KG/ Series Product Information

Straight Gas
1.3 - 14.5 MMBtu

The ProFire K/Series straight gas burner is a forced draft packaged burner system. A backward curved impeller
mounted in a manufactured housing provides combustion air for various furnace pressures or high altitude
applications. The ProFire KG gas burners burn gas under a controlled gas/air pressure mix. Gas is emitted from
jets surrounding the air stream, producing a turbulent mixture which burns quietly and efficiently.

The ProFire K/Series is listed by Underwriters Laboratory. CSD-1, Gap, F.M., NFPA-85 and other regulatory agency
control options are available. Every burner is assembled, wired and tested at the factory.

STANDARD EQUIPMENT
► 3450 RPM Blower Motor
► Panel Signal Lights: Power On, Main Fuel, Ignition,
and Flame Failure
► Combustion Air Proving Switch
► Ignition Transformer
► 120/1/60 Control Circuit
► Safety Shutoff Valve(s) with 2 Gas Shutoff Cocks
► Gas-Electric Interrupted Pilot

OPTIONAL FEATURES
S = STANDARD PFKG-13 PFKG-54 PFKG-105
O = OPTIONAL PFKG-17 PFKG-34 PFKG-63 PFKG-125
N/A = NOT AVAILABLE
PFKG-21 PFKG-25 PFKG-30 PFKG-42 PFKG-84 PFKG-145

Flame Safeguard with U.V. Scanner S S S S S S

Low-High-Off Firing S S S S N/A N/A

Low-High-Low Firing O O O O N/A N/A

Full Modulation Firing O O O O S S

Butterfly Rate Control Valve S S S S S S

High & Low Gas Pressure Interlocks O S S S S S

CB - ProFire KG - 5/09 1
SPECIFICATIONS & DIMENSIONS
BLOWER GAS
BLOWER
BURNER FRAME GAS FURN. PRESS. BHP MOTOR PRESSURE
MOTOR
MODEL SIZE INPUT (MBH) (“W.C.) @ 80% EFF. VOLT/ REQUIRED
HP
PH 60 HZ. (“W.C.)
PFKG-13 1 1,250 0.75 30 1/2 115/1 3.9

PFKG-17 1 1,750 0.75 40 1/2 115/1 6.6

PFKG-21 1 2,093 0.75 50 3/4 115/1 10.1

PFKG-25 1 2,510 0.75 60 3/4 115/1 14.3

PFKG-30 2 2,930 1.5 70 3/4 115/1 13.1

PFKG-34 2 3,348 1.5 80 1 115/1 16.9

PFKG-42 2 4,185 1.5 100 2 208/230/460/3 12.9

PFKG-54 3 5,231 3.0 125 2 208/230/460/3 12.5

PFKG-63 3 6,278 3.0 150 3 208/230/460/3 17.1

PFKG-84 3 8,370 3.0 200 7 1/2 208/230/460/3 19.1

PFKG-105 4 10,460 4.0 250 5 208/230/460/3 19.8

PFKG-125 4 12,560 4.0 300 7 1/2 208/230/460/3 31.6

PFKG-145 4 14,650 4.0 350 10 208/230/460/3 42.2

NOTES:
1. Gas input based on natural gas at 1,000 Btu/cu.ft. and 0.60 gravity.
2. Gas pressure based on zero furnace pressure. For total pressure at manifold, add furnace pressure.
3. Oil input based on No. 2 oil at 140,000 Btu/gal.
4. Boiler overall efficiency of 80% estimated.
5. Blower wheel and motor HP is based on altitude up to 2,000 ft. above sea level. For higher altitude or 50 Hz. applications,
consult factory.
6. Firing at higher furnace pressures de-rates the burner by approximately 5% per 1/2” of additional pressure, consult factory.

STANDARD CONFIGURATION

BURNER B
A C D E F G H I J K L M N
MODEL Std.
PFKG-13 7 1/2 3 37 7/8 3 5/8 7 1/4 7 3/8 21 3/8 10 1/2 5 1/4 10 3/4 15 7/8 5 1/4 18 11 1/4
PFKG-17 7 1/2 3 37 7/8 3 5/8 7 1/4 7 3/8 21 3/8 10 1/2 5 1/4 10 3/4 15 7/8 5 1/4 18 11 1/4
PFKG-21 7 1/2 3 37 7/8 3 5/8 7 1/4 7 3/8 21 3/8 10 1/2 5 1/4 10 3/4 15 7/8 5 1/4 18 11 1/4
PFKG-25 7 1/2 3 37 7/8 3 5/8 7 1/4 7 3/8 21 3/8 10 1/2 5 1/4 10 3/4 15 7/8 5 1/4 18 11 1/4
PFKG-30 9 1/4 4 41 7/8 4 7 1/8 8 7/8 23 3/8 12 6 11 3/8 19 6 1/2 17 3/8 12 7/8
PFKG-34 9 1/4 4 41 7/8 4 7 1/8 8 7/8 23 3/8 12 6 11 3/8 19 6 1/2 17 3/8 12 7/8
PFKG-42 9 1/4 4 41 7/8 4 7 1/8 8 7/8 23 3/8 12 6 11 3/8 19 6 1/2 17 3/8 12 7/8
PFKG-54 10 3/4 4 48 3/4 3 3/4 7 3/4 10 7/8 27 5/8 14 1/2 7 1/4 12 7/8 23 1/2 8 16 3/8 16 1/4
PFKG-63 10 3/4 4 48 3/4 3 3/4 7 3/4 10 7/8 27 5/8 14 1/2 7 1/4 12 7/8 23 1/2 8 16 3/8 16 1/4
PFKG-84 10 3/4 4 48 3/4 3 3/4 7 3/4 10 7/8 27 5/8 14 1/2 7 1/4 12 7/8 23 1/2 8 16 3/8 16 1/4
PFKG-105 12 1/8 5 56 3/8 3 7/8 8 3/4 12 1/2 32 7/8 17 1/2 8 3/4 15 27 1/8 10 17 3/8 20
PFKG-125 12 1/8 5 56 3/8 3 7/8 8 3/4 12 1/2 32 7/8 17 1/2 8 3/4 15 27 1/8 10 17 3/8 20
PFKG-145 12 1/8 5 56 3/8 3 7/8 8 3/4 12 1/2 32 7/8 17 1/2 8 3/4 15 27 1/8 10 17 3/8 20

2 CB - ProFire KG - 5/09
KL/ Series Product Information
Straight Oil
1.3 - 14.5 MMBtu

The ProFire K/Series straight oil burner is a forced draft packaged burner system. A backward curved impeller
mounted in a manufactured housing provides combustion air for various furnace pressures or high altitude
applications. The ProFire KL oil burners incorporate a high pressure atomizing design using simplex or return
flow nozzles. A directly driven fuel oil pump is burner mounted on sizes 13 through 42. A consistent fuel/air
ratio is maintained regardless of firing rate.

The ProFire K/Series is listed by Underwriters Laboratory. CSD-1, Gap, F.M., NFPA-85 and other regulatory agency
control options are available. Every burner is assembled, wired and tested at the factory.

STANDARD EQUIPMENT
► 3450 RPM Blower Motor
► Panel Signal Lights: Power On, Main Fuel, Ignition,
and Flame Failure
► Combustion Air Proving Switch
► Ignition Transformer
► 120/1/60 Control Circuit

OPTIONAL FEATURES
S = STANDARD PFKL-13 PFKL-54 PFKL-105
O = OPTIONAL PFKL-17 PFKL-34 PFKL-63 PFKL-125
N/A = NOT AVAILABLE
PFKL-21 PFKL-25 PFKL-30 PFKL-42 PFKL-84 PFKL-145

Flame Safeguard with U.V. Scanner S S S S S S

Low-High-Off Firing S S S S N/A N/A

Low-High-Low Firing O O O O N/A N/A

Full Modulation Firing O O O O S S

Directly Driven Oil Pump Set S S S S N/A N/A

Separately Driven Remote Oil Pump Set O O O O S S

Simplex Oil Nozzle S S S S S N/A

Return Flow Oil Nozzle N/A N/A ¹O ¹O O S


¹ Standard if Full Modulation is chosen.

CB - ProFire KL - 5/09 1
SPECIFICATIONS & DIMENSIONS
REMOTE BLOWER
OIL
BURNER FRAME FURN. PRESS. BHP MOTOR MOTOR OIL MOTOR
INPUT
MODEL SIZE (“W.C.) @ 80% EFF. HP¹ HP² PUMP MOTOR VOLT/
(GPH)
HP³ PH 60 HZ.
PFKL-13 1 8.9 0.75 30 1/2 1/2 1/3 115/1

PFKL-17 1 12.5 0.75 40 1/2 1/2 1/3 115/1

PFKL-21 1 14.9 0.75 50 3/4 3/4 1/3 115/1

PFKL-25 1 17.9 0.75 60 3/4 3/4 1/3 115/1

PFKL-30 2 20.9 1.5 70 3/4 3/4 1/3 115/1

PFKL-34 2 23.9 1.5 80 1 1 1/2 115/1

PFKL-42 2 29.9 1.5 100 2 2 1/2 208/230/460/3

PFKL-54 3 37.4 3.0 125 2 - 3/4 208/230/460/3

PFKL-63 3 44.8 3.0 150 3 - 3/4 208/230/460/3

PFKL-84 3 59.8 3.0 200 7 1/2 - 1 208/230/460/3

PFKL-105 4 74.7 4.0 250 5 - 1 1/2 208/230/460/3

PFKL-125 4 89.7 4.0 300 7 1/2 - 1 1/2 208/230/460/3

PFKL-145 4 105.0 4.0 350 10 - 1 1/2 208/230/460/3

NOTES: MOTOR SELECTIONS:


1. Gas input based on natural gas at 1,000 Btu/cu.ft. and 0.60 gravity. ¹ Motor ratings for gas only and remote oil pump burners.
2. Gas pressure based on zero furnace pressure. For total pressure at manifold, add furnace pressure. ² Motor ratings for direct drive oil pump burners.
3. Oil input based on No. 2 oil at 140,000 Btu/gal. ³ Remote oil pump is optional for all frame size 1-2.
4. Boiler overall efficiency of 80% estimated. For frame size 3-4, a remote oil pump is standard.
5. Blower wheel and motor HP is based on altitude up to 2,000 ft. above sea level. For higher altitude or 50 Hz. applications,
consult factory.
6. Firing at higher furnace pressures de-rates the burner by approximately 5% per 1/2” of additional pressure, consult factory.

STANDARD CONFIGURATION

BURNER B
A C D E F G H I J K L M N
MODEL Std.
PFKL-13 7 1/2 3 37 7/8 3 5/8 7 1/4 7 3/8 21 3/8 10 1/2 5 1/4 10 3/4 15 7/8 5 1/4 18 11 1/4
PFKL-17 7 1/2 3 37 7/8 3 5/8 7 1/4 7 3/8 21 3/8 10 1/2 5 1/4 10 3/4 15 7/8 5 1/4 18 11 1/4
PFKL-21 7 1/2 3 37 7/8 3 5/8 7 1/4 7 3/8 21 3/8 10 1/2 5 1/4 10 3/4 15 7/8 5 1/4 18 11 1/4
PFKL-25 7 1/2 3 37 7/8 3 5/8 7 1/4 7 3/8 21 3/8 10 1/2 5 1/4 10 3/4 15 7/8 5 1/4 18 11 1/4
PFKL-30 9 1/4 4 41 7/8 4 7 1/8 8 7/8 23 3/8 12 6 11 3/8 19 6 1/2 17 3/8 12 7/8
PFKL-34 9 1/4 4 41 7/8 4 7 1/8 8 7/8 23 3/8 12 6 11 3/8 19 6 1/2 17 3/8 12 7/8
PFKL-42 9 1/4 4 41 7/8 4 7 1/8 8 7/8 23 3/8 12 6 11 3/8 19 6 1/2 17 3/8 12 7/8
PFKL-54 10 3/4 4 48 3/4 3 3/4 7 3/4 10 7/8 27 5/8 14 1/2 7 1/4 12 7/8 23 1/2 8 16 3/8 16 1/4
PFKL-63 10 3/4 4 48 3/4 3 3/4 7 3/4 10 7/8 27 5/8 14 1/2 7 1/4 12 7/8 23 1/2 8 16 3/8 16 1/4
PFKL-84 10 3/4 4 48 3/4 3 3/4 7 3/4 10 7/8 27 5/8 14 1/2 7 1/4 12 7/8 23 1/2 8 16 3/8 16 1/4
PFKL-105 12 1/8 5 56 3/8 3 7/8 8 3/4 12 1/2 32 7/8 17 1/2 8 3/4 15 27 1/8 10 17 3/8 20
PFKL-125 12 1/8 5 56 3/8 3 7/8 8 3/4 12 1/2 32 7/8 17 1/2 8 3/4 15 27 1/8 10 17 3/8 20
PFKL-145 12 1/8 5 56 3/8 3 7/8 8 3/4 12 1/2 32 7/8 17 1/2 8 3/4 15 27 1/8 10 17 3/8 20

2 CB - ProFire KL - 5/09
KLG/ Series Product Information
Combination Gas / Oil
1.3 - 14.5 MMBtu

The ProFire K/Series gas/oil combination burner is a forced draft packaged burner system. A backward curved
impeller mounted in a manufactured housing provides combustion air for various furnace pressures or high
altitude applications. The ProFire KLG comination gas/oil burners change from one fuel to the other by simply
flipping a switch. No burner modifications or re-adjustments are required when changing from one fuel to the
other.

The ProFire K/Series is listed by Underwriters Laboratory. CSD-1, Gap, F.M., NFPA-85 and other regulatory agency
control options are available. Every burner is assembled, wired and tested at the factory.
STANDARD EQUIPMENT
► 3450 RPM Blower Motor
► Panel Signal Lights: Power On, Main Fuel, Ignition,
and Flame Failure
► Fuel Changeover Switch
► Combustion Air Proving Switch
► Ignition Transformer
► 120/1/60 Control Circuit
► Safety Shutoff Valve(s) with 2 Gas Shutoff Cocks
► Gas-Electric Interrupted Pilot

OPTIONAL FEATURES
S = STANDARD PFKLG-13 PFKLG-54 PFKLG-105
O = OPTIONAL PFKLG-17 PFKLG-34 PFKLG-63 PFKLG-125
N/A = NOT AVAILABLE
PFKLG-21 PFKLG-25 PFKLG-30 PFKLG-42 PFKLG-84 PFKLG-145

Flame Safeguard with U.V. Scanner S S S S S S

Low-High-Off Firing S S S S N/A N/A

Low-High-Low Firing O O O O N/A N/A

Full Modulation Firing O O O O S S

Directly Driven Oil Pump Set S S S S N/A N/A

Separately Driven Remote Oil Pump Set O O O O S S

Butterfly Rate Control Valve S S S S S S

High & Low Gas Pressure Interlocks O S S S S S

Simplex Oil Nozzle S S S S S N/A

Return Flow Oil Nozzle N/A N/A ¹O ¹O O S

¹ Standard if Full Modulation is chosen.

CB - ProFire KLG - 5/09 1


SPECIFICATIONS & DIMENSIONS
REMOTE BLOWER GAS
GAS OIL FURN.
BURNER FRAME BHP MOTOR MOTOR OIL MOTOR PRESSURE
INPUT INPUT PRESS.
MODEL SIZE @ 80% EFF. HP¹ HP² PUMP MOTOR VOLT/ REQUIRED
(MBH) (GPH) (“W.C.)
HP³ PH 60 HZ. (“W.C.)
PFKLG-13 1 1,250 8.9 0.75 30 1/2 1/2 1/3 115/1 3.9

PFKLG-17 1 1,750 12.5 0.75 40 1/2 1/2 1/3 115/1 6.6

PFKLG-21 1 2,093 14.9 0.75 50 3/4 3/4 1/3 115/1 10.1

PFKLG-25 1 2,510 17.9 0.75 60 3/4 3/4 1/3 115/1 14.3

PFKLG-30 2 2,930 20.9 1.5 70 3/4 3/4 1/3 115/1 13.1

PFKLG-34 2 3,348 23.9 1.5 80 1 1 1/2 115/1 16.9

PFKLG-42 2 4,185 29.9 1.5 100 2 2 1/2 208/230/460/3 12.9

PFKLG-54 3 5,231 37.4 3.0 125 2 - 3/4 208/230/460/3 12.5

PFKLG-63 3 6,278 44.8 3.0 150 3 - 3/4 208/230/460/3 17.1

PFKLG-84 3 8,370 59.8 3.0 200 7 1/2 - 1 208/230/460/3 19.1

PFKLG-105 4 10,460 74.7 4.0 250 5 - 1 1/2 208/230/460/3 19.8

PFKLG-125 4 12,560 89.7 4.0 300 7 1/2 - 1 1/2 208/230/460/3 31.6

PFKLG-145 4 14,650 105.0 4.0 350 10 - 1 1/2 208/230/460/3 42.2

NOTES: MOTOR SELECTIONS:


1. Gas input based on natural gas at 1,000 Btu/cu.ft. and 0.60 gravity. ¹ Motor ratings for gas only and remote oil pump burners.
2. Gas pressure based on zero furnace pressure. For total pressure at manifold, add furnace pressure. ² Motor ratings for direct drive oil pump burners.
3. Oil input based on No. 2 oil at 140,000 Btu/gal. ³ Remote oil pump is optional for all frame size 1-2.
4. Boiler overall efficiency of 80% estimated. For frame size 3-4, a remote oil pump is standard.
5. Blower wheel and motor HP is based on altitude up to 2,000 ft. above sea level. For higher altitude or 50 Hz. applications,
consult factory.
6. Firing at higher furnace pressures de-rates the burner by approximately 5% per 1/2” of additional pressure, consult factory.

STANDARD CONFIGURATION

BURNER B
A C D E F G H I J K L M N
MODEL Std.
PFKLG-13 7 1/2 3 37 7/8 3 5/8 7 1/4 7 3/8 21 3/8 10 1/2 5 1/4 10 3/4 15 7/8 5 1/4 18 11 1/4
PFKLG-17 7 1/2 3 37 7/8 3 5/8 7 1/4 7 3/8 21 3/8 10 1/2 5 1/4 10 3/4 15 7/8 5 1/4 18 11 1/4
PFKLG-21 7 1/2 3 37 7/8 3 5/8 7 1/4 7 3/8 21 3/8 10 1/2 5 1/4 10 3/4 15 7/8 5 1/4 18 11 1/4
PFKLG-25 7 1/2 3 37 7/8 3 5/8 7 1/4 7 3/8 21 3/8 10 1/2 5 1/4 10 3/4 15 7/8 5 1/4 18 11 1/4
PFKLG-30 9 1/4 4 41 7/8 4 7 1/8 8 7/8 23 3/8 12 6 11 3/8 19 6 1/2 17 3/8 12 7/8
PFKLG-34 9 1/4 4 41 7/8 4 7 1/8 8 7/8 23 3/8 12 6 11 3/8 19 6 1/2 17 3/8 12 7/8
PFKLG-42 9 1/4 4 41 7/8 4 7 1/8 8 7/8 23 3/8 12 6 11 3/8 19 6 1/2 17 3/8 12 7/8
PFKLG-54 10 3/4 4 48 3/4 3 3/4 7 3/4 10 7/8 27 5/8 14 1/2 7 1/4 12 7/8 23 1/2 8 16 3/8 16 1/4
PFKLG-63 10 3/4 4 48 3/4 3 3/4 7 3/4 10 7/8 27 5/8 14 1/2 7 1/4 12 7/8 23 1/2 8 16 3/8 16 1/4
PFKLG-84 10 3/4 4 48 3/4 3 3/4 7 3/4 10 7/8 27 5/8 14 1/2 7 1/4 12 7/8 23 1/2 8 16 3/8 16 1/4
PFKLG-105 12 1/8 5 56 3/8 3 7/8 8 3/4 12 1/2 32 7/8 17 1/2 8 3/4 15 27 1/8 10 17 3/8 20
PFKLG-125 12 1/8 5 56 3/8 3 7/8 8 3/4 12 1/2 32 7/8 17 1/2 8 3/4 15 27 1/8 10 17 3/8 20
PFKLG-145 12 1/8 5 56 3/8 3 7/8 8 3/4 12 1/2 32 7/8 17 1/2 8 3/4 15 27 1/8 10 17 3/8 20

2 CB - ProFire KLG - 5/09

You might also like