Absolute position detection data
Command Data type Description PS AX RW Range
M_SSEC_ABS_DETECT_TYPE T_CHAR Absolute position detection type R
M_SSEC_ABS_DETECT_STATE T_CHAR Absolute position detection status R
M_SSEC_ABS_DETECT_EG T_FLOATBIN/T_LONG Machine end RW
M_SSEC_ABS_DETECT_MAC T_FLOATBIN/T_LONG Machine value RW
M_SSEC_ABS_DETECT_PASS T_LONG Yet to pass (Machine value status) R
M_SSEC_ABS_DETECT_MESS T_CHAR Automatic initial setting message R
M_SSEC_ABS_DETECT_SET T_CHAR Executing initial absolute position R
setting
M_SSEC_ABS_DETECT_REF_POINT T_CHAR Absolute position reference position RW
set
M_SSEC_ABS_DETECT_SET_ABS_POS T_CHAR Absolute position set RW
M_SSEC_ABS_DETECT_ZERO T_FLOATBIN/T_LONG Absolute position zero point RW

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 1 of 206
inventcom

Absolute position parameter


Command Data type Description PS AX RW Range
M_SSEC_MPABSP_ABSTYPM T_CHAR Absolute position detection method -- O RW 0 to 10
M_SSEC_MPABSP_ABSTYP T_LONG Reference Z- direction -- O RW 0,1
M_SSEC_MPABSP_ABSLMT T_FLOATBIN/T_LONG Check -- O RW 0 to 99999.999
M_SSEC_MPABSP_ABSG28 T_SHORT G28 verification width -- O RW 0 to 65535
M_SSEC_MPABSP_ABSM02 T_SHORT M02 verification width -- O RW 0 to 65535
M_SSEC_MPABSP_CLPUSH T_SHORT Current limit (%) -- O RW 0 to 100
M_SSEC_MPABSP_PUSHF T_SHORT Stopper speed -- O RW 1 to 999
M_SSEC_MPABSP_APPROCH T_FLOATBIN/T_LONG Approach -- O RW 0 to 999.999
M_SSEC_MPABSP_NREFP T_FLOATBIN/T_LONG Near reference position + -- O RW 0 to 32.767
M_SSEC_MPABSP_NREFN T_FLOATBIN/T_LONG Near reference position -- O RW 0 to 32.767
M_SSEC_MPABSP_ABSZRBA T_CHAR Select basic point of reference position -- O RW 0,1
parameter
M_SSEC_MPABSP_MLIMIT1BL T_FLOATBIN/T_LONG Soft limit IB -- O RW ±99999.999
M_SSEC_MPABSP_MLIMIT1BU T_FLOATBIN/T_LONG Soft limit IB+ -- O RW ±99999.999
M_SSEC_MPABSP_MOT1TYPE T_CHAR Soft limit IB type -- O RW 0 to 3

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 2 of 206
inventcom

Anshin-net 1
Command Data type Description PS AX RW Range
M_SSEC_MPANET1_CALLBACK_NUM1 T_STR Telephone number to contact 1 -- -- RW Within 28 letters
M_SSEC_MPANET1_CALLBACK_COM1 T_STR Comment1 -- -- RW Within 20 letters
M_SSEC_MPANET1_CALLBACK_NUM2 T_STR Telephone number to contact 2 -- -- RW Within 28 letters
M_SSEC_MPANET1_CALLBACK_COM2 T_STR Comment2 -- -- RW Within 20 letters
M_SSEC_MPANET1_CALLBACK_NUM3 T_STR Telephone number to contact 3 -- -- RW Within 28 letters
M_SSEC_MPANET1_CALLBACK_COM3 T_STR Comment3 -- -- RW Within 20 letters
M_SSEC_MPANET1_ENABLE_ANET T_CHAR Anshin-net enabled -- -- RW 0,1
M_SSEC_MPANET1_ENABLE_KNET T_LONG MTB-net enabled - -- RW 0,1
M_SSEC_MPANET1_PASSWD T_STR Password in machining data share - - RW 4 letters (Alphanumeric
characters, excluding space)
M_SSEC_MPANET1_CUSTOMER_NUM T_STR Customer No. in machining data share - - RW 8 letters (Alphanumeric
characters, excluding space)

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 3 of 206
inventcom

Anshin-net 2
Command Data type Description PS AX RW Range
M_SSEC_MPANET2_MODEM_NUM T_STR Modem's telephone number -- -- RW Within 28 letters
M_SSEC_MPANET2_CALL_NUM T_STR Call centre’s telephone No. -- -- RW Within 28 letters
M_SSEC_MPANET2_KOUKI_NUM T_STR MTB’s telephone No. -- -- RW Within 28 letters
M_SSEC_MPANET2_ARV_CALL_NUM1 T_STR Num arrival call 1 -- -- RW Within 28 letters
M_SSEC_MPANET2_ARV_CALL_NUM2 T_STR Num arrival call 2 -- -- RW Within 28 letters
M_SSEC_MPANET2_ARV_CALL_NUM3 T_STR Num arrival call 3 -- -- RW Within 28 letters
M_SSEC_MPANET2_ARV_CALL_NUM4 T_STR Num arrival call 4 -- -- RW Within 28 letters
M_SSEC_MPANET2_ARV_CALL_NUM5 T_STR Num arrival call 5 -- -- RW Within 28 letters
M_SSEC_MPANET2_ARV_KOUKI_NUM(x) T_STR MTB's num arrival call (x=1 to 5) -- -- RW Within 28 letters
M_SSEC_MPANET2_RETRY T_SHORT Number of times to retry -- -- RW 0 to 255
M_SSEC_MPANET2_ENABLE_ANET T_CHAR Automatic selection of Anshin net -- -- RW 0,1
screen
M_SSEC_MPANET2_COND_KIND1 T_STR Condition 1 (Kind/Register) -- -- RW Within 5 letters
M_SSEC_MPANET2_COND_NUM1 T_STR Condition 1 (No./Status value) -- -- RW Within 4 letters
M_SSEC_MPANET2_COND_KIND2 T_STR Condition 2 (Kind/Register) -- -- RW Within 5 letters
M_SSEC_MPANET2_COND_NUM2 T_STR Condition 2 (No./Status value) -- -- RW Within 4 letters
M_SSEC_MPANET2_COND_KIND3 T_STR Condition 3 (Kind/Register) -- -- RW Within 5 letters
M_SSEC_MPANET2_COND_NUM3 T_STR Condition 3 (No./Status value) -- -- RW Within 4 letters
M_SSEC_MPANET2_COND_KIND4 T_STR Condition 4 (Kind/Register) -- -- RW Within 5 letters
M_SSEC_MPANET2_COND_NUM4 T_STR Condition 4 (No./Status value) -- -- RW Within 4 letters
M_SSEC_MPANET2_COND_KIND5 T_STR Condition 5 (Kind/Register) -- -- RW Within 5 letters
M_SSEC_MPANET2_COND_NUM5 T_STR Condition 5 (No./Status value) -- -- RW Within 4 letters
M_SSEC_MPANET2_COND_KIND6 T_STR Condition 6 (Kind/Register) -- -- RW Within 5 letters
M_SSEC_MPANET2_COND_NUM6 T_STR Condition 6 (No./Status value) -- -- RW Within 4 letters
M_SSEC_MPANET2_COND_KIND7 T_STR Condition 7 (Kind/Register) -- -- RW Within 5 letters
M_SSEC_MPANET2_COND_NUM7 T_STR Condition 7 (No./Status value) -- -- RW Within 4 letters
M_SSEC_MPANET2_COND_KIND8 T_STR Condition 8 (Kind/Register) -- -- RW Within 5 letters
M_SSEC_MPANET2_COND_NUM8 T_STR Condition 8 (No./Status value) -- -- RW Within 4 letters
M_SSEC_MPANET2_COND_KIND9 T_STR Condition 9 (Kind/Register) -- -- RW Within 5 letters
M_SSEC_MPANET2_COND_NUM9 T_STR Condition 9 (No./Status value) -- -- RW Within 4 letters
M_SSEC_MPANET2_COND_KIND10 T_STR Condition 10 (Kind/Register) -- -- RW Within 5 letters
M_SSEC_MPANET2_COND_NUM10 T_STR Condition 10 (No./Status value) -- -- RW Within 4 letters

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 4 of 206
inventcom

M_SSEC_MPANET2_CMD_TIMEOUT T_LONG Command timeout period -- -- RW 0 to 65535


M_SSEC_MPANET2_INT_REDIAL T_LONG Redial interval (s) -- -- RW 0 to 65535
M_SSEC_MPANET2_FRQ_REDIAL T_SHORT Number of times to redial -- -- RW 0 to 255
M_SSEC_MPANET2_MODEM_PORT T_CHAR Modem connection port -- -- RW 1 to 2
M_SSEC_MPANET2_DIAL_MODEM T_CHAR Dial mode selection -- -- RW 0 to 2
M_SSEC_MPANET2_CALLBACK_WAIT T_UCHAR Call wait time -- -- RW 0 to 90
M_SSEC_MPANET2_MACHINE_NO T_STR Machine No. -- -- RW 15 letters (Alphanumeric
characters)

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 5 of 206
inventcom

Anshin-net I/F
Command Data type Description PS AX RW Range
M_SSEC_ANETIF_CALL T_CHAR One-touch call -- -- RW 0,1
M_SSEC_ANETIF_NOTICEOP T_CHAR Operator notice -- -- RW 0,1
M_SSEC_ANETIF_OPTIONALNO T_STR Arbitrary No. -- -- RW 28 letters (Numerical, "#", "*", "-")
M_SSEC_ANETIF_CALLSEL T_CHAR Notice telephone No. -- -- RW 1 to 4
M_SSEC_ANETIF_ANETMSGSTS T_CHAR Anshin-net message status -- -- R 0 to 8
M_SSEC_ANETIF_HOSTMSG T_STR Message from NC service -- -- R 74*5 letters
M_SSEC_ANETIF_COMMSTS T_CHAR Anshin-net communication situation -- -- R 0 to 11,99
M_SSEC_ANETIF_NET_STS T_CHAR Anshin-net communication status -- -- RW 0 to 10/Set 0
M_SSEC_ANETIF_NET_COMMAND T_SHORT Anshin-net/MTB-net communication -- -- R 0 to 7
command
M_SSEC_ANETIF_NS_COMMODE T_CHAR Anshin-net communication mode -- -- R 0 to
M_SSEC_ANETIF_ERRNO T_SHORT Anshin-net/MTB-net error code -- -- R 0: No error, 1 - : Error code
M_SSEC_ANETIF_CHGSTS T_CHAR Screen change status -- -- RW Get: 0,1/Set: 0
M_SSEC_ANETIF_CHGREST T_CHAR Screen change restriction information -- -- R 1,2
M_SSEC_ANETIF_DIAG_INFO_SEND T_LONG MTB-net diagnosis information - -- W 1
transmission
M_SSEC_ANETIF_WARN_CANCEL T_LONG MTB-net warning cancel - -- W 1
M_SSEC_ANETIF_MESS_RECV T_STR MTB-net message reception - -- R 355 letters (71 lines * 5 digits)
M_SSEC_ANETIF_KNET_COMMSTS T_CHAR MTB-net communication situation - -- R 0 to 12,99
M_SSEC_ANETIF_KNET_STS T_CHAR MTB-net communication status - -- RW 0 to 10/Setting 0
M_SSEC_ANETIF_KNET_NS_COMMODE T_CHAR MTB-net communication mode - -- R 0 to 8
M_SSEC_ANETIF_DEV_NAME T_STR Device name for transmission in - - W Within 8 letters
machining data share
M_SSEC_ANETIF_DIR_NAME T_STR Directory name for transmission in - - W Within 80 letters
machining data share
M_SSEC_ANETIF_FILE_NAME T_STR File name for transmission in machining - - W Within 32 letters
data share
M_SSEC_ANETIF_FILE_SIZE T_LONG File size for transmission in machining - - W 0 to 2147483647
data share
M_SSEC_ANETIF_DEV_FREE_SIZE T_LONG Remaining capacity of device for - - W 0 to 2147483647
transmission in machining data share
M_SSEC_ANETIF_ANET_FILE_NAME_PUT T_STR File name of Anshin-net server for - - W Only numericals, within 10 letters
sending in machining data share

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 6 of 206
inventcom

M_SSEC_ANETIF_ANET_FILE_NAME_GET T_STR File name of Anshin-net server for - - W Only numericals, within 11 letters
reception in machining data share
M_SSEC_ANETIF_ANET_FILE_NAME_DEL T_STR File name of Anshin-net server for - - W Only numericals, within 12 letters
deletion in machining data share
M_SSEC_ANETIF_REQ_STS T_UCHAR Get execution request status by each - - R 0 to 0xFF
function fo Anshin-net and MTB-net

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 7 of 206
inventcom

Auxiliary axis control


Command Data type Description PS AX RW Range
M_SSEC_AUX_OPETEST_MODE T_CHAR Operation test mode -- O RW
M_SSEC_AUX_ABS_POS_INIT T_CHAR Absolute position set -- O RW
M_SSEC_AUX_POS_SET_TYP T_CHAR Position setting method -- O R
M_SSEC_AUX_POS_SET_STS T_CHAR Position setting status -- O R
M_SSEC_AUX_OPE_MODE T_CHAR Operation mode -- O RW
M_SSEC_AUX_PARAM_SET T_CHAR Operation parameter group -- O RW
M_SSEC_AUX_SCALE T_SHORT Scale -- O RW
M_SSEC_AUX_OPE_STATE T_CHAR Operation status -- O RW
M_SSEC_AUX_ORIGIN_SET T_CHAR Auxiliary axis reference position set -- O RW
M_SSEC_AUX_SRAM_BACKUP T_CHAR Auxiliary axis parameter SRAM backup -- -- W 0: DRAM->SRAM 1: SRAM-
>DRAM/Drive unit

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 8 of 206
inventcom

Auxiliary axis drive unit monitor


Command Data type Description PS AX RW Range
M_SSEC_MAUX_DROOP T_LONG Droop -- O R
M_SSEC_MAUX_REV_SPD T_SHORT Rotation speed -- O R
M_SSEC_MAUX_CURRENT T_SHORT Load current -- O R
M_SSEC_MAUX_MAX_CUR1 T_SHORT MAX current 1 -- O R
M_SSEC_MAUX_MAX_CUR2 T_SHORT MAX current 2 -- O R
M_SSEC_MAUX_OVER_LOAD T_SHORT Overload -- O R
M_SSEC_MAUX_OVER_REG T_SHORT Regenerative load -- O R
M_SSEC_MAUX_CUR_STN T_SHORT Current station No. -- O R
M_SSEC_MAUX_MAC_POS T_LONG Current position -- O R
M_SSEC_MAUX_INST_STN T_LONG Target station No. -- O R
M_SSEC_MAUX_INST_POS T_LONG Command position -- O R
M_SSEC_MAUX_AUX_NAME T_STR Auxiliary axis name -- O R
M_SSEC_MAUX_POS_CON_GAIN1 T_SHORT Position control gain 1 -- O R
M_SSEC_MAUX_SPEED_CON_GAIN1 T_SHORT Speed control gain 2 -- O R
M_SSEC_MAUX_POS_CON_GAIN2 T_SHORT Position control gain 1 -- O R
M_SSEC_MAUX_SPEED_CON_GAIN2 T_SHORT Speed control gain 2 -- O R
M_SSEC_MAUX_SPEED_INT_COMP T_SHORT Speed integral compensation -- O R
M_SSEC_MAUX_LOAD_INERTIA T_DOUBLE Load inertia ratio -- O R
M_SSEC_MAUX_UNIT_TYP T_STR Drive unit type -- O R
M_SSEC_MAUX_SW_VER T_STR Software version -- O R
M_SSEC_MAUX_MOTOR T_STR Motor type -- O R
M_SSEC_MAUX_ALARM1 T_STR Alarm 1 -- O R
M_SSEC_MAUX_ALARM2 T_STR Alarm 2 -- O R
M_SSEC_MAUX_ALARM3 T_STR Alarm 3 -- O R
M_SSEC_MAUX_ALARM4 T_STR Alarm 4 -- O R
M_SSEC_MAUX_UNIT_NO T_STR Unit serial No. -- O R 8 letters
M_SSEC_MAUX_ALM_HIST_NO(x) T_STR Alarm history 1 to 6 (Alarm No.) (x=1 to -- O R
6)
M_SSEC_MAUX_ALM_HIST_INF(x) T_STR Alarm history 1 to 6 (Detailed alarm -- O R
information) (x=1 to 6)
M_SSEC_MAUX_ALM_HIST(x) T_STR Alarm history 1 to 6 (x=1 to 6) -- O R

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 9 of 206
inventcom

Axis parameter
Command Data type Description PS AX RW Range
M_SSEC_AXISPRM_NAME T_STR Axis name O O RW 1 letter
M_SSEC_AXISPRM_DSP_NAME T_STR Display axis name O O RW 2 letters
M_SSEC_AXISPRM_INCNAME T_STR Increment command axis name O O RW 1 letter
M_SSEC_AXISPRM_CS T_LONG Command unit O O RW 0,1,2,10,20,50,100,1000,10000,
etc.
M_SSEC_AXISPRM_IOUT T_LONG Inch output O O RW 0,1
M_SSEC_AXISPRM_ROT T_LONG Rotary axis O O RW 0,1
M_SSEC_AXISPRM_CCW T_LONG Motor ccw O O RW 0,1
M_SSEC_AXISPRM_DIA T_LONG Diameter specification axis O O RW 0,1
M_SSEC_AXISPRM_SPAX T_LONG Spindle interpolation O O RW 0,1
M_SSEC_AXISPRM_MCP_NO T_SHORT Drive unit interface channel No. O O RW 0x0, 0x101 to 0x107, 0x201 to
0x207
M_SSEC_AXISPRM_CRS_ADR T_STR Command address during cross O O RW 0, A to Z
machining
M_SSEC_AXISPRM_CRS_INC T_STR Incremental command address during O O RW 0, A to Z, other than the address
cross machining already used in the part system
M_SSEC_AXISPRM_INTABS T_LONG Manual ABS updating O O RW 0,1
M_SSEC_AXISPRM_TCOMP T_CHAR Tool compensation function O O RW 0 to 3
M_SSEC_AXISPRM_MANDOG T_LONG Manual dog-type O O RW 0,1
M_SSEC_AXISPRM_SVOF T_LONG Error correction O O RW 0,1
M_SSEC_AXISPRM_JOGH T_CHAR JOG response type O O RW 0 to 4
M_SSEC_AXISPRM_JOGHP T_SHORT Select JOG activation (+) device O O RW Device No. (0 to 5119)
M_SSEC_AXISPRM_JOGHN T_SHORT Select JOG activation (-) device O O RW Device No. (0 to 5119)
M_SSEC_AXISPRM_TSLVNO T_CHAR Slave axis number O O RW 0 to 4
M_SSEC_AXISPRM_NO_DSP T_LONG No_dsp O O RW 0,1
M_SSEC_AXISPRM_AXOFF T_LONG Axis removal O O RW 0,1
M_SSEC_AXISPRM_JOGD T_CHAR ±JOG activation signal device name O O RW 0 to 2
M_SSEC_AXISPRM_CHOP_AX T_LONG Chopping axis O O RW 0,1
M_SSEC_AXISPRM_OUTUNIT T_STR Output unit (Servo) O O RW B,C,D,E
M_SSEC_AXISPRM_REF_SYN T_LONG Synchronization at zero point O O RW 0 to 1
initialization
M_SSEC_AXISPRM_DSP_AX_CHG T_CHAR Axis order of counter display O O RW 0 to 8
M_SSEC_AXISPRM_RAPID T_LONG Rapid O O RW 1 to 1000000

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 10 of 206
inventcom

M_SSEC_AXISPRM_CRUMP T_LONG Cutting feedrate for clamp function O O RW 1 to 1000000


M_SSEC_AXISPRM_SMGST T_SHORT Acceleration and deceleration mode O O RW 0x0000 to 0x7FFF
M_SSEC_AXISPRM_LG0T T_SHORT G0 time constant (Linear) 1st step of O O RW 1 to 4000
soft acc/dec
M_SSEC_AXISPRM_G0T T_SHORT G0 time constant (Primary delay) 2nd O O RW 1 to 5000
step of soft acc/dec
M_SSEC_AXISPRM_G02T T_SHORT G0 time constant (Soft acc/dec) (M7Not O O RW 1 to 5000
used)
M_SSEC_AXISPRM_LG1T T_SHORT G1 time constant (Linear) 1st step of O O RW 1 to 4000
soft acc/dec
M_SSEC_AXISPRM_G1T T_SHORT G1 time constant (Primary delay) 2nd O O RW 1 to 5000
step of soft acc/dec
M_SSEC_AXISPRM_G12T T_SHORT G1 time constant (Soft acc/dec) (M7Not O O RW 1 to 5000
used)
M_SSEC_AXISPRM_FFGAIN T_SHORT Feed forward gain O O RW 0 to 200
M_SSEC_AXISPRM_G0BACK T_SHORT G0 backlash O O RW -32768 to 32767
M_SSEC_AXISPRM_G1BACK T_SHORT G1 backlash O O RW -32768 to 32767
M_SSEC_AXISPRM_STLIM_MIN T_FLOATBIN/T_LONG Soft limit - (SW OT-) O O RW ±99999.999
M_SSEC_AXISPRM_STLIM_MAX T_FLOATBIN/T_LONG Soft limit - (SW OT+) O O RW ±99999.999
M_SSEC_AXISPRM_TLMLN T_FLOATBIN/T_LONG Negative direction sensor of tool setter O O RW ±99999.999
or TLM standard length
M_SSEC_AXISPRM_TLMLP T_FLOATBIN/T_LONG Positive direction sensor of tool setter O O RW ±99999.999
M_SSEC_AXISPRM_TAPGAINM T_FLOATBIN/T_LONG Axis servo gain O O RW 0.25 to 200.00
M_SSEC_AXISPRM_NOSRV T_CHAR Operation with no servo control O O RW 0,1
M_SSEC_AXISPRM_REVNUM T_CHAR Return steps O O RW 0 to 8
M_SSEC_AXISPRM_OCHKP T_FLOATBIN/T_LONG Spindle orientation completion check O O RW 0 to 99999.999
during second reference position return
M_SSEC_AXISPRM_OUTF T_LONG Maximum speed outside soft limit O O RW 0 to 1000000
range
M_SSEC_AXISPRM_G30SLX T_CHAR Invalidate soft limit (Automatic and O O RW 0,1
manual)
M_SSEC_AXISPRM_OZFMIN T_LONG Set up ATC speed lower limit O O RW 0 to 1000000
M_SSEC_AXISPRM_SYNERR T_LONG Allowable error O O RW ±99999.999
M_SSEC_AXISPRM_MLIMIT1BL T_FLOATBIN/T_LONG Soft limit IB O O RW ±99999.999
M_SSEC_AXISPRM_MLIMIT1BU T_FLOATBIN/T_LONG Soft limit IB+ O O RW ±99999.999
M_SSEC_AXISPRM_MOT1TYPE T_CHAR Soft limit IB type O O RW 0 to 3

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 11 of 206
inventcom

M_SSEC_AXISPRM_FFGAING0 T_SHORT G00 feed forward gain O O RW 0 to 200


M_SSEC_AXISPRM_MRCKAX T_DOUBLE Axis arc radius error correction efficient O O RW -1.000 to 1.000
M_SSEC_AXISPRM_DIVRT T_LONG Rotary axis division count O O RW 0 to 999
M_SSEC_AXISPRM_SAXNO T_CHAR Inclined axis selection O O RW 0 to 2
M_SSEC_AXISPRM_RSLIMIT T_FLOATBIN/T_LONG Restart limit O O RW ±99999.999
M_SSEC_AXISPRM_ZRNDOG T_CHAR Reference position dog O O RW 0x00 to 0xFF
M_SSEC_AXISPRM_HWOTP T_CHAR H/W OT+ O O RW 0x00 to 0xFF
M_SSEC_AXISPRM_HWOTN T_CHAR H/W OT O O RW 0x00 to 0xFF
M_SSEC_AXISPRM_INDEXX T_CHAR Index table indexing axis O O RW 0,1
M_SSEC_AXISPRM_G0INPS T_SHORT G0 in-position width (G0inps) O O RW 0 to 32767
M_SSEC_AXISPRM_G1INPS T_SHORT G1 in-position width (G1inps) O O RW 0 to 32767
M_SSEC_AXISPRM_CHCOMP T_SHORT Chopping compensation amount O O RW 0 to 10
(Parameter value) (chcomp)
M_SSEC_AXISPRM_CHWID T_LONG Chopping compensation amount O O RW 0.000 to 10.000
calculation minimum value (chwid)
M_SSEC_AXISPRM_CHCLSP T_LONG Maximum chopping speed (chclsp) O O RW 0 to 60000
M_SSEC_AXISPRM_A_RSTAX T_CHAR Return order of automatic restart O O RW 0 to 8
position return axis
M_SSEC_AXISPRM_G60_AX T_CHAR Unidirectional positioning operation O O RW 0,1
selection
M_SSEC_AXISPRM_SYNCNT T_CHAR Synchronization super-imposition O O RW 0 to FF
control setting for each axis (syncnt)
M_SSEC_AXISPRM_BSAX_SY T_STR Base axis for synchronization control O O RW 2 letters
(bsax_sy)
M_SSEC_AXISPRM_BSAX_PL T_STR Base axis for super-imposition control O O RW 2 letters
(bsax_pl)
M_SSEC_AXISPRM_PLRAPID T_LONG Rapid traverse rate for super-imposition O O RW 1 to 1000000
control (plrapid)
M_SSEC_AXISPRM_PLCLAMP T_LONG Cutting feed clamp speed for super- O O RW 1 to 1000000
imposition control (plclamp)
M_SSEC_AXISPRM_PLG0TL T_SHORT G0 time constant for super-imposition O O RW 1 to 4000
control - Linear (plG0tL)
M_SSEC_AXISPRM_PLG0T1 T_SHORT G0 time constant for super-imposition O O RW 1 to 5000
control - Primary delay (plG0tl)
M_SSEC_AXISPRM_PLG1TL T_SHORT G1 time constant for super-imposition O O RW 1 to 4000
control - Linear (plG0tL)

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 12 of 206
inventcom

M_SSEC_AXISPRM_PLG1T1 T_SHORT G1 time constant for super-imposition O O RW 1 to 5000


control - Primary delay (plG0tl)
M_SSEC_AXISPRM_CRNCSP T_LONG Minimum corner deceleration speed O O RW 0 to 1000000
M_SSEC_AXISPRM_TLMSUBLN T_FLOATBIN/T_DOUBLE Sub side tool setter - direction sensor O O RW ±99999.999
M_SSEC_AXISPRM_TLMSUBLP T_FLOATBIN/T_DOUBLE Sub side tool setter + direction sensor O O RW ±99999.999
M_SSEC_AXISPRM_LSKPT T_SHORT Skip time constant (Linear) O O RW 1 to 4000
M_SSEC_AXISPRM_SKPT T_SHORT Skip time constant (Primary delay) O O RW 1 to 5000
M_SSEC_AXISPRM_INDEX_UNIT T_SHORT Indexing unit O O RW 0 to 360
M_SSEC_AXISPRM_RAPID_HIMOD T_LONG Rapid traverse rate for high-accuracy O O RW 0 to 10000000
control mode
M_SSEC_AXISPRM_CLAMP_HIMOD T_LONG Cutting feed clamp speed for high- O O RW 0 to 10000000
accuracy control mode
M_SSEC_AXISPRM_BLF_VALID T_UCHAR Quadrant protrusion compensation O O RW 0 to 1
enabled
M_SSEC_AXISPRM_BLF_MI T_LONG Motor inertia O O RW 1 to 32000
M_SSEC_AXISPRM_BLF_VF T_LONG Viscous friction O O RW 1 to 32767
M_SSEC_AXISPRM_BLF_FWDG T_LONG Compensation FF gain O O RW 0 to 1000
M_SSEC_AXISPRM_BLF_ST T_LONG Motor stall torque O O RW 1 to 16000
M_SSEC_AXISPRM_SSCDRSEL T_SHORT Speed monitor Door selection O O RW 0000 to 0003
M_SSEC_AXISPRM_BKVALID T_UCHAR Variable backlash O O RW 0 to 3
disabled/enabled/continuous/Variable
backlash II enabled
M_SSEC_AXISPRM_G0BACKP T_LONG G0 + area compensation amount O O RW -99999999 to 99999999
M_SSEC_AXISPRM_G0BACKC T_LONG G0 centre area compensation amount O O RW -99999999 to 99999999
M_SSEC_AXISPRM_G0BACKM T_LONG G0 - area compensation amount O O RW -99999999 to 99999999
M_SSEC_AXISPRM_G1BACKP T_LONG G1 + area compensation amount O O RW -99999999 to 99999999
M_SSEC_AXISPRM_G1BACKC T_LONG G1 centre area compensation amount O O RW -99999999 to 99999999
M_SSEC_AXISPRM_G1BACKM T_LONG G1 - area compensation amount O O RW -99999999 to 99999999
M_SSEC_AXISPRM_BKFE1 T_LONG G1 compensation amount switch O O RW 0 to 480000
speed 1
M_SSEC_AXISPRM_BKFE2 T_LONG G1 compensation amount switch O O RW 0 to 480000
speed 2
M_SSEC_AXISPRM_BKDIS1 T_FLOATBIN/T_LONG G1 compensation amount switch O O RW -999999.999 to 999999.999
distance 1
M_SSEC_AXISPRM_BKDIS2 T_FLOATBIN/T_LONG G1 compensation amount switch O O RW -999999.999 to 999999.999
distance 2

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 13 of 206
inventcom

M_SSEC_AXISPRM_BKPOS1 T_FLOATBIN/T_LONG G1 compensation amount switch end O O RW -999999.999 to 999999.999


point position 1
M_SSEC_AXISPRM_BKPOS2 T_FLOATBIN/T_LONG G1 compensation amount switch end O O RW -999999.999 to 999999.999
point position 2
M_SSEC_AXISPRM_BKARCK T_SHORT Arc compensation coefficient O O RW 0 to 300
M_SSEC_AXISPRM_BKFRE T_CHAR Reference position speed O O RW 0 to 2
M_SSEC_AXISPRM_BKPRE T_CHAR Reference position end point position O O RW 0 to 2
M_SSEC_AXISPRM_BKDRE T_CHAR Reference position entry direction O O RW 0 to 1
M_SSEC_AXISPRM_BKPOSC T_FLOATBIN/T_LONG Continuous position centre point O O RW -999999.999 to 999999.999
M_SSEC_AXISPRM_OMRFF_OFF T_CHAR omrff_off (OMR-FF disabled) O O RW 0, 1
M_SSEC_AXISPRM_SSCSVOFFLTR T_SHORT Speed monitor Error detection time O O RW 0 to 9999
during servo OFF
M_SSEC_AXISPRM_LCHT T_USHORT Chopping time constant (1st step of O O RW 0 to 4000
soft acc/dec)
M_SSEC_AXISPRM_CH1T T_USHORT Chopping time constant (2nd step of O O RW 0 to 5000
soft acc/dec)
M_SSEC_AXISPRM_POS_BLF_L1 T_FLOATBIN/T_DOUBLE Reference distance for position- O O RW 0 to 999999.999999
dependent increasing-type backlash
compensation 1 (Blf_L1)
M_SSEC_AXISPRM_POS_BLF_L2 T_FLOATBIN/T_DOUBLE Reference distance for position- O O RW 0 to 999999.999999
dependent increasing-type backlash
compensation 2 (Blf_L2)
M_SSEC_AXISPRM_POS_BLF_E1 T_LONG Reference amount of position- O O RW 0 to 99999999
dependent increasing-type backlash
compensation 1 (Blf_E1)
M_SSEC_AXISPRM_POS_BLF_E2 T_LONG Reference amount of position- O O RW 0 to 99999999
dependent increasing-type backlash
compensation 2 (Blf_E2)
M_SSEC_AXISPRM_ROT_LEN T_FLOATBIN 3D machine collision check farthest O O RW 0.000 to 99999.999(mm)
distance from rotary axis center
M_SSEC_AXISPRM_RATEDSPD T_DOUBLE Rated speed O O RW 0 to 1000000
M_SSEC_AXISPRM_ACCRATE T_SHORT Acceleration rate in proportion to the O O RW 0 to 100
maximum acceleration rate
M_SSEC_AXISPRM_G0TRATED T_SHORT G0 time constant up to rated speed O O RW 0 to 4000
(multi-step acceleration/deceleration)
M_SSEC_AXISPRM_HOBFFG T_USHORT Feed forward gain for hobbing O O RW 0 to 200
machining

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 14 of 206
inventcom

M_SSEC_AXISPRM_MM_RTNDIR T_UCHAR Manual measure return direction O O RW 0 to 2


M_SSEC_AXISPRM_LMC1QR T_SHORT Lost motion compensation gain 1 for O O RW -1, 0 to 200
high-speed retract
M_SSEC_AXISPRM_LMC2QR T_SHORT Lost motion compensation gain 2 for O O RW -1, 0 to 200
high-speed retract
M_SSEC_AXISPRM_LMCDQR T_SHORT Lost motion compensation timing for O O RW 0 to 2000
high-speed retract
M_SSEC_AXISPRM_LMCKQR T_SHORT Lost motion compensation 3 spring O O RW 0 to 32767
constant for high-speed retract
M_SSEC_AXISPRM_LMCCQR T_SHORT Lost motion compensation 3 viscous O O RW 0 to 32767
coefficient for high-speed retract
M_SSEC_AXISPRM_SPRADX_RADIUS T_FLOATBIN/T_DOUBLE Special diameter axis (X) radius O O RW 0 to 99999.999
M_SSEC_AXISPRM_SPRADX_CLAMP T_FLOATBIN/T_DOUBLE Clamp speed in controlling special O O RW 1 to 1000000
diameter axis
M_SSEC_AXISPRM_VBL2_VG1 T_DOUBLE Variable backlash compensation II O O RW 1 to 1000000
Compensation data switch speed 1
M_SSEC_AXISPRM_VBL2_VG0 T_DOUBLE Variable backlash compensation II O O RW 1 to 1000000
Compensation data switch speed 2
M_SSEC_AXISPRM_VBL2_P1 T_DOUBLE Variable backlash compensation II O O RW -99999.999 to 99999.999
Stroke point 1
M_SSEC_AXISPRM_VBL2_P2 T_DOUBLE Variable backlash compensation II O O RW -99999.999 to 99999.999
Stroke point 2
M_SSEC_AXISPRM_VBL2_P3 T_DOUBLE Variable backlash compensation II O O RW -99999.999 to 99999.999
Stroke point 3
M_SSEC_AXISPRM_VBL2_BL11 T_LONG Variable backlash compensation II O O RW -99999999 to 99999999
Stroke point 3
M_SSEC_AXISPRM_VBL2_BL12 T_LONG Variable backlash compensation II O O RW -99999999 to 99999999
Switch speed 1, compensation data at
stroke point 2
M_SSEC_AXISPRM_VBL2_BL13 T_LONG Variable backlash compensation II O O RW -99999999 to 99999999
Switch speed 1, compensation data at
stroke point 3
M_SSEC_AXISPRM_VBL2_BL01 T_LONG Variable backlash compensation II O O RW -99999999 to 99999999
Switch speed 2, compensation data at
stroke point 1

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 15 of 206
inventcom

M_SSEC_AXISPRM_VBL2_BL02 T_LONG Variable backlash compensation II O O RW -99999999 to 99999999


Switch speed 2, compensation data at
stroke point 2
M_SSEC_AXISPRM_VBL2_BL03 T_LONG Variable backlash compensation II O O RW -99999999 to 99999999
Switch speed 2, compensation data at
stroke point 3
M_SSEC_AXISPRM_VBL2_FLOAT_TC T_SHORT Variable backlash compensation II Time O O RW 0 to 10000
constant in calculating floating amount
M_SSEC_AXISPRM_VBL2_LM_MUL T_SHORT Variable backlash compensation II O O RW 0 to 10000
Multiplier in calculating lost motion
amount
M_SSEC_AXISPRM_VBL2_VBOUND T_DOUBLE Variable backlash compensation II O O RW 1 to 1000000
Speed boundary value
M_SSEC_AXISPRM_VBL2_COMP_MAG T_SHORT Variable backlash compensation II O O RW 0 to 300
Compensation scale
M_SSEC_AXISPRM_VBL2_COMP_MUL T_SHORT Variable backlash compensation II O O RW 0 to 10000
Multiplier in calculating compensation
amount
M_SSEC_AXISPRM_VBL2_BLE T_LONG Variable backlash compensation II O O RW -99999999 to 99999999
Increasing amount
M_SSEC_AXISPRM_VBL2_BLL T_DOUBLE Variable backlash compensation II O O RW 0 to 99999.999
Increasing travel distance
M_SSEC_AXISPRM_AXISREMOVE T_LONG Axis removal O O RW 0,1
M_SSEC_AXISPRM_INVALIDLIMIT T_LONG Soft limit disabled O O RW 0,1
M_SSEC_AXISPRM_LMITCAN T_CHAR Soft limit temporary cancel O O RW 0,1
M_SSEC_AXISPRM_SW_STLIM_MIN T_FLOATBIN/T_LONG Soft limit O O RW ±99999.999
M_SSEC_AXISPRM_SW_STLIM_MAX T_FLOATBIN/T_LONG Soft limit+ O O RW ±99999.999
M_SSEC_AXISPRM_TCHPOS T_FLOATBIN/T_LONG Tool change O O RW ±99999.999
M_SSEC_AXISPRM_NOG76G87 T_LONG G76/G87 shift ignored O O RW 0: Shift enabled 1: No shift
M_SSEC_AXISPRM_G76G87 T_LONG G76/87 shift (-) O O RW 0: Shift in (+) direction 1: Shift in (-
) direction
M_SSEC_AXISPRM_G60 T_FLOATBIN/T_LONG G60 shift amount O O RW ±99999.999
M_SSEC_AXISPRM_INNERLIMIT T_LONG Soft limit inside O O RW 0,1
M_SSEC_AXISPRM_MIRRORIMG T_LONG Mirror image O O RW 0,1
M_SSEC_AXISPRM_ROT_TYPE T_CHAR Rotary axis type O O RW 0 to 3
M_SSEC_AXISPRM_TLM_LENGTH T_FLOATBIN/T_DOUBLE TLM standard length O O RW ±99999.999
M_SSEC_AXISPRM_G28TYPE T_LONG Type in G28 return O O RW 0,1

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 16 of 206
inventcom

M_SSEC_AXISPRM_CHECK_ST T_FLOATBIN/T_DOUBLE Check start point O O RW ±99999.999


M_SSEC_AXISPRM_NAME_CHAR T_CHAR Axis name char O O RW 0x20 to 0x7A
M_SSEC_AXISPRM_TLML T_FLOATBIN/T_LONG Tool length measurement reference O O RW ±99999.999
length (tlml)
M_SSEC_AXISPRM_TLMH T_FLOATBIN/T_LONG Tool length measurement reference O O RW ±99999.999
surface height (tlmh)
M_SSEC_AXISPRM_BIT_AXBITP T_SHORT Bit parameters of user parameters O O RW 0x0000 to 0xFFFF
(axbitp)
M_SSEC_AXISPRM_BIT_AXCONT T_SHORT Bit parameters of machine parameters O O RW 0x0000 to 0xFFFF
(axcont)
M_SSEC_AXISPRM_G0TRAPID T_SHORT G0 time constant up to rated speed O O R --
(Multi-step acc/dec)
M_SSEC_AXISPRM_SMGST1 T_CHAR Operation parameter group 1 O O RW 1,F
Acceleration/Deceleration type
M_SSEC_AXISPRM_SMGST2 T_CHAR Operation parameter group 2 O O RW 1,F
Acceleration/Deceleration type
M_SSEC_AXISPRM_SMGST3 T_CHAR Operation parameter group 3 O O RW 1,F
Acceleration/Deceleration type
M_SSEC_AXISPRM_SMGST4 T_CHAR Operation parameter group 4 O O RW 1,F
Acceleration/Deceleration type

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 17 of 206
inventcom

Axis parameter for auxiliary axis


Command Data type Description PS AX RW Range
M_SSEC_MPRMAUX_MSR T_SHORT Motor series - O RW 0 to 0xFFFF
M_SSEC_MPRMAUX_RTY T_SHORT Regeneration option type - O RW 0 to 0xFFFF
M_SSEC_MPRMAUX_PC1 T_SHORT Motor side gear ratio (machine rotation - O RW 1 to 32767
ratio)
M_SSEC_MPRMAUX_PC2 T_SHORT Machine side gear ratio (motor rotation - O RW 1 to 32767
ratio)
M_SSEC_MPRMAUX_PIT T_SHORT Feed pitch - O RW 1 to 32767
M_SSEC_MPRMAUX_INP T_SHORT In-position detection width - O RW 1 to 32767
M_SSEC_MPRMAUX_ATU T_SHORT Auto-tuning - O RW 0 to 0xFFFF
M_SSEC_MPRMAUX_PG1 T_SHORT Position loop gain 1 - O RW 4 to 1000
M_SSEC_MPRMAUX_SV009 T_SHORT (sv009) - O RW 0 to 20000
M_SSEC_MPRMAUX_EMG T_SHORT Deceleration control time constant - O RW 0 to 32767
M_SSEC_MPRMAUX_SV011 T_SHORT (sv011) - O RW 0 to 10000
M_SSEC_MPRMAUX_SV015 T_SHORT (sv015) - O RW 1 to 65535
M_SSEC_MPRMAUX_MBR T_SHORT Vertical axis drop prevention - O RW 0 to 1000
M_SSEC_MPRMAUX_NCH T_SHORT Notch filter No. - O RW 0 to 7
M_SSEC_MPRMAUX_KEG T_SHORT (KEG) - O RW 1 to 500
M_SSEC_MPRMAUX_JIT T_SHORT Jitter compensation - O RW 0 to 3
M_SSEC_MPRMAUX_MV1 T_SHORT (MV1) - O RW 0 to 0xFFFF
M_SSEC_MPRMAUX_MV2 T_SHORT (MV2) - O RW 0 to 0xFFFF
M_SSEC_MPRMAUX_PG2 T_SHORT Position loop gain 2 - O RW 1 to 500
M_SSEC_MPRMAUX_VG1 T_SHORT Speed loop gain 1 - O RW 20 to 5000
M_SSEC_MPRMAUX_VG2 T_SHORT Speed loop gain 2 - O RW 20 to 8000
M_SSEC_MPRMAUX_VIS T_SHORT Speed integral compensation - O RW 1 to 1000
M_SSEC_MPRMAUX_VDC T_SHORT Speed differential compensation - O RW 0 to 1000
M_SSEC_MPRMAUX_DG2 T_SHORT Load inertia ratio - O RW 0 to 1000
M_SSEC_MPRMAUX_SV028 T_SHORT (sv028) - O RW 0 to 0xFFFF
M_SSEC_MPRMAUX_MTY T_SHORT Motor type - O RW 0 to 0xFFFF
M_SSEC_MPRMAUX_TMK T_SHORT (TMK) - O RW 0 to 1000
M_SSEC_MPRMAUX_PMS T_SHORT (PMS) - O RW 2 to 8
M_SSEC_MPRMAUX_BAS T_SHORT (BAS) - O RW 1 to 900
M_SSEC_MPRMAUX_MAX T_SHORT (MAX) - O RW 1 to 900

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 18 of 206
inventcom

M_SSEC_MPRMAUX_AMR T_SHORT (AMR) - O RW 0 to 65535


M_SSEC_MPRMAUX_JMK T_SHORT (JMK) - O RW 0 to 65535
M_SSEC_MPRMAUX_KCM T_SHORT (KCM) - O RW 1 to 500
M_SSEC_MPRMAUX_KVI T_SHORT (KVI) - O RW 1 to 500
M_SSEC_MPRMAUX_VGM T_SHORT (VGM) - O RW 1 to 500
M_SSEC_MPRMAUX_MLD T_SHORT (MLD) - O RW 1 to 500
M_SSEC_MPRMAUX_KEC T_SHORT (KEC) - O RW 1 to 500
M_SSEC_MPRMAUX_IQG T_SHORT (IQG) - O RW -9999 to 9999
M_SSEC_MPRMAUX_IDG T_SHORT (IDG) - O RW -9999 to 9999
M_SSEC_MPRMAUX_IQI T_SHORT (IQI) - O RW -9999 to 9999
M_SSEC_MPRMAUX_IDI T_SHORT (IDI) - O RW -9999 to 9999
M_SSEC_MPRMAUX_MD1 T_SHORT D/A output channel 1 data No. - O RW 0 to 0xFFFF
M_SSEC_MPRMAUX_MO1 T_SHORT D/A output channel 1 output offset - O RW -999 to 999
M_SSEC_MPRMAUX_MG1 T_SHORT (MG1) - O RW 0 to 65535
M_SSEC_MPRMAUX_MD2 T_SHORT D/A output channel 2 data No. - O RW 0 to 0xFFFF
M_SSEC_MPRMAUX_MO2 T_SHORT D/A output channel 2 output offset - O RW -999 to 999
M_SSEC_MPRMAUX_MG2 T_SHORT (MG2) - O RW 0 to 65535
M_SSEC_MPRMAUX_STY02 T_CHAR (STY02) - O RW 0 to 0x00FF
M_SSEC_MPRMAUX_STATION T_SHORT Number of indexing stations - O RW 2 to 360
M_SSEC_MPRMAUX_CONT1 T_SHORT Control parameter 1 - O RW 0 to 0xFFFF
M_SSEC_MPRMAUX_CONT2 T_CHAR Control parameter 2 - O RW 0 to 0xFF
M_SSEC_MPRMAUX_EMGCONT T_CHAR Emergency stop control - O RW 0 to 0xFF
M_SSEC_MPRMAUX_TLENG T_LONG Linear axis stroke length - O RW 1 to 99999.999
M_SSEC_MPRMAUX_AXIS_NAM T_STR Axis name - O RW 4 letters
M_SSEC_MPRMAUX_ZRNSPEED T_LONG Reference position return speed - O RW 1 to 100000
M_SSEC_MPRMAUX_ZRNCREEP T_SHORT Reference position return creep speed - O RW 1 to 65535
M_SSEC_MPRMAUX_GRIDMASK T_SHORT Grid mask - O RW 0 to 65535
M_SSEC_MPRMAUX_GRSPC T_CHAR Grid spacing - O RW 0 to 4
M_SSEC_MPRMAUX_ZRNSHIFT T_SHORT Reference position shift amount - O RW 0 to 65535
M_SSEC_MPRMAUX_STOFSET T_FLOATBIN Station offset - O RW -99999.999 to 99999.999
M_SSEC_MPRMAUX_ABSBASE T_FLOATBIN Absolute position zero point - O RW -99999.999 to 99999.999
M_SSEC_MPRMAUX_LIMIT_HIGH T_FLOATBIN Soft limit (+) - O RW -99999.999 to 99999.999
M_SSEC_MPRMAUX_LIMIT_LOW T_FLOATBIN Soft limit (-) - O RW -99999.999 to 99999.999
M_SSEC_MPRMAUX_ABSTYPE T_SHORT Absolute position detection parameter - O RW 0 to 0x00FF
M_SSEC_MPRMAUX_ABSCHECK T_LONG Absolute position power OFF tolerable - O RW 0 to 99999.999
movement value

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 19 of 206
inventcom

M_SSEC_MPRMAUX_BACKLASH T_SHORT Backlash compensation amount - O RW 0 to 9999


M_SSEC_MPRMAUX_YOBI16A T_SHORT (YOB16A) - O RW 0 to 65535
M_SSEC_MPRMAUX_YOBI16B T_SHORT (YOB16B) - O RW 0 to 0xFFFF
M_SSEC_MPRMAUX_YOBI32A T_FLOATBIN (YOBI32A) - O RW -99999999 to 99999999
M_SSEC_MPRMAUX_YOBI32B T_FLOATBIN (YOBI32B) - O RW -99999999 to 99999999
M_SSEC_MPRMAUX_ASPEED1 T_LONG Operation parameter group 1 - O RW 1 to 100000
Automatic operation speed
M_SSEC_MPRMAUX_MSPEED1 T_LONG Operation parameter group 1 Manual - O RW 1 to 100000
operation speed
M_SSEC_MPRMAUX_TIMEL1 T_SHORT Operation parameter group 1 - O RW 1 to 9999
Acceleration/deceleration time constant
1
M_SSEC_MPRMAUX_TIMEL2 T_SHORT Operation parameter group 1 - O RW 1 to 9999
Acceleration/deceleration time constant
2
M_SSEC_MPRMAUX_TL1 T_SHORT Operation parameter group 1 Torque - O RW 0 to 500
limit value
M_SSEC_MPRMAUX_OD1 T_SHORT Operation parameter group 1 Excessive - O RW 0 to 32767
error detection width
M_SSEC_MPRMAUX_JUST1 T_LONG Operation parameter group 1 Set - O RW 0 to 99999.999
position output width
M_SSEC_MPRMAUX_NEAR1 T_LONG Operation parameter group 1 Near set - O RW 0 to 99999.999
position output width
M_SSEC_MPRMAUX_ASPEED2 T_LONG Parameter of operation parameter - O RW 1 to 100000
group 2
M_SSEC_MPRMAUX_MSPEED2 T_LONG Parameter of operation parameter - O RW 1 to 100000
group 2
M_SSEC_MPRMAUX_TIMEL2_1 T_SHORT Parameter of operation parameter - O RW 1 to 9999
group 2
M_SSEC_MPRMAUX_TIMEL2_2 T_SHORT Parameter of operation parameter - O RW 1 to 9999
group 2
M_SSEC_MPRMAUX_TL2 T_SHORT Parameter of operation parameter - O RW 0 to 500
group 2
M_SSEC_MPRMAUX_OD2 T_SHORT Parameter of operation parameter - O RW 0 to 32767
group 2
M_SSEC_MPRMAUX_JUST2 T_LONG Parameter of operation parameter - O RW 0 to 99999.999
group 2

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 20 of 206
inventcom

M_SSEC_MPRMAUX_NEAR2 T_LONG Parameter of operation parameter - O RW 0 to 99999.999


group 2
M_SSEC_MPRMAUX_ASPEED3 T_LONG Parameter of operation parameter - O RW 1 to 100000
group 3
M_SSEC_MPRMAUX_MSPEED3 T_LONG Parameter of operation parameter - O RW 1 to 100000
group 3
M_SSEC_MPRMAUX_TIMEL3_1 T_SHORT Parameter of operation parameter - O RW 1 to 9999
group 3
M_SSEC_MPRMAUX_TIMEL3_2 T_SHORT Parameter of operation parameter - O RW 1 to 9999
group 3
M_SSEC_MPRMAUX_TL3 T_SHORT Parameter of operation parameter - O RW 0 to 500
group 3
M_SSEC_MPRMAUX_OD3 T_SHORT Parameter of operation parameter - O RW 0 to 32767
group 3
M_SSEC_MPRMAUX_JUST3 T_LONG Parameter of operation parameter - O RW 0 to 99999.999
group 3
M_SSEC_MPRMAUX_NEAR3 T_LONG Parameter of operation parameter - O RW 0 to 99999.999
group 3
M_SSEC_MPRMAUX_ASPEED4 T_LONG Parameter of operation parameter - O RW 1 to 100000
group 4
M_SSEC_MPRMAUX_MSPEED4 T_LONG Parameter of operation parameter - O RW 1 to 100000
group 4
M_SSEC_MPRMAUX_TIMEL4_1 T_SHORT Parameter of operation parameter - O RW 1 to 9999
group 4
M_SSEC_MPRMAUX_TIMEL4_2 T_SHORT Parameter of operation parameter - O RW 1 to 9999
group 4
M_SSEC_MPRMAUX_TL4 T_SHORT Parameter of operation parameter - O RW 0 to 500
group 4
M_SSEC_MPRMAUX_OD4 T_SHORT Parameter of operation parameter - O RW 0 to 32767
group 4
M_SSEC_MPRMAUX_JUST4 T_LONG Parameter of operation parameter - O RW 0 to 99999.999
group 4
M_SSEC_MPRMAUX_NEAR4 T_LONG Parameter of operation parameter - O RW 0 to 99999.999
group 4
M_SSEC_MPRMAUX_STOPS1 T_FLOATBIN Station 2 coordinate - O RW -99999.999 to 99999.999
M_SSEC_MPRMAUX_STOPS2 T_FLOATBIN Station 3 coordinate - O RW -99999.999 to 99999.999
M_SSEC_MPRMAUX_STOPS3 T_FLOATBIN Station 4 coordinate - O RW -99999.999 to 99999.999

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 21 of 206
inventcom

M_SSEC_MPRMAUX_STOPS4 T_FLOATBIN Station 5 coordinate - O RW -99999.999 to 99999.999


M_SSEC_MPRMAUX_STOPS5 T_FLOATBIN Station 6 coordinate - O RW -99999.999 to 99999.999
M_SSEC_MPRMAUX_STOPS6 T_FLOATBIN Station 7 coordinate - O RW -99999.999 to 99999.999
M_SSEC_MPRMAUX_STOPS7 T_FLOATBIN Station 8 coordinate - O RW -99999.999 to 99999.999
M_SSEC_MPRMAUX_STOPS8 T_FLOATBIN Station 9 coordinate - O RW -99999.999 to 99999.999
M_SSEC_MPRMAUX_PSWCHECK T_CHAR PSW detection method - O RW 0 to 0xFF
M_SSEC_MPRMAUX_PSW1DOG1 T_FLOATBIN PSW1 area setting 1 - O RW -99999.999 to 99999.999
M_SSEC_MPRMAUX_PSW1DOG2 T_FLOATBIN PSW1 area setting 2 - O RW -99999.999 to 99999.999
M_SSEC_MPRMAUX_PSW2DOG1 T_FLOATBIN PSW2 area setting 1 - O RW -99999.999 to 99999.999
M_SSEC_MPRMAUX_PSW2DOG2 T_FLOATBIN PSW2 area setting 2 - O RW -99999.999 to 99999.999
M_SSEC_MPRMAUX_PSW3DOG1 T_FLOATBIN PSW3 area setting 1 - O RW -99999.999 to 99999.999
M_SSEC_MPRMAUX_PSW3DOG2 T_FLOATBIN PSW3 area setting 2 - O RW -99999.999 to 99999.999
M_SSEC_MPRMAUX_PSW4DOG1 T_FLOATBIN PSW4 area setting 1 - O RW -99999.999 to 99999.999
M_SSEC_MPRMAUX_PSW4DOG2 T_FLOATBIN PSW4 area setting 2 - O RW -99999.999 to 99999.999
M_SSEC_MPRMAUX_PSW5DOG1 T_FLOATBIN PSW5 area setting 1 - O RW -99999.999 to 99999.999
M_SSEC_MPRMAUX_PSW5DOG2 T_FLOATBIN PSW5 area setting 2 - O RW -99999.999 to 99999.999
M_SSEC_MPRMAUX_PSW6DOG1 T_FLOATBIN PSW6 area setting 1 - O RW -99999.999 to 99999.999
M_SSEC_MPRMAUX_PSW6DOG2 T_FLOATBIN PSW6 area setting 2 - O RW -99999.999 to 99999.999
M_SSEC_MPRMAUX_PSW7DOG1 T_FLOATBIN PSW7 area setting 1 - O RW -99999.999 to 99999.999
M_SSEC_MPRMAUX_PSW7DOG2 T_FLOATBIN PSW7 area setting 2 - O RW -99999.999 to 99999.999
M_SSEC_MPRMAUX_PSW8DOG1 T_FLOATBIN PSW8 area setting 1 - O RW -99999.999 to 99999.999
M_SSEC_MPRMAUX_PSW8DOG2 T_FLOATBIN PSW8 area setting 2 - O RW -99999.999 to 99999.999
M_SSEC_MPRMAUX_PUSHT T_LONG Stopper amount - O RW -359999 to 359999
M_SSEC_MPRMAUX_PUSHT1 T_SHORT Stopper standby time - O RW 0 to 9999
M_SSEC_MPRMAUX_PUSHT2 T_SHORT Stopper torque release time - O RW 0 to 9999
M_SSEC_MPRMAUX_PUSHT3 T_SHORT Set position signal output delay time - O RW 0 to 9999

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 22 of 206
inventcom

Axis status
Command Data type Description PS AX RW Range
M_SSEC_AXISSTS_POFF T_CHAR Axis status (Axis removal) O O R
M_SSEC_AXISSTS_SVOF T_CHAR Axis status (Servo OFF) O O R
M_SSEC_AXISSTS_REF1 T_CHAR Axis status (1st ref) O O R
M_SSEC_AXISSTS_REF2 T_CHAR Axis status (2nd ref) O O R
M_SSEC_AXISSTS_REF3 T_CHAR Axis status (3rd ref) O O R
M_SSEC_AXISSTS_REF4 T_CHAR Axis status (4th ref) O O R
M_SSEC_AXISSTS_MR T_CHAR Axis status (Mirror image) O O R
M_SSEC_AXISSTS_RSTAT T_CHAR Axis status (Restart search RP) O O R
M_SSEC_AXISSTS_CT T_CHAR Axis status (Auxiliary axis status CT) O O R 0 to 1 (T_STR : "CT")
M_SSEC_AXISSTS_SVOF_AL T_SHORT Axis status (Servo OFF) all axes O -- R
M_SSEC_AXISSTS_REF1_AL T_SHORT Axis status (1st ref) all axes O -- R
M_SSEC_AXISSTS_REF2_AL T_SHORT Axis status (2nd ref) all axes O -- R
M_SSEC_AXISSTS_REF3_AL T_SHORT Axis status (3rd ref) all axes O -- R
M_SSEC_AXISSTS_REF4_AL T_SHORT Axis status (4the ref) all axes O -- R
M_SSEC_AXISSTS_MR_AL T_LONG Axis status (Mirror image) all axes O -- R
M_SSEC_AXISSTS_RP_AL T_SHORT Axis status (Restart search RP) all axes O -- R
M_SSEC_AXISSTS_PROG_MR_AL T_SHORT Programmed mirror axis (all axes) O -- R
M_SSEC_AXISSTS_AXOFST T_CHAR Information in control axis removal O O R
M_SSEC_AXISSTS_FDT_DIRECT T_CHAR Axis travel direction (FDT direction) O O R 0: No travel 1: Travelling to -
direction 2: Travelling to +
direction

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 23 of 206
inventcom

Background check
Command Data type Description PS AX RW Range
M_SSEC_PRGCHK_OPT_BLKSKIP T_CHAR Optional block skip O -- RW 0,1

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 24 of 206
inventcom

Barrier
Command Data type Description PS AX RW Range
M_SSEC_UPBARI_BARI0X T_FLOATBIN/T_LONG P0 X -- -- RW ±99999.999
M_SSEC_UPBARI_BARI1X T_FLOATBIN/T_LONG P1 X -- -- RW ±99999.999
M_SSEC_UPBARI_BARI1Z T_FLOATBIN/T_LONG P1 Z -- -- RW ±99999.999
M_SSEC_UPBARI_BARI2X T_FLOATBIN/T_LONG P2 X -- -- RW ±99999.999
M_SSEC_UPBARI_BARI2Z T_FLOATBIN/T_LONG P2 Z -- -- RW ±99999.999
M_SSEC_UPBARI_BARI3X T_FLOATBIN/T_LONG P3 X -- -- RW ±99999.999

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 25 of 206
inventcom

Base parameter
Command Data type Description PS AX RW Range
M_SSEC_BASEPRM_SYSON T_CHAR System validation setup O -- RW 0,1
M_SSEC_BASEPRM_PLCSYSON T_CHAR System validation setup (PLC) -- -- RW 0,1
M_SSEC_BASEPRM_AXISMAS T_CHAR Number of axes O -- RW 0 to SYSTEM_AXIS_NO(8)
M_SSEC_BASEPRM_PLCAXISMAS T_CHAR Number of axes (PLC) -- -- RW 0 to PLCMAX(2)
M_SSEC_BASEPRM_IUNIT T_STR Input setup unit O -- RW A,B,C,D,E
M_SSEC_BASEPRM_PLCIUNIT T_STR Input setup unit (PLC) -- -- RW A,B,C,D,E
M_SSEC_BASEPRM_CTRLUNIT T_STR Control unit O -- RW A,B,C,D,E
M_SSEC_BASEPRM_PLCCTRLUNIT T_STR Control unit (PLC) -- -- RW A,B,C,D,E
M_SSEC_BASEPRM_INIPLAN T_CHAR Initial plane selection O -- RW 1 to 3
M_SSEC_BASEPRM_BASE_AXIS_I T_STR Width/surface measure axis name O -- RW Axis address
(Base axis I)
M_SSEC_BASEPRM_BASE_AXIS_J T_STR Width/surface measure axis name O -- RW Axis address
(Base axis J)
M_SSEC_BASEPRM_BASE_AXIS_K T_STR Width/surface measure axis name O -- RW Axis address
(Base axis K)
M_SSEC_BASEPRM_HYOKOH1 T_STR Parallel axis I O -- RW Axis address
M_SSEC_BASEPRM_HTATEH1 T_STR Parallel axis J O -- RW Axis address
M_SSEC_BASEPRM_HTAKAH1 T_STR Parallel axis K O -- RW Axis address
M_SSEC_BASEPRM_CMDTYP T_CHAR Command type â–³ -- RW 1 to 8
M_SSEC_BASEPRM_PLCSEL T_CHAR Ladder selection -- -- RW 0 to 2
M_SSEC_BASEPRM_SP_NUM T_CHAR Number of spindles -- -- RW 0 to 4
M_SSEC_BASEPRM_MINCH T_LONG M_INCH -- -- RW 0,1
M_SSEC_BASEPRM_IINCH T_LONG Initial inch -- -- RW 0,1
M_SSEC_BASEPRM_PCINCH T_CHAR PLC axis inch command -- -- RW 0,1
M_SSEC_BASEPRM_LANG T_CHAR Select language displayed -- -- RW 0 to 3,11 to 20,22
M_SSEC_BASEPRM_AUXNO T_CHAR MR-J2-CT connections -- -- RW 0 to 4
M_SSEC_BASEPRM_NSKNO T_CHAR Mega torque motor connections -- -- RW 0 to 1666
M_SSEC_BASEPRM_MEMPRG T_CHAR Definition of program save area -- -- RW 0 to 7
M_SSEC_BASEPRM_MEMTOL T_LONG Tool compensation memory common -- -- RW 0,1
between part systems
M_SSEC_BASEPRM_MEMVAL T_LONG No. of common variables shared in -- -- RW 0,1
system designation
M_SSEC_BASEPRM_SETUP T_SHORT Activate setup processing -- -- RW 0,1,64

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 26 of 206
inventcom

M_SSEC_BASEPRM_IABSM T_LONG Initial absolute value â–³ -- RW 0,1


M_SSEC_BASEPRM_ISYNC T_LONG Initial synchronization â–³ -- RW 0,1
M_SSEC_BASEPRM_IG00 T_LONG Initial G00 â–³ -- RW 0,1
M_SSEC_BASEPRM_ABSINC T_LONG ABS/INC address â–³ -- RW 0,1
M_SSEC_BASEPRM_RADIUS T_LONG Incremental command of decimeter -- -- RW 0,1
specification axis
M_SSEC_BASEPRM_DECPT2 T_LONG Decimal point type 2 -- -- RW 0,1
M_SSEC_BASEPRM_FLDIGT T_LONG Validate F1 digit -- -- RW 0,1
M_SSEC_BASEPRM_DRILZ T_LONG Specify boring axis -- -- RW 0,1
M_SSEC_BASEPRM_GMACP T_LONG Give priority to G code parameter -- -- RW 0,1
M_SSEC_BASEPRM_GEOMET T_LONG Geometric -- -- RW 0,1
M_SSEC_BASEPRM_RADERMA T_FLOATBIN/T_LONG Arc error -- -- RW 0 to 1.000
M_SSEC_BASEPRM_G00DRN T_LONG G00 dry run â–³ -- RW 0,1
M_SSEC_BASEPRM_G01INTP T_LONG G00 non-interpolation â–³ -- RW 0,1
M_SSEC_BASEPRM_G96G0 T_LONG Constant surface speed control by rapid -- -- RW 0,1
traverse feed command
M_SSEC_BASEPRM_G30SL T_LONG Disable G30 soft limit -- -- RW 0,1
M_SSEC_BASEPRM_CUTRT T_LONG Short cut for rotary axis -- -- RW 0,1
M_SSEC_BASEPRM_LINRT T_LONG Linear rotary axis -- -- RW 0,1
M_SSEC_BASEPRM_MPOINT T_LONG Ignore middle point -- -- RW 0,1
M_SSEC_BASEPRM_TCHGA T_LONG Replace tools for additional axis -- -- RW 0,1
M_SSEC_BASEPRM_WMVFIN T_LONG Type of timing synchronization -- -- RW 0,1
between part systems
M_SSEC_BASEPRM_TLSBK T_CHAR Select life count for single block -- -- RW 0,1
M_SSEC_BASEPRM_T0TFOF T_CHAR TF output -- -- RW 0,1
M_SSEC_BASEPRM_TLTYPE T_CHAR Tool life management type -- -- RW 1,2
M_SSEC_BASEPRM_TLDIGT T_LONG Tool wear compensation number 1-digit -- -- RW 0,1
command
M_SSEC_BASEPRM_TLNO T_LONG Tool length compensation number -- -- RW 0,1
M_SSEC_BASEPRM_TRESET T_LONG Cancel tool compensation amount -- -- RW 0,1
M_SSEC_BASEPRM_TMOVE T_CHAR Tool compensation performance -- -- RW 0 to 2
M_SSEC_BASEPRM_TABSMV T_LONG Tool compensation method -- -- RW 0,1
M_SSEC_BASEPRM_TLM T_LONG Manual tool length measuring system -- -- RW 0,1
M_SSEC_BASEPRM_TLIFE T_LONG Validate life management -- -- RW 0,1
M_SSEC_BASEPRM_TCOM2 T_LONG Tool command method 2 -- -- RW 0,1
M_SSEC_BASEPRM_TSEL2 T_LONG Tool selection method 2 -- -- RW 0,1

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 27 of 206
inventcom

M_SSEC_BASEPRM_TCOUNT T_LONG Life management count -- -- RW 0,1


M_SSEC_BASEPRM_TLLFSC T_CHAR Split life management display screen -- -- RW 0 to 2
M_SSEC_BASEPRM_TLRECTM T_CHAR Life management re-count M code -- -- RW 0 to 99
M_SSEC_BASEPRM_SUBM T_LONG Validate alternate M code â–³ -- RW 0,1
M_SSEC_BASEPRM_M96CODE T_CHAR M96 alternate M code â–³ -- RW 0 to 97
M_SSEC_BASEPRM_M97CODE T_CHAR M97 alternate M code â–³ -- RW 0 to 97
M_SSEC_BASEPRM_STRG T_LONG Validate status trigger system -- -- RW 0,1
M_SSEC_BASEPRM_INT2 T_LONG Validate interrupt method type 2 -- -- RW 0,1
M_SSEC_BASEPRM_MCRINT T_CHAR Macro argument initialization -- -- RW 0 to 2
M_SSEC_BASEPRM_THRWAIT T_CHAR Method for thread cutting -- -- RW 0 to 99
M_SSEC_BASEPRM_G30SLM T_LONG Invalidate soft limit (manual operation) -- -- RW 0,1
M_SSEC_BASEPRM_HSENS T_LONG Handle response switch -- -- RW 0,1
M_SSEC_BASEPRM_MIRRA T_LONG Select how to set up the length of tools -- -- RW 0,1
on cutter tables (opposed tables)
M_SSEC_BASEPRM_TOMIRON T_LONG Select the mirror image of each facing -- -- RW 0,1
turret with T command
M_SSEC_BASEPRM_TOFVAL T_CHAR Change macro variable -- -- RW 0,1
M_SSEC_BASEPRM_EDLKC T_LONG Edit lock C -- -- RW 0,1
M_SSEC_BASEPRM_PGLKC T_CHAR Program display lock -- -- RW 0 to 2
M_SSEC_BASEPRM_ORIGN T_LONG Origin zero inhibition -- -- RW 0,1
M_SSEC_BASEPRM_OFSFIX T_LONG Fix tool wear compensation number -- -- RW 0,1
M_SSEC_BASEPRM_REALF T_LONG Actual feedrate display -- -- RW 0,1
M_SSEC_BASEPRM_PBG90 T_LONG Playback G90 -- -- RW 0,1
M_SSEC_BASEPRM_DPRINT T_LONG DPRINT alignment -- -- RW 0,1
M_SSEC_BASEPRM_RSTVC1 T_LONG Clear variables by resetting -- -- RW 0,1
M_SSEC_BASEPRM_PWRVC1 T_LONG Clear variable by power ON -- -- RW 0,1
M_SSEC_BASEPRM_SETT T_CHAR Display selected tool number -- -- RW 0,1
M_SSEC_BASEPRM_FILDCC T_LONG Feed forward filter -- -- RW --
M_SSEC_BASEPRM_BRIGHT T_CHAR CRT brightness control -- -- RW -3 to 3
M_SSEC_BASEPRM_OFSMEM T_CHAR Select how to set up tool wear -- -- RW 0,1
compensation screen
M_SSEC_BASEPRM_LCDNEG T_CHAR LCD reverse display -- -- RW 0,1
M_SSEC_BASEPRM_UNITNAME T_STR Unit name -- -- RW Alphanumeric characters
M_SSEC_BASEPRM_OPTYPE T_CHAR Operation menu display valid (optype) -- -- RW 0,1
M_SSEC_BASEPRM_CNTSEL T_CHAR Coordinate value screen display -- -- RW 00 to 03, 10 to 13, 20 to 23, 30 to
counter select (Cntsel) 33

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 28 of 206
inventcom

M_SSEC_BASEPRM_PNOSEL T_CHAR Select screen by parameter number -- -- RW 0,1


M_SSEC_BASEPRM_EDTYPE T_CHAR Edit type selection -- -- RW 0 to 4
M_SSEC_BASEPRM_M100 T_LONG M code number 100 -- -- RW 0 to 99999999
M_SSEC_BASEPRM_M200 T_LONG M code number 200 -- -- RW 0 to 99999999
M_SSEC_BASEPRM_M300 T_LONG M code number 300 -- -- RW 0 to 99999999
M_SSEC_BASEPRM_M400 T_LONG M code number 400 -- -- RW 0 to 99999999
M_SSEC_BASEPRM_MDLKOF T_CHAR MDI setup lock -- -- RW 0,1
M_SSEC_BASEPRM_LABS T_LONG Manual ABS parameter -- -- RW 0,1
M_SSEC_BASEPRM_SCLAMP T_LONG Spindle rotation speed clamp function -- -- RW 0,1
M_SSEC_BASEPRM_SMINV T_LONG Minimum spindle rotation speed clamp -- -- RW 0,1
type
M_SSEC_BASEPRM_IG611 T_CHAR Initial high accuracy -- -- RW 0,1
M_SSEC_BASEPRM_CIREFT T_LONG Arc deceleration speed change -- -- RW 0,1
M_SSEC_BASEPRM_FILDCCG0 T_LONG G00 feed forward filter -- -- RW --
M_SSEC_BASEPRM_RSTINT T_LONG Reset initial â–³ -- RW 0,1
M_SSEC_BASEPRM_INIG20 T_CHAR Initial command unit â–³ -- RW 0,1
M_SSEC_BASEPRM_FIXBDC T_CHAR Hole bottom deceleration check -- -- RW 0 to 2
M_SSEC_BASEPRM_PDOOR T_CHAR Door interlock II by each part system -- -- RW 0,1
M_SSEC_BASEPRM_DOORM T_LONG Signal input device 1 for door interlock -- -- RW 0x000 to 0x100
II common between part systems
M_SSEC_BASEPRM_DOORS T_LONG Signal input device 2 for door interlock -- -- RW 0x000 to 0x100
II common between part systems
M_SSEC_BASEPRM_BSCRTYP T_CHAR F0 automatic running -- -- RW Not used (0,1)
M_SSEC_BASEPRM_BSCPGNO T_LONG F0 automatic running program No. -- -- RW Not used (0 to 99999999)
M_SSEC_BASEPRM_FIXPRO T_LONG Fixed cycle editing -- -- RW 0,1
M_SSEC_BASEPRM_E2ROM T_LONG e2rom (Not used) -- -- RW Not used
M_SSEC_BASEPRM_TEST T_LONG Simulation test -- -- RW 0,1
M_SSEC_BASEPRM_SYSNAME T_STR Part system name O -- RW Alphanumeric characters
M_SSEC_BASEPRM_M2NAME T_STR Second miscellaneous code O -- RW A,B,C
M_SSEC_BASEPRM_TAPROV T_SHORT Tap return override O -- RW 1 to 100
M_SSEC_BASEPRM_TAPOVR T_SHORT Tap return override O -- RW 0 to 999
M_SSEC_BASEPRM_DWLSKP T_CHAR G04 skip condition O -- RW 0 to 7
M_SSEC_BASEPRM_SKPSPD0 T_LONG G31 skip speed O -- RW 1 to 1000000
M_SSEC_BASEPRM_SKPCND1 T_CHAR G31.1 skip condition O -- RW 0 to 7
M_SSEC_BASEPRM_SKPSPD1 T_LONG G31.1 skip speed O -- RW 1 to 1000000
M_SSEC_BASEPRM_SKPCND2 T_CHAR G31.2 skip condition O -- RW 0 to 7

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 29 of 206
inventcom

M_SSEC_BASEPRM_SKPSPD2 T_LONG G31.2 skip speed O -- RW 1 to 1000000


M_SSEC_BASEPRM_SKPCND3 T_CHAR G31.3 skip condition O -- RW 0 to 7
M_SSEC_BASEPRM_SKPSPD3 T_LONG G31.3 skip speed O -- RW 1 to 1000000
M_SSEC_BASEPRM_SKPCND4 T_CHAR G31.4 skip condition O -- RW 0 to 7
M_SSEC_BASEPRM_SKPSPD4 T_LONG G31.4 skip speed O -- RW 1 to 1000000
M_SSEC_BASEPRM_G96AXNO T_CHAR Constant surface speed control O -- RW 0 to 8
M_SSEC_BASEPRM_CHNCRP T_LONG Thread cutting speed O -- RW 0 to 60000
M_SSEC_BASEPRM_CLMPM T_LONG M code for clamp O -- RW 0 to 99999999
M_SSEC_BASEPRM_CLMPD T_FLOATBIN/T_LONG Dwelling time after outputting M code O -- RW 0.000 to 99999.999
for unclamp
M_SSEC_BASEPRM_SPDF1 T_LONG F1 digit feedrate F1 O -- RW 1 to 1000000
M_SSEC_BASEPRM_SPDF2 T_LONG F1 digit feedrate F2 O -- RW 1 to 1000000
M_SSEC_BASEPRM_SPDF3 T_LONG F1 digit feedrate F3 O -- RW 1 to 1000000
M_SSEC_BASEPRM_SPDF4 T_LONG F1 digit feedrate F4 O -- RW 1 to 1000000
M_SSEC_BASEPRM_SPDF5 T_LONG F1 digit feedrate F5 O -- RW 1 to 1000000
M_SSEC_BASEPRM_SXCNT T_LONG Validate inclined axis control O -- RW 0,1
M_SSEC_BASEPRM_SANGL T_FLOATBIN/T_LONG Inclination angle O -- RW ±80.000
M_SSEC_BASEPRM_SZRMV T_LONG Compensation at reference position O -- RW 0,1
return
M_SSEC_BASEPRM_INPOS T_CHAR Validate in-position check O -- RW 0,1

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 30 of 206
inventcom

Bit selection
Command Data type Description PS AX RW Range
M_SSEC_MP_SELECT_BIT(x) T_LONG Bit selection (x=0 to 195) -- -- RW 0,1

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 31 of 206
inventcom

Buffer correction
Command Data type Description PS AX RW Range
M_SSEC_BUFEDT_STATUS T_LONG Buffer correction status O -- R
M_SSEC_BUFEDT_PATH T_STR Buffer correction program path O -- R

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 32 of 206
inventcom

CC-Link parameter (Base)


Command Data type Description PS AX RW Range
M_SSEC_CCLK_BASE_EXCHG_NO1 T_CHAR 1st slot Station No. -- -- RW -1 to 64
M_SSEC_CCLK_BASE_TRANS_SP1 T_CHAR 1st slot Transmission rate and mode -- -- RW 0 to 14
M_SSEC_CCLK_BASE_ABNML_LINK1 T_CHAR 1st slot Setting of data link faulty -- -- RW 0,1
station
M_SSEC_CCLK_BASE_PLC_STOP1 T_CHAR 1st slot Setting at PLC STOP -- -- RW 0,1
M_SSEC_CCLK_BASE_OCCUP_BUREAUX1 T_CHAR 1st slot Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BASE_CYCLIC1 T_CHAR 1st slot Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BASE_CONNECT_NUM1 T_CHAR 1st slot Number of connected modules -- -- RW 0 to 64
M_SSEC_CCLK_BASE_RETRY1 T_CHAR 1st slot Number of retries -- -- RW 0 to 7
M_SSEC_CCLK_BASE_AUTO_OPE_MATA1 T_CHAR 1st slot Number of automatic return -- -- RW 0 to 10
modules
M_SSEC_CCLK_BASE_STANDBY_MASTER1 T_CHAR 1st slot Standby master station -- -- RW 0 to 64
M_SSEC_CCLK_BASE_NC_DOWN1 T_CHAR 1st slot Operation at NC down -- -- RW 0,1
M_SSEC_CCLK_BASE_SCAN_MODE1 T_CHAR 1st slot Scan mode -- -- RW 0,1
M_SSEC_CCLK_BASE_DELAY_TIME1 T_CHAR 1st slot Delay time -- -- RW Fixed to 0
M_SSEC_CCLK_BASE_RX_DEV1 T_CHAR 1st slot Remote input (RX) refresh -- -- RW X,M,L,B,D,W,R
device name
M_SSEC_CCLK_BASE_RX_NO1 T_SHORT 1st slot Remote input (RX) refresh -- -- RW Depends on the device name X0
device No. to X5FF M0 to M10239 L0 to
L511 B0 to B1FFF D0 to D2047
W0 to W1FFF R8300 to R9799
R9800 to R9899
M_SSEC_CCLK_BASE_RY_DEV1 T_CHAR 1st slot Remote output (RY) refresh -- -- RW Y,M,L,B,D,W,R
device name
M_SSEC_CCLK_BASE_RY_NO1 T_SHORT 1st slot Remote output (RY) refresh -- -- RW Depends on the device name Y0
device No. to Y5FF Others are the same with
RX
M_SSEC_CCLK_BASE_RWR_DEV1 T_CHAR 1st slot Remote register (RWr) refresh -- -- RW M,L,B,D,W,R
device name
M_SSEC_CCLK_BASE_RWR_NO1 T_SHORT 1st slot Remote register (RWr) refresh -- -- RW Depends on the device name The
device No. same with RX
M_SSEC_CCLK_BASE_RWW_DEV1 T_CHAR 1st slot Remote register (RWw) refresh -- -- RW M,L,B,D,W,R
device name

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 33 of 206
inventcom

M_SSEC_CCLK_BASE_RWW_NO1 T_SHORT 1st slot Remote register (RWw) refresh -- -- RW Depends on the device name The
device No. same with RX
M_SSEC_CCLK_BASE_SB_DEV1 T_CHAR 1st slot Special relay (SB) refresh -- -- RW M,L,B,D,W,R,SB
device name
M_SSEC_CCLK_BASE_SB_NO1 T_SHORT 1st slot Special relay (SB) refresh -- -- RW Depends on the device name SB0
device No. to SB1FF Others are the same
with RX
M_SSEC_CCLK_BASE_SW_DEV1 T_CHAR 1st slot Special relay (SW) refresh -- -- RW M,L,B,D,W,R,SW
device name
M_SSEC_CCLK_BASE_SW_NO1 T_SHORT 1st slot Special relay (SW) refresh -- -- RW Depends on the device name
device No. SW0 to SW1FF Others are the
same with RX
M_SSEC_CCLK_BASE_PRTCL_VER1 T_CHAR 1st slot Protocol version -- -- RW 0,1
M_SSEC_CCLK_BASE_EXCHG_NO2 T_CHAR 2nd slot Station No. -- -- RW -1 to 64
M_SSEC_CCLK_BASE_TRANS_SP2 T_CHAR 2nd slot Transmission rate and mode -- -- RW 0 to 14
M_SSEC_CCLK_BASE_ABNML_LINK2 T_CHAR 2nd slot Setting of data link faulty -- -- RW 0,1
station
M_SSEC_CCLK_BASE_PLC_STOP2 T_CHAR 2nd slot Setting at PLC STOP -- -- RW 0,1
M_SSEC_CCLK_BASE_OCCUP_BUREAUX2 T_CHAR 2nd slot Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BASE_CYCLIC2 T_CHAR 2nd slot Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BASE_CONNECT_NUM2 T_CHAR 2nd slot Number of connected modules -- -- RW 0 to 64
M_SSEC_CCLK_BASE_RETRY2 T_CHAR 2nd slot Number of retries -- -- RW 0 to 7
M_SSEC_CCLK_BASE_AUTO_OPE_MATA2 T_CHAR 2nd slot Number of automatic return -- -- RW 0 to 10
modules
M_SSEC_CCLK_BASE_STANDBY_MASTER2 T_CHAR 2nd slot Standby master station -- -- RW 0 to 64
M_SSEC_CCLK_BASE_NC_DOWN2 T_CHAR 2nd slot Operation at NC down -- -- RW 0,1
M_SSEC_CCLK_BASE_SCAN_MODE2 T_CHAR 2nd slot Scan mode -- -- RW 0,1
M_SSEC_CCLK_BASE_DELAY_TIME2 T_CHAR 2nd slot Delay time -- -- RW Fixed to 0
M_SSEC_CCLK_BASE_RX_DEV2 T_CHAR 2nd slot Remote input (RX) refresh -- -- RW X,M,L,B,D,W,R
device name
M_SSEC_CCLK_BASE_RX_NO2 T_SHORT 2nd slot Remote input (RX) refresh -- -- RW Depends on the device name X0
device No. to X5FF M0 to M10239 L0 to
L511 B0 to B1FFF D0 to D2047
W0 to W1FFF R8300 to R9799
R9800 to R9899
M_SSEC_CCLK_BASE_RY_DEV2 T_CHAR 2nd slot Remote output (RY) refresh -- -- RW Y,M,L,B,D,W,R
device name

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 34 of 206
inventcom

M_SSEC_CCLK_BASE_RY_NO2 T_SHORT 2nd slot Remote output (RY) refresh -- -- RW Depends on the device name Y0
device No. to Y5FF Others are the same with
RX
M_SSEC_CCLK_BASE_RWR_DEV2 T_CHAR 2nd slot Remote register (RWr) refresh -- -- RW M,L,B,D,W,R
device name
M_SSEC_CCLK_BASE_RWR_NO2 T_SHORT 2nd slot Remote register (RWr) refresh -- -- RW Depends on the device name The
device No. same with RX
M_SSEC_CCLK_BASE_RWW_DEV2 T_CHAR 2nd slot Remote register (RWw) -- -- RW M,L,B,D,W,R
refresh device name
M_SSEC_CCLK_BASE_RWW_NO2 T_SHORT 2nd slot Remote register (RWw) -- -- RW Depends on the device name The
refresh device No. same with RX
M_SSEC_CCLK_BASE_SB_DEV2 T_CHAR 2nd slot Special relay (SB) refresh -- -- RW M,L,B,D,W,R,SB
device name
M_SSEC_CCLK_BASE_SB_NO2 T_SHORT 2nd slot Special relay (SB) refresh -- -- RW Depends on the device name SB0
device No. to SB1FF Others are the same
with RX
M_SSEC_CCLK_BASE_SW_DEV2 T_CHAR 2nd slot Special relay (SW) refresh -- -- RW M,L,B,D,W,R,SW
device name
M_SSEC_CCLK_BASE_SW_NO2 T_SHORT 2nd slot Special relay (SW) refresh -- -- RW Depends on the device name
device No. SW0 to SW1FF Others are the
same with RX
M_SSEC_CCLK_BASE_PRTCL_VER2 T_CHAR 2nd slot Protocol version -- -- RW 0,1
M_SSEC_CCLK_BASE_EXCHG_NO3 T_CHAR 3rd slot Station No. -- -- RW -1 to 64
M_SSEC_CCLK_BASE_TRANS_SP3 T_CHAR 3rd slot Transmission rate and mode -- -- RW 0 to 14

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 35 of 206
inventcom

CC-Link parameter (Station information)


Command Data type Description PS AX RW Range
M_SSEC_CCLK_BRAU_CNCT_TYPE1 T_CHAR Station 1 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC1 T_CHAR Station 1 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO1 T_CHAR Station 1 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO1 T_CHAR Station 1 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM1 T_CHAR Station 1 Remote station points -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 1 Reserved station -- -- RW 0 to 2
1
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ1 T_SHORT Station 1 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ1 T_SHORT Station 1 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ1 T_SHORT Station 1 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE2 T_CHAR Station 2 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC2 T_CHAR Station 2 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO2 T_CHAR Station 2 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO2 T_CHAR Station 2 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM2 T_CHAR Station 2 Remote station points -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 2 Reserved station -- -- RW 0 to 2
2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ2 T_SHORT Station 2 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ2 T_SHORT Station 2 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ2 T_SHORT Station 2 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE3 T_CHAR Station 3 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC3 T_CHAR Station 3 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO3 T_CHAR Station 3 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO3 T_CHAR Station 3 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM3 T_CHAR Station 3 Remote station points -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 3 Reserved station -- -- RW 0 to 2
3
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ3 T_SHORT Station 3 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ3 T_SHORT Station 3 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ3 T_SHORT Station 3 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE4 T_CHAR Station 4 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC4 T_CHAR Station 4 Extended cyclic setting -- -- RW 0,1,2,4,8

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 36 of 206
inventcom

M_SSEC_CCLK_BRAU_CNCT_OCCUO4 T_CHAR Station 4 Number of occupied stations -- -- RW 0 to 4


M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO4 T_CHAR Station 4 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM4 T_CHAR Station 4 Remote station points -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 4 Reserved station -- -- RW 0 to 2
4
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ4 T_SHORT Station 4 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ4 T_SHORT Station 4 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ4 T_SHORT Station 4 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE5 T_CHAR Station 5 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC5 T_CHAR Station 5 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO5 T_CHAR Station 5 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO5 T_CHAR Station 5 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM5 T_CHAR Station 5 Remote station points -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 5 Reserved station -- -- RW 0 to 2
5
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ5 T_SHORT Station 5 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ5 T_SHORT Station 5 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ5 T_SHORT Station 5 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE6 T_CHAR Station 6 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC6 T_CHAR Station 6 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO6 T_CHAR Station 6 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO6 T_CHAR Station 6 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM6 T_CHAR Station 6 Remote station points -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 6 Reserved station -- -- RW 0 to 2
6
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ6 T_SHORT Station 6 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ6 T_SHORT Station 6 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ6 T_SHORT Station 6 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE7 T_CHAR Station 7 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC7 T_CHAR Station 7 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO7 T_CHAR Station 7 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO7 T_CHAR Station 7 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM7 T_CHAR Station 7 Remote station points -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 7 Reserved station -- -- RW 0 to 2
7
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ7 T_SHORT Station 7 Send buffer size -- -- RW 0, 64 to 4096

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 37 of 206
inventcom

M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ7 T_SHORT Station 7 Receive buffer size -- -- RW 0, 64 to 4096


M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ7 T_SHORT Station 7 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE8 T_CHAR Station 8 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC8 T_CHAR Station 8 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO8 T_CHAR Station 8 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO8 T_CHAR Station 8 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM8 T_CHAR Station 8 Remote station points -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 8 Reserved station -- -- RW 0 to 2
8
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ8 T_SHORT Station 8 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ8 T_SHORT Station 8 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ8 T_SHORT Station 8 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE9 T_CHAR Station 9 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC9 T_CHAR Station 9 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO9 T_CHAR Station 9 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO9 T_CHAR Station 9 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM9 T_CHAR Station 9 Remote station points -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 9 Reserved station -- -- RW 0 to 2
9
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ9 T_SHORT Station 9 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ9 T_SHORT Station 9 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ9 T_SHORT Station 9 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE10 T_CHAR Station 10 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC10 T_CHAR Station 10 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO10 T_CHAR Station 10 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO10 T_CHAR Station 10 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM1 T_CHAR Station 10 Remote station points -- -- RW 0 to 4
0
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 10 Reserved station -- -- RW 0 to 2
10
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ10 T_SHORT Station 10 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ10 T_SHORT Station 10 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ10 T_SHORT Station 10 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE11 T_CHAR Station 11 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC11 T_CHAR Station 11 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO11 T_CHAR Station 11 Number of occupied stations -- -- RW 0 to 4

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 38 of 206
inventcom

M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO11 T_CHAR Station 11 Station No. -- -- RW 0 to 64


M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM1 T_CHAR Station 11 Remote station points -- -- RW 0 to 4
1
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 11 Reserved station -- -- RW 0 to 2
11
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ11 T_SHORT Station 11 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ11 T_SHORT Station 11 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ11 T_SHORT Station 11 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE12 T_CHAR Station 12 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC12 T_CHAR Station 12 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO12 T_CHAR Station 12 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO12 T_CHAR Station 12 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM1 T_CHAR Station 12 Remote station points -- -- RW 0 to 4
2
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 12 Reserved station -- -- RW 0 to 2
12
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ12 T_SHORT Station 12 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ12 T_SHORT Station 12 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ12 T_SHORT Station 12 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE13 T_CHAR Station 13 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC13 T_CHAR Station 13 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO13 T_CHAR Station 13 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO13 T_CHAR Station 13 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM1 T_CHAR Station 13 Remote station points -- -- RW 0 to 4
3
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 13 Reserved station -- -- RW 0 to 2
13
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ13 T_SHORT Station 13 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ13 T_SHORT Station 13 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ13 T_SHORT Station 13 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE14 T_CHAR Station 14 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC14 T_CHAR Station 14 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO14 T_CHAR Station 14 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO14 T_CHAR Station 14 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM1 T_CHAR Station 14 Remote station points -- -- RW 0 to 4
4

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 39 of 206
inventcom

M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 14 Reserved station -- -- RW 0 to 2


14
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ14 T_SHORT Station 14 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ14 T_SHORT Station 14 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ14 T_SHORT Station 14 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE15 T_CHAR Station 15 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC15 T_CHAR Station 15 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO15 T_CHAR Station 15 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO15 T_CHAR Station 15 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM1 T_CHAR Station 15 Remote station points -- -- RW 0 to 4
5
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 15 Reserved station -- -- RW 0 to 2
15
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ15 T_SHORT Station 15 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ15 T_SHORT Station 15 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ15 T_SHORT Station 15 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE16 T_CHAR Station 16 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC16 T_CHAR Station 16 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO16 T_CHAR Station 16 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO16 T_CHAR Station 16 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM1 T_CHAR Station 16 Remote station points -- -- RW 0 to 4
6
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 16 Reserved station -- -- RW 0 to 2
16
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ16 T_SHORT Station 16 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ16 T_SHORT Station 16 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ16 T_SHORT Station 16 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE17 T_CHAR Station 17 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC17 T_CHAR Station 17 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO17 T_CHAR Station 17 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO17 T_CHAR Station 17 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM1 T_CHAR Station 17 Remote station points -- -- RW 0 to 4
7
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 17 Reserved station -- -- RW 0 to 2
17
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ17 T_SHORT Station 17 Send buffer size -- -- RW 0, 64 to 4096

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 40 of 206
inventcom

M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ17 T_SHORT Station 17 Receive buffer size -- -- RW 0, 64 to 4096


M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ17 T_SHORT Station 17 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE18 T_CHAR Station 18 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC18 T_CHAR Station 18 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO18 T_CHAR Station 18 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO18 T_CHAR Station 18 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM1 T_CHAR Station 18 Remote station points -- -- RW 0 to 4
8
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 18 Reserved station -- -- RW 0 to 2
18
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ18 T_SHORT Station 18 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ18 T_SHORT Station 18 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ18 T_SHORT Station 18 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE19 T_CHAR Station 19 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC19 T_CHAR Station 19 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO19 T_CHAR Station 19 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO19 T_CHAR Station 19 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM1 T_CHAR Station 19 Remote station points -- -- RW 0 to 4
9
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 19 Reserved station -- -- RW 0 to 2
19
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ19 T_SHORT Station 19 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ19 T_SHORT Station 19 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ19 T_SHORT Station 19 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE20 T_CHAR Station 20 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC20 T_CHAR Station 20 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO20 T_CHAR Station 20 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO20 T_CHAR Station 20 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM2 T_CHAR Station 20 Remote station points -- -- RW 0 to 4
0
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 20 Reserved station -- -- RW 0 to 2
20
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ20 T_SHORT Station 20 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ20 T_SHORT Station 20 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ20 T_SHORT Station 20 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE21 T_CHAR Station 21 Station type -- -- RW 0 to 5

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 41 of 206
inventcom

M_SSEC_CCLK_BRAU_CNCT_CYCLIC21 T_CHAR Station 21 Extended cyclic setting -- -- RW 0,1,2,4,8


M_SSEC_CCLK_BRAU_CNCT_OCCUO21 T_CHAR Station 21 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO21 T_CHAR Station 21 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM2 T_CHAR Station 21 Remote station points -- -- RW 0 to 4
1
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 21 Reserved station -- -- RW 0 to 2
21
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ21 T_SHORT Station 21 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ21 T_SHORT Station 21 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ21 T_SHORT Station 21 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE22 T_CHAR Station 22 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC22 T_CHAR Station 22 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO22 T_CHAR Station 22 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO22 T_CHAR Station 22 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM2 T_CHAR Station 22 Remote station points -- -- RW 0 to 4
2
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 22 Reserved station -- -- RW 0 to 2
22
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ22 T_SHORT Station 22 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ22 T_SHORT Station 22 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ22 T_SHORT Station 22 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE23 T_CHAR Station 23 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC23 T_CHAR Station 23 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO23 T_CHAR Station 23 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO23 T_CHAR Station 23 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM2 T_CHAR Station 23 Remote station points -- -- RW 0 to 4
3
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 23 Reserved station -- -- RW 0 to 2
23
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ23 T_SHORT Station 23 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ23 T_SHORT Station 23 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ23 T_SHORT Station 23 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE24 T_CHAR Station 24 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC24 T_CHAR Station 24 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO24 T_CHAR Station 24 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO24 T_CHAR Station 24 Station No. -- -- RW 0 to 64

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 42 of 206
inventcom

M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM2 T_CHAR Station 24 Remote station points -- -- RW 0 to 4


4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 24 Reserved station -- -- RW 0 to 2
24
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ24 T_SHORT Station 24 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ24 T_SHORT Station 24 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ24 T_SHORT Station 24 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE25 T_CHAR Station 25 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC25 T_CHAR Station 25 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO25 T_CHAR Station 25 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO25 T_CHAR Station 25 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM2 T_CHAR Station 25 Remote station points -- -- RW 0 to 4
5
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 25 Reserved station -- -- RW 0 to 2
25
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ25 T_SHORT Station 25 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ25 T_SHORT Station 25 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ25 T_SHORT Station 25 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE26 T_CHAR Station 26 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC26 T_CHAR Station 26 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO26 T_CHAR Station 26 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO26 T_CHAR Station 26 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM2 T_CHAR Station 26 Remote station points -- -- RW 0 to 4
6
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 26 Reserved station -- -- RW 0 to 2
26
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ26 T_SHORT Station 26 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ26 T_SHORT Station 26 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ26 T_SHORT Station 26 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE27 T_CHAR Station 27 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC27 T_CHAR Station 27 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO27 T_CHAR Station 27 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO27 T_CHAR Station 27 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM2 T_CHAR Station 27 Remote station points -- -- RW 0 to 4
7

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 43 of 206
inventcom

M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 27 Reserved station -- -- RW 0 to 2


27
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ27 T_SHORT Station 27 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ27 T_SHORT Station 27 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ27 T_SHORT Station 27 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE28 T_CHAR Station 28 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC28 T_CHAR Station 28 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO28 T_CHAR Station 28 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO28 T_CHAR Station 28 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM2 T_CHAR Station 28 Remote station points -- -- RW 0 to 4
8
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 28 Reserved station -- -- RW 0 to 2
28
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ28 T_SHORT Station 28 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ28 T_SHORT Station 28 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ28 T_SHORT Station 28 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE29 T_CHAR Station 29 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC29 T_CHAR Station 29 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO29 T_CHAR Station 29 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO29 T_CHAR Station 29 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM2 T_CHAR Station 29 Remote station points -- -- RW 0 to 4
9
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 29 Reserved station -- -- RW 0 to 2
29
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ29 T_SHORT Station 29 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ29 T_SHORT Station 29 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ29 T_SHORT Station 29 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE30 T_CHAR Station 30 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC30 T_CHAR Station 30 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO30 T_CHAR Station 30 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO30 T_CHAR Station 30 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM3 T_CHAR Station 30 Remote station points -- -- RW 0 to 4
0
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 30 Reserved station -- -- RW 0 to 2
30
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ30 T_SHORT Station 30 Send buffer size -- -- RW 0, 64 to 4096

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 44 of 206
inventcom

M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ30 T_SHORT Station 30 Receive buffer size -- -- RW 0, 64 to 4096


M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ30 T_SHORT Station 30 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE31 T_CHAR Station 31 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC31 T_CHAR Station 31 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO31 T_CHAR Station 31 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO31 T_CHAR Station 31 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM3 T_CHAR Station 31 Remote station points -- -- RW 0 to 4
1
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 31 Reserved station -- -- RW 0 to 2
31
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ31 T_SHORT Station 31 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ31 T_SHORT Station 31 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ31 T_SHORT Station 31 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE32 T_CHAR Station 32 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC32 T_CHAR Station 32 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO32 T_CHAR Station 32 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO32 T_CHAR Station 32 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM3 T_CHAR Station 32 Remote station points -- -- RW 0 to 4
2
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 32 Reserved station -- -- RW 0 to 2
32
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ32 T_SHORT Station 32 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ32 T_SHORT Station 32 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ32 T_SHORT Station 32 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE33 T_CHAR Station 33 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC33 T_CHAR Station 33 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO33 T_CHAR Station 33 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO33 T_CHAR Station 33 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM3 T_CHAR Station 33 Remote station points -- -- RW 0 to 4
3
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 33 Reserved station -- -- RW 0 to 2
33
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ33 T_SHORT Station 33 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ33 T_SHORT Station 33 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ33 T_SHORT Station 33 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE34 T_CHAR Station 34 Station type -- -- RW 0 to 5

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 45 of 206
inventcom

M_SSEC_CCLK_BRAU_CNCT_CYCLIC34 T_CHAR Station 34 Extended cyclic setting -- -- RW 0,1,2,4,8


M_SSEC_CCLK_BRAU_CNCT_OCCUO34 T_CHAR Station 34 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO34 T_CHAR Station 34 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM3 T_CHAR Station 34 Remote station points -- -- RW 0 to 4
4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 34 Reserved station -- -- RW 0 to 2
34
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ34 T_SHORT Station 34 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ34 T_SHORT Station 34 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ34 T_SHORT Station 34 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE35 T_CHAR Station 35 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC35 T_CHAR Station 35 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO35 T_CHAR Station 35 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO35 T_CHAR Station 35 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM3 T_CHAR Station 35 Remote station points -- -- RW 0 to 4
5
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 35 Reserved station -- -- RW 0 to 2
35
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ35 T_SHORT Station 35 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ35 T_SHORT Station 35 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ35 T_SHORT Station 35 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE36 T_CHAR Station 36 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC36 T_CHAR Station 36 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO36 T_CHAR Station 36 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO36 T_CHAR Station 36 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM3 T_CHAR Station 36 Remote station points -- -- RW 0 to 4
6
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 36 Reserved station -- -- RW 0 to 2
36
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ36 T_SHORT Station 36 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ36 T_SHORT Station 36 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ36 T_SHORT Station 36 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE37 T_CHAR Station 37 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC37 T_CHAR Station 37 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO37 T_CHAR Station 37 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO37 T_CHAR Station 37 Station No. -- -- RW 0 to 64

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 46 of 206
inventcom

M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM3 T_CHAR Station 37 Remote station points -- -- RW 0 to 4


7
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 37 Reserved station -- -- RW 0 to 2
37
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ37 T_SHORT Station 37 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ37 T_SHORT Station 37 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ37 T_SHORT Station 37 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE38 T_CHAR Station 38 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC38 T_CHAR Station 38 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO38 T_CHAR Station 38 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO38 T_CHAR Station 38 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM3 T_CHAR Station 38 Remote station points -- -- RW 0 to 4
8
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 38 Reserved station -- -- RW 0 to 2
38
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ38 T_SHORT Station 38 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ38 T_SHORT Station 38 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ38 T_SHORT Station 38 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE39 T_CHAR Station 39 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC39 T_CHAR Station 39 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO39 T_CHAR Station 39 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO39 T_CHAR Station 39 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM3 T_CHAR Station 39 Remote station points -- -- RW 0 to 4
9
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 39 Reserved station -- -- RW 0 to 2
39
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ39 T_SHORT Station 39 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ39 T_SHORT Station 39 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ39 T_SHORT Station 39 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE40 T_CHAR Station 40 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC40 T_CHAR Station 40 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO40 T_CHAR Station 40 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO40 T_CHAR Station 40 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM4 T_CHAR Station 40 Remote station points -- -- RW 0 to 4
0

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 47 of 206
inventcom

M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 40 Reserved station -- -- RW 0 to 2


40
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ40 T_SHORT Station 40 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ40 T_SHORT Station 40 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ40 T_SHORT Station 40 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE41 T_CHAR Station 41 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC41 T_CHAR Station 41 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO41 T_CHAR Station 41 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO41 T_CHAR Station 41 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM4 T_CHAR Station 41 Remote station points -- -- RW 0 to 4
1
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 41 Reserved station -- -- RW 0 to 2
41
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ41 T_SHORT Station 41 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ41 T_SHORT Station 41 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ41 T_SHORT Station 41 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE42 T_CHAR Station 42 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC42 T_CHAR Station 42 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO42 T_CHAR Station 42 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO42 T_CHAR Station 42 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM4 T_CHAR Station 42 Remote station points -- -- RW 0 to 4
2
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 42 Reserved station -- -- RW 0 to 2
42
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ42 T_SHORT Station 42 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ42 T_SHORT Station 42 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ42 T_SHORT Station 42 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE43 T_CHAR Station 43 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC43 T_CHAR Station 43 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO43 T_CHAR Station 43 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO43 T_CHAR Station 43 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM4 T_CHAR Station 43 Remote station points -- -- RW 0 to 4
3
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 43 Reserved station -- -- RW 0 to 2
43
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ43 T_SHORT Station 43 Send buffer size -- -- RW 0, 64 to 4096

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 48 of 206
inventcom

M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ43 T_SHORT Station 43 Receive buffer size -- -- RW 0, 64 to 4096


M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ43 T_SHORT Station 43 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE44 T_CHAR Station 44 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC44 T_CHAR Station 44 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO44 T_CHAR Station 44 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO44 T_CHAR Station 44 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM4 T_CHAR Station 44 Remote station points -- -- RW 0 to 4
4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 44 Reserved station -- -- RW 0 to 2
44
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ44 T_SHORT Station 44 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ44 T_SHORT Station 44 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ44 T_SHORT Station 44 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE45 T_CHAR Station 45 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC45 T_CHAR Station 45 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO45 T_CHAR Station 45 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO45 T_CHAR Station 45 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM4 T_CHAR Station 45 Remote station points -- -- RW 0 to 4
5
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 45 Reserved station -- -- RW 0 to 2
45
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ45 T_SHORT Station 45 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ45 T_SHORT Station 45 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ45 T_SHORT Station 45 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE46 T_CHAR Station 46 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC46 T_CHAR Station 46 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO46 T_CHAR Station 46 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO46 T_CHAR Station 46 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM4 T_CHAR Station 46 Remote station points -- -- RW 0 to 4
6
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 46 Reserved station -- -- RW 0 to 2
46
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ46 T_SHORT Station 46 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ46 T_SHORT Station 46 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ46 T_SHORT Station 46 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE47 T_CHAR Station 47 Station type -- -- RW 0 to 5

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 49 of 206
inventcom

M_SSEC_CCLK_BRAU_CNCT_CYCLIC47 T_CHAR Station 47 Extended cyclic setting -- -- RW 0,1,2,4,8


M_SSEC_CCLK_BRAU_CNCT_OCCUO47 T_CHAR Station 47 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO47 T_CHAR Station 47 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM4 T_CHAR Station 47 Remote station points -- -- RW 0 to 4
7
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 47 Reserved station -- -- RW 0 to 2
47
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ47 T_SHORT Station 47 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ47 T_SHORT Station 47 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ47 T_SHORT Station 47 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE48 T_CHAR Station 48 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC48 T_CHAR Station 48 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO48 T_CHAR Station 48 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO48 T_CHAR Station 48 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM4 T_CHAR Station 48 Remote station points -- -- RW 0 to 4
8
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 48 Reserved station -- -- RW 0 to 2
48
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ48 T_SHORT Station 48 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ48 T_SHORT Station 48 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ48 T_SHORT Station 48 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE49 T_CHAR Station 49 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC49 T_CHAR Station 49 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO49 T_CHAR Station 49 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO49 T_CHAR Station 49 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM4 T_CHAR Station 49 Remote station points -- -- RW 0 to 4
9
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 49 Reserved station -- -- RW 0 to 2
49
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ49 T_SHORT Station 49 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ49 T_SHORT Station 49 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ49 T_SHORT Station 49 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE50 T_CHAR Station 50 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC50 T_CHAR Station 50 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO50 T_CHAR Station 50 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO50 T_CHAR Station 50 Station No. -- -- RW 0 to 64

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 50 of 206
inventcom

M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM5 T_CHAR Station 50 Remote station points -- -- RW 0 to 4


0
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 50 Reserved station -- -- RW 0 to 2
50
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ50 T_SHORT Station 50 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ50 T_SHORT Station 50 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ50 T_SHORT Station 50 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE51 T_CHAR Station 51 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC51 T_CHAR Station 51 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO51 T_CHAR Station 51 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO51 T_CHAR Station 51 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM5 T_CHAR Station 51 Remote station points -- -- RW 0 to 4
1
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 51 Reserved station -- -- RW 0 to 2
51
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ51 T_SHORT Station 51 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ51 T_SHORT Station 51 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ51 T_SHORT Station 51 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE52 T_CHAR Station 52 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC52 T_CHAR Station 52 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO52 T_CHAR Station 52 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO52 T_CHAR Station 52 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM5 T_CHAR Station 52 Remote station points -- -- RW 0 to 4
2
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 52 Reserved station -- -- RW 0 to 2
52
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ52 T_SHORT Station 52 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ52 T_SHORT Station 52 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ52 T_SHORT Station 52 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE53 T_CHAR Station 53 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC53 T_CHAR Station 53 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO53 T_CHAR Station 53 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO53 T_CHAR Station 53 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM5 T_CHAR Station 53 Remote station points -- -- RW 0 to 4
3

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 51 of 206
inventcom

M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 53 Reserved station -- -- RW 0 to 2


53
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ53 T_SHORT Station 53 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ53 T_SHORT Station 53 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ53 T_SHORT Station 53 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE54 T_CHAR Station 54 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC54 T_CHAR Station 54 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO54 T_CHAR Station 54 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO54 T_CHAR Station 54 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM5 T_CHAR Station 54 Remote station points -- -- RW 0 to 4
4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 54 Reserved station -- -- RW 0 to 2
54
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ54 T_SHORT Station 54 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ54 T_SHORT Station 54 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ54 T_SHORT Station 54 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE55 T_CHAR Station 55 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC55 T_CHAR Station 55 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO55 T_CHAR Station 55 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO55 T_CHAR Station 55 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM5 T_CHAR Station 55 Remote station points -- -- RW 0 to 4
5
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 55 Reserved station -- -- RW 0 to 2
55
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ55 T_SHORT Station 55 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ55 T_SHORT Station 55 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ55 T_SHORT Station 55 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE56 T_CHAR Station 56 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC56 T_CHAR Station 56 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO56 T_CHAR Station 56 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO56 T_CHAR Station 56 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM5 T_CHAR Station 56 Remote station points -- -- RW 0 to 4
6
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 56 Reserved station -- -- RW 0 to 2
56
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ56 T_SHORT Station 56 Send buffer size -- -- RW 0, 64 to 4096

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 52 of 206
inventcom

M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ56 T_SHORT Station 56 Receive buffer size -- -- RW 0, 64 to 4096


M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ56 T_SHORT Station 56 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE57 T_CHAR Station 57 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC57 T_CHAR Station 57 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO57 T_CHAR Station 57 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO57 T_CHAR Station 57 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM5 T_CHAR Station 57 Remote station points -- -- RW 0 to 4
7
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 57 Reserved station -- -- RW 0 to 2
57
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ57 T_SHORT Station 57 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ57 T_SHORT Station 57 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ57 T_SHORT Station 57 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE58 T_CHAR Station 58 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC58 T_CHAR Station 58 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO58 T_CHAR Station 58 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO58 T_CHAR Station 58 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM5 T_CHAR Station 58 Remote station points -- -- RW 0 to 4
8
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 58 Reserved station -- -- RW 0 to 2
58
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ58 T_SHORT Station 58 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ58 T_SHORT Station 58 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ58 T_SHORT Station 58 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE59 T_CHAR Station 59 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC59 T_CHAR Station 59 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO59 T_CHAR Station 59 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO59 T_CHAR Station 59 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM5 T_CHAR Station 59 Remote station points -- -- RW 0 to 4
9
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 59 Reserved station -- -- RW 0 to 2
59
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ59 T_SHORT Station 59 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ59 T_SHORT Station 59 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ59 T_SHORT Station 59 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE60 T_CHAR Station 60 Station type -- -- RW 0 to 5

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 53 of 206
inventcom

M_SSEC_CCLK_BRAU_CNCT_CYCLIC60 T_CHAR Station 60 Extended cyclic setting -- -- RW 0,1,2,4,8


M_SSEC_CCLK_BRAU_CNCT_OCCUO60 T_CHAR Station 60 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO60 T_CHAR Station 60 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM6 T_CHAR Station 60 Remote station points -- -- RW 0 to 4
0
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 60 Reserved station -- -- RW 0 to 2
60
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ60 T_SHORT Station 60 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ60 T_SHORT Station 60 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ60 T_SHORT Station 60 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE61 T_CHAR Station 61 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC61 T_CHAR Station 61 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO61 T_CHAR Station 61 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO61 T_CHAR Station 61 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM6 T_CHAR Station 61 Remote station points -- -- RW 0 to 4
1
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 61 Reserved station -- -- RW 0 to 2
61
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ61 T_SHORT Station 61 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ61 T_SHORT Station 61 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ61 T_SHORT Station 61 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE62 T_CHAR Station 62 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC62 T_CHAR Station 62 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO62 T_CHAR Station 62 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO62 T_CHAR Station 62 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM6 T_CHAR Station 62 Remote station points -- -- RW 0 to 4
2
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 62 Reserved station -- -- RW 0 to 2
62
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ62 T_SHORT Station 62 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ62 T_SHORT Station 62 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ62 T_SHORT Station 62 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE63 T_CHAR Station 63 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC63 T_CHAR Station 63 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO63 T_CHAR Station 63 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO63 T_CHAR Station 63 Station No. -- -- RW 0 to 64

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 54 of 206
inventcom

M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM6 T_CHAR Station 63 Remote station points -- -- RW 0 to 4


3
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 63 Reserved station -- -- RW 0 to 2
63
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ63 T_SHORT Station 63 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ63 T_SHORT Station 63 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ63 T_SHORT Station 63 Automatic update buffer size -- -- RW 0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE64 T_CHAR Station 64 Station type -- -- RW 0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC64 T_CHAR Station 64 Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO64 T_CHAR Station 64 Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO64 T_CHAR Station 64 Station No. -- -- RW 0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM6 T_CHAR Station 64 Remote station points -- -- RW 0 to 4
4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM T_CHAR Station 64 Reserved station -- -- RW 0 to 2
64
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ64 T_SHORT Station 64 Send buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ64 T_SHORT Station 64 Receive buffer size -- -- RW 0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ64 T_SHORT Station 64 Automatic update buffer size -- -- RW 0, 128 to 4096

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 55 of 206
inventcom

CNC information
Command Data type Description PS AX RW Range
M_SSEC_SINFSS_AXIS_NUM_BASE T_CHAR The number of axes in a part system O -- R
(Basic configuration)
M_SSEC_SINFSS_CMVRS_NOS T_SHORT The number of sets of common O -- R
variable (#100-)
M_SSEC_SINFC_NC_AXIS T_CHAR The total number of NC axes (NC) -- -- R
M_SSEC_SINFC_ALL_AXIS T_CHAR The total number of control axes -- -- R
(NC+PLC+SP)
M_SSEC_SINFC_SP_AXIS T_CHAR The number of spindles -- -- R
M_SSEC_SINFC_PLC_AXIS T_CHAR The number of PLC axes -- -- R
M_SSEC_SINFC_AUX_AXIS T_CHAR The number of auxiliary axes -- -- R
M_SSEC_SINFC_FSYS_FORM File system format -- -- R
M_SSEC_SINFC_CMVRC_NOS T_LONG The number of sets of common -- -- R
variables (#500-)
M_SSEC_SINFC_PRSIZE T_SHORT Information of the max. number of -- -- R
machining programs to register
M_SSEC_SINFC_PWSPLY_AXIS T_CHAR The number of power supply axes -- -- R
(SV+SP)
M_SSEC_SINFC_PLCIDX_AXIS T_CHAR The number of PLC indexing axes -- -- R 0-
M_SSEC_SINFC_NCTYPE T_CHAR NC type -- -- R 0 to 1(0: MC, 1: Lathe)
M_SSEC_SINFC_PLCIF_TYPE T_CHAR PLC device allocation type (M6/M7) -- -- R 0 to 1(0: M6 Series, 1: M7)
M_SSEC_SINFC_4PALLET_ON T_CHAR Pallet 4-page registration enabled -- -- R 0 to 1(0: Disabled, 1: Enabled)
M_SSEC_SINFC_CMVRC_N400_ON T_LONG #400 address of common variables -- -- R 0 to 1
enabled
M_SSEC_SINFC_CROSSCOM_ON T_UCHAR #100100 address of common variables -- -- R 0 to 1
common for part systems enabled
M_SSEC_FINF_TOFS_NOS T_SHORT The number of tool compensation sets O -- R
M_SSEC_FINF_WOFS_NOS T_CHAR The number of workpiece offset sets O -- R

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 56 of 206
inventcom

Common variable (By each part system: #100 -)


Command Data type Description PS AX RW Range
M_SSEC_CMVRS_DAT(x) T_DOUBLE 100~199 (x=100~199) O -- RW ±99999999.9999

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 57 of 206
inventcom

Common variable (Common between part systems: #500 -)


Command Data type Description PS AX RW Range
M_SSEC_CMVRC_DAT(x) T_DOUBLE Common variable (common between --/O -- RW ±99999999.9999
part systems #400 to #999) (x=400 to
999)
M_SSEC_CMVRC_CMT(x) T_STR Common variable comment (common --/O -- RW Character string (8 letters)
between part systems #500 to #519)
(x=500 to 519)
M_SSEC_CMVRC_S1_DAT(x) T_DOUBLE Common variable (common between -- -- RW ±99999999.9999
part systems #100100 to #100199)
(x=100 to 199)
M_SSEC_CMVRC_S2_DAT(x) T_DOUBLE Common variable (common between -- -- RW ±99999999.9999
part systems #200100 to #200199)
(x=100 to 199)
M_SSEC_CMVRC_S3_DAT(x) T_DOUBLE Common variable (common between -- -- RW ±99999999.9999
part systems #300100 to #300199)
(x=100 to 199)
M_SSEC_CMVRC_S4_DAT(x) T_DOUBLE Common variable (common between -- -- RW ±99999999.9999
part systems #400100 to #400199)
(x=100 to 199)
M_SSEC_CMVRC_S5_DAT(x) T_DOUBLE Common variable (common between -- -- RW ±99999999.9999
part systems #500100 to #500199)
(x=100 to 199)
M_SSEC_CMVRC_S6_DAT(x) T_DOUBLE Common variable (common between -- -- RW ±99999999.9999
part systems #600100 to #600199)
(x=100 to 199)
M_SSEC_CMVRC_S7_DAT(x) T_DOUBLE Common variable (common between -- -- RW ±99999999.9999
part systems #700100 to #700199)
(x=100 to 199)
M_SSEC_CMVRC_S8_DAT(x) T_DOUBLE Common variable (common between -- -- RW ±99999999.9999
part systems #800100 to #800199)
(x=100 to 199)

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 58 of 206
inventcom

Computer Link parameter


Command Data type Description PS AX RW Range
M_SSEC_UPHLNK_LBAUT T_CHAR Baud rate -- -- RW 0 to 8
M_SSEC_UPHLNK_LSTOPBT T_CHAR Stop bit -- -- RW 1 to 3
M_SSEC_UPHLNK_LPRITYB T_CHAR Parity effective -- -- RW 0,1
M_SSEC_UPHLNK_LPRITYA T_CHAR Even parity -- -- RW 0,1
M_SSEC_UPHLNK_LLENGTH T_CHAR Character length -- -- RW 2 to 3
M_SSEC_UPHLNK_LHAND T_CHAR Hand shake -- -- RW 0 to 3
M_SSEC_UPHLNK_LTIMOUT T_SHORT Time-out set -- -- RW 0 to 999
M_SSEC_UPHLNK_LCDMOD T_CHAR Data code -- -- RW 0,1
M_SSEC_UPHLNK_LPARA1 T_CHAR Link parameter 1 -- -- RW 0x00 to 0xFF
M_SSEC_UPHLNK_LPARA2 T_CHAR Link parameter 2 -- -- RW 0x00 to 0xFF
M_SSEC_UPHLNK_LPARA3 T_CHAR Link parameter 3 -- -- RW 0x00 to 0xFF
M_SSEC_UPHLNK_LPARA4 T_CHAR Link parameter 4 -- -- RW 0x00 to 0xFF
M_SSEC_UPHLNK_LPARA5 T_CHAR Link parameter 5 -- -- RW 0x00 to 0xFF
M_SSEC_UPHLNK_LSTCODE T_CHAR Start code -- -- RW 0,1
M_SSEC_UPHLNK_LCODOUT T_CHAR Control code output -- -- RW 0,1
M_SSEC_UPHLNK_LLNKTMR T_SHORT Control code interval -- -- RW 21 to 255(Not used )
M_SSEC_UPHLNK_LWAITM T_SHORT Wait time -- -- RW 0 to 255(Not used )
M_SSEC_UPHLNK_LPCKLEN T_SHORT Packet length -- -- RW 0 to 3(Not used )
M_SSEC_UPHLNK_BUFFSIZE T_LONG Buffer size -- -- RW 248 to 32768
M_SSEC_UPHLNK_STARTSIZE T_LONG Start size -- -- RW 248 to 32768
M_SSEC_UPHLNK_DC1_OUTSIZE T_LONG DC1 output size -- -- RW 248 to 32768
M_SSEC_UPHLNK_LPOLLTM T_SHORT Polling timer -- -- RW 0 to 999(Not used )
M_SSEC_UPHLNK_LTRNSTM T_CHAR Transfer wait time -- -- RW 0 to 100(Not used )
M_SSEC_UPHLNK_LRTRYTM T_CHAR Retry counter -- -- RW 1 to 100(Not used )

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 59 of 206
inventcom

Coordinate system offset (Extended workpiece coordinate)


Command Data type Description PS AX RW Range
M_SSEC_AWOFS_G54_1P1 T_FLOATBIN/T_LONG G54.1P1 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P2 T_FLOATBIN/T_LONG G54.1P2 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P3 T_FLOATBIN/T_LONG G54.1P3 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P4 T_FLOATBIN/T_LONG G54.1P4 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P5 T_FLOATBIN/T_LONG G54.1P5 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P6 T_FLOATBIN/T_LONG G54.1P6 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P7 T_FLOATBIN/T_LONG G54.1P7 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P8 T_FLOATBIN/T_LONG G54.1P8 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P9 T_FLOATBIN/T_LONG G54.1P9 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P10 T_FLOATBIN/T_LONG G54.1P10 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P11 T_FLOATBIN/T_LONG G54.1P11 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P12 T_FLOATBIN/T_LONG G54.1P12 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P13 T_FLOATBIN/T_LONG G54.1P13 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P14 T_FLOATBIN/T_LONG G54.1P14 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P15 T_FLOATBIN/T_LONG G54.1P15 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P16 T_FLOATBIN/T_LONG G54.1P16 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P17 T_FLOATBIN/T_LONG G54.1P17 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P18 T_FLOATBIN/T_LONG G54.1P18 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P19 T_FLOATBIN/T_LONG G54.1P19 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P20 T_FLOATBIN/T_LONG G54.1P20 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P21 T_FLOATBIN/T_LONG G54.1P21 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P22 T_FLOATBIN/T_LONG G54.1P22 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P23 T_FLOATBIN/T_LONG G54.1P23 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P24 T_FLOATBIN/T_LONG G54.1P24 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P25 T_FLOATBIN/T_LONG G54.1P25 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P26 T_FLOATBIN/T_LONG G54.1P26 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P27 T_FLOATBIN/T_LONG G54.1P27 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P28 T_FLOATBIN/T_LONG G54.1P28 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P29 T_FLOATBIN/T_LONG G54.1P29 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P30 T_FLOATBIN/T_LONG G54.1P30 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P31 T_FLOATBIN/T_LONG G54.1P31 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P32 T_FLOATBIN/T_LONG G54.1P32 O O RW ±99999.999

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 60 of 206
inventcom

M_SSEC_AWOFS_G54_1P33 T_FLOATBIN/T_LONG G54.1P33 O O RW ±99999.999


M_SSEC_AWOFS_G54_1P34 T_FLOATBIN/T_LONG G54.1P34 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P35 T_FLOATBIN/T_LONG G54.1P35 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P36 T_FLOATBIN/T_LONG G54.1P36 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P37 T_FLOATBIN/T_LONG G54.1P37 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P38 T_FLOATBIN/T_LONG G54.1P38 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P39 T_FLOATBIN/T_LONG G54.1P39 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P40 T_FLOATBIN/T_LONG G54.1P40 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P41 T_FLOATBIN/T_LONG G54.1P41 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P42 T_FLOATBIN/T_LONG G54.1P42 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P43 T_FLOATBIN/T_LONG G54.1P43 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P44 T_FLOATBIN/T_LONG G54.1P44 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P45 T_FLOATBIN/T_LONG G54.1P45 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P46 T_FLOATBIN/T_LONG G54.1P46 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P47 T_FLOATBIN/T_LONG G54.1P47 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P48 T_FLOATBIN/T_LONG G54.1P48 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P49 T_FLOATBIN/T_LONG G54.1P49 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P50 T_FLOATBIN/T_LONG G54.1P50 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P51 T_FLOATBIN/T_LONG G54.1P51 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P52 T_FLOATBIN/T_LONG G54.1P52 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P53 T_FLOATBIN/T_LONG G54.1P53 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P54 T_FLOATBIN/T_LONG G54.1P54 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P55 T_FLOATBIN/T_LONG G54.1P55 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P56 T_FLOATBIN/T_LONG G54.1P56 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P57 T_FLOATBIN/T_LONG G54.1P57 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P58 T_FLOATBIN/T_LONG G54.1P58 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P59 T_FLOATBIN/T_LONG G54.1P59 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P60 T_FLOATBIN/T_LONG G54.1P60 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P61 T_FLOATBIN/T_LONG G54.1P61 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P62 T_FLOATBIN/T_LONG G54.1P62 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P63 T_FLOATBIN/T_LONG G54.1P63 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P64 T_FLOATBIN/T_LONG G54.1P64 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P65 T_FLOATBIN/T_LONG G54.1P65 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P66 T_FLOATBIN/T_LONG G54.1P66 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P67 T_FLOATBIN/T_LONG G54.1P67 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P68 T_FLOATBIN/T_LONG G54.1P68 O O RW ±99999.999

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 61 of 206
inventcom

M_SSEC_AWOFS_G54_1P69 T_FLOATBIN/T_LONG G54.1P69 O O RW ±99999.999


M_SSEC_AWOFS_G54_1P70 T_FLOATBIN/T_LONG G54.1P70 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P71 T_FLOATBIN/T_LONG G54.1P71 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P72 T_FLOATBIN/T_LONG G54.1P72 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P73 T_FLOATBIN/T_LONG G54.1P73 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P74 T_FLOATBIN/T_LONG G54.1P74 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P75 T_FLOATBIN/T_LONG G54.1P75 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P76 T_FLOATBIN/T_LONG G54.1P76 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P77 T_FLOATBIN/T_LONG G54.1P77 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P78 T_FLOATBIN/T_LONG G54.1P78 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P79 T_FLOATBIN/T_LONG G54.1P79 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P80 T_FLOATBIN/T_LONG G54.1P80 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P81 T_FLOATBIN/T_LONG G54.1P81 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P82 T_FLOATBIN/T_LONG G54.1P82 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P83 T_FLOATBIN/T_LONG G54.1P83 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P84 T_FLOATBIN/T_LONG G54.1P84 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P85 T_FLOATBIN/T_LONG G54.1P85 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P86 T_FLOATBIN/T_LONG G54.1P86 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P87 T_FLOATBIN/T_LONG G54.1P87 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P88 T_FLOATBIN/T_LONG G54.1P88 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P89 T_FLOATBIN/T_LONG G54.1P89 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P90 T_FLOATBIN/T_LONG G54.1P90 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P91 T_FLOATBIN/T_LONG G54.1P91 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P92 T_FLOATBIN/T_LONG G54.1P92 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P93 T_FLOATBIN/T_LONG G54.1P93 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P94 T_FLOATBIN/T_LONG G54.1P94 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P95 T_FLOATBIN/T_LONG G54.1P95 O O RW ±99999.999
M_SSEC_AWOFS_G54_1P96 T_FLOATBIN/T_LONG G54.1P96 O O RW ±99999.999

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 62 of 206
inventcom

Coordinate system offset (Local coordinate)


Command Data type Description PS AX RW Range
M_SSEC_LOCALOFS_G54 T_FLOATBIN/T_LONG Local coordinate system offset (G54) O O R/W 0
M_SSEC_LOCALOFS_G55 T_FLOATBIN/T_LONG Local coordinate system offset (G55) O O R/W 0
M_SSEC_LOCALOFS_G56 T_FLOATBIN/T_LONG Local coordinate system offset (G56) O O R/W 0
M_SSEC_LOCALOFS_G57 T_FLOATBIN/T_LONG Local coordinate system offset (G57) O O R/W 0
M_SSEC_LOCALOFS_G58 T_FLOATBIN/T_LONG Local coordinate system offset (G58) O O R/W 0
M_SSEC_LOCALOFS_G59 T_FLOATBIN/T_LONG Local coordinate system offset (G59) O O R/W 0

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 63 of 206
inventcom

Coordinate system offset (Other coordinate system)


Command Data type Description PS AX RW Range
M_SSEC_OTHOFS_EXT T_FLOATBIN/T_LONG External workpiece offset (EXT) O O RW ±99999.999
M_SSEC_OTHOFS_G92OFS T_FLOATBIN/T_LONG G92 coordinate system offset O O R

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 64 of 206
inventcom

Coordinate system offset (Workpiece coordinate)


Command Data type Description PS AX RW Range
M_SSEC_WOFS_G54 T_FLOATBIN/T_LONG G54 workpiece coordinate system O O RW ±99999.999
offset
M_SSEC_WOFS_G55 T_FLOATBIN/T_LONG G55 workpiece coordinate system O O RW ±99999.999
offset
M_SSEC_WOFS_G56 T_FLOATBIN/T_LONG G56 workpiece coordinate system O O RW ±99999.999
offset
M_SSEC_WOFS_G57 T_FLOATBIN/T_LONG G57 workpiece coordinate system O O RW ±99999.999
offset
M_SSEC_WOFS_G58 T_FLOATBIN/T_LONG G58 workpiece coordinate system O O RW ±99999.999
offset
M_SSEC_WOFS_G59 T_FLOATBIN/T_LONG G59 workpiece coordinate system O O RW ±99999.999
offset

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 65 of 206
inventcom

Counter
Command Data type Description PS AX RW Range
M_SSEC_CNTR_POS_WRK T_FLOATBIN/T_LONG Workpiece coordinate position counter O O R
M_SSEC_CNTR_POS_MCH T_FLOATBIN/T_LONG Machine position counter O O R
M_SSEC_CNTR_POS_CURRENT T_FLOATBIN/T_LONG Current position counter O O R
M_SSEC_CNTR_POS_RELATV T_FLOATBIN/T_LONG Relative position counter O O R
M_SSEC_CNTR_POS_PROGRAM T_FLOATBIN/T_LONG Program position counter O O R
M_SSEC_CNTR_DISTANCE T_FLOATBIN/T_LONG Remaining command O O R
M_SSEC_CNTR_SKIP T_FLOATBIN/T_LONG Skip coordinate counter (Workpiece O O R
coordinate)
M_SSEC_CNTR_INTER T_FLOATBIN/T_LONG Manual interruption amount 1 (ABS Off) O O R
M_SSEC_CNTR_INTER2 T_FLOATBIN/T_LONG Manual interruption amount 2 (ABS On) O O R
M_SSEC_CNTR_NEXT T_FLOATBIN/T_LONG Next command O O R
M_SSEC_CNTR_POS_RESTART T_FLOATBIN/T_LONG Restart position counter (Workpiece O O R
coordinate)
M_SSEC_CNTR_POS_RE_DIST T_FLOATBIN/T_LONG Remaining restart distance counter O O R
M_SSEC_CNTR_POS_RE_MCH T_FLOATBIN/T_LONG Restart position counter (Machine O O R
coordinate)
M_SSEC_CNTR_POS_PROG2 T_FLOATBIN/T_LONG Program position counter 2 O O R
M_SSEC_CNTR_POS_TLM T_FLOATBIN/T_LONG TLM position counter O O R
M_SSEC_CNTR_TLM_SKIP T_FLOATBIN/T_LONG TLM skip position counter (mxtlms) O O R
M_SSEC_CNTR_TLM T_FLOATBIN/T_LONG TLM position counter (mxtlm) O O R
M_SSEC_CNTR_MXSKPM T_FLOATBIN/T_LONG Skip coordinate counter (Machine O O R
coordinate)
M_SSEC_CNTR_MXSKPR T_FLOATBIN/T_LONG Remaining skip distance counter O O R
M_SSEC_CNTR_LM T_LONG Interpolation combined vector length O -- R
(lm)
M_SSEC_CNTR_POS_CURRENT_B T_FLOATBIN/T_LONG Current position B counter O O R
M_SSEC_CNTR_SKIP_WORK T_FLOATBIN/T_LONG Skip machine value (manual skip O O R -
position)
M_SSEC_CNTR_SKP_COORD_POS T_FLOATBIN Skip coordinate position (skip O O R Special
coordinate counter)
M_SSEC_CNTR_MEAS_POS T_FLOATBIN Measure position O O R Special
M_SSEC_CNTR_POS_TIP_M T_FLOATBIN Tip machine position O O R -
M_SSEC_CNTR_POS_TIP_W T_FLOATBIN Tip workpiece position O O R -

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 66 of 206
inventcom

M_SSEC_CNTR_POS_T_HDL T_FLOATBIN Tool axis movement (ABS OFF) O O R -


M_SSEC_CNTR_POS_MECHA1 T_FLOATBIN 1st mechanical axis angle O - R 0.000 to 720.000(Display with
PLC unit)
M_SSEC_CNTR_POS_MECHA2 T_FLOATBIN 2nd mechanical axis angle O - R 0.000 to 720.000(Display with
PLC unit)
M_SSEC_CNTR_GTR_POS_MCH T_FLOATBIN/T_LONG Machine position counter (for trace) O O R
M_SSEC_CNTR_GTR_POS_WRK T_FLOATBIN/T_LONG Workpiece coordinate counter (for O O R
trace)
M_SSEC_CNTR_POS_MCH_DATA T_FLOATBIN/T_LONG Machine position counter (inclined axis O O R
disabled)
M_SSEC_CNTR_POS_FB T_FLOATBIN/T_LONG Feedback position O O R
M_SSEC_CNTR_TABLE T_FLOATBIN/T_LONG Table coordinate system counter O O R
M_SSEC_CNTR_WORKPOS T_FLOATBIN/T_LONG Workpiece install position coordinate O O R
system counter
M_SSEC_CNTR_SLOPE T_FLOATBIN/T_LONG Inclined surface coordinate system O O R
counter
M_SSEC_CNTR_CNTR_ZERO T_FLOATBIN/T_LONG Counter zero O O W ±99999.999
M_SSEC_CNTR_ORG_ZERO T_FLOATBIN/T_LONG Origin zero O O W Disabled
M_SSEC_CNTR_ORG_CANCEL T_FLOATBIN/T_LONG Origin cancel O O W Disabled

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 67 of 206
inventcom

Cumulative time
Command Data type Description PS AX RW Range
M_SSEC_RTIME_POWER_ON T_LONG/T_STR Power ON time -- -- RW (Special)
M_SSEC_RTIME_AUTO_OP T_LONG/T_STR Automatic operation time -- -- RW (Special)
M_SSEC_RTIME_AUTO_STL T_LONG/T_STR Automatic start up time -- -- RW (Special)
M_SSEC_RTIME_EXT1 T_LONG/T_STR External cumulative time 1 -- -- RW (Special)
M_SSEC_RTIME_EXT2 T_LONG/T_STR External cumulative time 2 -- -- RW (Special)
M_SSEC_RTIME_DATE T_LONG/T_STR Date -- -- RW (Special)
M_SSEC_RTIME_TIME T_LONG/T_STR Time -- -- RW (Special)
M_SSEC_RTIME_CYCLE T_LONG/T_STR Cycle time O -- R (Special)
M_SSEC_RTIME_PROCESS_TIME T_LONG Machining time calculation -- -- RW 0 to 35999999000 (Setting is only
0)

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 68 of 206
inventcom

Ethernet parameter
Command Data type Description PS AX RW Range
M_SSEC_UPETHER_ETHERNET T_CHAR Start of service -- -- RW 0,1
M_SSEC_UPETHER_IPADDR T_STR IP address -- -- RW Alphanumeric characters, symbols
M_SSEC_UPETHER_SUBNET T_STR Subnet mask -- -- RW Alphanumeric characters, symbols
M_SSEC_UPETHER_GATEWAY T_STR Gateway -- -- RW Alphanumeric characters, symbols
M_SSEC_UPETHER_PORTNUMBER T_LONG Port No. -- -- RW 0 to 9999
M_SSEC_UPETHER_BEFORE_HOSTADDR T_STR Ethernet communication parameter -- -- RW Alphanumeric characters, symbols
before conversion (Host address)
M_SSEC_UPETHER_HOSTNUMBER T_LONG Host's port No. -- -- RW 0 to 9999
M_SSEC_UPETHER_LOCAL_IPADDR T_STR Local IP Address - - RW 0.0.0.0 to 255.255.255.255
M_SSEC_UPETHER_LOCAL_SUBNET T_STR Local Subnetmask - - RW 0.0.0.0 to 255.255.255.255
M_SSEC_UPETHER_PC_AUTO_IPADDR T_CHAR IP address automatic setting -- -- RW 0,1
M_SSEC_UPETHER_PC_IPADDR T_STR IP address (PC) -- -- RW Within 15 letters, numerics in dot
notation
M_SSEC_UPETHER_PC_SUBNET T_STR Subnet mask (PC) -- -- RW Within 15 letters, numerics in dot
notation
M_SSEC_UPETHER_PC_GATEWAY T_STR Gateway (PC) -- -- RW Within 15 letters, numerics in dot
notation
M_SSEC_UPETHER_TIMEOUT T_SHORT Time-out -- -- RW 10 to 99
M_SSEC_UPETHER_USE_HOSTNUMBER T_CHAR Host No. to use -- -- RW 1 to 4
M_SSEC_UPETHER_HOST_LOGINNAME(x) T_STR User name (Host A to D) (x=0 to 3) -- -- RW Within 15 letters
M_SSEC_UPETHER_HOST_PWORD(x) T_STR Password (Host A to D) (x=0 to 3) -- -- RW Within 15 letters
M_SSEC_UPETHER_HOST_DIRPATH(x) T_STR Directory (Host A to D) (x=0 to 3) -- -- RW Within 63 letters (M75X: Within
31 letters)
M_SSEC_UPETHER_HOST_IPADDR(x) T_STR Host address (Host A to D) (x=0 to 3) -- -- RW Within 15 letters
M_SSEC_UPETHER_HOST_TYPE(x) T_CHAR Host type (Host 1 to 4) (x=0 to 3) -- -- RW 0 to 2
M_SSEC_UPETHER_HOST_WORD_FILE(x) T_SHORT Host word position: File (Host 1 to 4) -- -- RW 0 to 100
(x=0 to 3)
M_SSEC_UPETHER_HOST_WORD_SIZE(x) T_SHORT Host word position: Size (Host 1 to 4) -- -- RW 0 to 100
(x=0 to 3)
M_SSEC_UPETHER_HOST_WORD_DIR(x) T_SHORT Host word position: <DIR> (Host 1 to -- -- RW 0 to 100
4) (x=0 to 3)
M_SSEC_UPETHER_HOST_WORD_CMT(x) T_SHORT Host word position: Comment (Host 1 -- -- RW 0 to 100
to 4) (x=0 to 3)

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 69 of 206
inventcom

M_SSEC_UPETHER_HOST_WORD_NUM(x) T_SHORT Host word number: Comment (Host 1 -- -- RW 0 to 100


to 4) (x=0 to 3)
M_SSEC_UPETHER_HOST_DISP_TYPE(x) T_CHAR Host character number (Host 1 to 4) -- -- RW 0,1
(x=0 to 3)

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 70 of 206
inventcom

F modal
Command Data type Description PS AX RW Range
M_SSEC_FMDL_FA T_FLOATBIN Program command F modal (FA) O -- R
M_SSEC_FMDL_FM T_FLOATBIN Manual feedrate (FM) O -- R
M_SSEC_FMDL_FS T_FLOATBIN Synchronous feedrate (FS) O -- R
M_SSEC_FMDL_FE T_FLOATBIN Thread cutting lead (FE) O -- R
M_SSEC_FMDL_DWELL T_FLOATBIN Remaining dwell time O -- R
M_SSEC_FMDL_G96S(x) T_LONG Constant surface speed control O -- R
(Surface speed S) (x=1 to 6)

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 71 of 206
inventcom

File information
Command Data type Description PS AX RW Range
M_SSEC_FILEINF_REG_PROG_NOS T_LONG The number of machining programs to -- -- R
register
M_SSEC_FILEINF_USED_PROG_NOS T_LONG The number of remaining machining -- -- R
programs
M_SSEC_FILEINF_CAPA_CHAR_NOS T_LONG Machining program character capacity -- -- R
M_SSEC_FILEINF_FREE_CHAR_NOS T_LONG The number of remaining characters in -- -- R
machining program
M_SSEC_FILEINF_TRANS_SIZE T_LONG Transferred data size of melCopyFile -- -- R

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 72 of 206
inventcom

G modal
Command Data type Description PS AX RW Range
M_SSEC_GMDL_G(x) T_DOUBLE G code (x=Group1 to 21) O -- R
M_SSEC_GMDL_GEO_MC_NO T_SHORT Tool compensation No. of shape O -- R
(diameter) compensation modal
M_SSEC_GMDL_GEO_RADIUS T_LONG Compensation amount of shape O -- R
(diameter) compensation modal
M_SSEC_GMDL_GEO_WEAR T_LONG Wear amount of shape (diameter) O -- R
compensation modal
M_SSEC_GMDL_WEAR_MC_NO T_SHORT Tool compensation No. of diameter O -- R
compensation modal
M_SSEC_GMDL_TPOS T_FLOATBIN/T_LONG Position compensation vector of tool O O R
being used
M_SSEC_GMDL_LENG_MC_NO T_SHORT Tool compensation No. of length O -- R
compensation modal
M_SSEC_GMDL_LENG_AXIS T_STR Axis name of length compensation O O R
modal
M_SSEC_GMDL_LENG_OFFSET T_LONG Compensation amount of length O -- R
compensation modal
M_SSEC_GMDL_LENG_WEAR T_LONG Wear amount of length compensation O -- R
modal
M_SSEC_GMDL_H_COMP_AL T_LONG Information of axis in length O -- R
compensation (All axes)
M_SSEC_GMDL_H_COMP_NO T_LONG Tool compensation No. of length O O R
compensation modal
M_SSEC_GMDL_SCALE_MAG T_FLOATBIN/T_LONG Scaling magnification (G50P_) [Grp11] O -- R
M_SSEC_GMDL_COORD_ROT T_FLOATBIN/T_LONG Coordinate rotation angle (G68R_) O -- R
[Grp16]
M_SSEC_GMDL_H_SPEED_MODE T_LONG High speed machining mode (G5P_) O -- R
M_SSEC_GMDL_GMOV T_CHAR gmov cutting/non-cutting command O -- R
M_SSEC_GMDL_AWOFS_NO T_CHAR Extended workpiece selection O -- R
(G54.1P_)
M_SSEC_GMDL_CUTTING_STS T_SHORT In cutting information O -- R
M_SSEC_GMDL_SCALE_MAG2 T_FLOATBIN Scaling magnification (G50P_)[Grp11] O -- R
(Compatible with Magic)

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 73 of 206
inventcom

M_SSEC_GMDL_COORD_ROT2 T_FLOATBIN Coordinate rotation angle O -- R


(G68R_)[Grp16] (Compatible with
Magic)
M_SSEC_GMDL_3D_DISP_STS T_CHAR 3-dimensional coordinate conversion O -- R
status (For displaying workpiece
coordinate selection G68)
M_SSEC_GMDL_H_SPEED_SPLINE T_LONG Spline interpolation mode O -- R 0: Spline OFF, 1: Spline ON
M_SSEC_GMDL_H_SPEED_SSS T_LONG SSS control O -- R 0: SSS control OFF, 1: SSS control
ON
M_SSEC_GMDL_PREMOD T_CHAR High-accuracy control mode (G08P) O -- R 0: High-accuracy control OFF, 1:
High-accuracy control ON

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 74 of 206
inventcom

Hardware configuration
Command Data type Description PS AX RW Range
M_SSEC_HWCFG_RIO_UNIT(x) T_STR RIO unit 1 to 8 -- -- R
M_SSEC_HWCFG_TERMINAL_RIO(x) T_STR Terminal RIO unit 1 to 4 -- -- R
M_SSEC_HWCFG_MAIN_UNIT T_STR Control unit (NC card) -- -- R
M_SSEC_HWCFG_EXT_UNIT T_STR Extension unit -- -- R
M_SSEC_HWCFG_TERMINAL T_STR Terminal display (For M7) -- -- R
M_SSEC_HWCFG_OPT_CARD T_STR Extension bus for optional card -- -- R
(OPTION CARD) (For M7)
M_SSEC_HWCFG_ATT_CARD T_STR External interface for CPUCARD -- -- R
(Magic68)
M_SSEC_HWCFG_OPE_CARD T_STR External interface for CPUCARD (For -- -- R
M7)
M_SSEC_HWCFG_RIO_NOS T_STR The number of RIO units (For M7) -- -- R
M_SSEC_HWCFG_RIO_ALL(x) T_STR RIO unit (For M7) (x=1 to 32) -- -- R
M_SSEC_HWCFG_CNC_UNITS(x) T_STR Control unit 1 to 4(M7)(x=1 to 4) -- -- R
M_SSEC_HWCFG_EXT_UNITS(x) T_STR Extension unit 1 to 4(M7)(x=1 to 4) -- -- R
M_SSEC_HWCFG_CNC_UNITS_VER(x) T_STR Control unit hardware version 1 to -- -- R
4(x=1 to 4)
M_SSEC_HWCFG_RAS_BATTERY_VOLT T_SHORT Battery voltage -- -- R 0: Normal 1: Battery low 2:
Encoder error 3: No voltage
M_SSEC_HWCFG_RAS_BATTERY_STS T_CHAR Battery voltage status -- -- R 0: Normal 1: Warning 2: Alarm

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 75 of 206
inventcom

Input/Output parameter
Command Data type Description PS AX RW Range
M_SSEC_UPIO_SINPORT T_CHAR Data input <Port No.> -- -- RW 1 to 2
M_SSEC_UPIO_SINDEV T_CHAR Data input <Device No.> -- -- RW 0 to 4
M_SSEC_UPIO_SOTPORT T_CHAR Data output <Port No.> -- -- RW 1 to 2
M_SSEC_UPIO_SOTDEV T_CHAR Data output <Device No.> -- -- RW 0 to 4
M_SSEC_UPIO_SNCPORT T_CHAR Tape operation <Port No.> -- -- RW 1 to 2
M_SSEC_UPIO_SNCDEV T_CHAR Tape operation <Device No.> -- -- RW 0 to 4
M_SSEC_UPIO_MCRPORT T_CHAR Macro print <Port No.> -- -- RW 1 to 2
M_SSEC_UPIO_MCRDEV T_CHAR Macro print <Device No.> -- -- RW 0 to 4
M_SSEC_UPIO_PLCPORT T_CHAR PLC input/output <Port No.> -- -- RW 1 to 2
M_SSEC_UPIO_PLCDEV T_CHAR PLC input/output <Device No.> -- -- RW 0 to 4
M_SSEC_UPIO_RPGPORT T_CHAR Remote program input <Port No.> -- -- RW 1 to 2
M_SSEC_UPIO_RPGDEV T_CHAR Remote program input <Device No.> -- -- RW 0 to 4
M_SSEC_UPIO_EXTPORT T_CHAR External unit <Port No.> -- -- RW 1 to 2
M_SSEC_UPIO_EXTDEV T_CHAR External unit <Device No.> -- -- RW 0 to 4
M_SSEC_UPIO_SIOTP1_DEVNAME T_STR Device 1 Device name -- -- RW 3 letters (Alphanumeric
characters, symbols)
M_SSEC_UPIO_SIOTP1_BAUDRT T_CHAR Device 1 Baud rate -- -- RW 0 to 7
M_SSEC_UPIO_SIOTP1_STOPBT T_CHAR Device 1 Stop bit -- -- RW 1 to 3
M_SSEC_UPIO_SIOTP1_PARITYB T_CHAR Device 1 Parity enabled -- -- RW 0,1
M_SSEC_UPIO_SIOTP1_PARITYA T_CHAR Device 1 Even parity -- -- RW 0,1
M_SSEC_UPIO_SIOTP1_LENCH T_CHAR Device 1 Character length -- -- RW 0 to 3
M_SSEC_UPIO_SIOTP1_TERMTP T_CHAR Device 1 Terminator type -- -- RW 0 to 3
M_SSEC_UPIO_SIOTP1_HANDTP T_CHAR Device 1 Hand shake -- -- RW 1 to 4
M_SSEC_UPIO_SIOTP1_DCPARI T_CHAR Device 1 DC code parity -- -- RW 0,1
M_SSEC_UPIO_SIOTP1_FEEDFLG T_CHAR Device 1 DC2/DC4 output -- -- RW 0 to 3
M_SSEC_UPIO_SIOTP1_CROUT T_CHAR Device 1 CR output -- -- RW 0,1
M_SSEC_UPIO_SIOTP1_EIAOUT T_LONG Device 1 EIA output -- -- RW 0,1
M_SSEC_UPIO_SIOTP1_FEEDCHR T_SHORT Device 1 Feed character -- -- RW 0 to 999
M_SSEC_UPIO_SIOTP1_PARITYV T_LONG Device 1 Parity V -- -- RW 0,1
M_SSEC_UPIO_SIOTP1_TOUT T_SHORT Device 1 Time-out -- -- RW 0 to 30
M_SSEC_UPIO_SIOTP1_DROFF T_CHAR Device 1 DR OFF -- -- RW 0,1
M_SSEC_UPIO_SIOTP1_DATASCII T_LONG Device 1 Data ASCII -- -- RW 0,1

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 76 of 206
inventcom

M_SSEC_UPIO_SIOTP1_INTYPE T_CHAR Device 1 Input type -- -- RW 0,1


M_SSEC_UPIO_SIOTP1_KAKKOL T_CHAR Device 1 EIA code [ -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP1_KAKKOR T_CHAR Device 1 EIA code ] -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP1_SYAAPU T_CHAR Device 1 EIA code # -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP1_ASTA T_CHAR Device 1 EIA code * -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP1_EQUAL T_CHAR Device 1 EIA code = -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP1_KORONN T_CHAR Device 1 EIA code : -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP1_SYSCD T_CHAR Device 1 EIA code $ -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP1_DOUKICD T_CHAR Device 1 EIA code ! -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP2_DEVNAME T_STR Device 2 Device name -- -- RW 3 letters (Alphanumeric
characters, symbols)
M_SSEC_UPIO_SIOTP2_BAUDRT T_CHAR Device 2 Baud rate -- -- RW 0 to 7
M_SSEC_UPIO_SIOTP2_STOPBT T_CHAR Device 2 Stop bit -- -- RW 1 to 3
M_SSEC_UPIO_SIOTP2_PARITYB T_CHAR Device 2 Parity enabled -- -- RW 0,1
M_SSEC_UPIO_SIOTP2_PARITYA T_CHAR Device 2 Even parity -- -- RW 0,1
M_SSEC_UPIO_SIOTP2_LENCH T_CHAR Device 2 Character length -- -- RW 0 to 3
M_SSEC_UPIO_SIOTP2_TERMTP T_CHAR Device 2 Terminator type -- -- RW 0 to 3
M_SSEC_UPIO_SIOTP2_HANDTP T_CHAR Device 2 Hand shake -- -- RW 1 to 4
M_SSEC_UPIO_SIOTP2_FEEDFLG T_CHAR Device 2 DC2/DC4 output -- -- RW 0 to 3
M_SSEC_UPIO_SIOTP2_CROUT T_CHAR Device 2 CR output -- -- RW 0,1
M_SSEC_UPIO_SIOTP2_EIAOUT T_LONG Device 2 EIA output -- -- RW 0,1
M_SSEC_UPIO_SIOTP2_FEEDCHR T_SHORT Device 2 Feed character -- -- RW 0 to 999
M_SSEC_UPIO_SIOTP2_PARITYV T_LONG Device 2 Parity V -- -- RW 0,1
M_SSEC_UPIO_SIOTP2_TOUT T_SHORT Device 2 Time-out -- -- RW 0 to 30
M_SSEC_UPIO_SIOTP2_DROFF T_CHAR Device 2 DR OFF -- -- RW 0,1
M_SSEC_UPIO_SIOTP2_DATASCII T_LONG Device 2 Data ASCII -- -- RW 0,1
M_SSEC_UPIO_SIOTP2_INTYPE T_CHAR Device 2 Input type -- -- RW 0,1
M_SSEC_UPIO_SIOTP2_KAKKOL T_CHAR Device 2 EIA code [ -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP2_KAKKOR T_CHAR Device 2 EIA code ] -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP2_SYAAPU T_CHAR Device 2 EIA code # -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP2_ASTA T_CHAR Device 2 EIA code * -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP2_EQUAL T_CHAR Device 2 EIA code = -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP2_KORONN T_CHAR Device 2 EIA code : -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP2_SYSCD T_CHAR Device 2 EIA code $ -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP2_DOUKICD T_CHAR Device 2 EIA code ! -- -- RW 0x00 to 0xFF

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 77 of 206
inventcom

M_SSEC_UPIO_SIOTP3_DEVNAME T_STR Device 3 Device name -- -- RW 3 letters (Alphanumeric


characters, symbols)
M_SSEC_UPIO_SIOTP3_BAUDRT T_CHAR Device 3 Baud rate -- -- RW 0 to 7
M_SSEC_UPIO_SIOTP3_STOPBT T_CHAR Device 3 Stop bit -- -- RW 1 to 3
M_SSEC_UPIO_SIOTP3_PARITYB T_CHAR Device 3 Parity enabled -- -- RW 0,1
M_SSEC_UPIO_SIOTP3_PARITYA T_CHAR Device 3 Even parity -- -- RW 0,1
M_SSEC_UPIO_SIOTP3_LENCH T_CHAR Device 3 Character length -- -- RW 0 to 3
M_SSEC_UPIO_SIOTP3_TERMTP T_CHAR Device 3 Terminator type -- -- RW 0 to 3
M_SSEC_UPIO_SIOTP3_HANDTP T_CHAR Device 3 Hand shake -- -- RW 1 to 4
M_SSEC_UPIO_SIOTP3_DCPARI T_CHAR Device 3 DC code parity -- -- RW 0,1
M_SSEC_UPIO_SIOTP3_FEEDFLG T_CHAR Device 3 DC3/DC4 output -- -- RW 0 to 3
M_SSEC_UPIO_SIOTP3_CROUT T_CHAR Device 3 CR output -- -- RW 0,1
M_SSEC_UPIO_SIOTP3_EIAOUT T_LONG Device 3 EIA output -- -- RW 0,1
M_SSEC_UPIO_SIOTP3_FEEDCHR T_SHORT Device 3 Feed character -- -- RW 0 to 999
M_SSEC_UPIO_SIOTP3_PARITYV T_LONG Device 3 Parity V -- -- RW 0,1
M_SSEC_UPIO_SIOTP3_TOUT T_SHORT Device 3 Time-out -- -- RW 0 to 30
M_SSEC_UPIO_SIOTP3_DROFF T_CHAR Device 3 DR OFF -- -- RW 0,1
M_SSEC_UPIO_SIOTP3_DATASCII T_LONG Device 3 Data ASCII -- -- RW 0,1
M_SSEC_UPIO_SIOTP3_INTYPE T_CHAR Device 3 Input type -- -- RW 0,1
M_SSEC_UPIO_SIOTP3_KAKKOL T_CHAR Device 3 EIA code [ -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP3_KAKKOR T_CHAR Device 3 EIA code ] -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP3_SYAAPU T_CHAR Device 3 EIA code # -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP3_ASTA T_CHAR Device 3 EIA code * -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP3_EQUAL T_CHAR Device 3 EIA code = -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP3_KORONN T_CHAR Device 3 EIA code : -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP3_SYSCD T_CHAR Device 3 EIA code $ -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP3_DOUKICD T_CHAR Device 3 EIA code ! -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP4_DEVNAME T_STR Device 4 Device name -- -- RW 3 letters (Alphanumeric
characters, symbols)
M_SSEC_UPIO_SIOTP4_BAUDRT T_CHAR Device 4 Baud rate -- -- RW 0 to 7
M_SSEC_UPIO_SIOTP4_STOPBT T_CHAR Device 4 Stop bit -- -- RW 1 to 3
M_SSEC_UPIO_SIOTP4_PARITYB T_CHAR Device 4 Parity enabled -- -- RW 0,1
M_SSEC_UPIO_SIOTP4_PARITYA T_CHAR Device 4 Even parity -- -- RW 0,1
M_SSEC_UPIO_SIOTP4_LENCH T_CHAR Device 4 Character length -- -- RW 0 to 3
M_SSEC_UPIO_SIOTP4_TERMTP T_CHAR Device 4 Terminator type -- -- RW 0 to 3
M_SSEC_UPIO_SIOTP4_HANDTP T_CHAR Device 4 Hand shake -- -- RW 1 to 4

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 78 of 206
inventcom

M_SSEC_UPIO_SIOTP4_DCPARI T_CHAR Device 4 DC code parity -- -- RW 0,1


M_SSEC_UPIO_SIOTP4_FEEDFLG T_CHAR Device 4 DC4/DC4 output -- -- RW 0 to 3
M_SSEC_UPIO_SIOTP4_CROUT T_CHAR Device 4 CR output -- -- RW 0,1
M_SSEC_UPIO_SIOTP4_EIAOUT T_LONG Device 4 EIA output -- -- RW 0,1
M_SSEC_UPIO_SIOTP4_FEEDCHR T_SHORT Device 4 Feed character -- -- RW 0 to 999
M_SSEC_UPIO_SIOTP4_PARITYV T_LONG Device 4 Parity V -- -- RW 0,1
M_SSEC_UPIO_SIOTP4_TOUT T_SHORT Device 4 Time-out -- -- RW 0 to 30
M_SSEC_UPIO_SIOTP4_DROFF T_CHAR Device 4 DR OFF -- -- RW 0,1
M_SSEC_UPIO_SIOTP4_DATASCII T_LONG Device 4 Data ASCII -- -- RW 0,1
M_SSEC_UPIO_SIOTP4_INTYPE T_CHAR Device 4 Input type -- -- RW 0,1
M_SSEC_UPIO_SIOTP4_KAKKOL T_CHAR Device 4 EIA code [ -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP4_KAKKOR T_CHAR Device 4 EIA code ] -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP4_SYAAPU T_CHAR Device 4 EIA code # -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP4_ASTA T_CHAR Device 4 EIA code * -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP4_EQUAL T_CHAR Device 4 EIA code = -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP4_KORONN T_CHAR Device 4 EIA code : -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP4_SYSCD T_CHAR Device 4 EIA code $ -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP4_DOUKICD T_CHAR Device 4 EIA code ! -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP5_DEVNAME T_STR Device 5 Device name -- -- RW 3 letters (Alphanumeric
characters, symbols)
M_SSEC_UPIO_SIOTP5_BAUDRT T_CHAR Device 5 Baud rate -- -- RW 0 to 7
M_SSEC_UPIO_SIOTP5_STOPBT T_CHAR Device 5 Stop bit -- -- RW 1 to 3
M_SSEC_UPIO_SIOTP5_PARITYB T_CHAR Device 5 Parity enabled -- -- RW 0,1
M_SSEC_UPIO_SIOTP5_PARITYA T_CHAR Device 5 Even parity -- -- RW 0,1
M_SSEC_UPIO_SIOTP5_LENCH T_CHAR Device 5 Character length -- -- RW 0 to 3
M_SSEC_UPIO_SIOTP5_TERMTP T_CHAR Device 5 Terminator type -- -- RW 0 to 3
M_SSEC_UPIO_SIOTP5_HANDTP T_CHAR Device 5 Hand shake -- -- RW 1 to 4
M_SSEC_UPIO_SIOTP5_DCPARI T_CHAR Device 5 DC code parity -- -- RW 0,1
M_SSEC_UPIO_SIOTP5_FEEDFLG T_CHAR Device 5 DC5/DC5 output -- -- RW 0 to 3
M_SSEC_UPIO_SIOTP5_CROUT T_CHAR Device 5 CR output -- -- RW 0,1
M_SSEC_UPIO_SIOTP5_EIAOUT T_LONG Device 5 EIA output -- -- RW 0,1
M_SSEC_UPIO_SIOTP5_FEEDCHR T_SHORT Device 5 Feed character -- -- RW 0 to 999
M_SSEC_UPIO_SIOTP5_PARITYV T_LONG Device 5 Parity V -- -- RW 0,1
M_SSEC_UPIO_SIOTP5_TOUT T_SHORT Device 5 Time-out -- -- RW 0 to 30
M_SSEC_UPIO_SIOTP5_DROFF T_CHAR Device 5 DR OFF -- -- RW 0,1
M_SSEC_UPIO_SIOTP5_DATASCII T_LONG Device 5 Data ASCII -- -- RW 0,1

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 79 of 206
inventcom

M_SSEC_UPIO_SIOTP5_INTYPE T_CHAR Device 5 Input type -- -- RW 0,1


M_SSEC_UPIO_SIOTP5_KAKKOL T_CHAR Device 5 EIA code [ -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP5_KAKKOR T_CHAR Device 5 EIA code ] -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP5_SYAAPU T_CHAR Device 5 EIA code # -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP5_ASTA T_CHAR Device 5 EIA code * -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP5_EQUAL T_CHAR Device 5 EIA code = -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP5_KORONN T_CHAR Device 5 EIA code : -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP5_SYSCD T_CHAR Device 5 EIA code $ -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_SIOTP5_DOUKICD T_CHAR Device 5 EIA code ! -- -- RW 0x00 to 0xFF
M_SSEC_UPIO_HANDYTERMINAL_PORT T_CHAR Handy terminal <Port No.> -- -- RW 1 to 2
M_SSEC_UPIO_HANDYTERMINAL_DEV T_CHAR Handy terminal <Device No.> -- -- RW 0 to 4
M_SSEC_UPIO_DATA_IO_PORT T_CHAR Data I/O port -- -- RW 0 to 2
M_SSEC_UPIO_TAPE_MODE_PORT T_CHAR Tape mode port -- -- RW 0 to 2
M_SSEC_UPIO_SIOTP1_OUTBUF T_CHAR Device 1 Output buffer -- -- RW 0 to 5
M_SSEC_UPIO_SIOTP2_OUTBUF T_CHAR Device 2 Output buffer -- -- RW 0 to 5
M_SSEC_UPIO_SIOTP3_OUTBUF T_CHAR Device 3 Output buffer -- -- RW 0 to 5
M_SSEC_UPIO_SIOTP4_OUTBUF T_CHAR Device 4 Output buffer -- -- RW 0 to 5
M_SSEC_UPIO_SIOTP5_OUTBUF T_CHAR Device 5 Output buffer -- -- RW 0 to 5

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 80 of 206
inventcom

Key history
Command Data type Description PS AX RW Range
M_SSEC_KEYHIST_SAMPSTS T_CHAR Collection status of sampling -- -- R 0,1,2
M_SSEC_KEYHIST_HISTSTS T_CHAR Collection status of history -- -- R 0,1
M_SSEC_KEYHIST_SPEC_SYS T_CHAR Specification-Part system -- -- RW 0x00 to 0x0F
M_SSEC_KEYHIST_SPEC_SP T_CHAR Specification-Spindle -- -- RW 0x00 to 0x0F
M_SSEC_KEYHIST_SPEC_SV T_SHORT Specification-Servo -- -- RW 0x0000 to 0xFFFF
M_SSEC_KEYHIST_DATA_HW T_LONG Data-Hardware configuration -- -- RW 0,1
M_SSEC_KEYHIST_DATA_SW T_LONG Data-Software configuration -- -- RW 0,1
M_SSEC_KEYHIST_DATA_KEYHIST T_LONG Data-Key history -- -- RW 0,1
M_SSEC_KEYHIST_DATA_ALARMHIST T_LONG Data-Alarm history -- -- RW 0,1
M_SSEC_KEYHIST_DATA_PLCIOHIST T_LONG Data-PLC input/output signal history -- -- RW 0,1
M_SSEC_KEYHIST_DATA_ACINHIST T_LONG Data-AC input power supply error -- -- RW 0,1
history
M_SSEC_KEYHIST_DATA_SPDATA1 T_LONG Data-Spindle data 1 -- -- RW 0,1
M_SSEC_KEYHIST_DATA_SPDATA2 T_LONG Data-Spindle data 2 -- -- RW 0,1
M_SSEC_KEYHIST_DATA_SVDATA1 T_LONG Data-Servo data 1 -- -- RW 0,1
M_SSEC_KEYHIST_DATA_SVDATA2 T_LONG Data-Servo data 2 -- -- RW 0,1
M_SSEC_KEYHIST_DATA_MODALINFO T_LONG Data-Modal information -- -- RW 0,1
M_SSEC_KEYHIST_DATA_PRGDATA T_LONG Data-Program data -- -- RW 0,1
M_SSEC_KEYHIST_DATA_COORDDATA T_LONG Data-Coordination data -- -- RW 0,1
M_SSEC_KEYHIST_SAMP_TRIGGER T_LONG Request of sampling start/stop -- -- W 0,1
(Manual)
M_SSEC_KEYHIST_HIST_TRIGGER T_LONG Request of history start/stop (Manual) -- -- W 0,1
M_SSEC_KEYHIST_PWON T_LONG Request of data collection start/stop at -- -- W 0,1
power ON
M_SSEC_KEYHIST_SAMP_CLR T_LONG Sampling data clear -- -- W 1
M_SSEC_KEYHIST_HIST_CLR T_LONG History data clear -- -- W 1
M_SSEC_KEYHIST_ALMHIST_CLR T_LONG Alarm history data clear - -- W 1

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 81 of 206
inventcom

Ladder interface (Common)


Command Data type Description PS AX RW Range
M_SSEC_LDCM_LOADM_NAME(x) T_STR Load meter name (x=1,2) O - R
M_SSEC_LDCM_LOADM_SCALE1(x) T_STR Load meter graduation comment 1st O - R
line (x=1,2)
M_SSEC_LDCM_LOADM_UNIT(x) T_STR Load meter unit comment (x=1,2) O - R
M_SSEC_LDCM_LOADM_SCALE2(x) T_STR Load meter graduation comment 2nd O - R
line (x=1,2)
M_SSEC_LDCM_SPWAIT_CMT(x) T_STR Spindle standby tool comment (x=0 to - - R
4)
M_SSEC_LDCM_PLCSW_MSG(x) T_STR PLC switch message (x=1 to 32) - - R

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 82 of 206
inventcom

Life management data


Command Data type Description PS AX RW Range
M_SSEC_TLIFEDAT_TOOL_NO(x) T_LONG Tool No. (x=1 to 1000) O -- RW 1 to 99999999
M_SSEC_TLIFEDAT_STATUS(x) T_CHAR Status (x=1 to 1000) O -- RW 0x00 to 0xFF (Do not exceed 4 by
the lowest 3 Bits)
M_SSEC_TLIFEDAT_MTHD(x) T_CHAR Method (x=1 to 1000) O -- RW 0x000 to 0xFFF (Special)
M_SSEC_TLIFEDAT_L_COMPEN(x) T_FLOATBIN/T_LONG Length compensation (x=1 to 1000) O -- RW (Special)
M_SSEC_TLIFEDAT_R_COMPEN(x) T_FLOATBIN/T_LONG Diameter compensation (x=1 to 1000) O -- RW (Special)
M_SSEC_TLIFEDAT_USED(x) T_LONG Used (time, the number of times, wear O -- RW (Special)
amount) (x=1 to 1000)
M_SSEC_TLIFEDAT_LIFE(x) T_LONG Life (time, the number of times, wear O -- RW (Special)
amount) (x=1 to 1000)
M_SSEC_TLIFEDAT_AUXIL(x) T_SHORT Auxiliary (x=1 to 1000) O -- RW 0 to 65535
M_SSEC_TLIFEDAT_GROUP_NO(x) T_LONG Group No. (x=1 to 1000) O -- RW 1 to 99999999
M_SSEC_TLIFEDAT_DEL_GROUP T_LONG Delete group designating group No. O -- W 1 to 99999999
M_SSEC_TLIFEDAT_ADD_TOOL T_STR Add tool O -- W 1 to 99999999, 1 to 99999999,
0x00 to FF (Do not exceed 4 by
the lowest 3 Bits)
M_SSEC_TLIFEDAT_GROUPID T_LONG Group ID of the designated group No. O -- RW Setting: 1 to 99999999 (Group
No.) Getting: 0 to 799 (Group ID)
M_SSEC_TLIFEDAT_GROUPNO(x) T_LONG Group No. of the designated group ID O -- R 1 to 99999999
(x=1 to 1000)
M_SSEC_TLIFEDAT_TOP_REC_ID(x) T_LONG Head record ID of the designated group O -- R 0 to the number of managed tools
ID (x=1 to 1000) -1
M_SSEC_TLIFEDAT_TLNOS_GROUPID(x) T_LONG The number of tools registered in the O -- R 1 to the number of managed tools
designated group ID (x=1 to 1000)
M_SSEC_TLIFEDAT_CHG_GROUP(x) T_LONG Change group No. of the designated O -- W 1 to 99999999
group ID (x=1 to 1000)
M_SSEC_TLIFEDAT_DEL_TOOL(x) T_LONG Delete tool of the designated record O -- W (Special)
(x=1 to 1000)
M_SSEC_TLIFEDAT_TOOLDATA(x) T_STR Tool data of the designated record (x=1 O -- R (Special) Use a comma as
to 1000) delimeter of records
M_SSEC_TLIFEDAT_GNO_DSP(x) T_BUFF Get group No. of the designated group O -- R (Special)
ID (60 items) (x=1 to 1000)

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 83 of 206
inventcom

M_SSEC_TLIFEDAT_GRP_LIFE_INFO(x) T_BUFF Get life expiration information of the O -- R (Special)


designated group ID (60 items) (x=1 to
1000)
M_SSEC_TLIFEDAT_L1TOOL_USE_TIME(x) T_LONG Total hours to use tool (Tool No. x=1 to O -- RW 0 to 35999900 (Unit: msec)
200)
M_SSEC_TLIFEDAT_L1TOOL_LIFE_TIME(x) T_LONG Setting hours of tool life (Tool No. x=1 O -- RW 0 to 35999900 (Unit: msec)
to 200)
M_SSEC_TLIFEDAT_L1TOOL_USE_NUM(x) T_SHORT Total number of times to use tool (Tool O -- RW 0 to 9999
No. x=1 to 200)
M_SSEC_TLIFEDAT_L1TOOL_LIFE_NUM(x) T_SHORT Setting number of times to use tool O -- RW 0 to 9999
(Tool No. x=1 to 200)
M_SSEC_TLIFEDAT_L1STATUS_A(x) T_CHAR Status A (Tool No. x=1 to 200) O -- RW 0 to 2
M_SSEC_TLIFEDAT_L1STATUS_B(x) T_CHAR Status B (Tool No. x=1 to 200) O -- RW 0 to 2
M_SSEC_TLIFEDAT_L1DEL_DAT(x) T_CHAR Clear data of the designated tool (Tool O -- W 0
No. x=1 to 200)
M_SSEC_TLIFEDAT_L2DEL_GROUP T_LONG Delete group designating group No. O -- W 1 to 9999
M_SSEC_TLIFEDAT_L2ADD_TOOL T_STR Add tool O -- W 1 to 9999,1 to 999999,0 to 80
M_SSEC_TLIFEDAT_L2GROUP_ID(x) T_LONG Group ID of the designated group O -- R 0 to 199
No.(x=1 to 9999: Group No. 1 to 9999)
M_SSEC_TLIFEDAT_L2GROUP_NO(x) T_LONG Group No. of the designated group ID O -- R 1 to 9999
(x=1 to 200: Group ID 0 to 199)
M_SSEC_TLIFEDAT_L2TOP_REC_ID(x) T_LONG Head record ID of the designated group O -- R 0 to 199
ID (x=1 to 200: Group ID 0 to 199)
M_SSEC_TLIFEDAT_L2GROUP_TOOL_NUM(x) T_LONG The number of tools registered in the O -- R 1 to 200
designated group ID (x=1 to 200: Group
ID 0 to 199)
M_SSEC_TLIFEDAT_L2CHG_GROUP(x) T_LONG Change group No. of the designated O -- W 1 to 9999
group ID (x=1 to 200: Group ID 0 to
199)
M_SSEC_TLIFEDAT_L2DEL_TOOL(x) T_CHAR Delete tool of the designated record O -- W (Special)
(x=1 to 200: Tool ID 0 to 199)
M_SSEC_TLIFEDAT_L2TOOL_NO(x) T_LONG Tool No. of the designated tool ID (x=1 O -- RW 1 to 999999
to 200: Tool ID 0 to 199)
M_SSEC_TLIFEDAT_L2COMP_NO(x) T_CHAR Tool compensation No. of the O -- RW 0 to 80
designated tool ID (x=1 to 200: Tool ID
0 to 199)

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 84 of 206
inventcom

M_SSEC_TLIFEDAT_L2USE_DATA(x) T_LONG Use of the designated tool ID (MIN) O -- RW 0 to 999999


(x=1 to 200: Tool ID 0 to 199)
M_SSEC_TLIFEDAT_L2STATUS(x) T_CHAR ST of the designated tool ID (x=1 to O -- RW 0 to 3
200: Tool ID 0 to 199)
M_SSEC_TLIFEDAT_L2SYSTEM(x) T_CHAR Method of the designated tool ID (x=1 O -- RW 0 to 1
to 200: Group ID 0 to 199)
M_SSEC_TLIFEDAT_L2LIFE(x) T_LONG Life of the designated tool ID (x=1 to O -- RW 0 to 999999
200: Group ID 0 to 199)
M_SSEC_TLIFEDAT_L2GROUP_LIFE_CHK(x) T_CHAR Check whether the designated group O -- R 0 to 1
ID has life-expired tool (x=1 to 200:
Group ID 0 to 199)
M_SSEC_TLIFEDAT_L2USE_GROUP_NO T_LONG Group No. of the tool being used O -- R 1 to 9999
M_SSEC_TLIFEDAT_L2USE_TOOL_NO T_LONG Tool No. of the tool being used O -- R 1 to 999999
M_SSEC_TLIFEDAT_L2USE_COMP_NO T_CHAR Compensation No. of the tool being O -- R 0 to 80
used
M_SSEC_TLIFEDAT_L2USE_SYSTEM T_CHAR Method of the tool being used O -- R 0 to 1
M_SSEC_TLIFEDAT_L2USE_USEDATA T_LONG Use of the tool being used (MIN) O -- R 0 to 999999
M_SSEC_TLIFEDAT_L2USE_SUM T_LONG Sum of the tool being used O -- R 0 to 999999
M_SSEC_TLIFEDAT_L2USE_LIFE T_LONG Life of the tool being used O -- R 0 to 999999
M_SSEC_TLIFEDAT_L2USE_STATUS T_CHAR ST of the tool being used O -- R 0 to 3

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 85 of 206
inventcom

Life management information


Command Data type Description PS AX RW Range
M_SSEC_TLIFINF_TOOL_NOS T_LONG The number of tools in life O -- R
management
M_SSEC_TLIFINF_GROUP_NOS T_LONG The number of registration groups in O -- R
life management
M_SSEC_TLIFINF_CHG_FLAG T_CHAR Data change flag in life management O -- R
M_SSEC_TLIFINF_TOOL_MAX T_LONG The maximum registration number of O -- R
tools in life management
M_SSEC_TLIFINF_L1TOOL_MAX T_LONG The maximum registration number of O -- R 0 to 200
tools in life management (L sys TYPE I)
M_SSEC_TLIFINF_L2TOOL_NOS T_SHORT The number of tools in life O -- R 1 to 200
management (L sys TYPE II)
M_SSEC_TLIFINF_L2ALL_GROUP_NOS T_SHORT The number of registration groups in O -- R 1 to 200
life management (L sys TYPE II)
M_SSEC_TLIFINF_L2TOOL_MAX T_SHORT The maximum registration number of O -- R 0 to 200
tools in life management (L sys TYPE II)
M_SSEC_TLIFINF_FORMAT T_CHAR Life management data format - - W 1

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 86 of 206
inventcom

Local variable
Command Data type Description PS AX RW Range
M_SSEC_LOCVR_LV0_DAT(x) T_DOUBLE Local variable (Level0) (x=1 to 33) O -- R
M_SSEC_LOCVR_LV1_DAT(x) T_DOUBLE Local variable (Level1) (x=1 to 33) O -- R
M_SSEC_LOCVR_LV2_DAT(x) T_DOUBLE Local variable (Level2) (x=1 to 33) O -- R
M_SSEC_LOCVR_LV3_DAT(x) T_DOUBLE Local variable (Level3) (x=1 to 33) O -- R
M_SSEC_LOCVR_LV4_DAT(x) T_DOUBLE Local variable (Level4) (x=1 to 33) O -- R
M_SSEC_LOCVR_EMPTY_VAL T_DOUBLE Local variable empty variable O -- R

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 87 of 206
inventcom

Machine error compensation parameter


Command Data type Description PS AX RW Range
M_SSEC_MPMER_PINC T_LONG Machine error compensation increment -- -- RW 0,1
method
M_SSEC_MPMER_CMPASC(x) T_STR 1st to 28th axis base axis (1 to 28) -- -- RW Axis address of #1013
M_SSEC_MPMER_DRCASC(x) T_STR 1st to 28th axis compensation axis (1 to -- -- RW Axis address of #1013
28)
M_SSEC_MPMER_RDIVNOMS(x) T_SHORT 1st to 28th axis division point number -- -- RW 4101 to 5124
at reference position (1 to 28)
M_SSEC_MPMER_MDIVNOMS(x) T_SHORT 1st to 28th axis division point number -- -- RW 4101 to 5124
at the most negative position (1 to 28)
M_SSEC_MPMER_PDIVNOMS(x) T_SHORT 1st to 28th axis division point number -- -- RW 4101 to 5124
at the most positive position (1 to 28)
M_SSEC_MPMER_SCL(x) T_SHORT 1st to 28th axis compensation scale (1 -- -- RW 0 to 99
to 28)
M_SSEC_MPMER_SPCDIV(x) T_LONG 1st to 28th axis division interval (1 to -- -- RW 1 to 9999999
28)
M_SSEC_MPMER_PCMP(x) T_CHAR Pitch error compensation amount (0 to -- -- RW -128 to 128
1023)
M_SSEC_MPMER_TWOPC(x) T_CHAR 1st to 28th axis 2-way pitch error -- -- RW 0,1
compensation (1 to 28)
M_SSEC_MPMER_REFRV(x) T_SHORT 1st to 28th axis reference position -- -- RW -32768 to 32767
compensation amount (1 to 28)

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 88 of 206
inventcom

Macro list
Command Data type Description PS AX RW Range
M_SSEC_MPLMAC_M01_TMCODE T_SHORT M[01] code -- -- RW 0 to 9999
M_SSEC_MPLMAC_M01_TMMACROT T_CHAR M[01] type -- -- RW 0 to 3
M_SSEC_MPLMAC_M01_TMMACRO T_STR M[01] program No. -- -- RW 0 to 999999999
M_SSEC_MPLMAC_M02_TMCODE T_SHORT M[02] code -- -- RW 0 to 9999
M_SSEC_MPLMAC_M02_TMMACROT T_CHAR M[02] type -- -- RW 0 to 3
M_SSEC_MPLMAC_M02_TMMACRO T_STR M[02] program No. -- -- RW 0 to 999999999
M_SSEC_MPLMAC_M03_TMCODE T_SHORT M[03] code -- -- RW 0 to 9999
M_SSEC_MPLMAC_M03_TMMACROT T_CHAR M[03] type -- -- RW 0 to 3
M_SSEC_MPLMAC_M03_TMMACRO T_STR M[03] program No. -- -- RW 0 to 999999999
M_SSEC_MPLMAC_M04_TMCODE T_SHORT M[04] code -- -- RW 0 to 9999
M_SSEC_MPLMAC_M04_TMMACROT T_CHAR M[04] type -- -- RW 0 to 3
M_SSEC_MPLMAC_M04_TMMACRO T_STR M[04] program No. -- -- RW 0 to 999999999
M_SSEC_MPLMAC_M05_TMCODE T_SHORT M[05] code -- -- RW 0 to 9999
M_SSEC_MPLMAC_M05_TMMACROT T_CHAR M[05] type -- -- RW 0 to 3
M_SSEC_MPLMAC_M05_TMMACRO T_STR M[05] program No. -- -- RW 0 to 999999999
M_SSEC_MPLMAC_M06_TMCODE T_SHORT M[06] code -- -- RW 0 to 9999
M_SSEC_MPLMAC_M06_TMMACROT T_CHAR M[06] type -- -- RW 0 to 3
M_SSEC_MPLMAC_M06_TMMACRO T_STR M[06] program No. -- -- RW 0 to 999999999
M_SSEC_MPLMAC_M07_TMCODE T_SHORT M[07] code -- -- RW 0 to 9999
M_SSEC_MPLMAC_M07_TMMACROT T_CHAR M[07] type -- -- RW 0 to 3
M_SSEC_MPLMAC_M07_TMMACRO T_STR M[07] program No. -- -- RW 0 to 999999999
M_SSEC_MPLMAC_M08_TMCODE T_SHORT M[08] code -- -- RW 0 to 9999
M_SSEC_MPLMAC_M08_TMMACROT T_CHAR M[08] type -- -- RW 0 to 3
M_SSEC_MPLMAC_M08_TMMACRO T_STR M[08] program No. -- -- RW 0 to 999999999
M_SSEC_MPLMAC_M09_TMCODE T_SHORT M[09] code -- -- RW 0 to 9999
M_SSEC_MPLMAC_M09_TMMACROT T_CHAR M[09] type -- -- RW 0 to 3
M_SSEC_MPLMAC_M09_TMMACRO T_STR M[09] program No. -- -- RW 0 to 999999999
M_SSEC_MPLMAC_M10_TMCODE T_SHORT M[10] code -- -- RW 0 to 9999
M_SSEC_MPLMAC_M10_TMMACROT T_CHAR M[10] type -- -- RW 0 to 3
M_SSEC_MPLMAC_M10_TMMACRO T_STR M[10] program No. -- -- RW 0 to 999999999
M_SSEC_MPLMAC_TBMACROT T_CHAR M2mac type -- -- RW 0 to 3
M_SSEC_MPLMAC_TBMACRO T_STR M2mac program No. -- -- RW 0 to 999999999

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 89 of 206
inventcom

M_SSEC_MPLMAC_G01_TGCODE T_SHORT G[01] code -- -- RW 0 to 999


M_SSEC_MPLMAC_G01_TGMACROT T_CHAR G[01] type -- -- RW 0 to 3
M_SSEC_MPLMAC_G01_TGMACRO T_STR G[01] program No. -- -- RW 0 to 999999999
M_SSEC_MPLMAC_G02_TGCODE T_SHORT G[02] code -- -- RW 0 to 999
M_SSEC_MPLMAC_G02_TGMACROT T_CHAR G[02] type -- -- RW 0 to 3
M_SSEC_MPLMAC_G02_TGMACRO T_STR G[02] program No. -- -- RW 0 to 999999999
M_SSEC_MPLMAC_G03_TGCODE T_SHORT G[03] code -- -- RW 0 to 999
M_SSEC_MPLMAC_G03_TGMACROT T_CHAR G[03] type -- -- RW 0 to 3
M_SSEC_MPLMAC_G03_TGMACRO T_STR G[03] program No. -- -- RW 0 to 999999999
M_SSEC_MPLMAC_G04_TGCODE T_SHORT G[04] code -- -- RW 0 to 999
M_SSEC_MPLMAC_G04_TGMACROT T_CHAR G[04] type -- -- RW 0 to 3
M_SSEC_MPLMAC_G04_TGMACRO T_STR G[04] program No. -- -- RW 0 to 999999999
M_SSEC_MPLMAC_G05_TGCODE T_SHORT G[05] code -- -- RW 0 to 999
M_SSEC_MPLMAC_G05_TGMACROT T_CHAR G[05] type -- -- RW 0 to 3
M_SSEC_MPLMAC_G05_TGMACRO T_STR G[05] program No. -- -- RW 0 to 999999999
M_SSEC_MPLMAC_G06_TGCODE T_SHORT G[06] code -- -- RW 0 to 999
M_SSEC_MPLMAC_G06_TGMACROT T_CHAR G[06] type -- -- RW 0 to 3
M_SSEC_MPLMAC_G06_TGMACRO T_STR G[06] program No. -- -- RW 0 to 999999999
M_SSEC_MPLMAC_G07_TGCODE T_SHORT G[07] code -- -- RW 0 to 999
M_SSEC_MPLMAC_G07_TGMACROT T_CHAR G[07] type -- -- RW 0 to 3
M_SSEC_MPLMAC_G07_TGMACRO T_STR G[07] program No. -- -- RW 0 to 999999999
M_SSEC_MPLMAC_G08_TGCODE T_SHORT G[08] code -- -- RW 0 to 999
M_SSEC_MPLMAC_G08_TGMACROT T_CHAR G[08] type -- -- RW 0 to 3
M_SSEC_MPLMAC_G08_TGMACRO T_STR G[08] program No. -- -- RW 0 to 999999999
M_SSEC_MPLMAC_G09_TGCODE T_SHORT G[09] code -- -- RW 0 to 999
M_SSEC_MPLMAC_G09_TGMACROT T_CHAR G[09] type -- -- RW 0 to 3
M_SSEC_MPLMAC_G09_TGMACRO T_STR G[09] program No. -- -- RW 0 to 999999999
M_SSEC_MPLMAC_G10_TGCODE T_SHORT G[10] code -- -- RW 0 to 999
M_SSEC_MPLMAC_G10_TGMACROT T_CHAR G[10] type -- -- RW 0 to 3
M_SSEC_MPLMAC_G10_TGMACRO T_STR G[10] program No. -- -- RW 0 to 999999999
M_SSEC_MPLMAC_TSMACROT T_CHAR Smac type -- -- RW 0 to 3

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 90 of 206
inventcom

MSTB execution status


Command Data type Description PS AX RW Range
M_SSEC_MSTBE_B_COD T_LONG M command/Manual numerical -- -- RW ±9999999(BCD)/±99999999
command (B1)
M_SSEC_MSTBE_B2_COD T_LONG M command/Manual numerical -- -- RW ±9999999(BCD)/±99999999
command (B2)
M_SSEC_MSTBE_B3_COD T_LONG M command/Manual numerical -- -- RW ±9999999(BCD)/±99999999
command (B3)
M_SSEC_MSTBE_B4_COD T_LONG M command/Manual numerical -- -- RW ±9999999(BCD)/±99999999
command (B4)
M_SSEC_MSTBE_RST_T T_BUFF Restart search T command history O -- R
M_SSEC_MSTBE_RST_S1 T_BUFF Restart search S1 command history -- -- R
M_SSEC_MSTBE_RST_S2 T_BUFF Restart search S2 command history -- -- R
M_SSEC_MSTBE_RST_S3 T_BUFF Restart search S3 command history -- -- R
M_SSEC_MSTBE_RST_S4 T_BUFF Restart search S4 command history -- -- R
M_SSEC_MSTBE_RST_S5 T_BUFF Restart search S5 command history -- -- R
M_SSEC_MSTBE_RST_S6 T_BUFF Restart search S6 command history -- -- R
M_SSEC_MSTBE_RST_B T_BUFF Restart search B command history O -- R
M_SSEC_MSTBE_RST_M T_BUFF Restart search M command history O -- R
M_SSEC_MSTBE_M_COD T_LONG M command/Manual numerical -- -- RW ±9999999(BCD)/±99999999
command (M1)
M_SSEC_MSTBE_M2_COD T_LONG M command/Manual numerical -- -- RW ±9999999(BCD)/±99999999
command (M2)
M_SSEC_MSTBE_M3_COD T_LONG M command/Manual numerical -- -- RW ±9999999(BCD)/±99999999
command (M3)
M_SSEC_MSTBE_M4_COD T_LONG M command/Manual numerical -- -- RW ±9999999(BCD)/±99999999
command (M4)
M_SSEC_MSTBE_S_COD T_LONG M command/Manual numerical -- -- RW ±99999999
command (S1)
M_SSEC_MSTBE_S2_COD T_LONG M command/Manual numerical -- -- RW ±99999999
command (S2)
M_SSEC_MSTBE_S3_COD T_LONG M command/Manual numerical -- -- RW ±99999999
command (S3)
M_SSEC_MSTBE_S4_COD T_LONG M command/Manual numerical -- -- RW ±99999999
command (S4)

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 91 of 206
inventcom

M_SSEC_MSTBE_S5_COD T_LONG M command/Manual numerical -- -- RW ±99999999


command (S5)
M_SSEC_MSTBE_S6_COD T_LONG M command/Manual numerical -- -- RW ±99999999
command (S6)
M_SSEC_MSTBE_T_COD T_LONG M command/Manual numerical -- -- RW ±9999999(BCD)/±99999999
command (T1)

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 92 of 206
inventcom

MSTB modal
Command Data type Description PS AX RW Range
M_SSEC_MSTBMDL_S(x) T_LONG S modal (S1 to S6) (x=1 to 6) -- -- R
M_SSEC_MSTBMDL_T(x) T_LONG T modal (T1 to T2) (x=1 to 2) -- -- R
M_SSEC_MSTBMDL_M(x) T_LONG M modal (M1 to M4) (x=1 to 4) -- -- R
M_SSEC_MSTBMDL_B(x) T_LONG B modal (B1 to B4) (x=1 to 4) -- -- R

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 93 of 206
inventcom

Open parameter1 (long)


Command Data type Description PS AX RW Range
M_SSEC_MPOPN_1_VALUE(x) T_LONG Open parameter value 1(long) (x=1 to -- -- RW -
896)

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 94 of 206
inventcom

Open parameter2 (double)


Command Data type Description PS AX RW Range
M_SSEC_MPOPN_2_VALUE(x) T_DOUBLE Open parameter value 2(long) (x=1 to -- -- RW -
896)

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 95 of 206
inventcom

Operation parameter
Command Data type Description PS AX RW Range
M_SSEC_UPOPE_COUNT_KIND(x) T_UCHAR Counter type 1 to 6 (x=1 to 6) -- -- RW 0 to 255
M_SSEC_UPOPE_AUT_MANU_SW T_CHAR Display switch between -- -- RW 0 to 2
automatic/manual
M_SSEC_UPOPE_EDIT_UNDO T_CHAR Edit undo enabled -- -- RW 0,1
M_SSEC_UPOPE_TOPSEARCH_AUTO T_CHAR Auto top search -- -- RW 0,1
M_SSEC_UPOPE_AUTO_BACKUP_DAY1 T_CHAR Auto backup day 1 -- -- RW -1 to 31
M_SSEC_UPOPE_AUTO_BACKUP_DAY2 T_CHAR Auto backup day 2 -- -- RW 0 to 31
M_SSEC_UPOPE_AUTO_BACKUP_DAY3 T_CHAR Auto backup day 3 -- -- RW 0 to 31
M_SSEC_UPOPE_AUTO_BACKUP_DAY4 T_CHAR Auto backup day 4 -- -- RW 0 to 31
M_SSEC_UPOPE_AUTO_BACKUP_DEV T_CHAR Auto backup device -- -- RW 0 to 2
M_SSEC_UPOPE_3D_TOFS_SELECT T_CHAR 3D tool ofs select -- -- RW 0,1
M_SSEC_UPOPE_MASS_EDIT_SELECT T_CHAR Mass edit select -- -- RW 0,1
M_SSEC_UPOPE_TREG_REPEAT_INVALID T_CHAR T-register duplication check disabled -- -- RW 0,1
M_SSEC_UPOPE_HIDE_EDIT_IO_MENU T_CHAR Hide Edit-IO menu -- -- RW 0,1
M_SSEC_UPOPE_MEAS_CONFIRM_MSG T_CHAR Measure-Confirmation message exists -- -- RW 0,1
M_SSEC_UPOPE_SYS1_SPNO T_CHAR Spindle No. on part sys 1 display -- -- RW 0x00 to 0x66
M_SSEC_UPOPE_SYS2_SPNO T_CHAR Spindle No. on part sys 2 display -- -- RW 0x00 to 0x66
M_SSEC_UPOPE_SYS3_SPNO T_CHAR Spindle No. on part sys 3 display -- -- RW 0x00 to 0x66
M_SSEC_UPOPE_SYS4_SPNO T_CHAR Spindle No. on part sys 4 display -- -- RW 0x00 to 0x66
M_SSEC_UPOPE_OFS_ABSINPUT T_CHAR 5Input menu disabled: Compensation -- -- RW 0,1
M_SSEC_UPOPE_VAR_ABSINPUT T_CHAR 5Input menu disabled: Variable -- -- RW 0,1
M_SSEC_UPOPE_DIS_SET_LIMIT T_CHAR Remote display/setting operation limit -- -- RW 0 to 2
M_SSEC_UPOPE_HIDE_MEAS_SCRN T_CHAR Hide measure screen -- -- RW 0,1
M_SSEC_UPOPE_TOOLOFS_INPUT T_CHAR Prohibit shape compensation amount -- -- RW 0,1
setting
M_SSEC_UPOPE_WEAROFS_INPUT T_CHAR Prohibit wear compensation amount -- -- RW 0,1
setting

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 96 of 206
inventcom

Operation status
Command Data type Description PS AX RW Range
M_SSEC_EXST_MACRO_EXEC_LV T_CHAR Macro execution level O -- R
M_SSEC_EXST_BUSY_COLLATION T_LONG Executing verification stop O -- RW 0
M_SSEC_EXST_COLLATION_O T_STR Verification stop O No. O -- R
M_SSEC_EXST_COLLATION_N T_LONG Verification stop N No. O -- R
M_SSEC_EXST_COLLATION_B T_LONG Verification stop B No. O -- R
M_SSEC_EXST_COLLATION_PATH T_STR Verification stop path name O -- R
M_SSEC_EXST_NC_RUN_STATUS T_SHORT Operation status 1 (Operation status) O -- R 0: RST, 1: EMG, 2: RDY, 3: AUT,4:
SYN,5: CRS,6: BST,7: HLD
M_SSEC_EXST_NC_RUN_MODE T_SHORT Operation status 2 (Operation mode) O -- R 0: MEM,1: 232,2: LNK,3: MDI,4:
PC,5: MNL,6: JOG,7: J+H,8: R+H,
9: HDL,10: STP,11: STP,12:
ZRN,13: DRT,14: INI,15: NON,16:
LIN
M_SSEC_EXST_AUTO_STL T_LONG Automatic operation in progress O -- R
M_SSEC_EXST_OPERATION T_LONG Executing automatic operation O -- R
M_SSEC_EXST_STOP_OPERATION T_LONG Automatic operation is stopped O -- R
M_SSEC_EXST_LOCK_KEY_1 T_LONG Data lock key 1 O -- R
M_SSEC_EXST_LOCK_KEY_2 T_LONG Data lock key 2 O -- R
M_SSEC_EXST_LOCK_KEY_3 T_LONG Data lock key 3 O -- R
M_SSEC_EXST_PISW1 T_SHORT External input signal 1 O -- R
M_SSEC_EXST_PIJSP T_CHAR JOG mode (special) signal O -- R
M_SSEC_EXST_PODT1 T_SHORT NC status output signal 1 O -- R
M_SSEC_EXST_POAL T_CHAR Alarm status signal O -- R
M_SSEC_EXST_AUTO_MOD T_CHAR Operation (automatic) mode related O -- R
signal
M_SSEC_EXST_MANU_MOD T_CHAR Operation (manual) mode related signal O -- R
M_SSEC_EXST_RST_STS T_LONG Restart search status O -- R
M_SSEC_EXST_RST_TP1STS T_LONG Restart search type 1 enabled O -- R
M_SSEC_EXST_EXSRCH_STS T_LONG Extended operation search status O -- R
M_SSEC_EXST_EXSRCH_LINE T_LONG Current line number during search O -- R
M_SSEC_EXST_CHECK_STS T_LONG Check status O -- R
M_SSEC_EXST_PRON T_LONG Parameter flag to demand power ON -- -- R
again

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 97 of 206
inventcom

M_SSEC_EXST_PLC_RUN_STOP T_LONG PLC Run/Stop status -- -- R 0 to 1


M_SSEC_EXST_MDI_STS T_LONG MDI setting status O -- R 0 to 3

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 98 of 206
inventcom

PLC axis indexing parameter


Command Data type Description PS AX RW Range
M_SSEC_PLCINDXPRM_CHGAUXNO T_CHAR Auxiliary axis No. - O RW 0 to 6
M_SSEC_PLCINDXPRM_STATION T_SHORT The number of indexing stations - O RW 2 to 360
M_SSEC_PLCINDXPRM_CONT1 T_SHORT Control parameter 1 - O RW 0 to 0xFFFF
M_SSEC_PLCINDXPRM_CONT2 T_SHORT Control parameter 2 - O RW 0 to 0xFFFF
M_SSEC_PLCINDXPRM_TLENG T_FLOATBIN Stroke length of linear axis - O RW 1 to 99999.999
M_SSEC_PLCINDXPRM_STOFSET T_FLOATBIN Station offset - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_ASPEED1 T_LONG Operation parameter group 1 - O RW 1 to 100000
Automatic operation speed
M_SSEC_PLCINDXPRM_MSPEED1 T_LONG Operation parameter group 1 Manual - O RW 1 to 100000
operation speed
M_SSEC_PLCINDXPRM_TIMEL1 T_SHORT Operation parameter group 1 - O RW 1 to 9999
Acceleration/deceleration time constant
1
M_SSEC_PLCINDXPRM_TIMEL2 T_SHORT Operation parameter group 1 - O RW 1 to 999
Acceleration/deceleration time constant
2
M_SSEC_PLCINDXPRM_TL1 T_SHORT Operation parameter group 1 Torque - O RW 1 to 500
limit value
M_SSEC_PLCINDXPRM_OD1 T_SHORT Operation parameter group 1 Excessive - O RW 0 to 32767
error detection width
M_SSEC_PLCINDXPRM_JUST1 T_FLOATBIN Operation parameter group 1 Set - O RW 0 to 99999.999
position output width
M_SSEC_PLCINDXPRM_NEAR1 T_FLOATBIN Operation parameter group 1 Near set - O RW 0 to 99999.999
position output width
M_SSEC_PLCINDXPRM_SMGST1 T_SHORT Operation parameter group 1 - O RW 0x01,0x0F
Acceleration/deceleration type
M_SSEC_PLCINDXPRM_ASPEED2 T_LONG Operation parameter group 2 - O RW 1 to 100000
Automatic operation speed
M_SSEC_PLCINDXPRM_MSPEED2 T_LONG Operation parameter group 2 Manual - O RW 1 to 100000
operation speed
M_SSEC_PLCINDXPRM_TIMEL2_1 T_SHORT Operation parameter group 2 - O RW 1 to 9999
Acceleration/deceleration time constant
1

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 99 of 206
inventcom

M_SSEC_PLCINDXPRM_TIMEL2_2 T_SHORT Operation parameter group 2 - O RW 1 to 999


Acceleration/deceleration time constant
2

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 100 of 206
inventcom

PLC constant
Command Data type Description PS AX RW Range
M_SSEC_MP_PLC_CONST(x) T_LONG PLC constant (x=0 to 95 / [M7] x=0 to -- -- RW -99999999 to 99999999
899)

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 101 of 206
inventcom

PLC counter
Command Data type Description PS AX RW Range
M_SSEC_MP_PLC_COUNTER(x) T_SHORT Counter (x=0 to 23 / [M7] x=0 to 255) -- -- RW 0 to 65535
M_SSEC_MP_PLC_COUNTER_NOS T_SHORT Number of times of PLC counter -- -- R
(variable) (Only for M7)
M_SSEC_MP_PLC_COUNTER_STS(x) T_CHAR PLC counter device used status (x=0 to -- -- R BIT0 - ON: Used/OFF: Not used
256) BIT1 - ON: Constant/OFF: Variable

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 102 of 206
inventcom

PLC device (bit)


Command Data type Description PS AX RW Range
M_SSEC_PLBIT_X_1SHOT(x) T_CHAR Device X (x=0 to 2815 / [M7] x=0 to -- -- RW 0,1
8191)
M_SSEC_PLBIT_Y_1SHOT(x) T_CHAR Device Y (x=0 to 3583 / [M7] x=0 to -- -- RW 0,1
8191)
M_SSEC_PLBIT_M_1SHOT(x) T_CHAR Device M (x=0 to 8191 / [M7] x=0 to -- -- RW 0,1
10239)
M_SSEC_PLBIT_F_1SHOT(x) T_CHAR Device F (x=0 to 255 / [M7] x=0 to -- -- RW 0,1
1024)
M_SSEC_PLBIT_L_1SHOT(x) T_CHAR Device L (x=0 to 255 / [M7] x=0 to 511) -- -- RW 0,1
M_SSEC_PLBIT_SM_1SHOT(x) T_CHAR Device SM (x=0 to 127)(GPPW) -- -- RW 0,1
M_SSEC_PLBIT_T_1SHOT(x) T_CHAR Device T (x=0 to 1255 / [M7] x=0 to -- -- RW 0,1
1703)
M_SSEC_PLBIT_C_1SHOT(x) T_CHAR Device C (x=0 to 1127 / [M7] x=0 to -- -- RW 0,1
1255)
M_SSEC_PLBIT_E_1SHOT(x) T_CHAR Device E (x=0 to 127)(PLC4B) -- -- RW 0,1
M_SSEC_PLBIT_U_1SHOT(x) T_CHAR Device U (x=0 to 383)(PLC4B) -- -- RW 0,1
M_SSEC_PLBIT_W_1SHOT(x) T_CHAR Device W (x=0 to 511)(PLC4B) -- -- RW 0,1
M_SSEC_PLBIT_B_1SHOT(x) T_CHAR Device B (x=0 to 1103 / [M7] x=0 to -- -- RW 0,1
8191)(PLC4B/NET10)
M_SSEC_PLBIT_G_1SHOT(x) T_CHAR Device G (x=0 to 3071)(PLC4B) -- -- RW 0,1
M_SSEC_PLBIT_I_1SHOT(x) T_CHAR Device I (x=0 to 1023)(PLC4B) -- -- RW 0,1
M_SSEC_PLBIT_J_1SHOT(x) T_CHAR Device J (x=0 to 1599)(PLC4B) -- -- RW 0,1
M_SSEC_PLBIT_Q_1SHOT(x) T_CHAR Device Q (x=0 to 1151)(PLC4B) -- -- RW 0,1
M_SSEC_PLBIT_S_1SHOT(x) T_CHAR Device S (x=0 to 319)(PLC4B) -- -- RW 0,1
M_SSEC_PLBIT_SB_1SHOT(x) T_CHAR Device SB (x=0 to 511)(NET10) -- -- RW 0,1
M_SSEC_PLBIT_V_1SHOT(x) T_CHAR Device V (x=0 to 255)(NET10) -- -- RW 0,1
M_SSEC_PLBIT_ST_1SHOT(x) T_CHAR Device ST (x=0 to 1063)(M7 GPPW) -- -- RW 0,1

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 103 of 206
inventcom

PLC device (char)


Command Data type Description PS AX RW Range
M_SSEC_PLCHR_X_1SHOT(x) T_CHAR Device X (x=0 to 2815 / [M7] x=0 to -- -- RW 0x00 to 0xFF
8191)
M_SSEC_PLCHR_Y_1SHOT(x) T_CHAR Device Y (x=0 to 3583 / [M7] x=0 to -- -- RW 0x00 to 0xFF
8191)
M_SSEC_PLCHR_M_1SHOT(x) T_CHAR Device M (x=0 to 8191 / [M7] x=0 to -- -- RW 0x00 to 0xFF
10239)
M_SSEC_PLCHR_F_1SHOT(x) T_CHAR Device F (x=0 to 255 / [M7] x=0 to -- -- RW 0x00 to 0xFF
1024)
M_SSEC_PLCHR_L_1SHOT(x) T_CHAR Device L (x=0 to 255 / [M7] x=0 to 511) -- -- RW 0x00 to 0xFF
M_SSEC_PLCHR_SM_1SHOT(x) T_CHAR Device SM (x=0 to 127)(GPPW) RW 0x00 to 0xFF
M_SSEC_PLCHR_T_1SHOT(x) T_CHAR Device T (x=0 to 1255 / [M7] x=0 to -- -- RW 0x00 to 0xFF
1703)
M_SSEC_PLCHR_C_1SHOT(x) T_CHAR Device C (x=0 to 1127 / [M7] x=0 to -- -- RW 0x00 to 0xFF
1255)
M_SSEC_PLCHR_E_1SHOT(x) T_CHAR Device E (x=0 to 127)(PLC4B) -- -- RW 0x00 to 0xFF
M_SSEC_PLCHR_U_1SHOT(x) T_CHAR Device U (x=0 to 383)(PLC4B) -- -- RW 0x00 to 0xFF
M_SSEC_PLCHR_W_1SHOT(x) T_CHAR Device W (x=0 to 511)(PLC4B) -- -- RW 0x00 to 0xFF
M_SSEC_PLCHR_B_1SHOT(x) T_CHAR Device B (x=0 to 1103 / [M7] x=0 to -- -- RW 0x00 to 0xFF
8191) (PLC4B/NET10)
M_SSEC_PLCHR_G_1SHOT(x) T_CHAR Device G (x=0 to 3071)(PLC4B) -- -- RW 0x00 to 0xFF
M_SSEC_PLCHR_I_1SHOT(x) T_CHAR Device I (x=0 to 1023)(PLC4B) -- -- RW 0x00 to 0xFF
M_SSEC_PLCHR_J_1SHOT(x) T_CHAR Device J (x=0 to 1599)(PLC4B) -- -- RW 0x00 to 0xFF
M_SSEC_PLCHR_Q_1SHOT(x) T_CHAR Device Q (x=0 to 1151)(PLC4B) -- -- RW 0x00 to 0xFF
M_SSEC_PLCHR_S_1SHOT(x) T_CHAR Device S (x=0 to 319)(PLC4B) -- -- RW 0x00 to 0xFF
M_SSEC_PLCHR_SB_1SHOT(x) T_CHAR Device SB (x=0 to 511)(NET10) -- -- RW 0x00 to 0xFF
M_SSEC_PLCHR_V_1SHOT(x) T_CHAR Device V (x=0 to 255)(NET10) -- -- RW 0x00 to 0xFF
M_SSEC_PLCHR_ST_1SHOT(x) T_CHAR Device ST (x=0 to 1063)(M7 GPPW) -- -- RW 0x00 to 0xFF

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 104 of 206
inventcom

PLC device (long)


Command Data type Description PS AX RW Range
M_SSEC_PLLNG_X_1SHOT(x) T_LONG Device X (x=0 to 2815 / [M7] x=0 to -- -- RW 0x00000000 to 0xFFFFFFFF
8191)
M_SSEC_PLLNG_Y_1SHOT(x) T_LONG Device Y (x=0 to 3583 / [M7] x=0 to -- -- RW 0x00000000 to 0xFFFFFFFF
8191)
M_SSEC_PLLNG_M_1SHOT(x) T_LONG Device M (x=0 to 8191 / [M7] x=0 to -- -- RW 0x00000000 to 0xFFFFFFFF
10239)
M_SSEC_PLLNG_F_1SHOT(x) T_LONG Device F (x=0 to 255 / [M7] x=0 to -- -- RW 0x00000000 to 0xFFFFFFFF
1024)
M_SSEC_PLLNG_L_1SHOT(x) T_LONG Device L (x=0 to 255 / [M7] x=0 to 511) -- -- RW 0x00000000 to 0xFFFFFFFF
M_SSEC_PLLNG_SM_1SHOT(x) T_LONG Device SM (x=0 to 127)(GPPW) -- -- RW 0x00000000 to 0xFFFFFFFF
M_SSEC_PLLNG_T_1SHOT(x) T_LONG Device T (x=0 to 4255 / [M7] x=0 to -- -- RW 0x00000000 to 0xFFFFFFFF
4703)
M_SSEC_PLLNG_C_1SHOT(x) T_LONG Device C (x=0 to 4127 / [M7] x=0 to -- -- RW 0x00000000 to 0xFFFFFFFF
4255)
M_SSEC_PLLNG_D_1SHOT(x) T_LONG Device D (x=0 to 1023 / [M7] x=0 to -- -- RW 0x00000000 to 0xFFFFFFFF
2047)
M_SSEC_PLLNG_R_1SHOT(x) T_LONG Device R (x=0 to 8191 / [M7] x=0 to -- -- RW 0x00000000 to 0xFFFFFFFF
13311)
M_SSEC_PLLNG_E_1SHOT(x) T_LONG Device E (x=0 to 127) -- -- RW 0x00000000 to 0xFFFFFFFF
M_SSEC_PLLNG_U_1SHOT(x) T_LONG Device U (x=0 to 383)(PLC4B) -- -- RW 0x00000000 to 0xFFFFFFFF
M_SSEC_PLLNG_W_1SHOT(x) T_LONG Device W (x=0 to 511 /[M7] x=0 to -- -- RW 0x00000000 to 0xFFFFFFFF
8191) (PLC4B/NET10)
M_SSEC_PLLNG_B_1SHOT(x) T_LONG Device B (x=0 to 4103 /[M7] x=0 to -- -- RW 0x00000000 to 0xFFFFFFFF
8191) (PLC4B/NET10)
M_SSEC_PLLNG_G_1SHOT(x) T_LONG Device G (x=0 to 3071)(PLC4B) -- -- RW 0x00000000 to 0xFFFFFFFF
M_SSEC_PLLNG_I_1SHOT(x) T_LONG Device I (x=0 to 1023)(PLC4B) -- -- RW 0x00000000 to 0xFFFFFFFF
M_SSEC_PLLNG_J_1SHOT(x) T_LONG Device J (x=0 to 1599)(PLC4B) -- -- RW 0x00000000 to 0xFFFFFFFF
M_SSEC_PLLNG_Q_1SHOT(x) T_LONG Device Q (x=0 to 4151)(PLC4B) -- -- RW 0x00000000 to 0xFFFFFFFF
M_SSEC_PLLNG_S_1SHOT(x) T_LONG Device S (x=0 to 319)(PLC4B) -- -- RW 0x00000000 to 0xFFFFFFFF
M_SSEC_PLLNG_SB_1SHOT(x) T_LONG Device SB (x=0 to 511) (NET10) -- -- RW 0x00000000 to 0xFFFFFFFF
M_SSEC_PLLNG_V_1SHOT(x) T_LONG Device V (x=0 to 255) (NET10) -- -- RW 0x00000000 to 0xFFFFFFFF
M_SSEC_PLLNG_SW_1SHOT(x) T_LONG Device SW (x=0 to 511) (NET10) -- -- RW 0x00000000 to 0xFFFFFFFF
M_SSEC_PLLNG_SD_1SHOT(x) T_LONG Device SD (x=0 to 127) (NET10) -- -- RW 0x00000000 to 0xFFFFFFFF

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 105 of 206
inventcom

M_SSEC_PLLNG_ST_1SHOT(x) T_LONG Device ST (x=0 to 4063)(M7 GPPW) -- -- RW 0x00000000 to 0xFFFFFFFF

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 106 of 206
inventcom

PLC device (word)


Command Data type Description PS AX RW Range
M_SSEC_PLWRD_X_1SHOT(x) T_SHORT Device X (x=0 to 2815 / [M7] x=0 to -- -- RW 0x0000 to 0xFFFF
8191)
M_SSEC_PLWRD_Y_1SHOT(x) T_SHORT Device Y (x=0 to 3583 / [M7] x=0 to -- -- RW 0x0000 to 0xFFFF
8191)
M_SSEC_PLWRD_M_1SHOT(x) T_SHORT Device M (x=0 to 8191 / [M7] x=0 to -- -- RW 0x0000 to 0xFFFF
10239)
M_SSEC_PLWRD_F_1SHOT(x) T_SHORT Device F (x=0 to 255 / [M7] x=0 to -- -- RW 0x0000 to 0xFFFF
1024)
M_SSEC_PLWRD_L_1SHOT(x) T_SHORT Device L (x=0 to 255 / [M7] x=0 to 511) -- -- RW 0x0000 to 0xFFFF
M_SSEC_PLWRD_SM_1SHOT(x) T_SHORT Device SM (x=0 to 127)(GPPW) -- -- RW 0x0000 to 0xFFFF
M_SSEC_PLWRD_T_1SHOT(x) T_SHORT Device T (x=0 to 4255 / [M7] x=0 to -- -- RW 0x0000 to 0xFFFF
4703)
M_SSEC_PLWRD_C_1SHOT(x) T_SHORT Device C (x=0 to 4127 / [M7] x=0 to -- -- RW 0x0000 to 0xFFFF
4255)
M_SSEC_PLWRD_D_1SHOT(x) T_SHORT Device D (x=0 to 1023 / [M7] x=0 to -- -- RW 0x0000 to 0xFFFF
2047)
M_SSEC_PLWRD_R_1SHOT(x) T_SHORT Device R (x=0 to 8191 / [M7] x=0 to -- -- RW 0x0000 to 0xFFFF
13311)
M_SSEC_PLWRD_E_1SHOT(x) T_SHORT Device E (x=0 to 127)(PLC4B) -- -- RW 0x0000 to 0xFFFF
M_SSEC_PLWRD_U_1SHOT(x) T_SHORT Device U (x=0 to 383)(PLC4B) -- -- RW 0x0000 to 0xFFFF
M_SSEC_PLWRD_W_1SHOT(x) T_SHORT Device W (x=0 to 511 /[M7] x=0 to -- -- RW 0x0000 to 0xFFFF
8191) (PLC4B/NET10)
M_SSEC_PLWRD_B_1SHOT(x) T_SHORT Device B (x=0 to 4103 /[M7] x=0 to -- -- RW 0x0000 to 0xFFFF
8191) (PLC4B/NET10)
M_SSEC_PLWRD_G_1SHOT(x) T_SHORT Device G (x=0 to 3071)(PLC4B) -- -- RW 0x0000 to 0xFFFF
M_SSEC_PLWRD_I_1SHOT(x) T_SHORT Device I (x=0 to 1023)(PLC4B) -- -- RW 0x0000 to 0xFFFF
M_SSEC_PLWRD_J_1SHOT(x) T_SHORT Device J (x=0 to 1599)(PLC4B) -- -- RW 0x0000 to 0xFFFF
M_SSEC_PLWRD_Q_1SHOT(x) T_SHORT Device Q (x=0 to 4151)(PLC4B) -- -- RW 0x0000 to 0xFFFF
M_SSEC_PLWRD_S_1SHOT(x) T_SHORT Device S (x=0 to 319)(PLC4B) -- -- RW 0x0000 to 0xFFFF
M_SSEC_PLWRD_SB_1SHOT(x) T_SHORT Device SB (x=0 to 511) (NET10) -- -- RW 0x0000 to 0xFFFF
M_SSEC_PLWRD_V_1SHOT(x) T_SHORT Device V (x=0 to 255) (NET10) -- -- RW 0x0000 to 0xFFFF
M_SSEC_PLWRD_SW_1SHOT(x) T_SHORT Device SW (x=0 to 511) (NET10) -- -- RW 0x0000 to 0xFFFF
M_SSEC_PLWRD_SD_1SHOT(x) T_SHORT Device SD (x=0 to 127) (NET10) -- -- RW 0x0000 to 0xFFFF

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 107 of 206
inventcom

M_SSEC_PLWRD_ST_1SHOT(x) T_SHORT Device ST (x=0 to 4063)(M7 GPPW) -- -- RW 0x0000 to 0xFFFF

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 108 of 206
inventcom

PLC forced output


Command Data type Description PS AX RW Range
M_SSEC_PLFOUT_BIT_C(x) T_LONG Device C(bit) (x=0 to 4127 / [M7] x=0 to -- -- W 0,1
4255)
M_SSEC_PLFOUT_BIT_E(x) T_LONG Device E(bit) (x=0 to 127) -- -- W 0,1
M_SSEC_PLFOUT_BIT_F(x) T_LONG Device F(bit) (x=0 to 255 / [M7] x=0 to -- -- W 0,1
1024)
M_SSEC_PLFOUT_BIT_L(x) T_LONG Device L(bit) (x=0 to 255 / [M7] x=0 to -- -- W 0,1
511)
M_SSEC_PLFOUT_BIT_M(x) T_LONG Device M(bit) (x=0 to 8191 / [M7] x=0 -- -- W 0,1
to 10239)
M_SSEC_PLFOUT_BIT_T(x) T_LONG Device T(bit) (x=0 to 4255 / [M7] x=0 to -- -- W 0,1
4703)
M_SSEC_PLFOUT_BIT_X(x) T_LONG Device X(bit) (x=0 to 0xAFF/ [M7] x=0 -- -- W 0,1
to 0x1FFF)
M_SSEC_PLFOUT_BIT_Y(x) T_LONG Device Y(bit) (x=0 to 0xDFF/ [M7] x=0 -- -- W 0,1
to 0x1FFF)
M_SSEC_PLFOUT_BIT_U(x) T_LONG Device U(bit) (x=0 to 383)(PLC4B) -- -- W 0,1
M_SSEC_PLFOUT_BIT_W(x) T_LONG Device W(bit) (x=0 to 511)(PLC4B) -- -- W 0,1
M_SSEC_PLFOUT_BIT_B(x) T_LONG Device B(bit) (x=0 to 4103 /[M7] x=0 to -- -- W 0,1
0x1FFF) (PLC4B/NET10)
M_SSEC_PLFOUT_BIT_G(x) T_LONG Device G(bit) (x=0 to 3071)(PLC4B) -- -- W 0,1
M_SSEC_PLFOUT_BIT_I(x) T_LONG Device I(bit) (x=0 to 1023)(PLC4B) -- -- W 0,1
M_SSEC_PLFOUT_BIT_J(x) T_LONG Device J(bit) (x=0 to 1599)(PLC4B) -- -- W 0,1
M_SSEC_PLFOUT_BIT_Q(x) T_LONG Device Q(bit) (x=0 to 4151)(PLC4B) -- -- W 0,1
M_SSEC_PLFOUT_BIT_S(x) T_LONG Device S(bit) (x=0 to 319)(PLC4B) -- -- W 0,1
M_SSEC_PLFOUT_BIT_SM(x) T_LONG Device SM(bit) (x=0 to 127)(GPPW) -- -- W 0,1
M_SSEC_PLFOUT_BIT_SB(x) T_LONG Device SB(bit) (x=0 to 0x1FF) (NET10) -- -- W 0,1
M_SSEC_PLFOUT_BIT_V(x) T_LONG Device V(bit) (x=0 to 255) (NET10) -- -- W 0,1
M_SSEC_PLFOUT_BIT_ST(x) T_LONG Device ST(bit) (x=0 to 4063) (M7 -- -- W 0,1
GPPW)
M_SSEC_PLFOUT_WRD_D(x) T_LONG Device D(word) (x=0 to 1023 / [M7] -- -- W 0x0000 to 0xFFFF
x=0 to 2047)
M_SSEC_PLFOUT_WRD_R(x) T_LONG Device R(word) (x=0 to 8191 / [M7] x=0 -- -- W 0x0000 to 0xFFFF
to 13311)

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 109 of 206
inventcom

M_SSEC_PLFOUT_WRD_SW(x) T_LONG Device SW(word) (x=0 to 0x1FF ) -- -- W 0x0000 to 0xFFFF


(NET10)
M_SSEC_PLFOUT_WRD_SD(x) T_LONG Device SD(word) (x=0 to 127 ) (NET10) -- -- W 0x0000 to 0xFFFF
M_SSEC_PLFOUT_WRD_W(x) T_LONG Device W (word) (x=0 to 0x1FFF) -- -- W 0x0000 to 0xFFFF
(NET10)
M_SSEC_PLFOUT_CANCEL T_LONG Device modal output cancel -- -- W 1 to 4
M_SSEC_PLFOUT_FOUT(x) T_STR Device modal output (x=1 to 4) -- -- RW Character string (E.g.
X/0123/0001)
M_SSEC_PLFOUT_FOUT2(x) T_STR Device modal output 2 (2 letters of T, -- -- RW Character string (E.g.
C, 3 letters of ST) (x=1 to 4) TI/0001/0001)
M_SSEC_PLFOUT_1SHOT2 T_STR Device 1-shot output -- -- W Character string (E.g. TI/123/0001)
M_SSEC_PLFOUT_X_NOS T_LONG The number of points of device X -- -- R
(GPPW)
M_SSEC_PLFOUT_Y_NOS T_LONG The number of points of device Y -- -- R
(GPPW)
M_SSEC_PLFOUT_M_NOS T_LONG The number of points of device M -- -- R
(GPPW)
M_SSEC_PLFOUT_F_NOS T_LONG The number of points of device F -- -- R
(GPPW)
M_SSEC_PLFOUT_L_NOS T_LONG The number of points of device L -- -- R
(GPPW)
M_SSEC_PLFOUT_SM_NOS T_LONG The number of points of device SM -- -- R
(GPPW)
M_SSEC_PLFOUT_T_NOS T_LONG The number of points of device T -- -- R
(GPPW)
M_SSEC_PLFOUT_C_NOS T_LONG The number of points of device C -- -- R
(GPPW)
M_SSEC_PLFOUT_V_NOS T_LONG The number of points of device V -- -- R
(GPPW)
M_SSEC_PLFOUT_D_NOS T_LONG The number of points of device D -- -- R
(GPPW)
M_SSEC_PLFOUT_R_NOS T_LONG The number of points of device R -- -- R
(GPPW)
M_SSEC_PLFOUT_SB_NOS T_LONG The number of points of device SB -- -- R
(NET10)
M_SSEC_PLFOUT_B_NOS T_LONG The number of points of device B -- -- R
(NET10)

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 110 of 206
inventcom

M_SSEC_PLFOUT_SW_NOS T_LONG The number of points of device SW -- -- R


(NET10)
M_SSEC_PLFOUT_SD_NOS T_LONG The number of points of device SD -- -- R
(NET10)
M_SSEC_PLFOUT_W_NOS T_LONG The number of points of device W -- -- R
(NET10)
M_SSEC_PLFOUT_ST_NOS T_LONG The number of points of device ST (M7 -- -- R
GPPW)

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 111 of 206
inventcom

PLC switch
Command Data type Description PS AX RW Range
M_SSEC_UP_PLC_SWITCH_X(x) T_CHAR PLC switch X (IN) (x=1 to 32) -- -- RW 0,1
M_SSEC_UP_PLC_SWITCH_Y(x) T_CHAR PLC switch Y (OUT) (x=1 to 32) -- -- R
M_SSEC_UP_PLCSW_IN0 T_SHORT PLC switch X (IN) 1 to 16 -- -- RW 0x0000 to 0xFFFF
M_SSEC_UP_PLCSW_IN1 T_SHORT PLC switch X (IN) 17 to 32 -- -- RW 0x0000 to 0xFFFF
M_SSEC_UP_PLCSW_OUT0 T_SHORT PLC switch Y (OUT) 1 to 16 -- -- RW 0x0000 to 0xFFFF
M_SSEC_UP_PLCSW_OUT1 T_SHORT PLC switch Y (OUT) 17 to 32 -- -- R 0x0000 to 0xFFFF

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 112 of 206
inventcom

PLC timer
Command Data type Description PS AX RW Range
M_SSEC_MP_PLC_TIMER10(x) T_LONG 10ms timer <10ms> (x=0 to 15 / [M7] -- -- RW 0 to 65535
x=0 to 703)
M_SSEC_MP_PLC_TIMER100(x) T_LONG 100ms timer <100ms> (x=0 to 79 / -- -- RW 0 to 65535
[M7] x=0 to 703)
M_SSEC_MP_PLC_TIMER100INC(x) T_LONG 100ms cumulative timer <100msINC> -- -- RW 0 to 65535
(x=0 to 7 / [M7] x=0 to 63)
M_SSEC_MP_PLC_EX_TIMER10(x) T_LONG 10ms additional extension timer -- -- RW 0 to 65535
<10ms> (x=0 to 399 / [M7]
Unavailable)
M_SSEC_MP_PLC_TIMER_NOS T_SHORT Number of times of PLC timers -- -- R
(variable) (Only for M7)
M_SSEC_MP_PLC_TIMERINC_NOS T_SHORT Number of times of PLC cumulative -- -- R
timer (variable) (Only for M7)
M_SSEC_MP_PLC_TIMER_STS(x) T_CHAR PLC timer device used status (x=0 to -- -- R BIT0 - ON: Used/OFF: Not used
703) BIT1 - ON: Constant/OFF: Variable
BIT2 - ON: 10ms/OFF: 100ms
M_SSEC_MP_PLC_TIMER_INC_STS(x) T_CHAR PLC cumulative timer device used -- -- R BIT0 - ON: Used/OFF: Not used
status (x=0 to 63) BIT1 - ON: Constant/OFF: Variable

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 113 of 206
inventcom

Position switch
Command Data type Description PS AX RW Range
M_SSEC_MPPOSW_CKPSW T_CHAR PSW switch -- -- RW 0,1
M_SSEC_MPPOSW_PSW1_PAXNAM T_STR 1st position switch axis name O -- RW Character string (Axis address of
#1013)
M_SSEC_MPPOSW_PSW1_DOG1 T_FLOATBIN/T_LONG 1st position switch hypothetical dog O -- RW ±99999.999
position 1
M_SSEC_MPPOSW_PSW1_DOG2 T_FLOATBIN/T_LONG 1st position switch hypothetical dog O -- RW ±99999.999
position 2
M_SSEC_MPPOSW_PSW1_CKTYP T_CHAR 1st position switch PSW check method O -- RW 0,1
switch
M_SSEC_MPPOSW_PSW2_PAXNAM T_STR 2nd position switch axis name O -- RW Character string (Axis address of
#1013)
M_SSEC_MPPOSW_PSW2_DOG1 T_FLOATBIN/T_LONG 2nd position switch hypothetical dog O -- RW ±99999.999
position 1
M_SSEC_MPPOSW_PSW2_DOG2 T_FLOATBIN/T_LONG 2nd position switch hypothetical dog O -- RW ±99999.999
position 2
M_SSEC_MPPOSW_PSW2_CKTYP T_CHAR 2nd position switch PSW check O -- RW 0,1
method switch
M_SSEC_MPPOSW_PSW3_PAXNAM T_STR 3rd position switch axis name O -- RW Character string (Axis address of
#1013)
M_SSEC_MPPOSW_PSW3_DOG1 T_FLOATBIN/T_LONG 3rd position switch hypothetical dog O -- RW ±99999.999
position 1
M_SSEC_MPPOSW_PSW3_DOG2 T_FLOATBIN/T_LONG 3rd position switch hypothetical dog O -- RW ±99999.999
position 2
M_SSEC_MPPOSW_PSW3_CKTYP T_CHAR 3rd position switch PSW check method O -- RW 0,1
switch
M_SSEC_MPPOSW_PSW4_PAXNAM T_STR 4th position switch axis name O -- RW Character string (Axis address of
#1013)
M_SSEC_MPPOSW_PSW4_DOG1 T_FLOATBIN/T_LONG 4th position switch hypothetical dog O -- RW ±99999.999
position 1
M_SSEC_MPPOSW_PSW4_DOG2 T_FLOATBIN/T_LONG 4th position switch hypothetical dog O -- RW ±99999.999
position 2
M_SSEC_MPPOSW_PSW4_CKTYP T_CHAR 4th position switch PSW check method O -- RW 0,1
switch

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 114 of 206
inventcom

M_SSEC_MPPOSW_PSW5_PAXNAM T_STR 5th position switch axis name O -- RW Character string (Axis address of
#1013)
M_SSEC_MPPOSW_PSW5_DOG1 T_FLOATBIN/T_LONG 5th position switch hypothetical dog O -- RW ±99999.999
position 1
M_SSEC_MPPOSW_PSW5_DOG2 T_FLOATBIN/T_LONG 5th position switch hypothetical dog O -- RW ±99999.999
position 2
M_SSEC_MPPOSW_PSW5_CKTYP T_CHAR 5th position switch PSW check method O -- RW 0,1
switch
M_SSEC_MPPOSW_PSW6_PAXNAM T_STR 6th position switch axis name O -- RW Character string (Axis address of
#1013)
M_SSEC_MPPOSW_PSW6_DOG1 T_FLOATBIN/T_LONG 6th position switch hypothetical dog O -- RW ±99999.999
position 1
M_SSEC_MPPOSW_PSW6_DOG2 T_FLOATBIN/T_LONG 6th position switch hypothetical dog O -- RW ±99999.999
position 2
M_SSEC_MPPOSW_PSW6_CKTYP T_CHAR 6th position switch PSW check method O -- RW 0,1
switch
M_SSEC_MPPOSW_PSW7_PAXNAM T_STR 7th position switch axis name O -- RW Character string (Axis address of
#1013)
M_SSEC_MPPOSW_PSW7_DOG1 T_FLOATBIN/T_LONG 7th position switch hypothetical dog O -- RW ±99999.999
position 1
M_SSEC_MPPOSW_PSW7_DOG2 T_FLOATBIN/T_LONG 7th position switch hypothetical dog O -- RW ±99999.999
position 2
M_SSEC_MPPOSW_PSW7_CKTYP T_CHAR 7th position switch PSW check method O -- RW 0,1
switch
M_SSEC_MPPOSW_PSW8_PAXNAM T_STR 8th position switch axis name O -- RW Character string (Axis address of
#1013)
M_SSEC_MPPOSW_PSW8_DOG1 T_FLOATBIN/T_LONG 8th position switch hypothetical dog O -- RW ±99999.999
position 1
M_SSEC_MPPOSW_PSW8_DOG2 T_FLOATBIN/T_LONG 8th position switch hypothetical dog O -- RW ±99999.999
position 2
M_SSEC_MPPOSW_PSW8_CKTYP T_CHAR 8th position switch PSW check method O -- RW 0,1
switch
M_SSEC_MPPOSW_PSW_EX_NAME(x) T_STR 9th-24th position switch axis name O -- RW Character string (Axis address of
(x=9-) #1013)
M_SSEC_MPPOSW_PSW_EX_DOG1(x) T_FLOATBIN/T_LONG 9th-24th position switch hypothetical O -- RW ±99999.999
dog position 1 (x=9-)

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 115 of 206
inventcom

M_SSEC_MPPOSW_PSW_EX_DOG2(x) T_FLOATBIN/T_LONG 9th-24th position switch hypothetical O -- RW ±99999.999


dog position 2 (x=9-)
M_SSEC_MPPOSW_PSW_EX_CHCK(x) T_CHAR 9th-24th position switch PSW check O -- RW 0,1
method switch (x=9-)

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 116 of 206
inventcom

Power supply monitor


Command Data type Description PS AX RW Range
M_SSEC_MPWS_UNIT_TYP T_STR Drive unit type -- O R
M_SSEC_MPWS_UNIT_NO T_STR Drive unit serial No. -- O R
M_SSEC_MPWS_SW_VER T_STR Software version -- O R
M_SSEC_MPWS_WORK_TIME T_LONG Operation time -- O R
M_SSEC_MPWS_ALM_HIST_TM1 T_LONG Alarm history 1 (Time) -- O R
M_SSEC_MPWS_ALM_HIST_TM2 T_LONG Alarm history 2 (Time) -- O R
M_SSEC_MPWS_ALM_HIST_TM3 T_LONG Alarm history 3 (Time) -- O R
M_SSEC_MPWS_ALM_HIST_TM4 T_LONG Alarm history 4 (Time) -- O R
M_SSEC_MPWS_ALM_HIST_TM5 T_LONG Alarm history 5 (Time) -- O R
M_SSEC_MPWS_ALM_HIST_TM6 T_LONG Alarm history 6 (Time) -- O R
M_SSEC_MPWS_ALM_HIST_TM7 T_LONG Alarm history 7 (Time) -- O R
M_SSEC_MPWS_ALM_HIST_TM8 T_LONG Alarm history 8 (Time) -- O R
M_SSEC_MPWS_ALM_HIST_NO1 T_CHAR Alarm history 1 (Alarm No.) -- O R
M_SSEC_MPWS_ALM_HIST_NO2 T_CHAR Alarm history 2 (Alarm No.) -- O R
M_SSEC_MPWS_ALM_HIST_NO3 T_CHAR Alarm history 3 (Alarm No.) -- O R
M_SSEC_MPWS_ALM_HIST_NO4 T_CHAR Alarm history 4 (Alarm No.) -- O R
M_SSEC_MPWS_ALM_HIST_NO5 T_CHAR Alarm history 5 (Alarm No.) -- O R
M_SSEC_MPWS_ALM_HIST_NO6 T_CHAR Alarm history 6 (Alarm No.) -- O R
M_SSEC_MPWS_ALM_HIST_NO7 T_CHAR Alarm history 7 (Alarm No.) -- O R
M_SSEC_MPWS_ALM_HIST_NO8 T_CHAR Alarm history 8 (Alarm No.) -- O R
M_SSEC_MPWS_MNT1 T_STR Maintenance history (MNT1) -- O R
M_SSEC_MPWS_MNT2 T_STR Maintenance history (MNT2) -- O R
M_SSEC_MPWS_MNT3 T_STR Maintenance history (MNT3) -- O R
M_SSEC_MPWS_MNT4 T_STR Maintenance history (MNT4) -- O R
M_SSEC_MPWS_SYS T_STR /SYS -- O R
M_SSEC_MPWS_DRIVE Connected drive unit -- O W
M_SSEC_MPWS_REC_ENERGY T_LONG Recovered energy -- O R 0 to 999
M_SSEC_MPWS_PWSPLY_VOL T_LONG Power supply voltage -- O R 0 to 999
M_SSEC_MPWS_PNBUS_VOL T_LONG PN bus voltage -- O R 0 to 999
M_SSEC_MPWS_MIN_PNBUS_VOL T_LONG MINPN bus voltage -- O R 0 to 999
M_SSEC_MPWS_MIN_PNBUS_CUR T_LONG Bus current when MINPN -- O R 0 to 999
M_SSEC_MPWS_BUS_CUR T_LONG Bus current -- O R 0 to 999

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 117 of 206
inventcom

M_SSEC_MPWS_MAX_CUR1 T_LONG MAX power current 1 -- O R 0 to 999


M_SSEC_MPWS_MAX_CUR2 T_LONG MAX power current 2 -- O R 0 to 999
M_SSEC_MPWS_MAX_RGN_CUR1 T_LONG MAX regenerative current 1 -- O R 0 to 999
M_SSEC_MPWS_MAX_RGN_CUR2 T_LONG MAX regenerative current 2 -- O R 0 to 999
M_SSEC_MPWS_INSTANT_STOP T_LONG Instantaneous power interrupt -- O R 0 to 9999
M_SSEC_MPWS_ALM_CLR T_CHAR Alarm history clear -- O W 0

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 118 of 206
inventcom

Program execution status


Command Data type Description PS AX RW Range
M_SSEC_PGST_NEST_LEBEL T_CHAR Nest level of sub program in execution O -- R
M_SSEC_PGST_INVLD_STS1 T_CHAR Disabled status: Single block/MST O -- R
complete
M_SSEC_PGST_INVLD_STS2 T_CHAR Disabled status: Feed O -- R
hold/Override/Exact
M_SSEC_PGST_ACT_PROG_PATH T_STR Path of program in execution O -- R
M_SSEC_PGST_ACT_MAIN_O T_STR Main O No. in execution O -- R
M_SSEC_PGST_ACT_MAIN_N T_LONG Main N No. in execution O -- R
M_SSEC_PGST_ACT_MAIN_B T_LONG Main B No. in execution O -- R
M_SSEC_PGST_ACT_SUB_O T_STR Sub O No. in execution O -- R
M_SSEC_PGST_ACT_SUB_N T_LONG Sub N No. in execution O -- R
M_SSEC_PGST_ACT_SUB_B T_LONG Sub B No. in execution O -- R
M_SSEC_PGST_BUFF_PRG_POS T_LONG Display position of buffer display O -- R 0 to
program (The number of bytes from the
program head)
M_SSEC_PGST_RUN_AFTER_SRCH T_UCHAR Auto-start after search not executed -- -- R 0 to 0x0F
M_SSEC_PGST_LST_PROG_PATH T_STR Path of program last executed O -- R
M_SSEC_PGST_LST_MAIN_O T_STR Main O No. of program last executed O -- R
M_SSEC_PGST_LST_MAIN_N T_LONG Main N No. of program last executed O -- R
M_SSEC_PGST_LST_MAIN_B T_LONG Main B No. of program last executed O -- R
M_SSEC_PGST_LST_SUB_O T_STR Sub O No. of program last executed O -- R
M_SSEC_PGST_LST_SUB_N T_LONG Sub N No. of program last executed O -- R
M_SSEC_PGST_LST_SUB_B T_LONG Sub B No. of program last executed O -- R
M_SSEC_PGST_LST_SUB_P T_LONG Sub P No. of program last executed O -- R
M_SSEC_PGST_SRCH_N T_LONG N No. which was searched O -- R -1 to 999999
M_SSEC_PGST_SRCH_B T_LONG B No. which was searched O -- R -1 to 99999

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 119 of 206
inventcom

Program tree
Command Data type Description PS AX RW Range
M_SSEC_TREE_MAIN_DEV T_LONG Name of main device in execution O -- R
M_SSEC_TREE_MAIN_O T_STR Main O No. in execution O -- R
M_SSEC_TREE_MAIN_N T_LONG Main N No. in execution O -- R
M_SSEC_TREE_MAIN_B T_LONG Main B No. in execution O -- R
M_SSEC_TREE_SUB_DEV(x) T_LONG Sub 1 to 10 device name in execution O -- R
(x=1 to 10)
M_SSEC_TREE_SUB_O(x) T_STR Sub 1 to 10 O number in execution O -- R
(x=1 to 10)
M_SSEC_TREE_SUB_N(x) T_LONG Sub 1 to 10 N number in execution O -- R
(x=1 to 10)
M_SSEC_TREE_SUB_B(x) T_LONG Sub 1 to 10 B number in execution O -- R
(x=1 to 10)
M_SSEC_TREE_SUB_L(x) T_LONG Sub 1 to 10 number of times of O -- R
repetition (x=1 to 10)
M_SSEC_TREE_PROG_LIST T_BUFF Program tree information in execution O -- R
(ONB) displayed program name
M_SSEC_TREE_PROG_LIST2 T_BUFF Program tree information in execution O -- R
(ONB) internal program name
M_SSEC_TREE_PROG_LIST_PATH(x) T_STR Program path information (X=1 to 2) O -- R
*Prohibited to be used from HMI

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 120 of 206
inventcom

Program tree for graphic check


Command Data type Description PS AX RW Range
M_SSEC_TREEGC_MAIN_O T_STR Main O number in execution for check O -- R
M_SSEC_TREEGC_MAIN_N T_LONG Main N number in execution for check O -- R
M_SSEC_TREEGC_MAIN_B T_LONG Main B number in execution for check O -- R

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 121 of 206
inventcom

Rererence position return parameter


Command Data type Description PS AX RW Range
M_SSEC_MPREFR_G28RAP T_FLOATBIN/T_DOUBLE G28 rapid traverse rate -- O RW 1 to 999999
M_SSEC_MPREFR_G28CRP T_FLOATBIN/T_DOUBLE G28 approach speed -- O RW 1 to 60000
M_SSEC_MPREFR_G28 T_FLOATBIN/T_DOUBLE Reference position shift amount -- O RW 0 to 65535
M_SSEC_MPREFR_GRSFT T_FLOATBIN/T_DOUBLE Grid mask amount -- O RW 0 to 65535
M_SSEC_MPREFR_GRSPC T_FLOATBIN/T_DOUBLE Grid interval -- O RW -32767 to 999
M_SSEC_MPREFR_DIA T_LONG Reference position direction (-) -- O RW 0,1
M_SSEC_MPREFR_NOREF T_LONG Axis with no reference position -- O RW 0,1
M_SSEC_MPREFR_NOCHK T_LONG Whether reference position return is -- O RW 0,1
completed or not checked
M_SSEC_MPREFR_ZP_NO T_CHAR Z-phase type reference position return -- O RW 0 to 4
spindle encoder No. (zp_no)
M_SSEC_MPREFR_RFPOFS T_FLOATBIN/T_DOUBLE Reference position offset amount -- O RW ±99999.999
M_SSEC_MPREFR_SRCHMAX T_FLOATBIN/T_DOUBLE Reference position maximum scanning -- O RW 0.000 to 99999.999
distance
M_SSEC_MPREFR_SLV_ADJUST T_FLOATBIN/T_DOUBLE Reference position adjustment amount -- O RW ±99999.999
M_SSEC_MPREFR_REF1 T_FLOATBIN/T_DOUBLE #1 Reference position -- O RW ±99999.999
M_SSEC_MPREFR_REF2 T_FLOATBIN/T_DOUBLE #2 Reference position -- O RW ±99999.999
M_SSEC_MPREFR_REF3 T_FLOATBIN/T_DOUBLE #3 Reference position -- O RW ±99999.999
M_SSEC_MPREFR_REF4 T_FLOATBIN/T_DOUBLE #4 Reference position -- O RW ±99999.999

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 122 of 206
inventcom

Rotary axis configuration parameter


Command Data type Description PS AX RW Range
M_SSEC_MPROTAX_RECTANGULAR_AX_I T_CHAR Orthogonal coordinate horizontal axis O -- RW A,B,C,U,V,W,X,Y,Z
name
M_SSEC_MPROTAX_RECTANGULAR_AX_J T_CHAR Orthogonal coordinate vertical axis O -- RW A,B,C,U,V,W,X,Y,Z
name
M_SSEC_MPROTAX_RECTANGULAR_AX_K T_CHAR Orthogonal coordinate height axis O -- RW A,B,C,U,V,W,X,Y,Z
name
M_SSEC_MPROTAX_G92_COORD T_CHAR Origin zero set coordinate selection O -- RW 0,1
M_SSEC_MPROTAX_NO_TIP_POSITION T_CHAR Tool handle feed function selection O -- RW 0,1
M_SSEC_MPROTAX_NO_ABS T_CHAR Selection of tool axis travel amount O -- RW 0,1
display at manual ABS switch ON/OFF
M_SSEC_MPROTAX_SINGU_PASS_TYPE T_CHAR Singular point passage type O -- RW 0,1
M_SSEC_MPROTAX_SINGU_CHK_HOLD T_FLOATBIN Near singular judgment angle O -- RW 0.000 to 5.000
M_SSEC_MPROTAX_SLCT_PRG_COORD T_CHAR Near singular judgment angle O -- RW 0,1
M_SSEC_MPROTAX_IJK_VEC_MR T_CHAR Posture vector mirror image selection O -- RW 0,1
M_SSEC_MPROTAX_SLCT_INT_MODE T_CHAR Tool centre point control interpolation O -- RW 0,1
type select
M_SSEC_MPROTAX_SLCT_STD_POS T_CHAR Rotary axis basic position selection O -- RW 0,1
M_SSEC_MPROTAX_MCHN_SPD_CTRL T_CHAR Machine speed fluctuation suppression O -- RW 0,1
M_SSEC_MPROTAX_SELECT_ROT_AX_T1 T_CHAR Rotary axis selection of base-side tool O -- RW 0 to 3,12,13,21,23,31,32
axis
M_SSEC_MPROTAX_TILT_ANG_T1 T_FLOATBIN/T_LONG Inclination angle of base-side tool axis O -- RW ±359.999
M_SSEC_MPROTAX_ROT_AX_NAME_T1 T_CHAR Rotary axis name of base-side tool axis O -- RW 0,A,B,C,U,V,W,X,Y,Z
M_SSEC_MPROTAX_DIR_ROT_AX_T1 T_CHAR Rotation direction of base-side tool axis O -- RW 0,1
M_SSEC_MPROTAX_CENTER_OFS_T1H T_FLOATBIN/T_LONG Horizontal axis rotation center offset of O -- RW ±99999.999
base-side tool axis
M_SSEC_MPROTAX_CENTER_OFS_T1V T_FLOATBIN/T_LONG Vertical axis rotation center offset of O -- RW ±99999.999
base-side tool axis
M_SSEC_MPROTAX_CENTER_OFS_T1T T_FLOATBIN/T_LONG Height axis rotation center offset of O -- RW ±99999.999
base-side tool axis
M_SSEC_MPROTAX_CENTER_ERR_T1H T_FLOATBIN/T_LONG Horizontal axis rotation center error O -- RW ±99999.999
compensation amount of base-side tool
axis

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 123 of 206
inventcom

M_SSEC_MPROTAX_CENTER_ERR_T1V T_FLOATBIN/T_LONG Vertical axis rotation center error O -- RW ±99999.999


compensation amount of base-side tool
axis
M_SSEC_MPROTAX_SELECT_ROT_AX_T2 T_CHAR Rotary axis selection of tool-side tool O -- RW 0 to 3,12,13,21,23,31,32
axis
M_SSEC_MPROTAX_TILT_ANG_T2 T_FLOATBIN/T_LONG Inclination angle of tool-side tool axis O -- RW ±359.999
M_SSEC_MPROTAX_ROT_AX_NAME_T2 T_CHAR Rotary axis name of tool-side tool axis O -- RW 0,A,B,C,U,V,W,X,Y,Z
M_SSEC_MPROTAX_DIR_ROT_AX_T2 T_CHAR Rotation direction of tool-side tool axis O -- RW 0,1
M_SSEC_MPROTAX_CENTER_OFS_T2H T_FLOATBIN/T_LONG Horizontal axis rotation center offset of O -- RW ±99999.999
tool-side tool axis
M_SSEC_MPROTAX_CENTER_OFS_T2V T_FLOATBIN/T_LONG Vertical axis rotation center offset of O -- RW ±99999.999
tool-side tool axis
M_SSEC_MPROTAX_CENTER_OFS_T2T T_FLOATBIN/T_LONG Height axis rotation center offset of O -- RW ±99999.999
tool-side tool axis
M_SSEC_MPROTAX_CENTER_ERR_T2H T_FLOATBIN/T_LONG Horizontal axis rotation center error O -- RW ±99999.999
compensation amount of tool-side tool
axis
M_SSEC_MPROTAX_CENTER_ERR_T2V T_FLOATBIN/T_LONG Vertical axis rotation center error O -- RW ±99999.999
compensation amount of tool-side tool
axis
M_SSEC_MPROTAX_SELECT_ROT_AX_W1 T_CHAR Rotary axis selection of tool-side table O -- RW 0 to 3,12,13,21,23,31,32
axis
M_SSEC_MPROTAX_TILT_ANG_W1 T_FLOATBIN/T_LONG Inclination angle of tool-side table axis O -- RW ±359.999
M_SSEC_MPROTAX_ROT_AX_NAME_W1 T_CHAR Rotary axis name of tool-side table axis O -- RW 0,A,B,C,U,V,W,X,Y,Z
M_SSEC_MPROTAX_DIR_ROT_AX_W1 T_CHAR Rotation direction of tool-side table axis O -- RW 0,1
M_SSEC_MPROTAX_CENTER_OFS_W1H T_FLOATBIN/T_LONG Horizontal axis rotation center offset of O -- RW ±99999.999
tool-side table axis
M_SSEC_MPROTAX_CENTER_OFS_W1V T_FLOATBIN/T_LONG Vertical axis rotation center offset of O -- RW ±99999.999
tool-side table axis
M_SSEC_MPROTAX_CENTER_OFS_W1T T_FLOATBIN/T_LONG Height axis rotation center offset of O -- RW ±99999.999
tool-side table axis
M_SSEC_MPROTAX_CENTER_ERR_W1H T_FLOATBIN/T_LONG Horizontal axis rotation center error O -- RW ±99999.999
compensation amount of tool-side table
axis
M_SSEC_MPROTAX_CENTER_ERR_W1V T_FLOATBIN/T_LONG Vertical axis rotation center error O -- RW ±99999.999
compensation amount of tool-side table
axis

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 124 of 206
inventcom

M_SSEC_MPROTAX_SELECT_ROT_AX_W2 T_CHAR Rotary axis selection of workpiece-side O -- RW 0 to 3,12,13,21,23,31,32


table axis
M_SSEC_MPROTAX_TILT_ANG_W2 T_FLOATBIN/T_LONG Inclination angle of workpiece-side O -- RW ±359.999
table axis
M_SSEC_MPROTAX_ROT_AX_NAME_W2 T_CHAR Rotary axis name of workpiece-side O -- RW 0,A,B,C,U,V,W,X,Y,Z
table axis
M_SSEC_MPROTAX_DIR_ROT_AX_W2 T_CHAR Rotation direction of workpiece-side O -- RW 0,1
table axis
M_SSEC_MPROTAX_CENTER_OFS_W2H T_FLOATBIN/T_LONG Horizontal axis rotation center offset of O -- RW ±99999.999
workpiece-side table axis
M_SSEC_MPROTAX_CENTER_OFS_W2V T_FLOATBIN/T_LONG Vertical axis rotation center offset of O -- RW ±99999.999
workpiece-side table axis
M_SSEC_MPROTAX_CENTER_OFS_W2T T_FLOATBIN/T_LONG Height axis rotation center offset of O -- RW ±99999.999
workpiece-side table axis
M_SSEC_MPROTAX_CENTER_ERR_W2H T_FLOATBIN/T_LONG Horizontal axis rotation center error O -- RW ±99999.999
compensation amount of workpiece-
side table axis
M_SSEC_MPROTAX_CENTER_ERR_W2V T_FLOATBIN/T_LONG Vertical axis rotation center error O -- RW ±99999.999
compensation amount of workpiece-
side table axis

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 125 of 206
inventcom

Sampling parameter
Command Data type Description PS AX RW Range
M_SSEC_SMP_PRM_TRIGGER T_SHORT Sampling trigger -- -- RW 0,1,9
M_SSEC_SMP_PRM_SAMP_RATE T_SHORT Sampling cycle -- -- RW 0x01 to 0xFF
M_SSEC_SMP_PRM_SAMP_NOS T_SHORT The number of pieces of sampling data -- -- RW 0 to 8
M_SSEC_SMP_PRM_BUFF_ADDR T_LONG Sampling data buffer address -- -- RW 0 to Address
M_SSEC_SMP_PRM_BUFF_SIZE T_LONG Sampling data buffer size -- -- RW 0 to Size
M_SSEC_SMP_PRM_SAMP_ADDR1 T_LONG Sampling address #1 (Compatible with -- -- RW 0 to Address
M625)
M_SSEC_SMP_PRM_SAMP_ADDR2 T_LONG Sampling address #2 (Compatible with -- -- RW 0 to Address
M625)
M_SSEC_SMP_PRM_SAMP_ADDR3 T_LONG Sampling address #3 (Compatible with -- -- RW 0 to Address
M625)
M_SSEC_SMP_PRM_SAMP_ADDR4 T_LONG Sampling address #4 (Compatible with -- -- RW 0 to Address
M625)
M_SSEC_SMP_PRM_SAMP_ADDR5 T_LONG Sampling address #5 (Compatible with -- -- RW 0 to Address
M625)
M_SSEC_SMP_PRM_SAMP_ADDR6 T_LONG Sampling address #6 (Compatible with -- -- RW 0 to Address
M625)
M_SSEC_SMP_PRM_SAMP_ADDR7 T_LONG Sampling address #7 (Compatible with -- -- RW 0 to Address
M625)
M_SSEC_SMP_PRM_SAMP_ADDR8 T_LONG Sampling address #8 (Compatible with -- -- RW 0 to Address
M625)
M_SSEC_SMP_PRM_SAMP_EX_ADDR1 T_LONG Sampling address #1 -- -- RW 0 to Address or Symbol (Within 16
letters)
M_SSEC_SMP_PRM_SAMP_EX_ADDR2 T_LONG Sampling address #2 -- -- RW 0 to Address or Symbol (Within 16
letters)
M_SSEC_SMP_PRM_SAMP_EX_ADDR3 T_LONG Sampling address #3 -- -- RW 0 to Address or Symbol (Within 16
letters)
M_SSEC_SMP_PRM_SAMP_EX_ADDR4 T_LONG Sampling address #4 -- -- RW 0 to Address or Symbol (Within 16
letters)
M_SSEC_SMP_PRM_SAMP_EX_ADDR5 T_LONG Sampling address #5 -- -- RW 0 to Address or Symbol (Within 16
letters)
M_SSEC_SMP_PRM_SAMP_EX_ADDR6 T_LONG Sampling address #6 -- -- RW 0 to Address or Symbol (Within 16
letters)

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 126 of 206
inventcom

M_SSEC_SMP_PRM_SAMP_EX_ADDR7 T_LONG Sampling address #7 -- -- RW 0 to Address or Symbol (Within 16


letters)
M_SSEC_SMP_PRM_SAMP_EX_ADDR8 T_LONG Sampling address #8 -- -- RW 0 to Address or Symbol (Within 16
letters)
M_SSEC_SMP_PRM_SAMP_AT_ADDR1 T_LONG Sampling address #1 for AT -- -- W 0 to 0xFFFFFFFF(Special data)
M_SSEC_SMP_PRM_SAMP_AT_ADDR2 T_LONG Sampling address #2 for AT -- -- W 0 to 0xFFFFFFFF(Special data)
M_SSEC_SMP_PRM_SAMP_AT_ADDR3 T_LONG Sampling address #3 for AT -- -- W 0 to 0xFFFFFFFF(Special data)
M_SSEC_SMP_PRM_SAMP_AT_ADDR4 T_LONG Sampling address #4 for AT -- -- W 0 to 0xFFFFFFFF(Special data)
M_SSEC_SMP_PRM_SAMP_AT_ADDR5 T_LONG Sampling address #5 for AT -- -- W 0 to 0xFFFFFFFF(Special data)
M_SSEC_SMP_PRM_SAMP_AT_ADDR6 T_LONG Sampling address #6 for AT -- -- W 0 to 0xFFFFFFFF(Special data)
M_SSEC_SMP_PRM_SAMP_AT_ADDR7 T_LONG Sampling address #7 for AT -- -- W 0 to 0xFFFFFFFF(Special data)
M_SSEC_SMP_PRM_SAMP_AT_ADDR8 T_LONG Sampling address #8 for AT -- -- W 0 to 0xFFFFFFFF(Special data)
M_SSEC_SMP_PRM_TRGMOD T_LONG Buffer designation (0: Internal memory, -- -- RW 0,1(1 is available only for M65V)
1: Cassette memory)
M_SSEC_SMP_PRM_BUFF_CAP T_LONG Buffer capacity (1024*(Setting value+1) -- -- RW 0 to n
byte)
M_SSEC_SMP_PRM_START_COND T_LONG Start condition -- -- RW 0 to 4
M_SSEC_SMP_PRM_PROC_FORM T_LONG Process format (0: 1-shot, 1: Repeat, 2: -- -- RW 0 to 2
Ring buffer)
M_SSEC_SMP_PRM_END_COND T_LONG End condition -- -- RW 0 to 4
M_SSEC_SMP_PRM_VAR_NUM T_LONG Variable No. (0: #1299, Other than 0: -- -- RW 0 to 999
Common variable)
M_SSEC_SMP_PRM_PLC_DEV T_STR PLC device -- -- RW Within 6 letters
M_SSEC_SMP_PRM_COND_ADDR T_LONG Condition address -- -- RW long range
M_SSEC_SMP_PRM_COND_DATA T_LONG Condition data -- -- RW long range
M_SSEC_SMP_PRM_COND_MASK T_LONG Condition data mask -- -- RW long range
M_SSEC_SMP_PRM_SAMP_OUT T_LONG Sampling data output type -- -- RW 0 to 2
M_SSEC_SMP_PRM_SAMP_MAX_DATA T_LONG The maximum number of pieces of -- -- R 0 to 1310720
sampling data
M_SSEC_SMP_PRM_SAMPDAT_UNIT1 T_STR Sampling data output unit #1 -- -- RW 0(Blank),B to E,S
M_SSEC_SMP_PRM_SAMPDAT_UNIT2 T_STR Sampling data output unit #2 -- -- RW 0(Blank),B to E,S
M_SSEC_SMP_PRM_SAMPDAT_UNIT3 T_STR Sampling data output unit #3 -- -- RW 0(Blank),B to E,S
M_SSEC_SMP_PRM_SAMPDAT_UNIT4 T_STR Sampling data output unit #4 -- -- RW 0(Blank),B to E,S
M_SSEC_SMP_PRM_SAMPDAT_UNIT5 T_STR Sampling data output unit #5 -- -- RW 0(Blank),B to E,S
M_SSEC_SMP_PRM_SAMPDAT_UNIT6 T_STR Sampling data output unit #6 -- -- RW 0(Blank),B to E,S
M_SSEC_SMP_PRM_SAMPDAT_UNIT7 T_STR Sampling data output unit #7 -- -- RW 0(Blank),B to E,S

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 127 of 206
inventcom

M_SSEC_SMP_PRM_SAMPDAT_UNIT8 T_STR Sampling data output unit #8 -- -- RW 0(Blank),B to E,S


M_SSEC_SMP_PRM_AT_SMP_STS T_LONG Sampling status (For auto tuning) -- -- R --
M_SSEC_SMP_PRM_AT_DELAY T_LONG Sampling delay time (For auto tuning) -- -- RW 0 to 0x7FFFFFFF
M_SSEC_SMP_PRM_AT_START_REQ T_LONG Cycle start request (For auto tuning) -- -- W 0 to 0xFFFFFFFF
M_SSEC_SMP_PRM_AT_START_LOCK T_LONG Cycle start lock (For auto tuning) -- -- RW 0 to 1
M_SSEC_SMP_PRM_AT_SAMP_NOS T_LONG The number of pieces of sampling data -- -- R --
(For auto tuning)
M_SSEC_SMP_PRM_AT_OP_CHK T_LONG OP check information (For auto tuning) -- -- RW 0 to 2

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 128 of 206
inventcom

Servo monitor
Command Data type Description PS AX RW Range
M_SSEC_MSV_GAIN T_LONG Gain -- O R
M_SSEC_MSV_DROOP T_LONG Droop -- O R
M_SSEC_MSV_REV_SPD T_SHORT Rotation speed -- O R
M_SSEC_MSV_MAX_CUR1 T_SHORT MAX current 1 -- O R
M_SSEC_MSV_MAX_CUR2 T_SHORT MAX current 2 -- O R
M_SSEC_MSV_OVER_LOAD T_SHORT Overload -- O R
M_SSEC_MSV_OVER_REG T_SHORT Regenerative load -- O R
M_SSEC_MSV_AMP_DISP T_CHAR Drive unit display -- O R
M_SSEC_MSV_ALARM1 T_STR Alarm 1 -- O R
M_SSEC_MSV_ALARM2 T_STR Alarm 2 -- O R
M_SSEC_MSV_ALARM3 T_STR Alarm 3 -- O R
M_SSEC_MSV_ALARM4 T_STR Alarm 4 -- O R
M_SSEC_MSV_CYC_CNT T_LONG Cycle counter -- O R
M_SSEC_MSV_GRDSP T_FLOATBIN/T_LONG Grid interval -- O R
M_SSEC_MSV_GRID T_FLOATBIN/T_LONG Grid amount -- O R
M_SSEC_MSV_MAC_POS T_FLOATBIN/T_LONG Machine position -- O R
M_SSEC_MSV_MOT_POS T_FLOATBIN/T_LONG Motor end FB -- O R
M_SSEC_MSV_SCA_POS T_FLOATBIN/T_LONG Machine end FB -- O R
M_SSEC_MSV_FB_ERROR T_LONG FB error -- O R
M_SSEC_MSV_DFB_COMP T_LONG DFB compensation amount -- O R
M_SSEC_MSV_DISTANCE T_FLOATBIN/T_LONG Remaining command -- O R
M_SSEC_MSV_POSITION2 T_FLOATBIN/T_LONG Current value (2) -- O R
M_SSEC_MSV_MANUAL_IT T_FLOATBIN/T_LONG Manual interruption amount -- O R
M_SSEC_MSV_ABS_SYS T_STR Detection system -- O R
M_SSEC_MSV_ABS_PON_POS T_FLOATBIN/T_LONG Power ON position -- O R
M_SSEC_MSV_ABS_POF_POS T_FLOATBIN/T_LONG Power OFF position -- O R
M_SSEC_MSV_ABS_MAC_POS T_FLOATBIN/T_LONG Current position -- O R
M_SSEC_MSV_R0 T_SHORT R0 (Revolution counter in setting -- O R
reference position)
M_SSEC_MSV_P0 T_LONG P0 (Position within one revolution in -- O R
setting reference position)

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 129 of 206
inventcom

M_SSEC_MSV_E0 T_SHORT E0 (Absolute position error in setting -- O R


reference position)
M_SSEC_MSV_RN T_SHORT Rn (Revolution counter) -- O R
M_SSEC_MSV_PN T_LONG Pn (Position within one revolution) -- O R
M_SSEC_MSV_EN T_SHORT En (Absolute position error at power -- O R
OFF)
M_SSEC_MSV_ABS0 T_LONG ABS0 (Absolute position base counter) -- O R
M_SSEC_MSV_ABSN T_LONG ABSn (Absolute position counter) -- O R
M_SSEC_MSV_MPOS T_SHORT MPOS (Initial offset amount) -- O R
M_SSEC_MSV_UNIT_TYP T_STR Drive unit type -- O R
M_SSEC_MSV_UNIT_NO T_STR Drive unit serial No. -- O R
M_SSEC_MSV_SW_VER T_STR Software version -- O R
M_SSEC_MSV_CNTROL T_STR Control method -- O R
M_SSEC_MSV_MOT_DT T_STR Motor end detector -- O R
M_SSEC_MSV_MAC_DT T_STR Machine end detector -- O R
M_SSEC_MSV_MOTOR T_STR Motor type -- O R
M_SSEC_MSV_WORK_TIME T_LONG Operation time -- O RW 0x00 to 0xFF
M_SSEC_MSV_ALM_HIST_TM1 T_LONG Alarm history 1 (Time) -- O RW 0x00 to 0xFF
M_SSEC_MSV_ALM_HIST_TM2 T_LONG Alarm history 2 (Time) -- O RW 0x00 to 0xFF
M_SSEC_MSV_ALM_HIST_TM3 T_LONG Alarm history 3 (Time) -- O RW 0x00 to 0xFF
M_SSEC_MSV_ALM_HIST_TM4 T_LONG Alarm history 4 (Time) -- O RW 0x00 to 0xFF
M_SSEC_MSV_ALM_HIST_TM5 T_LONG Alarm history 5 (Time) -- O RW 0x00 to 0xFF
M_SSEC_MSV_ALM_HIST_TM6 T_LONG Alarm history 6 (Time) -- O RW 0x00 to 0xFF
M_SSEC_MSV_ALM_HIST_TM7 T_LONG Alarm history 7 (Time) -- O RW 0x00 to 0xFF
M_SSEC_MSV_ALM_HIST_TM8 T_LONG Alarm history 8 (Time) -- O RW 0x00 to 0xFF
M_SSEC_MSV_ALM_HIST_NO1 T_CHAR Alarm history 1 (Alarm No.) -- O RW 0x00 to 0xFF
M_SSEC_MSV_ALM_HIST_NO2 T_CHAR Alarm history 2 (Alarm No.) -- O RW 0x00 to 0xFF
M_SSEC_MSV_ALM_HIST_NO3 T_CHAR Alarm history 3 (Alarm No.) -- O RW 0x00 to 0xFF
M_SSEC_MSV_ALM_HIST_NO4 T_CHAR Alarm history 4 (Alarm No.) -- O RW 0x00 to 0xFF
M_SSEC_MSV_ALM_HIST_NO5 T_CHAR Alarm history 5 (Alarm No.) -- O RW 0x00 to 0xFF
M_SSEC_MSV_ALM_HIST_NO6 T_CHAR Alarm history 6 (Alarm No.) -- O RW 0x00 to 0xFF
M_SSEC_MSV_ALM_HIST_NO7 T_CHAR Alarm history 7 (Alarm No.) -- O RW 0x00 to 0xFF
M_SSEC_MSV_ALM_HIST_NO8 T_CHAR Alarm history 8 (Alarm No.) -- O RW 0x00 to 0xFF
M_SSEC_MSV_MNT1 T_STR Maintenance history (MNT1) -- O R
M_SSEC_MSV_MNT2 T_STR Maintenance history (MNT2) -- O R
M_SSEC_MSV_MNT3 T_STR Maintenance history (MNT3) -- O R

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 130 of 206
inventcom

M_SSEC_MSV_MNT4 T_STR Maintenance history (MNT4) -- O R


M_SSEC_MSV_SYS T_STR /SYS -- O R
M_SSEC_MSV_ABS_POS T_FLOATBIN/T_LONG Absolute position (Drive unit output) -- O R --
M_SSEC_MSV_MACECOMP T_FLOATBIN/T_LONG Machine error compensation amount -- O R --
(Drive unit output)
M_SSEC_MSV_CMD1L T_STR/T_LONG Control input 1L -- O R --
M_SSEC_MSV_CMD1H T_STR/T_LONG Control input 1H -- O R --
M_SSEC_MSV_CMD2L T_STR/T_LONG Control input 2L -- O R --
M_SSEC_MSV_CMD2H T_STR/T_LONG Control input 2H -- O R --
M_SSEC_MSV_CMD3L T_STR/T_LONG Control input 3L -- O R --
M_SSEC_MSV_CMD3H T_STR/T_LONG Control input 3H -- O R --
M_SSEC_MSV_CMD4L T_STR/T_LONG Control input 4L -- O R --
M_SSEC_MSV_CMD4H T_STR/T_LONG Control input 4H -- O R --
M_SSEC_MSV_CMD5L T_STR/T_LONG Control input 5L -- O R --
M_SSEC_MSV_CMD5H T_STR/T_LONG Control input 5H -- O R --
M_SSEC_MSV_CMD6L T_STR/T_LONG Control input 6L -- O R --
M_SSEC_MSV_CMD6H T_STR/T_LONG Control input 6H -- O R --
M_SSEC_MSV_STS1L T_STR/T_LONG Control output 1L -- O R --
M_SSEC_MSV_STS1H T_STR/T_LONG Control output 1H -- O R --
M_SSEC_MSV_STS2L T_STR/T_LONG Control output 2L -- O R --
M_SSEC_MSV_STS2H T_STR/T_LONG Control output 2H -- O R --
M_SSEC_MSV_STS3L T_STR/T_LONG Control output 3L -- O R --
M_SSEC_MSV_STS3H T_STR/T_LONG Control output 3H -- O R --
M_SSEC_MSV_STS4L T_STR/T_LONG Control output 4L -- O R --
M_SSEC_MSV_STS4H T_STR/T_LONG Control output 4H -- O R --
M_SSEC_MSV_STS5L T_STR/T_LONG Control output 5L -- O R --
M_SSEC_MSV_STS5H T_STR/T_LONG Control output 5H -- O R --
M_SSEC_MSV_STS6L T_STR/T_LONG Control output 6L -- O R --
M_SSEC_MSV_STS6H T_STR/T_LONG Control output 6H -- O R --
M_SSEC_MSV_ALM_CLR T_CHAR Alarm history clear -- O W 0
M_SSEC_MSV_FEED T_LONG Feedrate -- O R
M_SSEC_MSV_MAX_CUR3 T_SHORT MAX current 3 -- O R
M_SSEC_MSV_EST_DTORQ T_SHORT Estimated disturbance torque -- O R
M_SSEC_MSV_MAX_DTORQ T_SHORT MAX disturbance torque -- O R
M_SSEC_MSV_LOAD_INER T_SHORT Load inertia ratio -- O R
M_SSEC_MSV_AFLT_FREQ T_SHORT AFLT frequency -- O R

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 131 of 206
inventcom

M_SSEC_MSV_AFLT_GAIN T_SHORT AFLT gain -- O R


M_SSEC_MSV_MOT_DT_NO T_STR Serial No. of motor end encoder -- O R
M_SSEC_MSV_MAC_DT_NO T_STR Serial No. of machine end encoder -- O R
M_SSEC_MSV_STL_CNV_NUM T_SHORT Stall rating conversion constant -- O R
M_SSEC_MSV_SCA_POS2 T_FLOATBIN/T_LONG Machine end FB (Rotary axis round up) -- O R
M_SSEC_MSV_AUX_CUR_STN T_STR/T_SHORT Auxiliary axis current station No. - O R
M_SSEC_MSV_AUX_MAC_POS T_STR/T_LONG Auxiliary axis current position - O R
M_SSEC_MSV_AUX_INST_STN T_STR/T_SHORT Auxiliary axis target station No. - O R
M_SSEC_MSV_AUX_INST_POS T_STR/T_LONG Auxiliary axis command position - O R
M_SSEC_MSV_ALM_NO(x) T_CHAR Alarm No. (x=1 to 32) -- O R 00 to FF
M_SSEC_MSV_ALM_TIMES(x) T_LONG The number of times of alarm (x=1 to -- O RW (Setting is only 0)
32)
M_SSEC_MSV_DA_ADDRESS1 T_LONG DA address 1 -- O R 0000 to FFFF
M_SSEC_MSV_DA_OUTPUT1 T_LONG DA output 1 -- O R
M_SSEC_MSV_DA_ADDRESS2 T_LONG DA address 2 -- O R 0000 to FFFF
M_SSEC_MSV_DA_OUTPUT2 T_LONG DA output 2 -- O R
M_SSEC_MSV_ALM_TIMES_CLR T_CHAR Clear all the number of times of alarms -- O W 0

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 132 of 206
inventcom

Servo parameter
Command Data type Description PS AX RW Range
M_SSEC_MPSV_SV001 T_SHORT SV01: Motor side gear ratio -- O RW -32768 to 32767
M_SSEC_MPSV_SV002 T_SHORT SV02: Machine side gear ratio -- O RW -32768 to 32767
M_SSEC_MPSV_SV003 T_SHORT SV03: Position loop gain 1 -- O RW -32768 to 32767
M_SSEC_MPSV_SV004 T_SHORT SV04: Position loop gain 2 -- O RW -32768 to 32767
M_SSEC_MPSV_SV005 T_SHORT SV05: Speed loop gain 1 -- O RW -32768 to 32767
M_SSEC_MPSV_SV006 T_SHORT SV06: Speed loop gain 2 -- O RW -32768 to 32767
M_SSEC_MPSV_SV007 T_SHORT SV07: Speed loop delay compensation -- O RW -32768 to 32767
M_SSEC_MPSV_SV008 T_SHORT SV08: Speed loop lead compensation -- O RW -32768 to 32767
M_SSEC_MPSV_SV009 T_SHORT SV09: Current loop q axis lead -- O RW -32768 to 32767
compensation
M_SSEC_MPSV_SV010 T_SHORT SV10: Current loop d axis lead -- O RW -32768 to 32767
compensation
M_SSEC_MPSV_SV011 T_SHORT SV11: Current loop q axis gain -- O RW -32768 to 32767
M_SSEC_MPSV_SV012 T_SHORT SV12: Current loop d axis gain -- O RW -32768 to 32767
M_SSEC_MPSV_SV013 T_SHORT SV13: Current limit value 1 -- O RW -32768 to 32767
M_SSEC_MPSV_SV014 T_SHORT SV14: Current limit value 2 -- O RW -32768 to 32767
M_SSEC_MPSV_SV015 T_SHORT SV15: Acceleration rate feed forward -- O RW -32768 to 32767
gain
M_SSEC_MPSV_SV016 T_SHORT SV16: Lost motion compensation gain -- O RW -32768 to 32767
1
M_SSEC_MPSV_SV017 T_SHORT SV17: Servo system specification -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSV_SV018 T_SHORT SV18: Ball screw pitch -- O RW -32768 to 32767
M_SSEC_MPSV_SV019 T_SHORT SV19: Position detector resolution -- O RW 0 to 65535
M_SSEC_MPSV_SV020 T_SHORT SV20: Speed detector resolution -- O RW -32768 to 32767
M_SSEC_MPSV_SV021 T_SHORT SV21: Overload detection time -- O RW -32768 to 32767
constant
M_SSEC_MPSV_SV022 T_SHORT SV22: Overload detection time level -- O RW -32768 to 32767
M_SSEC_MPSV_SV023 T_SHORT SV23: Excessive error value 1 -- O RW -32768 to 32767
M_SSEC_MPSV_SV024 T_SHORT SV24: In-position width -- O RW -32768 to 32767
M_SSEC_MPSV_SV025 T_SHORT SV25: Motor type -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSV_SV026 T_SHORT SV26: Excessive error value 2 (During -- O RW -32768 to 32767
servo OFF)
M_SSEC_MPSV_SV027 T_SHORT SV27: Servo function 1 -- O RW 0x0000 to 0xFFFF

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 133 of 206
inventcom

M_SSEC_MPSV_SV028 T_SHORT SV28: Not used -- O RW -32768 to 32767


M_SSEC_MPSV_SV029 T_SHORT SV29: Not used -- O RW -32768 to 32767
M_SSEC_MPSV_SV030 T_SHORT SV30: Not used -- O RW -32768 to 32767
M_SSEC_MPSV_SV031 T_SHORT SV31: Overshooting compensation gain -- O RW -32768 to 32767
1
M_SSEC_MPSV_SV032 T_SHORT SV32: Torque offset compensation gain -- O RW -32768 to 32767
M_SSEC_MPSV_SV033 T_SHORT SV33: Servo function 2 -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSV_SV034 T_SHORT SV34: Servo function 3 -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSV_SV035 T_SHORT SV35: Servo function 4 -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSV_SV036 T_SHORT SV36: Power supply type -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSV_SV037 T_SHORT SV37: Motor conversion inertia amount -- O RW -32768 to 32767
M_SSEC_MPSV_SV038 T_SHORT SV38: Machine resonance suppression -- O RW -32768 to 32767
filter frequency
M_SSEC_MPSV_SV039 T_SHORT SV39: Lost motion compensation -- O RW -32768 to 32767
timing
M_SSEC_MPSV_SV040 T_SHORT SV40: Lost motion compensation non- -- O RW -32768 to 32767
sensitive band (Lower 8bits)
M_SSEC_MPSV_SV041 T_SHORT SV41: Lost motion compensation gain -- O RW -32768 to 32767
2
M_SSEC_MPSV_SV042 T_SHORT SV42: Overshooting compensation gain -- O RW -32768 to 32767
2
M_SSEC_MPSV_SV043 T_SHORT SV43: Observer 1 -- O RW -32768 to 32767
M_SSEC_MPSV_SV044 T_SHORT SV44: Observer 2 -- O RW -32768 to 32767
M_SSEC_MPSV_SV045 T_SHORT SV45: Not used -- O RW -32768 to 32767
M_SSEC_MPSV_SV046 T_SHORT SV46: Not used -- O RW -32768 to 32767
M_SSEC_MPSV_SV047 T_SHORT SV47: Inductive voltage compensation -- O RW -32768 to 32767
M_SSEC_MPSV_SV048 T_SHORT SV48: Vertical axis drop prevention -- O RW -32768 to 32767
brake delay time
M_SSEC_MPSV_SV049 T_SHORT SV49: Position loop gain 1 in spindle -- O RW -32768 to 32767
synchronous control
M_SSEC_MPSV_SV050 T_SHORT SV50: Position loop gain 2 in spindle -- O RW -32768 to 32767
synchronous control
M_SSEC_MPSV_SV051 T_SHORT SV51: Not used -- O RW -32768 to 32767
M_SSEC_MPSV_SV052 T_SHORT SV52: Not used -- O RW -32768 to 32767
M_SSEC_MPSV_SV053 T_SHORT SV53: Excessive error value 3 error -- O RW -32768 to 32767
M_SSEC_MPSV_SV054 T_SHORT SV54: Not used -- O RW -32768 to 32767

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 134 of 206
inventcom

M_SSEC_MPSV_SV055 T_SHORT SV55: Not used -- O RW -32768 to 32767


M_SSEC_MPSV_SV056 T_SHORT SV56: Drop prevention deceleration -- O RW -32768 to 32767
control time constant
M_SSEC_MPSV_SV057 T_SHORT SV57: High gain control constant -- O RW -32768 to 32767
M_SSEC_MPSV_SV058 T_SHORT SV58: Spindle synchronous high gain -- O RW -32768 to 32767
constant
M_SSEC_MPSV_SV059 T_SHORT SV59: Not used -- O RW -32768 to 32767
M_SSEC_MPSV_SV060 T_SHORT SV60: Not used -- O RW -32768 to 32767
M_SSEC_MPSV_SV061 T_SHORT SV61: D/A output channel 1 data No. -- O RW -32768 to 32767
M_SSEC_MPSV_SV062 T_SHORT SV62: D/A output channel 2 data No. -- O RW -32768 to 32767
M_SSEC_MPSV_SV063 T_SHORT SV63: D/A output channel 1 output -- O RW -32768 to 32767
scale
M_SSEC_MPSV_SV064 T_SHORT SV64: D/A output channel 1 output -- O RW -32768 to 32767
scale
M_SSEC_MPSV_SV065 T_SHORT SV65 -- O RW -32768 to 32767
M_SSEC_MPSV_SV073 T_SHORT SV73 -- O RW -32768 to 32767
M_SSEC_MPSV_SV074 T_SHORT SV74 -- O RW -32768 to 32767
M_SSEC_MPSV_SV075 T_SHORT SV75 -- O RW -32768 to 32767
M_SSEC_MPSV_SV076 T_SHORT SV76 -- O RW -32768 to 32767
M_SSEC_MPSV_SV081 T_SHORT SV81: Servo specification 2 -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSV_SV082 T_SHORT SV82: Special servo function selection -- O RW 0x0000 to 0xFFFF
5
M_SSEC_MPSV_SV083 T_SHORT SV83: Special servo function selection -- O RW 0x0000 to 0xFFFF
6
M_SSEC_MPSV_SV084 T_SHORT SV84: Special servo function selection -- O RW 0x0000 to 0xFFFF
7
M_SSEC_MPSV_SV085 T_SHORT SV85: Lost motion compensation 3 -- O RW 0 to 32767
Spring constant
M_SSEC_MPSV_SV086 T_SHORT SV86: Lost motion compensation 3 -- O RW 0 to 32767
Viscosity coefficient
M_SSEC_MPSV_SV087 T_SHORT SV87 -- O RW -32768 to 32767
M_SSEC_MPSV_SV088 T_SHORT SV88 -- O RW -32768 to 32767
M_SSEC_MPSV_SV089 T_SHORT SV89 -- O RW -32768 to 32767
M_SSEC_MPSV_SV090 T_SHORT SV90 -- O RW -32768 to 32767
M_SSEC_MPSV_SV091 T_SHORT SV91 -- O RW -32768 to 32767
M_SSEC_MPSV_SV092 T_SHORT SV92 -- O RW -32768 to 32767

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 135 of 206
inventcom

M_SSEC_MPSV_SV093 T_SHORT SV93 -- O RW -32768 to 32767


M_SSEC_MPSV_SV094 T_SHORT SV94 -- O RW -32768 to 32767
M_SSEC_MPSV_SV095 T_SHORT SV95 -- O RW -32768 to 32767
M_SSEC_MPSV_SV096 T_SHORT SV96 -- O RW -32768 to 32767
M_SSEC_MPSV_SV097 T_SHORT SV97 -- O RW -32768 to 32767
M_SSEC_MPSV_SV098 T_SHORT SV98 -- O RW -32768 to 32767
M_SSEC_MPSV_SV099 T_SHORT SV99 -- O RW -32768 to 32767
M_SSEC_MPSV_SV100 T_SHORT SV100 -- O RW -32768 to 32767
M_SSEC_MPSV_SV101 T_SHORT SV101 -- O RW -32768 to 32767
M_SSEC_MPSV_SV102 T_SHORT SV102 -- O RW -32768 to 32767
M_SSEC_MPSV_SV103 T_SHORT SV103 -- O RW -32768 to 32767
M_SSEC_MPSV_SV104 T_SHORT SV104 -- O RW -32768 to 32767
M_SSEC_MPSV_SV105 T_SHORT SV105 -- O RW -32768 to 32767
M_SSEC_MPSV_SV106 T_SHORT SV106 -- O RW -32768 to 32767
M_SSEC_MPSV_SV107 T_SHORT SV107 -- O RW -32768 to 32767
M_SSEC_MPSV_SV108 T_SHORT SV108 -- O RW -32768 to 32767
M_SSEC_MPSV_SV109 T_SHORT SV109 -- O RW -32768 to 32767
M_SSEC_MPSV_SV110 T_SHORT SV110 -- O RW -32768 to 32767
M_SSEC_MPSV_SV111 T_SHORT SV111 -- O RW -32768 to 32767
M_SSEC_MPSV_SV112 T_SHORT SV112 -- O RW -32768 to 32767
M_SSEC_MPSV_SV113 T_SHORT SV113 -- O RW -32768 to 32767
M_SSEC_MPSV_SV114 T_SHORT SV114 -- O RW -32768 to 32767
M_SSEC_MPSV_SV115 T_SHORT SV115 -- O RW -32768 to 32767
M_SSEC_MPSV_SV116 T_SHORT SV116 -- O RW -32768 to 32767
M_SSEC_MPSV_SV117 T_SHORT SV117 -- O RW -32768 to 32767
M_SSEC_MPSV_SV118 T_SHORT SV118 -- O RW -32768 to 32767
M_SSEC_MPSV_SV119 T_SHORT SV119 -- O RW -32768 to 32767
M_SSEC_MPSV_SV120 T_SHORT SV120 -- O RW -32768 to 32767
M_SSEC_MPSV_SV121 T_SHORT SV121 -- O RW -32768 to 32767
M_SSEC_MPSV_SV122 T_SHORT SV122 -- O RW -32768 to 32767
M_SSEC_MPSV_SV123 T_SHORT SV123 -- O RW -32768 to 32767
M_SSEC_MPSV_SV124 T_SHORT SV124 -- O RW -32768 to 32767
M_SSEC_MPSV_SV125 T_SHORT SV125 -- O RW -32768 to 32767
M_SSEC_MPSV_SV126 T_SHORT SV126 -- O RW -32768 to 32767
M_SSEC_MPSV_SV127 T_SHORT SV127 -- O RW -32768 to 32767
M_SSEC_MPSV_SV128 T_SHORT SV128 -- O RW -32768 to 32767

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 136 of 206
inventcom

M_SSEC_MPSV_SV(x) T_SHORT SV129 to SV256 (x=129 to 256) -- O RW -32768 to 32767

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 137 of 206
inventcom

Software configuration
Command Data type Description PS AX RW Range
M_SSEC_SWCFG_NC_VER T_STR NC system version -- -- R
M_SSEC_SWCFG_PLC_VER T_STR PLC version -- -- R
M_SSEC_SWCFG_PLCE_VER T_STR PLCe version (Extended external alarm -- -- R
message)
M_SSEC_SWCFG_LANG3_VER T_STR 3rd language version -- -- R
M_SSEC_SWCFG_LANG4_VER T_STR 4th language version -- -- R
M_SSEC_SWCFG_SVANP_VER T_STR Servo drive unit version -- O R
M_SSEC_SWCFG_SPAMP_VER T_STR Spindle drive unit version -- O R
M_SSEC_SWCFG_OS_VER T_STR OS version -- -- R
M_SSEC_SWCFG_APLC_VER T_STR APLC version -- -- R
M_SSEC_SWCFG_USER1_VER T_STR USER1 version -- -- R
M_SSEC_SWCFG_NC_EX_VER T_STR NC system version (4 digit display) -- -- R
M_SSEC_SWCFG_HMI_VER T_STR HMI version - - W 31 letters
M_SSEC_SWCFG_LANG_VER(x) T_STR LANGx version (x=1 to 23) - - RW 31 letters
M_SSEC_SWCFG_LADFILE_NOS T_LONG The number of registered ladder files -- -- R 0: No ladder file 1 to 32: The
number of registered ladder files -
1: Error
M_SSEC_SWCFG_LADFILE_NAME(x) T_STR Ladder file name (x=1 to 32) -- -- R 8 letters
M_SSEC_SWCFG_LADFILE_TITLE(x) T_STR Ladder file title (x=1 to 32) -- -- R 32 letters
M_SSEC_SWCFG_LADFILE_EXEC_TYPE(x) T_LONG Execution type (x=1 to 32) -- -- R 0: No registration data 1: High-
speed ladder 2: Middle-speed
ladder 3: Standby ladder 4: Low-
speed ladder 5: No execution
target -1: Error

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 138 of 206
inventcom

Speed information
Command Data type Description PS AX RW Range
M_SSEC_SPDINF_FC T_FLOATBIN FC (Combined speed) O -- R
M_SSEC_SPDINF_FA T_FLOATBIN FA: F command feedrate O -- R
M_SSEC_SPDINF_FH T_FLOATBIN FH: Head feedrate O - R
M_SSEC_SPDINF_DISP_FC T_FLOATBIN Speed display FC (Combined speed) O -- R

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 139 of 206
inventcom

Spindle analog adjustment


Command Data type Description PS AX RW Range
M_SSEC_SANA_AUTO_AJST_SET T_SHORT Automatic adjustment request -- -- W 0: Automatic adjustment cancel 1:
Automatic adjustment start
M_SSEC_SANA_AUTO_AJST_STS T_SHORT Automatic adjustment status -- -- R
M_SSEC_SANA_MANU_SELECT T_SHORT Manual adjustment data selection -- -- RW 0, 1 to 3, 11 to 13, 21 to 23, 31 to
33
M_SSEC_SANA_MANU_DATA T_SHORT Data in manual adjustment -- -- RW -999 to 999
M_SSEC_SANA_OFFSET(x) T_SHORT S analog adjustment Ch0 to 3 Offset -- -- RW -999 to 999
(x=0 to 3)
M_SSEC_SANA_PLUS_GAIN(x) T_SHORT S analog adjustment Ch0 to 3 + gain -- -- RW -999 to 999
(x=0 to 3)
M_SSEC_SANA_MINUS_GAIN(x) T_SHORT S analog adjustment Ch0 to 3 - gain -- -- RW -999 to 999
(x=0 to 3)

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 140 of 206
inventcom

Spindle information
Command Data type Description PS AX RW Range
M_SSEC_SPINF_REV_SPD T_LONG Spindle rotation speed (rev/min) -- O R 0 to 999999
M_SSEC_SPINF_LOD Spindle load value O R
M_SSEC_SPINF_OPT_SP_NO T_CHAR Spindle No. of optical spindle -- O R 1 to 4
M_SSEC_SPINF_MET_SP_NO T_CHAR Spindle No. of metal spindle -- O R 1 to 4
M_SSEC_SPINF_OPT_SP_NUM T_CHAR The total number of optical spindles -- -- R 0 to 4
M_SSEC_SPINF_MET_SP_NUM T_CHAR The total number of metal spindles -- -- R 0 to 4

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 141 of 206
inventcom

Spindle monitor
Command Data type Description PS AX RW Range
M_SSEC_MSP_WORK_TIME T_LONG Operation time -- O RW 0x00 to 0xFF
M_SSEC_MSP_ALM_HIST_TM1 T_LONG Alarm history 1 (Time) -- O RW 0x00 to 0xFF
M_SSEC_MSP_ALM_HIST_TM2 T_LONG Alarm history 2 (Time) -- O RW 0x00 to 0xFF
M_SSEC_MSP_GAIN T_LONG Gain -- O R
M_SSEC_MSP_DROOP T_LONG Droop -- O R
M_SSEC_MSP_REV_SPD T_LONG Rotation speed -- O R
M_SSEC_MSP_LOAD T_LONG Load -- O R
M_SSEC_MSP_AMP_DISP T_CHAR Drive unit display -- O R
M_SSEC_MSP_ALARM1 T_STR Alarm 1 -- O R
M_SSEC_MSP_ALARM2 T_STR Alarm 2 -- O R
M_SSEC_MSP_ALARM3 T_STR Alarm 3 -- O R
M_SSEC_MSP_ALARM4 T_STR Alarm 4 -- O R
M_SSEC_MSP_CYC_CNT T_LONG Cycle counter -- O R
M_SSEC_MSP_CMD1L T_LONG Control input 1L -- O R
M_SSEC_MSP_CMD1H T_LONG Control input 1H -- O R
M_SSEC_MSP_CMD2L T_LONG Control input 2L -- O R
M_SSEC_MSP_CMD2H T_LONG Control input 2H -- O R
M_SSEC_MSP_CMD3L T_LONG Control input 3L -- O R
M_SSEC_MSP_CMD3H T_LONG Control input 3H -- O R
M_SSEC_MSP_CMD4L T_LONG Control input 4L -- O R
M_SSEC_MSP_CMD4H T_LONG Control input 4H -- O R
M_SSEC_MSP_STS1L T_LONG Control output 1L -- O R
M_SSEC_MSP_STS1H T_LONG Control output 1H -- O R
M_SSEC_MSP_STS2L T_LONG Control output 2L -- O R
M_SSEC_MSP_STS2H T_LONG Control output 2H -- O R
M_SSEC_MSP_STS3L T_LONG Control output 3L -- O R
M_SSEC_MSP_STS3H T_LONG Control output 3H -- O R
M_SSEC_MSP_STS4L T_LONG Control output 4L -- O R
M_SSEC_MSP_STS4H T_LONG Control output 4H -- O R
M_SSEC_MSP_UNIT_TYP T_STR Drive unit type -- O R
M_SSEC_MSP_UNIT_NO T_STR Drive unit serial No. -- O R
M_SSEC_MSP_SW_VER T_STR Software version -- O R

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 142 of 206
inventcom

Spindle parameter
Command Data type Description PS AX RW Range
M_SSEC_MPSP_SP001 T_SHORT SP001: Magnetic sensor and motor -- O RW -32768 to 32767
built-in encoder orientation-mode
position loop gain
M_SSEC_MPSP_SP002 T_SHORT SP002: Encoder orientation-mode -- O RW -32768 to 32767
position loop gain
M_SSEC_MPSP_SP003 T_SHORT SP003: C-axis non-cutting position loop -- O RW -32768 to 32767
gain
M_SSEC_MPSP_SP004 T_SHORT SP004: Orientation in-position width -- O RW -32768 to 32767
M_SSEC_MPSP_SP005 T_SHORT SP005: Orientation-mode change -- O RW -32768 to 32767
speed limit value
M_SSEC_MPSP_SP006 T_SHORT SP006: Orientation-mode deceleration -- O RW -32768 to 32767
rate
M_SSEC_MPSP_SP007 T_SHORT SP007: Orientation position shift -- O RW -32768 to 32767
amount
M_SSEC_MPSP_SP008 T_SHORT SP008: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP009 T_SHORT SP009: Synchronous tapping position -- O RW -32768 to 32767
loop gain
M_SSEC_MPSP_SP010 T_SHORT SP010: Spindle synchronization position -- O RW -32768 to 32767
loop gain
M_SSEC_MPSP_SP011 T_SHORT SP011: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP012 T_SHORT SP012: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP013 T_SHORT SP013: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP014 T_SHORT SP014: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP015 T_SHORT SP015: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP016 T_SHORT SP016: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP017 T_SHORT SP017: Maximum motor speed -- O RW -32768 to 32767
M_SSEC_MPSP_SP018 T_SHORT SP018: Motor zero speed -- O RW -32768 to 32767
M_SSEC_MPSP_SP019 T_SHORT SP019: Speed command -- O RW -32768 to 32767
acceleration/deceleration time constant
M_SSEC_MPSP_SP020 T_SHORT SP020: Speed detection set value -- O RW -32768 to 32767
M_SSEC_MPSP_SP021 T_SHORT SP021: Torque limit 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP022 T_SHORT SP022: Speed loop gain proportional -- O RW -32768 to 32767
term under speed control

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 143 of 206
inventcom

M_SSEC_MPSP_SP023 T_SHORT SP023: Speed loop gain integral term -- O RW -32768 to 32767
under speed control
M_SSEC_MPSP_SP024 T_SHORT SP024: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP025 T_SHORT SP025: Spindle gear teeth count 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP026 T_SHORT SP026: Spindle gear teeth count 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP027 T_SHORT SP027: Spindle gear teeth count 3 -- O RW -32768 to 32767
M_SSEC_MPSP_SP028 T_SHORT SP028: Spindle gear teeth count 4 -- O RW -32768 to 32767
M_SSEC_MPSP_SP029 T_SHORT SP029: Motor shaft gear teeth count 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP030 T_SHORT SP030: Motor shaft gear teeth count 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP031 T_SHORT SP031: Motor shaft gear teeth count 3 -- O RW -32768 to 32767
M_SSEC_MPSP_SP032 T_SHORT SP032: Motor shaft gear teeth count 4 -- O RW -32768 to 32767
M_SSEC_MPSP_SP033 T_SHORT SP033: Spindle function 1 -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP034 T_SHORT SP034: Spindle function 2 -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP035 T_SHORT SP035: Spindle function 3 -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP036 T_SHORT SP036: Spindle function 4 -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP037 T_SHORT SP037: Spindle function 5 -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP038 T_SHORT SP038: Spindle function 6 -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP039 T_SHORT SP039: Drive unit type -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP040 T_SHORT SP040: Motor type -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP041 T_SHORT SP041: Regenerative resistor type -- O RW 0x0000 to 0xFFFF
(SPJ)/Power supply type (SP)
M_SSEC_MPSP_SP042 T_SHORT SP042: Detector range for C axis -- O RW -32768 to 32767
M_SSEC_MPSP_SP043 T_SHORT SP043: Detector range for synchronous -- O RW -32768 to 32767
tapping, spindle synchronization
M_SSEC_MPSP_SP044 T_SHORT SP044: NC communication frequency -- O RW -32768 to 32767
M_SSEC_MPSP_SP045 T_SHORT SP045: Not used -- O RW -32768 to 32767

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 144 of 206
inventcom

Spindle specification parameter


Command Data type Description PS AX RW Range
M_SSEC_MPSSPC_SALIM1 T_LONG The number of limit rotation gears 00 -- O RW 0 to 99999
M_SSEC_MPSSPC_SALIM2 T_LONG The number of limit rotation gears 01 -- O RW 0 to 99999
M_SSEC_MPSSPC_SALIM3 T_LONG The number of limit rotation gears 10 -- O RW 0 to 99999
M_SSEC_MPSSPC_SALIM4 T_LONG The number of limit rotation gears 11 -- O RW 0 to 99999
M_SSEC_MPSSPC_SAMAX1 T_LONG The number of maximum rotation gears -- O RW 0 to 99999
00
M_SSEC_MPSSPC_SAMAX2 T_LONG The number of maximum rotation gears -- O RW 0 to 99999
01
M_SSEC_MPSSPC_SAMAX3 T_LONG The number of maximum rotation gears -- O RW 0 to 99999
10
M_SSEC_MPSSPC_SAMAX4 T_LONG The number of maximum rotation gears -- O RW 0 to 99999
11
M_SSEC_MPSSPC_SASIFT1 T_SHORT The number of shift rotation gears 00 -- O RW 0 to 32767
M_SSEC_MPSSPC_SASIFT2 T_SHORT The number of shift rotation gears 01 -- O RW 0 to 32767
M_SSEC_MPSSPC_SASIFT3 T_SHORT The number of shift rotation gears 10 -- O RW 0 to 32767
M_SSEC_MPSSPC_SASIFT4 T_SHORT The number of shift rotation gears 11 -- O RW 0 to 32767
M_SSEC_MPSSPC_SATAP1 T_LONG The number of tapping rotation gears -- O RW 0 to 99999
00
M_SSEC_MPSSPC_SATAP2 T_LONG The number of tapping rotation gears -- O RW 0 to 99999
01
M_SSEC_MPSSPC_SATAP3 T_LONG The number of tapping rotation gears -- O RW 0 to 99999
10
M_SSEC_MPSSPC_SATAP4 T_LONG The number of tapping rotation gears -- O RW 0 to 99999
11
M_SSEC_MPSSPC_SATPST1 T_SHORT Tapping time constant gear 00 -- O RW 1 to 5000
M_SSEC_MPSSPC_SATPST2 T_SHORT Tapping time constant gear 01 -- O RW 1 to 5000
M_SSEC_MPSSPC_SATPST3 T_SHORT Tapping time constant gear 10 -- O RW 1 to 5000
M_SSEC_MPSSPC_SATPST4 T_SHORT Tapping time constant gear 11 -- O RW 1 to 5000
M_SSEC_MPSSPC_SAORI T_SHORT The number of orientation rotation -- O RW 0 to 32767
M_SSEC_MPSSPC_ENCRATE T_CHAR Encoder gear ratio -- O RW 0 to 3
M_SSEC_MPSSPC_SMIN T_SHORT Smin (Minimum rotation speed -- O RW 0 to 32767
possible to set)

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 145 of 206
inventcom

M_SSEC_MPSSPC_SLIMIT Slimit (Maximum rotation speed


possible to set)
M_SSEC_MPSSPC_SDAOUT T_CHAR Spindle connection -- O RW 0 to 5
M_SSEC_MPSSPC_ENCON T_CHAR Spindle encoder -- O RW 0 to 2
M_SSEC_MPSSPC_CSORI T_CHAR Coil selection specification in -- O RW 0,1
orientation
M_SSEC_MPSSPC_CSSYN T_CHAR Coil selection specification in spindle -- O RW 0,1
synchronization (polygon)
M_SSEC_MPSSPC_SPRCMM T_LONG Spindle forward/reverse rotation M -- O RW 0 to 999999
command
M_SSEC_MPSSPC_TAPSEL T_CHAR Asynchronous tapping gear selection -- O RW 0,1
M_SSEC_MPSSPC_SMCP_NO T_SHORT Drive unit interface channel No. -- O RW 0x0, 0x101 to 0x107, 0x201 to
0x207
M_SSEC_MPSSPC_OUTUNIT T_STR Output unit (Spindle) -- O RW A,B,C,D,E
M_SSEC_MPSSPC_TAPERR T_SHORT Synchronous tapping allowable error -- O RW 0 to 1000
M_SSEC_MPSSPC_SATAP2_1 T_LONG Synchronous tapping switch spindle -- O RW 0 to 99999
rotation speed 2 Gear 00
M_SSEC_MPSSPC_SATAP2_2 T_LONG Synchronous tapping switch spindle -- O RW 0 to 99999
rotation speed 2 Gear 01
M_SSEC_MPSSPC_SATAP2_3 T_LONG Synchronous tapping switch spindle -- O RW 0 to 99999
rotation speed 2 Gear 10
M_SSEC_MPSSPC_SATAP2_4 T_LONG Synchronous tapping switch spindle -- O RW 0 to 99999
rotation speed 2 Gear 11
M_SSEC_MPSSPC_SATPST2_1 T_SHORT Synchronous tapping switch time -- O RW 1 to 5000
constant 2 gear 00
M_SSEC_MPSSPC_SATPST2_2 T_SHORT Synchronous tapping switch time -- O RW 1 to 5000
constant 2 gear 01
M_SSEC_MPSSPC_SATPST2_3 T_SHORT Synchronous tapping switch time -- O RW 1 to 5000
constant 2 gear 10
M_SSEC_MPSSPC_SATPST2_4 T_SHORT Synchronous tapping switch time -- O RW 1 to 5000
constant 2 gear 11
M_SSEC_MPSSPC_SATPST3_1 T_SHORT Synchronous tapping switch time -- O RW 1 to 5000
constant 3 gear 00
M_SSEC_MPSSPC_SATPST3_2 T_SHORT Synchronous tapping switch time -- O RW 1 to 5000
constant 3 gear 01
M_SSEC_MPSSPC_SATPST3_3 T_SHORT Synchronous tapping switch time -- O RW 1 to 5000
constant 3 gear 10

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 146 of 206
inventcom

M_SSEC_MPSSPC_SATPST3_4 T_SHORT Synchronous tapping switch time -- O RW 1 to 5000


constant 3 gear 11
M_SSEC_MPSSPC_SPT T_SHORT Spindle synchronous -- O RW 0 to 9999
acceleration/deceleration time constant
M_SSEC_MPSSPC_DPRLV T_SHORT Spindle synchronous rotation speed -- O RW 0 to 4095
reach level
M_SSEC_MPSSPC_SPPLV T_SHORT Spindle synchronous phase reach level -- O RW 0 to 4095
M_SSEC_MPSSPC_SPPLR T_CHAR Spindle control flag 1 BIT0: spindle -- O RW 0,1
motor / spindle, relative polarity
M_SSEC_MPSSPC_SPPST T_LONG Spindle synchronous phase shift -- O RW 0 to 359999
M_SSEC_MPSSPC_SPTC1 T_LONG Spindle Synchronous multi-step -- O RW 0 to 99999
acceleration/deceleration time constant
switch speed1
M_SSEC_MPSSPC_SPTC2 T_LONG Spindle Synchronous multi-step -- O RW 0 to 99999
acceleration/deceleration time constant
switch speed2
M_SSEC_MPSSPC_SPTC3 T_LONG Spindle Synchronous multi-step -- O RW 0 to 99999
acceleration/deceleration time constant
switch speed3
M_SSEC_MPSSPC_SPTC4 T_LONG Spindle Synchronous multi-step -- O RW 0 to 99999
acceleration/deceleration time constant
switch speed4
M_SSEC_MPSSPC_SPTC5 T_LONG Spindle Synchronous multi-step -- O RW 0 to 99999
acceleration/deceleration time constant
switch speed5
M_SSEC_MPSSPC_SPTC6 T_LONG Spindle Synchronous multi-step -- O RW 0 to 99999
acceleration/deceleration time constant
switch speed6
M_SSEC_MPSSPC_SPTC7 T_LONG Spindle Synchronous multi-step -- O RW 0 to 99999
acceleration/deceleration time constant
switch speed7
M_SSEC_MPSSPC_SPDIV1 T_CHAR Scale at time constant switch speed 1 -- O RW 0 to 127
(1/n)
M_SSEC_MPSSPC_SPDIV2 T_CHAR Scale at time constant switch speed 2 -- O RW 0 to 127
(1/n)
M_SSEC_MPSSPC_SPDIV3 T_CHAR Scale at time constant switch speed 3 -- O RW 0 to 127
(1/n)

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 147 of 206
inventcom

M_SSEC_MPSSPC_SPDIV4 T_CHAR Scale at time constant switch speed 4 -- O RW 0 to 127


(1/n)
M_SSEC_MPSSPC_SPDIV5 T_CHAR Scale at time constant switch speed 5 -- O RW 0 to 127
(1/n)
M_SSEC_MPSSPC_SPDIV6 T_CHAR Scale at time constant switch speed 6 -- O RW 0 to 127
(1/n)
M_SSEC_MPSSPC_SPDIV7 T_CHAR Scale at time constant switch speed 7 -- O RW 0 to 127
(1/n)
M_SSEC_MPSSPC_SYMTM1 T_SHORT Spindle synchronization stationary time -- O RW 0 to 9999
1 before phase alignment
M_SSEC_MPSSPC_SYMTM2 T_SHORT Spindle synchronization stationary time -- O RW 0 to 9999
2 after phase alignment
M_SSEC_MPSSPC_SYPRT T_CHAR Spindle synchronization phase -- O RW 0 to 100
alignment deceleration rate
M_SSEC_MPSSPC_SSCDRSELSP T_SHORT Speed monitor Door selection - O RW 0000 to 0003
M_SSEC_MPSSPC_SSCSVOFFLTRSP T_SHORT Speed monitor Error detection time - O RW 0 to 9999
during servo OFF
M_SSEC_MPSSPC_SPTS1 T_SHORT Time constant for spindle rotation with -- O RW 1 to 5000
S command (Gear: 00)
M_SSEC_MPSSPC_SPTS2 T_SHORT Time constant for spindle rotation with -- O RW 1 to 5000
S command (Gear: 01)
M_SSEC_MPSSPC_SPTS3 T_SHORT Time constant for spindle rotation with -- O RW 1 to 5000
S command (Gear: 10)
M_SSEC_MPSSPC_SPTS4 T_SHORT Time constant for spindle rotation with -- O RW 1 to 5000
S command (Gear: 11)
M_SSEC_MPSSPC_SUT T_CHAR Speed reach range -- O RW 0 to 100
M_SSEC_MPSSPC_ORITYP T_SHORT Orientation specification -- O RW 0x0000 to 0xffff
M_SSEC_MPSSPC_ORISPD T_LONG Orientation speed -- O RW 1 to 99999
M_SSEC_MPSSPC_ORISFT T_LONG Orientation in-position shift amount -- O RW -35999 to 35999
M_SSEC_MPSSPC_ZDETSPD T_LONG Initial Z phase detection speed -- O RW 1 to 99999
M_SSEC_MPSSPC_TAPSPD T_LONG Synchronous tapping reference position -- O RW 1 to 99999
return speed
M_SSEC_MPSSPC_TAPSFT T_USHORT Synchronous tapping reference position -- O RW 0 to 35999
return shift amount
M_SSEC_MPSSPC_CAXSPD T_LONG ï¼£ axis reference position return -- O RW 1 to 99999
speed

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 148 of 206
inventcom

M_SSEC_MPSSPC_CAXSFT T_LONG C axis reference position return shift -- O RW 0 to 359999


amount
M_SSEC_MPSSPC_CAXPARACHG T_UCHAR Spindle/C axis parameter switch -- O RW 0 to 1
M_SSEC_MPSSPC_SP2TS1 T_USHORT Time constant in orientation/position -- O RW 1 to 20000
loop reference position return (Gear:
00)
M_SSEC_MPSSPC_SP2TS2 T_USHORT Time constant in orientation/position -- O RW 1 to 20000
loop reference position return (Gear:
01)
M_SSEC_MPSSPC_SP2TS3 T_USHORT Time constant in orientation/position -- O RW 1 to 20000
loop reference position return (Gear:
10)
M_SSEC_MPSSPC_SP2TS4 T_USHORT Time constant in orientation/position -- O RW 1 to 20000
loop reference position return (Gear:
11)
M_SSEC_MPSSPC_STAPTR T_USHORT Time constant reduction rate in high- - O RW 0 to 100
speed synchronous tapping
M_SSEC_MPSSPC_TRET T_UCHAR Turret indexing - O RW 0 to 1
M_SSEC_MPSSPC_GRC T_USHORT Turret side gear ratio - O RW 0 to 32767
M_SSEC_MPSSPC_TRET_SPD T_USHORT Turret indexing speed - O RW 0 to 32767
M_SSEC_MPSSPC_TRET_T T_USHORT Turret indexing time constant - O RW 0 to 30000
M_SSEC_MPSSPC_TRET_INPOS T_USHORT Turret indexing in-position width - O RW 0 to 32767
M_SSEC_MPSSPC_TRET_FIN_OFF T_USHORT Index positioning complete signal OFF - O RW 0 to 10000
timer
M_SSEC_MPSSPC_SPEC_SP T_SHORT Spindle specification - O RW 0 to FFFF
M_SSEC_MPSSPC_ORI_SPEC T_SHORT Orientation specification - O RW 0 to FFFF
M_SSEC_MPSSPC_CAX_SPEC T_SHORT Spindle/C axis specification - O RW 0 to FFFF
M_SSEC_MPSSPC_SYN_SPEC T_SHORT Spindle synchronization specification - O RW 0 to FFFF
M_SSEC_MPSSPC_TAP_SPEC T_SHORT Synchronous tapping specification - O RW 0 to FFFF
M_SSEC_MPSSPC_ORI_INP2 T_USHORT 2nd in-position width for orientation - O RW 0 to 32767
M_SSEC_MPSSPC_HOBERRPHS T_USHORT Hobbing axis delay (advance) allowable - O RW 0 to 32767
angle
M_SSEC_MPSSPC_HOBCMPT T_USHORT Primary delay time constant for - O RW 0 to 32767
hobbing axis automatic compensation
M_SSEC_MPSSPC_HOBFFG T_USHORT Feed forward gain for hobbing axis - O RW 0 to 200
M_SSEC_MPSSPC_STAP_AX_OFF T_USHORT High-speed synchronous tapping -- O RW 0x0000 to 0xFFFF
disabled axis

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 149 of 206
inventcom

Spindle/Standby
Command Data type Description PS AX RW Range
M_SSEC_SPWAIT_TOOL_NO(x) T_LONG Spindle stand by (Tool No.) (x=0 to 4) O -- RW (To designate part system,
designate magazine)
M_SSEC_SPWAIT_D_NO(x) T_SHORT Spindle stand by (Auxiliary: D) (x=0 to O -- RW (To designate part system,
4) designate magazine)
M_SSEC_SPWAIT_DISP_NOS T_LONG The number of spindles stand by to -- -- R
display
M_SSEC_SPWAIT_SPINDL_TLIFE T_STR Spindle tool's life management data O -- R (To designate part system,
designate magazine)
M_SSEC_SPWAIT_WAIT_TLIFE T_STR Stand by tool's life management data O -- R (To designate part system,
designate magazine)

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 150 of 206
inventcom

Symbol (Sub-section)
Command Data type Description PS AX RW Range
M_SSEC_PLCINDXPRM_PSW13DOG2 T_FLOATBIN PSW13 Area setting 2 - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_PSW14DOG1 T_FLOATBIN PSW14 Area setting 1 - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_PSW14DOG2 T_FLOATBIN PSW14 Area setting 2 - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_PSW15DOG1 T_FLOATBIN PSW15 Area setting 1 - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_PSW15DOG2 T_FLOATBIN PSW15 Area setting 2 - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_PUSHT T_FLOATBIN Stopper amount - O RW 0 to 359.999
M_SSEC_PLCINDXPRM_PUSHT1 T_SHORT Stopper standby time - O RW 0 to 9999
M_SSEC_PLCINDXPRM_PUSHT2 T_SHORT Stopper torque release time - O RW 0 to 9999
M_SSEC_PLCINDXPRM_PUSHT3 T_SHORT Set position signal output delay time - O RW 0 to 9999
M_SSEC_TOFS2S_WEAR_L(x) T_FLOATBIN/T_LONG Wear in length (x=1 to 999) O -- RW ±99999.999
M_SSEC_TOFS2S_WEAR_R(x) T_FLOATBIN/T_LONG Wear in diameter (x=1 to 999) O -- RW ±999.999
M_SSEC_PLCINDXPRM_TL2 T_SHORT Operation parameter group 2 Torque - O RW 0 to 500
limit value
M_SSEC_PLCINDXPRM_OD2 T_SHORT Operation parameter group 2 Excessive - O RW 0 to 32767
error detection width
M_SSEC_PLCINDXPRM_JUST2 T_FLOATBIN Operation parameter group 2 Set - O RW 0 to 99999.999
position output width
M_SSEC_PLCINDXPRM_NEAR2 T_FLOATBIN Operation parameter group 2 Near set - O RW 0 to 99999.999
position output width
M_SSEC_PLCINDXPRM_SMGST2 T_SHORT Operation parameter group 2 - O RW 0x01,0x0F
Acceleration/deceleration type
M_SSEC_PLCINDXPRM_ASPEED3 T_LONG Operation parameter group 3 - O RW 1 to 100000
Automatic operation speed
M_SSEC_PLCINDXPRM_MSPEED3 T_LONG Operation parameter group 3 Manual - O RW 1 to 100000
operation speed
M_SSEC_PLCINDXPRM_TIMEL3_1 T_SHORT Operation parameter group 3 - O RW 1 to 9999
Acceleration/deceleration time constant
1
M_SSEC_PLCINDXPRM_TIMEL3_2 T_SHORT Operation parameter group 3 - O RW 1 to 999
Acceleration/deceleration time constant
2
M_SSEC_PLCINDXPRM_TL3 T_SHORT Operation parameter group 3 Torque - O RW 0 to 500
limit value

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 151 of 206
inventcom

M_SSEC_PLCINDXPRM_OD3 T_SHORT Operation parameter group 3 Excessive - O RW 0 to 32767


error detection width
M_SSEC_PLCINDXPRM_JUST3 T_FLOATBIN Operation parameter group 3 Set - O RW 0 to 99999.999
position output width
M_SSEC_PLCINDXPRM_NEAR3 T_FLOATBIN Operation parameter group 3 Near set - O RW 0 to 99999.999
position output width
M_SSEC_PLCINDXPRM_SMGST3 T_SHORT Operation parameter group 3 - O RW 0x01,0x0F
Acceleration/deceleration type
M_SSEC_PLCINDXPRM_ASPEED4 T_LONG Operation parameter group 4 - O RW 1 to 100000
Automatic operation speed
M_SSEC_PLCINDXPRM_MSPEED4 T_LONG Operation parameter group 4 Manual - O RW 1 to 100000
operation speed
M_SSEC_PLCINDXPRM_TIMEL4_1 T_SHORT Operation parameter group 4 - O RW 1 to 9999
Acceleration/deceleration time constant
1
M_SSEC_PLCINDXPRM_TIMEL4_2 T_SHORT Operation parameter group 4 - O RW 1 to 999
Acceleration/deceleration time constant
2
M_SSEC_PLCINDXPRM_TL4 T_SHORT Operation parameter group 4 Torque - O RW 0 to 500
limit value
M_SSEC_PLCINDXPRM_OD4 T_SHORT Operation parameter group 4 Excessive - O RW 0 to 32767
error detection width
M_SSEC_PLCINDXPRM_JUST4 T_FLOATBIN Operation parameter group 4 Set - O RW 0 to 99999.999
position output width
M_SSEC_PLCINDXPRM_NEAR4 T_FLOATBIN Operation parameter group 4 Near set - O RW 0 to 99999.999
position output width
M_SSEC_PLCINDXPRM_SMGST4 T_SHORT Operation parameter group 4 - O RW 0x01,0x0F
Acceleration/deceleration type
M_SSEC_PLCINDXPRM_STPOS2 T_FLOATBIN Station 2 coordinate value - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_STPOS3 T_FLOATBIN Station 3 coordinate value - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_STPOS4 T_FLOATBIN Station 4 coordinate value - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_STPOS5 T_FLOATBIN Station 5 coordinate value - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_STPOS6 T_FLOATBIN Station 6 coordinate value - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_STPOS7 T_FLOATBIN Station 7 coordinate value - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_STPOS8 T_FLOATBIN Station 8 coordinate value - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_STPOS9 T_FLOATBIN Station 9 coordinate value - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_STPOS10 T_FLOATBIN Station 10 coordinate value - O RW -99999.999 to 99999.999

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 152 of 206
inventcom

M_SSEC_PLCINDXPRM_STPOS11 T_FLOATBIN Station 11 coordinate value - O RW -99999.999 to 99999.999


M_SSEC_PLCINDXPRM_STPOS12 T_FLOATBIN Station 12 coordinate value - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_STPOS13 T_FLOATBIN Station 13 coordinate value - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_STPOS14 T_FLOATBIN Station 14 coordinate value - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_STPOS15 T_FLOATBIN Station 15 coordinate value - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_STPOS16 T_FLOATBIN Station 16 coordinate value - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_STPOS17 T_FLOATBIN Station 17 coordinate value - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_STPOS18 T_FLOATBIN Station 18 coordinate value - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_STPOS19 T_FLOATBIN Station 19 coordinate value - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_STPOS20 T_FLOATBIN Station 20 coordinate value - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_PSWCHECK T_CHAR PSW detection method - O RW 0 to 0xFF
M_SSEC_PLCINDXPRM_PSW1DOG1 T_FLOATBIN PSW1 Area setting 1 - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_PSW1DOG2 T_FLOATBIN PSW1 Area setting 2 - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_PSW2DOG1 T_FLOATBIN PSW2 Area setting 1 - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_PSW2DOG2 T_FLOATBIN PSW2 Area setting 2 - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_PSW3DOG1 T_FLOATBIN PSW3 Area setting 1 - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_PSW3DOG2 T_FLOATBIN PSW3 Area setting 2 - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_PSW4DOG1 T_FLOATBIN PSW4 Area setting 1 - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_PSW4DOG2 T_FLOATBIN PSW4 Area setting 2 - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_PSW5DOG1 T_FLOATBIN PSW5 Area setting 1 - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_PSW5DOG2 T_FLOATBIN PSW5 Area setting 2 - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_PSW6DOG1 T_FLOATBIN PSW6 Area setting 1 - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_PSW6DOG2 T_FLOATBIN PSW6 Area setting 2 - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_PSW7DOG1 T_FLOATBIN PSW7 Area setting 1 - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_PSW7DOG2 T_FLOATBIN PSW7 Area setting 2 - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_PSW8DOG1 T_FLOATBIN PSW8 Area setting 1 - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_PSW8DOG2 T_FLOATBIN PSW8 Area setting 2 - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_PSW9DOG1 T_FLOATBIN PSW9 Area setting 1 - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_PSW9DOG2 T_FLOATBIN PSW9 Area setting 2 - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_PSW10DOG1 T_FLOATBIN PSW10 Area setting 1 - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_PSW10DOG2 T_FLOATBIN PSW10 Area setting 2 - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_PSW11DOG1 T_FLOATBIN PSW11 Area setting 1 - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_PSW11DOG2 T_FLOATBIN PSW11 Area setting 2 - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_PSW12DOG1 T_FLOATBIN PSW12 Area setting 1 - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_PSW12DOG2 T_FLOATBIN PSW12 Area setting 2 - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_PSW13DOG1 T_FLOATBIN PSW13 Area setting 1 - O RW -99999.999 to 99999.999

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 153 of 206
inventcom

M_SSEC_MPSP_SP225 T_SHORT SP225: Spindle gear teeth count 5 -- O RW -32768 to 32767


M_SSEC_MPSP_SP226 T_SHORT SP226: Spindle gear teeth count 6 -- O RW -32768 to 32767
M_SSEC_MPSP_SP227 T_SHORT SP227: Spindle gear teeth count 7 -- O RW -32768 to 32767
M_SSEC_MPSP_SP228 T_SHORT SP228: Spindle gear teeth count 8 -- O RW -32768 to 32767
M_SSEC_MPSP_SP229 T_SHORT SP229: Motor shaft gear teeth count 5 -- O RW -32768 to 32767
M_SSEC_MPSP_SP230 T_SHORT SP230: Motor shaft gear teeth count 6 -- O RW -32768 to 32767
M_SSEC_MPSP_SP231 T_SHORT SP231: Motor shaft gear teeth count 7 -- O RW -32768 to 32767
M_SSEC_MPSP_SP232 T_SHORT SP232: Motor shaft gear teeth count 8 -- O RW -32768 to 32767
M_SSEC_MPSP_SP233 T_SHORT SP233: Disturbance observer general -- O RW -32768 to 32767
inertia scale
M_SSEC_MPSP_SP234 T_SHORT SP234: Disturbance observer low path -- O RW -32768 to 32767
filter frequency
M_SSEC_MPSP_SP235 T_SHORT SP235: Disturbance observer gain -- O RW -32768 to 32767
M_SSEC_MPSP_SP236 T_SHORT SP236: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP237 T_SHORT SP237: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP238 T_SHORT SP238: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP239 T_SHORT SP239: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP240 T_SHORT SP240: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP241 T_SHORT SP241: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP242 T_SHORT SP242: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP243 T_SHORT SP243: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP244 T_SHORT SP244: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP245 T_SHORT SP245: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP246 T_SHORT SP246: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP247 T_SHORT SP247: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP248 T_SHORT SP248: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP249 T_SHORT SP249: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP250 T_SHORT SP250: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP251 T_SHORT SP251: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP252 T_SHORT SP252: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP253 T_SHORT SP253: D/A output channel 1 data -- O RW -32768 to 32767
number
M_SSEC_MPSP_SP254 T_SHORT SP254: D/A output channel 2 data -- O RW -32768 to 32767
number
M_SSEC_MPSP_SP255 T_SHORT SP255: D/A output channel 3 data -- O RW -32768 to 32767
number

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 154 of 206
inventcom

M_SSEC_MPSP_SP256 T_SHORT SP256: D/A output channel 4 data -- O RW -32768 to 32767


number
M_SSEC_MPSP_SP257 T_SHORT SP257: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP258 T_SHORT SP258: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP259 T_SHORT SP259: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP260 T_SHORT SP260: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP261 T_SHORT SP261: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP262 T_SHORT SP262: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP263 T_SHORT SP263: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP264 T_SHORT SP264: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP265 T_SHORT SP265: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP266 T_SHORT SP266: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP267 T_SHORT SP267: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP268 T_SHORT SP268: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP269 T_SHORT SP269: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP270 T_SHORT SP270: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP271 T_SHORT SP271: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP272 T_SHORT SP272: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP273 T_SHORT SP273: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP274 T_SHORT SP274: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP275 T_SHORT SP275: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP276 T_SHORT SP276: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP277 T_SHORT SP277: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP278 T_SHORT SP278: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP279 T_SHORT SP279: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP280 T_SHORT SP280: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP281 T_SHORT SP281: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP282 T_SHORT SP282: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP283 T_SHORT SP283: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP284 T_SHORT SP284: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP285 T_SHORT SP285: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP286 T_SHORT SP286: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP287 T_SHORT SP287: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP288 T_SHORT SP288: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP289 T_SHORT SP289: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP290 T_SHORT SP290: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 155 of 206
inventcom

M_SSEC_MPSP_SP291 T_SHORT SP291: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF


M_SSEC_MPSP_SP292 T_SHORT SP292: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP293 T_SHORT SP293: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP294 T_SHORT SP294: Disturbance observer torque -- O RW 0x0000 to 0xFFFF
constant
M_SSEC_MPSP_SP295 T_SHORT SP295: Disturbance observer motor -- O RW 0x0000 to 0xFFFF
inertia
M_SSEC_MPSP_SP296 T_SHORT SP296: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP297 T_SHORT SP297: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP298 T_SHORT SP298: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP299 T_SHORT SP299: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP300 T_SHORT SP300: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP301 T_SHORT SP301: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP302 T_SHORT SP302: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP303 T_SHORT SP303: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP304 T_SHORT SP304: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP305 T_SHORT SP305: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP306 T_SHORT SP306: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP307 T_SHORT SP307: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP308 T_SHORT SP308: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP309 T_SHORT SP309: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP310 T_SHORT SP310: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP311 T_SHORT SP311: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP312 T_SHORT SP312: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP313 T_SHORT SP313: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP314 T_SHORT SP314: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP315 T_SHORT SP315: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP316 T_SHORT SP316: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP317 T_SHORT SP317: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP318 T_SHORT SP318: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP319 T_SHORT SP319: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP320 T_SHORT SP320: Motor constant (H coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP321 T_SHORT SP321: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP322 T_SHORT SP322: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP323 T_SHORT SP323: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP324 T_SHORT SP324: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 156 of 206
inventcom

M_SSEC_MPSP_SP325 T_SHORT SP325: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF


M_SSEC_MPSP_SP326 T_SHORT SP326: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP327 T_SHORT SP327: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP328 T_SHORT SP328: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP329 T_SHORT SP329: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP330 T_SHORT SP330: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP331 T_SHORT SP331: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP332 T_SHORT SP332: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP333 T_SHORT SP333: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP334 T_SHORT SP334: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP335 T_SHORT SP335: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP336 T_SHORT SP336: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP337 T_SHORT SP337: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP338 T_SHORT SP338: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP339 T_SHORT SP339: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP340 T_SHORT SP340: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP341 T_SHORT SP341: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP342 T_SHORT SP342: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP343 T_SHORT SP343: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP344 T_SHORT SP344: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP345 T_SHORT SP345: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP346 T_SHORT SP346: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP347 T_SHORT SP347: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP348 T_SHORT SP348: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP349 T_SHORT SP349: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP350 T_SHORT SP350: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP351 T_SHORT SP351: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP352 T_SHORT SP352: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP353 T_SHORT SP353: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP354 T_SHORT SP354: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP355 T_SHORT SP355: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP356 T_SHORT SP356: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP357 T_SHORT SP357: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP358 T_SHORT SP358: Disturbance observer torque -- O RW 0x0000 to 0xFFFF
constant 2

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 157 of 206
inventcom

M_SSEC_MPSP_SP359 T_SHORT SP359: Disturbance observer motor -- O RW 0x0000 to 0xFFFF


inertia 2
M_SSEC_MPSP_SP360 T_SHORT SP360: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP361 T_SHORT SP361: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP362 T_SHORT SP362: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP363 T_SHORT SP363: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP364 T_SHORT SP364: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP365 T_SHORT SP365: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP366 T_SHORT SP366: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP367 T_SHORT SP367: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP368 T_SHORT SP368: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP369 T_SHORT SP369: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP370 T_SHORT SP370: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP371 T_SHORT SP371: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP372 T_SHORT SP372: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP373 T_SHORT SP373: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP374 T_SHORT SP374: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP375 T_SHORT SP375: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP376 T_SHORT SP376: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP377 T_SHORT SP377: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP378 T_SHORT SP378: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP379 T_SHORT SP379: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP380 T_SHORT SP380: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP381 T_SHORT SP381: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP382 T_SHORT SP382: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP383 T_SHORT SP383: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP384 T_SHORT SP384: Motor constant (L coil) -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP1001 T_SHORT SP1001: Position gain normal -- O RW -32768 to 32767
M_SSEC_MPSP_SP1002 T_SHORT SP1002: Position gain in spindle -- O RW -32768 to 32767
synchronization
M_SSEC_MPSP_SP1003 T_SHORT SP1003: Position gain in C axis -- O RW -32768 to 32767
M_SSEC_MPSP_SP1004 T_SHORT SP1004: Position gain in in -- O RW -32768 to 32767
synchronous tapping
M_SSEC_MPSP_SP1005 T_SHORT SP1005: Speed gain 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1006 T_SHORT SP1006: Speed lead compensation 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1007 T_SHORT SP1007: Speed delay compensation 1 -- O RW -32768 to 32767

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 158 of 206
inventcom

M_SSEC_MPSP_SP1008 T_SHORT SP1008: Speed gain 2 -- O RW -32768 to 32767


M_SSEC_MPSP_SP1009 T_SHORT SP1009: Speed lead compensation 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1010 T_SHORT SP1010: Speed delay compensation 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1011 T_SHORT SP1011: Variable current gain starting -- O RW -32768 to 32767
speed
M_SSEC_MPSP_SP1012 T_SHORT SP1012: Variable current gain finishing -- O RW -32768 to 32767
speed
M_SSEC_MPSP_SP1013 T_SHORT SP1013: Variable current gain scale -- O RW -32768 to 32767
M_SSEC_MPSP_SP1014 T_SHORT SP1014: Minimum excitation rate 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1015 T_SHORT SP1015: Minimum excitation rate 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1016 T_SHORT SP1016: Phase compensation time -- O RW -32768 to 32767
constant
M_SSEC_MPSP_SP1017 T_SHORT SP1017: Spindle specification 1 -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP1018 T_SHORT SP1018: Spindle specification 2 -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP1019 T_SHORT SP1019: Position encoder resolution -- O RW -32768 to 32767
(Spindle end)
M_SSEC_MPSP_SP1020 T_SHORT SP1020: Speed encoder resolution -- O RW -32768 to 32767
(Motor end)
M_SSEC_MPSP_SP1021 T_SHORT SP1021: Overload alarm detection time -- O RW -32768 to 32767
M_SSEC_MPSP_SP1022 T_SHORT SP1022: Overload alarm detection level -- O RW -32768 to 32767
M_SSEC_MPSP_SP1023 T_SHORT SP1023: Excessive error detection -- O RW -32768 to 32767
width (Position mode)
M_SSEC_MPSP_SP1024 T_SHORT SP1024: In-position width -- O RW -32768 to 32767
M_SSEC_MPSP_SP1025 T_SHORT SP1025: 2nd in-position width -- O RW -32768 to 32767
M_SSEC_MPSP_SP1026 T_SHORT SP1026: Motor maximum speed -- O RW -32768 to 32767
M_SSEC_MPSP_SP1027 T_SHORT SP1027: Motor zero speed -- O RW -32768 to 32767
M_SSEC_MPSP_SP1028 T_SHORT SP1028: Speed detection setting value -- O RW -32768 to 32767
M_SSEC_MPSP_SP1029 T_SHORT SP1029: Speed detection reset width -- O RW -32768 to 32767
M_SSEC_MPSP_SP1030 T_SHORT SP1030: 2nd speed detection setting -- O RW -32768 to 32767
value
M_SSEC_MPSP_SP1031 T_SHORT SP1031: Motor type -- O RW -32768 to 32767
M_SSEC_MPSP_SP1032 T_SHORT SP1032: Power supply type -- O RW -32768 to 32767
M_SSEC_MPSP_SP1033 T_SHORT SP1033: Spindle function 1 -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP1034 T_SHORT SP1034: Spindle function 2 -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP1035 T_SHORT SP1035: Spindle function 3 -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP1036 T_SHORT SP1036: Spindle function 4 -- O RW 0x0000 to 0xFFFF

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 159 of 206
inventcom

M_SSEC_MPSP_SP1037 T_SHORT SP1037: Load inertia scale -- O RW -32768 to 32767


M_SSEC_MPSP_SP1038 T_SHORT SP1038: Notch filter frequency 1 (76Hz -- O RW -32768 to 32767
-)
M_SSEC_MPSP_SP1039 T_SHORT SP1039: Lost motion compensation -- O RW -32768 to 32767
timing
M_SSEC_MPSP_SP1040 T_SHORT SP1040: Lost motion compensation 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1041 T_SHORT SP1041: Lost motion compensation 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1042 T_SHORT SP1042: Overshoot compensation 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1043 T_SHORT SP1043: Overshoot compensation 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1044 T_SHORT SP1044: Disturbance observer filter -- O RW -32768 to 32767
frequency
M_SSEC_MPSP_SP1045 T_SHORT SP1045: Disturbance observer gain -- O RW -32768 to 32767
M_SSEC_MPSP_SP1046 T_SHORT SP1046: Notch filter frequency 2 (76Hz -- O RW -32768 to 32767
-)
M_SSEC_MPSP_SP1047 T_SHORT SP1047: Inductive voltage -- O RW -32768 to 32767
compensation gain
M_SSEC_MPSP_SP1048 T_SHORT SP1048: Voltage non-sensitive band -- O RW -32768 to 32767
M_SSEC_MPSP_SP1049 T_SHORT SP1049: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1050 T_SHORT SP1050: Acceleration rate feed forward -- O RW -32768 to 32767
M_SSEC_MPSP_SP1051 T_SHORT SP1051: Dual FB control time constant -- O RW -32768 to 32767
M_SSEC_MPSP_SP1052 T_SHORT SP1052: Dual FB control non-sensitive -- O RW -32768 to 32767
band
M_SSEC_MPSP_SP1053 T_SHORT SP1053: Excessive error detection -- O RW -32768 to 32767
width (Speed mode)
M_SSEC_MPSP_SP1054 T_SHORT SP1054: Closed loop overrun detection -- O RW -32768 to 32767
width
M_SSEC_MPSP_SP1055 T_SHORT SP1055: EMG maximum delay time -- O RW -32768 to 32767
M_SSEC_MPSP_SP1056 T_SHORT SP1056: Deceleration control time -- O RW -32768 to 32767
constant
M_SSEC_MPSP_SP1057 T_SHORT SP1057: Spindle side gear 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1058 T_SHORT SP1058: Spindle side gear 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1059 T_SHORT SP1059: Spindle side gear 3 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1060 T_SHORT SP1060: Spindle side gear 4 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1061 T_SHORT SP1061: Motor side gear 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1062 T_SHORT SP1062: Motor side gear 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1063 T_SHORT SP1063: Motor side gear 3 -- O RW -32768 to 32767

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 160 of 206
inventcom

M_SSEC_MPSP_SP1064 T_SHORT SP1064: Motor side gear 4 -- O RW -32768 to 32767


M_SSEC_MPSP_SP1065 T_SHORT SP1065: Torque control 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1066 T_SHORT SP1066: Torque control 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1067 T_SHORT SP1067: Torque control 3 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1068 T_SHORT SP1068: Torque control 4 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1069 T_SHORT SP1069: Lower limit value of current -- O RW -32768 to 32767
reduction during acceleration
M_SSEC_MPSP_SP1070 T_SHORT SP1070: Break point speed of current -- O RW -32768 to 32767
reduction during acceleration
M_SSEC_MPSP_SP1071 T_SHORT SP1071: Lower limit value of current -- O RW -32768 to 32767
reduction during deceleration
M_SSEC_MPSP_SP1072 T_SHORT SP1072: Break point speed of current -- O RW -32768 to 32767
reduction during deceleration
M_SSEC_MPSP_SP1073 T_SHORT SP1073: Variable speed gain target -- O RW -32768 to 32767
value
M_SSEC_MPSP_SP1074 T_SHORT SP1074: Variable speed gain change -- O RW -32768 to 32767
start speed
M_SSEC_MPSP_SP1075 T_SHORT SP1075: Slip compensation scale of H -- O RW -32768 to 32767
coil in regeneration
M_SSEC_MPSP_SP1076 T_SHORT SP1076: Slip compensation scale of L -- O RW -32768 to 32767
coil in regeneration
M_SSEC_MPSP_SP1077 T_SHORT SP1077: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1078 T_SHORT SP1078: Temperature compensation -- O RW -32768 to 32767
function selection
M_SSEC_MPSP_SP1079 T_SHORT SP1079: Temperature compensation -- O RW -32768 to 32767
initial value
M_SSEC_MPSP_SP1080 T_SHORT SP1080: Temperature compensation -- O RW -32768 to 32767
iron-loss coefficient
M_SSEC_MPSP_SP1081 T_SHORT SP1081: Speed cancel coefficient -- O RW -32768 to 32767
M_SSEC_MPSP_SP1082 T_SHORT SP1082: Phase compensation time -- O RW -32768 to 32767
constant lower limit value
M_SSEC_MPSP_SP1083 T_SHORT SP1083: Phase compensation -- O RW -32768 to 32767
completion width
M_SSEC_MPSP_SP1084 T_SHORT SP1084: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1085 T_SHORT SP1085: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1086 T_SHORT SP1086: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1087 T_SHORT SP1087: Not used -- O RW -32768 to 32767

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 161 of 206
inventcom

M_SSEC_MPSP_SP1088 T_SHORT SP1088: Not used -- O RW -32768 to 32767


M_SSEC_MPSP_SP1089 T_SHORT SP1089: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1090 T_SHORT SP1090: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1091 T_SHORT SP1091: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1092 T_SHORT SP1092: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1093 T_SHORT SP1093: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1094 T_SHORT SP1094: Coil switch gate shut off timer -- O RW -32768 to 32767
M_SSEC_MPSP_SP1095 T_SHORT SP1095: Coil switch current limit timer -- O RW -32768 to 32767
M_SSEC_MPSP_SP1096 T_SHORT SP1096: Coil switch current limit value -- O RW -32768 to 32767
M_SSEC_MPSP_SP1097 T_SHORT SP1097:Q axis current lead -- O RW -32768 to 32767
compensation
M_SSEC_MPSP_SP1098 T_SHORT SP1098:D axis current lead -- O RW -32768 to 32767
compensation
M_SSEC_MPSP_SP1099 T_SHORT SP1099:Q axis current gain -- O RW -32768 to 32767
M_SSEC_MPSP_SP1100 T_SHORT SP1100:D axis current gain -- O RW -32768 to 32767
M_SSEC_MPSP_SP1101 T_SHORT SP1101:Q axis current lead -- O RW -32768 to 32767
compensation(L-coil)
M_SSEC_MPSP_SP1102 T_SHORT SP1102:D axis current lead -- O RW -32768 to 32767
compensation(L-coil)
M_SSEC_MPSP_SP1103 T_SHORT SP1103:Q axis current gain (L-coil) -- O RW -32768 to 32767
M_SSEC_MPSP_SP1104 T_SHORT SP1104:D axis current gain (L-coil) -- O RW -32768 to 32767
M_SSEC_MPSP_SP1105 T_SHORT SP1105:(Reserved for M-coil) -- O RW -32768 to 32767
M_SSEC_MPSP_SP1106 T_SHORT SP1106:(Reserved for M-coil) -- O RW -32768 to 32767
M_SSEC_MPSP_SP1107 T_SHORT SP1107:(Reserved for M-coil) -- O RW -32768 to 32767
M_SSEC_MPSP_SP1108 T_SHORT SP1108:(Reserved for M-coil) -- O RW -32768 to 32767
M_SSEC_MPSP_SP1109 T_SHORT SP1109: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1110 T_SHORT SP1110: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1111 T_SHORT SP1111: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1112 T_SHORT SP1112: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1113 T_SHORT SP1113: Current command value in -- O RW -32768 to 32767
open loop
M_SSEC_MPSP_SP1114 T_SHORT SP1114: Orientation pulse error check -- O RW -32768 to 32767
width
M_SSEC_MPSP_SP1115 T_SHORT SP1115:(Reserved for SPM Z phase -- O RW -32768 to 32767
position magnetic pole data)
M_SSEC_MPSP_SP1116 T_SHORT SP1116: Not used -- O RW -32768 to 32767

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 162 of 206
inventcom

M_SSEC_MPSP_SP1117 T_SHORT SP1117: Not used -- O RW -32768 to 32767


M_SSEC_MPSP_SP1118 T_SHORT SP1118: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1119 T_SHORT SP1119: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1120 T_SHORT SP1120: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1121 T_SHORT SP1121: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1122 T_SHORT SP1122: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1123 T_SHORT SP1123: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1124 T_SHORT SP1124: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1125 T_SHORT SP1125: DA output data No. channel 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1126 T_SHORT SP1126: DA output data No. channel 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1127 T_SHORT SP1127: DA output scale channel 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1128 T_SHORT SP1128: DA output scale channel 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1129 T_SHORT SP1129: H-coil motor constant 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1130 T_SHORT SP1130: H-coil motor constant 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1131 T_SHORT SP1131: H-coil motor constant 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1132 T_SHORT SP1132: H-coil motor constant 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1133 T_SHORT SP1133: H-coil motor constant 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1134 T_SHORT SP1134: H-coil motor constant 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1135 T_SHORT SP1135: H-coil motor constant 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1136 T_SHORT SP1136: H-coil motor constant 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1137 T_SHORT SP1137: H-coil motor constant 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1138 T_SHORT SP1138: H-coil motor constant 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1139 T_SHORT SP1139: H-coil motor constant 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1140 T_SHORT SP1140: H-coil motor constant 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1141 T_SHORT SP1141: H-coil motor constant 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1142 T_SHORT SP1142: H-coil motor constant 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1143 T_SHORT SP1143: H-coil motor constant 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1144 T_SHORT SP1144: H-coil motor constant 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1145 T_SHORT SP1145: H-coil motor constant 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1146 T_SHORT SP1146: H-coil motor constant 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1147 T_SHORT SP1147: H-coil motor constant 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1148 T_SHORT SP1148: H-coil motor constant 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1149 T_SHORT SP1149: H-coil motor constant 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1150 T_SHORT SP1150: H-coil motor constant 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1151 T_SHORT SP1151: H-coil motor constant 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1152 T_SHORT SP1152: H-coil motor constant 2 -- O RW -32768 to 32767

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 163 of 206
inventcom

M_SSEC_MPSP_SP1153 T_SHORT SP1153: H-coil motor constant 2 -- O RW -32768 to 32767


M_SSEC_MPSP_SP1154 T_SHORT SP1154: H-coil motor constant 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1155 T_SHORT SP1155: H-coil motor constant 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1156 T_SHORT SP1156: H-coil motor constant 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1157 T_SHORT SP1157: H-coil motor constant 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1158 T_SHORT SP1158: H-coil motor constant 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1159 T_SHORT SP1159: H-coil motor constant 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1160 T_SHORT SP1160: H-coil motor constant 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1161 T_SHORT SP1161: L-coil motor constant 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1162 T_SHORT SP1162: L-coil motor constant 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1163 T_SHORT SP1163: L-coil motor constant 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1164 T_SHORT SP1164: L-coil motor constant 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1165 T_SHORT SP1165: L-coil motor constant 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1166 T_SHORT SP1166: L-coil motor constant 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1167 T_SHORT SP1167: L-coil motor constant 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1168 T_SHORT SP1168: L-coil motor constant 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1169 T_SHORT SP1169: L-coil motor constant 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1170 T_SHORT SP1170: L-coil motor constant 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1171 T_SHORT SP1171: L-coil motor constant 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1172 T_SHORT SP1172: L-coil motor constant 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1173 T_SHORT SP1173: L-coil motor constant 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1174 T_SHORT SP1174: L-coil motor constant 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1175 T_SHORT SP1175: L-coil motor constant 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1176 T_SHORT SP1176: L-coil motor constant 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1177 T_SHORT SP1177: L-coil motor constant 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1178 T_SHORT SP1178: L-coil motor constant 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1179 T_SHORT SP1179: L-coil motor constant 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1180 T_SHORT SP1180: L-coil motor constant 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1181 T_SHORT SP1181: L-coil motor constant 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1182 T_SHORT SP1182: L-coil motor constant 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1183 T_SHORT SP1183: L-coil motor constant 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1184 T_SHORT SP1184: L-coil motor constant 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1185 T_SHORT SP1185: L-coil motor constant 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1186 T_SHORT SP1186: L-coil motor constant 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1187 T_SHORT SP1187: L-coil motor constant 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1188 T_SHORT SP1188: L-coil motor constant 2 -- O RW -32768 to 32767

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 164 of 206
inventcom

M_SSEC_MPSP_SP1189 T_SHORT SP1189: L-coil motor constant 2 -- O RW -32768 to 32767


M_SSEC_MPSP_SP1190 T_SHORT SP1190: L-coil motor constant 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1191 T_SHORT SP1191: L-coil motor constant 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1192 T_SHORT SP1192: L-coil motor constant 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP1193 T_SHORT SP1193: M-coil motor constant -- O RW -32768 to 32767
1(Reserved)
M_SSEC_MPSP_SP1194 T_SHORT SP1194: M-coil motor constant -- O RW -32768 to 32767
1(Reserved)
M_SSEC_MPSP_SP1195 T_SHORT SP1195: M-coil motor constant -- O RW -32768 to 32767
1(Reserved)
M_SSEC_MPSP_SP1196 T_SHORT SP1196: M-coil motor constant -- O RW -32768 to 32767
1(Reserved)
M_SSEC_MPSP_SP1197 T_SHORT SP1197: M-coil motor constant -- O RW -32768 to 32767
1(Reserved)
M_SSEC_MPSP_SP1198 T_SHORT SP1198: M-coil motor constant -- O RW -32768 to 32767
1(Reserved)
M_SSEC_MPSP_SP1199 T_SHORT SP1199: M-coil motor constant -- O RW -32768 to 32767
1(Reserved)
M_SSEC_MPSP_SP1200 T_SHORT SP1200: M-coil motor constant -- O RW -32768 to 32767
1(Reserved)
M_SSEC_MPSP_SP1201 T_SHORT SP1201: M-coil motor constant -- O RW -32768 to 32767
1(Reserved)
M_SSEC_MPSP_SP1202 T_SHORT SP1202: M-coil motor constant -- O RW -32768 to 32767
1(Reserved)
M_SSEC_MPSP_SP1203 T_SHORT SP1203: M-coil motor constant -- O RW -32768 to 32767
1(Reserved)
M_SSEC_MPSP_SP1204 T_SHORT SP1204: M-coil motor constant -- O RW -32768 to 32767
1(Reserved)
M_SSEC_MPSP_SP1205 T_SHORT SP1205: M-coil motor constant -- O RW -32768 to 32767
1(Reserved)
M_SSEC_MPSP_SP1206 T_SHORT SP1206: M-coil motor constant -- O RW -32768 to 32767
1(Reserved)
M_SSEC_MPSP_SP1207 T_SHORT SP1207: M-coil motor constant -- O RW -32768 to 32767
1(Reserved)
M_SSEC_MPSP_SP1208 T_SHORT SP1208: M-coil motor constant -- O RW -32768 to 32767
1(Reserved)

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 165 of 206
inventcom

M_SSEC_MPSP_SP1209 T_SHORT SP1209: M-coil motor constant -- O RW -32768 to 32767


2(Reserved)
M_SSEC_MPSP_SP1210 T_SHORT SP1210: M-coil motor constant -- O RW -32768 to 32767
2(Reserved)
M_SSEC_MPSP_SP1211 T_SHORT SP1211: M-coil motor constant -- O RW -32768 to 32767
2(Reserved)
M_SSEC_MPSP_SP1212 T_SHORT SP1212: M-coil motor constant -- O RW -32768 to 32767
2(Reserved)
M_SSEC_MPSP_SP1213 T_SHORT SP1213: M-coil motor constant -- O RW -32768 to 32767
2(Reserved)
M_SSEC_MPSP_SP1214 T_SHORT SP1214: M-coil motor constant -- O RW -32768 to 32767
2(Reserved)
M_SSEC_MPSP_SP1215 T_SHORT SP1215: M-coil motor constant -- O RW -32768 to 32767
2(Reserved)
M_SSEC_MPSP_SP1216 T_SHORT SP1216: M-coil motor constant -- O RW -32768 to 32767
2(Reserved)
M_SSEC_MPSP_SP1217 T_SHORT SP1217: M-coil motor constant -- O RW -32768 to 32767
2(Reserved)
M_SSEC_MPSP_SP1218 T_SHORT SP1218: M-coil motor constant -- O RW -32768 to 32767
2(Reserved)
M_SSEC_MPSP_SP1219 T_SHORT SP1219: M-coil motor constant -- O RW -32768 to 32767
2(Reserved)
M_SSEC_MPSP_SP1220 T_SHORT SP1220: M-coil motor constant -- O RW -32768 to 32767
2(Reserved)
M_SSEC_MPSP_SP1221 T_SHORT SP1221: M-coil motor constant -- O RW -32768 to 32767
2(Reserved)
M_SSEC_MPSP_SP1222 T_SHORT SP1222: M-coil motor constant -- O RW -32768 to 32767
2(Reserved)
M_SSEC_MPSP_SP1223 T_SHORT SP1223: M-coil motor constant -- O RW -32768 to 32767
2(Reserved)
M_SSEC_MPSP_SP1224 T_SHORT SP1224: M-coil motor constant -- O RW -32768 to 32767
2(Reserved)
M_SSEC_MPSP_SP1225 T_SHORT SP1225: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1226 T_SHORT SP1226: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1227 T_SHORT SP1227: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1228 T_SHORT SP1228: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1229 T_SHORT SP1229: Not used -- O RW -32768 to 32767

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 166 of 206
inventcom

M_SSEC_MPSP_SP1230 T_SHORT SP1230: Not used -- O RW -32768 to 32767


M_SSEC_MPSP_SP1231 T_SHORT SP1231: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1232 T_SHORT SP1232: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1233 T_SHORT SP1233: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1234 T_SHORT SP1234: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1235 T_SHORT SP1235: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1236 T_SHORT SP1236: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1237 T_SHORT SP1237: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1238 T_SHORT SP1238: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1239 T_SHORT SP1239: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1240 T_SHORT SP1240: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1241 T_SHORT SP1241: Not open for user -- O RW -32768 to 32767
M_SSEC_MPSP_SP1242 T_SHORT SP1242: Not open for user -- O RW -32768 to 32767
M_SSEC_MPSP_SP1243 T_SHORT SP1243: Not open for user -- O RW -32768 to 32767
M_SSEC_EXST_MDI_CLR_STS T_CHAR MDI clear complete O - RW 0 to 1, setting is only 0
M_SSEC_EXST_CONNECT_STS T_CHAR More than one network being O -- R 0 to 1
connected
M_SSEC_EXST_RAS_IMPOSITION T_UCHAR Imposition O -- R 0 to 1
M_SSEC_EXST_RAS_INTERLOCK_P T_LONG(BIT) Interlock (+) O -- R "00000000" to "11111111"
M_SSEC_EXST_RAS_INTERLOCK_N T_LONG(BIT) Interlock (-) O -- R "00000000" to "11111111"
M_SSEC_EXST_RAS_EXTDCC_P T_LONG(BIT) External deceleration (+) O -- R "00000000" to "11111111"
M_SSEC_EXST_RAS_EXTDCC_N T_LONG(BIT) External deceleration (-) O -- R "00000000" to "11111111"
M_SSEC_EXST_RAPID_OVERRIDE T_LONG Rapid traverse override O -- R 0 to 10000 (In increment of
1/100%)
M_SSEC_EXST_SCRN_REQ_UP T_UCHAR Rising edge signal of Y729 (screen -- -- RW 0 to 1, Setting is only 0
display request)
M_SSEC_EXST_SCRN_REQ_DOWN T_UCHAR Falling edge signal of Y729 (screen -- -- RW 0 to 1, Setting is only 0
display request)
M_SSEC_EXST_MACRO_ALM T_CHAR Macro alarm occurring O -- R 0 to 2, 1: #3000 occurring, 2:
#3006 occurring
M_SSEC_CCLK_BASE_ABNML_LINK3 T_CHAR 3rd slot Setting of data link faulty -- -- RW 0,1
station
M_SSEC_CCLK_BASE_PLC_STOP3 T_CHAR 3rd slot Setting at PLC STOP -- -- RW 0,1
M_SSEC_CCLK_BASE_OCCUP_BUREAUX3 T_CHAR 3rd slot Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BASE_CYCLIC3 T_CHAR 3rd slot Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BASE_CONNECT_NUM3 T_CHAR 3rd slot Number of connected modules -- -- RW 0 to 64

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 167 of 206
inventcom

M_SSEC_CCLK_BASE_RETRY3 T_CHAR 3rd slot Number of retries -- -- RW 0 to 7


M_SSEC_CCLK_BASE_AUTO_OPE_MATA3 T_CHAR 3rd slot Number of automatic return -- -- RW 0 to 10
modules
M_SSEC_CCLK_BASE_STANDBY_MASTER3 T_CHAR 3rd slot Standby master station -- -- RW 0 to 64
M_SSEC_CCLK_BASE_NC_DOWN3 T_CHAR 3rd slot Operation at NC down -- -- RW 0,1
M_SSEC_CCLK_BASE_SCAN_MODE3 T_CHAR 3rd slot Scan mode -- -- RW 0,1
M_SSEC_CCLK_BASE_DELAY_TIME3 T_CHAR 3rd slot Delay time -- -- RW Fixed to 0
M_SSEC_CCLK_BASE_RX_DEV3 T_CHAR 3rd slot Remote input (RX) refresh -- -- RW X,M,L,B,D,W,R
device name
M_SSEC_CCLK_BASE_RX_NO3 T_SHORT 3rd slot Remote input (RX) refresh -- -- RW Depends on the device name X0
device No. to X5FF M0 to M10239 L0 to
L511 B0 to B1FFF D0 to D2047
W0 to W1FFF R8300 to R9799
R9800 to R9899
M_SSEC_CCLK_BASE_RY_DEV3 T_CHAR 3rd slot Remote output (RY) refresh -- -- RW Y,M,L,B,D,W,R
device name
M_SSEC_CCLK_BASE_RY_NO3 T_SHORT 3rd slot Remote output (RY) refresh -- -- RW Depends on the device name Y0
device No. to Y5FF Others are the same with
RX
M_SSEC_CCLK_BASE_RWR_DEV3 T_CHAR 3rd slot Remote register (RWr) refresh -- -- RW M,L,B,D,W,R
device name
M_SSEC_CCLK_BASE_RWR_NO3 T_SHORT 3rd slot Remote register (RWr) refresh -- -- RW Depends on the device name The
device No. same with RX
M_SSEC_CCLK_BASE_RWW_DEV3 T_CHAR 3rd slot Remote register (RWw) refresh -- -- RW M,L,B,D,W,R
device name
M_SSEC_CCLK_BASE_RWW_NO3 T_SHORT 3rd slot Remote register (RWw) refresh -- -- RW Depends on the device name The
device No. same with RX
M_SSEC_CCLK_BASE_SB_DEV3 T_CHAR 3rd slot Special relay (SB) refresh -- -- RW M,L,B,D,W,R,SB
device name
M_SSEC_CCLK_BASE_SB_NO3 T_SHORT 3rd slot Special relay (SB) refresh -- -- RW Depends on the device name SB0
device No. to SB1FF Others are the same
with RX
M_SSEC_CCLK_BASE_SW_DEV3 T_CHAR 3rd slot Special relay (SW) refresh -- -- RW M,L,B,D,W,R,SW
device name
M_SSEC_CCLK_BASE_SW_NO3 T_SHORT 3rd slot Special relay (SW) refresh -- -- RW Depends on the device name
device No. SW0 to SW1FF Others are the
same with RX

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 168 of 206
inventcom

M_SSEC_CCLK_BASE_PRTCL_VER3 T_CHAR 3rd slot Protocol version -- -- RW 0,1


M_SSEC_MPSP_SP1244 T_SHORT SP1244: Not open for user -- O RW -32768 to 32767
M_SSEC_MPSP_SP1245 T_SHORT SP1245: Not open for user -- O RW -32768 to 32767
M_SSEC_MPSP_SP1246 T_SHORT SP1246: Not open for user -- O RW -32768 to 32767
M_SSEC_MPSP_SP1247 T_SHORT SP1247: Not open for user -- O RW -32768 to 32767
M_SSEC_MPSP_SP1248 T_SHORT SP1248: Not open for user -- O RW -32768 to 32767
M_SSEC_MPSP_SP1249 T_SHORT SP1249: Not open for user -- O RW -32768 to 32767
M_SSEC_MPSP_SP1250 T_SHORT SP1250: Not open for user -- O RW -32768 to 32767
M_SSEC_MPSP_SP1251 T_SHORT SP1251: Not open for user -- O RW -32768 to 32767
M_SSEC_MPSP_SP1252 T_SHORT SP1252: Not open for user -- O RW -32768 to 32767
M_SSEC_MPSP_SP1253 T_SHORT SP1253: Not open for user -- O RW -32768 to 32767
M_SSEC_MPSP_SP1254 T_SHORT SP1254: Not open for user -- O RW -32768 to 32767
M_SSEC_MPSP_SP1255 T_SHORT SP1255: Not open for user -- O RW -32768 to 32767
M_SSEC_MPSP_SP1256 T_SHORT SP1256: Not open for user -- O RW -32768 to 32767
M_SSEC_MPSP_SP1257 T_SHORT SP1257: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1258 T_SHORT SP1258: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1259 T_SHORT SP1259: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1260 T_SHORT SP1260: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1261 T_SHORT SP1261: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1262 T_SHORT SP1262: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1263 T_SHORT SP1263: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1264 T_SHORT SP1264: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1265 T_SHORT SP1265: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1266 T_SHORT SP1266: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1267 T_SHORT SP1267: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1268 T_SHORT SP1268: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1269 T_SHORT SP1269: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1270 T_SHORT SP1270: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1271 T_SHORT SP1271: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1272 T_SHORT SP1272: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1273 T_SHORT SP1273: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1274 T_SHORT SP1274: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1275 T_SHORT SP1275: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1276 T_SHORT SP1276: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1277 T_SHORT SP1277: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1278 T_SHORT SP1278: Not used -- O RW -32768 to 32767

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 169 of 206
inventcom

M_SSEC_MPSP_SP1279 T_SHORT SP1279: Not used -- O RW -32768 to 32767


M_SSEC_MPSP_SP1280 T_SHORT SP1280: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1281 T_SHORT SP1281: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1282 T_SHORT SP1282: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1283 T_SHORT SP1283: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1284 T_SHORT SP1284: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1285 T_SHORT SP1285: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1286 T_SHORT SP1286: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1287 T_SHORT SP1287: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1288 T_SHORT SP1288: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1289 T_SHORT SP1289: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1290 T_SHORT SP1290: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1291 T_SHORT SP1291: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1292 T_SHORT SP1292: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1293 T_SHORT SP1293: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1294 T_SHORT SP1294: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1295 T_SHORT SP1295: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1296 T_SHORT SP1296: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1297 T_SHORT SP1297: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1298 T_SHORT SP1298: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1299 T_SHORT SP1299: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1300 T_SHORT SP1300: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1301 T_SHORT SP1301: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1302 T_SHORT SP1302: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1303 T_SHORT SP1303: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1304 T_SHORT SP1304: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1305 T_SHORT SP1305: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1306 T_SHORT SP1306: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1307 T_SHORT SP1307: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1308 T_SHORT SP1308: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1309 T_SHORT SP1309: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1310 T_SHORT SP1310: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1311 T_SHORT SP1311: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1312 T_SHORT SP1312: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1313 T_SHORT SP1313: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1314 T_SHORT SP1314: Not used -- O RW -32768 to 32767

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 170 of 206
inventcom

M_SSEC_MPSP_SP1315 T_SHORT SP1315: Not used -- O RW -32768 to 32767


M_SSEC_MPSP_SP1316 T_SHORT SP1316: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1317 T_SHORT SP1317: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1318 T_SHORT SP1318: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1319 T_SHORT SP1319: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1320 T_SHORT SP1320: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1321 T_SHORT SP1321: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1322 T_SHORT SP1322: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1323 T_SHORT SP1323: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1324 T_SHORT SP1324: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1325 T_SHORT SP1325: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1326 T_SHORT SP1326: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1327 T_SHORT SP1327: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1328 T_SHORT SP1328: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1329 T_SHORT SP1329: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1330 T_SHORT SP1330: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1331 T_SHORT SP1331: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1332 T_SHORT SP1332: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1333 T_SHORT SP1333: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1334 T_SHORT SP1334: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1335 T_SHORT SP1335: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1336 T_SHORT SP1336: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1337 T_SHORT SP1337: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1338 T_SHORT SP1338: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1339 T_SHORT SP1339: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1340 T_SHORT SP1340: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1341 T_SHORT SP1341: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1342 T_SHORT SP1342: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1343 T_SHORT SP1343: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1344 T_SHORT SP1344: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1345 T_SHORT SP1345: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1346 T_SHORT SP1346: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1347 T_SHORT SP1347: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1348 T_SHORT SP1348: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1349 T_SHORT SP1349: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1350 T_SHORT SP1350: Not used -- O RW -32768 to 32767

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 171 of 206
inventcom

M_SSEC_MPSP_SP1351 T_SHORT SP1351: Not used -- O RW -32768 to 32767


M_SSEC_MPSP_SP1352 T_SHORT SP1352: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1353 T_SHORT SP1353: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1354 T_SHORT SP1354: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1355 T_SHORT SP1355: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1356 T_SHORT SP1356: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1357 T_SHORT SP1357: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1358 T_SHORT SP1358: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1359 T_SHORT SP1359: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1360 T_SHORT SP1360: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1361 T_SHORT SP1361: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1362 T_SHORT SP1362: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1363 T_SHORT SP1363: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1364 T_SHORT SP1364: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1365 T_SHORT SP1365: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1366 T_SHORT SP1366: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1367 T_SHORT SP1367: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1368 T_SHORT SP1368: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1369 T_SHORT SP1369: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1370 T_SHORT SP1370: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1371 T_SHORT SP1371: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1372 T_SHORT SP1372: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1373 T_SHORT SP1373: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1374 T_SHORT SP1374: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1375 T_SHORT SP1375: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1376 T_SHORT SP1376: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1377 T_SHORT SP1377: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1378 T_SHORT SP1378: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1379 T_SHORT SP1379: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1380 T_SHORT SP1380: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1381 T_SHORT SP1381: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1382 T_SHORT SP1382: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1383 T_SHORT SP1383: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP1384 T_SHORT SP1384: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP046 T_SHORT SP046: Speed command dual cushion -- O RW -32768 to 32767
M_SSEC_MPSP_SP047 T_SHORT SP047: Speed detection reset value -- O RW -32768 to 32767

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 172 of 206
inventcom

M_SSEC_MPSP_SP048 T_SHORT SP048: Speed reach range -- O RW -32768 to 32767


M_SSEC_MPSP_SP049 T_SHORT SP049: Torque limit 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP050 T_SHORT SP050: Torque limit 3 -- O RW -32768 to 32767
M_SSEC_MPSP_SP051 T_SHORT SP051: Torque limit 4 (Not used) -- O RW -32768 to 32767
M_SSEC_MPSP_SP052 T_SHORT SP052: Torque limit 5 (Not used) -- O RW -32768 to 32767
M_SSEC_MPSP_SP053 T_SHORT SP053: Torque limit 6 (Not used) -- O RW -32768 to 32767
M_SSEC_MPSP_SP054 T_SHORT SP054: Torque limit 7 (Not used) -- O RW -32768 to 32767
M_SSEC_MPSP_SP055 T_SHORT SP055: Excessive speed deviation -- O RW -32768 to 32767
timer
M_SSEC_MPSP_SP056 T_SHORT SP056: Variable excitation (min value) -- O RW -32768 to 32767
M_SSEC_MPSP_SP057 T_SHORT SP057: Switch speed for excess -- O RW -32768 to 32767
M_SSEC_MPSP_SP058 T_SHORT SP058: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP059 T_SHORT SP059: Coil switch base shut timer -- O RW -32768 to 32767
M_SSEC_MPSP_SP060 T_SHORT SP060: Current limit timer after coil -- O RW -32768 to 32767
switch
M_SSEC_MPSP_SP061 T_SHORT SP061: Current limit value -- O RW -32768 to 32767
M_SSEC_MPSP_SP062 T_SHORT SP062: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP063 T_SHORT SP063: Overload alarm detection time -- O RW -32768 to 32767
M_SSEC_MPSP_SP064 T_SHORT SP064: Overload alarm detection level -- O RW -32768 to 32767
M_SSEC_MPSP_SP065 T_SHORT SP065: Target value of variable speed -- O RW -32768 to 32767
loop proportional gain
M_SSEC_MPSP_SP066 T_SHORT SP066: Change starting speed of -- O RW -32768 to 32767
variable speed loop proportional gain
M_SSEC_MPSP_SP067 T_SHORT SP067: Change starting speed of -- O RW -32768 to 32767
variable current loop gain
M_SSEC_MPSP_SP068 T_SHORT SP068: Change ending speed of -- O RW -32768 to 32767
variable current loop gain
M_SSEC_MPSP_SP069 T_SHORT SP069: Target value of variable current -- O RW -32768 to 32767
loop gain
M_SSEC_MPSP_SP070 T_SHORT SP070: Machine resonance -- O RW -32768 to 32767
suppression filter frequency
M_SSEC_MPSP_SP071 T_SHORT SP071: Fixed control constant -- O RW -32768 to 32767
M_SSEC_MPSP_SP072 T_SHORT SP072: Fixed control constant -- O RW -32768 to 32767
M_SSEC_MPSP_SP073 T_SHORT SP073: Fixed control constant -- O RW -32768 to 32767
M_SSEC_MPSP_SP074 T_SHORT SP074: Fixed control constant -- O RW -32768 to 32767
M_SSEC_MPSP_SP075 T_SHORT SP075: Fixed control constant -- O RW -32768 to 32767

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 173 of 206
inventcom

M_SSEC_MPSP_SP076 T_SHORT SP076: Machine resonance -- O RW -32768 to 32767


suppression filter performance speed
M_SSEC_MPSP_SP077 T_SHORT SP077: Td time selection -- O RW -32768 to 32767
M_SSEC_MPSP_SP078 T_SHORT SP078: Fixed control constant -- O RW -32768 to 32767
M_SSEC_MPSP_SP079 T_SHORT SP079: Fixed control constant -- O RW -32768 to 32767
M_SSEC_MPSP_SP080 T_SHORT SP080: Fixed control constant -- O RW -32768 to 32767
M_SSEC_MPSP_SP081 T_SHORT SP081: Fixed control constant -- O RW -32768 to 32767
M_SSEC_MPSP_SP082 T_SHORT SP082: Fixed control constant -- O RW -32768 to 32767
M_SSEC_MPSP_SP083 T_SHORT SP083: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP084 T_SHORT SP084: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP085 T_SHORT SP085: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP086 T_SHORT SP086: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP087 T_SHORT SP087: Target value of variable torque -- O RW -32768 to 32767
limit magnification at deceleration
M_SSEC_MPSP_SP088 T_SHORT SP088: Speed for starting change of -- O RW -32768 to 32767
variable torque limit magnification at
deceleration
M_SSEC_MPSP_SP089 T_SHORT SP089: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP090 T_SHORT SP090: Deceleration detector pulse -- O RW -32768 to 32767
tolerable error value
M_SSEC_MPSP_SP091 T_SHORT SP091: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP092 T_SHORT SP092: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP093 T_SHORT SP093: Position detector pulse -- O RW -32768 to 32767
tolerable error value
M_SSEC_MPSP_SP094 T_SHORT SP094: Load meter output filter -- O RW -32768 to 32767
M_SSEC_MPSP_SP095 T_SHORT SP095: The average number of times -- O RW -32768 to 32767
of speed FB
M_SSEC_MPSP_SP096 T_SHORT SP096: Encoder gear ratio -- O RW -32768 to 32767
M_SSEC_MPSP_SP097 T_SHORT SP097: Orientation specification -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP098 T_SHORT SP098: Orientation-mode speed loop -- O RW -32768 to 32767
gain proportional term
M_SSEC_MPSP_SP099 T_SHORT SP099: Orientation-mode speed loop -- O RW -32768 to 32767
gain integral time
M_SSEC_MPSP_SP100 T_SHORT SP100: Orientation-mode speed loop -- O RW -32768 to 32767
gain delay lead term

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 174 of 206
inventcom

M_SSEC_MPSP_SP101 T_SHORT SP101: Orientation advance in-position -- O RW -32768 to 32767


width
M_SSEC_MPSP_SP102 T_SHORT SP102: Excessive error value in -- O RW -32768 to 32767
orientation-mode
M_SSEC_MPSP_SP103 T_SHORT SP103: Index positioning completion -- O RW -32768 to 32767
OFF time timer
M_SSEC_MPSP_SP104 T_SHORT SP104: Torque limit value for -- O RW -32768 to 32767
orientation servo locking
M_SSEC_MPSP_SP105 T_SHORT SP105: Current loop gain magnification -- O RW -32768 to 32767
1 in orientation-mode
M_SSEC_MPSP_SP106 T_SHORT SP106: Current loop gain magnification -- O RW -32768 to 32767
2 in orientation-mode
M_SSEC_MPSP_SP107 T_SHORT SP107: Deceleration rate 2 in -- O RW -32768 to 32767
orientation-mode
M_SSEC_MPSP_SP108 T_SHORT SP108: Deceleration rate 3 in -- O RW -32768 to 32767
orientation-mode
M_SSEC_MPSP_SP109 T_SHORT SP109: Deceleration rate 4 in -- O RW -32768 to 32767
orientation-mode
M_SSEC_MPSP_SP110 T_SHORT SP110: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP111 T_SHORT SP111: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP112 T_SHORT SP112: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP113 T_SHORT SP113: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP114 T_SHORT SP114: Orientation pulse miss check -- O RW -32768 to 32767
value
M_SSEC_MPSP_SP115 T_SHORT SP115: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP116 T_SHORT SP116: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP117 T_SHORT SP117: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP118 T_SHORT SP118: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP119 T_SHORT SP119: Position gain H coil -- O RW -32768 to 32767
compensation magnification in
orientation-mode
M_SSEC_MPSP_SP120 T_SHORT SP120: Position gain L coil -- O RW -32768 to 32767
compensation magnification in
orientation-mode
M_SSEC_MPSP_SP121 T_SHORT SP121: Deceleration rate H coil -- O RW -32768 to 32767
compensation magnification in
orientation-mode

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 175 of 206
inventcom

M_SSEC_MPSP_SP122 T_SHORT SP122: Deceleration rate L coil -- O RW -32768 to 32767


compensation magnification in
orientation-mode
M_SSEC_MPSP_SP123 T_SHORT SP123: Magnet detector output peak -- O RW -32768 to 32767
value
M_SSEC_MPSP_SP124 T_SHORT SP124: Magnet detector linear zone -- O RW -32768 to 32767
width
M_SSEC_MPSP_SP125 T_SHORT SP125: Magnet detector switch point -- O RW -32768 to 32767
M_SSEC_MPSP_SP126 T_SHORT SP126: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP127 T_SHORT SP127: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP128 T_SHORT SP128: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP129 T_SHORT SP129: C axis specification -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP130 T_SHORT SP130: 1st position loop gain during C -- O RW -32768 to 32767
axis cutting
M_SSEC_MPSP_SP131 T_SHORT SP131: 2nd position loop gain during C -- O RW -32768 to 32767
axis cutting
M_SSEC_MPSP_SP132 T_SHORT SP132: 3rd position loop gain during C -- O RW -32768 to 32767
axis cutting
M_SSEC_MPSP_SP133 T_SHORT SP133: Stop position loop gain during C -- O RW -32768 to 32767
axis cutting
M_SSEC_MPSP_SP134 T_SHORT SP134: Speed loop gain proportional -- O RW -32768 to 32767
item during C axis not cutting
M_SSEC_MPSP_SP135 T_SHORT SP135: Speed loop gain integral item -- O RW -32768 to 32767
during C axis not cutting
M_SSEC_MPSP_SP136 T_SHORT SP136: Speed loop gain delay lead item -- O RW -32768 to 32767
during C axis not cutting
M_SSEC_MPSP_SP137 T_SHORT SP137: 1st speed loop gain proportional -- O RW -32768 to 32767
item during C axis cutting
M_SSEC_MPSP_SP138 T_SHORT SP138: 1st speed loop gain integral -- O RW -32768 to 32767
item during C axis cutting
M_SSEC_MPSP_SP139 T_SHORT SP139: 1st speed loop gain delay lead -- O RW -32768 to 32767
item during C axis cutting
M_SSEC_MPSP_SP140 T_SHORT SP140: 2nd speed loop gain -- O RW -32768 to 32767
proportional item during C axis cutting
M_SSEC_MPSP_SP141 T_SHORT SP141: 2nd speed loop gain integral -- O RW -32768 to 32767
item during C axis cutting

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 176 of 206
inventcom

M_SSEC_MPSP_SP142 T_SHORT SP142: 2nd speed loop gain delay lead -- O RW -32768 to 32767
item during C axis cutting
M_SSEC_MPSP_SP143 T_SHORT SP143: 3rd speed loop gain -- O RW -32768 to 32767
proportional item during C axis cutting
M_SSEC_MPSP_SP144 T_SHORT SP144: 3rd speed loop gain integral -- O RW -32768 to 32767
item during C axis cutting
M_SSEC_MPSP_SP145 T_SHORT SP145: 3rd speed loop gain delay lead -- O RW -32768 to 32767
item during C axis cutting
M_SSEC_MPSP_SP146 T_SHORT SP146: Speed loop gain proportional -- O RW -32768 to 32767
item for stop during C axis cutting
M_SSEC_MPSP_SP147 T_SHORT SP147: Speed loop gain integral item -- O RW -32768 to 32767
for stop during C axis cutting
M_SSEC_MPSP_SP148 T_SHORT SP148: Speed loop gain delay lead item -- O RW -32768 to 32767
for stop during C axis cutting
M_SSEC_MPSP_SP149 T_SHORT SP149: C axis reference position speed -- O RW -32768 to 32767
M_SSEC_MPSP_SP150 T_SHORT SP150: C axis reference position -- O RW -32768 to 32767
deceleration point
M_SSEC_MPSP_SP151 T_SHORT SP151: C axis reference position return -- O RW 0x0000 to 0xFFFF
shift amount (low byte)
M_SSEC_MPSP_SP152 T_SHORT SP152: C axis reference position return -- O RW 0x0000 to 0xFFFF
shift amount (high byte)
M_SSEC_MPSP_SP153 T_SHORT SP153: C axis in-position width -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP154 T_SHORT SP154: Excessive error width on C axis -- O RW 0x0000 to 0xFFFF
(low byte)
M_SSEC_MPSP_SP155 T_SHORT SP155: Excessive error width on C axis -- O RW 0x0000 to 0xFFFF
(high byte)
M_SSEC_MPSP_SP156 T_SHORT SP156: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP157 T_SHORT SP157: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP158 T_SHORT SP158: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP159 T_SHORT SP159: Variable excitation ratio during -- O RW -32768 to 32767
C axis not cutting
M_SSEC_MPSP_SP160 T_SHORT SP160: Variable excitation ratio during -- O RW -32768 to 32767
C axis not cutting
M_SSEC_MPSP_SP161 T_SHORT SP161: Current loop gain magnification -- O RW -32768 to 32767
1 during C axis not cutting
M_SSEC_MPSP_SP162 T_SHORT SP162: Current loop gain magnification -- O RW -32768 to 32767
2 during C axis not cutting

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 177 of 206
inventcom

M_SSEC_MPSP_SP163 T_SHORT SP163: Current loop gain magnification -- O RW -32768 to 32767


1 during C axis not cutting
M_SSEC_MPSP_SP164 T_SHORT SP164: Current loop gain magnification -- O RW -32768 to 32767
2 during C axis not cutting
M_SSEC_MPSP_SP165 T_SHORT SP165: C axis position loop gain 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP166 T_SHORT SP166: C axis position loop gain 3 -- O RW -32768 to 32767
M_SSEC_MPSP_SP167 T_SHORT SP167: Position loop gain for increased -- O RW -32768 to 32767
spindle holding force
M_SSEC_MPSP_SP168 T_SHORT SP168: Speed loop gain proportional -- O RW -32768 to 32767
term for increased spindle holding force
M_SSEC_MPSP_SP169 T_SHORT SP169: Speed loop gain integral item -- O RW -32768 to 32767
for increased spindle holding force
M_SSEC_MPSP_SP170 T_SHORT SP170: Speed loop gain delay lead item -- O RW -32768 to 32767
for increased spindle holding force
M_SSEC_MPSP_SP171 T_SHORT SP171: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP172 T_SHORT SP172: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP173 T_SHORT SP173: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP174 T_SHORT SP174: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP175 T_SHORT SP175: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP176 T_SHORT SP176: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP177 T_SHORT SP177: Spindle synchronization -- O RW 0x0000 to 0xFFFF
specification
M_SSEC_MPSP_SP178 T_SHORT SP178: Spindle synchronization speed -- O RW -32768 to 32767
loop gain proportional term
M_SSEC_MPSP_SP179 T_SHORT SP179: Spindle synchronization speed -- O RW -32768 to 32767
loop gain integral term
M_SSEC_MPSP_SP180 T_SHORT SP180: Spindle synchronization speed -- O RW -32768 to 32767
loop gain delay lead term
M_SSEC_MPSP_SP181 T_SHORT SP181: Spindle synchronization target -- O RW -32768 to 32767
value of variable speed loop
proportional gain
M_SSEC_MPSP_SP182 T_SHORT SP182: Spindle synchronization change -- O RW -32768 to 32767
starting speed of variable speed loop
proportional gain
M_SSEC_MPSP_SP183 T_SHORT SP183: Spindle synchronization sync -- O RW -32768 to 32767
matching speed
M_SSEC_MPSP_SP184 T_SHORT SP184: Not used -- O RW -32768 to 32767

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 178 of 206
inventcom

M_SSEC_MPSP_SP185 T_SHORT SP185: Spindle synchronization in- -- O RW -32768 to 32767


position width
M_SSEC_MPSP_SP186 T_SHORT SP186: Spindle synchronization -- O RW -32768 to 32767
excessive error value
M_SSEC_MPSP_SP187 T_SHORT SP187: Spindle synchronization current -- O RW -32768 to 32767
loop gain magnification 1
M_SSEC_MPSP_SP188 T_SHORT SP188: Spindle synchronization current -- O RW -32768 to 32767
loop gain magnification 2
M_SSEC_MPSP_SP189 T_SHORT SP189: Spindle synchronization position -- O RW -32768 to 32767
loop gain 2
M_SSEC_MPSP_SP190 T_SHORT SP190: Spindle synchronization position -- O RW -32768 to 32767
loop gain 3
M_SSEC_MPSP_SP191 T_SHORT SP191: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP192 T_SHORT SP192: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP193 T_SHORT SP193: Synchronized tapping -- O RW 0x0000 to 0xFFFF
specification
M_SSEC_MPSP_SP194 T_SHORT SP194: Synchronized tapping speed -- O RW -32768 to 32767
loop gain proportional term
M_SSEC_MPSP_SP195 T_SHORT SP195: Synchronized tapping speed -- O RW -32768 to 32767
loop gain integral term
M_SSEC_MPSP_SP196 T_SHORT SP196: Synchronized tapping speed -- O RW -32768 to 32767
loop gain delay lead term
M_SSEC_MPSP_SP197 T_SHORT SP197: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP198 T_SHORT SP198: Synchronized tapping target -- O RW -32768 to 32767
value of variable speed loop
proportional gain
M_SSEC_MPSP_SP199 T_SHORT SP199: Synchronized tapping change -- O RW -32768 to 32767
starting speed of variable speed loop
proportional gain
M_SSEC_MPSP_SP200 T_SHORT SP200: Synchronized tapping -- O RW -32768 to 32767
acceleration feed forward gain (gear 1)
M_SSEC_MPSP_SP201 T_SHORT SP201: Synchronized tapping -- O RW -32768 to 32767
acceleration feed forward gain (gear 2)
M_SSEC_MPSP_SP202 T_SHORT SP202: Synchronized tapping -- O RW -32768 to 32767
acceleration feed forward gain (gear 3)
M_SSEC_MPSP_SP203 T_SHORT SP203: Synchronized tapping -- O RW -32768 to 32767
acceleration feed forward gain (gear 4)

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 179 of 206
inventcom

M_SSEC_MPSP_SP204 T_SHORT SP204: Not used -- O RW -32768 to 32767


M_SSEC_MPSP_SP205 T_SHORT SP205: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP206 T_SHORT SP206: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP207 T_SHORT SP207: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP208 T_SHORT SP208: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP209 T_SHORT SP209: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP210 T_SHORT SP210: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP211 T_SHORT SP211: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP212 T_SHORT SP212: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP213 T_SHORT SP213: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP214 T_SHORT SP214: Synchronized tapping reference -- O RW -32768 to 32767
position return speed
M_SSEC_MPSP_SP215 T_SHORT SP215: Synchronized tapping reference -- O RW -32768 to 32767
position return deceleration point
M_SSEC_MPSP_SP216 T_SHORT SP216: Synchronized tapping reference -- O RW -32768 to 32767
position return shift amount
M_SSEC_MPSP_SP217 T_SHORT SP217: Synchronized tapping in- -- O RW -32768 to 32767
position width
M_SSEC_MPSP_SP218 T_SHORT SP218: Synchronized tapping excessive -- O RW -32768 to 32767
error value
M_SSEC_MPSP_SP219 T_SHORT SP219: Synchronized tapping current -- O RW -32768 to 32767
loop gain magnification 1
M_SSEC_MPSP_SP220 T_SHORT SP220: Synchronized tapping current -- O RW -32768 to 32767
loop gain magnification 2
M_SSEC_MPSP_SP221 T_SHORT SP221: Synchronized tapping position -- O RW -32768 to 32767
loop gain 2
M_SSEC_MPSP_SP222 T_SHORT SP222: Synchronized tapping position -- O RW -32768 to 32767
loop gain 3
M_SSEC_MPSP_SP223 T_SHORT SP223: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP224 T_SHORT SP224: Not used -- O RW -32768 to 32767
M_SSEC_BASEPRM_LKYOKOL T_FLOATBIN/T_LONG Coordinate rotation vector (Horizontal O - RW ±99999.999
axis)
M_SSEC_BASEPRM_LKTATEL T_FLOATBIN/T_LONG Coordinate rotation vector (Vertical axis) O - RW ±99999.999
M_SSEC_BASEPRM_LKKAKUDO T_DOUBLE Coordinate rotation angle O - RW ±360.000
M_SSEC_BASEPRM_TOOL_LEN T_FLOATBIN/T_LONG Tool length O -- RW ±99999.999
M_SSEC_BASEPRM_TOOL_DIA T_FLOATBIN/T_LONG Tool diameter O -- RW ±99999.999

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 180 of 206
inventcom

M_SSEC_BASEPRM_OFFSET_X T_FLOATBIN/T_LONG Centre offset amount X O -- RW ±99999.999


M_SSEC_BASEPRM_OFFSET_Y T_FLOATBIN/T_LONG Centre offset amount Y O -- RW ±99999.999
M_SSEC_BASEPRM_RETURN T_FLOATBIN/T_LONG Return amount O -- RW 0 to 99999.999
M_SSEC_BASEPRM_FEED T_LONG Feedrate O -- RW 1 to 60000
M_SSEC_BASEPRM_SKIP_PAST_H T_FLOATBIN/T_LONG Skip past amount (Horizontal axis) O -- RW ±99999.999
M_SSEC_BASEPRM_SKIP_PAST_V T_FLOATBIN/T_LONG Skip past amount (Vertical axis) O -- RW ±99999.999
M_SSEC_BASEPRM_WORK_SIN_CHG T_CHAR External workpiece sign reverse O -- RW 0,1
M_SSEC_BASEPRM_WORK_INVA T_CHAR External workpiece offset invalid O -- RW 0,1
M_SSEC_BASEPRM_TLM_L_MEAS_AXIS T_STR Tool length measure axis O -- RW 2 letters (1st letter is 'A' to 'Z',
2nd letter is 'A' to 'Z','0' to '9')
M_SSEC_BASEPRM_TLM_M_MEAS_AXIS T_STR Tool diameter measure axis O -- RW 2 letters (1st letter is 'A' to 'Z',
2nd letter is 'A' to 'Z','0' to '9')
M_SSEC_BASEPRM_D0DEV T_STR Sub-pro storage destination D0:dev -- -- R Within 4 letters (5 letters including
NULL which follows ": ")
M_SSEC_BASEPRM_D0DIR T_STR Sub-pro storage destination D0:dir -- -- R Within 55 letters (56 letters
including NULL)
M_SSEC_BASEPRM_D1DEV T_STR Sub-pro storage destination D1:dev -- -- R Within 4 letters (5 letters including
NULL which follows ": ")
M_SSEC_BASEPRM_D1DIR T_STR Sub-pro storage destination D1:dir -- -- R Within 55 letters (56 letters
including NULL)
M_SSEC_BASEPRM_D2DEV T_STR Sub-pro storage destination D2:dev -- -- R Within 4 letters (5 letters including
NULL which follows ": ")
M_SSEC_BASEPRM_D2DIR T_STR Sub-pro storage destination D2:dir -- -- R Within 55 letters (56 letters
including NULL)
M_SSEC_BASEPRM_D3DEV T_STR Sub-pro storage destination D3:dev -- -- R Within 4 letters (5 letters including
NULL which follows ": ")
M_SSEC_BASEPRM_D3DIR T_STR Sub-pro storage destination D3:dir -- -- R Within 55 letters (56 letters
including NULL)
M_SSEC_BASEPRM_D4DEV T_STR Sub-pro storage destination D4:dev -- -- R Within 4 letters (5 letters including
NULL which follows ": ")
M_SSEC_BASEPRM_D4DIR T_STR Sub-pro storage destination D4:dir -- -- R Within 55 letters (56 letters
including NULL)
M_SSEC_BASEPRM_G_CODE_FORMAT T_LONG G code format -- -- RW 0 to 2
M_SSEC_BASEPRM_M2_LABEL_O T_LONG M2 label O -- -- RW 0,1
M_SSEC_BASEPRM_M2_MACRO_CONVERT T_LONG M2 macro converter enabled -- -- RW 0,1
M_SSEC_BASEPRM_COORD_ANGL Coordinate rotation angle

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 181 of 206
inventcom

M_SSEC_BASEPRM_COORD_ROT_CENTER_H T_FLOATBIN/T_LONG Coordinate rotation centre coordinate O -- RW ±99999.999


(H)
M_SSEC_BASEPRM_COORD_ROT_CENTER_V T_FLOATBIN/T_LONG Coordinate rotation centre coordinate O -- RW ±99999.999
(V)
M_SSEC_BASEPRM_PASSWD T_LONG Machine tool builder macro password -- -- RW 2 to 99999999
M_SSEC_BASEPRM_M3MPAR1 T_CHAR Parameter for M3/L3 (m3mpar1) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_OPERAT1 T_CHAR operat1 -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_OPERAT2 T_CHAR operat2 -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_OPERAT3 T_CHAR operat3 -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_OPERAT5 T_CHAR operat5 -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_OPERAT7 T_CHAR operat7 -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_MASMAC5 T_CHAR masmac5 -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_CHRCOMP T_FLOATBIN/T_LONG Relative error after conversion and O -- R -99.999
before interpolation (Determined by
#8019)
M_SSEC_BASEPRM_CHRCOMP2 T_FLOATBIN/T_LONG Relative error after conversion and O -- R -999999.999
before interpolation in corner accuracy
factor (Determined by #8023)
M_SSEC_BASEPRM_APC_TYPE T_CHAR APC screen display type selection -- -- RW 0: Standard, 1: Pallet 4-page
registration
M_SSEC_BASEPRM_VALID_PALLET_NUM T_CHAR Number of pallets setting -- -- RW 2 to 12
M_SSEC_BASEPRM_APLC T_CHAR APLC enabled/disabled (APLC enabled) -- -- RW 0,1
M_SSEC_BASEPRM_PLCAUTO T_CHAR PLC start timing selection (PLCautorun -- -- RW 0,1
enabled)
M_SSEC_BASEPRM_HD_IPADDR T_STR IP address of the PC in which -- -- RW 0.0.0.0 to 255.255.255.255
machining programs are stored
M_SSEC_BASEPRM_HD_PORTNUMBER T_LONG Port No. of the PC in which machining -- -- RW 0 to 65535
programs are stored
M_SSEC_BASEPRM_HD_TIMEOUT T_SHORT Time out setting of the PC in which -- -- RW 0 to 300
machining programs are stored
M_SSEC_BASEPRM_HD_CACHE T_SHORT Cache setting fo HD operation - - RW 0 to 1024
M_SSEC_BASEPRM_SW_KEYBOARD T_CHAR Software keyboard - - RW 0,1
M_SSEC_BASEPRM_HANDYTERMINAL_PW T_STR Handy terminal password - - RW Blank or 4-digit numeric
M_SSEC_BASEPRM_AX16MD T_CHAR Connecting 16 axes for 1ch - - RW 0,1
M_SSEC_BASEPRM_3D_MCHK T_CHAR 3D machine collision check disabled - - RW 0,1
M_SSEC_BASEPRM_CHK_LEN1 T_FLOATBIN 1st-step collision check distance - - RW 0.000 to 99999.999(mm)

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 182 of 206
inventcom

M_SSEC_BASEPRM_CHK_LEN2 T_FLOATBIN 2nd-step collision check distance - - RW 0.000 to 99999.999(mm)


M_SSEC_BASEPRM_EXPAND_RATE T_SHORT 3D machine collision check shape - - RW 0 to 300(%)
expansion rate
M_SSEC_BASEPRM_TOFS_RUNNING T_CHAR Tool compensation amount setting - - RW 0,1
during automatic operation enabled (T-
ofs set at run)
M_SSEC_BASEPRM_M_PW_HOLD T_CHAR Machine user password hold - - RW 0,1
M_SSEC_BASEPRM_2SYS_DISPLAY T_CHAR 2-part system simultaneous display - - RW 0,1
M_SSEC_BASEPRM_PLC_MESG_TYPE T_CHAR Format of PLC alarm and operator - - RW 0,1
message (PLC mesg disp type)
M_SSEC_BASEPRM_G33_1_DRN T_LONG G33.1 Dry run - - RW 0,1
M_SSEC_BASEPRM_G33_1_FHD T_LONG G33.1 Feed hold - - RW 0,1
M_SSEC_BASEPRM_TOLE_ARC_CENT T_FLOATBIN/T_DOUBLE Tolerable correction value of arc center - - RW -1.000 to 0.100
error
M_SSEC_BASEPRM_ARC_TO_G1 T_UCHAR Change command from arc to linear - - RW 0,1
when no arc center designation
M_SSEC_BASEPRM_MANTAPSYNCCANCL T_UCHAR Synchronization cancel during manual - -- RW 0,1
synchronous tapping
M_SSEC_BASEPRM_CURSOR_POS_SRCH T_CHAR Cursor position search - - RW 0 to 2
M_SSEC_BASEPRM_MBTANAXH T_STR Manual feed rate B constant surface O - RW 2 digits
control intersecting part system axis
name (horizontal)
M_SSEC_BASEPRM_MBTANAXV T_STR Manual feed rate B constant surface O - RW 2 digits
control intersecting part system axis
name (vertical)
M_SSEC_BASEPRM_MBROTCH T_FLOATBIN/T_DOUBLE Manual feed rate B constant surface O - RW -99999.999 to 99999.999
control rotation center machine position
(horizontal)
M_SSEC_BASEPRM_MBROTCV T_FLOATBIN/T_DOUBLE Manual feed rate B constant surface O - RW -99999.999 to 99999.999
control rotation center machine position
(vertical)
M_SSEC_BASEPRM_MFIG T_CHAR Number of M O - RW 1 to 4
M_SSEC_BASEPRM_MBIN T_CHAR M binary O - RW -1/0/1
M_SSEC_BASEPRM_SFIG T_CHAR Number of S O - RW 1 to 4
M_SSEC_BASEPRM_SBIN T_CHAR S binary O - RW -1/0/1
M_SSEC_BASEPRM_TFIG T_CHAR Number of T O - RW 1 to 4
M_SSEC_BASEPRM_TBIN T_CHAR T binary O - RW -1/0/1

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 183 of 206
inventcom

M_SSEC_BASEPRM_BFIG T_CHAR Number of B O - RW 1 to 4


M_SSEC_BASEPRM_BBIN T_CHAR B binary O - RW -1/0/1
M_SSEC_BASEPRM_G33_1_ROT_NAME T_STR G33.1 Rotary axis name O - RW A to Z
M_SSEC_BASEPRM_G33_1_OVR T_SHORT G33.1 Override O - RW 0 to 6
M_SSEC_BASEPRM_SYNTAP_SCANCEL T_LONG Synchronous tapping (,S) cancel -- - RW 0,1
M_SSEC_BASEPRM_ZEROPOINT_MARK T_LONG Display position of zero point mark -- - RW 0,1
M_SSEC_BASEPRM_PRGCRDROT_TYPE T_LONG PRG coordinate rotation type -- - RW 0,1
M_SSEC_BASEPRM_G33_1_CUTUP_SPD T_LONG G33.1 Chamfering speed O - RW 1 to 1000000
M_SSEC_BASEPRM_MBRSTDR1 T_FLOATBIN/T_DOUBLE Surface speed control standard radius 1 O - RW 0 to 99999.999
M_SSEC_BASEPRM_MBRSTDF1 T_DOUBLE Surface speed control standard speed 1 O - RW 1 to 1000000
M_SSEC_BASEPRM_MBRSTDR2 T_FLOATBIN/T_DOUBLE Surface speed control standard radius 2 O - RW 0 to 99999.999
M_SSEC_BASEPRM_MBRSTDF2 T_DOUBLE Surface speed control standard speed 2 O - RW 1 to 1000000
M_SSEC_MSP_ALM_HIST_TM3 T_LONG Alarm history 3 (Time) -- O RW 0x00 to 0xFF
M_SSEC_MSP_ALM_HIST_TM4 T_LONG Alarm history 4 (Time) -- O RW 0x00 to 0xFF
M_SSEC_MSP_ALM_HIST_TM5 T_LONG Alarm history 5 (Time) -- O RW 0x00 to 0xFF
M_SSEC_MSP_ALM_HIST_TM6 T_LONG Alarm history 6 (Time) -- O RW 0x00 to 0xFF
M_SSEC_MSP_ALM_HIST_TM7 T_LONG Alarm history 7 (Time) -- O RW 0x00 to 0xFF
M_SSEC_MSP_ALM_HIST_TM8 T_LONG Alarm history 8 (Time) -- O RW 0x00 to 0xFF
M_SSEC_MSP_ALM_HIST_NO1 T_CHAR Alarm history 1 (Alarm No.) -- O RW 0x00 to 0xFF
M_SSEC_MSP_ALM_HIST_NO2 T_CHAR Alarm history 2 (Alarm No.) -- O RW 0x00 to 0xFF
M_SSEC_MSP_ALM_HIST_NO3 T_CHAR Alarm history 3 (Alarm No.) -- O RW 0x00 to 0xFF
M_SSEC_MSP_ALM_HIST_NO4 T_CHAR Alarm history 4 (Alarm No.) -- O RW 0x00 to 0xFF
M_SSEC_MSP_ALM_HIST_NO5 T_CHAR Alarm history 5 (Alarm No.) -- O RW 0x00 to 0xFF
M_SSEC_MSP_ALM_HIST_NO6 T_CHAR Alarm history 6 (Alarm No.) -- O RW 0x00 to 0xFF
M_SSEC_MSP_ALM_HIST_NO7 T_CHAR Alarm history 7 (Alarm No.) -- O RW 0x00 to 0xFF
M_SSEC_MSP_ALM_HIST_NO8 T_CHAR Alarm history 8 (Alarm No.) -- O RW 0x00 to 0xFF
M_SSEC_MSP_MNT1 T_STR Maintenance history (MNT1) -- O R
M_SSEC_MSP_MNT2 T_STR Maintenance history (MNT2) -- O R
M_SSEC_MSP_MNT3 T_STR Maintenance history (MNT3) -- O R
M_SSEC_MSP_MNT4 T_STR Maintenance history (MNT4) -- O R
M_SSEC_MSP_SYS T_STR /SYS -- O R
M_SSEC_MSP_CMD1 T_STR / T_LONG Control input 1 -- O R
M_SSEC_MSP_CMD2 T_STR / T_LONG Control input 2 -- O R
M_SSEC_MSP_CMD3 T_STR / T_LONG Control input 3 -- O R
M_SSEC_MSP_CMD4 T_STR / T_LONG Control input 4 -- O R
M_SSEC_MSP_STS1 T_STR / T_LONG Control output 1 -- O R

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 184 of 206
inventcom

M_SSEC_MSP_STS2 T_STR / T_LONG Control output 2 -- O R


M_SSEC_MSP_STS3 T_STR / T_LONG Control output 3 -- O R
M_SSEC_MSP_STS4 T_STR / T_LONG Control output 4 -- O R
M_SSEC_MSP_SPNDL_ANGL T_DOUBLE Spindle angle -- O R
M_SSEC_MSP_CMD5L T_LONG Control input 5L -- O R -32768 to 32767
M_SSEC_MSP_CMD5H T_LONG Control input 5H -- O R -32768 to 32767
M_SSEC_MSP_CMD6L T_LONG Control input 6L -- O R -32768 to 32767
M_SSEC_MSP_CMD6H T_LONG Control input 6H -- O R -32768 to 32767
M_SSEC_MSP_STS5L T_LONG Control output 5L -- O R -32768 to 32767
M_SSEC_MSP_STS5H T_LONG Control output 5H -- O R -32768 to 32767
M_SSEC_MSP_STS6L T_LONG Control output 6L -- O R -32768 to 32767
M_SSEC_MSP_STS6H T_LONG Control output 6H -- O R -32768 to 32767
M_SSEC_MSP_CMD5 T_STR / T_LONG Control input 5 -- O R -32768 to 32767
M_SSEC_MSP_CMD6 T_STR / T_LONG Control input 6 -- O R -32768 to 32767
M_SSEC_MSP_STS5 T_STR / T_LONG Control output 5 -- O R -32768 to 32767
M_SSEC_MSP_STS6 T_STR / T_LONG Control output 6 -- O R -32768 to 32767
M_SSEC_MSP_ALM_CLR T_CHAR Alarm history clear -- O W 0
M_SSEC_MSP_FEED T_LONG Feedrate -- O R
M_SSEC_MSP_MAX_CUR1 T_SHORT MAX current 1 -- O R
M_SSEC_MSP_MAX_CUR2 T_SHORT MAX current 2 -- O R
M_SSEC_MSP_MAX_CUR3 T_SHORT MAX current 3 -- O R
M_SSEC_MSP_OVER_LOAD T_SHORT Overload -- O R
M_SSEC_MSP_OVER_REG T_SHORT Regenerative load -- O R
M_SSEC_MSP_EST_DTORQ T_SHORT Estimated disturbance torque -- O R
M_SSEC_MSP_MAX_DTORQ T_SHORT MAX disturbance torque -- O R
M_SSEC_MSP_LOAD_INER T_SHORT Load inertia ratio -- O R
M_SSEC_MSP_AFLT_FREQ T_SHORT AFLT frequency -- O R
M_SSEC_MSP_AFLT_GAIN T_SHORT AFLT gain -- O R
M_SSEC_MSP_GRDSP T_FLOATBIN/T_LONG Grind interval -- O R
M_SSEC_MSP_GRID T_FLOATBIN/T_LONG Grid amount -- O R
M_SSEC_MSP_MAC_POS T_FLOATBIN/T_LONG Machine position -- O R
M_SSEC_MSP_MOT_POS T_FLOATBIN/T_LONG Motor end FB -- O R
M_SSEC_MSP_FB_ERROR T_LONG FB error -- O R
M_SSEC_MSP_DFB_COMP T_LONG DFB compensation amount -- O R
M_SSEC_MSP_MOT_DT_NO T_STR Serial No. of motor end encoder -- O R
M_SSEC_MSP_MAC_DT_NO T_STR Serial No. of machine end encoder -- O R

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 185 of 206
inventcom

M_SSEC_MSP_TAPERR_WIDE T_FLOATBIN/T_LONG Synchronous tapping width error (Max -- O R ±99999.999


value)
M_SSEC_MSP_TAPERR_ANGLE T_FLOATBIN/T_LONG Synchronous tapping angle error (Max -- O R ±99999.999
value)
M_SSEC_MSP_SP_TEMPERATURE T_SHORT Spindle thermister temperature -- O R
M_SSEC_MSP_ALM_NO(x) T_CHAR Alarm No. (x=1 to 32) -- O W 0
M_SSEC_MSP_ALM_TIMES(x) T_LONG The number of times of alarm (x=1 to -- O RW (Setting is only 0)
32)
M_SSEC_MSP_DA_ADDRESS1 T_LONG DA address 1 -- O R 0000 to FFFF
M_SSEC_MSP_DA_OUTPUT1 T_LONG DA output 1 -- O R
M_SSEC_MSP_DA_ADDRESS2 T_LONG DA address 2 -- O R 0000 to FFFF
M_SSEC_MSP_DA_OUTPUT2 T_LONG DA output 2 -- O R
M_SSEC_MSP_ALM_TIMES_CLR T_CHAR Clear all the number of times of alarms -- O W 0
M_SSEC_HWCFG_RAS_BATTERY_USED T_LONG Used years of battery -- -- R/W â– Other than T_STR (Ten-fold
value is returned) 25--> 2.5 years
â– T_STR "2.5"-->2.5 years
*Setting is only 0
M_SSEC_HWCFG_RAS_MAIN_UNIT_TEMP T_STR/T_LONG Control unit temperature -- -- R â– Other than T_STR 1000-fold
value of temperature (deg) -
12500-->-12.5 deg â– T_STR -12.5
--> -12.5 deg
M_SSEC_HWCFG_RAS_MAIN_UNIT_FAN_REV T_LONG The number of revolutions of control -- -- R T_STR: 1 digit below decimal
unit fan point Other than T_STR: 1000-fold
data
M_SSEC_HWCFG_RAS_MAIN_UNIT_TEMP2 T_STR/T_LONG Control unit temperature 2 -- -- R â– Other than T_STR 1000-fold
value of temperature (deg) -
12500-->-12.5 deg â– T_STR -12.5
--> -12.5 deg
M_SSEC_HWCFG_RAS_SV_COMERR_NOS T_LONG Servo communication error 1 the -- -- R 0 to 2147483647
number of times
M_SSEC_HWCFG_RAS_SV_COMERR_ACC T_LONG Servo communication error 1 the -- -- R/W 0 to 2147483647 *Setting is only
accumulated number of times 0
M_SSEC_HWCFG_RAS_RIO_COMERR_NOS T_LONG RIO communication error the number -- -- R 0 to 2147483647
of times
M_SSEC_HWCFG_RAS_RIO_COMERR_ACC T_LONG RIO communication error the -- -- R/W 0 to 2147483647 *Setting is only
accumulated number of times 0
M_SSEC_HWCFG_RAS_RIO_CHNODE1 T_STR RIO channel No./Station No. 1 -- -- R

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 186 of 206
inventcom

M_SSEC_HWCFG_RAS_RIO_CHNODE2 T_STR RIO channel No./Station No. 2 -- -- R/W 0: Clear


M_SSEC_HWCFG_RAS_ETHER_COMERR_NO T_LONG Ethernet communication error the -- -- R 0 to 2147483647
S number of times
M_SSEC_HWCFG_RAS_ETHER_COMERR_AC T_LONG Ethernet communication error the -- -- R/W 0 to 2147483647 *Setting is only
C accumulated number of times 0
M_SSEC_HWCFG_RAS_SV_ERR_NOS(x) T_LONG Servo communication error the number -- -- R 0 to 2147483647
of times (x=1 to 8)
M_SSEC_HWCFG_RAS_SV_ERR_ACC(x) T_LONG Servo communication error the -- -- R/W 0 to 2147483647 *Setting is only
accumulated number of times (x=1 to 0
8)
M_SSEC_HWCFG_CREDIT_STAUTS T_CHAR Credit system status -- -- R 0: Disabled, 1: Enabled
M_SSEC_HWCFG_CREDIT_TIMELIMIT T_STR Time limit of credit system -- -- R
M_SSEC_HWCFG_CCLINK_STATUS T_CHAR CC-Link status -- -- R 0: Disabled, 1: Enabled
M_SSEC_SMP_PRM_AT_SMP_AXNO T_LONG Target axis No. (For auto tuning) -- -- RW 0 to Max number of enable d axes
M_SSEC_SMP_PRM_AT_MSIG_RATE T_SHORT M sys vibration sampling frequency - - R/W 0 to 4
(For auto tuning)
M_SSEC_SMP_PRM_STOP_DELAY T_LONG Stop delay time -- -- RW 0 to 1000000
M_SSEC_SMP_PRM_SAMPLING_NOS T_LONG The number of pieces of sampling data -- -- R --
M_SSEC_SMP_PRM_SMP_STS T_SHORT Sampling status -- -- R 0: Stopping sampling 1: Waiting
for trigger 2: Executing sampling
3: Preparing to stop (during
sampling)
M_SSEC_BASEPRM_HANACDC T_CHAR Time constant 0 for handle feed O -- RW 0 to 9
M_SSEC_BASEPRM_MMACSET T_CHAR Macro call for M command O -- RW 0,1
M_SSEC_BASEPRM_SMACSET T_CHAR Macro call for S command O -- RW 0,1
M_SSEC_BASEPRM_TMACSET T_CHAR Macro call for T command O -- RW 0,1
M_SSEC_BASEPRM_BMACSET T_CHAR Macro call with 2nd miscellaneous O -- RW 0,1
code
M_SSEC_BASEPRM_SSELEC T_CHAR Select initial spindle control O -- RW 0,1
M_SSEC_BASEPRM_G0ACC T_CHAR Validate acceleration and deceleration O -- RW 0,1
with inclination angle constant G0
M_SSEC_BASEPRM_G1ACC T_CHAR Validate acceleration and deceleration O -- RW 0,1
with inclination angle constant G1
M_SSEC_BASEPRM_MIROFS T_LONG Distance between facing turrets O -- RW 0 to 99999.999
M_SSEC_BASEPRM_TMIRS1 T_LONG Select turrets as facing turrets with T O -- RW 0x00000000 to 0xFFFFFFFF
command 1

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 187 of 206
inventcom

M_SSEC_BASEPRM_TMIRS2 T_LONG Select turrets as facing turrets with T O -- RW 0x00000000 to 0xFFFFFFFF


command 2
M_SSEC_BASEPRM_G0BDCC T_CHAR Before G0 interpolation O -- RW 0,1
M_SSEC_BASEPRM_G1BF T_LONG Maximum speed O -- RW 1 to 1000000
M_SSEC_BASEPRM_G1BTL T_SHORT Time constant O -- RW 1 to 5000
M_SSEC_BASEPRM_MRCK T_DOUBLE Arc radius error compensation factor O -- RW -60.0 to 20.0
M_SSEC_BASEPRM_CIRDEC T_LONG Arc deceleration speed O -- RW 1 to 1000000
M_SSEC_BASEPRM_RSTGMD T_LONG Modal G code reset O -- RW 0x00000000 to 0x7FFFFFFF
M_SSEC_BASEPRM_FHTYP T_CHAR Feed hold stop type O -- RW 0 to 2
M_SSEC_BASEPRM_FHNO T_LONG Feed hold external signal device O -- RW 0x000 to 0x13F
M_SSEC_BASEPRM_PROAXY T_FLOATBIN/T_LONG Side 1 of inclination angle O -- RW ±9999.999
M_SSEC_BASEPRM_MACAXY T_FLOATBIN/T_LONG Side 2 of inclination angle O -- RW ±9999.999
M_SSEC_BASEPRM_MACAXX T_FLOATBIN/T_LONG Side 3 of inclination angle O -- RW ±9999.999
M_SSEC_BASEPRM_EXTDCC T_LONG External deceleration level O -- RW 1 to 1000000
M_SSEC_BASEPRM_AUX01 T_STR/T_LONG aux01 (Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_AUX02 T_STR/T_LONG aux02 -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_AUX03 T_STR/T_LONG aux03 -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_AUX04 T_STR/T_LONG aux04 -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_AUX05 T_STR/T_LONG aux05 (Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_AUX06 T_STR/T_LONG aux06 -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_AUX07 T_STR/T_LONG aux07 -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_AUX08 T_STR/T_LONG aux08 (Do not use) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_AUX09 T_STR/T_LONG aux09 -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_AUX10 T_STR/T_LONG aux10 -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_AUX11 T_STR/T_LONG aux11 -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_AUX12 T_STR/T_LONG aux12 -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_SET01 T_STR/T_LONG set01 -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_SET02 T_STR/T_LONG set02 (Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_SET03 T_STR/T_LONG set03 (Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_SET04 T_STR/T_LONG set04 (Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_SET05 T_STR/T_LONG set05 (Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_SET06 T_STR/T_LONG set06 -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_SET07 T_STR/T_LONG set07 (Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_SET08 T_STR/T_LONG set08 -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_SET09 T_STR/T_LONG set09 -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_SET10 T_STR/T_LONG set10 (Not used) -- -- RW 0x00 to 0xFF

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 188 of 206
inventcom

M_SSEC_BASEPRM_SET11 T_STR/T_LONG set11 -- -- RW 0x00 to 0xFF


M_SSEC_BASEPRM_SET12 T_STR/T_LONG set12 -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_SET13 T_STR/T_LONG set13(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_SET14 T_STR/T_LONG set14(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_SET15 T_STR/T_LONG set15(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_SET16 T_STR/T_LONG set16(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_SET17 T_STR/T_LONG set17(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_SET18 T_STR/T_LONG set18 -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_SET19 T_STR/T_LONG set19(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_SET20 T_STR/T_LONG set20(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_SET21 T_STR/T_LONG set21(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_SET22 T_STR/T_LONG set22(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_SET23 T_STR/T_LONG set23(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_SET24 T_STR/T_LONG set24(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_SET25 T_STR/T_LONG set25(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_SET26 T_STR/T_LONG set26(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_SET27 T_STR/T_LONG set27(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_SET28 T_STR/T_LONG set28(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_SET29 T_STR/T_LONG set29(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_SET30 T_STR/T_LONG set30(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_SET31 T_STR/T_LONG set31(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_SET32 T_STR/T_LONG set32(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_SET33 T_STR/T_LONG set33(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_SET34 T_STR/T_LONG set34(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_SET35 T_STR/T_LONG set35(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_SET36 T_STR/T_LONG set36(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_EXT01 T_STR/T_LONG ext01 -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_EXT02 T_STR/T_LONG ext02(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_EXT03 T_STR/T_LONG ext03 -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_EXT04 T_STR/T_LONG ext04(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_EXT05 T_STR/T_LONG ext05(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_EXT06 T_STR/T_LONG ext06(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_EXT07 T_STR/T_LONG ext07 -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_EXT08 T_STR/T_LONG ext08(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_EXT09 T_STR/T_LONG ext09(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_EXT10 T_STR/T_LONG ext10(Not used) -- -- RW 0x00 to 0xFF

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 189 of 206
inventcom

M_SSEC_BASEPRM_EXT11 T_STR/T_LONG ext11(Not used) -- -- RW 0x00 to 0xFF


M_SSEC_BASEPRM_EXT12 T_STR/T_LONG ext12(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_EXT13 T_STR/T_LONG ext13 -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_EXT14 T_STR/T_LONG ext14(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_EXT15 T_STR/T_LONG ext15(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_EXT16 T_STR/T_LONG ext16(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_EXT17 T_STR/T_LONG ext17(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_EXT18 T_STR/T_LONG ext18(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_EXT19 T_STR/T_LONG ext19(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_EXT20 T_STR/T_LONG ext20(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_EXT21 T_STR/T_LONG ext21(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_EXT22 T_STR/T_LONG ext22(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_EXT23 T_STR/T_LONG ext23 -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_EXT24 T_STR/T_LONG ext24(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_EXT25 T_STR/T_LONG ext25(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_EXT26 T_STR/T_LONG ext26(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_EXT27 T_STR/T_LONG ext27(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_EXT28 T_STR/T_LONG ext28(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_EXT29 T_STR/T_LONG ext29(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_EXT30 T_STR/T_LONG ext30(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_EXT31 T_STR/T_LONG ext31(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_EXT32 T_STR/T_LONG ext32(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_EXT33 T_STR/T_LONG ext33(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_EXT34 T_STR/T_LONG ext34(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_EXT35 T_STR/T_LONG ext35(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_EXT36 T_STR/T_LONG ext36(Not used) -- -- RW 0x00 to 0xFF
M_SSEC_BASEPRM_NRFCHK T_CHAR Origin neighboring check method -- -- RW 0 to 2
M_SSEC_BASEPRM_RETPRG T_LONG Automatic return by program restart -- -- RW 0,1
M_SSEC_BASEPRM_V1COM_N T_SHORT No. of #100 address part system -- -- RW 0 to 100
common variables
M_SSEC_BASEPRM_V0COM_N T_SHORT No. of #500 address part system -- -- RW 0 to 500
common variables
M_SSEC_BASEPRM_INPSTYP T_CHAR Deceleration check specification type -- -- RW 0,1
(InpsTyp)
M_SSEC_BASEPRM_GTYPE T_SHORT Model switch (Gtype) -- -- RW 0,1

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 190 of 206
inventcom

M_SSEC_BASEPRM_WT_MMIN T_LONG Timing synchronization M code -- -- RW 100 to 99999999


(Minimum) 0,100 to 99999999
M_SSEC_BASEPRM_WT_MMAX T_LONG Timing synchronization M code -- -- RW 100 to 99999999
(Maximum) 0,100 to 99999999
M_SSEC_BASEPRM_TBASE T_LONG Tool life management standard number -- -- RW 0 to 9999
M_SSEC_BASEPRM_TAPDWL T_SHORT Synchronous tap hole bottom wait time -- -- RW 0 to 999
M_SSEC_BASEPRM_TAPINP T_SHORT Synchronous tap in-position check -- -- RW 0 to 32767
width (tap axis)
M_SSEC_BASEPRM_CROSSCOM T_UCHAR Reference of common variables -- -- RW 0 to 1
common for part
systems (CrossCom)
M_SSEC_BASEPRM_CHOP_R T_SHORT Chopping compensation amount -- -- RW 1900 to 2782
memory area R register head No.
(chop_R)
M_SSEC_BASEPRM_PLC_CONST_EXT T_SHORT PLC constant extension number - - R/W 0 to 750
M_SSEC_BASEPRM_3D_ATC_TYPE T_CHAR 3D tool change method -- -- RW 0 to 2
M_SSEC_BASEPRM_TLM_TYPE T_CHAR TLM type -- -- RW 0 to 1
M_SSEC_BASEPRM_EMGCNT T_UCHAR Emergency stop contactor shut-off -- -- RW 0 to 60
time
M_SSEC_BASEPRM_MCDP1 T_SHORT Contactor weld detection device 1 -- -- RW 0000 to 02FF
M_SSEC_BASEPRM_MCDP2 T_SHORT Contactor weld detection device 2 -- -- RW 0000 to 02FF
M_SSEC_BASEPRM_F_BUS_INIT_DELAY T_CHAR Fieldbus communication error invalid -- -- RW 0 to 255
time
M_SSEC_BASEPRM_LMC_RESTRAIN T_CHAR Lost motion compensation restraint in -- -- RW 0 to 1
handle mode
M_SSEC_BASEPRM_DIDOREFRESH T_CHAR DI/DO refresh cycle -- -- RW 0 to 2
M_SSEC_BASEPRM_MAN_SMG T_UCHAR Manual feed acceleration/deceleration -- -- RW 0 to 1
selection
M_SSEC_BASEPRM_N400VALTYPE T_UCHAR #400 address variable type -- -- RW 0 to 1
M_SSEC_BASEPRM_REVSVTRG T_CHAR Trigger switching to save arbitrary -- -- RW 0 to 1
reverse run data
M_SSEC_BASEPRM_MCDP3 T_SHORT Contactor weld detection device 3 -- -- RW 0000 to 02FF
M_SSEC_BASEPRM_SSC_RIO T_UCHAR Safety observation remote I/O -- -- RW 0 to 1
connection
M_SSEC_BASEPRM_DOOR1 T_SHORT Door 1 switch input device -- -- RW 0000 to 02FF
M_SSEC_BASEPRM_DOOR2 T_SHORT Door 2 switch input device -- -- RW 0000 to 02FF
M_SSEC_BASEPRM_MCCT1 T_SHORT Contactor shut-off output 1 device -- -- RW 0000 to 02FF

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 191 of 206
inventcom

M_SSEC_BASEPRM_MCCT2 T_SHORT Contactor shut-off output 2 device -- -- RW 0000 to 02FF


M_SSEC_BASEPRM_MCCT3 T_SHORT Contactor shut-off output 3 device -- -- RW 0000 to 02FF
M_SSEC_BASEPRM_MCHKT1 T_LONG Contactor operation check allowance -- -- RW 0 to 30000
time 1
M_SSEC_BASEPRM_MCHKT2 T_LONG Contactor operation check allowance -- -- RW 0 to 30000
time 2
M_SSEC_BASEPRM_MCHKT3 T_LONG Contactor operation check allowance -- -- RW 0 to 30000
time 3
M_SSEC_BASEPRM_PLCUNIT T_STR PLC unit O - RW A,B,C,D,E
M_SSEC_BASEPRM_PLCPLCUNIT T_STR PLC unit (PLC) - - RW A,B,C,D,E
M_SSEC_BASEPRM_MCMPUNIT T_STR Machine error compensation unit O - RW A,B,C,D,E
M_SSEC_BASEPRM_PLCMCMPUNIT T_STR Machine error compensation unit (PLC) - - RW A,B,C,D,E
M_SSEC_BASEPRM_SYSTEMTYPE T_CHAR Machine type selection - - RW M,L
M_SSEC_BASEPRM_NORIOCHK T_BIT Disable RIO-not-connected detection - - RW 0 to 1
M_SSEC_BASEPRM_ATS T_CHAR ATS function enabled - - RW 0 to 1
M_SSEC_BASEPRM_AUX_ACC T_CHAR Auxiliary axis constant inclination - - RW 0 to 1
M_SSEC_BASEPRM_POLYAX T_CHAR Rotary tool axis number O -- RW 0 to 8
M_SSEC_BASEPRM_G0IPFG T_CHAR G1-->G0 deceleration check O -- RW 0,1
M_SSEC_BASEPRM_G1IPFG T_CHAR G1-->G1 deceleration check O -- RW 0,1
M_SSEC_BASEPRM_CKREF2 T_CHAR Second reference position return check O -- RW 0,1
M_SSEC_BASEPRM_F1FM T_LONG Upper limit of F1 digit feedrate O -- RW 0 to 60000
M_SSEC_BASEPRM_F1CONST T_SHORT F1 digit feedrate change constant O -- RW 0 to 32767
M_SSEC_BASEPRM_DOORH T_CHAR Shorten door interlock II axis stop time O -- RW 0,1
M_SSEC_BASEPRM_DOORPM T_LONG Signal input device 1 for door interlock O -- RW 0x000 to 0x100
II by each part system
M_SSEC_BASEPRM_DOORPS T_LONG Signal input device 2 for door interlock O -- RW 0x000 to 0x100
II by each part system
M_SSEC_BASEPRM_STAPM T_LONG M code for synchronous tap selection O -- RW 0 to 99999999
M_SSEC_BASEPRM_EXP_LINAX T_STR Exponential function interpolation linear O -- RW Axis name
axis ('A' to 'Z')
M_SSEC_BASEPRM_EXP_ROTAX T_STR Exponential function interpolation rotary O -- RW Axis name
axis ('A' to 'Z')
M_SSEC_BASEPRM_MILL_AX T_STR Lathe milling rotary axis No. O -- RW Axis name
M_SSEC_BASEPRM_MILL_C T_CHAR Lathe milling rotary axis name 0: Y axis O -- RW 0: Y axis 1: C axis
1: C axis
M_SSEC_BASEPRM_POLM T_CHAR Spindle polygon base axis No. O -- RW 0 to 8

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 192 of 206
inventcom

M_SSEC_BASEPRM_POLS T_CHAR Spindle polygon synchronous axis No. O -- RW 0 to 8


M_SSEC_BASEPRM_TCHG34 T_CHAR Additional axis tool compensation O -- RW 0,1
operation
M_SSEC_BASEPRM_C_MIN T_FLOATBIN/T_LONG Minimum turning angle (C_min) O -- RW 0 to 360.000
M_SSEC_BASEPRM_C_AXIS T_CHAR Normal line control axis (C_axis) O -- RW 1 to 8
M_SSEC_BASEPRM_C_FEED T_LONG Normal line control axis turning speed O -- RW 1 to 1000000
(C_feed)
M_SSEC_BASEPRM_C_TYPE T_LONG Normal line control type (C_type) O -- RW 0,1
M_SSEC_BASEPRM_MILL_PAX T_STR Milling linear axis name O -- RW Axis name
M_SSEC_BASEPRM_SNG44_1 T_CHAR Spindle No. for G44.1 command O -- RW 0 to 4
M_SSEC_BASEPRM_C_LENG T_FLOATBIN/T_LONG Minimum turning movement amount O -- RW 0 to 99999.999
(C_leng)
M_SSEC_BASEPRM_CRS_AX1 T_STR Cross machining control axis with 1st O -- RW Axis name
axis
M_SSEC_BASEPRM_CRS_AX2 T_STR Cross machining control axis with 2nd O -- RW Axis name
axis
M_SSEC_BASEPRM_CRS_AX3 T_STR Cross machining control axis with 3rd O -- RW Axis name
axis
M_SSEC_BASEPRM_CRS_AX4 T_STR Cross machining control axis with 4th O -- RW Axis name
axis
M_SSEC_BASEPRM_CRS_AX5 T_STR Cross machining control axis with 5th O -- RW Axis name
axis
M_SSEC_BASEPRM_CRS_AX6 T_STR Cross machining control axis with 6th O -- RW Axis name
axis
M_SSEC_BASEPRM_CRS_AX7 T_STR Cross machining control axis with 7th O -- RW Axis name
axis
M_SSEC_BASEPRM_CRS_AX8 T_STR Cross machining control axis with 8th O -- RW Axis name
axis
M_SSEC_BASEPRM_3DCDC T_LONG Switch workpiece coordinate display O -- RW 0,1
during 3D coordinate conversion
M_SSEC_BASEPRM_3DREMC T_LONG Switch remaining command display O -- RW 0,1
during 3D coordinate conversion
M_SSEC_BASEPRM_3DCDRC T_LONG Switch coordinate reading during 3D O -- RW 0,1
coordinate conversion
M_SSEC_BASEPRM_3DSPD T_LONG Hole drilling speed during 3D O -- RW 0 to 1000000
coordinate conversion
M_SSEC_BASEPRM_HELGEAR T_STR Helical machining base axis O -- RW A to Z

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 193 of 206
inventcom

M_SSEC_BASEPRM_3DSPDSLCT T_LONG Switch drill axis's mode from rapid O -- RW 0,1


traverse during 3D coordinate
M_SSEC_BASEPRM_SFILTG1 T_LONG G01 soft acceleration/deceleration filter O -- RW 0 to 200
M_SSEC_BASEPRM_SFILTG0 T_LONG G00 soft acceleration/deceleration filter O -- RW 0 to 200
M_SSEC_BASEPRM_SFILT2 T_LONG Soft acceleration/deceleration filter 2 O -- RW 0 to 50
M_SSEC_BASEPRM_SSSDIS T_LONG SSS control adjustment coefficient O -- RW 0,1
fixed value selection
M_SSEC_BASEPRM_CIRORP T_CHAR Arc command overlap O -- RW 0,1
M_SSEC_BASEPRM_RET1 T_UCHAR Return type 1 O - R 0x00 to 0xFF
M_SSEC_BASEPRM_RET2 T_UCHAR Return type 2 O - R 0x00 to 0xFF
M_SSEC_BASEPRM_ANIAXDIR T_UCHAR Animate ax direct O - RW 0 to 7
M_SSEC_BASEPRM_ANIAX1 T_STR Animate ax-1 O - RW Axis name
M_SSEC_BASEPRM_ANIAX2 T_STR Animate ax-2 O - RW Axis name
M_SSEC_BASEPRM_ANIAX3 T_STR Animate ax-3 O - RW Axis name
M_SSEC_BASEPRM_HACCC T_LONG Arc radius clamp acceleration (Hacc_c) O -- RW ±99999999
M_SSEC_BASEPRM_MACCC T_LONG Acceleration check at middle speed O -- RW ±99999999
(Macc_c)
M_SSEC_BASEPRM_LACCC T_LONG Acceleration check at low speed O -- RW ±99999999
(Lacc_c)
M_SSEC_BASEPRM_X_HCOFA T_LONG X axis high acceleration coefficient β O -- RW ±99999999
(Hcof_A)
M_SSEC_BASEPRM_X_HCOFB T_LONG X axis high acceleration coefficient α O -- RW ±99999999
(Hcof_B)
M_SSEC_BASEPRM_X_MCOFA T_LONG X axis middle acceleration coefficient β O -- RW ±99999999
(Mcof_A)
M_SSEC_BASEPRM_X_MCOFB T_LONG X axis middle acceleration coefficient α O -- RW ±99999999
(Mcof_B)
M_SSEC_BASEPRM_X_LCOFA T_LONG X axis low acceleration coefficient β O -- RW ±99999999
(Lcof_A)
M_SSEC_BASEPRM_X_LCOFB T_LONG X axis low acceleration coefficient α O -- RW ±99999999
(Lcof_B)
M_SSEC_BASEPRM_X_MAGC T_LONG X axis change magnification θ (mag_C) O -- RW ±99999999
M_SSEC_BASEPRM_Y_HCOFA T_LONG Y axis high acceleration coefficient β O -- RW ±99999999
(Hcof_A)
M_SSEC_BASEPRM_Y_HCOFB T_LONG Y axis high acceleration coefficient α O -- RW ±99999999
(Hcof_B)

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 194 of 206
inventcom

M_SSEC_BASEPRM_Y_MCOFA T_LONG Y axis middle acceleration coefficient β O -- RW ±99999999


(Mcof_A)
M_SSEC_BASEPRM_Y_MCOFB T_LONG Y axis middle acceleration coefficient α O -- RW ±99999999
(Mcof_B)
M_SSEC_BASEPRM_Y_LCOFA T_LONG Y axis low acceleration coefficient β O -- RW ±99999999
(Lcof_A)
M_SSEC_BASEPRM_Y_LCOFB T_LONG Y axis low acceleration coefficient α O -- RW ±99999999
(Lcof_B)
M_SSEC_BASEPRM_Y_MAGC T_LONG Y axis change magnification θ (mag_C) O -- RW ±99999999
M_SSEC_BASEPRM_STNAD T_CHAR station addr -- -- RW 1 to 7
M_SSEC_BASEPRM_INSIZ T_CHAR Din size -- -- RW 0 to 32
M_SSEC_BASEPRM_OTSIZ T_CHAR Dout size -- -- RW 0 to 32
M_SSEC_BASEPRM_DLENG T_CHAR data length -- -- RW 0 to 2: 7 bits , 3: 8 bits
M_SSEC_BASEPRM_BRATE T_CHAR baud rate -- -- RW 0 to 6
M_SSEC_BASEPRM_STPBT T_CHAR stop bit -- -- RW 0,1: 1 bit , 2,3: 2 bits
M_SSEC_BASEPRM_PRITY T_CHAR parity check -- -- RW 0,1
M_SSEC_BASEPRM_EVPTY T_CHAR even parity -- -- RW 0,1
M_SSEC_BASEPRM_TIMIN T_SHORT Tout (ini) -- -- RW 0 to 999
M_SSEC_BASEPRM_TIMRN T_SHORT Tout (run) -- -- RW 0 to 999
M_SSEC_BASEPRM_CLOCK T_CHAR clock select -- -- RW 0,1
M_SSEC_BASEPRM_WCOUNTM T_CHAR Workpiece count M O -- RW 0 to 99
M_SSEC_BASEPRM_WCOUNT T_LONG Workpiece count O -- RW 0 to 999999
M_SSEC_BASEPRM_WCOUNTMAX T_LONG Workpiece count limit O -- RW 0 to 999999
M_SSEC_BASEPRM_PG37F T_LONG Automatic tool length measurement O -- RW 1 to 100000
speed
M_SSEC_BASEPRM_PG37R T_FLOATBIN/T_LONG Automatic tool length measurement O -- RW 0 to 99999.999
deceleration zone r
M_SSEC_BASEPRM_PG37D T_FLOATBIN/T_LONG Automatic tool length measurement O -- RW 0 to 99999.999
deceleration zone d
M_SSEC_BASEPRM_OVRIDE T_CHAR Automatic corner override O -- RW 0 to 100
M_SSEC_BASEPRM_ANGLE T_LONG Automatic corner override maximum O -- RW 0 to 180
angle
M_SSEC_BASEPRM_INN T_FLOATBIN/T_LONG Automatic corner override deceleration O -- RW 0 to 99999.999
zone
M_SSEC_BASEPRM_MAMOU1 T_FLOATBIN/T_LONG Wear data input maximum absolute O -- RW 0 to 99.999
value

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 195 of 206
inventcom

M_SSEC_BASEPRM_MAMOU2 T_FLOATBIN/T_LONG Wear data input maximum increment O -- RW 0 to 99.999


value
M_SSEC_BASEPRM_G73 T_FLOATBIN/T_LONG G73 return O -- RW 0 to 99999.999
M_SSEC_BASEPRM_G83 T_FLOATBIN/T_LONG G83 return O -- RW 0 to 99999.999
M_SSEC_BASEPRM_CHANF T_CHAR Chamfering amount O -- RW 0 to 127
M_SSEC_BASEPRM_G78 T_CHAR Angle O -- RW 0 to 89
M_SSEC_BASEPRM_AMARI T_FLOATBIN/T_LONG G71 minimum cut amount O -- RW 0 to 99.999
M_SSEC_BASEPRM_LAPDLT T_FLOATBIN/T_LONG Delta D O -- RW 0 to 99.999
M_SSEC_BASEPRM_PEKRVM T_FLOATBIN/T_LONG G84/G74 return O -- RW 0 to 999.999
M_SSEC_BASEPRM_RCOMP T_CHAR Accuracy factor O -- RW 0 to 99
M_SSEC_BASEPRM_FCORN T_CHAR Corner deceleration angle O -- RW 0 to 89
M_SSEC_BASEPRM_RCOMP_CHG T_LONG Accuracy factor change O -- RW 0,1
M_SSEC_BASEPRM_RCOMP1 T_LONG Corner accuracy factor O -- RW -1000 to 99
M_SSEC_BASEPRM_RCOMP2 T_LONG Curve accuracy factor O -- RW -1000 to 99
M_SSEC_BASEPRM_SPLINE T_CHAR High-accuracy spline enabled O -- RW 0/1
M_SSEC_BASEPRM_SPCAN_ANGL T_SHORT Cancel angle O -- RW 0 to 180
M_SSEC_BASEPRM_DISTTH1 T_FLOATBIN/T_LONG Chord error 1 O -- RW 0 to 100.000
M_SSEC_BASEPRM_DISTTH2 T_FLOATBIN/T_LONG Chord error 2 O -- RW 0 to 100.000
M_SSEC_BASEPRM_MINLENG T_FLOATBIN/T_LONG Fairing length O -- RW 0 to 100.000
M_SSEC_BASEPRM_MINUTE T_CHAR Minute length O -- RW -1 to 127
M_SSEC_BASEPRM_FAIRING_ON T_LONG Fairing enabled O -- RW 0,1
M_SSEC_BASEPRM_ACCCLAMP_ON T_LONG Acceleration clamp enabled O -- RW 0,1
M_SSEC_BASEPRM_ACCCLAMP_MAG T_LONG Acceleration clamp magnification O -- RW 0 to 999
M_SSEC_BASEPRM_CORDEC_JUDGE T_LONG Corner judge change O -- RW 0,1
M_SSEC_BASEPRM_CORDEC_JUDGE_L T_FLOATBIN/T_LONG Corner judge length O -- RW 0 to 99999.999
M_SSEC_BASEPRM_C_ROTR T_FLOATBIN/T_LONG C axis rotation radius O -- RW 0 to 99999.999
M_SSEC_BASEPRM_C_CONR T_FLOATBIN/T_LONG C axis insertion radius O -- RW 0 to 99999.999
M_SSEC_BASEPRM_HDL_OFS T_FLOATBIN/T_LONG Handle compensation amount O -- RW 0 to 99999.999
M_SSEC_BASEPRM_PRUNIT10PRM T_LONG Unit 10-fold -- -- RW 0 to 10000
M_SSEC_BASEPRM_LAPCUT T_FLOATBIN/T_LONG G71 cut-in O -- RW 0 to 99999.999
M_SSEC_BASEPRM_G71 T_FLOATBIN/T_LONG G71 pull up O -- RW 0 to 99999.999
M_SSEC_BASEPRM_LAPX T_FLOATBIN/T_LONG G73 cutting X O -- RW ±99999.999
M_SSEC_BASEPRM_LAPZ T_FLOATBIN/T_LONG G73 cutting Z O -- RW ±99999.999
M_SSEC_BASEPRM_LAPCT T_LONG G73 number of times O -- RW 0 to 99999
M_SSEC_BASEPRM_G74 T_FLOATBIN/T_LONG G74 retract O -- RW 0 to 99.999
M_SSEC_BASEPRM_G76 T_FLOATBIN/T_LONG G76 final cut-in O -- RW 0 to 99.999

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 196 of 206
inventcom

M_SSEC_BASEPRM_G76CT T_CHAR G76 number of times O -- RW 0 to 99


M_SSEC_BASEPRM_G76AN T_CHAR G76 thread angle O -- RW 0 to 99
M_SSEC_BASEPRM_P3D T_FLOATBIN/T_LONG 3-dimensional compensation O -- RW 0 to 99999.999
M_SSEC_BASEPRM_SCALE T_FLOATBIN/T_LONG Scaling magnification O -- RW 0 to 99.999999
M_SSEC_BASEPRM_SPIRAL_ERR T_FLOATBIN/T_LONG End point error in spiral Q and K O -- RW 0 to 99999.999
incremental command (Type 2)
M_SSEC_BASEPRM_SCRN_TIME T_CHAR Screen saver time -- -- RW 0 to 60
M_SSEC_BASEPRM_G83SMCOD T_LONG G83 small diameter mode M code O -- RW 1 to 99999999
M_SSEC_BASEPRM_G83SCLRN T_FLOATBIN/T_LONG G83 small diameter clearance amount O -- RW 0 to 999.999
M_SSEC_BASEPRM_G83SFWD_F T_LONG G83 small diameter cutting start O -- RW 0 to 99999
position feedrate
M_SSEC_BASEPRM_G83SBAK_F T_LONG G83 small diameter retract speed O -- RW 0 to 99999
M_SSEC_BASEPRM_SSS_ON T_LONG SSS control enabled O -- RW 0,1
M_SSEC_BASEPRM_STDLENGTH T_FLOATBIN/T_LONG Standard length O -- RW 0.000 to 100.000
M_SSEC_BASEPRM_CLAMP_COEFF T_SHORT Clamp speed coefficient O -- RW 1 to 100
M_SSEC_BASEPRM_STEP_LENGTH T_FLOATBIN/T_LONG Step length O -- RW --0.001 to 0.100
M_SSEC_BASEPRM_DCC_WAIT_ADD T_CHAR Deceleration wait time O -- RW 0 to 100
M_SSEC_BASEPRM_MACSINGLE T_LONG Macro single -- -- RW 0,1
M_SSEC_BASEPRM_COLLALMOFF T_LONG Collision avoidance -- -- RW 0,1
M_SSEC_BASEPRM_COLLCHKOFF T_LONG Collision invalid -- -- RW 0,1
M_SSEC_BASEPRM_EDTLCKB T_LONG Edit lock B -- -- RW 0,1
M_SSEC_BASEPRM_G46ERR T_LONG G46 reverse axis error avoidance -- -- RW 0,1
M_SSEC_BASEPRM_MCERRRAD T_LONG Radius error compensation -- -- RW 0,1
M_SSEC_BASEPRM_CNGMCERRRAD T_LONG Radius error compensation change -- -- RW 0,1
M_SSEC_BASEPRM_HOSTLNK T_CHAR Host communication -- -- RW 0,1
M_SSEC_BASEPRM_POCKET_ON T_CHAR G71/G72 pocket machining ON -- -- RW 0,1
M_SSEC_BASEPRM_MILL_R T_LONG Milling radius value designation -- -- RW 0,1
M_SSEC_BASEPRM_G04P T_LONG G04P decimal point valid -- -- RW 0,1
M_SSEC_BASEPRM_MILL_INIG16 T_LONG Milling initial G16 -- -- RW 0,1
M_SSEC_BASEPRM_MILL_INIG19 T_LONG Milling initial G19 -- -- RW 0,1
M_SSEC_BASEPRM_COORDOFF T_LONG Coordinate rotation parameter disabled -- -- RW 0,1
M_SSEC_BASEPRM_OFSDIAM T_LONG Diameter designation in radius -- -- RW 0,1
compensation enabled
M_SSEC_BASEPRM_COMPUNITSWITCH T_LONG Compensation amount setting unit -- -- RW 0,1
switch
M_SSEC_BASEPRM_SCRNCAP T_LONG Screen capture -- -- RW 0,1

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 197 of 206
inventcom

M_SSEC_BASEPRM_KEEP_G43 T_LONG Keep manual R return G43 (Only M -- -- RW 0,1


system)
M_SSEC_BASEPRM_DRIL_QR T_LONG High-speed retract enabled -- -- RW 0,1
M_SSEC_BASEPRM_RST_MR T_LONG Mirror operation at reset -- -- RW 0,1
M_SSEC_BASEPRM_UPRM_F1 T_LONG #8145 F1-digit feet enabled -- -- RW 0,1
M_SSEC_BASEPRM_EXTDCC_AX T_LONG External deceleration axis support -- -- RW 0,1
enabled
M_SSEC_BASEPRM_SUBPRO_INTER T_LONG Sub-pro interrupt -- -- RW 0,1
M_SSEC_BASEPRM_FINE_THRECUT_E T_LONG Fine thread cut E -- -- RW 0,1
M_SSEC_BASEPRM_COMP_TYPE_B T_LONG Radius comp type B (M system) / Nose -- -- RW 0,1
R comp type B (L system)
M_SSEC_BASEPRM_INITCONST_SUR_SPD T_LONG Initial constant surface speed -- -- RW 0,1
M_SSEC_BASEPRM_SYNTAP T_LONG Synchronous tapping -- -- RW 0,1
M_SSEC_BASEPRM_STARTP_ALARM T_LONG Start point alarm -- -- RW 0,1
M_SSEC_BASEPRM_HOLD_INTR_AMOUNT T_LONG Keep interruption amount O -- RW 0,1
M_SSEC_BASEPRM_LKYOKO T_STR Coordinate rotation plane (Horizontal O - RW Axis name
axis name)
M_SSEC_BASEPRM_LKTATE T_STR Coordinate rotation plane (Vertical axis O - RW Axis name
name)
M_SSEC_BASEPRM_LKCENTY T_FLOATBIN/T_LONG Coordinate rotation center coordinate O - RW ±99999.999
(Horizontal axis)
M_SSEC_BASEPRM_LKSENTT T_FLOATBIN/T_LONG Coordinate rotation center coordinate O - RW ±99999.999
(Vertical axis)
M_SSEC_UPBARI_BARI3Z T_FLOATBIN/T_LONG P3 Z -- -- RW ±99999.999
M_SSEC_UPBARI_BARI4X T_FLOATBIN/T_LONG P4 X -- -- RW ±99999.999
M_SSEC_UPBARI_BARI4Z T_FLOATBIN/T_LONG P4 Z -- -- RW ±99999.999
M_SSEC_UPBARI_BARI5X T_FLOATBIN/T_LONG P5 X -- -- RW ±99999.999
M_SSEC_UPBARI_BARI5Z T_FLOATBIN/T_LONG P5 Z -- -- RW ±99999.999
M_SSEC_UPBARI_BARI6X T_FLOATBIN/T_LONG P6 X -- -- RW ±99999.999
M_SSEC_UPBARI_BARI6Z T_FLOATBIN/T_LONG P6 Z -- -- RW ±99999.999
M_SSEC_UPBARI_BARI_ON T_CHAR Barrier ON O -- RW 0,1
M_SSEC_UPBARI_BARI7X T_FLOATBIN/T_LONG P7 X O -- RW ±99999.999
M_SSEC_UPBARI_BARI8X T_FLOATBIN/T_LONG P8 X O -- RW ±99999.999
M_SSEC_UPBARI_BARI8Z T_FLOATBIN/T_LONG P8 Z O -- RW ±99999.999
M_SSEC_UPBARI_BARI9X T_FLOATBIN/T_LONG P9 X O -- RW ±99999.999
M_SSEC_UPBARI_BARI10X T_FLOATBIN/T_LONG P10 X O -- RW ±99999.999

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 198 of 206
inventcom

M_SSEC_UPBARI_BARI10Z T_FLOATBIN/T_LONG P10 Z O -- RW ±99999.999


M_SSEC_UPBARI_BRFORML T_CHAR Barrier type (Left) O -- RW 0 to 2
M_SSEC_UPBARI_BRFORMR T_CHAR Barrier type (Right) O -- RW 0 to 2
M_SSEC_UPBARI_BARI_SC T_STR Delivery axis name O -- RW Axis name
M_SSEC_UPBARI_TAIL_AL T_SHORT Tail stock angle (Left) O -- RW 0 to 180
M_SSEC_UPBARI_TAIL_AR T_SHORT Tail stock angle (Right) O -- RW 0 to 180
M_SSEC_MPLMAC_TSMACRO T_STR Smac program No. -- -- RW 0 to 999999999
M_SSEC_MPLMAC_TTMACROT T_CHAR Tmac type -- -- RW 0 to 3
M_SSEC_MPLMAC_TTMACRO T_STR Tmac program No. -- -- RW 0 to 999999999
M_SSEC_MPLMAC_ASC_MACSET(x) T_LONG ASCII[]ASCII code macro valid (x=1 to O -- RW 0,1
2)
M_SSEC_MPLMAC_ASC_CODE(x) T_STR ASCII[]ASCII code (x=1 to 2) O -- RW A to Z
M_SSEC_MPLMAC_ASC_TYPE(x) T_CHAR ASCII[]calling type O -- RW 0 to 3
(0:M98,1:G65,2:G66,3:G66.1) (x=1 to 2)
M_SSEC_MPLMAC_ASC_PROGNO(x) T_STR ASCII[]program No. (x=1 to 2) O -- RW 0 to 99999999
M_SSEC_MPLMAC_ASC_COM_VAL(x) T_SHORT ASCII[]common variable No. (100 to O -- RW 0,100 to 149
149) (x=1 to 2)

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 199 of 206
inventcom

Synchronization error monitor


Command Data type Description PS AX RW Range
M_SSEC_MSERR_DOK1_SGOSA T_FLOATBIN/T_LONG Command error (1st set) -- -- R
M_SSEC_MSERR_DOK2_SGOSA T_FLOATBIN/T_LONG Command error (2nd set) -- -- R
M_SSEC_MSERR_DOK3_SGOSA T_FLOATBIN/T_LONG Command error (3rd set) -- -- R
M_SSEC_MSERR_DOK1_FBGOSA T_FLOATBIN/T_LONG FB error (1st set) -- -- R
M_SSEC_MSERR_DOK2_FBGOSA T_FLOATBIN/T_LONG FB error (2nd set) -- -- R
M_SSEC_MSERR_DOK3_FBGOSA T_FLOATBIN/T_LONG FB error (3rd set) -- -- R
M_SSEC_MSERR_DOK1_MACHIN T_FLOATBIN/T_LONG Machine position (1st set) -- -- R
M_SSEC_MSERR_DOK2_MACHIN T_FLOATBIN/T_LONG Machine position (2nd set) -- -- R
M_SSEC_MSERR_DOK3_MACHIN T_FLOATBIN/T_LONG Machine position (3rd set) -- -- R
M_SSEC_MSERR_DOK1_SLVNO T_CHAR Slave axis No. (1st set) -- -- R
M_SSEC_MSERR_DOK2_SLVNO T_CHAR Slave axis No. (2nd set) -- -- R
M_SSEC_MSERR_DOK3_SLVNO T_CHAR Slave axis No. (3rd set) -- -- R
M_SSEC_MSERR_DOK1_FBMAX1 T_FLOATBIN/T_LONG FB error MAX1 (1st set) -- -- R
M_SSEC_MSERR_DOK2_FBMAX1 T_FLOATBIN/T_LONG FB error MAX1 (2nd set) -- -- R
M_SSEC_MSERR_DOK3_FBMAX1 T_FLOATBIN/T_LONG FB error MAX1 (3rd set) -- -- R
M_SSEC_MSERR_DOK1_FBMAX2 T_FLOATBIN/T_LONG FB error MAX2 (1st set) -- -- R
M_SSEC_MSERR_DOK2_FBMAX2 T_FLOATBIN/T_LONG FB error MAX2 (2nd set) -- -- R
M_SSEC_MSERR_DOK3_FBMAX2 T_FLOATBIN/T_LONG FB error MAX2 (3rd set) -- -- R

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 200 of 206
inventcom

Tool compensation by each part system (Type 1)


Command Data type Description PS AX RW Range
M_SSEC_TOFS1S_MC_DAT(x) T_FLOATBIN/T_LONG Compensation data (x=1 to 999) O -- RW ±99999.999

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 201 of 206
inventcom

Tool compensation by each part system (Type 2)


Command Data type Description PS AX RW Range
M_SSEC_TOFS2S_LENG(x) T_FLOATBIN/T_LONG Length (x=1 to 999) O -- RW ±99999.999
M_SSEC_TOFS2S_RADIUS(x) T_FLOATBIN/T_LONG Diameter (x=1 to 999) O -- RW ±999.999

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 202 of 206
inventcom

Tool compensation by each part system (Type 3)


Command Data type Description PS AX RW Range
M_SSEC_TOFS3S_EDGE_P(x) T_CHAR Tool tip P (x=1 to 999) O -- RW 0 to 9
M_SSEC_TOFS3S_LENG_X(x) T_FLOATBIN/T_LONG Tool length X (x=1 to 999) O -- RW ±999.999
M_SSEC_TOFS3S_LENG_Y(x) T_FLOATBIN/T_LONG Tool length Y (x=1 to 999) O -- RW ±999.999
M_SSEC_TOFS3S_LENG_Z(x) T_FLOATBIN/T_LONG Tool length Z (x=1 to 999) O -- RW ±999.999
M_SSEC_TOFS3S_EDGE_R(x) T_FLOATBIN/T_LONG Tool tip R (x=1 to 999) O -- RW 0 to 999.999
M_SSEC_TOFS3S_WEAR_X(x) T_FLOATBIN/T_LONG Wear X (x=1 to 999) O -- RW ±99.999
M_SSEC_TOFS3S_WEAR_Y(x) T_FLOATBIN/T_LONG Wear Y (x=1 to 999) O -- RW ±99.999
M_SSEC_TOFS3S_WEAR_Z(x) T_FLOATBIN/T_LONG Wear Z (x=1 to 999) O -- RW ±99.999
M_SSEC_TOFS3S_WEAR_R(x) T_FLOATBIN/T_LONG Wear R (x=1 to 999) O -- RW 0 to 99.999

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 203 of 206
inventcom

Tool management data


Command Data type Description PS AX RW Range
M_SSEC_TOLMNG_TNO(x) T_LONG Tool No. (x=1 to 1000) -- -- RW 8 digit T: 0 to 99999999, 4 digit T:
0 to 9999
M_SSEC_TOLMNG_KIND(x) T_CHAR Tool type (x=1 to 1000) -- -- RW 0 to 7
M_SSEC_TOLMNG_RADIUS(x) T_FLOATBIN Tool diameter (x=1 to 1000) -- -- RW 0 to 999999.999
M_SSEC_TOLMNG_LENGTH(x) T_FLOATBIN Tool length (x=1 to 1000) -- -- RW 0 to 999999.999
M_SSEC_TOLMNG_DATA1(x) T_FLOATBIN Tool shape data 1 (x=1 to 1000) -- -- RW 0 to 999999.999
M_SSEC_TOLMNG_DATA2(x) T_FLOATBIN Tool shape data 2 (x=1 to 1000) -- -- RW 0 to 999999.999
M_SSEC_TOLMNG_COLOR(x) T_CHAR Tool colour (x=1 to 1000) -- -- RW 0 to 8
M_SSEC_TOLMNG_HOL_H(x) T_FLOATBIN Holder height (x=1 to 1000) -- -- RW 0 to 999999.999
M_SSEC_TOLMNG_HOL_R(x) T_FLOATBIN Holder diameter (x=1 to 1000) -- -- RW 0 to 999999.999
M_SSEC_TOLMNG_TREGDAT_ALL(x) T_BUFF Tool registration data (All) (x=1 to 1000) -- -- R Magazine No./Pot No/Aux D
M_SSEC_TOLMNG_FORMAT T_CHAR Tool management data format -- -- W 1
M_SSEC_TOLMNG_TNO_CHK T_LONG Tool management tool No. duplication -- -- W 0 to 99999999 or, 0 to 9999
check

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 204 of 206
inventcom

Tool measurement
Command Data type Description PS AX RW Range
M_SSEC_TLM_SW T_LONG TLM switch O -- R
M_SSEC_TLM_LAST_MOVE_DIRECTION T_CHAR Last travel direction O O R 0: Positive, 1: Negative
M_SSEC_TLM_LAST_MOVE_AXIS T_CHAR Last travel axis O -- R 0: No travel, 1 to 8: Axis number
which moved
M_SSEC_TLM_SECOND_SKIP T_SHORT 2nd skip contact O -- R 0: EMG status, 1: Stoppd state
M_SSEC_TLM_RST_INPUT_STS T_CHAR Reset input status O -- RW 0: Reset is not input (OFF) 1:
Reset is input (OFF-->ON)
M_SSEC_TLM_SKP_POS_READ_STS T_CHAR Skip position read status O -- RW 0: Skip position is not read yet 1:
Skip position is read
M_SSEC_TLM_TLMS_SW T_LONG TLMS status (L sys tool measure 2) O -- R 0,1
M_SSEC_TLM_L2_STS T_LONG Tool compensation amount measure O -- RW Setting is only 0
status (L sys tool measure 2)
M_SSEC_TLM_EXTWOFS_STS T_LONG External workpiece coordinate offset O -- RW Setting is only 0
measure status (L sys tool measure 2)
M_SSEC_TLM_L2_START T_LONG Tool compensation amount measure O -- RW 0, 1
request (L sys tool measure 2)
M_SSEC_TLM_EXTWOFS_START T_LONG External workpiece coordinate offset O -- RW 0, 1
measure request (L sys tool measure 2)

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 205 of 206
inventcom

Tool registration
Command Data type Description PS AX RW Range
M_SSEC_TOLREG_POT_NO(x) T_LONG Tool registration data (Pot No.) (x=1 to O -- R
360)
M_SSEC_TOLREG_TOOL_NO(x) T_LONG Tool registration data (Tool No.) (x=1 to O -- RW 0 to 99999999/0 to 9999
360)
M_SSEC_TOLREG_D_NO(x) T_SHORT Tool registration data (Auxiliary: D) (x=1 O -- RW 0 to 99
to 360)

MITSUBISHI M700/7ß API VARIABLE LIST


Inventcom · www.inventcom.net · info@inventcom.net
Version: August 2017 V1.3
Page 206 of 206

You might also like