SPECIFICATIONS allows the batteries to act as a digits of the year.

backup power supply Example: 2013 is displayed as 13.


Temperature— in the event of a power outage. 6. Press the SET button, the
Range: 32.0 to 122.0 °F / 0.0 to 50.0 When using the AC power supply and
°C batteries month will ash.
Resolution: 0.1° together, the batteries will need to be 7. Press the or button to
Humidity— replaced
increment the
Range: 0.0 to 99.0% RH periodically to insure they have display to the correct value.
Resolution: 0.1%
Dew Point— suf cient power to 8. Press the SET button, the
Range: -4.0 to 158.0 °F / -20.0 to operate the meter during a power day number will ash.
70.0 °C outage (see the
Resolution: 0.1° “Battery Replacement” section). 9. Press the or button to
Display Update: 10 seconds increment the
Memory Card: Up to 2GB SD / Up to DISPLAY MESSAGES display to the correct value.
4GB SDHC 10. Press the SET button, the time-
Data Logging: 1 minute to 720 The following messages may appear of-day hours will
minute user alternating in ash.
selectable interval place of the time-of-day clock:
Sd Indicates that an SD memory card 11. Press the or button to
LED visual alarm indicator
is increment the
Ambient Temperature (TA) inserted; however, data logging is display to the correct value.
Battery status indicator turned off. 12. Press the SET button, the time-
rEc Indicates that an SD memory of-day minutes
Ambient Relative Humidity card is will ash.
Dew Point Temperature inserted and data logging is turned
on. 13. Press the or button to
Time-of-day clock (data logger FuLL Indicates that the SD memory increment the
messages will card is full display to the correct value.
also alternate here) and data logging if off (no records 14. Press the SET button, the display
may will return to
AC POWER SUPPLY/BATTERY be written to a full SD memory card) the current temperature/relative
POWER Err & Sd Indicates that the SD humidity display.
memory card was DISPLAYING °F OR °C
The meter may be powered the removed while data logging was With the meter turned on, to toggle
following ways: turned on, the display
Batteries only the meter is no longer recording data. between reading Fahrenheit or
Typical operating time when using Celsius, press and
the three (3) each SETTING TIME-OF-DAY/DATE hold the button for 3 seconds.
AA alkaline batteries only:
1. Turn the meter on by pressing the When using the data logging function,
Up to 1 year in display mode only, no
ON/OFF the
data logging,
button. temperature values recorded will
no alarms.
match the selected
Up to 1 month with data logging on at 2. Press and hold the SET and display unit (°F or °C).
a 1 minute
buttons
recording rate, with no alarms. Higher
simultaneously for 3 seconds to enter MINIMUM AND MAXIMUM
capacity
the MEMORY
memory cards require more power to
time-of-day/date setting mode (12H
operate;
or 24H will There are six points that are
therefore, larger cards will exhaust
ash on the display). automatically recorded
the batteries
into memory:
more rapidly. 3. Press the or button to • Minimum Ambient Temperature
AC power supply only
select 12 or 24 hour Achieved
If the AC power supply is being used
time format. • Maximum Ambient Temperature
without
4. Press the SET button, the Achieved
batteries, in the event of a power
• Minimum Ambient Relative Humidity
outage, the meter year will ash. Achieved
will turn off and data logging will stop.
5. Press the or button to • Maximum Ambient Relative
AC power supply and batteries
Humidity Achieved
together increment the
• Minimum Dew Point Temperature
Using the AC power supply and display to the correct value. This is
Achieved
batteries together the last 2
• Maximum Dew Point Temperature all of the LCD segments will appear release the SET button when “SET”
Achieved on the display for appears at
Minimum and maximum memories approximately 3 seconds indicating the bottom right side of the display in
are NOT that the minimum place of the
programmable. The minimum value and maximum memories have been time-of-day.
recorded into cleared. 2. The low alarm limit for the ambient
memory is the minimum reading The minimum and maximum temperature
achieved since the memories are also will appear. The alarm value
last time the memory was cleared. cleared when the meter is turned
The maximum off. and “Lo” will ash
value recorded into memory is the ALARMS on the display.
maximum reading 3. Press the or button to
achieved since the last time the Independent High/Low alarms may
increment the
memory was be set for all
display to the desired low alarm
cleared. The minimum and maximum readings (ambient temperature,
value.
memories are relative humidity and
4. Press the SET button. The high
maintained over the period since the dew point temperature). Temperature
alarm limit for
memory was alarm limits
the ambient temperature will appear.
last cleared. may be set in 0.1° increments.
The alarm
Relative humidity
VIEWING MINIMUM/MAXIMUM alarm limits may be set in 0.1% RH value and “Hi” will ash on
MEMORY increments. the display.
Each High/Low alarm limit may be
Press the MIN/MAX button, the independently 5. Press the or button to
display will show enabled/disabled allowing selecting increment the
“MIN” at the bottom left side of the of high alarm display to the desired high alarm
display indicating only, low alarm only, or both high and value.
that the minimum memory values are low alarm 6. Press the SET button. The low
being monitoring. alarm limit for the
displayed. SETTING HIGH/LOW ALARM ambient relative humidity will appear.
Press the MIN/MAX button a second LIMITS The alarm
time, the value and “Lo” will ash on
display will show “MAX” at the bottom While setting the High/Low alarm
left side of the limits, if no alarm the display.
display indicating that the maximum limit is desired for the value being 7. Press the or button to
memory values displayed, press
increment the
are being displayed. the MIN/MAX button, “--.-” will appear
display to the desired low alarm
Press the MIN/MAX button a third on the display
value.
time to return to indicating the alarm for the value is
8. Press the SET button. The high
the current temperature/humidity disabled.
alarm limit for
display (MIN/MAX Once a high and/or low alarm value
the ambient relative humidity will
will no longer appear on the display). has been set for
appear. The
a reading, the alarm will be enabled.
CLEARING THE appearing alarm value and “Hi” will ash
MINIMUM/MAXIMUM MEMORIES on the display.
to the left of the display value
indicates that an alarm 9. Press the or button to
Clearing the Minimum/Maximum
is enabled for that reading. Each
memories will increment the
readings High/Low
set both the minimum and maximum display to the desired high alarm
alarm limit may be independently
values for all value.
enabled/disabled
readings to the current display 10. Press the SET button. The low
allowing the selection of high alarm
readings. alarm limit for the
only, low alarm
The meter does not have to be in the dew point temperature will appear.
only, or both high and low alarm
Min/Max The alarm
memory display mode to clear the monitoring.
value and “Lo” will ash on
minimum/ appearing will indicate that either a
maximum memories. high alarm, low the display.
To clear the minimum and maximum alarm or both high and low alarms 11. Press the or button to
memories, are enabled for
press and hold the MIN/MAX button that reading. increment the
for 3 seconds, 1. Press and hold the SET button for display to the desired low alarm
3 seconds, value.
12. Press the SET button. The high button to increment the value to and no audible alarms will sound
alarm limit for while the alarm
the desired alarm
the dew point temperature will sound is turned off. The alarm sound
value. With an alarm value selected
appear. The alarm may only be
(“- -.-” no longer
value and “Hi” will be ashing turned back on by reaching and
appearing), the alarm will be enabled.
alarm condition and
on the display. Each High/Low alarm limit may be
pressing the SET button to turn the
independently
13. Press the or button to sound back on;
enabled/disabled allowing selecting
therefore, it is not recommended to
increment the of high alarm
turn off the
display to the desired high alarm only, low alarm only, or both high and
value. low alarm alarm sound. The ashing
14. Press the SET button. The data monitoring. and red LED alarm
logging rate will are not affected by this setting.
ash on the display (see the “ ALARM SOUNDING
DATA LOGGER
Adjusting Data With an alarm enabled, when a
Logger Recording Rate” section). reading being The built-in data logger is capable of
15. Press the SET button to return to measured is outside the alarm limit utilizing SD
the current that has been (2GB maximum) and SDHC (4GB
temperature/humidity display. set (equal to or lower than the low maximum)
alarm set point, or memory cards.
VIEWING HIGH/LOW ALARM equal to or greater than the high The sampling rate for the data logger
LIMITS alarm set point): may be set to
will ash on the display record readings from every 1 minute
Once alarm limits have been set, to every 720
follow the steps in next to the minutes in 1 minute increments. A 1
the “Setting High/Low Alarm Limits” measurement that is alarming minute interval
section to view (ambient will record 1440 readings/day. A 720
the values that have been set. If no temperature, ambient relative minute interval
changes are humidity or probe will record 2 readings/day.
desired, do not press the or temperature). will continue to
SD CARD SELECTION
buttons, simply ash next to the
press the SET button to move to the
measurement until the measured The supplied 256MB SD memory
next value.
value returns to card is ready for
an in-range condition. immediate use. When utilizing 3rd
DISABLE/ENABLE HIGH/LOW
The red LED will ash party SD/SDHC
ALARM LIMITS
cards, insure that they are formatted
continuously for the rst 10 as FAT16 or
Once alarm limits have been set,
seconds, and will then ash FAT32, NTFS format is not
follow the steps in
supported. SD cards up
the “Setting High/Low Alarm Limits” every 10 seconds to 2GB and SDHC cards up to 4GB
section to view
until the measured value returns to are supported.
the values that have been set. Press
an in-range Cards over 4GB and MMC/SDXC
the SET button
condition. cards are not
to cycle through the values that have
The audible alarm will sound supported.
been set.
continuously for the The supplied 256MB SD card is
An alarm limit may be disabled while
rst 10 seconds, and will then capable of storing
being displayed
5.9 million readings (over 10 years of
by pressing the MIN/MAX button, “- - sound every 10 readings at 1
.-” will appear
seconds until the measured value minute intervals).
on the display indicating the alarm for
returns to an Higher capacity memory cards
the value is
in-range condition. require more power
disabled. When an alarm value is
While alarming, the sound may be to operate; therefore, larger cards will
disabled, the
turned off by exhaust the
alarm value previously set will be
pressing the SET button (“Off” will batteries more rapidly (see the “AC
cleared.
appear on the Power Supply/
To enable an alarm that has been
display), it is not recommended to Battery Power” section).
disabled, while
turn off the
viewing the disabled alarm (“- -.-”),
alarm sound. This will turn off the
press the or alarm sound
INSERTING/REMOVING SD will appear. data logging must be turned back
MEMORY CARD 3. Press the SET button six (6) times on by using
to pass through the above procedure.
SD card door the alarm set-points, rAtE should If the SD card is removed while data
appear on the logging is
Lift up here to open SD card door display. turned on, Err and Sd will alternate
Proper SD memory card 4. The number ashing is the on the display
in place of the clock to indicate that
orientation for inserting data logger recording the meter is no
To remove the SD memory card:
interval (expressed in minutes). Press longer recording data. Insert the SD
1. Turn off data logging (see the
the or card to return to
“Turning On/Off
data logging.
Data Logging” section). button to increment the display to The following will cause data
2. Turn the meter off, by pressing the
the desired logging to stop/
ON/OFF button.
value. turn off:
3. Open the SD card door by lifting up
5. With the desired value on the • Turning the meter off
on the bottom
display, press the • Low battery power ( ), when using
of the door.
SET button to return to the current batteries only
4. Push the SD memory card until it
temperature/ • Power failure, when using the AC
“clicks”, then
humidity display. power supply only
release to allow the card to be
TURNING ON/OFF DATA LOGGING • Removing the SD memory card
ejected.
Prior to starting data logging: • Changing the time-of-day/date
To insert the SD memory card:
Make certain that the time-of-day and • Changing the data logger recording
1. Turn the meter off, by pressing the
date have rate
ON/OFF
been set properly (see the “Setting • Changing the High/Low alarm
button.
Time-of-Day/ settings
2. Open the SD card door by lifting up
Date” section). The recorded data will • Changing display from °F/°C, °C/°F
on the bottom
be time/ • Pressing the RESET button
of the door.
date stamped using the time-of- Once data logging has been
3. Make certain that the SD memory
day/date setting. stopped, it must be
card is oriented
Make certain that an SD/SDHC turned back on.
properly (see image) and insert by
memory card is
pushing the
inserted into the meter (see the DATA LOGGING FILE
card until it “clicks”.
“Inserting/ FORMAT/STRUCTURE
4. Close the SD card door by
Removing SD Memory Card”
snapping it shut.
section). With data logging turned on (see the
5. Turn the meter on by pressing the
Set the desired °F/°C display mode “Turning On/Off
ON/OFF button.
(see the Data Logging” section), the
6. Turn data logging on, if desired
“Displaying °F or °C” section).
(see the “Turning meter will write a le to
Set the desired data logger recording
On/Off Data Logging” section
rate (see the SD memory card. The le
the “Adjusting Data Logger Recording
ADJUSTING DATA LOGGER Rate” created is a standard
RECORDING RATE section). text (.TXT) le.
To toggle data logging On/Off, press
The sampling rate for the data logger and hold Once data logging has started,
may be set to the SET button for 6 seconds (each
record readings from every 1 minute the lename created
time this is
to every 720 is based on the start date (month and
performed, it will toggle from on/off
minutes in 1 minute increments. A 1 day number)
and from off/on):
minute interval and time.
OFf rEc indicates that the data
will record 1440 readings/day. A 720 logging function is off. Example: Start 11/28/2013 at
minute interval ON rEc indicates that the data
will record 2 readings/day. 16:48, will create a le
logging function is on.
1. Press and hold the SET button for with the name “11281648.TXT”.
While data logging is occurring, the
3 seconds, clock section will The maximum size per le is
release the SET button when “SET” alternate between displaying the time
appears at 30,000 records. During
and rEc.
the bottom right side of the display in If the meter is turned off, the data continuous data logging, once
place of the logging will
clock. the maximum le
also be turned off. When the meter
2. The low alarm limit for the ambient is turned on,
temperature
size has been reached, a new USB port on the computer. The Hook & Loop - Self adhesive hook
and loop
le is automatically rst time the USB mounting tape is supplied with the
created utilizing the same le card reader is plugged in to the meter. Peel off the
computer, drivers protective backing. Adhere one piece
naming method. A will automatically be installed to allow to the meter
le containing 30,000 records the card and the other to any clean,
reader to function.
represents over 20 at surface.
4. Browse to the SD card and
days of minute by minute data. ALL OPERATION DIFFICULTIES
Depending on the select the le(s) If this meter does not function
selected data logger recording rate to view. properly for any
and the duration, 5. Open the le(s) in the reason, replace the batteries with
continuous data logging may new, high-quality
generate numerous desired program (Word®, alkaline batteries (see the “Battery
les containing data. Excel®, NotePad, WordPad, etc). Replacement”
To open from Excel®, example: section). Low battery power can
The le created is a xed occasionally cause
File Open All Files (*.*) locate
width data le that may and select the an number of “apparent”
be read utilizing any computer le Open Fixed Width operational dif culties.
application capable
Next place column Replacing the batteries with new
of reading “.TXT” les fresh batteries will
breaks at 10, 20, 27, 34, and 44
(Word®, Excel®, NotePad, solve most dif culties.
Finish
WordPad, etc).
The text le is structured as PLACEMENT/MOUNTING OPTIONS ERROR CODES
follows:
Bench Stand - The meter is supplied E02 Indicates that the value being
Header Column Position
with a bench measured is
DATE (YYYY-MM-DD)
stand that is a part of the back of the below the measurement range of the
................................... 1-10
meter. To meter
TIME (HH:MM:SS)
use the bench stand, locate the small (too low).
...................................... 12-20
opening at E03 Indicates that the value being
Tair (?)1 (ambient temperature)
the corners on the back of the meter. measured is
.................... 21-27
Place your above the measurement range of the
RH(%) (ambient relative humidity)
ngernail into the opening meter (too high).
................ 28-34
E04 Indicates that the temperature
DP (?)1 (external/probe temperature) and ip the stand out. To sensor has
............ 35-44
close the stand, simply snap it shut. been damaged.
1This will show either F or C depending on
the value that Wall Mount - Set a screw into the E11 Indicates that the humidity
was selected to be displayed on the meter wall at the location sensor has
when data desired. The head of the screw will been damaged.
logging was started. need to slip E32/E33 Indicates that the meter has
into the receptacle on the back of the been damaged.
READING THE DATA FILE(S) meter, do not
FROM THE SD BATTERY REPLACEMENT
set the screw ush to the
CARD
wall. Once the screw has An erratic display, faint display, no
1. Remove the SD memory card from been set properly, hang the meter in display, or
the meter place by sliding appearing on the display are all
(see the “Inserting/Removing SD the receptacle on the back of the indicators that the
Memory Card” meter over the batteries need replacement.
section). head of the screw. If the AC power supply is not being
2. Insert the SD memory card into the Magnet - A magnet is supplied with used when the
supplied USB the meter. Peel batteries are being replaced, the
SD card reader. (If the computer the protective paper off the adhesive meter will turn off
being used has tape on the once the batteries have been
a built-in SD card reader, the USB magnet. Press the magnet onto the removed. The meter
card reader is back of the and data logging will need to be
not required.) thermometer and mount on any metal turned back on once
3. Plug the USB SD card reader into surface. the batteries have been replaced.
an available
If the AC power supply is being used
when the
batteries are being replaced, the
meter will continue
to function without interruption.
Remove the battery cover located on
the back of the
meter. Remove the exhausted
batteries and replace
them with three (3) new AA alkaline
batteries. Make
certain to insert the new batteries
with the proper
polarity as indicated by the illustration
in the battery
compartment. Replace the battery
cover.