Professional Documents
Culture Documents
Mitsubishi M700 70 Variable List
Mitsubishi M700 70 Variable List
Anshin-net 1
Command Data type Description PS AX RW Range
M_SSEC_MPANET1_CALLBACK_NUM1 T_STR Telephone number to contact 1 -- -- RW Within 28 letters
M_SSEC_MPANET1_CALLBACK_COM1 T_STR Comment1 -- -- RW Within 20 letters
M_SSEC_MPANET1_CALLBACK_NUM2 T_STR Telephone number to contact 2 -- -- RW Within 28 letters
M_SSEC_MPANET1_CALLBACK_COM2 T_STR Comment2 -- -- RW Within 20 letters
M_SSEC_MPANET1_CALLBACK_NUM3 T_STR Telephone number to contact 3 -- -- RW Within 28 letters
M_SSEC_MPANET1_CALLBACK_COM3 T_STR Comment3 -- -- RW Within 20 letters
M_SSEC_MPANET1_ENABLE_ANET T_CHAR Anshin-net enabled -- -- RW 0,1
M_SSEC_MPANET1_ENABLE_KNET T_LONG MTB-net enabled - -- RW 0,1
M_SSEC_MPANET1_PASSWD T_STR Password in machining data share - - RW 4 letters (Alphanumeric
characters, excluding space)
M_SSEC_MPANET1_CUSTOMER_NUM T_STR Customer No. in machining data share - - RW 8 letters (Alphanumeric
characters, excluding space)
Anshin-net 2
Command Data type Description PS AX RW Range
M_SSEC_MPANET2_MODEM_NUM T_STR Modem's telephone number -- -- RW Within 28 letters
M_SSEC_MPANET2_CALL_NUM T_STR Call centre’s telephone No. -- -- RW Within 28 letters
M_SSEC_MPANET2_KOUKI_NUM T_STR MTB’s telephone No. -- -- RW Within 28 letters
M_SSEC_MPANET2_ARV_CALL_NUM1 T_STR Num arrival call 1 -- -- RW Within 28 letters
M_SSEC_MPANET2_ARV_CALL_NUM2 T_STR Num arrival call 2 -- -- RW Within 28 letters
M_SSEC_MPANET2_ARV_CALL_NUM3 T_STR Num arrival call 3 -- -- RW Within 28 letters
M_SSEC_MPANET2_ARV_CALL_NUM4 T_STR Num arrival call 4 -- -- RW Within 28 letters
M_SSEC_MPANET2_ARV_CALL_NUM5 T_STR Num arrival call 5 -- -- RW Within 28 letters
M_SSEC_MPANET2_ARV_KOUKI_NUM(x) T_STR MTB's num arrival call (x=1 to 5) -- -- RW Within 28 letters
M_SSEC_MPANET2_RETRY T_SHORT Number of times to retry -- -- RW 0 to 255
M_SSEC_MPANET2_ENABLE_ANET T_CHAR Automatic selection of Anshin net -- -- RW 0,1
screen
M_SSEC_MPANET2_COND_KIND1 T_STR Condition 1 (Kind/Register) -- -- RW Within 5 letters
M_SSEC_MPANET2_COND_NUM1 T_STR Condition 1 (No./Status value) -- -- RW Within 4 letters
M_SSEC_MPANET2_COND_KIND2 T_STR Condition 2 (Kind/Register) -- -- RW Within 5 letters
M_SSEC_MPANET2_COND_NUM2 T_STR Condition 2 (No./Status value) -- -- RW Within 4 letters
M_SSEC_MPANET2_COND_KIND3 T_STR Condition 3 (Kind/Register) -- -- RW Within 5 letters
M_SSEC_MPANET2_COND_NUM3 T_STR Condition 3 (No./Status value) -- -- RW Within 4 letters
M_SSEC_MPANET2_COND_KIND4 T_STR Condition 4 (Kind/Register) -- -- RW Within 5 letters
M_SSEC_MPANET2_COND_NUM4 T_STR Condition 4 (No./Status value) -- -- RW Within 4 letters
M_SSEC_MPANET2_COND_KIND5 T_STR Condition 5 (Kind/Register) -- -- RW Within 5 letters
M_SSEC_MPANET2_COND_NUM5 T_STR Condition 5 (No./Status value) -- -- RW Within 4 letters
M_SSEC_MPANET2_COND_KIND6 T_STR Condition 6 (Kind/Register) -- -- RW Within 5 letters
M_SSEC_MPANET2_COND_NUM6 T_STR Condition 6 (No./Status value) -- -- RW Within 4 letters
M_SSEC_MPANET2_COND_KIND7 T_STR Condition 7 (Kind/Register) -- -- RW Within 5 letters
M_SSEC_MPANET2_COND_NUM7 T_STR Condition 7 (No./Status value) -- -- RW Within 4 letters
M_SSEC_MPANET2_COND_KIND8 T_STR Condition 8 (Kind/Register) -- -- RW Within 5 letters
M_SSEC_MPANET2_COND_NUM8 T_STR Condition 8 (No./Status value) -- -- RW Within 4 letters
M_SSEC_MPANET2_COND_KIND9 T_STR Condition 9 (Kind/Register) -- -- RW Within 5 letters
M_SSEC_MPANET2_COND_NUM9 T_STR Condition 9 (No./Status value) -- -- RW Within 4 letters
M_SSEC_MPANET2_COND_KIND10 T_STR Condition 10 (Kind/Register) -- -- RW Within 5 letters
M_SSEC_MPANET2_COND_NUM10 T_STR Condition 10 (No./Status value) -- -- RW Within 4 letters
Anshin-net I/F
Command Data type Description PS AX RW Range
M_SSEC_ANETIF_CALL T_CHAR One-touch call -- -- RW 0,1
M_SSEC_ANETIF_NOTICEOP T_CHAR Operator notice -- -- RW 0,1
M_SSEC_ANETIF_OPTIONALNO T_STR Arbitrary No. -- -- RW 28 letters (Numerical, "#", "*", "-")
M_SSEC_ANETIF_CALLSEL T_CHAR Notice telephone No. -- -- RW 1 to 4
M_SSEC_ANETIF_ANETMSGSTS T_CHAR Anshin-net message status -- -- R 0 to 8
M_SSEC_ANETIF_HOSTMSG T_STR Message from NC service -- -- R 74*5 letters
M_SSEC_ANETIF_COMMSTS T_CHAR Anshin-net communication situation -- -- R 0 to 11,99
M_SSEC_ANETIF_NET_STS T_CHAR Anshin-net communication status -- -- RW 0 to 10/Set 0
M_SSEC_ANETIF_NET_COMMAND T_SHORT Anshin-net/MTB-net communication -- -- R 0 to 7
command
M_SSEC_ANETIF_NS_COMMODE T_CHAR Anshin-net communication mode -- -- R 0 to
M_SSEC_ANETIF_ERRNO T_SHORT Anshin-net/MTB-net error code -- -- R 0: No error, 1 - : Error code
M_SSEC_ANETIF_CHGSTS T_CHAR Screen change status -- -- RW Get: 0,1/Set: 0
M_SSEC_ANETIF_CHGREST T_CHAR Screen change restriction information -- -- R 1,2
M_SSEC_ANETIF_DIAG_INFO_SEND T_LONG MTB-net diagnosis information - -- W 1
transmission
M_SSEC_ANETIF_WARN_CANCEL T_LONG MTB-net warning cancel - -- W 1
M_SSEC_ANETIF_MESS_RECV T_STR MTB-net message reception - -- R 355 letters (71 lines * 5 digits)
M_SSEC_ANETIF_KNET_COMMSTS T_CHAR MTB-net communication situation - -- R 0 to 12,99
M_SSEC_ANETIF_KNET_STS T_CHAR MTB-net communication status - -- RW 0 to 10/Setting 0
M_SSEC_ANETIF_KNET_NS_COMMODE T_CHAR MTB-net communication mode - -- R 0 to 8
M_SSEC_ANETIF_DEV_NAME T_STR Device name for transmission in - - W Within 8 letters
machining data share
M_SSEC_ANETIF_DIR_NAME T_STR Directory name for transmission in - - W Within 80 letters
machining data share
M_SSEC_ANETIF_FILE_NAME T_STR File name for transmission in machining - - W Within 32 letters
data share
M_SSEC_ANETIF_FILE_SIZE T_LONG File size for transmission in machining - - W 0 to 2147483647
data share
M_SSEC_ANETIF_DEV_FREE_SIZE T_LONG Remaining capacity of device for - - W 0 to 2147483647
transmission in machining data share
M_SSEC_ANETIF_ANET_FILE_NAME_PUT T_STR File name of Anshin-net server for - - W Only numericals, within 10 letters
sending in machining data share
M_SSEC_ANETIF_ANET_FILE_NAME_GET T_STR File name of Anshin-net server for - - W Only numericals, within 11 letters
reception in machining data share
M_SSEC_ANETIF_ANET_FILE_NAME_DEL T_STR File name of Anshin-net server for - - W Only numericals, within 12 letters
deletion in machining data share
M_SSEC_ANETIF_REQ_STS T_UCHAR Get execution request status by each - - R 0 to 0xFF
function fo Anshin-net and MTB-net
Axis parameter
Command Data type Description PS AX RW Range
M_SSEC_AXISPRM_NAME T_STR Axis name O O RW 1 letter
M_SSEC_AXISPRM_DSP_NAME T_STR Display axis name O O RW 2 letters
M_SSEC_AXISPRM_INCNAME T_STR Increment command axis name O O RW 1 letter
M_SSEC_AXISPRM_CS T_LONG Command unit O O RW 0,1,2,10,20,50,100,1000,10000,
etc.
M_SSEC_AXISPRM_IOUT T_LONG Inch output O O RW 0,1
M_SSEC_AXISPRM_ROT T_LONG Rotary axis O O RW 0,1
M_SSEC_AXISPRM_CCW T_LONG Motor ccw O O RW 0,1
M_SSEC_AXISPRM_DIA T_LONG Diameter specification axis O O RW 0,1
M_SSEC_AXISPRM_SPAX T_LONG Spindle interpolation O O RW 0,1
M_SSEC_AXISPRM_MCP_NO T_SHORT Drive unit interface channel No. O O RW 0x0, 0x101 to 0x107, 0x201 to
0x207
M_SSEC_AXISPRM_CRS_ADR T_STR Command address during cross O O RW 0, A to Z
machining
M_SSEC_AXISPRM_CRS_INC T_STR Incremental command address during O O RW 0, A to Z, other than the address
cross machining already used in the part system
M_SSEC_AXISPRM_INTABS T_LONG Manual ABS updating O O RW 0,1
M_SSEC_AXISPRM_TCOMP T_CHAR Tool compensation function O O RW 0 to 3
M_SSEC_AXISPRM_MANDOG T_LONG Manual dog-type O O RW 0,1
M_SSEC_AXISPRM_SVOF T_LONG Error correction O O RW 0,1
M_SSEC_AXISPRM_JOGH T_CHAR JOG response type O O RW 0 to 4
M_SSEC_AXISPRM_JOGHP T_SHORT Select JOG activation (+) device O O RW Device No. (0 to 5119)
M_SSEC_AXISPRM_JOGHN T_SHORT Select JOG activation (-) device O O RW Device No. (0 to 5119)
M_SSEC_AXISPRM_TSLVNO T_CHAR Slave axis number O O RW 0 to 4
M_SSEC_AXISPRM_NO_DSP T_LONG No_dsp O O RW 0,1
M_SSEC_AXISPRM_AXOFF T_LONG Axis removal O O RW 0,1
M_SSEC_AXISPRM_JOGD T_CHAR ±JOG activation signal device name O O RW 0 to 2
M_SSEC_AXISPRM_CHOP_AX T_LONG Chopping axis O O RW 0,1
M_SSEC_AXISPRM_OUTUNIT T_STR Output unit (Servo) O O RW B,C,D,E
M_SSEC_AXISPRM_REF_SYN T_LONG Synchronization at zero point O O RW 0 to 1
initialization
M_SSEC_AXISPRM_DSP_AX_CHG T_CHAR Axis order of counter display O O RW 0 to 8
M_SSEC_AXISPRM_RAPID T_LONG Rapid O O RW 1 to 1000000
Axis status
Command Data type Description PS AX RW Range
M_SSEC_AXISSTS_POFF T_CHAR Axis status (Axis removal) O O R
M_SSEC_AXISSTS_SVOF T_CHAR Axis status (Servo OFF) O O R
M_SSEC_AXISSTS_REF1 T_CHAR Axis status (1st ref) O O R
M_SSEC_AXISSTS_REF2 T_CHAR Axis status (2nd ref) O O R
M_SSEC_AXISSTS_REF3 T_CHAR Axis status (3rd ref) O O R
M_SSEC_AXISSTS_REF4 T_CHAR Axis status (4th ref) O O R
M_SSEC_AXISSTS_MR T_CHAR Axis status (Mirror image) O O R
M_SSEC_AXISSTS_RSTAT T_CHAR Axis status (Restart search RP) O O R
M_SSEC_AXISSTS_CT T_CHAR Axis status (Auxiliary axis status CT) O O R 0 to 1 (T_STR : "CT")
M_SSEC_AXISSTS_SVOF_AL T_SHORT Axis status (Servo OFF) all axes O -- R
M_SSEC_AXISSTS_REF1_AL T_SHORT Axis status (1st ref) all axes O -- R
M_SSEC_AXISSTS_REF2_AL T_SHORT Axis status (2nd ref) all axes O -- R
M_SSEC_AXISSTS_REF3_AL T_SHORT Axis status (3rd ref) all axes O -- R
M_SSEC_AXISSTS_REF4_AL T_SHORT Axis status (4the ref) all axes O -- R
M_SSEC_AXISSTS_MR_AL T_LONG Axis status (Mirror image) all axes O -- R
M_SSEC_AXISSTS_RP_AL T_SHORT Axis status (Restart search RP) all axes O -- R
M_SSEC_AXISSTS_PROG_MR_AL T_SHORT Programmed mirror axis (all axes) O -- R
M_SSEC_AXISSTS_AXOFST T_CHAR Information in control axis removal O O R
M_SSEC_AXISSTS_FDT_DIRECT T_CHAR Axis travel direction (FDT direction) O O R 0: No travel 1: Travelling to -
direction 2: Travelling to +
direction
Background check
Command Data type Description PS AX RW Range
M_SSEC_PRGCHK_OPT_BLKSKIP T_CHAR Optional block skip O -- RW 0,1
Barrier
Command Data type Description PS AX RW Range
M_SSEC_UPBARI_BARI0X T_FLOATBIN/T_LONG P0 X -- -- RW ±99999.999
M_SSEC_UPBARI_BARI1X T_FLOATBIN/T_LONG P1 X -- -- RW ±99999.999
M_SSEC_UPBARI_BARI1Z T_FLOATBIN/T_LONG P1 Z -- -- RW ±99999.999
M_SSEC_UPBARI_BARI2X T_FLOATBIN/T_LONG P2 X -- -- RW ±99999.999
M_SSEC_UPBARI_BARI2Z T_FLOATBIN/T_LONG P2 Z -- -- RW ±99999.999
M_SSEC_UPBARI_BARI3X T_FLOATBIN/T_LONG P3 X -- -- RW ±99999.999
Base parameter
Command Data type Description PS AX RW Range
M_SSEC_BASEPRM_SYSON T_CHAR System validation setup O -- RW 0,1
M_SSEC_BASEPRM_PLCSYSON T_CHAR System validation setup (PLC) -- -- RW 0,1
M_SSEC_BASEPRM_AXISMAS T_CHAR Number of axes O -- RW 0 to SYSTEM_AXIS_NO(8)
M_SSEC_BASEPRM_PLCAXISMAS T_CHAR Number of axes (PLC) -- -- RW 0 to PLCMAX(2)
M_SSEC_BASEPRM_IUNIT T_STR Input setup unit O -- RW A,B,C,D,E
M_SSEC_BASEPRM_PLCIUNIT T_STR Input setup unit (PLC) -- -- RW A,B,C,D,E
M_SSEC_BASEPRM_CTRLUNIT T_STR Control unit O -- RW A,B,C,D,E
M_SSEC_BASEPRM_PLCCTRLUNIT T_STR Control unit (PLC) -- -- RW A,B,C,D,E
M_SSEC_BASEPRM_INIPLAN T_CHAR Initial plane selection O -- RW 1 to 3
M_SSEC_BASEPRM_BASE_AXIS_I T_STR Width/surface measure axis name O -- RW Axis address
(Base axis I)
M_SSEC_BASEPRM_BASE_AXIS_J T_STR Width/surface measure axis name O -- RW Axis address
(Base axis J)
M_SSEC_BASEPRM_BASE_AXIS_K T_STR Width/surface measure axis name O -- RW Axis address
(Base axis K)
M_SSEC_BASEPRM_HYOKOH1 T_STR Parallel axis I O -- RW Axis address
M_SSEC_BASEPRM_HTATEH1 T_STR Parallel axis J O -- RW Axis address
M_SSEC_BASEPRM_HTAKAH1 T_STR Parallel axis K O -- RW Axis address
M_SSEC_BASEPRM_CMDTYP T_CHAR Command type â–³ -- RW 1 to 8
M_SSEC_BASEPRM_PLCSEL T_CHAR Ladder selection -- -- RW 0 to 2
M_SSEC_BASEPRM_SP_NUM T_CHAR Number of spindles -- -- RW 0 to 4
M_SSEC_BASEPRM_MINCH T_LONG M_INCH -- -- RW 0,1
M_SSEC_BASEPRM_IINCH T_LONG Initial inch -- -- RW 0,1
M_SSEC_BASEPRM_PCINCH T_CHAR PLC axis inch command -- -- RW 0,1
M_SSEC_BASEPRM_LANG T_CHAR Select language displayed -- -- RW 0 to 3,11 to 20,22
M_SSEC_BASEPRM_AUXNO T_CHAR MR-J2-CT connections -- -- RW 0 to 4
M_SSEC_BASEPRM_NSKNO T_CHAR Mega torque motor connections -- -- RW 0 to 1666
M_SSEC_BASEPRM_MEMPRG T_CHAR Definition of program save area -- -- RW 0 to 7
M_SSEC_BASEPRM_MEMTOL T_LONG Tool compensation memory common -- -- RW 0,1
between part systems
M_SSEC_BASEPRM_MEMVAL T_LONG No. of common variables shared in -- -- RW 0,1
system designation
M_SSEC_BASEPRM_SETUP T_SHORT Activate setup processing -- -- RW 0,1,64
Bit selection
Command Data type Description PS AX RW Range
M_SSEC_MP_SELECT_BIT(x) T_LONG Bit selection (x=0 to 195) -- -- RW 0,1
Buffer correction
Command Data type Description PS AX RW Range
M_SSEC_BUFEDT_STATUS T_LONG Buffer correction status O -- R
M_SSEC_BUFEDT_PATH T_STR Buffer correction program path O -- R
M_SSEC_CCLK_BASE_RWW_NO1 T_SHORT 1st slot Remote register (RWw) refresh -- -- RW Depends on the device name The
device No. same with RX
M_SSEC_CCLK_BASE_SB_DEV1 T_CHAR 1st slot Special relay (SB) refresh -- -- RW M,L,B,D,W,R,SB
device name
M_SSEC_CCLK_BASE_SB_NO1 T_SHORT 1st slot Special relay (SB) refresh -- -- RW Depends on the device name SB0
device No. to SB1FF Others are the same
with RX
M_SSEC_CCLK_BASE_SW_DEV1 T_CHAR 1st slot Special relay (SW) refresh -- -- RW M,L,B,D,W,R,SW
device name
M_SSEC_CCLK_BASE_SW_NO1 T_SHORT 1st slot Special relay (SW) refresh -- -- RW Depends on the device name
device No. SW0 to SW1FF Others are the
same with RX
M_SSEC_CCLK_BASE_PRTCL_VER1 T_CHAR 1st slot Protocol version -- -- RW 0,1
M_SSEC_CCLK_BASE_EXCHG_NO2 T_CHAR 2nd slot Station No. -- -- RW -1 to 64
M_SSEC_CCLK_BASE_TRANS_SP2 T_CHAR 2nd slot Transmission rate and mode -- -- RW 0 to 14
M_SSEC_CCLK_BASE_ABNML_LINK2 T_CHAR 2nd slot Setting of data link faulty -- -- RW 0,1
station
M_SSEC_CCLK_BASE_PLC_STOP2 T_CHAR 2nd slot Setting at PLC STOP -- -- RW 0,1
M_SSEC_CCLK_BASE_OCCUP_BUREAUX2 T_CHAR 2nd slot Number of occupied stations -- -- RW 0 to 4
M_SSEC_CCLK_BASE_CYCLIC2 T_CHAR 2nd slot Extended cyclic setting -- -- RW 0,1,2,4,8
M_SSEC_CCLK_BASE_CONNECT_NUM2 T_CHAR 2nd slot Number of connected modules -- -- RW 0 to 64
M_SSEC_CCLK_BASE_RETRY2 T_CHAR 2nd slot Number of retries -- -- RW 0 to 7
M_SSEC_CCLK_BASE_AUTO_OPE_MATA2 T_CHAR 2nd slot Number of automatic return -- -- RW 0 to 10
modules
M_SSEC_CCLK_BASE_STANDBY_MASTER2 T_CHAR 2nd slot Standby master station -- -- RW 0 to 64
M_SSEC_CCLK_BASE_NC_DOWN2 T_CHAR 2nd slot Operation at NC down -- -- RW 0,1
M_SSEC_CCLK_BASE_SCAN_MODE2 T_CHAR 2nd slot Scan mode -- -- RW 0,1
M_SSEC_CCLK_BASE_DELAY_TIME2 T_CHAR 2nd slot Delay time -- -- RW Fixed to 0
M_SSEC_CCLK_BASE_RX_DEV2 T_CHAR 2nd slot Remote input (RX) refresh -- -- RW X,M,L,B,D,W,R
device name
M_SSEC_CCLK_BASE_RX_NO2 T_SHORT 2nd slot Remote input (RX) refresh -- -- RW Depends on the device name X0
device No. to X5FF M0 to M10239 L0 to
L511 B0 to B1FFF D0 to D2047
W0 to W1FFF R8300 to R9799
R9800 to R9899
M_SSEC_CCLK_BASE_RY_DEV2 T_CHAR 2nd slot Remote output (RY) refresh -- -- RW Y,M,L,B,D,W,R
device name
M_SSEC_CCLK_BASE_RY_NO2 T_SHORT 2nd slot Remote output (RY) refresh -- -- RW Depends on the device name Y0
device No. to Y5FF Others are the same with
RX
M_SSEC_CCLK_BASE_RWR_DEV2 T_CHAR 2nd slot Remote register (RWr) refresh -- -- RW M,L,B,D,W,R
device name
M_SSEC_CCLK_BASE_RWR_NO2 T_SHORT 2nd slot Remote register (RWr) refresh -- -- RW Depends on the device name The
device No. same with RX
M_SSEC_CCLK_BASE_RWW_DEV2 T_CHAR 2nd slot Remote register (RWw) -- -- RW M,L,B,D,W,R
refresh device name
M_SSEC_CCLK_BASE_RWW_NO2 T_SHORT 2nd slot Remote register (RWw) -- -- RW Depends on the device name The
refresh device No. same with RX
M_SSEC_CCLK_BASE_SB_DEV2 T_CHAR 2nd slot Special relay (SB) refresh -- -- RW M,L,B,D,W,R,SB
device name
M_SSEC_CCLK_BASE_SB_NO2 T_SHORT 2nd slot Special relay (SB) refresh -- -- RW Depends on the device name SB0
device No. to SB1FF Others are the same
with RX
M_SSEC_CCLK_BASE_SW_DEV2 T_CHAR 2nd slot Special relay (SW) refresh -- -- RW M,L,B,D,W,R,SW
device name
M_SSEC_CCLK_BASE_SW_NO2 T_SHORT 2nd slot Special relay (SW) refresh -- -- RW Depends on the device name
device No. SW0 to SW1FF Others are the
same with RX
M_SSEC_CCLK_BASE_PRTCL_VER2 T_CHAR 2nd slot Protocol version -- -- RW 0,1
M_SSEC_CCLK_BASE_EXCHG_NO3 T_CHAR 3rd slot Station No. -- -- RW -1 to 64
M_SSEC_CCLK_BASE_TRANS_SP3 T_CHAR 3rd slot Transmission rate and mode -- -- RW 0 to 14
CNC information
Command Data type Description PS AX RW Range
M_SSEC_SINFSS_AXIS_NUM_BASE T_CHAR The number of axes in a part system O -- R
(Basic configuration)
M_SSEC_SINFSS_CMVRS_NOS T_SHORT The number of sets of common O -- R
variable (#100-)
M_SSEC_SINFC_NC_AXIS T_CHAR The total number of NC axes (NC) -- -- R
M_SSEC_SINFC_ALL_AXIS T_CHAR The total number of control axes -- -- R
(NC+PLC+SP)
M_SSEC_SINFC_SP_AXIS T_CHAR The number of spindles -- -- R
M_SSEC_SINFC_PLC_AXIS T_CHAR The number of PLC axes -- -- R
M_SSEC_SINFC_AUX_AXIS T_CHAR The number of auxiliary axes -- -- R
M_SSEC_SINFC_FSYS_FORM File system format -- -- R
M_SSEC_SINFC_CMVRC_NOS T_LONG The number of sets of common -- -- R
variables (#500-)
M_SSEC_SINFC_PRSIZE T_SHORT Information of the max. number of -- -- R
machining programs to register
M_SSEC_SINFC_PWSPLY_AXIS T_CHAR The number of power supply axes -- -- R
(SV+SP)
M_SSEC_SINFC_PLCIDX_AXIS T_CHAR The number of PLC indexing axes -- -- R 0-
M_SSEC_SINFC_NCTYPE T_CHAR NC type -- -- R 0 to 1(0: MC, 1: Lathe)
M_SSEC_SINFC_PLCIF_TYPE T_CHAR PLC device allocation type (M6/M7) -- -- R 0 to 1(0: M6 Series, 1: M7)
M_SSEC_SINFC_4PALLET_ON T_CHAR Pallet 4-page registration enabled -- -- R 0 to 1(0: Disabled, 1: Enabled)
M_SSEC_SINFC_CMVRC_N400_ON T_LONG #400 address of common variables -- -- R 0 to 1
enabled
M_SSEC_SINFC_CROSSCOM_ON T_UCHAR #100100 address of common variables -- -- R 0 to 1
common for part systems enabled
M_SSEC_FINF_TOFS_NOS T_SHORT The number of tool compensation sets O -- R
M_SSEC_FINF_WOFS_NOS T_CHAR The number of workpiece offset sets O -- R
Counter
Command Data type Description PS AX RW Range
M_SSEC_CNTR_POS_WRK T_FLOATBIN/T_LONG Workpiece coordinate position counter O O R
M_SSEC_CNTR_POS_MCH T_FLOATBIN/T_LONG Machine position counter O O R
M_SSEC_CNTR_POS_CURRENT T_FLOATBIN/T_LONG Current position counter O O R
M_SSEC_CNTR_POS_RELATV T_FLOATBIN/T_LONG Relative position counter O O R
M_SSEC_CNTR_POS_PROGRAM T_FLOATBIN/T_LONG Program position counter O O R
M_SSEC_CNTR_DISTANCE T_FLOATBIN/T_LONG Remaining command O O R
M_SSEC_CNTR_SKIP T_FLOATBIN/T_LONG Skip coordinate counter (Workpiece O O R
coordinate)
M_SSEC_CNTR_INTER T_FLOATBIN/T_LONG Manual interruption amount 1 (ABS Off) O O R
M_SSEC_CNTR_INTER2 T_FLOATBIN/T_LONG Manual interruption amount 2 (ABS On) O O R
M_SSEC_CNTR_NEXT T_FLOATBIN/T_LONG Next command O O R
M_SSEC_CNTR_POS_RESTART T_FLOATBIN/T_LONG Restart position counter (Workpiece O O R
coordinate)
M_SSEC_CNTR_POS_RE_DIST T_FLOATBIN/T_LONG Remaining restart distance counter O O R
M_SSEC_CNTR_POS_RE_MCH T_FLOATBIN/T_LONG Restart position counter (Machine O O R
coordinate)
M_SSEC_CNTR_POS_PROG2 T_FLOATBIN/T_LONG Program position counter 2 O O R
M_SSEC_CNTR_POS_TLM T_FLOATBIN/T_LONG TLM position counter O O R
M_SSEC_CNTR_TLM_SKIP T_FLOATBIN/T_LONG TLM skip position counter (mxtlms) O O R
M_SSEC_CNTR_TLM T_FLOATBIN/T_LONG TLM position counter (mxtlm) O O R
M_SSEC_CNTR_MXSKPM T_FLOATBIN/T_LONG Skip coordinate counter (Machine O O R
coordinate)
M_SSEC_CNTR_MXSKPR T_FLOATBIN/T_LONG Remaining skip distance counter O O R
M_SSEC_CNTR_LM T_LONG Interpolation combined vector length O -- R
(lm)
M_SSEC_CNTR_POS_CURRENT_B T_FLOATBIN/T_LONG Current position B counter O O R
M_SSEC_CNTR_SKIP_WORK T_FLOATBIN/T_LONG Skip machine value (manual skip O O R -
position)
M_SSEC_CNTR_SKP_COORD_POS T_FLOATBIN Skip coordinate position (skip O O R Special
coordinate counter)
M_SSEC_CNTR_MEAS_POS T_FLOATBIN Measure position O O R Special
M_SSEC_CNTR_POS_TIP_M T_FLOATBIN Tip machine position O O R -
M_SSEC_CNTR_POS_TIP_W T_FLOATBIN Tip workpiece position O O R -
Cumulative time
Command Data type Description PS AX RW Range
M_SSEC_RTIME_POWER_ON T_LONG/T_STR Power ON time -- -- RW (Special)
M_SSEC_RTIME_AUTO_OP T_LONG/T_STR Automatic operation time -- -- RW (Special)
M_SSEC_RTIME_AUTO_STL T_LONG/T_STR Automatic start up time -- -- RW (Special)
M_SSEC_RTIME_EXT1 T_LONG/T_STR External cumulative time 1 -- -- RW (Special)
M_SSEC_RTIME_EXT2 T_LONG/T_STR External cumulative time 2 -- -- RW (Special)
M_SSEC_RTIME_DATE T_LONG/T_STR Date -- -- RW (Special)
M_SSEC_RTIME_TIME T_LONG/T_STR Time -- -- RW (Special)
M_SSEC_RTIME_CYCLE T_LONG/T_STR Cycle time O -- R (Special)
M_SSEC_RTIME_PROCESS_TIME T_LONG Machining time calculation -- -- RW 0 to 35999999000 (Setting is only
0)
Ethernet parameter
Command Data type Description PS AX RW Range
M_SSEC_UPETHER_ETHERNET T_CHAR Start of service -- -- RW 0,1
M_SSEC_UPETHER_IPADDR T_STR IP address -- -- RW Alphanumeric characters, symbols
M_SSEC_UPETHER_SUBNET T_STR Subnet mask -- -- RW Alphanumeric characters, symbols
M_SSEC_UPETHER_GATEWAY T_STR Gateway -- -- RW Alphanumeric characters, symbols
M_SSEC_UPETHER_PORTNUMBER T_LONG Port No. -- -- RW 0 to 9999
M_SSEC_UPETHER_BEFORE_HOSTADDR T_STR Ethernet communication parameter -- -- RW Alphanumeric characters, symbols
before conversion (Host address)
M_SSEC_UPETHER_HOSTNUMBER T_LONG Host's port No. -- -- RW 0 to 9999
M_SSEC_UPETHER_LOCAL_IPADDR T_STR Local IP Address - - RW 0.0.0.0 to 255.255.255.255
M_SSEC_UPETHER_LOCAL_SUBNET T_STR Local Subnetmask - - RW 0.0.0.0 to 255.255.255.255
M_SSEC_UPETHER_PC_AUTO_IPADDR T_CHAR IP address automatic setting -- -- RW 0,1
M_SSEC_UPETHER_PC_IPADDR T_STR IP address (PC) -- -- RW Within 15 letters, numerics in dot
notation
M_SSEC_UPETHER_PC_SUBNET T_STR Subnet mask (PC) -- -- RW Within 15 letters, numerics in dot
notation
M_SSEC_UPETHER_PC_GATEWAY T_STR Gateway (PC) -- -- RW Within 15 letters, numerics in dot
notation
M_SSEC_UPETHER_TIMEOUT T_SHORT Time-out -- -- RW 10 to 99
M_SSEC_UPETHER_USE_HOSTNUMBER T_CHAR Host No. to use -- -- RW 1 to 4
M_SSEC_UPETHER_HOST_LOGINNAME(x) T_STR User name (Host A to D) (x=0 to 3) -- -- RW Within 15 letters
M_SSEC_UPETHER_HOST_PWORD(x) T_STR Password (Host A to D) (x=0 to 3) -- -- RW Within 15 letters
M_SSEC_UPETHER_HOST_DIRPATH(x) T_STR Directory (Host A to D) (x=0 to 3) -- -- RW Within 63 letters (M75X: Within
31 letters)
M_SSEC_UPETHER_HOST_IPADDR(x) T_STR Host address (Host A to D) (x=0 to 3) -- -- RW Within 15 letters
M_SSEC_UPETHER_HOST_TYPE(x) T_CHAR Host type (Host 1 to 4) (x=0 to 3) -- -- RW 0 to 2
M_SSEC_UPETHER_HOST_WORD_FILE(x) T_SHORT Host word position: File (Host 1 to 4) -- -- RW 0 to 100
(x=0 to 3)
M_SSEC_UPETHER_HOST_WORD_SIZE(x) T_SHORT Host word position: Size (Host 1 to 4) -- -- RW 0 to 100
(x=0 to 3)
M_SSEC_UPETHER_HOST_WORD_DIR(x) T_SHORT Host word position: <DIR> (Host 1 to -- -- RW 0 to 100
4) (x=0 to 3)
M_SSEC_UPETHER_HOST_WORD_CMT(x) T_SHORT Host word position: Comment (Host 1 -- -- RW 0 to 100
to 4) (x=0 to 3)
F modal
Command Data type Description PS AX RW Range
M_SSEC_FMDL_FA T_FLOATBIN Program command F modal (FA) O -- R
M_SSEC_FMDL_FM T_FLOATBIN Manual feedrate (FM) O -- R
M_SSEC_FMDL_FS T_FLOATBIN Synchronous feedrate (FS) O -- R
M_SSEC_FMDL_FE T_FLOATBIN Thread cutting lead (FE) O -- R
M_SSEC_FMDL_DWELL T_FLOATBIN Remaining dwell time O -- R
M_SSEC_FMDL_G96S(x) T_LONG Constant surface speed control O -- R
(Surface speed S) (x=1 to 6)
File information
Command Data type Description PS AX RW Range
M_SSEC_FILEINF_REG_PROG_NOS T_LONG The number of machining programs to -- -- R
register
M_SSEC_FILEINF_USED_PROG_NOS T_LONG The number of remaining machining -- -- R
programs
M_SSEC_FILEINF_CAPA_CHAR_NOS T_LONG Machining program character capacity -- -- R
M_SSEC_FILEINF_FREE_CHAR_NOS T_LONG The number of remaining characters in -- -- R
machining program
M_SSEC_FILEINF_TRANS_SIZE T_LONG Transferred data size of melCopyFile -- -- R
G modal
Command Data type Description PS AX RW Range
M_SSEC_GMDL_G(x) T_DOUBLE G code (x=Group1 to 21) O -- R
M_SSEC_GMDL_GEO_MC_NO T_SHORT Tool compensation No. of shape O -- R
(diameter) compensation modal
M_SSEC_GMDL_GEO_RADIUS T_LONG Compensation amount of shape O -- R
(diameter) compensation modal
M_SSEC_GMDL_GEO_WEAR T_LONG Wear amount of shape (diameter) O -- R
compensation modal
M_SSEC_GMDL_WEAR_MC_NO T_SHORT Tool compensation No. of diameter O -- R
compensation modal
M_SSEC_GMDL_TPOS T_FLOATBIN/T_LONG Position compensation vector of tool O O R
being used
M_SSEC_GMDL_LENG_MC_NO T_SHORT Tool compensation No. of length O -- R
compensation modal
M_SSEC_GMDL_LENG_AXIS T_STR Axis name of length compensation O O R
modal
M_SSEC_GMDL_LENG_OFFSET T_LONG Compensation amount of length O -- R
compensation modal
M_SSEC_GMDL_LENG_WEAR T_LONG Wear amount of length compensation O -- R
modal
M_SSEC_GMDL_H_COMP_AL T_LONG Information of axis in length O -- R
compensation (All axes)
M_SSEC_GMDL_H_COMP_NO T_LONG Tool compensation No. of length O O R
compensation modal
M_SSEC_GMDL_SCALE_MAG T_FLOATBIN/T_LONG Scaling magnification (G50P_) [Grp11] O -- R
M_SSEC_GMDL_COORD_ROT T_FLOATBIN/T_LONG Coordinate rotation angle (G68R_) O -- R
[Grp16]
M_SSEC_GMDL_H_SPEED_MODE T_LONG High speed machining mode (G5P_) O -- R
M_SSEC_GMDL_GMOV T_CHAR gmov cutting/non-cutting command O -- R
M_SSEC_GMDL_AWOFS_NO T_CHAR Extended workpiece selection O -- R
(G54.1P_)
M_SSEC_GMDL_CUTTING_STS T_SHORT In cutting information O -- R
M_SSEC_GMDL_SCALE_MAG2 T_FLOATBIN Scaling magnification (G50P_)[Grp11] O -- R
(Compatible with Magic)
Hardware configuration
Command Data type Description PS AX RW Range
M_SSEC_HWCFG_RIO_UNIT(x) T_STR RIO unit 1 to 8 -- -- R
M_SSEC_HWCFG_TERMINAL_RIO(x) T_STR Terminal RIO unit 1 to 4 -- -- R
M_SSEC_HWCFG_MAIN_UNIT T_STR Control unit (NC card) -- -- R
M_SSEC_HWCFG_EXT_UNIT T_STR Extension unit -- -- R
M_SSEC_HWCFG_TERMINAL T_STR Terminal display (For M7) -- -- R
M_SSEC_HWCFG_OPT_CARD T_STR Extension bus for optional card -- -- R
(OPTION CARD) (For M7)
M_SSEC_HWCFG_ATT_CARD T_STR External interface for CPUCARD -- -- R
(Magic68)
M_SSEC_HWCFG_OPE_CARD T_STR External interface for CPUCARD (For -- -- R
M7)
M_SSEC_HWCFG_RIO_NOS T_STR The number of RIO units (For M7) -- -- R
M_SSEC_HWCFG_RIO_ALL(x) T_STR RIO unit (For M7) (x=1 to 32) -- -- R
M_SSEC_HWCFG_CNC_UNITS(x) T_STR Control unit 1 to 4(M7)(x=1 to 4) -- -- R
M_SSEC_HWCFG_EXT_UNITS(x) T_STR Extension unit 1 to 4(M7)(x=1 to 4) -- -- R
M_SSEC_HWCFG_CNC_UNITS_VER(x) T_STR Control unit hardware version 1 to -- -- R
4(x=1 to 4)
M_SSEC_HWCFG_RAS_BATTERY_VOLT T_SHORT Battery voltage -- -- R 0: Normal 1: Battery low 2:
Encoder error 3: No voltage
M_SSEC_HWCFG_RAS_BATTERY_STS T_CHAR Battery voltage status -- -- R 0: Normal 1: Warning 2: Alarm
Input/Output parameter
Command Data type Description PS AX RW Range
M_SSEC_UPIO_SINPORT T_CHAR Data input <Port No.> -- -- RW 1 to 2
M_SSEC_UPIO_SINDEV T_CHAR Data input <Device No.> -- -- RW 0 to 4
M_SSEC_UPIO_SOTPORT T_CHAR Data output <Port No.> -- -- RW 1 to 2
M_SSEC_UPIO_SOTDEV T_CHAR Data output <Device No.> -- -- RW 0 to 4
M_SSEC_UPIO_SNCPORT T_CHAR Tape operation <Port No.> -- -- RW 1 to 2
M_SSEC_UPIO_SNCDEV T_CHAR Tape operation <Device No.> -- -- RW 0 to 4
M_SSEC_UPIO_MCRPORT T_CHAR Macro print <Port No.> -- -- RW 1 to 2
M_SSEC_UPIO_MCRDEV T_CHAR Macro print <Device No.> -- -- RW 0 to 4
M_SSEC_UPIO_PLCPORT T_CHAR PLC input/output <Port No.> -- -- RW 1 to 2
M_SSEC_UPIO_PLCDEV T_CHAR PLC input/output <Device No.> -- -- RW 0 to 4
M_SSEC_UPIO_RPGPORT T_CHAR Remote program input <Port No.> -- -- RW 1 to 2
M_SSEC_UPIO_RPGDEV T_CHAR Remote program input <Device No.> -- -- RW 0 to 4
M_SSEC_UPIO_EXTPORT T_CHAR External unit <Port No.> -- -- RW 1 to 2
M_SSEC_UPIO_EXTDEV T_CHAR External unit <Device No.> -- -- RW 0 to 4
M_SSEC_UPIO_SIOTP1_DEVNAME T_STR Device 1 Device name -- -- RW 3 letters (Alphanumeric
characters, symbols)
M_SSEC_UPIO_SIOTP1_BAUDRT T_CHAR Device 1 Baud rate -- -- RW 0 to 7
M_SSEC_UPIO_SIOTP1_STOPBT T_CHAR Device 1 Stop bit -- -- RW 1 to 3
M_SSEC_UPIO_SIOTP1_PARITYB T_CHAR Device 1 Parity enabled -- -- RW 0,1
M_SSEC_UPIO_SIOTP1_PARITYA T_CHAR Device 1 Even parity -- -- RW 0,1
M_SSEC_UPIO_SIOTP1_LENCH T_CHAR Device 1 Character length -- -- RW 0 to 3
M_SSEC_UPIO_SIOTP1_TERMTP T_CHAR Device 1 Terminator type -- -- RW 0 to 3
M_SSEC_UPIO_SIOTP1_HANDTP T_CHAR Device 1 Hand shake -- -- RW 1 to 4
M_SSEC_UPIO_SIOTP1_DCPARI T_CHAR Device 1 DC code parity -- -- RW 0,1
M_SSEC_UPIO_SIOTP1_FEEDFLG T_CHAR Device 1 DC2/DC4 output -- -- RW 0 to 3
M_SSEC_UPIO_SIOTP1_CROUT T_CHAR Device 1 CR output -- -- RW 0,1
M_SSEC_UPIO_SIOTP1_EIAOUT T_LONG Device 1 EIA output -- -- RW 0,1
M_SSEC_UPIO_SIOTP1_FEEDCHR T_SHORT Device 1 Feed character -- -- RW 0 to 999
M_SSEC_UPIO_SIOTP1_PARITYV T_LONG Device 1 Parity V -- -- RW 0,1
M_SSEC_UPIO_SIOTP1_TOUT T_SHORT Device 1 Time-out -- -- RW 0 to 30
M_SSEC_UPIO_SIOTP1_DROFF T_CHAR Device 1 DR OFF -- -- RW 0,1
M_SSEC_UPIO_SIOTP1_DATASCII T_LONG Device 1 Data ASCII -- -- RW 0,1
Key history
Command Data type Description PS AX RW Range
M_SSEC_KEYHIST_SAMPSTS T_CHAR Collection status of sampling -- -- R 0,1,2
M_SSEC_KEYHIST_HISTSTS T_CHAR Collection status of history -- -- R 0,1
M_SSEC_KEYHIST_SPEC_SYS T_CHAR Specification-Part system -- -- RW 0x00 to 0x0F
M_SSEC_KEYHIST_SPEC_SP T_CHAR Specification-Spindle -- -- RW 0x00 to 0x0F
M_SSEC_KEYHIST_SPEC_SV T_SHORT Specification-Servo -- -- RW 0x0000 to 0xFFFF
M_SSEC_KEYHIST_DATA_HW T_LONG Data-Hardware configuration -- -- RW 0,1
M_SSEC_KEYHIST_DATA_SW T_LONG Data-Software configuration -- -- RW 0,1
M_SSEC_KEYHIST_DATA_KEYHIST T_LONG Data-Key history -- -- RW 0,1
M_SSEC_KEYHIST_DATA_ALARMHIST T_LONG Data-Alarm history -- -- RW 0,1
M_SSEC_KEYHIST_DATA_PLCIOHIST T_LONG Data-PLC input/output signal history -- -- RW 0,1
M_SSEC_KEYHIST_DATA_ACINHIST T_LONG Data-AC input power supply error -- -- RW 0,1
history
M_SSEC_KEYHIST_DATA_SPDATA1 T_LONG Data-Spindle data 1 -- -- RW 0,1
M_SSEC_KEYHIST_DATA_SPDATA2 T_LONG Data-Spindle data 2 -- -- RW 0,1
M_SSEC_KEYHIST_DATA_SVDATA1 T_LONG Data-Servo data 1 -- -- RW 0,1
M_SSEC_KEYHIST_DATA_SVDATA2 T_LONG Data-Servo data 2 -- -- RW 0,1
M_SSEC_KEYHIST_DATA_MODALINFO T_LONG Data-Modal information -- -- RW 0,1
M_SSEC_KEYHIST_DATA_PRGDATA T_LONG Data-Program data -- -- RW 0,1
M_SSEC_KEYHIST_DATA_COORDDATA T_LONG Data-Coordination data -- -- RW 0,1
M_SSEC_KEYHIST_SAMP_TRIGGER T_LONG Request of sampling start/stop -- -- W 0,1
(Manual)
M_SSEC_KEYHIST_HIST_TRIGGER T_LONG Request of history start/stop (Manual) -- -- W 0,1
M_SSEC_KEYHIST_PWON T_LONG Request of data collection start/stop at -- -- W 0,1
power ON
M_SSEC_KEYHIST_SAMP_CLR T_LONG Sampling data clear -- -- W 1
M_SSEC_KEYHIST_HIST_CLR T_LONG History data clear -- -- W 1
M_SSEC_KEYHIST_ALMHIST_CLR T_LONG Alarm history data clear - -- W 1
Local variable
Command Data type Description PS AX RW Range
M_SSEC_LOCVR_LV0_DAT(x) T_DOUBLE Local variable (Level0) (x=1 to 33) O -- R
M_SSEC_LOCVR_LV1_DAT(x) T_DOUBLE Local variable (Level1) (x=1 to 33) O -- R
M_SSEC_LOCVR_LV2_DAT(x) T_DOUBLE Local variable (Level2) (x=1 to 33) O -- R
M_SSEC_LOCVR_LV3_DAT(x) T_DOUBLE Local variable (Level3) (x=1 to 33) O -- R
M_SSEC_LOCVR_LV4_DAT(x) T_DOUBLE Local variable (Level4) (x=1 to 33) O -- R
M_SSEC_LOCVR_EMPTY_VAL T_DOUBLE Local variable empty variable O -- R
Macro list
Command Data type Description PS AX RW Range
M_SSEC_MPLMAC_M01_TMCODE T_SHORT M[01] code -- -- RW 0 to 9999
M_SSEC_MPLMAC_M01_TMMACROT T_CHAR M[01] type -- -- RW 0 to 3
M_SSEC_MPLMAC_M01_TMMACRO T_STR M[01] program No. -- -- RW 0 to 999999999
M_SSEC_MPLMAC_M02_TMCODE T_SHORT M[02] code -- -- RW 0 to 9999
M_SSEC_MPLMAC_M02_TMMACROT T_CHAR M[02] type -- -- RW 0 to 3
M_SSEC_MPLMAC_M02_TMMACRO T_STR M[02] program No. -- -- RW 0 to 999999999
M_SSEC_MPLMAC_M03_TMCODE T_SHORT M[03] code -- -- RW 0 to 9999
M_SSEC_MPLMAC_M03_TMMACROT T_CHAR M[03] type -- -- RW 0 to 3
M_SSEC_MPLMAC_M03_TMMACRO T_STR M[03] program No. -- -- RW 0 to 999999999
M_SSEC_MPLMAC_M04_TMCODE T_SHORT M[04] code -- -- RW 0 to 9999
M_SSEC_MPLMAC_M04_TMMACROT T_CHAR M[04] type -- -- RW 0 to 3
M_SSEC_MPLMAC_M04_TMMACRO T_STR M[04] program No. -- -- RW 0 to 999999999
M_SSEC_MPLMAC_M05_TMCODE T_SHORT M[05] code -- -- RW 0 to 9999
M_SSEC_MPLMAC_M05_TMMACROT T_CHAR M[05] type -- -- RW 0 to 3
M_SSEC_MPLMAC_M05_TMMACRO T_STR M[05] program No. -- -- RW 0 to 999999999
M_SSEC_MPLMAC_M06_TMCODE T_SHORT M[06] code -- -- RW 0 to 9999
M_SSEC_MPLMAC_M06_TMMACROT T_CHAR M[06] type -- -- RW 0 to 3
M_SSEC_MPLMAC_M06_TMMACRO T_STR M[06] program No. -- -- RW 0 to 999999999
M_SSEC_MPLMAC_M07_TMCODE T_SHORT M[07] code -- -- RW 0 to 9999
M_SSEC_MPLMAC_M07_TMMACROT T_CHAR M[07] type -- -- RW 0 to 3
M_SSEC_MPLMAC_M07_TMMACRO T_STR M[07] program No. -- -- RW 0 to 999999999
M_SSEC_MPLMAC_M08_TMCODE T_SHORT M[08] code -- -- RW 0 to 9999
M_SSEC_MPLMAC_M08_TMMACROT T_CHAR M[08] type -- -- RW 0 to 3
M_SSEC_MPLMAC_M08_TMMACRO T_STR M[08] program No. -- -- RW 0 to 999999999
M_SSEC_MPLMAC_M09_TMCODE T_SHORT M[09] code -- -- RW 0 to 9999
M_SSEC_MPLMAC_M09_TMMACROT T_CHAR M[09] type -- -- RW 0 to 3
M_SSEC_MPLMAC_M09_TMMACRO T_STR M[09] program No. -- -- RW 0 to 999999999
M_SSEC_MPLMAC_M10_TMCODE T_SHORT M[10] code -- -- RW 0 to 9999
M_SSEC_MPLMAC_M10_TMMACROT T_CHAR M[10] type -- -- RW 0 to 3
M_SSEC_MPLMAC_M10_TMMACRO T_STR M[10] program No. -- -- RW 0 to 999999999
M_SSEC_MPLMAC_TBMACROT T_CHAR M2mac type -- -- RW 0 to 3
M_SSEC_MPLMAC_TBMACRO T_STR M2mac program No. -- -- RW 0 to 999999999
MSTB modal
Command Data type Description PS AX RW Range
M_SSEC_MSTBMDL_S(x) T_LONG S modal (S1 to S6) (x=1 to 6) -- -- R
M_SSEC_MSTBMDL_T(x) T_LONG T modal (T1 to T2) (x=1 to 2) -- -- R
M_SSEC_MSTBMDL_M(x) T_LONG M modal (M1 to M4) (x=1 to 4) -- -- R
M_SSEC_MSTBMDL_B(x) T_LONG B modal (B1 to B4) (x=1 to 4) -- -- R
Operation parameter
Command Data type Description PS AX RW Range
M_SSEC_UPOPE_COUNT_KIND(x) T_UCHAR Counter type 1 to 6 (x=1 to 6) -- -- RW 0 to 255
M_SSEC_UPOPE_AUT_MANU_SW T_CHAR Display switch between -- -- RW 0 to 2
automatic/manual
M_SSEC_UPOPE_EDIT_UNDO T_CHAR Edit undo enabled -- -- RW 0,1
M_SSEC_UPOPE_TOPSEARCH_AUTO T_CHAR Auto top search -- -- RW 0,1
M_SSEC_UPOPE_AUTO_BACKUP_DAY1 T_CHAR Auto backup day 1 -- -- RW -1 to 31
M_SSEC_UPOPE_AUTO_BACKUP_DAY2 T_CHAR Auto backup day 2 -- -- RW 0 to 31
M_SSEC_UPOPE_AUTO_BACKUP_DAY3 T_CHAR Auto backup day 3 -- -- RW 0 to 31
M_SSEC_UPOPE_AUTO_BACKUP_DAY4 T_CHAR Auto backup day 4 -- -- RW 0 to 31
M_SSEC_UPOPE_AUTO_BACKUP_DEV T_CHAR Auto backup device -- -- RW 0 to 2
M_SSEC_UPOPE_3D_TOFS_SELECT T_CHAR 3D tool ofs select -- -- RW 0,1
M_SSEC_UPOPE_MASS_EDIT_SELECT T_CHAR Mass edit select -- -- RW 0,1
M_SSEC_UPOPE_TREG_REPEAT_INVALID T_CHAR T-register duplication check disabled -- -- RW 0,1
M_SSEC_UPOPE_HIDE_EDIT_IO_MENU T_CHAR Hide Edit-IO menu -- -- RW 0,1
M_SSEC_UPOPE_MEAS_CONFIRM_MSG T_CHAR Measure-Confirmation message exists -- -- RW 0,1
M_SSEC_UPOPE_SYS1_SPNO T_CHAR Spindle No. on part sys 1 display -- -- RW 0x00 to 0x66
M_SSEC_UPOPE_SYS2_SPNO T_CHAR Spindle No. on part sys 2 display -- -- RW 0x00 to 0x66
M_SSEC_UPOPE_SYS3_SPNO T_CHAR Spindle No. on part sys 3 display -- -- RW 0x00 to 0x66
M_SSEC_UPOPE_SYS4_SPNO T_CHAR Spindle No. on part sys 4 display -- -- RW 0x00 to 0x66
M_SSEC_UPOPE_OFS_ABSINPUT T_CHAR 5Input menu disabled: Compensation -- -- RW 0,1
M_SSEC_UPOPE_VAR_ABSINPUT T_CHAR 5Input menu disabled: Variable -- -- RW 0,1
M_SSEC_UPOPE_DIS_SET_LIMIT T_CHAR Remote display/setting operation limit -- -- RW 0 to 2
M_SSEC_UPOPE_HIDE_MEAS_SCRN T_CHAR Hide measure screen -- -- RW 0,1
M_SSEC_UPOPE_TOOLOFS_INPUT T_CHAR Prohibit shape compensation amount -- -- RW 0,1
setting
M_SSEC_UPOPE_WEAROFS_INPUT T_CHAR Prohibit wear compensation amount -- -- RW 0,1
setting
Operation status
Command Data type Description PS AX RW Range
M_SSEC_EXST_MACRO_EXEC_LV T_CHAR Macro execution level O -- R
M_SSEC_EXST_BUSY_COLLATION T_LONG Executing verification stop O -- RW 0
M_SSEC_EXST_COLLATION_O T_STR Verification stop O No. O -- R
M_SSEC_EXST_COLLATION_N T_LONG Verification stop N No. O -- R
M_SSEC_EXST_COLLATION_B T_LONG Verification stop B No. O -- R
M_SSEC_EXST_COLLATION_PATH T_STR Verification stop path name O -- R
M_SSEC_EXST_NC_RUN_STATUS T_SHORT Operation status 1 (Operation status) O -- R 0: RST, 1: EMG, 2: RDY, 3: AUT,4:
SYN,5: CRS,6: BST,7: HLD
M_SSEC_EXST_NC_RUN_MODE T_SHORT Operation status 2 (Operation mode) O -- R 0: MEM,1: 232,2: LNK,3: MDI,4:
PC,5: MNL,6: JOG,7: J+H,8: R+H,
9: HDL,10: STP,11: STP,12:
ZRN,13: DRT,14: INI,15: NON,16:
LIN
M_SSEC_EXST_AUTO_STL T_LONG Automatic operation in progress O -- R
M_SSEC_EXST_OPERATION T_LONG Executing automatic operation O -- R
M_SSEC_EXST_STOP_OPERATION T_LONG Automatic operation is stopped O -- R
M_SSEC_EXST_LOCK_KEY_1 T_LONG Data lock key 1 O -- R
M_SSEC_EXST_LOCK_KEY_2 T_LONG Data lock key 2 O -- R
M_SSEC_EXST_LOCK_KEY_3 T_LONG Data lock key 3 O -- R
M_SSEC_EXST_PISW1 T_SHORT External input signal 1 O -- R
M_SSEC_EXST_PIJSP T_CHAR JOG mode (special) signal O -- R
M_SSEC_EXST_PODT1 T_SHORT NC status output signal 1 O -- R
M_SSEC_EXST_POAL T_CHAR Alarm status signal O -- R
M_SSEC_EXST_AUTO_MOD T_CHAR Operation (automatic) mode related O -- R
signal
M_SSEC_EXST_MANU_MOD T_CHAR Operation (manual) mode related signal O -- R
M_SSEC_EXST_RST_STS T_LONG Restart search status O -- R
M_SSEC_EXST_RST_TP1STS T_LONG Restart search type 1 enabled O -- R
M_SSEC_EXST_EXSRCH_STS T_LONG Extended operation search status O -- R
M_SSEC_EXST_EXSRCH_LINE T_LONG Current line number during search O -- R
M_SSEC_EXST_CHECK_STS T_LONG Check status O -- R
M_SSEC_EXST_PRON T_LONG Parameter flag to demand power ON -- -- R
again
PLC constant
Command Data type Description PS AX RW Range
M_SSEC_MP_PLC_CONST(x) T_LONG PLC constant (x=0 to 95 / [M7] x=0 to -- -- RW -99999999 to 99999999
899)
PLC counter
Command Data type Description PS AX RW Range
M_SSEC_MP_PLC_COUNTER(x) T_SHORT Counter (x=0 to 23 / [M7] x=0 to 255) -- -- RW 0 to 65535
M_SSEC_MP_PLC_COUNTER_NOS T_SHORT Number of times of PLC counter -- -- R
(variable) (Only for M7)
M_SSEC_MP_PLC_COUNTER_STS(x) T_CHAR PLC counter device used status (x=0 to -- -- R BIT0 - ON: Used/OFF: Not used
256) BIT1 - ON: Constant/OFF: Variable
PLC switch
Command Data type Description PS AX RW Range
M_SSEC_UP_PLC_SWITCH_X(x) T_CHAR PLC switch X (IN) (x=1 to 32) -- -- RW 0,1
M_SSEC_UP_PLC_SWITCH_Y(x) T_CHAR PLC switch Y (OUT) (x=1 to 32) -- -- R
M_SSEC_UP_PLCSW_IN0 T_SHORT PLC switch X (IN) 1 to 16 -- -- RW 0x0000 to 0xFFFF
M_SSEC_UP_PLCSW_IN1 T_SHORT PLC switch X (IN) 17 to 32 -- -- RW 0x0000 to 0xFFFF
M_SSEC_UP_PLCSW_OUT0 T_SHORT PLC switch Y (OUT) 1 to 16 -- -- RW 0x0000 to 0xFFFF
M_SSEC_UP_PLCSW_OUT1 T_SHORT PLC switch Y (OUT) 17 to 32 -- -- R 0x0000 to 0xFFFF
PLC timer
Command Data type Description PS AX RW Range
M_SSEC_MP_PLC_TIMER10(x) T_LONG 10ms timer <10ms> (x=0 to 15 / [M7] -- -- RW 0 to 65535
x=0 to 703)
M_SSEC_MP_PLC_TIMER100(x) T_LONG 100ms timer <100ms> (x=0 to 79 / -- -- RW 0 to 65535
[M7] x=0 to 703)
M_SSEC_MP_PLC_TIMER100INC(x) T_LONG 100ms cumulative timer <100msINC> -- -- RW 0 to 65535
(x=0 to 7 / [M7] x=0 to 63)
M_SSEC_MP_PLC_EX_TIMER10(x) T_LONG 10ms additional extension timer -- -- RW 0 to 65535
<10ms> (x=0 to 399 / [M7]
Unavailable)
M_SSEC_MP_PLC_TIMER_NOS T_SHORT Number of times of PLC timers -- -- R
(variable) (Only for M7)
M_SSEC_MP_PLC_TIMERINC_NOS T_SHORT Number of times of PLC cumulative -- -- R
timer (variable) (Only for M7)
M_SSEC_MP_PLC_TIMER_STS(x) T_CHAR PLC timer device used status (x=0 to -- -- R BIT0 - ON: Used/OFF: Not used
703) BIT1 - ON: Constant/OFF: Variable
BIT2 - ON: 10ms/OFF: 100ms
M_SSEC_MP_PLC_TIMER_INC_STS(x) T_CHAR PLC cumulative timer device used -- -- R BIT0 - ON: Used/OFF: Not used
status (x=0 to 63) BIT1 - ON: Constant/OFF: Variable
Position switch
Command Data type Description PS AX RW Range
M_SSEC_MPPOSW_CKPSW T_CHAR PSW switch -- -- RW 0,1
M_SSEC_MPPOSW_PSW1_PAXNAM T_STR 1st position switch axis name O -- RW Character string (Axis address of
#1013)
M_SSEC_MPPOSW_PSW1_DOG1 T_FLOATBIN/T_LONG 1st position switch hypothetical dog O -- RW ±99999.999
position 1
M_SSEC_MPPOSW_PSW1_DOG2 T_FLOATBIN/T_LONG 1st position switch hypothetical dog O -- RW ±99999.999
position 2
M_SSEC_MPPOSW_PSW1_CKTYP T_CHAR 1st position switch PSW check method O -- RW 0,1
switch
M_SSEC_MPPOSW_PSW2_PAXNAM T_STR 2nd position switch axis name O -- RW Character string (Axis address of
#1013)
M_SSEC_MPPOSW_PSW2_DOG1 T_FLOATBIN/T_LONG 2nd position switch hypothetical dog O -- RW ±99999.999
position 1
M_SSEC_MPPOSW_PSW2_DOG2 T_FLOATBIN/T_LONG 2nd position switch hypothetical dog O -- RW ±99999.999
position 2
M_SSEC_MPPOSW_PSW2_CKTYP T_CHAR 2nd position switch PSW check O -- RW 0,1
method switch
M_SSEC_MPPOSW_PSW3_PAXNAM T_STR 3rd position switch axis name O -- RW Character string (Axis address of
#1013)
M_SSEC_MPPOSW_PSW3_DOG1 T_FLOATBIN/T_LONG 3rd position switch hypothetical dog O -- RW ±99999.999
position 1
M_SSEC_MPPOSW_PSW3_DOG2 T_FLOATBIN/T_LONG 3rd position switch hypothetical dog O -- RW ±99999.999
position 2
M_SSEC_MPPOSW_PSW3_CKTYP T_CHAR 3rd position switch PSW check method O -- RW 0,1
switch
M_SSEC_MPPOSW_PSW4_PAXNAM T_STR 4th position switch axis name O -- RW Character string (Axis address of
#1013)
M_SSEC_MPPOSW_PSW4_DOG1 T_FLOATBIN/T_LONG 4th position switch hypothetical dog O -- RW ±99999.999
position 1
M_SSEC_MPPOSW_PSW4_DOG2 T_FLOATBIN/T_LONG 4th position switch hypothetical dog O -- RW ±99999.999
position 2
M_SSEC_MPPOSW_PSW4_CKTYP T_CHAR 4th position switch PSW check method O -- RW 0,1
switch
M_SSEC_MPPOSW_PSW5_PAXNAM T_STR 5th position switch axis name O -- RW Character string (Axis address of
#1013)
M_SSEC_MPPOSW_PSW5_DOG1 T_FLOATBIN/T_LONG 5th position switch hypothetical dog O -- RW ±99999.999
position 1
M_SSEC_MPPOSW_PSW5_DOG2 T_FLOATBIN/T_LONG 5th position switch hypothetical dog O -- RW ±99999.999
position 2
M_SSEC_MPPOSW_PSW5_CKTYP T_CHAR 5th position switch PSW check method O -- RW 0,1
switch
M_SSEC_MPPOSW_PSW6_PAXNAM T_STR 6th position switch axis name O -- RW Character string (Axis address of
#1013)
M_SSEC_MPPOSW_PSW6_DOG1 T_FLOATBIN/T_LONG 6th position switch hypothetical dog O -- RW ±99999.999
position 1
M_SSEC_MPPOSW_PSW6_DOG2 T_FLOATBIN/T_LONG 6th position switch hypothetical dog O -- RW ±99999.999
position 2
M_SSEC_MPPOSW_PSW6_CKTYP T_CHAR 6th position switch PSW check method O -- RW 0,1
switch
M_SSEC_MPPOSW_PSW7_PAXNAM T_STR 7th position switch axis name O -- RW Character string (Axis address of
#1013)
M_SSEC_MPPOSW_PSW7_DOG1 T_FLOATBIN/T_LONG 7th position switch hypothetical dog O -- RW ±99999.999
position 1
M_SSEC_MPPOSW_PSW7_DOG2 T_FLOATBIN/T_LONG 7th position switch hypothetical dog O -- RW ±99999.999
position 2
M_SSEC_MPPOSW_PSW7_CKTYP T_CHAR 7th position switch PSW check method O -- RW 0,1
switch
M_SSEC_MPPOSW_PSW8_PAXNAM T_STR 8th position switch axis name O -- RW Character string (Axis address of
#1013)
M_SSEC_MPPOSW_PSW8_DOG1 T_FLOATBIN/T_LONG 8th position switch hypothetical dog O -- RW ±99999.999
position 1
M_SSEC_MPPOSW_PSW8_DOG2 T_FLOATBIN/T_LONG 8th position switch hypothetical dog O -- RW ±99999.999
position 2
M_SSEC_MPPOSW_PSW8_CKTYP T_CHAR 8th position switch PSW check method O -- RW 0,1
switch
M_SSEC_MPPOSW_PSW_EX_NAME(x) T_STR 9th-24th position switch axis name O -- RW Character string (Axis address of
(x=9-) #1013)
M_SSEC_MPPOSW_PSW_EX_DOG1(x) T_FLOATBIN/T_LONG 9th-24th position switch hypothetical O -- RW ±99999.999
dog position 1 (x=9-)
Program tree
Command Data type Description PS AX RW Range
M_SSEC_TREE_MAIN_DEV T_LONG Name of main device in execution O -- R
M_SSEC_TREE_MAIN_O T_STR Main O No. in execution O -- R
M_SSEC_TREE_MAIN_N T_LONG Main N No. in execution O -- R
M_SSEC_TREE_MAIN_B T_LONG Main B No. in execution O -- R
M_SSEC_TREE_SUB_DEV(x) T_LONG Sub 1 to 10 device name in execution O -- R
(x=1 to 10)
M_SSEC_TREE_SUB_O(x) T_STR Sub 1 to 10 O number in execution O -- R
(x=1 to 10)
M_SSEC_TREE_SUB_N(x) T_LONG Sub 1 to 10 N number in execution O -- R
(x=1 to 10)
M_SSEC_TREE_SUB_B(x) T_LONG Sub 1 to 10 B number in execution O -- R
(x=1 to 10)
M_SSEC_TREE_SUB_L(x) T_LONG Sub 1 to 10 number of times of O -- R
repetition (x=1 to 10)
M_SSEC_TREE_PROG_LIST T_BUFF Program tree information in execution O -- R
(ONB) displayed program name
M_SSEC_TREE_PROG_LIST2 T_BUFF Program tree information in execution O -- R
(ONB) internal program name
M_SSEC_TREE_PROG_LIST_PATH(x) T_STR Program path information (X=1 to 2) O -- R
*Prohibited to be used from HMI
Sampling parameter
Command Data type Description PS AX RW Range
M_SSEC_SMP_PRM_TRIGGER T_SHORT Sampling trigger -- -- RW 0,1,9
M_SSEC_SMP_PRM_SAMP_RATE T_SHORT Sampling cycle -- -- RW 0x01 to 0xFF
M_SSEC_SMP_PRM_SAMP_NOS T_SHORT The number of pieces of sampling data -- -- RW 0 to 8
M_SSEC_SMP_PRM_BUFF_ADDR T_LONG Sampling data buffer address -- -- RW 0 to Address
M_SSEC_SMP_PRM_BUFF_SIZE T_LONG Sampling data buffer size -- -- RW 0 to Size
M_SSEC_SMP_PRM_SAMP_ADDR1 T_LONG Sampling address #1 (Compatible with -- -- RW 0 to Address
M625)
M_SSEC_SMP_PRM_SAMP_ADDR2 T_LONG Sampling address #2 (Compatible with -- -- RW 0 to Address
M625)
M_SSEC_SMP_PRM_SAMP_ADDR3 T_LONG Sampling address #3 (Compatible with -- -- RW 0 to Address
M625)
M_SSEC_SMP_PRM_SAMP_ADDR4 T_LONG Sampling address #4 (Compatible with -- -- RW 0 to Address
M625)
M_SSEC_SMP_PRM_SAMP_ADDR5 T_LONG Sampling address #5 (Compatible with -- -- RW 0 to Address
M625)
M_SSEC_SMP_PRM_SAMP_ADDR6 T_LONG Sampling address #6 (Compatible with -- -- RW 0 to Address
M625)
M_SSEC_SMP_PRM_SAMP_ADDR7 T_LONG Sampling address #7 (Compatible with -- -- RW 0 to Address
M625)
M_SSEC_SMP_PRM_SAMP_ADDR8 T_LONG Sampling address #8 (Compatible with -- -- RW 0 to Address
M625)
M_SSEC_SMP_PRM_SAMP_EX_ADDR1 T_LONG Sampling address #1 -- -- RW 0 to Address or Symbol (Within 16
letters)
M_SSEC_SMP_PRM_SAMP_EX_ADDR2 T_LONG Sampling address #2 -- -- RW 0 to Address or Symbol (Within 16
letters)
M_SSEC_SMP_PRM_SAMP_EX_ADDR3 T_LONG Sampling address #3 -- -- RW 0 to Address or Symbol (Within 16
letters)
M_SSEC_SMP_PRM_SAMP_EX_ADDR4 T_LONG Sampling address #4 -- -- RW 0 to Address or Symbol (Within 16
letters)
M_SSEC_SMP_PRM_SAMP_EX_ADDR5 T_LONG Sampling address #5 -- -- RW 0 to Address or Symbol (Within 16
letters)
M_SSEC_SMP_PRM_SAMP_EX_ADDR6 T_LONG Sampling address #6 -- -- RW 0 to Address or Symbol (Within 16
letters)
Servo monitor
Command Data type Description PS AX RW Range
M_SSEC_MSV_GAIN T_LONG Gain -- O R
M_SSEC_MSV_DROOP T_LONG Droop -- O R
M_SSEC_MSV_REV_SPD T_SHORT Rotation speed -- O R
M_SSEC_MSV_MAX_CUR1 T_SHORT MAX current 1 -- O R
M_SSEC_MSV_MAX_CUR2 T_SHORT MAX current 2 -- O R
M_SSEC_MSV_OVER_LOAD T_SHORT Overload -- O R
M_SSEC_MSV_OVER_REG T_SHORT Regenerative load -- O R
M_SSEC_MSV_AMP_DISP T_CHAR Drive unit display -- O R
M_SSEC_MSV_ALARM1 T_STR Alarm 1 -- O R
M_SSEC_MSV_ALARM2 T_STR Alarm 2 -- O R
M_SSEC_MSV_ALARM3 T_STR Alarm 3 -- O R
M_SSEC_MSV_ALARM4 T_STR Alarm 4 -- O R
M_SSEC_MSV_CYC_CNT T_LONG Cycle counter -- O R
M_SSEC_MSV_GRDSP T_FLOATBIN/T_LONG Grid interval -- O R
M_SSEC_MSV_GRID T_FLOATBIN/T_LONG Grid amount -- O R
M_SSEC_MSV_MAC_POS T_FLOATBIN/T_LONG Machine position -- O R
M_SSEC_MSV_MOT_POS T_FLOATBIN/T_LONG Motor end FB -- O R
M_SSEC_MSV_SCA_POS T_FLOATBIN/T_LONG Machine end FB -- O R
M_SSEC_MSV_FB_ERROR T_LONG FB error -- O R
M_SSEC_MSV_DFB_COMP T_LONG DFB compensation amount -- O R
M_SSEC_MSV_DISTANCE T_FLOATBIN/T_LONG Remaining command -- O R
M_SSEC_MSV_POSITION2 T_FLOATBIN/T_LONG Current value (2) -- O R
M_SSEC_MSV_MANUAL_IT T_FLOATBIN/T_LONG Manual interruption amount -- O R
M_SSEC_MSV_ABS_SYS T_STR Detection system -- O R
M_SSEC_MSV_ABS_PON_POS T_FLOATBIN/T_LONG Power ON position -- O R
M_SSEC_MSV_ABS_POF_POS T_FLOATBIN/T_LONG Power OFF position -- O R
M_SSEC_MSV_ABS_MAC_POS T_FLOATBIN/T_LONG Current position -- O R
M_SSEC_MSV_R0 T_SHORT R0 (Revolution counter in setting -- O R
reference position)
M_SSEC_MSV_P0 T_LONG P0 (Position within one revolution in -- O R
setting reference position)
Servo parameter
Command Data type Description PS AX RW Range
M_SSEC_MPSV_SV001 T_SHORT SV01: Motor side gear ratio -- O RW -32768 to 32767
M_SSEC_MPSV_SV002 T_SHORT SV02: Machine side gear ratio -- O RW -32768 to 32767
M_SSEC_MPSV_SV003 T_SHORT SV03: Position loop gain 1 -- O RW -32768 to 32767
M_SSEC_MPSV_SV004 T_SHORT SV04: Position loop gain 2 -- O RW -32768 to 32767
M_SSEC_MPSV_SV005 T_SHORT SV05: Speed loop gain 1 -- O RW -32768 to 32767
M_SSEC_MPSV_SV006 T_SHORT SV06: Speed loop gain 2 -- O RW -32768 to 32767
M_SSEC_MPSV_SV007 T_SHORT SV07: Speed loop delay compensation -- O RW -32768 to 32767
M_SSEC_MPSV_SV008 T_SHORT SV08: Speed loop lead compensation -- O RW -32768 to 32767
M_SSEC_MPSV_SV009 T_SHORT SV09: Current loop q axis lead -- O RW -32768 to 32767
compensation
M_SSEC_MPSV_SV010 T_SHORT SV10: Current loop d axis lead -- O RW -32768 to 32767
compensation
M_SSEC_MPSV_SV011 T_SHORT SV11: Current loop q axis gain -- O RW -32768 to 32767
M_SSEC_MPSV_SV012 T_SHORT SV12: Current loop d axis gain -- O RW -32768 to 32767
M_SSEC_MPSV_SV013 T_SHORT SV13: Current limit value 1 -- O RW -32768 to 32767
M_SSEC_MPSV_SV014 T_SHORT SV14: Current limit value 2 -- O RW -32768 to 32767
M_SSEC_MPSV_SV015 T_SHORT SV15: Acceleration rate feed forward -- O RW -32768 to 32767
gain
M_SSEC_MPSV_SV016 T_SHORT SV16: Lost motion compensation gain -- O RW -32768 to 32767
1
M_SSEC_MPSV_SV017 T_SHORT SV17: Servo system specification -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSV_SV018 T_SHORT SV18: Ball screw pitch -- O RW -32768 to 32767
M_SSEC_MPSV_SV019 T_SHORT SV19: Position detector resolution -- O RW 0 to 65535
M_SSEC_MPSV_SV020 T_SHORT SV20: Speed detector resolution -- O RW -32768 to 32767
M_SSEC_MPSV_SV021 T_SHORT SV21: Overload detection time -- O RW -32768 to 32767
constant
M_SSEC_MPSV_SV022 T_SHORT SV22: Overload detection time level -- O RW -32768 to 32767
M_SSEC_MPSV_SV023 T_SHORT SV23: Excessive error value 1 -- O RW -32768 to 32767
M_SSEC_MPSV_SV024 T_SHORT SV24: In-position width -- O RW -32768 to 32767
M_SSEC_MPSV_SV025 T_SHORT SV25: Motor type -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSV_SV026 T_SHORT SV26: Excessive error value 2 (During -- O RW -32768 to 32767
servo OFF)
M_SSEC_MPSV_SV027 T_SHORT SV27: Servo function 1 -- O RW 0x0000 to 0xFFFF
Software configuration
Command Data type Description PS AX RW Range
M_SSEC_SWCFG_NC_VER T_STR NC system version -- -- R
M_SSEC_SWCFG_PLC_VER T_STR PLC version -- -- R
M_SSEC_SWCFG_PLCE_VER T_STR PLCe version (Extended external alarm -- -- R
message)
M_SSEC_SWCFG_LANG3_VER T_STR 3rd language version -- -- R
M_SSEC_SWCFG_LANG4_VER T_STR 4th language version -- -- R
M_SSEC_SWCFG_SVANP_VER T_STR Servo drive unit version -- O R
M_SSEC_SWCFG_SPAMP_VER T_STR Spindle drive unit version -- O R
M_SSEC_SWCFG_OS_VER T_STR OS version -- -- R
M_SSEC_SWCFG_APLC_VER T_STR APLC version -- -- R
M_SSEC_SWCFG_USER1_VER T_STR USER1 version -- -- R
M_SSEC_SWCFG_NC_EX_VER T_STR NC system version (4 digit display) -- -- R
M_SSEC_SWCFG_HMI_VER T_STR HMI version - - W 31 letters
M_SSEC_SWCFG_LANG_VER(x) T_STR LANGx version (x=1 to 23) - - RW 31 letters
M_SSEC_SWCFG_LADFILE_NOS T_LONG The number of registered ladder files -- -- R 0: No ladder file 1 to 32: The
number of registered ladder files -
1: Error
M_SSEC_SWCFG_LADFILE_NAME(x) T_STR Ladder file name (x=1 to 32) -- -- R 8 letters
M_SSEC_SWCFG_LADFILE_TITLE(x) T_STR Ladder file title (x=1 to 32) -- -- R 32 letters
M_SSEC_SWCFG_LADFILE_EXEC_TYPE(x) T_LONG Execution type (x=1 to 32) -- -- R 0: No registration data 1: High-
speed ladder 2: Middle-speed
ladder 3: Standby ladder 4: Low-
speed ladder 5: No execution
target -1: Error
Speed information
Command Data type Description PS AX RW Range
M_SSEC_SPDINF_FC T_FLOATBIN FC (Combined speed) O -- R
M_SSEC_SPDINF_FA T_FLOATBIN FA: F command feedrate O -- R
M_SSEC_SPDINF_FH T_FLOATBIN FH: Head feedrate O - R
M_SSEC_SPDINF_DISP_FC T_FLOATBIN Speed display FC (Combined speed) O -- R
Spindle information
Command Data type Description PS AX RW Range
M_SSEC_SPINF_REV_SPD T_LONG Spindle rotation speed (rev/min) -- O R 0 to 999999
M_SSEC_SPINF_LOD Spindle load value O R
M_SSEC_SPINF_OPT_SP_NO T_CHAR Spindle No. of optical spindle -- O R 1 to 4
M_SSEC_SPINF_MET_SP_NO T_CHAR Spindle No. of metal spindle -- O R 1 to 4
M_SSEC_SPINF_OPT_SP_NUM T_CHAR The total number of optical spindles -- -- R 0 to 4
M_SSEC_SPINF_MET_SP_NUM T_CHAR The total number of metal spindles -- -- R 0 to 4
Spindle monitor
Command Data type Description PS AX RW Range
M_SSEC_MSP_WORK_TIME T_LONG Operation time -- O RW 0x00 to 0xFF
M_SSEC_MSP_ALM_HIST_TM1 T_LONG Alarm history 1 (Time) -- O RW 0x00 to 0xFF
M_SSEC_MSP_ALM_HIST_TM2 T_LONG Alarm history 2 (Time) -- O RW 0x00 to 0xFF
M_SSEC_MSP_GAIN T_LONG Gain -- O R
M_SSEC_MSP_DROOP T_LONG Droop -- O R
M_SSEC_MSP_REV_SPD T_LONG Rotation speed -- O R
M_SSEC_MSP_LOAD T_LONG Load -- O R
M_SSEC_MSP_AMP_DISP T_CHAR Drive unit display -- O R
M_SSEC_MSP_ALARM1 T_STR Alarm 1 -- O R
M_SSEC_MSP_ALARM2 T_STR Alarm 2 -- O R
M_SSEC_MSP_ALARM3 T_STR Alarm 3 -- O R
M_SSEC_MSP_ALARM4 T_STR Alarm 4 -- O R
M_SSEC_MSP_CYC_CNT T_LONG Cycle counter -- O R
M_SSEC_MSP_CMD1L T_LONG Control input 1L -- O R
M_SSEC_MSP_CMD1H T_LONG Control input 1H -- O R
M_SSEC_MSP_CMD2L T_LONG Control input 2L -- O R
M_SSEC_MSP_CMD2H T_LONG Control input 2H -- O R
M_SSEC_MSP_CMD3L T_LONG Control input 3L -- O R
M_SSEC_MSP_CMD3H T_LONG Control input 3H -- O R
M_SSEC_MSP_CMD4L T_LONG Control input 4L -- O R
M_SSEC_MSP_CMD4H T_LONG Control input 4H -- O R
M_SSEC_MSP_STS1L T_LONG Control output 1L -- O R
M_SSEC_MSP_STS1H T_LONG Control output 1H -- O R
M_SSEC_MSP_STS2L T_LONG Control output 2L -- O R
M_SSEC_MSP_STS2H T_LONG Control output 2H -- O R
M_SSEC_MSP_STS3L T_LONG Control output 3L -- O R
M_SSEC_MSP_STS3H T_LONG Control output 3H -- O R
M_SSEC_MSP_STS4L T_LONG Control output 4L -- O R
M_SSEC_MSP_STS4H T_LONG Control output 4H -- O R
M_SSEC_MSP_UNIT_TYP T_STR Drive unit type -- O R
M_SSEC_MSP_UNIT_NO T_STR Drive unit serial No. -- O R
M_SSEC_MSP_SW_VER T_STR Software version -- O R
Spindle parameter
Command Data type Description PS AX RW Range
M_SSEC_MPSP_SP001 T_SHORT SP001: Magnetic sensor and motor -- O RW -32768 to 32767
built-in encoder orientation-mode
position loop gain
M_SSEC_MPSP_SP002 T_SHORT SP002: Encoder orientation-mode -- O RW -32768 to 32767
position loop gain
M_SSEC_MPSP_SP003 T_SHORT SP003: C-axis non-cutting position loop -- O RW -32768 to 32767
gain
M_SSEC_MPSP_SP004 T_SHORT SP004: Orientation in-position width -- O RW -32768 to 32767
M_SSEC_MPSP_SP005 T_SHORT SP005: Orientation-mode change -- O RW -32768 to 32767
speed limit value
M_SSEC_MPSP_SP006 T_SHORT SP006: Orientation-mode deceleration -- O RW -32768 to 32767
rate
M_SSEC_MPSP_SP007 T_SHORT SP007: Orientation position shift -- O RW -32768 to 32767
amount
M_SSEC_MPSP_SP008 T_SHORT SP008: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP009 T_SHORT SP009: Synchronous tapping position -- O RW -32768 to 32767
loop gain
M_SSEC_MPSP_SP010 T_SHORT SP010: Spindle synchronization position -- O RW -32768 to 32767
loop gain
M_SSEC_MPSP_SP011 T_SHORT SP011: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP012 T_SHORT SP012: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP013 T_SHORT SP013: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP014 T_SHORT SP014: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP015 T_SHORT SP015: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP016 T_SHORT SP016: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP017 T_SHORT SP017: Maximum motor speed -- O RW -32768 to 32767
M_SSEC_MPSP_SP018 T_SHORT SP018: Motor zero speed -- O RW -32768 to 32767
M_SSEC_MPSP_SP019 T_SHORT SP019: Speed command -- O RW -32768 to 32767
acceleration/deceleration time constant
M_SSEC_MPSP_SP020 T_SHORT SP020: Speed detection set value -- O RW -32768 to 32767
M_SSEC_MPSP_SP021 T_SHORT SP021: Torque limit 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP022 T_SHORT SP022: Speed loop gain proportional -- O RW -32768 to 32767
term under speed control
M_SSEC_MPSP_SP023 T_SHORT SP023: Speed loop gain integral term -- O RW -32768 to 32767
under speed control
M_SSEC_MPSP_SP024 T_SHORT SP024: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP025 T_SHORT SP025: Spindle gear teeth count 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP026 T_SHORT SP026: Spindle gear teeth count 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP027 T_SHORT SP027: Spindle gear teeth count 3 -- O RW -32768 to 32767
M_SSEC_MPSP_SP028 T_SHORT SP028: Spindle gear teeth count 4 -- O RW -32768 to 32767
M_SSEC_MPSP_SP029 T_SHORT SP029: Motor shaft gear teeth count 1 -- O RW -32768 to 32767
M_SSEC_MPSP_SP030 T_SHORT SP030: Motor shaft gear teeth count 2 -- O RW -32768 to 32767
M_SSEC_MPSP_SP031 T_SHORT SP031: Motor shaft gear teeth count 3 -- O RW -32768 to 32767
M_SSEC_MPSP_SP032 T_SHORT SP032: Motor shaft gear teeth count 4 -- O RW -32768 to 32767
M_SSEC_MPSP_SP033 T_SHORT SP033: Spindle function 1 -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP034 T_SHORT SP034: Spindle function 2 -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP035 T_SHORT SP035: Spindle function 3 -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP036 T_SHORT SP036: Spindle function 4 -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP037 T_SHORT SP037: Spindle function 5 -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP038 T_SHORT SP038: Spindle function 6 -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP039 T_SHORT SP039: Drive unit type -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP040 T_SHORT SP040: Motor type -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP041 T_SHORT SP041: Regenerative resistor type -- O RW 0x0000 to 0xFFFF
(SPJ)/Power supply type (SP)
M_SSEC_MPSP_SP042 T_SHORT SP042: Detector range for C axis -- O RW -32768 to 32767
M_SSEC_MPSP_SP043 T_SHORT SP043: Detector range for synchronous -- O RW -32768 to 32767
tapping, spindle synchronization
M_SSEC_MPSP_SP044 T_SHORT SP044: NC communication frequency -- O RW -32768 to 32767
M_SSEC_MPSP_SP045 T_SHORT SP045: Not used -- O RW -32768 to 32767
Spindle/Standby
Command Data type Description PS AX RW Range
M_SSEC_SPWAIT_TOOL_NO(x) T_LONG Spindle stand by (Tool No.) (x=0 to 4) O -- RW (To designate part system,
designate magazine)
M_SSEC_SPWAIT_D_NO(x) T_SHORT Spindle stand by (Auxiliary: D) (x=0 to O -- RW (To designate part system,
4) designate magazine)
M_SSEC_SPWAIT_DISP_NOS T_LONG The number of spindles stand by to -- -- R
display
M_SSEC_SPWAIT_SPINDL_TLIFE T_STR Spindle tool's life management data O -- R (To designate part system,
designate magazine)
M_SSEC_SPWAIT_WAIT_TLIFE T_STR Stand by tool's life management data O -- R (To designate part system,
designate magazine)
Symbol (Sub-section)
Command Data type Description PS AX RW Range
M_SSEC_PLCINDXPRM_PSW13DOG2 T_FLOATBIN PSW13 Area setting 2 - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_PSW14DOG1 T_FLOATBIN PSW14 Area setting 1 - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_PSW14DOG2 T_FLOATBIN PSW14 Area setting 2 - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_PSW15DOG1 T_FLOATBIN PSW15 Area setting 1 - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_PSW15DOG2 T_FLOATBIN PSW15 Area setting 2 - O RW -99999.999 to 99999.999
M_SSEC_PLCINDXPRM_PUSHT T_FLOATBIN Stopper amount - O RW 0 to 359.999
M_SSEC_PLCINDXPRM_PUSHT1 T_SHORT Stopper standby time - O RW 0 to 9999
M_SSEC_PLCINDXPRM_PUSHT2 T_SHORT Stopper torque release time - O RW 0 to 9999
M_SSEC_PLCINDXPRM_PUSHT3 T_SHORT Set position signal output delay time - O RW 0 to 9999
M_SSEC_TOFS2S_WEAR_L(x) T_FLOATBIN/T_LONG Wear in length (x=1 to 999) O -- RW ±99999.999
M_SSEC_TOFS2S_WEAR_R(x) T_FLOATBIN/T_LONG Wear in diameter (x=1 to 999) O -- RW ±999.999
M_SSEC_PLCINDXPRM_TL2 T_SHORT Operation parameter group 2 Torque - O RW 0 to 500
limit value
M_SSEC_PLCINDXPRM_OD2 T_SHORT Operation parameter group 2 Excessive - O RW 0 to 32767
error detection width
M_SSEC_PLCINDXPRM_JUST2 T_FLOATBIN Operation parameter group 2 Set - O RW 0 to 99999.999
position output width
M_SSEC_PLCINDXPRM_NEAR2 T_FLOATBIN Operation parameter group 2 Near set - O RW 0 to 99999.999
position output width
M_SSEC_PLCINDXPRM_SMGST2 T_SHORT Operation parameter group 2 - O RW 0x01,0x0F
Acceleration/deceleration type
M_SSEC_PLCINDXPRM_ASPEED3 T_LONG Operation parameter group 3 - O RW 1 to 100000
Automatic operation speed
M_SSEC_PLCINDXPRM_MSPEED3 T_LONG Operation parameter group 3 Manual - O RW 1 to 100000
operation speed
M_SSEC_PLCINDXPRM_TIMEL3_1 T_SHORT Operation parameter group 3 - O RW 1 to 9999
Acceleration/deceleration time constant
1
M_SSEC_PLCINDXPRM_TIMEL3_2 T_SHORT Operation parameter group 3 - O RW 1 to 999
Acceleration/deceleration time constant
2
M_SSEC_PLCINDXPRM_TL3 T_SHORT Operation parameter group 3 Torque - O RW 0 to 500
limit value
M_SSEC_MPSP_SP142 T_SHORT SP142: 2nd speed loop gain delay lead -- O RW -32768 to 32767
item during C axis cutting
M_SSEC_MPSP_SP143 T_SHORT SP143: 3rd speed loop gain -- O RW -32768 to 32767
proportional item during C axis cutting
M_SSEC_MPSP_SP144 T_SHORT SP144: 3rd speed loop gain integral -- O RW -32768 to 32767
item during C axis cutting
M_SSEC_MPSP_SP145 T_SHORT SP145: 3rd speed loop gain delay lead -- O RW -32768 to 32767
item during C axis cutting
M_SSEC_MPSP_SP146 T_SHORT SP146: Speed loop gain proportional -- O RW -32768 to 32767
item for stop during C axis cutting
M_SSEC_MPSP_SP147 T_SHORT SP147: Speed loop gain integral item -- O RW -32768 to 32767
for stop during C axis cutting
M_SSEC_MPSP_SP148 T_SHORT SP148: Speed loop gain delay lead item -- O RW -32768 to 32767
for stop during C axis cutting
M_SSEC_MPSP_SP149 T_SHORT SP149: C axis reference position speed -- O RW -32768 to 32767
M_SSEC_MPSP_SP150 T_SHORT SP150: C axis reference position -- O RW -32768 to 32767
deceleration point
M_SSEC_MPSP_SP151 T_SHORT SP151: C axis reference position return -- O RW 0x0000 to 0xFFFF
shift amount (low byte)
M_SSEC_MPSP_SP152 T_SHORT SP152: C axis reference position return -- O RW 0x0000 to 0xFFFF
shift amount (high byte)
M_SSEC_MPSP_SP153 T_SHORT SP153: C axis in-position width -- O RW 0x0000 to 0xFFFF
M_SSEC_MPSP_SP154 T_SHORT SP154: Excessive error width on C axis -- O RW 0x0000 to 0xFFFF
(low byte)
M_SSEC_MPSP_SP155 T_SHORT SP155: Excessive error width on C axis -- O RW 0x0000 to 0xFFFF
(high byte)
M_SSEC_MPSP_SP156 T_SHORT SP156: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP157 T_SHORT SP157: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP158 T_SHORT SP158: Not used -- O RW -32768 to 32767
M_SSEC_MPSP_SP159 T_SHORT SP159: Variable excitation ratio during -- O RW -32768 to 32767
C axis not cutting
M_SSEC_MPSP_SP160 T_SHORT SP160: Variable excitation ratio during -- O RW -32768 to 32767
C axis not cutting
M_SSEC_MPSP_SP161 T_SHORT SP161: Current loop gain magnification -- O RW -32768 to 32767
1 during C axis not cutting
M_SSEC_MPSP_SP162 T_SHORT SP162: Current loop gain magnification -- O RW -32768 to 32767
2 during C axis not cutting
Tool measurement
Command Data type Description PS AX RW Range
M_SSEC_TLM_SW T_LONG TLM switch O -- R
M_SSEC_TLM_LAST_MOVE_DIRECTION T_CHAR Last travel direction O O R 0: Positive, 1: Negative
M_SSEC_TLM_LAST_MOVE_AXIS T_CHAR Last travel axis O -- R 0: No travel, 1 to 8: Axis number
which moved
M_SSEC_TLM_SECOND_SKIP T_SHORT 2nd skip contact O -- R 0: EMG status, 1: Stoppd state
M_SSEC_TLM_RST_INPUT_STS T_CHAR Reset input status O -- RW 0: Reset is not input (OFF) 1:
Reset is input (OFF-->ON)
M_SSEC_TLM_SKP_POS_READ_STS T_CHAR Skip position read status O -- RW 0: Skip position is not read yet 1:
Skip position is read
M_SSEC_TLM_TLMS_SW T_LONG TLMS status (L sys tool measure 2) O -- R 0,1
M_SSEC_TLM_L2_STS T_LONG Tool compensation amount measure O -- RW Setting is only 0
status (L sys tool measure 2)
M_SSEC_TLM_EXTWOFS_STS T_LONG External workpiece coordinate offset O -- RW Setting is only 0
measure status (L sys tool measure 2)
M_SSEC_TLM_L2_START T_LONG Tool compensation amount measure O -- RW 0, 1
request (L sys tool measure 2)
M_SSEC_TLM_EXTWOFS_START T_LONG External workpiece coordinate offset O -- RW 0, 1
measure request (L sys tool measure 2)
Tool registration
Command Data type Description PS AX RW Range
M_SSEC_TOLREG_POT_NO(x) T_LONG Tool registration data (Pot No.) (x=1 to O -- R
360)
M_SSEC_TOLREG_TOOL_NO(x) T_LONG Tool registration data (Tool No.) (x=1 to O -- RW 0 to 99999999/0 to 9999
360)
M_SSEC_TOLREG_D_NO(x) T_SHORT Tool registration data (Auxiliary: D) (x=1 O -- RW 0 to 99
to 360)