90
Fuel cell, liquid product
80
Efficiency limit (%)
70
Fuel cell, steam product
60
40
30
0 200 400 600 800 1000
Operating temperature (°C)
Figure 2.4 Maximum H2 fuel cell efficiency at standard pressure, with reference to higher heating
value. The Carnot limit is shown for comparison, with a 50◦ C exhaust temperature.
The graphs in Figure 2.4 show how these values vary with temperature, and how they
compare with the ‘Carnot limit’. Three important points should be noted:
• Although the graph and table would suggest that lower temperatures are better, the
voltage losses discussed in Chapter 3 are nearly always less at higher temperatures. So
in practice fuel cell voltages are usually higher at higher temperatures.
• The waste heat from the higher-temperature cells is more useful than that from lower-
temperature cells.