in the right pane, as shown in Figure 3-47.
To activate the software on a board or several boards, specify the Board No., for example, 0, 1, or 0–5.
The default setting is null, which means activating all the boards of the same type.
----End
After all the board software is upgraded, enable the DTMU software auto-activation switch to avoid
version rollback. To enable the DTMU software auto-activation switch, refer to "Disabling the
Auto-Activation Function Switch" in section 3.2.2 "Installing the DTMU Software."
Step 1 Start the Site Maintenance Terminal System, as shown in Figure 3-55.
Step 3 Enter the user name and user password, and click OK.
Type Omc (case sensitive) in the User Name text box, and omc (case sensitive) in the User Password
textbox. You can also use the default password.
Step 4 In the Site Maintenance Terminal System window, double-click Site Management Right,
as shown in Figure 3-55.
The Site Management Right dialog box is displayed, as shown in Figure 3-57.
In the File Name text box, type the saving path of the software. You can click Browse to select a
different path.
The value range of Send Window Size is 1–49. The default value is 49.
A prompt "Software activation confirmed" is displayed on the status bar of the dialog box, as
shown in Figure 3-65.
----End
To activate a board or several boards, specify Board No., whose value range is 0, 1, or 0–5. The default
setting is null, which means the boards of one type are activated at a time.
----End
After activating the software through the Site Maintenance Terminal System, you need to
release the site management right.
The Get Site Software Version dialog box is displayed, as shown in Figure 3-74.
In the Get Site Software Version dialog box, you can obtain all the versions of the running software and
check whether the activated software versions are correct.
----End
----End