Professional Documents
Culture Documents
Datasheet
Datasheet
Catalog ST 80 · 2006
Subject to change without prior notice | Dispo 09402 | KG 1105 25.0 S 424 EN 601140 | Printed in Germany | © Siemens AG 2005 | IWI: TSTE
s
of performance which in case of actual use do not always apply as described
Automation and Drives or which may change as a result of further development of the products.
Human Machine Interface An obligation to provide the respective characteristics shall only exist if expressly
agreed in the terms of contract. Availability and technical specifications are
Postfach 4848
subject to change without notice.
90327 NÜRNBERG
Germany All product designations may be trademarks or product names of Siemens AG
or supplier companies whose use by third parties for their own purposes
w w w. s i e m e n s .c o m/ a uto ma t i o n could violate the rights of the owners.
SIMATIC ST 70
Products for
Totally Integrated Automation
and Micro Automation
Order No.:
E86060-K4670-A111-A9-7600
SIMATIC ST 70
Products for News
Totally Integrated Automation
and Micro Automation
Order No.:
E86060-K4670-A151-A2-7600
Industrial Communication IK PI
Industrial Communication
for Automation and Drives
Order No.:
E86060-K6710-A101-B4-7600
Industrial Communication IK PI
Industrial Communication News
for Automation and Drives
Order No.:
E86060-K6710-A121-A1-7600
SITRAIN ITC
Training for Automation and
Industrial Solutions
Order No.:
Paper: E86060-K6850-A101-B5 (in German only)
CD-ROM: E86060-D6850-A100-C2-7400 1)
Order No.:
CD-ROM: E86060-D4001-A110-C4-7600
DVD: E86060-D4001-A510-C4-7600
A&D Mall
Internet:
www.siemens.com/automation/mall
1) Available in German and English.
For further information contact your
nearest Siemens branch office.
Trademarks
s
Appendix
8
Welcome to
Automation and Drives
worldwide.
potential.
ERP
Enterprise
Resource
Planning Ethernet
Production Material
MES Order Management
Management
Manufacturing
Execution Ethernet
Systems Production
Operations
Equipment
Management
Recording
SIMATIC
Sensors
Ethernet
Industrial
Industrial
Ethernet
Safety Integrated
PROCESS FIELD
PROFIBUS
PC-based Automation
AS-Interface
Building
Technology
SIMATIC PCS 7
Process Control
System
Field Instru-
mentation/
Analytics
HART
SIWAREX
Weighing PROFIBUS PA
SIMOCODE pro SIMATIC Technology
Motor Manage- Distributed Drive Systems/
ment System I/O SIMODRIVE SINAMICS SINAMICS SINAMICS
Process/production U
I
cos o
P
W
automation
£ 110 kV
Building
ment
PAY PERIOD ENDING
Distribution
automation
DATE
SUN MON TUE WED THUR FRI SAT SUN TOTAL
IN
OUT
Maintenance
IN
OUT
OVERTIME
task DATE
SUN MON TUE WED THUR FRI
TOTAL HOURS
OUT
IN
OUT
TOTAL HOURS
checkup central ON DATE
OFF
SUN MON TUE WED THUR FRI SAT SUN TOTAL
OUT
OFF OUT
CODES
REGULAR HOLIDAY OTHER
V=VACATION
H=HOLIDAY
S=SICK OVER THE HOURS
SICK VACATION
TIME & ONE-HALF
instabus EIB
The interface between the operator and the machine the And over wireless LAN or cell phone connections, you can use
Human Machine Interface, or HMI connects the world of portable Thin Clients such as laptops, organizers or WebPads.
automation with the individual requirements of the operator. The process, service or management information is then
Operator control and monitoring means total control of the available to the respective users. At the machine level, many
process, keeping machinery and plants operating smoothly, operator panels support remote operation, for example as a
availability and productivity. link between the automation level and the control desk, through
to service and diagnostics over the Web.
Making increasing complex systems easier and easier
An area of conflict. Processes are becoming more sophisticated
and the requirements on the functionality of machines and
plant are growing. The operator must monitor, control and
think about so many things all at once. The human machine
interface has to offer the operator the highest degree of
transparency. With every new HMI innovation, it is our intention
to make increasingly complex matters more and more simple.
We shape innovations in HMI technology and implement them
in solutions that are at the forefront of development.
Everything from a single source
With SIMATIC HMI, Siemens A&D has a complete spectrum of
innovative as well as attractively priced products and systems
for the wide range of different tasks of operator control and
monitoring, not to mention customized solutions: From operator
panels and visualization software for human-machine interface
systems at the machine to a SCADA system for a wide range
of different requirements in process visualization.
Well-equipped for integration in the world of automation
With their open, standardized interfaces in hardware and
software, SIMATIC HMI products can be integrated into the
production level, automation level and the management level
at any time. They can be connected to almost any PLC on the
market; the configuration and visualization software is multi-
lingual, even encompassing ideographic Asian languages so
there are no barriers to worldwide implementation.
Part of the corporate IT landscape
Whether it is used for business optimization, quality assurance
at the MES level (Manufacturing Execution System) or to provide
management data for the corporate managers (ERP Enterprise
Resource Planning): beyond the boundaries of the automated
process, SIMATIC HMI will become an integral component of
the corporate IT landscape.
Integrated into the World Wide Web
SIMATIC HMI turns the Web into the control desk within the
plant as well as in the global network. Using the WinCC/Web
Navigator, you can monitor and operate plants over the Internet
or the internal company intranet. Operator panels such as the
SIMATIC MP 370 Multi Panel can be integrated as rugged Thin
Clients that simultaneously provide a link between the
automation level and the control desk.
Process visualization
SIMATIC WinCC
The SCADA system for scaleable process visualization for every
requirement from the single-user system to the redundant
multi-user system as well as for plant monitoring and operation
over the Internet. WinCC is the ideal information hub for IT and
business integration, such as for integration in MES and ERP
Single-user PC
systems.
Process
SIMATIC Push Button Panels
Operator panels that can be connected to the bus for easy,
direct operation of the machine.
SIMATIC Micro Panels
Operator panels for small machines and especially for
SIMATIC S7-200. Push Button Panels Micro Panels
Operator control and
SIMATIC ProTool
Integrated, system-wide configuring software under Windows
for all SIMATIC HMI operator panels.
SIMATIC ProTool/Pro
Visualization software for PC-based operator control and
monitoring directly at the machine. They permit short response
times and safe process operation.
Siemens ST 80 · 2006
Operator Control and Monitoring Devices
Introduction
■ Overview ■ Benefits
Rugged and compact for use at machine level.
With IP65/NEMA 4 degree of protection on the front side, high
EMC and extreme vibration resistance, the SIMATIC Operator
2 Panels are ideally suited for the use at machine level in rough
industrial environments. Thanks to their compact design with a
shallow mounting depth, the stationary Operator Panels can be
fitted anywhere, even where only restricted space is available.
The extremely rugged and shock-proof housing with IP65 de-
gree of protection makes the Mobile Panels especially suitable
for industrial applications. Their low weight and ergonomic
design means that they are user-friendly and easy to operate.
One configuration software for everything
SIMATICProTool or SIMATIC WinCC flexible are tools for the uni-
form configuration of all SIMATIC Panels, as well as PC-based
systems with the visualization software ProTool/Pro Runtime or
WinCC flexible Runtime. Graded variants are available for every
task. The software permits simple and efficient configuration.
Programming experience is not required.
A finely graded range of HMI devices is available for local oper-
ator control and monitoring. These include Push Button Panels, Completed configurations can be reused within the family.
Micro Panels, Panels, Multi Panels, and even Mobile Panels. Component of Totally Integrated Automation
Push Button Panels Siemens provides the complete modular system of matched
Push Button Panels (PP) are the innovative alternative to conven- components for automation solutions from one source and – with
tionally wired operator keypads. Supplied pre-assembled and Totally Integrated Automation – one of the most successful auto-
ready for installation, the bus-compatible operator panels are mation concepts worldwide. SIMATIC ProTool and WinCC flexi-
the key to drastically reducing wiring times when compared with ble are integral components of this world. It offers crucial advan-
conventional methods. tages. Thanks to the uniformity in configuration/programming,
data management and communication, the engineering costs of
Micro Panels an automation solution are significantly reduced.
Designed specifically for applications with the SIMATIC S7-200 Open for a wide variety of automation systems
micro PLC, either with text display (TD) or pixel-graphics display,
as operator panels (OP) with membrane keyboard or touch Despite the consistent incorporation into the SIMATIC world, the
screen (TP). Panels are nevertheless open for connection to PLCs from many
different vendors. The standard delivery includes a comprehen-
Mobile Panels sive range of user-friendly drivers.
The portable operator panels facilitate operator control and Innovative operator control and monitoring
monitoring at the actual scene of the event with direct access
and visual contact to the process. They offer simple and secure Based on the Windows CE operating system, 70, 170, 270 and
hot-swapping and can be used flexibly on machines or systems. 370 Series Mobile Panels, Panels and Multi Panels permit inno-
vative operator control and monitoring combined with rugged-
Panels ness, stability and simplicity. Standard hardware and software
Text Panels TD17, OP3/7/17 interfaces provide more flexibility and openness to the office
as text displays (TD) for simple message display or as operator world, for example, the MMC/PC/CF card, USB, Ethernet,
panels (OP) for operator control and monitoring using a mem- PROFIBUS DP, Visual Basic scripts or customer-specific ActiveX
brane keyboard. controls.
Introduction
■ Configuration overview
ProTool configuring software WinCC flexible engineering software
TP-Designer ProTool/Lite ProTool ProTool/Pro Micro Compact Standard Advanced
Micro Panels
• OP 73micro • • • • 2
• TP 070 •
• TP 170micro • • • •
• TP 177micro • • • •
Mobile Panels
• Mobile Panel 177 • 1) • 1) • 1)
Text Panels
• TD17/OP3/OP7/OP17 • • •
Panels – 70 series
• OP 73 • • •
• OP 77A/B • • •
Panels – 170 series
• TP 170A/ TP/OP 170B/ • • • • • •
• TP 177A • • •
• TP/OP 177B • 1) • 1) • 1)
Panels – 270 series
• TP 270/ OP 270 • • • •
Multi Panels – 270 series
• MP 270B 6" • •
• MP 270B 10" • • • •
Multi Panels – 370 series
• MP 370 • • • •
• Possible
Introduction
■ Technological overview
Micro Panels Mobile Panels Panels
Text Panels 70 series 170 series 270 series
TD100C 1) Mobile Panel 177 TD17 OP 73 TP 170A TP 270
TD 200/TD 200C 1) OP3/OP7/OP17 OP 77A/B TP/OP 170B OP 270
2 OP 73micro
TP 070 1)
TP 177A
TP/OP 177B
TP 170micro
TP 177micro
Display TD100C/ 5.7" STN Text display OP 73: 5.7" STN 5.7" / 10.4" STN
TD 200/ TD 200C: 3“ LCD
Text display OP 77A/B:
OP 73micro: 4.5” LCD
3“ LCD
TP 070/
TP 170micro/
TP 177micro:
5,7" STN
• Colors TD100C/ 256 colors Monochrome Monochrome TP 170A/ TP 177A 256 colors
TD 200/ TD 200C/ OP 170B:
OP 73micro: 4 blue modes
Monochrome TP 170B:
TP 070/ 4 blue modes/
TP 170micro/ 16 colors
TP 177micro: TP/OP 177B:
4 blue modes 4 blue modes/
256 colors
Control elements
• Membrane keyboard • (TD 100C/ - • • • •
TD 200/
TD 200C/
OP 73micro)
• Touch screen • (TP 070/ - - - • •
TP 170micro/
TP 177micro)
• Membrane keyboard - • - - • (OP 177B only) -
and Touch
Interfaces/protocols
• Serial / MPI / PROFIBUS DP •/•/- • / • 10) / • 10) • / • / • 2) •/•/• •/•/• •/•/•
• USB / Ethernet -/- - / • 6) -/- • 4) / - • / • 8) • / optional
• MMC /CF / PC card slot -/-/- •/-/- -/-/- • 4) / - / - • / • 3)5) / - -/•/-
Memory TD 100C/TD 200/ 2,048 KB TD17/OP3/OP7: OP 73/OP 77A: TP 170A: 320 KB 2 MB
(available for user data) TD 200C/TP 070 128 KB 256 KB TP 177A
OP 73micro: OP17: OP 77B 512 KB
128 KB 256 KB 1,024 KB TP 170B/OP 170B:
TP 170micro/ 768 KB
TP 177micro: TP/OP 177B:
256 KB approx. 2 MB
Interface with PLC
• SIMATIC S7 / WinAC S7-200 only •/• •/• •/• •/• •/•
• SIMATIC S5 / 505 - - / •/• • 2) / • 2) • 7) / • 7) • 5) / • 5) •/•
• SINUMERIK / SIMOTION -/- •/• • 2) / - -/- • 3) / • 5) •/•
• Non-Siemens controllers - • • 2) • 7) • 5) •
Applications/options with ProTool
• ProAgent - - - - - •
• ThinClient/MP - - - - - -
• MS Pocket Internet Explorer - - - - - -
• WinAC MP - - - - - -
Applications/options with WinCC flexible
• ProAgent - - - - - •
• Sm@rtService - • 6) - - • 8) •
• Sm@rtAccess - • 6) - - • 8) •
• OPC server - - - - - -
• ThinClient/MP - - - - - -
• MS Pocket Internet Explorer - - - - - -
• WinAC MP - - - - - -
• available - not available
Introduction
2
Display 5.7" / 10.4" TFT 12.1" / 15.1" TFT
• Colors 256 colors 256 colors
Control elements
• Membrane keyboard • •
• Touch screen • •
• Membrane keyboard and Touch - -
Interfaces/protocols
• Serial / MPI / PROFIBUS DP •/•/• •/•/•
• USB / Ethernet •/• •/•
• MMC /CF / PC card slot -/•/• -/•/•
Memory 5 MB 12 MB
(available for user data)
Interface with PLC
• SIMATIC S7 / WinAC •/• •/•
• SIMATIC S5 / 505 •/• •/•
• SINUMERIK / SIMOTION •/• •/•
• Non-Siemens controllers • •
Applications/options with ProTool/Pro
• ProAgent • •
• ThinClient/MP • (MP 270B 10″) • (MP 370 12″ Touch, MP 370 15“ Touch)
• MS Pocket Internet Explorer • •
• WinAC MP - •
Applications/options with WinCC flexible
• ProAgent • •
• Sm@rtService • •
• Sm@rtAccess • •
• OPC server • •
• ThinClient/MP • (MP 270B 10″) • (MP 370 12″ Touch, MP 370 15“ Touch)
• MS Pocket Internet Explorer • •
• available
- not available
Introduction
• Status signals/fault signals TD 100C: 40 / – TD17: 999 / – TP 170A: 2,000 / 2,000 2,000 / 2,000 2,000 / 2,000
TD 200: 80 / – OP3: 499 / – 1,000 / –
TP 070: – / – OP7: 499 / 499 TP 170B/
OP17: 999 / 999 OP 170B:
1,000 / 1,000
• Message buffer – OP3: – TP 170A 5): – 512 512 1,024
(number of entries) TD17/OP7/OP17: TP/ OP 170B 5):
256 128
• Recipes – TD17/OP3: – TP 170A: – 300 300 500
OP7/OP17: 99 TP/OP 170B:
100
• Process diagrams TP 070: 20 TD17: – TP 170A: 50 300 300 300
OP3: 40 TP/ OP 170B:
OP7/OP17: 100
99
• Bar/curve diagrams • / – (TP 070 only) –/– • / •1) •/• •/• •/•
(pixel graphics)
• Variables TP 070: 50 TD17: 1,000 TP 170A: 500 2,048 2,048 2,048
OP3: 1,024 TP/OP 170B:
OP7/OP17: 1,000
2,048
• Archiving - - - • • •
• Visual Basic Scripts - - - • • •
• Online languages 1 3 5 1) 5 5 5
• Password protection • (TD 100C/ • • • • •
TD 200C only)
• Print functions - • 2) • 1) • • •
• PG functions
(STATUS/CONTROL)
- • 4) - • • •
with SIMATIC S5/S7
• available
- not available
1) Except TP 170A
2) Except TD17/OP3
3) The TP 070 is configured using TP-Designer and the TD200/TD200C
are configured with Micro/WIN
4) Except TD17
5) Non-retentive
Introduction
• available
- not available
1) Except TP 170A/TP 177A
2) OP 77B only
3) Non-retentive
4) TP/OP 177B only
■ Overview ■ Design
The push button panels impress customers with their compact
design:
• Factory-fitted with 8 short-stroke keys, that can be labeled as
required using insertable strips
2 • Smooth front that is easy to clean;
the front is resistant to various oils, greases and standard
detergents
• Long-life, multi-color, surface-lighting LEDs in all short-stroke
keys
• Additional digital inputs for flexible expansions
• Pre-perforated cutouts for additional standard 22.5 mm com-
ponents (pushbuttons, lamps, emergency stop pushbuttons,
key switches)
• Rear display with mini-keypad to display operating states and
in plain text for changing the default settings
• The PP7 is designed to match the OP7 and they can therefore
be mounted side by side
SIMATIC Push Button Panels are the innovative alternative • Low-maintenance because batteries are not required
to conventional operator panels for easy and direct control of • All parameters are located in a memory module that can easily
machines: be replaced
• Pre-fabricated and ready for operation;
simply connect to the control and all buttons and lamps are
ready for immediate use
■ Function
• LED color modes (e.g., red, green, orange, red-flashing,
• Connection to any type of control via a bus cable green-flashing, yellow-flashing)
(PROFIBUS DP as "standard slave" or MPI)
• Integrated flashing rate for LED
• Fitted with short-stroke keys, additional digital inputs and slots
for 22.5 mm standard components • Integrated diagnostic functions
• Integrated lamp and key test (also for additional digital inputs)
■ Benefits • Menu-assisted parameterization via rear display with miniature
keyboard
• Up to 90% time savings: Pushbuttons, switches and lamps
do not have to be fitted and wired individually • Short-stroke keys and digital inputs are also parameterizable
as switches
• Use of standard cables, for example, makes configuration and
startup easier • Parameterizable pulse stretching for short-stroke keys and
digital inputs
• No configuration tool required
• PROFIBUS DP standard slave
• Service-friendly thanks to rear display to indicate operating
states and messages in plain text, without programming
device
• Quick and easy machine operation thanks to multi-colored
indicator lights
• User-friendly labeling option for pushbuttons and lamps using
slide-in labels
• As the 22.5 mm standard elements can be connected directly
on the panel, no additional wiring and I/O modules are
required.
■ Application
The rugged PP7 Push Button Panel is designed for simple and
straightforward machine operation.
It can be used wherever HMI functions cannot be carried out
without keys and lamps, e.g. on control consoles for machines
and plants in the food and beverage industry where smooth
fronts are necessary to facilitate cleaning. Even in special me-
chanical equipment manufacture, the push button panels can
be used to easily set up standard operator panels that are then
amenable to fast, flexible and modular expansion. The key and
lamp functions can be changed later at any time without having
to modify the wiring.
108
Documentation (to be ordered separately)
204
204
Manual for PP7/PP17 1)
188
• German 6AV3 991-1CA00-0AA0
• English 6AV3 991-1CA00-0AB0
4
• French 6AV3 991-1CA00-0AC0 30
• Italian 6AV3 991-1CA00-0AD0
• Spanish 6AV3 991-1CA00-0AE0
G_ST80_XX_00061
Brief startup guide
for PP7, PP17-I, PP17-II
• German 6AV3 991-1CA00-1BA0
Panel cutout (W x H) in mm: 130 x 190
• English 6AV3 991-1CA00-1BB0
Accessories for supplementary ordering
PROFIBUS connecting cable 6XV1 830-1CH30
830-1T ■ More information
For connection of terminal unit,
pre-assembled with two sub D For further information, visit our website at
connectors, 9-pin, 3 m
Bus connector RS 485 6GK1 500-0EA02
with axial cable outlet (180°)
Service package 6AV3 678-3XC30
for PP7, PP17-I, PP17-II
Consisting of: http://www.siemens.com/panels
• 1 x PP7 gasket
• 1 x PP17-I/PP17-II gasket
Note
• 5 x tensioning clamps
Do you need a specific modification or option for the products
• PP7 plug-in terminal strip described here? Then look up "Customized products", where
• PP17-I/PP17-II plug-in terminal you will find information about additional sector-specific prod-
strips ucts that can be ordered as well as about options for customer-
specific modification and adaptation.
Note:
Commercially available printing film can be used as labeling
strips for the keyboard. Word templates are enclosed with the
manual on a diskette.
1) Incl. 3.5" diskette with GSD files/type files and Word templates
for labeling strips
A) Subject to export regulations AL: N and ECCN: EAR99H
■ Overview ■ Design
The push button panels impress customers with their compact
design:
• Factory-fitted with short-stroke keys, that can be labeled as
required, also in color, using insertable strips
• Smooth front that is easy to clean; 2
The front is resistant to various oils, greases and standard
detergents
• Long-life, multi-color, wide-area LEDs in all short-stroke keys
• Additional digital inputs and outputs for flexible expansions
• Pre-perforated cutouts for additional standard 22.5 mm
components (push buttons, lamps, etc.) for PP17-I
• Rear display with keypad to display operating states in plain
text for changing the default settings
• Central enable input
• The PP17 is designed to match the OP17 and they can there-
fore be mounted together
• Low-maintenance because batteries are not required
SIMATIC Push Button Panels are the innovative alternative • All parameters are located in a memory module that can easily
to conventional operator panels for easy and direct control of be replaced
machines:
• Pre-fabricated and ready for operation;
simply connect to the control and all buttons and lamps are ■ Function
ready for immediate use • LED color modes (e.g., red, green, orange, red-flashing,
• Connection to any type of control via a bus cable green-flashing, yellow-flashing)
(PROFIBUS DP as "standard slave" or MPI) • Integrated flashing frequency for digital outputs and LED
• PP17-I: • Integrated diagnostic functions
Fitted with short-stroke keys, additional digital inputs and • Integrated lamp and key test (also for additional digital inputs
outputs and slots for 22.5 mm standard elements 24 V inputs and outputs)
PP17-II:
Fitted with short-stroke keys, additional digital inputs and • Menu-assisted parameterization via rear display with miniature
outputs and much more keyboard
• Short-stroke keys and digital inputs are also parameterizable
as switches
■ Benefits • Parameterizable pulse stretching for short-stroke keys and
• Up to 90% time savings: Pushbuttons, switches and lamps do digital inputs (max. 1000 ms)
not have to be fitted and wired individually
• PROFIBUS DP standard slave
• Use of standard cables, for example, makes configuration and
startup easier
• No configuration tool required
• Service-friendly thanks to rear display to indicate operating
states and messages in plain text, without programming
device
• Quick and easy machine operation thanks to multi-colored
indicator lights
• User-friendly labeling option for pushbuttons and lamps using
slide-in labels
• As the 22.5 mm standard elements can be connected directly
on the panel, no additional wiring and I/O modules are re-
quired.
■ Application
The rugged PP17 Push Button Panels are designed for easy and
straight-forward operation of the machine.
They can be used wherever keys and lamps are essential com-
ponents in a human-machine interface. In the food processing
industry, for example, on machines and systems on which
smooth fronts are required for easier cleaning. Even in special
mechanical equipment manufacture, the push button panels
can be used to easily set up standard operator panels that are
then amenable to fast, flexible and modular expansion. The key
and lamp functions can be changed later at any time without
having to modify the wiring.
(e.g., Allen Bradley, etc.) • Short-stroke keys (on-off operat.) 1,500,000 1,500,000
Digital outputs
System interfaces • Total power 12 W 12 W
PLC SIMATIC PP171) • Additional digital outputs 16 16
• In groups of 4 4
Target hardware (PROTOCOL) Connected via
(connector/physics) • Aggregate current per group, 500 mA 500 mA
max.
SIMATIC S7/SIMATIC WinAC (MPI as master) 2)
• Short-circuit protection Yes Yes
using MPI interface with Bus connector, connecting • LEDs (ON period) 100 100
S7-200/-300/-400/ cable and MPI network
WinAC Software/Slot PLC (see Catalog ST 70/IK PI) Functionality
(9-pin socket/RS 485),3) 4) • Short-stroke keys/digital inputs Yes Yes
SIMATIC S5/S7 (PROFIBUS DP as standard slave) as pushbutton or switch
• Integrated flashing rate for LEDs 0.5 Hz 0.5 Hz
using PROFIBUS with max. 1 x PROFIBUS 5)
S7-200 (CPU 215-DP) (see Catalog ST 70/IK PI) • Integrated flashing rate for 0.5 Hz or 2 Hz 0.5 Hz or 2 Hz
on MPI protocol digital outputs
S7-300/-400 • Pushbutton and lamp test Yes Yes
with integrated PROFIBUS interface • Max. 1000 ms 1000 ms
S7-300 with CP 342-5
• Enabling input Yes Yes
S7-400 with CP 443-5
• Max. number of slots for 22.5 mm 12 0
using PROFIBUS DP with PROFIBUS 5) standard elements
S5-95U/PROFIBUS DP master (see Catalog ST 70/IK PI)
(6ES5 095-8ME02) Interfaces (some only as options)
S5-115U/-135U/-155U • Interfaces 1 x RS485 max. 1 x RS485 max.
with IM 308C/IM 308B 12 Mbit/s 12 Mbit/s
S5-115U/-135U/-155U
with CP 5430/CP 5431 Supply voltage
• Permissible range +18 V to +18 V to
Non-Siemens controllers (PROFIBUS DP master) +30 V DC +30 V DC
5)
using PROFIBUS DP PROFIBUS • Rated current 0.2 A 0.4 A
(see Catalog ST 70/IK PI)
Degree of protection
1) PP17 suitable up to 12 Mbit/s • Front IP65 IP65
2) Standard PG/PC MPI cable cannot be used • Rear IP20 IP20
3) S7-200 only via MPI (CPU 212 not possible)
Certification CE, FM Class I CE, FM Class I
4) S7-200 CPU 215-DP also possible on PROFIBUS DP interface (some only as options) Div. 2, UL, CSA Div. 2, UL, CSA
via MPI protocol
5) Bus connector: 6GK1 500-0EA02 Mechanical components/
dimensions
Note: • Front panel W x H (mm) 240 x 204 240 x 204
The standard PG/PC MPI cable (6ES7 901-0BF00-0AA0) • Mounting cutout/depth 226 x 190/53 226 x 190/53
cannot be used to connect a PP and a CPU. W x H x D (mm) depth of unit depth of unit
Ambient conditions
■ Technical specifications • Max. relative humidity (in %) 95% 95%
PP17-I PP17-II • Mounting position Vertical Vertical
• Max. permissible angle of +/- 35° +/- 35°
Operating mode inclination without external fan
• Control elements Membrane Membrane
Temperature
keyboard keyboard
• Operation (vertical installation) 0 to +55 °C 0 to +55 °C
• Operating options Keys Keys
• Operation 0 to +55 °C 0 to +55 °C
• Function keys, programmable 16 function 32 function
(max. angle of inclination)
keys, 16 with keys, 32 with
LEDs LEDs • Transportation and storage -20 to +70 °C -20 to +70 °C
• Membrane keyboard Yes Yes Functionality (under ProTool)
• Touch screen No No Protocols
• Numeric/alphanumeric input No/No No/No • Interface to PLC S5, S7-200, S7- S5, S7-200, S7-
• Number of keys 16 short-stroke 32 short-stroke (may only be an option) 300/400Win AC, 300/400Win AC,
keys keys SINUMERIK, SINUMERIK,
SIMOTION SIMOTION,
Type of output and other Allen Bradley
• LED colors Red, yellow, Red, yellow, non-Siemens (DF485),
green green drivers OMRON
(LINK/Multilink)
• LED color modes 3 3 and other non-
• LED Anzahl 16 32 Siemens drivers
1) Ohmic load
95
re-perforated cutouts for
204
204
188
additional components
PP17-II A 6AV3 688-3ED13-0AX0
• 32 x short-stroke keys
• 32 x surface lighting diodes 4
32
• 16 x DI terminals (24 V)
• 16 x DO terminals (24 V)
G_ST80_XX_00059
• 1 x enabling input
Documentation (to be ordered separately)
Manual for PP7/PP17 1)
Panel cutout (B x H) in mm: 226 x 190
• German 6AV3 991-1CA00-0AA0
• English 6AV3 991-1CA00-0AB0
PP17-I
• French 6AV3 991-1CA00-0AC0
• Italian 6AV3 991-1CA00-0AD0
Dimensions in mm
• Spanish 6AV3 991-1CA00-0AE0
Brief startup guide
for PP7, PP17-I, PP17-II
• German 6AV3 991-1CA00-1BA0
240
• English 6AV3 991-1CA00-1BB0 224 53
Accessories for supplementary ordering
PROFIBUS connecting cable 6XV1 830-1CH30
99
830-1T
204
204
188
1) Incl. 3.5" diskette with GSD files/type files and Word templates
for labeling strips
A) Subject to export regulations AL: N and ECCN: EAR99H
http://www.siemens.com/panels
Note:
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about additional sector-specific prod-
ucts that can be ordered as well as about options for customer-
specific modification and adaptation.
■ Overview ■ Function
The TD 100C permits:
• Display of message texts
up to 40 message texts (alarms) with max. 4 variables display
current operating states and can be optionally parameterized
2 to require acknowledgment and can be additionally protected
by a password. Also up to 32 statical alarms with up to 4 vari-
ables can be configured. System texts are stored in English,
German, French, Spanish and Italian in the unit. Various char-
acter sets can be selected, and messages can be additionally
saved in the simplified Chinese character set.
• Display and modification of process parameters:
process parameters are output on the display, and can be
modified using the input keys, e.g. for temperature settings or
modifications to speed.
• Setting of inputs and outputs:
a bit memory is assigned to each of the programmable function
keys. These can then be set during operation, e.g. during com-
missioning, testing and diagnostics. It is then possible e.g. to
control motors without having to install additional control ele-
• The low-cost text display for the S7-200 with customized ments in the system.
display • Additional functions and features:
• For HMI functions: e.g. processing of floating-point numbers, various data blocks
display of message texts, interventions in the control program, for operation of several TDs on one CPU, password protection
setting of inputs and outputs for integral SETUP menu and modified variables
• Direct connection to CPU interface • Activation of TD 100C editing mode by PLC:
• No separate power supply required Variables embedded in messages can be edited directly with-
out having to press the Enter key or to place the cursor at the
• No separate parameterization software required variable.
• Front design can be selected individually • Setting a PLC bit:
• Addressing and setting of contrast in supplied menu - Set bit:
When a function key is pressed, a bit is set in the PLC.
This must be reset by the user program.
■ Application - Momentary:
When a function key is pressed, a bit is set; when the key is
The TD 100C Text Display is the low-cost solution for the simple
released, the bit is deleted.
HMI tasks of SIMATIC S7-200. The ability to print the surface of
the device individually allows it to be optimally adapted to the • New character set (Greek, Latin2, Turkish) to support further
application environment. foreign languages.
It supports: Programming
• Display of message texts The configuration data of the TD 100C are saved in the CPU of
• Interventions in the control program, e.g. modification of set- the S7-200. The message text strings and configuration param-
points eters are created with the STEP 7 Micro/WIN V4 programming
software. Additional parameterization software is not required.
• Setting of inputs and outputs, e.g. for switching a motor on and
The Keypad Designer (a component of STEP 7-Micro/WIN V4) is
off
used to configure the operating front design.
Special data areas are reserved in the CPU of the S7-200 for
■ Design data exchange with the TD 100C. The TD 100C directly ac-
The TD 100C is simply connected to the PPI interface of the cesses the respectively required functions of the CPU via these
S7-200 using the connecting cable that is available as an acces- data areas. A separate TD wizard in STEP 7 Micro/WIN V4 sup-
sory. A separate power supply is not required. It is also possible ports user-friendly parameter assignment.
to connect several text displays to one S7-200.
The TD 100C features:
• Rugged plastics housing with IP65 degree of protection (front):
Increased watertightness due to absence of slots for labeling
strips.
• Mounting depth of 36 mm (up to 44 mm with fixing):
the TD 100C can be mounted without additional accessories in
control cabinets or operator panels, or used as a handheld
unit.
• Reflecting 4-line display.
• Integral interface for connection of cable.
• Individually designable user interface:
The control elements of the front of the device as well as the
design can be configured individually on a printable sheet.
The Keypad Designer (a component of STEP 7-Micro/WIN) is
used for configuration.
■ Overview ■ Function
The TD 200 permits:
• Display of message texts:
up to 80 message texts (alarms) with max. 6 variables display
current operating states and can be optionally parameterized
2 to require acknowledgment and can be additionally protected
by a password. Also up to 64 static alarms with up to 6 vari-
ables can be configured. System texts are stored in English,
German, French, Spanish and Italian in the unit. Various char-
acter sets can be selected, and messages can be additionally
saved in the simplified Chinese character set.
• Display and modification of process parameters:
process parameters are output on the display, and can be
modified using the input keys, e.g. for temperature settings or
modifications to speed.
• Setting of inputs and outputs:
a memory bit is assigned to each of the 8 programmable func-
tion keys. These can then be set during operation, e.g. during
commissioning, testing and diagnostics. It is then possible e.g.
to control motors without having to install additional control
• The user-friendly text display for the S7-200 elements in the system.
• For control and monitoring: • Additional functions and features:
Message text display, intervention in PLC program, setting of e.g. processing of floating-point numbers, symbols for bar
inputs and outputs graph display, various data blocks for operation of several
• Direct connection to CPU interface using supplied cable or TD 200 displays on one CPU, password protection for integral
incorporation into network (also via EM 277) SETUP menu and modified variables.
• No separate power supply required • Activation of TD 200 editing mode by PLC:
• No separate parameterization software required Variables embedded in messages can be edited directly with-
• Addressing and setting of contrast in supplied menu out having to press the Enter key or to place the cursor at the
variable.
• Setting a PLC bit:
■ Application - Set bit:
The TD 200 text display is the optimum solution for all HMI tasks When a function key is pressed, a bit is set in the PLC.
with SIMATIC S7-200. This must be reset by the user program.
- Momentary:
It supports: A bit is set when pressing a function key, and deleted again
• Display of message texts when the key is released.
• Operator actions in the control program, e.g., modification of • New character set (Greek, Latin2, Turkish) to support further
setpoints foreign languages.
• Setting of inputs and outputs, e.g., for switching a motor on and Programming
off
The configuration data of the TD 200 are saved in the CPU of the
S7-200. The message text strings and configuration parameters
■ Design are created with the STEP 7 Micro/WIN configuration software
The TD 200 is simply connected to the PPI interface of the of V4 and higher. Additional parameterization software is not re-
S7-200 using the cable supplied. A separate power supply is not quired.
required. It is also possible to connect several TD 200 displays Special data areas are reserved in the CPU of the S7-200 for
to one S7-200. data exchange with the TD 200. The TD 200 directly accesses
The TD 200 features: the respectively required functions of the CPU via these data
areas. A separate TD 200 wizard in STEP 7 Micro/WIN V4 and
• Rugged plastics housing with degree of protection IP65 (front): higher supports user-friendly parameter assignment.
Increased watertightness due to absence of slots for labeling
strips.
• Mounting depth 27 mm:
The TD 200 can be mounted without additional accessories in
control cabinets or operator panels, or used as a handheld
unit.
• Backlit LCD;
easy to read even under poor lighting conditions
• User-friendly layout of input keys,
some of which are programmable function keys
• Integrated interface for connection of cable
• Connection for optional power supply:
a power supply unit is required if the distance between the
TD 200 and S7-200 is more than 2.5 m. PROFIBUS bus cables
are then available instead of the connection cable.
• User-specific labeling strips:
It is necessary to remove the rear of the housing before fitting
the labeling strips. Therefore, please fit the strips before install-
ing the device.
■ Overview ■ Function
The TD 200C permits:
• Display of message texts:
up to 80 message texts (alarms) with max. 6 variables display
current operating states and can be optionally parameterized
2 to require acknowledgment and can be additionally protected
by a password. Also up to 64 static alarms with up to 6 vari-
ables can be configured. System texts are stored in English,
German, French, Spanish and Italian in the unit. Various char-
acter sets can be selected, and messages can be additionally
saved in the simplified Chinese character set.
• Display and modification of process parameters:
process parameters are output on the display, and can be
modified using the input keys, e.g. for temperature settings or
modifications to speed.
• Setting of inputs and outputs:
a bit memory is assigned to each of the programmable function
keys. These can then be set during operation, e.g. during com-
missioning, testing and diagnostics. It is then possible e.g. to
control motors without having to install additional control ele-
• The user-friendly text display for the S7-200 with customizable
ments in the system.
display
• For control and monitoring: • Additional functions and features:
Message text display, intervention in PLC program, setting of e.g. processing of floating-point numbers, symbols for bar-
inputs and outputs graph display, various data blocks for operation of several TDs
on one CPU, password protection for integral SETUP menu and
• Direct connection to CPU interface using supplied cable or modified variables.
incorporation into network (also via EM 277)
• Activation of TD 200 editing mode by PLC:
• No separate power supply required
Variables embedded in messages can be edited directly
• No separate parameterization software required without having to press the Enter key or to place the cursor at
• Frontpanel design can be individually selected the variable.
• Addressing and setting of contrast in supplied menu • Setting a PLC bit:
- Set bit:
■ Application When a function key is pressed, a bit is set in the PLC.
This must be reset by the user program.
The TD 200C text display is the optimum solution for all HMI - Momentary:
tasks with SIMATIC S7-200. Individual printing of the surface of A bit is set when pressing a function key, and deleted again
the device enables it to be perfectly matched to the application when the key is released.
environment.
• New character set (Greek, Latin2, Turkish) to support further
It supports: foreign languages.
• Display of message texts • Programming the S7-200 memory module.
• Operator actions in the control program, e.g., modification of • Selection of operating mode of the CPU (RUN/STOP).
setpoints
• Editing the V memory area.
• Setting of inputs and outputs, e.g., for switching a motor on
and off Programming
The configuration data of the TD 200C are saved in the CPU of
■ Design the S7-200. The message text strings and configuration param-
The TD 200C is simply connected to the PPI interface of the eters are created with the STEP 7 Micro/WIN V4 programming
S7-200 using the supplied connecting cable. A separate power software. Additional parameterization software is not required.
supply is not required. It is also possible to connect several The Keypad Designer (a component of STEP 7-Micro/WIN V4) is
TD 200C to one S7-200. used to configure the operating front design.
The TD 200 features: Special data areas are reserved in the CPU of the S7-200 for
• Rugged plastics housing with degree of protection IP65 (front): data exchange with the TD 200C. The TD 200C directly ac-
Increased watertightness due to absence of slots for labeling cesses the respectively required functions of the CPU via these
strips. data areas. A separate TD 200 wizard in STEP 7 Micro/WIN V4
• Mounting depth 27 mm: supports user-friendly parameter assignment.
The TD 200C can be mounted without additional accessories in
control cabinets or operator panels, or used as a handheld unit.
• Backlit LC display;
readable even under unfavorable lighting.
• Integrated interface for connection of cable.
• Connection for optional power supply:
A power supply unit is required if the distance between the
TD 200C and S7-200 is more than 2.5 m. PROFIBUS cables are
then available instead of the connection cable.
• Individually designable user interface:
The control elements of the front of the device as well as the
design can be configured individually on a printable sheet. The
Keypad Designer (a component of STEP 7-Micro/WIN) is used
for configuration.
■ Overview ■ Design
• 3" LCD, 160 x 48 pixels, monochrome
• 8 system keys, 4 freely configurable function keys
• Numeric and alphanumeric input using cursor control keys
2 • Compact design with small installation depth
• Rugged plastic housing
• The front is resistant to various oils, greases and standard
detergents
• Plug-in terminals for connecting a 24 V DC power supply
• RS 485 interface for connecting the MPI connecting cable or
the PPI adapter
■ Function
• Input/output fields
for displaying and changing process parameters
• Function keys
for direct triggering of functions and actions. Up to 16 functions
• Operator Panel for controlling and monitoring machines and can be configured simultaneously on function keys.
systems. • Graphics
• Graphics in a new dimension: small and smart can be used as icons instead of text to "label" function keys or
buttons. They can also be used as simple on-screen graphics.
• Pixel-graphics 3" LCD, monochrome In the configuration tool, a library is available containing an
• 8 system keys, 4 user-configurable function keys extensive range of graphics and a wide variety of objects.
• Specific to the SIMATIC S7-200: All editors with an OLE interface can be used as graphics
Communication with the controller takes place via the inte- editors (such as PaintShop, Designer or CorelDraw).
grated interface (point-to-point) • Predefined
• Connection to the controller via MPI or PROFIBUS DP cable for labeling function keys, process images and process values
in different font sizes
• Bars are used for the graphical display of dynamic values
■ Benefits • Language selection during runtime
• High-contrast display for good readability - 5 online languages, 32 configuration languages incl. Asian
• Large keys for high operational safety and Cyrillic character sets
• Simple handling and configuring • User administration (security) according to the requirements of
the various sectors
• Fast configuring and start-up - Authentication using password
- Service-friendly thanks to maintenance-free design
(no battery) and long service life of the backlighting • Signaling system
- Discrete alarms
• Graphics library is available complete with ready-to-use - Freely definable message classes (e.g., status/fault
display objects messages) for definition of acknowledgment response and
• Can be used worldwide: display of message events
- 32 languages can be configured (including Asiatic and - Message history
Cyrillic character sets) • Help texts
- Up to 5 languages are selectable online for process images, messages and variables
• Arithmetic functions
■ Application • Limit value monitoring
OP 73micro Operator Panels can be used wherever machines for reliable process control of inputs and outputs
and systems are controlled and monitored locally – in produc- • Indicator light
tion, process and building automation alike. They are used in all for machine and plant status indication
types of sectors and applications. • Scheduler for global function execution
The OP 73micro has been designed specifically for use with the • Template concept
SIMATIC S7-200. Creation of picture templates (picture elements configured in
the template appear in every image)
Compatibility
• Simple maintenance and configuration thanks to:
• Same mounting cutout as the OP3 and TD200 - Backup and restoration of configuration, operating system
and firmware on a PC using ProSave
- Configuration download serially via RS485
- Individual contrast settings
- No batteries are necessary
■ Dimension drawings
Dimensions in mm
154 28.5
67.7
84
■ Overview ■ Design
• 5.7” STN display, CCFL1) backlit, Bluemode (4 levels)
• Resistive analog Touch
• Compact design with small installation depth
2 • Rugged plastic housing
• The front is resistant to various oils, greases and standard
detergents
• A protective cover is available as an option to achieve NEMA 4
degree of protection as well as for additional protection from
dirt and scratching
• Numeric system keyboard for decimal, binary and hexa-
decimal number formats
• Plug-type terminals for connection of a 24 V DC power supply
(200 mA)
• RS 485 interface for connection of the MPI cable or the PPI
adaptor
1) Cold Cathode Fluorescence Lamps
■ Integration
The TP 070 can be connected to all SIMATIC S7-200 CPUs (ex-
cept CPU 212) using standard MPI bus cables or PROFIBUS DP
cables.
Note:
For further information, see "System interfaces"
■ Technical specifications
SIMATIC TP 070 SIMATIC TP 070
Display Ambient conditions
• Display type STN liquid crystal display (LCD) • Max. relative humidity (in %) 85%
• Size 5.7" • Mounting position
- Max. permissible angle of incli-
Vertical
+/- 35°
2
• Resolution (W x H in pixels) 320 x 240
nation without external fan
• Colors 4 shades of blue
• Temperature
• MTBF of background lighting approx. 50,000 hours - Operation (vertical installation) 0 to +50 °C
(at 25 °C)
- Operation (max. angle of inclina- 0 to +40 °C
Operating mode tion)
• Control elements Touch screen - Transportation and storage -20 to +60 °C
• Numeric/alphanumeric input Yes/No Configuring
Processor/HW • Configuration tool MicroWin
• Processor RISC 32 bits, 66 MHz Protocols
Operating systems Windows CE • Interface to PLC S7-200
(may only be an option)
Memory
Process images 30
• Type Flash/RAM
Picture elements
• Usable memory for project data 128 KB user memory/without
additional memory for options • Text objects 80 text elements
Interfaces (some only as options) 1 x RS485 max. 0.0192 Mbit/s • Number 80
Supply voltage • Fields per screen 20
• Permissible range +18 V to +30 V DC • Variables per screen 10
• Rated current 0.24 A • Graphics objects Bit maps, icons, background pic-
tures
Clock/type Software clock, without battery
backup • Alphanumeric fields 50
Degree of protection • Numeric fields 50
(some only as options) Variables 50
• Front IP65, NEMA 4; (when mounted) Fonts
• Rear IP20 • Language (keyboard fonts) US English
Certification and standards CE, FM Class I Div. 2, UL, CSA, Languages
(some only as options) cULus
• Online languages 1
Mechanical components/
dimensions • Project languages G/E/F/I/S
• Front panel W x H (mm) 212 x 156 • Character set Tahoma, all freely scalable
• Mounting cutout/depth W x H x D 198 x 142/45 mm depth of unit Transfer under ProTool
(mm) (upload/download)
• Weight 0.7 kg • Transfer of the configuration Serial
140
156
TP 070 Manual
• German 6AV6 591-1DC01-0AA0
• English 6AV6 591-1DC01-0AB0 42
• French 6AV6 591-1DC01-0AC0
• Italian 6AV6 591-1DC01-0AD0
G_ST80_XX_00065
• Spanish 6AV6 591-1DC01-0AE0
SIMATIC HMI C 6AV6 691-1SA01-0AX0
Manual Collection
Electronic documentation, Panel cutout (W x H) in mm: 198 x 142
on CD-ROM
5 languages (English, French,
German, Italian and Spanish);
comprising: all currently available
user manuals, product manuals ■ More information
and communication manuals for
SIMATIC HMI For further information, visit our website at
Accessories for supplementary ordering
Protective foil 6AV6 574-1AD00-4AX0
(pack of 10)
Protective cover 6AV6 574-1AE00-4AX0
(2 sets) http://www.siemens.com/panels
Service package 6AV6 574-1AA00-4AX0
comprising:
Note
• Gaskets Do you need a specific modification or option for the products
• 2 sets of labeling strips (for OPs) described here? Then look up "Customized products",
• 7 clamps where you will find information about additional sector-specific
products that can be ordered as well as about options for
• Clamp-type terminal strip customer-specific modification and adaptation.
(block of two)
PC/PPI Multimaster cable 1) 6ES7 901-3CB03-0XA0
for connection of the S7-200 to
serial PC/OP interface
PROFIBUS 830-1T 6XV1 830-1CH30
connecting cable
For connection of data terminal,
precut/preassembled with two
sub D connectors, 9-pin, 3 m
System interfaces See page 2/169
Connecting cables See page 2/180
■ Overview ■ Design
• STN display, CCFL1) backlit, Bluemode
• Resistive analog Touch
• Compact design with shallow installation depth
• Rugged plastic housing
• The front is resistant to various oils, greases and standard
2
detergents
• A protective cover is available as an option for achieving the
NEMA 4 degree of protection and as additional protection
against fouling and scratching
• Numeric "on-screen“ system keyboard for decimal, binary and
hexadecimal numeric formats
• Clamp-type terminals for connection of a power supply
• An interface for connecting the MPI connecting cable to the
PLC or configuration computer via a PPI adapter is integrated.
■ Technical specifications
SIMATIC TP 170micro SIMATIC TP 170micro
Display Configuring
• Display type STN liquid crystal display (LCD) • Configuration tool WinCC flexible
• Size 5.7" Protocols
• Resolution (W x H in pixels) 320 x 240 • Interface to control S7-200
• Colors 4 shades of blue (may only be an option)
• MTBF of background lighting approx. 50,000 hours Signaling system
(at 25 °C)
• Number of messages 500
Operating mode • Discrete alarms Yes
• Operating options Touch • Message length (in characters) 1 x 80
• Touch screen Analog, resistive • Number of process values per 8
• Numeric/alphanumeric input Yes/No message
Processor/HW • Message buffer Ring buffer, 128 entries each
• Processor RISC 32 bits, 66 MHz Process images 250
Operating systems Windows CE Picture elements
Memory • Text objects 500 text elements
• Type Flash/RAM • Fields per screen 20
• Usable memory for project data 256 KB user memory/without • Variables/screen 20
additional memory for options • Graphics objects Bitmaps, icons, icon (filling the
screen)
Interfaces 1 x RS485 max. 0.1875 Mbit/s
• Dynamic objects Bar graphs
Supply voltage
Variables 250
• Supply voltage 24 V DC
• Permissible range +18 V to +30 V DC Security
• Rated current 0.24 A • Number of user groups 1
Software clock, without battery • Number of access rights 1
Clock/type
backup Fonts
Degree of protection • Keyboard fonts US English
• Front IP65, NEMA 4, NEMA 12; Languages
(when mounted)
• Online languages 5
• Rear IP20
• Project languages: D, GB, F, I, E, CHN "traditional",
Certification CE, FM Class I Div. 2, UL, CSA, CHN "simplified", DK, FIN, GR, J,
(some only as options) cULus, C-TICK KP/ROK, NL, N, PL, P, RUS, S,
CZ/SK, TR, H
Mechanical components/
dimensions • Character sets Tahoma, ideographic languages,
all freely scalable
• Front panel W x H (mm) 212 x 156
• Mounting cutout/depth W x H x D 198 x 142/45 mm depth of unit Transfer under ProTool
(mm) (upload/download)
• Weight 0.75 kg • Transfer of the configuration Serial
Ambient conditions
• Max. relative humidity (in %) 85%
• Mounting position Vertical
- Max. permissible angle of incli- +/- 35°
nation without external fan
• Temperature
- Operation (vertical installation) 0 to +50 °C
- Operation 0 to +40 °C
(max. angle of inclination)
- Transportation and storage -20 to +60 °C
140
156
• English 6AV6 691-1DB01-0AB0
• French 6AV6 691-1DB01-0AC0
• Italian 6AV6 691-1DB01-0AD0 42
• Spanish 6AV6 691-1DB01-0AE0
User Manual
WinCC flexible Micro
G_ST80_XX_00065
• German 6AV6 691-1AA01-0AA0
• English 6AV6 691-1AA01-0AB0
• French 6AV6 691-1AA01-0AC0 Panel cutout (W x H) in mm: 198 x 142
• Italian 6AV6 691-1AA01-0AD0
• Spanish 6AV6 691-1AA01-0AE0
SIMATIC HMI
Manual Collection
C 6AV6 691-1SA01-0AX0 ■ More information
Electronic documentation, For further information, visit our website at
on CD-ROM
5 languages (English, French,
German, Italian and Spanish);
contains: all currently available
user manuals, manuals and
communication manuals for
SIMATIC HMI
http://www.siemens.com/panels
Accessories for supplementary ordering
Cover foil 6AV6 574-1AD00-4AX0
Note
(pack of 10) Do you need a specific modification or option for the products
Protective cover 6AV6 574-1AE00-4AX0 described here? Then look up "customer-specific products",
where you will find information about additional sector-specific
(2 sets)
products that can be ordered as well as about options for
Service pack 6AV6 574-1AA00-4AX0 customer-specific modification and adaptation.
Consisting of:
• Installation sealing
• 2 sets of labeling strips (for OPs)
• 7 tensioning clamps
• Plug-in terminal block
(twin block)
PC/PPI cable Multimaster A 6ES7 901-3CB30-0XA0
(for download and test purposes)
For connecting the S7-200
to a serial PC/OP interface
and for configuration download
for Micro Panels
PROFIBUS connecting cable 6XV1 830-1CH30
830-1T
For connection of terminal unit,
pre-assembled with two sub D
connectors, 9-pin, 3 m
System interfaces See page 2/169
Connecting cables See page 2/180
■ Overview ■ Design
• 5.7” STN display, CCFL1) backlit, Bluemode (4 levels)
• Resistive analog Touch
• Compact design with small installation depth
2 • Rugged plastic housing
• The front is resistant to various oils, greases and standard
detergents
• Numeric system keyboard for decimal, binary and hexa-
decimal number formats
• On-screen alphanumeric keyboard
• Plug-in terminals for connecting a 24 V DC power supply
• RS 485 interface for connection of the MPI cable or the PPI
adaptor
■ Function
• Touch panel for operator control and monitoring of small • Input/output fields
machines and plants for displaying and changing process parameters
• Low-cost starter device in the touch panel class with graphical • Buttons
capability complete with all the basic functions required for for direct triggering of functions and actions. Up to 16 functions
simple tasks can be configured simultaneously on buttons
• Pixel graphics 5.7" STN touch screen (analog/resistive), Blue- • Graphics
mode (4 levels) can be used as icons instead of text to "label" function keys or
• Specifically for SIMATIC S7-200: buttons. They can also be used as background displays (wall-
Communication to the PLC is performed via the integrated paper).
interface over a point-to-point connection In the configuration tool, a library is available containing exten-
sive graphics and a wide variety of objects. All editors with an
• Connected to the PLC via MPI or PROFIBUS DP cable OLE interface can be used as graphics editors (such as Paint-
• The SIMATIC TP 177micro is the redesigned successor to the Shop, Designer or CorelDraw).
SIMATIC TP 070/TP 170micro touch panels • Vector graphics
Simple geometric basic forms (line, circle and rectangle) can
■ Benefits be created direct in the configuring tool
• Predefined texts
• Can even be used where installation space is restricted thanks
for labeling function keys, process images and process values
to vertical installation
in any character size
• Fast configuring and start-up
• Bars
• Service-friendly thanks to maintenance-free design and the for the graphical display of dynamic values
long service life of the backlighting
• Changing languages
• Graphics library is available complete with ready-to-use - 5 online languages, 32 configuration languages incl. Asian
display objects and Cyrillic character sets
• Can be used worldwide: • User administration (security)
- 32 languages can be configured (including Asiatic and - Authentication using password
Cyrillic character sets)
• Signaling system
- Up to 5 languages are selectable online
- Discrete alarms
- Freely definable message classes (e.g., status/fault
■ Application messages) for definition of acknowledgment response and
display of message events
TP 177micro Touch Panels can be used wherever small ma- - Message history
chines and systems are controlled and monitored locally – in • Help texts
production, process and building automation alike. They are for process images, messages and variables
used in all types of sectors and applications.
• Arithmetic functions
The TP 177micro has been designed specifically for use with the
• Limit value monitoring
SIMATIC S7-200. With fast response times, it is also ideal for jog
for reliable process control of inputs and outputs
mode.
• Indicator light
Compatibility with TP 070/TP 170micro for machine and plant status indication
• Same mounting cutout as the TP 070/TP 170micro. • Template concept
• TP 070 configurations cannot be transferred from TP Designer. Creation of picture templates (picture elements configured in
the template appear in every image)
• User-friendly maintenance and configuration thanks to:
- Backup and restoration of configuration, operating system
and firmware on a PC using ProSave
- Configuration download serially via RS485
- Individual contrast setting and calibration
- Clean screen
- No batteries are necessary
■ Dimension drawings
Dimensions in mm
212 44
6.2
140
156
■ Overview ■ Benefits
• Plugging and unplugging during operation without interrupting
the Emergency-Stop circuit (with “Plus“ junction box variants)
and without generating bus errors
• Fast, precise setup and positioning
2 • Reliable operation with tried and tested safety concept
(Safety Category 3 acc. to EN 954-1)
• Ergonomic and compact with low weight (approx. 1.3 kg)
• Rugged for industrial use
• Integral component of Totally Integrated Automation (TIA):
increases productivity, minimizes the engineering outlay,
reduces the lifecycle costs
• Graphics library available with pre-configured images
• The data in the message buffer are retained when the Mobile
Panel is unplugged, without batteries
• Worldwide implementation:
- 32 languages can be configured (incl. Asian and Cyrillic
fonts)
- Switching between up to 5 online languages is possible
• Mobile operator panel for direct operator control of the plant directly on the Mobile Panel
and machine from any point
• Reduction of service and commissioning costs through:
• Supports optimized monitoring of the workpiece or process - Backup/restore over a process interface or optionally over a
providing at the same time direct access and direct line of sight standard MMC (Multi Media Card).
to the operator panel - Configuration transfer with automatic transfer recognition
• Flexible implementation thanks to hot swapping over all device interfaces
• Pixel graphics, brilliant 5.7" color STN display with touch - Long service life of backlighting
screen (analog/resistive), 256 colors • Simple engineering supported with comprehensive documen-
• PROFIBUS or PROFINET variants tation on the SIMATIC HMI Manual Collection CD
• 14 user-configurable and user-inscribable function keys
(8 with LED) ■ Application
• Two three-stage enabling buttons; In every sector or application, when mobility is paramount in
Optional versions include: the operation and monitoring of machines and plants on site,
- STOP pushbutton SIMATIC Mobile Panels offer decisive advantages: Machine
- STOP pushbutton, handwheel, key-operated switch and operators or start-up engineers can move to the point from which
illuminated pushbutton they have the best view of the workpiece or process. Even in
• Communication is supported via a serial link, MPI/PROFIBUS large production plants, complex or enclosed machines, long
or PROFINET conveyor and production lines and in materials handling, mobile
• Connection point recognition operator panels support quick and accurate setting up and
positioning during start-up. During retrofitting, maintenance or
• Fast system availability after plugging into the junction box troubleshooting, they ensure shorter downtimes.
• Connected to the PLC and power supply via the junction box
and the connecting cable
■ Design
• Ergonomic and compact with different holding and gripping Sophisticated safety concept
points (suitable for right-handed and left-handed personnel)
The two enabling buttons (acc. to EN 60204-1) with three switch-
• Pixel graphics, brilliant 5.7" color STN display with 256 colors ing steps each ensure the protection of personnel and machines
and touch screen (analog/resistive) in critical situations. They are built into the rear handle.
• 14 user-configurable and user-inscribable function keys The STOP pushbutton (acc. to EN 60204-1) is hard-wired and
2
(8 with LED) positively latches when pressed. It can be looped into the
• The front is resistant to various oils, greases and standard emergency-stop circuit of a plant in which case it takes on the
detergents functionality of an emergency stop pushbutton, but is distinct
• Two three-stage enabling buttons with its gray color. This ensures that it cannot be mistaken for the
emergency stop equipment. This is especially important when
• Optional variants with the Mobile Panel is not connected to the machine. SIMATIC
- STOP pushbutton or Mobile Panels offer the option of making safety functions avail-
- STOP pushbutton, handwheel, key-operated switch and able on a mobile basis at any point of a machine or plant.
illuminated pushbutton
- The STOP pushbutton is secured specifically with a STOP pushbuttons and enabling buttons are implemented ac-
"protective collar". cording to safety regulations with two circuits and comply with
If the STOP pushbutton is looped into the emergency-stop the requirements of Safety Category 3 according to EN 954-1.
circuit, its function is equivalent to an emergency stop.
Innovative connection concept
• Extreme impact resistance thanks to the double-wall construc-
tion and rounded casing. The Mobile Panel is simply plugged into the connection box
(The Mobile Panel will withstand a fall from a height of 1.5 m wherever it is needed in the plant and is immediately ready for
without sustaining any damage.) use. The junction box can be installed anywhere, even outside
• Dust-proof and jet-proof casing with degree of protection IP65 the control cabinet. It ensures fault-free plugging and unplug-
on all sides ging during normal operation and, therefore, allows the operator-
control location to be easily and safely changed when several
• Integrated serial, MPI and PROFIBUS interface connection points are available in a plant or machine.
(up to 12 Mbit/s) for the Mobile Panel 177 DP The location of a Mobile Panel can be clearly identified by set-
Or ting an ID number on the junction box. This identifier permits the
user to configure Mobile Panels in such a way that, for example,
• Integral Ethernet (PROFINET) interface (up to 100 Mbit/s) the user interface changes according to the connection point.
with the Mobile Panel 177 PN The Mobile Panel 177 establishes the connection to the control-
• Slot for a standard Multi Media Card (MMC) for backup and lers after being plugged into the junction boxes and following a
restoration or for storing recipes short running-up period. An optional rechargeable battery pack
• Connection to the PLC via the rugged and reliable junction can be used to speed up the Mobile Panel connection process
boxes with IP65 degree of protection: (following a brief period of disconnection from the junction box)
- “Basic“ junction box: Enables the STOP pushbutton to be still further.
integrated into the safety circuit Any existing Mobile Panel 170 junction boxes can be used in
- "Plus" junction box: Enables the STOP pushbutton to be conjunction with the Mobile Panel 177 because they are fully
integrated into the safety circuit. compatible. The new function of connection-point detection can
The emergency stop circuit is not interrupted even if the only be used in conjunction with a Mobile Panel 177 with a DP or
Mobile Panel is unplugged. If the Mobile Panel is discon- PN junction box. A Mobile Panel 177 DP (PROFIBUS) cannot be
nected during operation, the emergency stop circuit in the connected to a PN (PROFINET) junction box and vice versa and
junction box Plus is automatically closed which prevents is mechanically blocked.
triggering of the emergency stop circuit.
• Fast system availability after plugging into the junction boxes Configuration options with emergency stop wiring
- An optional rechargeable battery pack can be used to speed Panels with a STOP pushbutton can be integrated into the emer-
up the Mobile Panel connection process (following a brief gency stop circuit of a machine or plant via the junction box.
period of disconnection from the junction box) still further. When the STOP pushbutton on the Mobile Panel is pressed, the
• Detection of the connection point can be used to perform emergency stop function is activated. The STOP pushbutton on
machine-specific HMI authorizations or actions depending on the Mobile Panel supplements but does not replace the emer-
the selected connection point gency stop equipment installed on the machine according to
EN 418. When the Mobile Panel is unplugged, "Plus" versions of
the junction box automatically close the emergency stop circuit,
thereby ensuring safe and fault-free changeover (swapping).
■ Design (continued)
Connection at one point of the machine
When the “Basic“ junction box variant is used, unplugging the This configuration is, therefore, best suited for applications
Mobile Panel interrupts the emergency stop circuit and, there- in which the Mobile Panel is connected to a fixed point on the
2 fore, triggers the emergency stop function. machine.
Wiring into the emergency stop circuit - Mobile Panel connected - emergency stop circuit closed
with connection box Basic - Mobile Panel disconnected - emergency stop circuit open
->Emergency stop is triggered
MPI/PROFIBUS DP
Connection box
Basic
Emergency
stop circuit
G_ST80_XX_00068
Flexible connection at various points
on a machine or in a plant
If a Mobile Panel with a STOP pushbutton is used in combination equipment is looped into the emergency stop circuit and when
with a “Plus“ junction box, a configuration is possible in which the STOP pushbutton is pressed, the circuit will be interrupted
the Mobile Panel can be used flexibly and is also looped into the and the emergency stop function triggered. If the Mobile Panel
emergency stop circuit. The emergency stop circuit remains is unplugged during operation, the emergency stop circuit is
closed regardless of whether a Mobile Panel is plugged into a automatically closed in the “Plus“ junction box variant.
junction box or not. When the Mobile Panel is plugged in, the
Automatic closing of emergency stop circuit - Mobile Panel connected - emergency stop circuit closed
by connection box Plus - Mobile Panel disconnected - emergency stop circuit open
MPI/PROFIBUS DP
■ Function
• Input/output fields • Mathematical functions
for displaying and changing process values • Limit value monitoring
• Function keys for reliable process control of inputs and outputs
for direct triggering of functions and actions. Up to 16 functions
can be configured simultaneously on function keys. The func-
tion keys can also be used as PROFIBUS DP input peripherals
• Indicator light
for machine and plant status indication 2
or directly as PROFINET IO. • Task planner
The function keys can also be reconfigured as system keys. for cyclic function processing
A function that is frequently used such as "Acknowledge mes- • Dynamic positioning of objects and dynamic showing/hiding of
sage" can therefore be assigned to a function key. objects
• Additional command elements • Permanent window and template concept
such as hand wheels, key-operated switches and illuminated - generation of screen templates
pushbutton units can be connected to a variable or as direct • Simple maintenance and configuration through
control through PROFIBUS DP input I/O (DP direct keys) or - Backup and restoring of project, operating system, recipe
PROFINET IO (direct keys). records and firmware on the optional standard MMC
• Buttons (Multi Media Card)
for direct triggering of functions and actions. Up to 16 functions - Backup and restoring the configuration, operating system,
can be configured simultaneously on buttons. data records and firmware on a PC using ProSave
• Graphics - Project transfer over MPI/PROFIBUS DP/serial or PROFINET
can be used as symbols instead of text to label function keys - Automatic transfer identification
or buttons. They can also be used as background displays - Individual contrast settings
(wallpaper). - Project simulation directly on the configuration computer
The configuration software provides a comprehensive library of • WinCC flexible options
graphics and various objects. All editors with an OLE interface - Sm@rtService for remote operation and monitoring of
can be used as graphics editor (such as PaintShop, Designer SIMATIC HMI systems over TCP/IP networks
or CorelDraw). - Sm@rtAccess for communication between HMI systems over
• Vector graphics; TCP/IP networks. Remote access to recipe data sets, pass-
simple geometric forms (e.g. lines, circles and rectangles) can words and information specific to the HMI system and a great
be created directly in the configuration software deal more
• Text fields Configuration
for labeling function keys, process diagrams and process
values in any font size Configuration is carried out using the
SIMATIC WinCC flexible Compact, Standard or Advanced con-
• Curve displays and bars figuration software (see HMI software/engineering software
are used for graphical display of dynamic values SIMATIC WinCC flexible). SIMATIC WinCC flexible represents a
• Display selection from the PLC consistent further development of the well-proven ProTool family.
supports operator prompting from the PLC Projects generated using ProTool can easily migrate to WinCC.
• Language selection; If WinCC flexible can be started directly from SIMATIC Manager,
5 online languages, 32 configuration languages incl. Asiatic the data can be accessed directly in STEP 7 when the panel is
and Cyrillic character sets configured. Duplicated data input and data management is
- Language-dependent texts and graphics therefore avoided.
• User administration (security) Projects created using ProTool for the Mobile Panel 170 can be
- User-oriented access protection according to requirements easily reused in WinCC flexible.
of specific sectors
- Authentication with user name and password
- Privileges specific to user groups
• Message system
- Bit messages and analog messages (limit value messages)
as well as the Alarm_S message frame procedure for
SIMATIC S7 and SIMOTION
- Freely-definable message classes (e.g. status/fault
messages) for definition of acknowledgment response and
display of message events
• Message buffer
- Non-volatile, maintenance-free and battery-free message
buffer. Messages are retained even when the Mobile Panel is
unplugged.
• Recipe management
- With additional data storage (on optional MMC)
- Online/offline processing at the panel
- Storage of recipe data in standard Windows format (CSV)
- External processing using standard tools such as Excel and
Access is possible
• Help texts
for process diagrams, messages and variables
■ Integration
Communication with the PLC is possible with the Mobile Panel • Non-Siemens controllers
177 DP over PROFIBUS DP at up to 12 Mbit/s, over the MPI or - Allen Bradley
serial interfaces. The interfaces are integrated. Various drivers – - Mitsubishi
also for non-Siemens PLCs – are included in the standard scope - Modicon Modbus
2 of supply. - GE-Fanuc
- LG GLOFA GM
Communication with the PLC is possible with the Mobile Panel - Omron
177 PN over PROFINET at up to 100 Mbit/s. The interface is in-
tegrated. Drivers are included in the standard scope of supply. • SINUMERIK
(optionally with "SINUMERIK HMI copy license
Using the DP junction boxes, the Mobile Panel 177 DP can be WinCC flexible CE"; the "SINUMERIK HMI engineering pack-
connected to: age WinCC flexible" is additionally necessary for configuration;
• SIMATIC S7-200/-300/-400 for further information, see Catalog NC 60)
• SIMATIC WinAC Software/Slot PLC Using the PN junction boxes, Mobile Panel 177 PN can be
connected to:
• SIMOTION
• SIMATIC S7-200/-300/-400
• SIMATIC S5
• WinAC Software
• SIMATIC 505 • SIMOTION
Note:
For further information see "System interfaces".
■ Technical specifications
Type SIMATIC Mobile Panel 177 DP SIMATIC Mobile Panel 177 DP SIMATIC Mobile Panel 177 DP
Design variant With integrated enabling button With integrated enabling button With integrated enabling button,
and STOP pushbutton STOP pushbutton, handwheel, key-
operated switch and illuminated
pushbutton
Display STN liquid crystal display (LCD) STN liquid crystal display (LCD) STN liquid crystal display (LCD)
• Size 5.7'' 5.7'' 5.7''
• Resolution (W x H in pixels) 320 x 240 320 x 240 320 x 240
• Colors 256 colors 256 colors 256 colors
• MTBF of background lighting approx. 50,000 hours approx. 50,000 hours approx. 50,000 hours
(at 25 °C)
Control elements
• Operating options Touch and Key Touch and Key Touch and Key
• Programmable, inscribable func- 14 (8 with green LED) 14 (8 with green LED) 14 (8 with green LED)
tion keys
• Numeric/alphanumeric input Yes/Yes 1) Yes/Yes 1) Yes/Yes 1)
• STOP pushbutton No 2-channel, positive latching, can be 2-channel, positive latching, can be
wired into emergency-stop circuit wired into emergency-stop circuit
• Enable switch 2-channel, 3-stage 2-channel, 3-stage 2-channel, 3-stage
• Handwheel No No Yes
• Key-operated switch No No Yes, with 3 switch positions, key
can be removed in any one position
• Illuminated pushbutton No No Yes
Expansions for operator-process
communication
• Direct keys/LEDs (buttons, func- Via DP direct keys Via DP direct keys Via DP direct keys
tion keys and control elements
such as handwheel, key-operated
switch and illuminated pushbutton
unit) as I/O peripherals
Operating system Windows CE Windows CE Windows CE
Memory
• Type Flash/RAM Flash/RAM Flash/RAM
• Available memory for user data 2048 KB 2048 KB 2048 KB
Interfaces 1 x RS422, 1 x RS485 1 x RS422, 1 x RS485 1 x RS422, 1 x RS485
• MMC slot (Multi Media Card) 1 1 1
Connection to controller S5, S7-200, S7-300/400, 505, S5, S7-200, S7-300/400, 505, S5, S7-200, S7-300/400, 505,
WinAC Soft/Slot PLC WinAC Soft/Slot PLC WinAC Soft/Slot PLC
(V 3.0 and higher), SIMOTION, (V 3.0 and higher), SIMOTION, (V 3.0 and higher), SIMOTION,
Allen Bradley (DF1), Modicon Allen Bradley (DF1), Modicon Allen Bradley (DF1), Modicon
(Modbus), LG GLOFA GM, (Modbus), LG GLOFA GM, (Modbus), LG GLOFA GM, other
other non-Siemens PLCs other non-Siemens PLCs non-Siemens PLCs
Clock Software clock, synchronized, Software clock, synchronized, Software clock, synchronized,
not battery-backed not battery-backed not battery-backed
Type SIMATIC Mobile Panel 177 PN SIMATIC Mobile Panel 177 PN SIMATIC Mobile Panel 177 PN
Design variant With integrated enabling button With integrated enabling button With integrated enabling button,
and STOP pushbutton STOP pushbutton, handwheel, key-
operated switch and illuminated
pushbutton
Display STN liquid crystal display (LCD) STN liquid crystal display (LCD) STN liquid crystal display (LCD)
• Size 5.7'' 5.7'' 5.7''
• Resolution (W x H in pixels) 320 x 240 320 x 240 320 x 240
• Colors 256 colors 256 colors 256 colors
• MTBF of background lighting approx. 50,000 hours approx. 50,000 hours approx. 50,000 hours
(at 25 °C)
Control elements
• Operating options Touch and Key Touch and Key Touch and Key
• Programmable, inscribable 14 (8 with green LED) 14 (8 with green LED) 14 (8 with green LED)
function keys
• Numeric/alphanumeric input Yes/Yes 1) Yes/Yes 1) Yes/Yes 1)
• STOP pushbutton No 2-channel, positive latching, can be 2-channel, positive latching, can be
wired into emergency-stop circuit wired into emergency-stop circuit
• Enable switch 2-channel, 3-stage 2-channel, 3-stage 2-channel, 3-stage
• Handwheel No No Yes
• Key-operated switch No No Yes, with 3 switch positions, key
can be removed in any one position
• Illuminated pushbutton No No Yes
Expansions for operator-process
communication
• PROFINET I/O direct keys/LEDs Via PROFINET 10 1) Via PROFINET 10 1) Via PROFINET 10 1)
(buttons, function keys and control
elements such as handwheel,
mode selector and illuminated
pushbutton unit) as I/O peripherals
Operating system Windows CE Windows CE Windows CE
Memory
• Type Flash/RAM Flash/RAM Flash/RAM
• Available memory for user data 2048 KB 2048 KB 2048 KB
Interfaces 1 x Ethernet with 10/100 Mbit/s 1 x Ethernet with 10/100 Mbit/s 1 x Ethernet with 10/100 Mbit/s
1 x RS 485 1 x RS 485 1 x RS 485
• MMC slot (Multi Media Card) 1 1 1
Connection to controller S7-200, S7-300/400, S7-200, S7-300/400, S7-200, S7-300/400,
WinAC software, SIMOTION WinAC software, SIMOTION WinAC software, SIMOTION
Clock Software clock, synchronized, Software clock, synchronized, n Software clock, synchronized, n
not battery-backed ot battery-backed ot battery-backed
1) PROFINET I/O direct key functionality only with WinCC flexible 2005 SP1
A) Subject to export regulations AL: N and ECCN: EAR99H 1) Delivery period approx. 6 weeks
C) Subject to export regulations AL: N and ECCN: EAR99S 2) Does not apply to Mobile Panel 170
■ Dimension drawings
Dimensions in mm Dimensions in mm
123.9
2 o
7.8
24.6
18
121.7 8o
225.2
245
92.3
G_ST80_XX_00046
G_ST80_XX_00047
100.7 8o
2
61.3
SIMATIC Mobile Panel front and rear views Wall mount for SIMATIC Mobile Panel
■ More information
Dimensions in mm
For further information, visit our website at
140
62.7
10
43
http://www.siemens.com/mobile-panels
160 Note
150 Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about additional sector-specific prod-
ucts that can be ordered as well as about options for customer-
specific modification and adaptation.
110
120
142 ± 2
G_ST80_XX_00045
■ Overview ■ Design
The TD17 Text Display is based on OP7/OP17 technology.
• LED-backlit LCD:
- 4-line, 20 characters/line; character height 11 mm or
- 8-line, 40 characters/line; character height 6 mm.
• 7 system keys 2
• Metal-reinforced plastic housing with membrane front
• The front is resistant to various oils, greases and standard
detergents
• Small mounting depth
• Electronic fuse
■ Function
Message functions
• Integration of up to 8 process values per message
• Status message and system message buffers
• Scrolling through messages
• Text display for message display and storage
• Definition of message priorities
• Can be used both direct at the machine and in a control room
• Date and time in messages
• LED-backlit LCD:
- 4 lines, 20 characters/line; character height 11 mm or • Upper-case and lower-case text can be mixed
- 8 lines, 40 characters/line; character height 6 mm. Further functions
• 7 system keys • Loadable firmware
• Alternatively, the TP 177 Touch Panel can also be used as a • Contrast adjustment
text-only display panel.
• Convenient native drivers for wide range of non-Siemens PLCs
• Backup/restore of firmware and user data (ProSave)
■ Benefits • PLC tasks for activating PLC-controlled actions
• Clearly contrasting display, easier to read
• Language selection from 3 online languages
• Large keys for enhanced operating reliability
• Fast variable updating Configuration
• Easy handling and configuration Configuration is performed using the software SIMATIC Pro-
Tool/Lite, SIMATIC ProTool or SIMATIC ProTool/Pro Configuration
• Maintenance-free thanks to electronic fuse
(see Configuration software or Visualization software)
■ Application ■ Integration
The TD17 Text Displays can be used in all applications in which
The TD17 can be connected to:
monitoring of machines and installations is required on site –
whether in production automation, process automation or build- • SIMATIC S7-200/-300/-400
ing service automation. They are in use in an extensive range of • SIMATIC WinAC Software/Slot PLC
sectors and applications.
• SIMATIC S5
The TD17 is simply for display purposes and does not support • SIMATIC 505
intervention in the process.
• SINUMERIK
• Non-Siemens PLCs, including
- Allen Bradley
- Mitsubishi
- Telemecanique
- Modicon
- Omron
- GE Fanuc
Note:
For further information, see "System interfaces".
■ Technical specifications
SIMATIC TD17 SIMATIC TD17
Display Ambient conditions
• Display type LC-Display • Max. relative humidity (in %) 95%
2 • Number of lines (max.) 8 • Mounting position
- Max. permissible angle of incli-
Vertical
+/- 90°
• Characters per line (max.) 40
nation withou t external fan
• Character height (mm) 6 or11
• Temperature
• Colors Monochrome - Operation (vertical installation) 0 to +50 °C
• MTBF of background lighting approx. 200,000 hours - Operation (max. angle of inclina- 0 to +35 °C
(at 25 °C) tion)
Operating mode - Transportation and storage -25 to +70 °C
• Operating options Keys Configuring
• Membrane keyboard Yes • Configuration tool ProTool
• System keys 7 Functionality (under ProTool)
Processor/HW • Password protection 10
(number of levels)
• Processor X86
• Help system Yes
Operating systems RMOS
Protocols
Memory
• Interface to PLC S5, S7-200, S7-300/400, 505,
• Type Flash/RAM (may only be an option) SINUMERIK, Mitsubishi (FX),
• Usable memory for project data 128 KB user memory/without Telemecanique (ADJUST),
additional memory for options Modicon (Modbus) and other
non-Siemens drivers
Interfaces 1 x TTY, 1 x RS232, 1 x RS422, 1 x
RS485 max. 12 Mbit/s Signaling system
98
89
Multi-language (English, French,
German, Italian and Spanish)
Communication manual
231 51 1)
Instructions for connection of 4
TD/OP to the controller 240
G_ST80_XX_00062
• French 6AV3 991-1BC05-1AC0
• Italian 6AV3 991-1BC05-1AD0
• Spanish 6AV3 991-1BC05-1AE0 1) Depth includes connectors and cable connectors
Panel cutout (W x H) in mm: 231 x 89
SIMATIC HMI C 6AV6 691-1SA01-0AX0
Manual Collection
Electronic documentation,
on CD-ROM
5 languages (English, French,
■ More information
German, Italian and Spanish); For further information, visit our website at
Comprising: all currently available
user manuals, product manuals
and communication manuals
for SIMATIC HMI
Accessories for supplementary ordering
Service package 6AV3 678-1CC10
for TD17, OP7 and OP17 1) http://www.siemens.com/panels
comprising:
• 1 x TD17 gasket
Note
• 1 x OP7 gasket Do you need a specific modification or option for the products
• 1 x OP17 gasket described here? Then look up "Customized products",
• 5 x clamping blocks where you will find information about additional sector-specific
products that can be ordered as well as about options for
• 2-pin plug-in terminal strip customer-specific modification and adaptation.
Backup battery W79084-E1001-B2
Lithium battery, 3.6 V DC;
1.7 Ah for TD17, OP17, OP25,
OP27, OP 270, OP35, OP37,
TP27, TP 270, TP37, MP 270,
MP 270B, MP 370
RS 485 bus connector 6GK1 500-0EA02
with axial cable outlet (180°)
System interfaces See page 2/160
Connecting cables See page 2/180
■ Overview ■ Function
Operator functions
• Alphanumeric setpoint input using system keys
• Softkeys (function of the keys can be configured context-
2 sensitive)
Message functions
• Display of process values
• Management and processing of status messages
• Date and time in messages
• Definition of message priorities
Further functions
• Limit monitoring of inputs
• STATUS VAR/CONTROL VAR in combination with SIMATIC S7
• Password protection
• Language selection from 3 online languages
• Contrast adjustment
• Operator Panel for controlling and monitoring machines and • Linear conversion
systems.
• Variable limit values
• Specifically for SIMATIC S7
• Can also be used as a handheld device Configuration
• LED-backlit LCD: 2 lines, 20 characters/line; character height Configuration is performed using the software SIMATIC Pro-
5 mm Tool/Lite, SIMATIC ProTool or SIMATIC ProTool/Pro Configuration
• 18 system keys, 5 of which are user-configurable function keys (see Configuration Software or Visualization software)
• The OP3 Operator Panel is soon to be replaced by its innova-
tive successor, the SIMATIC OP 73. ■ Integration
Fast and easy coupling to SIMATIC S7-200, S7-300, S7-400
■ Benefits PLCs (PPI or MPI) is possible over the integral interface.
• Easy handling and configuration An additional master (e.g. PG or OP) is permissible in the PPI
• Small and compact network.
• Extensive functionality, e.g.:
- Linear conversion Note
- Variable limit values For further information, see "System interfaces".
- PG function STATUS/CONTROL of variables
■ Application
The OP3 Operator Panels can be used in all small-scale appli-
cations in which operator control and monitoring of machines
and installations is required on site – whether in production
automation, process automation or building service automation.
They are in use in an extensive range of sectors and applica-
tions.
■ Design
• LED-backlit LCD, 2-line, 20 characters/line; character height
5 mm
• 18 system keys, of which 5 are freely configurable function
keys
• Plastic housing with membrane front
• The front is resistant to various oils, greases and standard
detergents
• Small mounting depth
■ Technical specifications
SIMATIC OP3 SIMATIC OP3
Display Ambient conditions
• Display type LC display • Max. relative humidity (in %) 85%
• Number of lines (max.) 2 • Mounting position
- Max. permissible angle of
Vertical
+/- 180°
2
• Characters per line (max.) 20
inclination without external fan
• Character height (mm) 5
• Temperature
• Colors Monochrome - Operation (vertical installation) 0 to +60 °C
• MTBF of background lighting approx. 200,000 hours - Operation 0 to +60 °C
(at 25 °C) (max. angle of inclination)
Operating mode - Transportation and storage -20 to +60 °C
• Operating options Keys Configuring
• Function keys, programmable 5 function keys • Configuration tool ProTool
• Membrane keyboard Yes Functionality (under ProTool)
• System keys 18 • Password protection 10
(number of levels)
• Numeric/alphanumeric input Yes/No
• Help system No
Processor/HW
• PG functions (STATUS/CONTROL) with SIMATIC S5/S7
• Processor X86
Protocols
Operating system RMOS
• Interface to PLC S7-200, S7-300/400
Memory (may only be an option)
• Type Flash/RAM Signaling system
• Usable memory for project data 128 KB user memory/without • Status messages 499
additional memory for options
• System messages Yes
Interfaces 1 x RS232, 1 x RS485
max. 1.5 Mbit/s • Message length 2 x 20
(lines x characters)
Supply voltage
• Number of process values 8
• Supply voltage 24 V DC in messages
• Permissible range +18 V to +30 V DC • Process images 40
• Rated current 0.07 A • Fields per screen 20
• Output 2.4 W Languages
Clock Software clock, without battery • Online languages 3
backup
• Project languages G/E/F/I/S
Degree of protection
Transfer of the configuration MPI/PROFIBUS DP (if available),
• Front IP65 serial
• Rear IP20
Certification CE, GL, BV, DNV, LRS, PRS,
(some only as options) FM Class I Div. 2, UL, CSA,
EX zone 22
Mechanical components/
dimensions
• Front panel W x H (mm) 148 x 76
• Mounting cutout/depth W x H x D 138 x 68/25 mm depth of unit
(mm)
• Weight 0.25 kg
68
76
• Cable (5 m) for 24 V DC power
supply
138 20 4
Configuring
148 27
with SIMATIC ProTool/Lite, See Section 4
ProTool or ProTool/Pro
Documentation (to be ordered separately)
G_ST80_XX_00057
OP3 Manual
• German 6AV3 591-1AD00-1AA0
• English 6AV3 591-1AD00-1AB0
• French 6AV3 591-1AD00-1AC0 Panel coutout (W x H) in mm: 138 x 68
■ Overview ■ Function
Operator functions
• Alphanumeric/numerical setpoint input via system keys
• Softkeys (function of keys can be configured depending on
screen)
• Slide-in labels for all function keys
2
Signaling functions
• Process value display
• Management and processing of status and fault messages
• Messages with date and time stamp
• Definition of message priorities
• Differentiation between first-up and last-up messages
• Help texts for alarms, screens, etc.
Additional functions
• Limit value check for entries
• STATE VAR/CONTROL VAR in conjunction with SIMATIC S5
• Compact, multi-functional operator panel for operator control and S7
and monitoring of machines and plants • Password protection
• LED-backlit LCD: 4-line, 20 characters/line; character height • Language selection with 3 online languages
8 mm
• 17 languages can be configured incl. system messages
• 22 system keys, 8 freely-configurable and freely-inscribable (incl. Cyrillic character sets)
function keys (4 with LEDs)
• Contrast settings
• PLC requests to trigger PLC-controlled actions
■ Benefits • Recipe management
• Clearly contrasting display, easier to read
• DP direct keys for fast and deterministic operator actions
• Large keys for enhanced operating reliability
• Linear conversion
• Fast variable updating
• Native drivers for non-Siemens PLCs
• Extensive functionality for efficient HMI – from receipe manage-
• PROFIBUS DP up to 12 Mbit/s
ment through linear conversion as far as the backing up and
restoring of firmware and user data • Variable limit values
• Easy handling and configuration • Printer port via integrated interface
• Maintenance-free thanks to electronic fuse Service concept
• Backup/restoration of configuration, firmware and recipe data
■ Application sets
• Loadable firmware
The OP7 Operator Panels can be used in all applications in
which operator control and monitoring of machines and installa- Configuring
tions is required on site – whether in production automation,
process automation or building service automation. They are in Configuration is performed using the SIMATIC ProTool/Lite,
use in an extensive range of sectors and applications. SIMATIC ProTool or SIMATIC ProTool/Pro Configuration software
(see Configuration or Visualization software)
■ Design ■ Integration
• LED-backlit LCD, 4-line, 20 characters/line; character height
8 mm The OP7 can be connected to:
• 22 system keys, 8 freely-configurable and freely-inscribable • SIMATIC S7-200/-300/-400
function keys (4 with LEDs) • SIMATIC WinAC Software/Slot PLC
• Plastic housing with membrane front • SIMATIC S5
• The front is resistant to various oils, greases and standard • SIMATIC 505
detergents
• SINUMERIK
• Small mounting depth
• Non-Siemens PLCs, e.g.
• Electronic fuse - Allen Bradley
• Interfaces: - Mitsubishi
- OP7/PP: - Telemecanique
RS 232/TTY, RS 485/422 - Modicon
- OP7/DP: - Omron
RS 232, RS 485/422, - GE Fanuc
PPI/MPI/PROFIBUS DP up to 1.5 Mbit/s
- OP7/DP-12: Note:
RS 232/TTY, RS 485/422, For further information, see "System interfaces".
PPI/MPI/PROFIBUS DP up to 12 Mbit/s
■ Technical specifications
SIMATIC OP7/PP SIMATIC OP7/DP SIMATIC OP7/DP-12
Display
• Display type LC display LC display LC display
2 • Number of lines (max.) 4 4 4
• Characters per line (max.) 20 20 20
• Character height (mm) 8 8 8
• Colors Black/white Black/white Black/white
• MTBF of background lighting approx. 100,000 hours approx. 100,000 hours approx. 100,000 hours
(at 25 °C)
Operating mode
• Control elements Membrane keyboard Membrane keyboard Membrane keyboard
• Operating options Keys Keys Keys
• Function keys, programmable 8 function keys, 4 with LEDs 8 function keys, 4 with LEDs 8 function keys, 4 with LEDs
• Membrane keyboard Yes Yes Yes
• System keys 22 22 22
• Numeric/alphanumeric input Yes/No Yes/No Yes/No
Processor/HW
• Processor X86 X86 X86
Operating systems RMOS RMOS RMOS
Memory
• Type Flash/RAM Flash/RAM Flash/RAM
• Usable memory for project data 128 KB user memory/without 128 KB user memory/without 128 KB user memory/without
additional memory for options additional memory for options additional memory for options
Interfaces 1 x TTY, 1 x RS232, 1 x TTY,
1 x RS232, 1 x RS422, 1 x RS232,
1 x RS485 max. 1.5 Mbit/s 1 x RS485 max. 1.5 Mbit/s 1 x RS422,
1 x RS485 max. 12 Mbit/s
Supply voltage
• Supply voltage 24 V DC 24 V DC 24 V DC
• Permissible range +18 V to +30 V DC +18 V to +30 V DC +18 V to +30 V DC
• Rated current 0.19 A 0.19 A 0.19 A
Clock Software clock, without battery Software clock, without battery Software clock, without battery
backup backup backup
Degree of protection
• Front IP65 (when mounted) NEMA 4 IP65 (when mounted) NEMA 4 IP65 (when mounted) NEMA 4
• Rear IP 20 IP 20 IP 20
Certification CE, GL, BV, DNV, LRS, PRS, CE, GL, BV, DNV, LRS, PRS, CE, GL, BV, DNV, LRS, PRS,
(some only as options) FM Class I Div. 2, UL, CSA, cULus, FM Class I Div. 2, UL, CSA, cULus, FM Class I Div. 2, UL, CSA, cULus,
EX zone 2/22 EX zone 2/22 EX zone 2/22
Mechanical components/
dimensions
• Front panel W x H (mm) 144 x 180 144 x 180 144 x 180
• Mounting cutout/depth W x H x D 135 x 171/38.5 mm depth of unit 135 x 171/38.5 mm depth of unit 135 x 171/38.5 mm depth of unit
(mm)
• Weight 0.43 kg 0.43 kg 0.43 kg
Ambient conditions
• Max. relative humidity (in %) 95% 95% 95%
• Mounting position Vertical Vertical Vertical
- Max. permissible angle of +/- 90° +/- 90° +/- 90°
nclination without external fan
• Temperature
- Operation (vertical installation) 0 to +50 °C 0 to +50 °C 0 to +50 °C
- Operation 0 to +35 °C 0 to +35 °C 0 to +35 °C
(max. angle of inclination)
- Transportation and storage -25 to +70 °C -25 to +70 °C -25 to +70 °C
2
42,5 http://www.siemens.com/panels
144
39
30
Note
116,5 Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about additional sector-specific
180
171
29
135
G_ST80_XX_00058
■ Overview ■ Function
Operator functions
• Alphanumeric/numerical setpoint input via system keys
• Softkeys (function of keys can be configured depending on
2 screen)
• Slide-in labels for all function keys
• Some function keys with LED
Signaling functions
• Process value display
• Management and processing of status and fault messages
• Messages with date and time stamp
• Definition of message priorities
• Differentiation between first-up and last-up messages
• Help texts for alarms, screens, etc.
• Mixed use of uppercase and lowercase
Additional functions
• High-performance operator panel for easy operator control • Limit value check for entries
and monitoring of machines and plants • STATE VAR/CONTROL VAR in conjunction with SIMATIC S5
• LED-backlit LCD: and S7
- 4-line, 20 characters/line; character height 11 mm or • Password protection
- 8-line, 40 characters/line; character height 6 mm • Language selection with 3 online languages
• 22 system keys, 24 freely-configurable and freely-inscribable • 17 languages can be configured incl. system messages
function keys (16 with LEDs) (incl. Cyrillic character sets)
• Contrast settings
■ Benefits • PLC requests to trigger PLC-controlled actions
• Recipe management
• Contrast-rich display
• DP direct keys for fast and deterministic operator actions
• Large keys for improved operational reliability
• Linear conversion
• Fast variable update
• Native drivers for non-Siemens PLCs
• Extensive functionality for efficient operator control and moni-
toring – from recipe management through linear conversion all • PROFIBUS DP up to 12 Mbit/s
the way to backup/restoration of firmware and user data • Variable limit values
• Easy to handle and configure • Internal real-time clock
• Electronic fuse protection • 48 clock prompts
• Printer port
■ Application Service concept
The OP17 Operator Panels can be used in all applications in • Backup/restoration of configuration, firmware and recipe data
which operator control and monitoring of machines and installa- sets
tions is required locally – whether in production automation, pro- • Loadable firmware
cess automation or building service automation. They are in use
in an extensive range of sectors and applications. Configuring
Configuration is performed using the SIMATIC ProTool/Lite,
■ Design SIMATIC ProTool or SIMATIC ProTool/Pro Configuration software
(see Configuration or Visualization software)
• LED-backlit LCD;
- 4 lines, 20 characters/line; character height 11 mm or
- 8 lines, 40 characters/line; character height 6 mm ■ Integration
• 22 system keys, 24 freely-configurable and freely-inscribable The OP17 can be connected to:
function keys (16 with LEDs)
• SIMATIC S7-200/-300/-400
• Plastic enclosure with membrane front
• SIMATIC WinAC Software/Slot PLC
• The front is resistant to various oils, greases and standard
detergents • SIMATIC S5
• Low mounting depth • SIMATIC 505
• Electronic fuse protection • SINUMERIK
• Optional battery can be used (required for message buffer and • Non-Siemens PLCs, e.g.
clock) - Allen Bradley
• Interfaces: - Mitsubishi
- OP17/PP: - Telemecanique
RS 232/TTY, RS 485/422 - Modicon
- OP17/DP: - Omron
RS 232, RS 485/422, - GE Fanuc
PPI/MPI/PROFIBUS DP up to 1.5 Mbit/s Note:
- OP17/DP-12: For further information, see "System interfaces".
RS 232/TTY, RS 485/422,
PPI/MPI/PROFIBUS DP up to 12 Mbit/s
■ Technical specifications
SIMATIC OP17/PP SIMATIC OP17/DP SIMATIC OP17/DP-12
Display
• Display type LC display LC display LC display
• Number of lines (max.)
• Characters per line (max.)
8
40
8
40
8
40
2
• Character height (mm) 6 or 11 6 or 11 6 or 11
• Colors Black/white Black/white Black/white
• MTBF of background lighting approx. 200,000 hours approx. 200,000 hours approx. 200,000 hours
(at 25 °C)
Operating mode
• Control elements Membrane keyboard Membrane keyboard Membrane keyboard
• Operating options Keys Keys Keys
• Function keys, programmable 24 function keys, 16 with LEDs 24 function keys, 16 with LEDs 24 function keys, 16 with LEDs
• Membrane keyboard Yes Yes Yes
• System keys 22 22 22
• Numeric/alphanumeric input Yes/No Yes/No Yes/No
Processor/HW X86 X86 X86
Operating systems RMOS RMOS RMOS
Memory
• Type Flash/RAM Flash/RAM Flash/RAM
• Usable memory for project data 256 KB user memory/without 256 KB user memory/without 256 KB user memory/without
additional memory for options additional memory for options additional memory for options
Interfaces 1 x TTY, 2 x RS232, 1 x RS422, 2 x RS232, 1 x RS422, 1 x RS485 1 x TTY, 2 x RS232, 1 x RS422,
1 x RS485 max. 1.5 Mbit/s max. 1.5 Mbit/s 1x RS485 max. 12 Mbit/s
Supply voltage
• Supply voltage 24 V DC 24 V DC 24 V DC
• Permissible range +18 V to +30 V DC +18 V to +30 V DC +18 V to +30 V DC
• Rated current 0.34 A 0.34 A 0.34 A
• Output 10 W 10 W 10 W
• Backup battery Optional 3.6 V Optional 3.6 V Optional 3.6 V
Clock Hardware clock battery-backed Hardware clock battery-backed Hardware clock battery-backed
and synchronized and synchronized and synchronized
Degree of protection
• Front IP65 (when mounted) - IP65 (when mounted) - IP65 (when mounted) -
• Rear IP 20 IP 20 IP 20
Certification CE, PRS, FM Class I Div. 2, UL, CE, PRS, FM Class I Div. 2, UL, CE, PRS, FM Class I Div. 2, UL,
(some only as options) EX zone 22 EX zone 22 EX zone 22
Mechanical components/
dimensions
• Front panel W x H (mm) 240 x 204 240 x 204 240 x 204
• Mounting cutout/depth W x H x D 231 x 195/50 mm depth of unit 231 x 195/50 mm depth of unit 231 x 195/50 mm depth of unit
(mm)
• Weight 0.96 kg 0.96 kg 0.96 kg
Ambient conditions
• Max. relative humidity (in %) 95% 95% 95%
• Mounting position Vertical Vertical Vertical
- Max. permissible angle of +/- 90° +/- 90° +/- 90°
inclination without external fan
• Temperature
- Operation (vertical installation) 0 to +50 °C 0 to +50 °C 0 to +50 °C
- Operation 0 to +35 °C 0 to +35 °C 0 to +35 °C
(max. angle of inclination)
- Transportation and storage -25 to +70 °C -25 to +70 °C -25 to +70 °C
Expansions for operator-process
communication
(may only be an option)
• DP direct LEDs S1...S16, K1...K16 K1...K16
(LEDs as S7 output I/O)
• DP direct keys S1...S16, F1...F8, K1...K16 F1...F8, K1...K16
(buttons as input peripherals)
2
54
240 http://www.siemens.com/panels
120 50
35
Note
Do you need a specific modification or option for the products
132
described here? Then look up "Customized products", where
195
204
231
30
G_ST80_XX_00052
■ Overview ■ Design
• 3“ LCD, 160 x 48 pixels, monochrome
• 8 system keys, 4 user-configurable function keys
• Numerical and alphanumeric input option via cursor keys
• Compact design with low mounting depth
• Rugged plastic housing
2
• The front is resistant to various oils, greases and standard
detergents
• Plug-type terminals for a 24 V DC power supply
• RS 485 interface for process connections (MPI, PROFIBUS DP
up to 1.5 Mbit/s) and for configuration download
■ Function
• Input/output fields
for displaying and changing process parameters
• Function keys
for direct triggering of functions and actions. Up to 16 functions
• Operator panel for operator control and monitoring of can be configured simultaneously on function keys.
machines and plants • Graphics
• A new dimension in graphics: small and clever can be used as icons instead of text to "label" function keys or
buttons. They can also be used as simple on-screen graphics.
• Pixel graphics 3" LCD, monochrome In the configuration tool, a library is available containing an
• 8 system keys, 4 freely programmable function keys extensive range of graphics and a wide variety of objects.
• All interfaces (e.g. MPI, PROFIBUS DP) are onboard All editors with an OLE interface can be used as graphics edi-
tors (such as PaintShop, Designer or CorelDraw).
• SIMATIC OP 73 is the successor to the OP3 Operator Panel
• Predefined
for labeling function keys, process images and process values
■ Benefits in different font sizes
• High-contrast display for good readability • Bars are used for the graphical display of dynamic values
• Large keys for high operational safety • Language selection during runtime
- 5 online languages, 32 configuration languages incl. Asian
• Simple handling and configuring and Cyrillic character sets
• Integral component of Totally Integrated Automation (TIA): - Language-dependent texts and graphics
Increases productivity, minimizes the engineering outlay, • User administration (security)
reduces the lifecycle costs - Authentication with user ID and password
• Service-friendly through maintenance-free design (no battery) - User-group-specific rights
and high service life of the backlighting • Message system
• Graphics library is available complete with ready-to-use - Discrete alarms
display objects - Freely definable message classes (e.g., status/fault
• Can be used worldwide: messages) for definition of acknowledgment response and
- 32 languages can be configured (including Asiatic and display of message events
Cyrillic character sets) - Message history
- Up to 5 languages are selectable online • Help texts
- Language-dependent texts and graphics for process images, messages and variables
• Arithmetic functions
■ Application • Limit value monitoring
for reliable process control of inputs and outputs
The OP 73 Operator Panels can be used wherever direct
operator control and monitoring of machines and installations is • Indicator light
required locally – whether in production automation, process for machine and plant status indication
automation or building automation. They are in use in an exten- • Scheduler for global function execution
sive range of sectors and applications. • Template concept;
Compatible with OP3 Creation of screen templates (picture elements configured in
the template appear in every screen)
• Same installation cutout as OP3
• Simple maintenance and configuration thanks to:
• The OP3 configurations can be loaded from ProTool/Lite, - Backup and restoration of configuration, operating system
ProTool and ProTool/Pro and firmware on a PC using ProSave
Migration manual with description of the important differences - Configuration download via MPI/PROFIBUS DP or serially via
over OP3 or ProTool RS485
- Individual contrast settings
- No batteries are necessary
■ Technical specifications
SIMATIC OP 73 SIMATIC OP 73
Display Configuring
• Display type STN liquid crystal display (LCD) • Configuration tool WinCC flexible
• Size 3" Functionality
• Resolution (W x H in pixels) 160 x 48 (with WinCC flexible)
• Colors 2 black/white • Help system Yes
• MTBF of background lighting approx. 100,000 hours Protocols
(at 25 °C)
• Interface to control S7-200, S7-300/400Win AC
Operating mode (may only be an option)
• Operating options Key Signaling system
• Function keys, programmable 4 function keys • Number of messages 500
• Membrane keyboard Yes • Discrete alarms Yes
• System keys 8 • Message length (in characters) 80
• Numeric/alphanumeric input Yes/Yes • Number of process values per 8
Processor/HW ARM message
• Message buffer Ring buffer, 256 entries each
Memory
• Type Flash/RAM Process images 500
• Usable memory for project data 256 KB user memory/without Picture elements
additional memory for options • Text objects 1000 text elements
Interfaces 1 x RS485 max. 1.5 Mbit/s • Fields per screen 20
Supply voltage • Variables/screen 20
• Supply voltage 24 V DC • Graphics objects Bitmaps, icons, icon
(filling the screen)
• Permissible range +20.4 to +28.8 V DC
• Dynamic objects Bar graphs
• Backup battery No
Text lists 150
Clock Software clock, without battery
backup • Libraries Yes
Degree of protection Variables 1000
• Front IP65, NEMA 4, NEMA 12; Security
(when mounted) • Number of user groups 50
• Rear IP20 • Number of access rights 32
Certification CE, GL, ABS, BV, DNV, LRS, PRS, • Exportable passwords Yes
(some only as options) UL, CSA, cULus, C-TICK
Languages
Mechanical components/ • Online languages 5
dimensions
• Project languages: D, GB, F, I, E, CHN "traditional",
• Front panel W x H (mm) 154 x 84 CHN "simplified", DK, FIN, GR, J,
• Mounting cutout/depth W x H x D 138 x 68/28.5 mm depth of unit KP/ROK, NL, N, PL, P, RUS, S,
(mm) CZ/SK, TR, H
• Weight 0.25 kg • Character sets WinCC flexible standard,
ideographic languages
Ambient conditions
• Max. relative humidity (in %) 95% Transfer under ProTool
(upload/download)
• Mounting position Vertical
• Transfer of the configuration MPI/PROFIBUS DP, serial
- Max. permissible angle of +/- 90°
inclination without external fan
• Temperature
- Operation (vertical installation) 0 to +50 °C
- Operation (max. angle of inclin.) 0 to +40 °C
- Transportation and storage -20 to +60 °C
2
http://www.siemens.com/panels
154 28.5
Note
Do you need a specific modification or option for the products
67.7 described here? Then look up "Customized products",
84
■ Overview ■ Application
The OP 77A Operator Panels can be used wherever direct
operator control and monitoring of machines and installations is
required locally – whether in production automation, process
automation or building automation. They are in use in an exten-
sive range of sectors and applications. 2
Compatibility with OP7
• Same mounting cutout as OP7
• The OP7 configurations can be loaded from ProTool/Lite,
ProTool and ProTool/Pro
Migration manual with description of the important differences
over OP7 or ProTool
■ Design
• 4.5" LCD, 160 x 64 pixels, monochrome
• 23 system keys, 8 freely-configurable and freely-inscribable
function keys (4 with LEDs)
• Compact operator panel for operating and monitoring • Numeric and alphanumeric input facilities
machines and plants • Compact design with shallow installation depth
• Together with the OP 77B, it is the successor to the successful • Rugged plastic housing
OP7 • The front is resistant to various oils, greases and standard
• A new dimension in graphics: small and clever detergents
• Pixel graphics 4.5" LCD, monochrome • Plug-type terminals for connection of a 24 V DC power supply
• 23 system keys, 8 freely-configurable and freely-inscribable • RS 485 interface for process links (MPI, PROFIBUS DP up to
function keys (4 with LEDs) 1.5 Mbit/s) and for downloading the configuration
• All interfaces (e.g. MPI, PROFIBUS DP) are onboard
■ Function
■ Benefits • Input/output fields
• High-contrast display for good readability for displaying and changing process parameters
• Large keys for high operational safety • Function keys
for direct triggering of functions and actions. Up to 16 functions
• Simple handling and configuring can be configured simultaneously on function keys.
• Integral component of Totally Integrated Automation (TIA): • Graphics
Increases productivity, minimizes the engineering outlay, can be used as icons instead of text to "label" function keys or
reduces the lifecycle costs buttons. They can also be used as simple on-screen graphics.
• Reduction in service and startup costs thanks to maintenance- In the configuration tool, a library is available containing an ex-
free design (no battery) and long service life of the backlighting tensive range of graphics and a wide variety of objects.
• Can be used worldwide: All editors with an OLE interface can be used as graphics edi-
- 32 languages can be configured (including Asiatic and tors (such as PaintShop, Designer or CorelDraw).
Cyrillic character sets) • Predefined texts
- Up to 5 languages are selectable online for labeling function keys, process images and process values
- Language-dependent texts and graphics in any character size
• Graphics library is available complete with ready-to-use • Bars are used for the graphical display of dynamic values
display objects • Display selection from the PLC
supports operator prompting from the PLC
• Language selection during runtime
- 5 online languages, 32 configuration languages incl. Asian
and Cyrillic character sets
- Language-dependent texts and graphics
• User administration (security) according to the requirements of
the various sectors
- Authentication with user ID and password
- User-group-specific rights
• Signaling system
- Freely definable message classes (e.g., status/fault
messages) for definition of acknowledgment response and
display of message events
- Message history
■ Technical specifications
SIMATIC OP 77A SIMATIC OP 77A
Display Functionality
(with WinCC flexible)
• Display type STN liquid crystal display (LCD)
• Size 4.5"
• Help system
Protocols
Yes
2
• Resolution (W x H in pixels) 160 x 64
• Interface to control S7-200, S7-300/400Win AC
• Colors 2 black/white (may only be an option)
• MTBF of background lighting (at approx. 100,000 hours Signaling system
25 °C)
• Number of messages 1000
Operating mode
• Discrete alarms Yes
• Control elements Membrane keyboard
• Message length (in characters) 80
• Operating options Key
• Number of process values per 8
• Function keys, programmable 8 function keys, 4 with LEDs message
• Membrane keyboard Yes • Message buffer Ring buffer, 256 entries each
• System keys 23 Process images/number
• Numeric/alphanumeric input Yes/Yes • Process images 500
Processor/HW Picture elements
• Processor Not specified, 40 MHz • Text objects 1000 text elements
Memory • Fields per screen 30
• Type Flash/RAM • Variables/screen 30
• Usable memory for project data 256 KB user memory/without • Graphics objects Bitmaps, icons, icon
additional memory for options (filling the screen)
Interfaces 1 x RS422, Text lists 300
1 x RS485 max. 1.5 Mbit/s
• Libraries Yes
Supply voltage
Variables 1000
• Supply voltage 24 V DC
Security
• Permissible range +20.4 to +28.8 V DC
• Number of user groups 50
• Rated current 0.2 A
• Number of access rights 32
Clock Software clock, without battery
backup • Exportable passwords Yes
Degree of protection Languages
• Front IP65, NEMA 4, NEMA 12; • Online languages 5
(when mounted)
• Project languages: D, GB, F, I, E, CHN "traditional",
• Rear IP20 CHN "simplified", DK, FIN, GR, J,
KP/ROK, NL, N, PL, P, RUS, S,
Certification CE, GL, ABS, BV, DNV, LRS, PRS, CZ/SK, TR, H
(some only as options) FM Class I Div. 2, UL, CSA,
cULus, EX zone 2/22, C-TICK • Character sets WinCC flexible standard,
ideographic languages
Mechanical components/
dimensions Transfer under ProTool
(upload/download)
• Front panel W x H (mm) 150 x 186
• Transfer of the configuration MPI/PROFIBUS DP, serial
• Mounting cutout/depth W x H x D 134 x 170/38.5 mm depth of unit (automatic transfer recognition)
(mm)
• Weight 0.5 kg
Ambient conditions
• Max. relative humidity (in %) 95%
• Mounting position Vertical
- Max. permissible angle of incli- +/- 90°
nation without external fan
• Temperature
- Operation (vertical installation) 0 to +50 °C
- Operation 0 to +40 °C
(max. angle of inclination)
- Transportation and storage -20 to +60 °C
Configuring
• Configuration tool WinCC flexible
2
150 38,5
http://www.siemens.com/panels
Note
186
170
6,2
G_ST80_DE_00087
■ Overview ■ Application
The OP 77B Operator Panels can be used wherever direct
operator control and monitoring of machines and installations is
required locally – whether in production automation, process
automation or building automation. They are in use in an exten-
2 sive range of sectors and applications.
Compatibility with OP7
• Same installation cutout as OP7
• The OP7 configurations can be loaded from ProTool/Lite,
ProTool and ProTool/Pro
Migration manual with description of the important differences
over OP7 or ProTool
■ Design
• 4.5" LCD, 160 x 64 pixels, monochrome
• 23 system keys, 8 freely-configurable and freely-inscribable
function keys (4 with LEDs)
• Compact operator panel for operating and monitoring • Numeric and alphanumeric input facilities
machines and plants • Compact design with small installation depth
• Together with the OP 77A it is the successor to the successful • Rugged plastic housing
OP7 • The front is resistant to various oils, greases and standard de-
• A new dimension in graphics: small and clever tergents
• Pixel graphics 4.5" LCD, monochrome • Plug-type terminals for connection of a 24 V DC power supply
• 23 system keys, 8 freely-configurable and freely-inscribable • Interfaces:
function keys (4 with LEDs) - RS 485/422 interface for process connections
• All interfaces (e.g. MPI, PROFIBUS DP) are onboard (MPI and PROFIBUS DP up to 12 Mbit/s)
- RS 232 interface for process connections
• Non-Siemens PLCs can be connected via easy-to-use drivers - USB printer port
• Slot for multi media card (MMC)
■ Benefits
• High-contrast display for good legibility ■ Function
• Large keys for improved operational reliability • Input/output fields
• Easy to handle and configure for displaying and changing process parameters
• Integral component of Totally Integrated Automation (TIA): • Function keys
increases productivity, minimizes the engineering outlay, for direct initiation of functions and actions. Up to 16 functions
reduces the lifecycle costs can be configured simultaneously on function keys. They can
• Reduction of service and commissioning costs through: be used directly as PROFIBUS DP input peripherals.
- Remote downloading of the configuration with automatic • Graphics
transfer recognition even via WAN (Wide Area Network) can be used as icons instead of text to label function keys or
- Maintenance-free design (no battery) and long service life of buttons. They can also be used as simple graphics in the
the backlighting display.
• Can be used all over the world: In the configuration tool, a library is available containing exten-
- 32 languages can be configured (incl. Asian and Cyrillic sive graphics and a wide variety of objects. All editors with an
character sets) OLE interface can be used as graphics editor (such as
- Up to 5 languages can be switched online PaintShop, Designer or CorelDraw).
- Language-dependent texts and graphics • Fixed texts
• Graphics library available with off-the-shelf picture objects for labeling function keys, process diagrams and process
values in any character size
• Standard hardware and software interfaces for increasing
flexibility: • Bar displays for the graphical display of dynamic values
- Optional Multi Media Card, can be used for recipe data sets • Display selection from the PLC
and for backup of configuration/system data supports operator prompting from the PLC
• Integrated printer port (USB) • Language switchover during runtime
- 5 online languages, 32 configuration languages incl. Asiatic
and Cyrillic character sets
- Language-dependent texts and graphics
• User administration (security) according to the requirements of
the various sectors
- Authentication by means of user ID and password
- Privileges specific to user groups
■ Technical specifications
SIMATIC OP 77B SIMATIC OP 77B
Display Functionality
(with WinCC flexible)
• Display type STN liquid crystal display (LCD)
2 • Size 4.5"
• Scheduler
• Help system
Yes
Yes
• Resolution (W x H in pixels) 160 x 64
Protocols
• Colors 2 black/white • Interface to control S5, S7-200, S7-300/400, 505,
• MTBF of background lighting approx. 100,000 hours (may only be an option) Win AC, Allen Bradley (DF1),
(at 25 °C) Mitsubishi (FX), Modicon (Mod-
bus), other non-Siemens drivers
Operating mode
Signaling system
• Control elements Membrane keyboard
• Number of messages 1000
• Operating options Key
• Discrete alarms Yes
• Function keys, programmable 8 function keys, 4 with LEDs • Analog messages Yes
• Membrane keyboard Yes • Message length (in characters) 80
• System keys 23 • Number of process values per 8
message
• Numeric/alphanumeric input Yes/No
• Message buffer Ring buffer, 256 entries each
Processor/HW RISC 32 bits, 200 MHz
Recipes
Operating system Windows CE
• Recipes 100
Memory
• Data records per recipe 200
• Type Flash/RAM • Entries/data record 200
• Usable memory for project data 1000 KB user memory/without • Recipe memory 32 KB integrated Flash,
additional memory for options expandable
Interfaces (some only as options) Process images 500
• Interfaces 1 x RS232, 1 x RS422, Picture elements
1 x RS485 max. 12 Mbit/s
• Text objects 2500 text elements
• USB (universal serial bus) 1 x USB
• Fields per screen 30
• SD/MMC SLOT 1 x MMC slot • Variables/screen 30
Supply voltage • Graphics objects Bitmaps, icons, icon
• Supply voltage 24 V DC (filling the screen)
• Dynamic objects Bar graphs, slides, analog
• Permissible range +20.4 to +28.8 V DC displays, hidden buttons
• Rated current 0.2 A • Number of bar graphs per project 2500
Clock Software clock, without battery • Alphanumeric fields 1000
backup
• Numeric fields 1000
Degree of protection
Text lists 300
• Front IP65, NEMA 4, NEMA 12;
Libraries Yes
(when mounted)
Variables 1000
• Rear IP20
Security
Certification CE, GL, ABS, BV, DNV, LRS, PRS,
(some only as options) FM Class I Div. 2, UL, CSA, • Number of user groups 1000
cULus, EX zone 2/22, C-TICK • Number of access rights 32
Mechanical components/ • Exportable passwords Yes
dimensions
Logging/printer driver
• Front panel W x H (mm) 150 x 186 • Printing/logging Messages, report/log, hard copy
• Mounting cutout/depth W x H x D 134 x 170/38.5 mm depth of unit Languages
(mm)
• Online languages 5
Ambient conditions
• Project languages: D, GB, F, I, E, CHN "traditional",
• Max. relative humidity (in %) 95% CHN "simplified", DK, FIN, GR, J,
KP/ROK, NL, N, PL, P, RUS, S,
• Mounting position Vertical
CZ/SK, TR, H
- Max. permissible angle of +/- 90°
inclination without external fan • Character sets Tahoma, WinCC flexible standard,
ideographic languages,
• Temperature all freely scalable
- Operation (vertical installation) 0 to +50 °C Data carrier support
- Operation 0 to +40 °C (may only be an option)
(max. angle of inclination) • MMC card Yes
- Transportation and storage Up to +°C
Transfer under ProTool
Peripherals Printer (upload/download)
Configuring • Transfer of the configuration MPI/PROFIBUS DP, serial, USB,
using external memory medium
• Configuration tool WinCC flexible (automatic transfer recognition)
A) Subject to export regulations AL: N and ECCN: EAR99H C) Subject to export regulations AL: N and ECCN: EAR99S
B) Subject to export regulations AL: N and ECCN: 5D002ENC3 D) Subject to export regulations AL: N and ECCN: 5D992B1
2
150 38,5
http://www.siemens.com/panels
Note
186
170
134
6,2
G_ST80_DE_00087
■ Overview ■ Design
• STN, CCFL1) backlit display, Bluemode
• Resistive analog Touch
• Numeric "on-screen“ system keyboard for decimal, binary and
hexadecimal numeric formats
• On-screen alphanumeric keyboard
2
• Compact design with shallow installation depth
• Rugged plastic housing
• The front is resistant to various oils, greases and standard
detergents
• A protective cover is available as an option for achieving the
NEMA 4 degree of protection and as additional protection
against fouling and scratching
• Plug-type terminals for connection of a power supply
• Interfaces for plugging the connecting cables into the PLC or
configuration computer are integrated.
■ Technical specifications
SIMATIC TP 170A SIMATIC TP 170A
Display Clock/type
• Display type STN liquid crystal display (LCD) • Clock Software clock, without battery
backup
• Size 5.7"
Degree of protection
• Resolution (W x H in pixels) 320 x 240
• Front IP65, NEMA 4; (when mounted)
• Colors 4 shades of blue
• Rear IP20
• MTBF of background lighting approx. 50,000 hours
(at 25 °C) Certification CE, FM Class I Div. 2, UL, CSA,
(some only as options) cULus
Operating mode
Mechanical components/
• Operating options Touch dimensions
• Touch screen Analog, resistive • Front panel W x H (mm) 212 x 156
• Numeric/alphanumeric input Yes/Yes • Mounting cutout/depth W x H x D 198 x 142/45 mm depth of unit
Processor/HW RISC 32 bits, 66 MHz (mm)
Operating systems Windows CE • Weight 0.7 kg
Memory Ambient conditions
• Type Flash/RAM • Max. relative humidity (in %) 85%
• Usable memory for project data 320 KB user memory/without • Mounting position Vertical
additional memory for options - Max. permissible angle of +/- 35°
Interfaces TTY optional, inclination without external fan
1 x RS232, • Temperature
1 x RS422,
- Operation (vertical installation) 0 to +50 °C
1 x RS485 max. 1.5 Mbit/s
- Operation 0 to +40 °C
Supply voltage (max. angle of inclination)
• Supply voltage 24 V DC - Transportation and storage -20 to +60 °C
• Permissible range +18 V to +30 V DC Configuring
• Rated current 0.24 A • Configuration tool ProTool
• Output 6W • Configuration tool WinCC flexible
2
http://www.siemens.com/panels
212
6
196
Note
Do you need a specific modification or option for the products
described here? Then look up "Customized products",
where you will find information about additional sector-specific
140
156
42
G_ST80_XX_00064
■ Overview ■ Application
The TP 170B Touch Panels can be used in all applications in
which operator control and monitoring of machines and installa-
tions is required on site – whether in production automation, pro-
cess automation or building service automation. They are in use
2 in an extensive range of sectors and applications.
■ Design
• STN, CCFL1)-backlit display, Bluemode or color
• Resistive analog Touch
• Numeric "on-screen“ system keyboard for decimal,
binary and hexadecimal numeric formats
• On-screen alpha keyboard (English font)
• Compact design with shallow installation depth
• Rugged plastic housing
• The front is resistant to various oils, greases and standard
detergents
• A protective cover is available as an option for achieving the
• Touch panel for operating and monitoring machines and plants NEMA 4 degree of protection and as additional protection
• Universal unit for first-time users in the category of touch pan- against fouling and scratching
els with graphics capability with extensive functionality • Plug-type terminals for connection of a power supply
• Pixel graphics STN display Bluemode/color with touch screen • Interfaces for plugging the connecting cables into the PLC,
(analog/resistive) printer or configuration computer are integrated.
• Interfaces for communication with Siemens SIMATIC S7 PLCs • Slot for standard Compact Flash Card
(e.g. MPI, PROFIBUS DP) are on board
• S5 PLCs and non-Siemens PLCs can be connected through 1) Cold Cathode Fluorescence Lamps
easy-to-use drivers or converters
■ Benefits ■ Function
• Input/output fields
• Integral component of Totally Integrated Automation (TIA): for displaying and changing process parameters
increases productivity, minimizes the engineering outlay, re-
duces the lifecycle costs • Buttons
for direct triggering of functions and actions. Up to 16 functions
• Reduction of service and commissioning costs through: can be configured simultaneously on buttons.
- Backup/restoration via a process interface or optionally via a
CompactFlash card • Graphics
- Remote downloading of the configuration with automatic can be used as icons instead of text to "label" function keys or
transfer recognition even via WAN (Wide Area Network) using buttons. They can also be used as background displays (wall-
TeleService adapter paper).
- Maintenance-free design (no battery) and long service life of In the configuration tool, a library is available containing exten-
the backlighting sive graphics and a wide variety of objects. All editors with an
OLE interface can be used as graphics editors (such as Paint-
• Can be used all over the world: Shop, Designer or CorelDraw).
- 32 offline languages can be configured (incl. Asian and Cyril-
lic character sets) • Vector graphics;
- Online language can be selected directly on the device simple geometric basic forms (e.g., lines, circles and rectan-
gles) can be created direct in the configuring tool
• Graphics library available with off-the-shelf picture objects
• Predefined texts
• Standard hardware and software interfaces for increasing for labeling function keys, process images and process values
flexibility: in any character size
- CompactFlash card, used for recipe data records and for
backup of configuration/system data • Curve functions and bars
are used for the display of dynamic values in graphics-based
• Integrated printer port format
• Extensive documentation on the SIMATIC HMI Manual Collec- • Display selection from the PLC
tion CD supports operator prompting from the PLC
• Language selection;
online languages can be selected directly on the device
• Password protection
• Signaling system;
administration of status, fault and system messages.
• Recipe management
- With additional data storage (on CF card)
- Online/offline processing on the panel
- Storage of recipe data in standard Windows format (CSV)
- External processing using standard tools such as Excel and
Access is possible
■ Technical specifications
SIMATIC SIMATIC SIMATIC SIMATIC
TP 170B TP 170B TP 170B TP 170B
Bluemode Color Bluemode Color
(4 levels) (16 colors) (4 levels) (16 colors)
2 Display
• Display type STN liquid STN liquid
Clock Software clock,
without battery
Software clock,
without battery
backup backup
crystal display crystal display
(LCD) (LCD) Degree of protection
• Size 5.7" 5.7" • Front IP65, NEMA 4; IP65, NEMA 4;
(when (when
• Resolution (W x H in pixels) 320 x 240 320 x 240 mounted) mounted)
• Colors 4 shades of 16 colors • Rear IP20 IP20
blue
Certification CE, FM Class I CE, FM Class I
• MTBF of background lighting approx. approx. (some only as options) Div. 2, UL, CSA Div. 2, UL, CSA
(at 25 °C) 50,000 hours 50,000 hours
Mechanical components/
Operating mode dimensions
• Operating options Touch Touch • Front panel W x H (mm) 212 x 156 212 x 156
• Touch screen Analog, Analog, • Mounting cutout/depth W x H x D 198 x 142/ 198 x 142/
resistive resistive (mm) 45 mm depth 45 mm depth
• Numeric/alphanumeric input Yes/Yes Yes/Yes of unit of unit
Processor/HW RISC 32 bits, RISC 32 bits, • Weight 0.7 kg 0.7 kg
66 MHz 66 MHz Ambient conditions
Operating systems Windows CE Windows CE • Max. relative humidity (in %) 85% 85%
Memory • Mounting position Vertical Vertical
• Type Flash/RAM Flash/RAM - Max. permissible angle of +/- 35° +/- 35°
• Usable memory for project data 768 KB user 768 KB user inclination without external fan
memory/with- memory/with- • Temperature
out additional out additional
- Operation (vertical installation) 0 to +50 °C 0 to +50 °C
memory for memory for
options options - Operation 0 to +40 °C 0 to +40 °C
(max. angle of inclination)
Interfaces (some only as options)
- Transportation and storage -20 to +60 °C -20 to +60 °C
• Interfaces TTY optional, TTY optional,
2 x RS232, 2 x RS232, Peripherals/applications/options
1 x RS422, 1 x RS422, • I/O Printer Printer
1 x RS485 1 x RS485
max. 12 Mbit/s max. 12 Mbit/s • Applications/options ThinClient None
(with ProTool)
• CF card slot 1 x CF card slot 1 x CF card slot
Configuring
Supply voltage
• Configuration tool ProTool ProTool
• Supply voltage 24 V DC 24 V DC
• Configuration tool WinCC flexible WinCC flexible
• Permissible range +18 V to +18 V to
+30 V DC +30 V DC
• Rated current 0.25 A 0.25 A
• Output 6W 7W
2
http://www.siemens.com/panels
212
6
196
Note
Do you need a specific modification or option for the products
described here? Then look up "Customized products",
where you will find information about additional sector-specific
140
156
42
G_ST80_XX_00064
■ Overview ■ Design
• 5.7” STN, CCFL1) backlit display, Bluemode (4 levels)
• Resistive analog Touch
• Numeric system keyboard for decimal, binary and hexadeci-
mal number formats
• On-screen alphanumeric keyboard
2
• Compact design with small installation depth
• Rugged plastic housing
• The front is resistant to various oils, greases and standard de-
tergents
• Plug-type terminals for connection of a 24 V DC power supply
• RS 485 interface for process connections (MPI, PROFIBUS DP
to 1.5 Mbit/s) and for configuration download
■ Function
• Input/output fields
for displaying and changing process parameters
• Buttons
• Touch panel for operator control and monitoring of small for direct triggering of functions and actions. Up to 16 functions
machines and plants can be configured simultaneously on buttons.
• Low-cost starter device in the touch panel class with graphical • Graphics
capability complete with all the basic functions required for can be used as icons instead of text to "label" function keys or
simple tasks buttons. They can also be used as background displays (wall-
• Pixel graphics 5.7" STN touch screen (analog/resistive), paper).
Bluemode (4 levels) In the configuration tool, a library is available containing exten-
• All interfaces (e.g. MPI, PROFIBUS DP) are on board sive graphics and a wide variety of objects. All editors with an
• SIMATIC TP 177A is the redesigned TP 170A Touch Panel OLE interface can be used as graphics editors (such as Paint-
Shop, Designer or CorelDraw).
• Vector graphics
■ Benefits Simple geometric basic forms (line, circle and rectangle) can
• Can even be used where installation space is restricted thanks be created direct in the configuring tool
to portrait configuration • Predefined
• Integral component of Totally Integrated Automation (TIA): for labeling function keys, process images and process values
Increases productivity, minimizes the engineering outlay, in different font sizes
reduces the lifecycle costs • Bars
• Reduces the service and start-up costs due to: for the graphical display of dynamic values
- Remote downloading of configuration with automatic transfer • Language selection:
recognition also over WAN (Wide Area Network) - 5 online languages, 32 configuration languages incl. Asian
- Maintenance-free design (no batteries) and the long service and Cyrillic character sets
life of the backlighting - Language-dependent texts and graphics
• Graphics library is available complete with ready-to-use • User administration (security) according to the requirements of
display objects the various sectors
• Can be used worldwide: - Authentication with user ID and password
- 32 languages can be configured (including Asiatic and - User-group-specific rights
Cyrillic character sets) • Signaling system
- Up to 5 languages are selectable online - Discrete alarms
- Language-dependent texts and graphics - Freely-definable message classes (e.g., status/fault
messages) for definition of acknowledgment response and
display of message events
■ Application - Message history
The TP 177A Touch Panels can be used wherever direct opera-
tor control and monitoring of small machines and installations is
required locally – whether in production automation, process
automation or building automation. They are in use in an exten-
sive range of sectors and applications.
With its quick response times, the TP 177A is also ideally suited
to jog mode.
Compatible to TP 170A
• Installation cutout identical to TP 170A
• The TP 170A configurations can be loaded from ProTool/Lite,
ProTool and ProTool/Pro
• Migration manual with descriptions of the main differences
over TP 170A or ProTool
■ Technical specifications
SIMATIC TP 177A SIMATIC TP 177A
Display Functionality
(with WinCC flexible)
• Display type STN liquid crystal display (LCD)
• Size 5.7"
• Help system
Protocols
Yes
2
• Resolution (W x H in pixels) 320 x 240
• Interface to control S7-200, S7-300/400Win AC
• Colors 4 shades of blue (may only be an option)
• MTBF of background lighting approx. 50,000 hours Signaling system
(at 25 °C)
• Number of messages 1000
Operating mode
• Discrete alarms Yes
• Operating options Touch
• Analog messages No
• Touch screen Analog, resistive
• Message length (in characters) 80
• Numeric/alphanumeric input Yes/Yes
• Number of process values per 8
Processor/HW N/A message
Memory • Message buffer Ring buffer, 256 entries each
• Type Flash/RAM Process images 250
• Usable memory for project data 512 KB user memory/without Picture elements
additional memory for options
• Text objects 1000 text elements
Interfaces 1 x RS422,
1 x RS485 max. 1.5 Mbit/s • Fields per screen 30
Supply voltage • Variables/screen 30
• Supply voltage 24 V DC • Graphics objects Bitmaps, icons, icon
(filling the screen)
• Permissible range +20.4 to +28.8 V DC
• Dynamic objects Bar graphs
• Output 6W
Text lists 300
Clock Software clock,
without battery backup Graphics lists 0
Degree of protection Libraries Yes
• Front IP65, NEMA 4, NEMA 12; Variables 250
(when mounted)
Security
• Rear IP20
• Number of user groups 50
Certification CE, GL, ABS, BV, DNV, LRS, PRS,
(some only as options) FM Class I Div. 2, UL, CSA, • Number of access rights 32
cULus, hazardous zone 2/22, • Exportable passwords Yes
C-TICK
Languages
Mechanical components/
dimensions • Online languages 5
• Front panel W x H (mm) 212 x 156 • Project languages: D, GB, F, I, E, CHN "traditional",
CHN "simplified", DK, FIN, GR, J,
• Mounting cutout/depth W x H x D 198 x 142/45 mm depth of unit KP/ROK, NL, N, PL, P, RUS, S,
(mm) CZ/SK, TR, H
• Weight 0.75 kg • Fonts WinCC flexible standard,
Ambient conditions ideographic languages
• French 6AV6 691-1DG01-0AC1 A) Subject to export regulations AL: N and ECCN: EAR99H
• Italian 6AV6 691-1DG01-0AD1 B) Subject to export regulations AL: N and ECCN: 5D002ENC3
• Spanish 6AV6 691-1DG01-0AE1 C) Subject to export regulations AL: N and ECCN: EAR99S
User Manual
WinCC flexible Compact/Stand
ard/Advanced
• German 6AV6 691-1AB01-0AA0
• English 6AV6 691-1AB01-0AB0
• French 6AV6 691-1AB01-0AC0
• Italian 6AV6 691-1AB01-0AD0
• Spanish 6AV6 691-1AB01-0AE0
User Manual
WinCC flexible Communication
• German 6AV6 691-1CA01-0AA0
• English 6AV6 691-1CA01-0AB0
SIMATIC HMI C 6AV6 691-1SA01-0AX0
Manual Collection
Electronic documentation,
on CD-ROM
5 languages (English, French,
German, Italian and Spanish);
contains: all currently available
user manuals, manuals and
communication manuals for
SIMATIC HMI
2
44 http://www.siemens.com/panels
212
6.2
Note
Do you need a specific modification or option for the products
140
156
■ Overview ■ Application
Thanks to their practical functions and large user memory,
TP 177B Touch Panels can be used wherever operator control
and monitoring of machines and plants is necessary on site –
whether in production automation, process automation or build-
2 ing-services automation. The TP 177B panels are now available
with a 4-color blue-mode display or a 256-color STN display.
The color variant complete with an integral PROFINET interface
can be implemented with even greater flexibility. A USB port
is standard on both model types. A further highlight is the non-
volatile message buffer included as standard that stores
messages permanently without battery backup.
■ Design
• 256 colors with color display or 4 blue-mode monochrome
STN display
• CCFL1)Backlighting with long service life
• Analog resistive touch screen
• Numeric and alphanumeric on-screen keyboard
• High performance thanks to Risk processor and 2 MB user
memory, plus additional integrated recipe memory
• Touch Panel with comprehensive functions for operator control • Data in the message buffer are retained even when panel is
and monitoring of machines and plants disconnected from the power supply, without batteries
• Pixel-graphics STN blue-mode/color display with analog touch • MPI, PROFIBUS DP interfaces (up to 12 Mbaud) as well as
screen USB 1.1 (max. 100 mA) on-board
• Interfaces for communication with Siemens SIMATIC S7 • PROFINET interface with color variant already on-board
(e.g., MPI, PROFIBUS DP) are on-board • Integral USB interface
• PROFINET interface is already on-board in the color version • Can be configured using SIMATIC WinCC flexible 2005 Com-
• Drivers are also available for non-Siemens PLCs pact and higher
• Complete functionality for demanding tasks
■ Benefits • Comprehensive Reichert graphics library
• 32 languages (e.g., Cyrillic, traditional Chinese, simplified
• Reduction of service and commissioning costs through: Chinese) and online switching between up to 5 languages
- Backup/restore via a process interface or optionally via a
Multi Media Card. • Multi Media Card slot, can be used for standard MMCs (for
- Image and configuration download via all device interfaces backing up recipe data sets, the configuration and system
- Maintenance-free design and long service life of the back- data)
lighting. The data in the message buffer are retained even • Remote downloading of the configuration via all interfaces with
when the panel is disconnected from the supply, without automatic transfer recognition
battery backup • SINUMERIK, Sm@rt Access and Sm@rt Service options can be
• Can be used all over the world: used
- 32 project languages can be configured (incl. Asian and • Service-friendly thanks to maintenance-free design and long
Cyrillic character sets) service life of the backlighting display
- Online language can be selected directly on the device
• Graphics library available with off-the-shelf picture objects
1) Cold Cathode Fluorescence Lamps
• Standard interfaces for increasing the flexibility:
- external Multi Media Card, used for recipe data sets and for
backup of configuration/system data
• Integrated USB interface for connecting, for example, stan-
dard printers
• Simple engineering supported with comprehensive documen-
tation on the SIMATIC HMI Manual Collection CD
• Integral component of Totally Integrated Automation (TIA):
increases productivity, minimizes the engineering outlay,
reduces the lifecycle costs
■ Function
• Permanent window and template concept for creating screen Configuring
templates
The equipment is configured using the innovative engineering
• Input/output fields tool SIMATIC WinCC flexible 2005 (Compact and above).
for visualizing and editing process parameters SIMATIC WinCC flexible is the logical further development of the
• Configurable buttons field-proven ProTool family. Projects generated using ProTool
can be easily migrated to WinCC. When OP17 projects are
2
with up to 16 functions are also used to directly trigger func-
tions and actions implemented, the project engineer must make certain changes
• Indicator light following conversion as a result of the innovated display
for machine and plant status indication technology. Support is however provided by WinCC flexible.
If WinCC flexible is started directly from SIMATIC Manager, data
• Predefined texts in STEP 7 can be accessed directly at the click of a mouse but-
for labeling function keys, process images and process values ton when the panel is configured. Duplicated data input and
in any character size data management is, therefore, avoided.
• Help texts
for process images, messages and variables Additional options
• Vector graphics, graphics • SINUMERIK
can be used as icons instead of text for "labeling" buttons. Optionally with "SINUMERIK HMI copy license
They can also be used as full-screen background pictures. WinCC flexible CE". The SINUMERIK HMI engineering
In the configuration tool, a library is available containing exten- WinCC flexible package is also required for configuration.
sive graphics and a wide variety of objects. All editors with an For further information see Catalog NC 60.
OLE interface (e.g., PaintShop, Designer or CorelDraw) can • Sm@rt Service
be used as graphics editors. Remote operator control and monitoring of SIMATIC HMI
• Curve functions and bars systems based on TCP/IP networks
are used for the display of dynamic values in graphics-based • Sm@rt Access
format Communication between HMI systems based on TCP/IP
• Dynamic positioning of objects and dynamic showing/hiding of networks. Remote access to recipe data sets, passwords and
objects information specific to the HMI system, and much more.
• Arithmetic functions, limit value monitoring
for reliable process control with inputs and outputs
• Online language selection (5 selectable languages), incl.
Asian and Cyrillic languages
This also applies to language-specific graphics
• Timer
for cyclic function processing
• Password protection (security)
User management – Authentication by means of user ID and
password plus privileges specific to user groups, which is an
integral part of SIMATIC
• Signaling system
Freely definable message classes (acknowledgement behav-
ior and display can be configured) Administration of status,
fault and system messages. The message history is retained
even if the device is switched off.
Analog alarms (limit value messages) in addition to bit mes-
sages
• Recipe management:
- With additional data storage (on ext. storage medium)
- Online/offline processing on the panel
- Storage of recipe data in standard Windows format (CSV)
- External processing using standard tools such as Excel and
Access is possible
• Multi Media Card slot
for external standard data carrier, can be used for
backup/restoration or for transporting recipe data records
• User-friendly maintenance and configuration thanks to:
- Backup and restoration of the configuration, operating sys-
tem, data records and firmware on a PC using ProSave
- Option to download/upload the configuration via all device
interfaces (with automatic transfer detection)
- Individual contrast setting and calibration
- Clean screen function to support reliable cleaning of the
touch panel in service
- Configuration simulation directly on the configuration com-
puter
■ Technical specifications
SIMATIC SIMATIC SIMATIC SIMATIC
TP 177B TP 177B TP 177B TP 177B
Bluemode Color Bluemode Color
(4 levels) (256 colors) (4 levels) (256 colors)
2 Display Degree of protection
• Display type STN liquid crys- STN liquid crys- • Front IP65, NEMA 4, IP65, NEMA 4,
tal display tal display NEMA 4x, NEMA 4x,
(LCD) (LCD) NEMA 12; NEMA 12;
(when (when
• Size 5.7" 5.7" mounted) mounted)
• Resolution (W x H in pixels) 320 x 240 320 x 240 • Rear IP20 IP20
• Colors 4 shades of 256 colors Certification CE, GL, ABS, CE, GL, ABS,
blue (some only as options) BV, DNV, LRS, BV, DNV, LRS,
• MTBF of background lighting (at approx. 50,000 approx. 50,000 PRS, FM Class I PRS, FM Class I
25 °C) hours hours Div. 2, UL, CSA, Div. 2, UL, CSA,
cULus, EX zone cULus, EX zone
Operating mode 2/22, Gost-R, C- 2/22, Gost-R, C-
• Operating options Touch Touch TICK TICK
• Numeric/alphanumeric input Yes/Yes Yes/Yes • Front panel W x H (mm) 212 x 156 212 x 156
• External mouse/keyboard/bar- USB/USB/- USB/USB/- • Mounting cutout/depth W x H x D 189 x 142/45 189 x 142/45
code reader (mm) mm depth of mm depth of
unit unit
Processor/HW RISC 32 bits, RISC 32 bits,
66 MHz 66 MHz Ambient conditions
Operating systems Windows CE Windows CE • Max. relative humidity (in %) 85% 85%
• Spanish 6AV6 691-1AB01-0AE0 B) Subject to export regulations AL: N and ECCN: 5D002ENC3
User Manual C) Subject to export regulations AL: N and ECCN: EAR99S
WinCC flexible Communication D) Subject to export regulations AL: N and ECCN: 5D992B1
• German 6AV6 691-1CA01-0AA0
• English 6AV6 691-1CA01-0AB0
SIMATIC HMI C 6AV6 691-1SA01-0AX0
Manual Collection
Electronic documentation,
on CD-ROM
5 languages (English, French,
German, Italian and Spanish);
contains: all currently available
user manuals, manuals and
communication manuals for
SIMATIC HMI