ETABS 2016 16.2.

1 License #*16TX9E92A8JPGJ2

Story Response - Maximum Story Drifts


Summary Description
This is story response output for a specified range of stories and a selected load case or load combination.

Input Data

Name StoryResp3

Display Type Max story drifts Story Range All Stories

Load Case FderivaX Top Story Story3

Output Type Not Applicable Bottom Story Base

Plot

Maximum Story Drifts

Story3

Story2

Story1

Base
0 40 80 120 160 200 240 280 320 360 400 E-6

Drift, Unitless

Proyecto muros concreto.EDB Page 1 of 2 15/03/2018


ETABS 2016 16.2.1 License #*16TX9E92A8JPGJ2

Tabulated Plot Coordinates

Story Response Values

Story Elevation Location X-Dir Y-Dir


mm
Story3 7500 Top 0.000366 0.000257
Story2 5000 Top 0.000334 0.000238
Story1 2500 Top 0.00019 0.000138
Base 0 Top 0 0