Download as pdf
Download as pdf
You are on page 1of 5
Transformer Oil Testing Laboratory TRANSFORMERS & RECTIFIERS (I) LTD. Survey No.427°/3-4 & 431P/1-2,0pp. Nova petrochemical, | Sarkhe} Bavala Highway, Post: Moraiya, Tal. Senand, Dist. Anmedabad 382 210 | Contact: +912717661694, mww.transformerindia.com Document no. TOTL/F&F/016/1 TEST REPORT Test Report Number & Date TOTL/TER-00760/2018 Date: 29/08/2018 | Name & Address of the customer ~ Moraiya Test lab For,M/s.UPPTCL - Transformer Serial N PC0101395 — a T Make ~ Transformers & Rectifiers (India) Ltd. - ' Particulars of Sample tested Transformer Oil - Condition of Sample on Receipt Good 7 I (a) Method of sampling (a) TOTL/ QSP /17 - _ (0) Location of sampling (b) BOTTOM Number of Sampie/s Tested 2 ~ — Date(s) of Test(s) 28 & 29/08/2018 - to _— | = | Sample Identification 00760 | a i)__Appearance _— _ 2) Density — i 3) Kinematic viscosit v { 4) Flash point oe | Particulars of tests conducted [5) Pour point _ | (Put mark for tests required) 6) Neutralization value - | 7) Interfacial Tension — - 8) Dielectric Dissipation Factor @90 °C 9) Resistivity @90 °C - - 10)Breakdown voltage 11) Water Content — | 42)Oxidation Stability Test a | 13)Presence of Oxidation Inhibitor - 14)Corrosive Sulfur ‘10 | Tests in accordance with Standard /Specification | 15:1866:2000 Table-1 — | | _ —_— a aaa ii Client's requirement Nil 12 | Name of the witnessing persons Nil ee ' Witnessed by Authorized Signatory | VIKAS GUPTA (Ritesh Patel) | £6, ETD-II Sr.Manager-Testing | UPPTCL, GHAZIABAD [Document Name: Test Report Document No: TOTL/FBF/OI6/1 Page no.1/ 5 | Revision No: 02 - Issue No: 07 Issued & Reviewed By: | Date of Revision: 02.03.2017 Issue Date: 01.04.2014 ‘Approved By: j “Transformer Oil Testing Laboratory TRANSFORMERS & RECTIFIERS (I) LTD. — Survey No.4278/3-4 & 431P/1-2,Opp. Nova petrochemical, | Sarkne} Bavala vighway, Post: Moriya, Ta. Sanand, Dist. Anmecabad 362 230 | c ‘Contact: +812717661694, was transformerindia.com ~ Document no. TOTL/F&F/016/1 | TEST REPORT | [Capacity a 160 HVA Test Report No. TTOTL/TBR-00760/2018 | Voltage (HV/LV) 220/132/11 kV Test Requested By Mr. Yagnesh Patel Temperature (°C) 266°C Year of Manufacturer 218 | Frequency (Hz) 50.0Hz —_ Date of sample taken 27 & 28/08/2018 Relative Humidity (%) 42% ~~) | Sample tested on 28 & 29/08/2018 Oil parameters for before impulse test | S.No. | Type of Test | Specification | Results | 1 Water Content 10ppm (Max) ——~—=«*S 4B ppm { | ‘2. Breakdown Voltage 60 kV (Min) i Individual | Value: (78.4,77.8,78.9 ,81.4,82.4,83.8)kV _ 1|3 Density (g/ml) 0.890 g/ml (Max) 0.8275 g/ml i | = - - | [4 Flash Point (°C) (Min) 140°C 143°C S_ Dielectric Dissipation factor (Max) oor T (6 "Resistivity @ 90°C (Min) 6 x 10” ohm-cm [7 “Kinematic Viscosity @ 27°C (Max) | 27 cSt ‘Document Name: Test Report Page no.2/5 (Revision Wo: 02 ~ | Tesue Wo: oF Tesued & Reviewed 8y: GM (Bate of Revision: 02.01.2017 ~ [teste Date: 07.04 2018 Approved By: ~ ‘Transformer Oil Testing Laborato ~ "TRANSFORMERS & RECTIFIERS (I) LTD. B | Survey No.427P/3-4 & 431P/1-2,Opp. Nova petrochemical, ee | Sarkhe; Bavala Highway, Post: Moreiye, Tal. Sanand, Dist. Ahmedabad 382 210 | Contact: +912717661694, www.transformerindia.com TEST REPORT [ ‘Capacity 160 MVA’ “Test Re ~ |TOTL/T&R-00760/2018 Voltage (HV/LV) 220/132/11 kV Test Requested By Mr. Yagnesh Patel Temperature (°C) 26.6 °C Year of Manufacturer 2018 Frequency (Hz) 50.0 Hz Date of sample taken 27 & 28/08/2018 Relative Humidity (%) | 42% ‘Sample tested on 28 & 29/08/2018 Oil parameters for after impulse test S.No. | Type of Test Specification | Results 1 Water Content 10 ppm (Max) | i ' ~~ | Breakdown Voltage [60 kV (Min) | Individual | Value: (73.6,72.8,71.9,74.5,78.1,75.4)kV ' ‘Density (g/ml) 0.890 g/ml (Max) iL fo | li4 F int (°C) (Min) 140°C 5 _ Dielectric Dissipation factor (Max) _ — — | oo a 0.01 0.00068 . 6 “Resistivity @ 90°C (Min) 6x 10 ohm-cm | 250 x 10" ohm-cm | 7 | Kinematic Viscosity @ 27 °C (Max) | 27 cSt ” | | Document No: TOTT/FEF/OTE/? }Pageno.3/5 ‘Issued & Reviewed By: Approved By _ 11 “Transformer Oil Testing Laboratory Survey No.427P/3-4 & 431P/1-2,Opp. Nova petrochemical, Serkhe) Bavala Highway, Post: Moraiya, Tal. Sanand, Dist. Anmedabad 382 210 Contact: 4912717651694, www.transformerindia.com ‘TRANSFORMERS & RECTIFIERS (I) LTD. Document no. TOTL/F&F/016/1 - | Reporting details Test report no.: TOTL/T&R-00760/2018 certieatetio,Fe5034 Document No: TOTL/FBF/OL6/1 Bocument Name: Test Report Page no.4/5 Revision Wo: 02 Tse Wor OF Tosved & Reviewed By: ‘Date of Revision: 02.03.2017 Tosve Date: 01.04.2004 ‘Approves By: | | | | | | | | i ps Test Remarks || | 1) Appearance a | Reference standard 1S 335; 1993 (RA 2005) [Table-1()] | 2 | Density a | Reference Standard 1S 1448 (part 16), 2014 | (Correction as per 1S 335:1993 RA 2005 Table-1 Note-1) | 3° | Kinematic Viscosity @ | Reference Standard AS 1448 (P:25) + 1976 (R 2013) | | “| Interfacial Tension(iery @ | Reference standard TS 6104:197iR 2011 | | | 5 | Pour Point 3 | Reference standard 1S 1448 (FiO): 1970 R 2008 & | Flash Pont @ | Reference Standard 1S 1448 (Pdi) = 2012 | | MOAI wKOH/a | 2 | Reference stendara 15 1448(P:2) 2007 J | [8 [electric Strenats, @ | Reference Standard TS: 67SE1952 R 2008 BDV in kV(rm3) L — B — Brass spherical | Frequency of the test voltage sol | i | Ol temperature, °C eee | Dielectric Dissipation factor | a | Type of test cell used Three terminal eel | j and) |b | Method of measurement —7 ! pt __|___ 18.6262 :1971 R201 ‘Average voltage gradient in the | Sample wile uncer test, in volts(rms)per 250 | | 4 | Frequency of epplied voltage soz | | Temperature & Humidity of the laboratory WCE, <50% {| | during test | 10" [Specie Resistance Type of cell used Three terminal a (ig4) | | Resistivity) Ohm-em, | Method of measurement 15 6103 : 1971 R 2001 | © Averege votege oracient in the somple oso while under test in V/mm ‘| Temperature & Humidity of the laboratory 27°C 42, <50% _ | during test = — Ty | Presence of Oxidation @ | Reference standard TS 13631: 1993 R 2008 Section-1 (3) | ahibitor (Qualitative) | _ Reference standard ASTH 1275 12 | Corrosive Sulfur 15 335:1993 R 2005 Annex 8 a 1S 13567:1992 R 2008 23 | water content Refgrence standard Keri Fischer Titration Methos 24 | Oxidation stabity Test—_| ® | Reference: standard 15335 1972 Ra00simexc__| 2 ‘TRANSFORMERS & RECTIFIERS (I) LTD. ‘Survey No.427P/3-4 & 431P/-2,0pp. Nova petrochemical, Sarkhe} Bavala Highway, Post: Moraiya, Tal. Sanand, Dist. Ahmedabad 382 210 | Contact: +912717661694, www.transformerindia.com ‘Transformer Oil Testing Laboratory | Document no. TOTL/F&F/016/1 Test report no. :TOTL/T&R-00760/2018 The test results relate only to the sample(s) tested. ortfeate No. 75081 Publication or reproduction of this test report in any form other than by complete set of the whole report and in the language written is not permitted without the written consent of the oil testing laboratory, Transformers & Rectifiers (India) Ltd. Any correction/eraser invalidates this test report. Any discrepancy in this test report should be brought to our notice within 15 days from the date of issue “Document Nome: Test Report Document No: TOTFAF/OI6/1 Page no.5/5 | Revision Nor 02 Tssue Worf Tesued & Reviewed 8 a Date of Revision: 02.01.2017, [ Issue Date: 01.04.2014 ‘Approved By: “aH

You might also like