Price list
Valid from 01.05.2010
Schöck Isokorb® XT
p. 9 - 18
with insulating element thickness D = 120 mm
Schöck Isokorb®
p. 19 - 34
with insulating element thickness D = 80 mm
Schöck Isokorb®
p. 35 - 37
for steel construction
Schöck Novomur® p. 38 - 39
Schöck Tronsole® p. 41 - 51
Schöck Bole® p. 63 - 65
Schöck ComBAR® p. 67 - 68
Service
Design support department – for technical enquiries
Tel.: +49 7223 967-144
Fax: +49 7223 967-470
E-mail: export@schoeck.com
Marketing services – for ordering technical documents, brochures and price lists
Tel.: +49 7223 967-435
Fax: +49 7223 967-454
E-mail: schoeck@schoeck.com
Website
Product information, tender texts,
CAD files and calculation programs
www.schoeck.com
Delivery times
Each product is labelled with a delivery time:
Delivery time A: Immediate delivery ex works or supply depot
Delivery time B*: Approx. 4 - 5 working days
Delivery time C*: Special elements approx. 8 working days
Delivery time D*: On request
* We would like to draw your attention to the fact that these articles are specially manufactured goods and therefore no order cancellations,
exchanges or returns can be accepted.
4
Contents, Service &
Type designation
Service
For designers
• Telephone hotline for advice from design support department
• Schöck STATIKUS trade magazine with current topics in construction and practical reports
• Advice on site from Schöck product engineers and design support department
• Training on Schöck products and provision of product designs and sales documentation
For everyone
• Information folder with all current product documentation
• Planning CD-ROM with calculation programs, invitation to tender form and CAD files
• Website: www.schoeck.com
5
Contents, Service &
Type designation
General changes:
Balcony slab thickness d changed to h (standard-specific, applies to all types) mm used as the unit of measurement instead of cm (applies to all types)
2nd layer changed to CV50 (standard-specific)
6
Contents, Service &
Type designation
Type designation
with reference to the changeover from the old DIN 1045 to the new DIN 1045-1 (07/2001)
General changes:
Balcony slab thickness d changed to h (standard-specific, applies to all types) mm used as the unit of measurement instead of cm (applies to all types)
2nd layer changed to CV50 (standard-specific)
7
8
Schöck Isokorb® XT d = 120 mm
Isokorb® XT
Application Production type Schöck Isokorb® type
120 mm
Free cantilever balconies/canopies Construction site Page
In-situ concrete balconies KXT 11
Prefabricating plant
Fully prefabricated balconies KXT 11
Element balconies KXT 11
KFXT 12
Special designs Schöck design support department Tel.: +49 7223 967-144
Fax: +49 7223 967-470
E-mail: export@schoeck.com
9
The new Schöck Isokorb® XT
As inventor and innovator in the area of thermal bridges and cantilever construction elements Schöck continuously redefines the state of
Isokorb® XT
120 mm
the art. We therefore adapted the Schöck Isokorb® to the ever increasing demands for thermal insulation and sound protection,
so that it already meets tomorrow's demands today. This means the new Schöck Isokorb® XT will also make a particularly effective
contribution to consistent energy savings and impact sound insulation in the future.
The Schöck Isokorb® XT therefore provides an efficient thermal insulation element with increased impact sound protection.
Optimised pressure
module
Schöck has further developed the
core of the Isokorb® XT, the multi-
patented HTE module. With identical
cross-section and despite the modi-
fied insulating element thickness of
50% thicker insulating 120 mm and an optimised composi-
tion, the module made from high-
element
density micro-fibre reinforced con-
The matching insulating element crete with Kronolith1) guarantees the
thickness contributes not only to high thermal insulation of the Schöck
improved thermal conductivity and Improved insulating
Isokorb® XT. It therefore provides an
increased impact sound protection unsurpassed combination of high
material
but also to a thermal insulation layer load-bearing capacity and optimum The insulating material in the new
which is as uniform and continuous thermal conductivity. Schöck Isokorb® XT consists of
as possible. Neopor®2)
(l = 0.031 W/m·K).
12
0m
m
Approved by
the Passive House
Institute4)
Thanks to its 30% extra thermal insu-
50% better impact sound
lation5) even passive houses can be insulation3)
constructed with free cantilever bal- The Schöck Isokorb® XT significantly
conies without a problem. The new reduces the transfer of impact sound
Schöck Isokorb® XT is approved as a from covered balconies and balconies
"minimal thermal bridge design". into the building. In addition, in
many cases further measures such as
floating flooring are unnecessary.
1)
Kronolith is a registered brand of the Kronos ecochem company
2)
Neopor® is a registered brand of BASF
3)
Compared with the corresponding Schöck Isokorb® types with d = 80 mm and a height of 180 mm with regard to ΔLn,v,w
Further information is available at www.schoeck.de/de/bauphysikvergleich
4)
Passive House Institute, Darmstadt, www.passiv.de
5)
On average for types KXT and QXT compared with the corresponding Schöck Isokorb® types K and Q with d = 80 mm with regard to equivalent Req
10
Schöck Isokorb® type KXT Product group 39
Schöck Isokorb® type KXT: Load-bearing thermal insulation element for free cantilevered balconies. The element transfers bending moments
Isokorb® XT
120 mm
and shear forces.
11
Schöck Isokorb® type KFXT Product group 39
Schöck Isokorb® type KFXT: Load-bearing thermal insulation element for free cantilevered balconies. The element transfers bending
Isokorb® XT
120 mm
moments and shear forces. The two-part version has been developed for the special requirements relating to prefabricating plants.
For rapid installation and easy transport to the construction site.
Please note:
Each basic type is allocated a colour for clear allocation of the upper and lower parts and for
easy differentiation between the types. (Upper and lower part):
Schöck Isokorb® type KFXT 20 green
Schöck Isokorb® type KFXT 30 blue
Schöck Isokorb® type KFXT 40 red
Schöck Isokorb® type KFXT 50 purple
Schöck Isokorb® type KFXT 70 orange
12
Schöck Isokorb® type KXT-HV, KXT-BH Product group 39
Schöck Isokorb® type KXT-HV/KXT-BH: Load-bearing thermal insulation element for free cantilevered balconies with height offset to
Isokorb® XT
120 mm
inside floor slabs. The element transfers bending moments and shear forces.
HV = balcony is lower than the floor slabs/BH = balcony is higher than the floor slabs.
KXT50-HV10-CV35
HV
KXT50-HV15-CV35 1.0 160-250 0.686 B 318.80 340.40
KXT50-HV20-CV35
80 ≥ 220
KXT60-HV10-CV35
KXT60-HV15-CV35 1.0 160-250 0.499 B 382.00 403.60
HV 10 100 mm height offset
KXT60-HV20-CV35 HV 15 150 mm height offset
1)
Equivalent thermal resistance in m2· K/W HV 20 200 mm height offset
Application: Height offset
Production: Construction site/Prefabricating plant - Insulation Price in Euros
material thickness: 120 mm
Schöck Isokorb® Length Element Req1)
Delivery Price/item Price/item
Basic type L in m height H in (F0 / H180) time with F90
mm fire
protection
KXT20-BH10-CV35
KXT20-BH15-CV35 1.0 160-250 1.034 B 201.10 222.70
KXT20-BH20-CV35
Schöck Isokorb® type KXT-BH
KXT30-BH10-CV35
KXT30-BH15-CV35 1.0 160-250 0.843 B 243.50 265.10
KXT30-BH20-CV35
Balcony Floor slab
KXT50-BH10-CV35
BH
KXT60-BH10-CV35
KXT60-BH15-CV35 1.0 160-250 0.499 B 382.00 403.60
KXT60-BH20-CV35 BH 10 100 mm height offset
BH 15 150 mm height offset
1)
Equivalent thermal resistance in m2· K/W BH 20 200 mm height offset
Additional versions Price in Euros
Delivery Surcharge per article
time
Concrete cover CV50 (H ≥ 180 mm) B no surcharge
Solutions for limit load levels and component geometries not described here can be manufac-
tured as special designs, provided the construction component geometry allows this.
Price for this on request.
13
Schöck Isokorb® type KXT-WO, KXT-WU Product group 39
Schöck Isokorb® type KXT-WO/KXT-WU: Load-bearing thermal insulation element for free cantilevered balconies with connection to
Isokorb® XT
120 mm
reinforced concrete walls. The element transfers bending moments and shear forces. The reinforcement is anchored in the wall above
(WO) or below (WU).
Balcony
80 ≥ 220
Construction joint
80 ≥ 220
KX_016_KX-WU_S6_LR-FR
Solutions for limit load levels and component geometries not described here can be
manufactured as special designs, provided the construction component geometry allows this.
Price for this on request.
14
Schöck Isokorb® types QXT and QXT+QXT Product group 39
Schöck Isokorb® type QXT: Load-bearing thermal insulation element for balconies supported by columns and loggia slabs. Element for
Isokorb® XT
120 mm
transferring positive shear forces.
QXT60 170
QXT70, QXT80, QXT90 180
Supported balcony
Schöck Isokorb® type QXT+QXT: Load-bearing thermal insulation element for balconies
supported by columns and loggia slabs. Enables transfer of positive and negative shear forces
due to the crossed bearing bars. QXT60 to QXT90
Supported balcony
15
Schöck Isokorb® type QPXT, QPXT+QPXT Product group 39
Schöck Isokorb® type QPXT ( point connection): Load-bearing thermal insulation element for balconies supported by columns and loggia
Isokorb® XT
120 mm
Schöck Isokorb® type QPXT+QPXT (point connection): Load-bearing thermal insulation element for point support of balconies on
columns and loggia slabs. Element for transferring positive and negative shear forces.
QPXT70+QPXT70 210
16
Schöck Isokorb® types QPZXT and HPXT module Product group 39
Schöck Isokorb® type QPZXT (point connection): Load-bearing thermal insulation element for loggia slabs. Supplementary element
Isokorb® XT
120 mm
without pressure bearings for restraint-free transfer of positive shear forces.
QPZXT75 210
Schöck Isokorb® type HPXT module: Load-bearing thermal insulation element for exact point force transfer of horizontal design forces
parallel and/or perpendicular to insulating layer. For extending linear connections (e.g. type KXT, type QXT).
17
18
Schöck Isokorb® d = 80 mm
Application Production type Schöck Isokorb® type
Isokorb®
Prefabricating plant
80 mm
Fully prefabricated balconies K 21
Element balconies K 21
KF 23
Steel balconies with supporting columns Construction site/Steel construction firm QS 33
Special designs Schöck design support department Tel.: +49 7223 967-144
Baden-Baden Fax: +49 7223 967-470
E-mail: export@schoeck.com
19
Schöck Isokorb®
The Schöck Isokorb® with HTE module and an insulating element thickness of 80 mm offers excellent thermal insulation, documented
safety and economic efficiency. It provides good protection against thermal bridges for cantilevered construction elements and significantly
reduces the risk of construction damage and mould formation.
The secret lies in the pressure bearing – the HTE module. Apart from the building physics and structural benefits, the pressure bearing
pad provides real advantages for installation. This is because the Isokorb® with HTE module has no projecting pressure bearing pad which
could interfere while fitting it in the reinforcement. It is therefore very easy to install and enables ideal handling on site.
Isokorb®
80 mm
1)
Neopor® is a registered brand of BASF
2)
Kronolith is a registered brand of the Kronos ecochem company.
20
Schöck Isokorb® type K Product group 37
Schöck Isokorb® type K: Load-bearing thermal insulation element for free cantilevered balconies. The element transfers bending moments
and shear forces.
Application: Free cantilevered balconies
Production: Construction site/Prefabricating plant - Insulation Price in Euros
material thickness: 80 mm
Schöck Isokorb® Length Element Req2) Delivery Price/item Price/item
Basic type L in m height H in (F0 / H180) time with F90
Isokorb®
80 mm
mm fire
protection
K10-CV351) 1.090 99.20 118.90
1.0 160-250 B
K10-CV35-V8 0.897 124.90 144.60
K20-CV351) 0.884 A/B3) 135.00 154.70 Schöck Isokorb® type K
1.0 160-250
K20-CV35-V8 0.784 B 160.70 180.40
K30-CV351) 0.686 A/B3) 162.10 181.80
K30-CV35-V8 1.0 160-250 0.607 187.80 207.50
B Balcony Floor slab
K30-CV35-V10 0.538 196.00 215.70
K40-CV351) 0.645 A/B4) 179.90 199.60
K40-CV35-V8 0.575 205.60 225.30
1.0 160-250
K40-CV35-V10 0.527 B 213.80 233.50
K40-CV35-VV 0.498 222.60 242.30
K50-CV35 1)
0.562 A/B 3)
215.60 235.30
K50-CV35-V8 0.508 241.30 261.00
1.0 160-250
K50-CV35-V10 0.483 B 249.50 269.20
K50-CV35-VV 0.437 258.30 278.00
K60-CV351) 0.395 A/B4) 258.50 278.20
K60-CV35-V8 0.395 284.20 303.90
1.0 160-250
K60-CV35-V10 0.380 B 292.40 312.10
K60-CV35-VV 0.339 301.20 320.90
K70-CV351) 0.375 A/B4) 283.80 303.50
K70-CV35-V8 0.375 309.50 329.20
1.0 160-250
K70-CV35-V10 0.361 B 317.70 337.40
K70-CV35-VV 0.330 326.50 346.20
K80-CV35-V8 0.354 343.40 363.10
K80-CV35-V10 1.0 160-250 0.354 B 351.60 371.30
K80-CV35-VV 0.330 360.40 380.10
K90-CV35-V8 0.338 372.90 392.60
K90-CV35-V10 1.0 160-250 0.338 B 381.10 400.80
K90-CV35-VV 0.316 389.90 409.60
K100-CV35-V8 0.329 405.80 425.50
K100-CV35-V10 1.0 160-250 0.323 B 414.00 433.70
K100-CV35-VV 0.303 422.80 442.50
1)
The lateral force load range V6 contained in the basic type K... is not included in the type designation.
2)
Equivalent thermal resistance in m2·K/W
3)
Delivery time A applies to heights 160/180/200
4)
Delivery time A applies to heights 160/180/200 and with no fire protection
Schöck Isokorb® type K-Eck: Load-bearing thermal insulation element for free cantilevered external balconies. The element transfers shear
forces and bending moments and consists of two partial elements (1st and 2nd layers).
The Schöck Isokorb® type K-Eck consists of two partial elements (1st and 2nd layer).
A Schöck Isokorb® type K-CV50 element is always required in connection with the "2nd layer"
partial element.
Balcony at the outer corner: Minimum balcony slab thickness h = 180 mm
22
Schöck Isokorb® type KF Product group 37
Schöck Isokorb® type KF: Load-bearing thermal insulation element for free cantilevered balconies. The element transfers bending
moments and shear forces The two-part version has been developed for the special requirements relating to prefabricating plants.
For rapid installation and easy transport to the construction site.
Isokorb®
80 mm
Schöck Isokorb® Length Element Req2) Delivery Price/item Price/item
Basic type L in m height H in (F0 / H180) time with F90
mm fire
protection
KF20-CV351) 0.884 A/B4) 135.00 154.70
1.0 160-250
KF20-CV35-V8 0.784 B 160.70 180.40
KF30-CV351) 0.686 A/B3) 162.10 181.80 Schöck Isokorb® type KF
1.0 160-250
KF30-CV35-V8 0.607 B 187.80 207.50
KF40-CV351) 0.645 A/B4) 179.90 199.60
1.0 160-250
KF40-CV35-V8 0.575 B 205.60 225.30 Balcony Floor
slab
KF50-CV351) 0.562 A/B3) 215.60 235.30
1.0 160-250
KF50-CV35-V8 0.508 B 241.30 261.00
KF70-CV351) 0.375 A/B4) 283.80 303.50
1.0 160-250
KF70-CV35-V8 0.375 B 309.50 329.20
1)
The lateral force load range V6 contained in the basic type KF... is not included in the type designation.
2)
Equivalent thermal resistance in m2·K/W
colour coding
3)
Delivery time A applies to heights 160/180/200 on upper part
4)
Delivery time A applies to heights 160/180/200 and with no fire protection ≥ 100
23
Schöck Isokorb® type K-HV, K-BH Product group 37
Schöck Isokorb® type K-HV/type K-BH: Load-bearing thermal insulation element for free cantilevered balconies with height offset to
inside floor slabs. The element transfers bending moments and shear forces.
HV = balcony is lower than the floor slabs/BH = balcony is higher than the floor slabs.
HV
K60-HV10-CV35
1.0 160-250 0.353 B 348.80 368.50
K60-HV15-CV35
80 ≥ 220
1)
Equivalent thermal resistance in m2· K/W
K60-BH10-CV35
1.0 160-250 0.353 B 348.80 368.50
K60-BH15-CV35
80 ≥ 220
1)
Equivalent thermal resistance in m2· K/W
Solutions for limit load levels and component geometries not described here can be
manufactured as special designs, provided the construction component geometry allows this.
Price for this on request.
24
Schöck Isokorb® type K-WO, K-WU Product group 37
Schöck Isokorb® type K-WO/K-WU: Load-bearing thermal insulation element for free cantilevered balconies with connection to reinforced
concrete walls. The element transfers bending moments and shear forces. The reinforcement is anchored in the wall above (WO) or below (WU).
Isokorb®
80 mm
Schöck Isokorb® Length Element Req1) Delivery Price/item Price/item
Basic type L in m height H in (F0 / H180) time with F90
mm fire
protection
K20-WO-CV35 1.0 160-250 0.820 B 183.70 203.40
K30-WO-CV35 1.0 160-250 0.646 B 222.30 242.00
K50-WO-CV35 1.0 160-250 0.512 B 291.10 310.80 Schöck Isokorb® type K-WO
K60-WO-CV35 1.0 160-250 0.353 B 348.80 368.50
1)
Equivalent thermal resistance in m · K/W
2
Balcony
80 ≥ 220
Construction joint
80 ≥ 220
time
Concrete cover CV30
B no surcharge
Concrete cover CV50 (H ≥ 180 mm)
Solutions for limit load levels and component geometries not described here can be
manufactured as special designs, provided the construction component geometry allows this.
Price for this on request.
25
Schöck Isokorb® types Q and Q+Q Product group 14
Schöck Isokorb® type Q (continuous connection): Load-bearing thermal insulation element for balconies supported by columns and
loggia slabs. Element for transferring positive shear forces.
1)
Equivalent thermal resistance in m2· K/W
2)
Due to design restrictions, a larger minimum element height is required for F90 (see table below). Q10 to Q50
3)
Delivery time A applies to heights 160/180/200 and with no fire protection
by columns and loggia slabs. Enables transfer of positive and negative shear forces due to the
crossed bearing bars. Q70 to Q100
Supported
balcony
26
Schöck Isokorb® types QP and QP+QP Product group 14
Schöck Isokorb® type QP (point connection): Load-bearing thermal insulation element for balconies supported by columns and loggia
slabs. Element for transferring positive shear forces.
Isokorb®
Schöck Isokorb® Length Element Req 1)
Delivery Price/item Price/item
80 mm
Basic type L in mm height H in (F0 / H180) time with F90
mm fire
protection
QP10 300 160-250 0.858 A/B3) 53.00 64.70
QP20 400 160-250 0.712 A/B 3)
78.30 90.00
QP30 500 160-250 0.762 B 97.30 109.00 Schöck Isokorb® type QP
point connection
QP40 300 170-2502) 0.666 B 81.90 93.602)
QP50 400 170-2502) 0.615 B 94.00 105.702)
QP60 300 180-2502) 0.502 B 102.60 114.302) Balcony Floor
slab
QP70 400 180-250 2)
0.457 B 134.70 146.40 2)
Schöck Isokorb® type QP+QP (point connection): Load-bearing thermal insulation element for point support of balconies on columns and
loggia slabs. Element for transferring positive and negative shear forces.
Supported
balcony
27
Schöck Isokorb® types QPZ and V Product group 14
Schöck Isokorb® type QPZ (point connection): Load-bearing thermal insulation element for loggia slabs. Supplementary element without
pressure bearings for restraint-free transfer of positive shear forces.
Schöck Isokorb® type V: Load-bearingthermal insulationelement for loggia slabs and balconies supported on
columns. The element is designed for transfer of shear forces.
Supported balcony
28
Schöck Isokorb® types HP module and EQ module Product group 14
Schöck Isokorb® type HP module: Load-bearing thermal insulation element for exact point force transfer of horizontal design forces
parallel and/or perpendicular to insulating layer. For extending linear connections (e.g. type K, type Q, type V).
Isokorb®
HP-B
Schöck Isokorb® Horizontal force or Length Element Delivery Price/item Price/item
80 mm
Basic type insulating layer L in mm height H in time with F90
Parallel Perpendicular mm fire
protection
HP-C
HP-A X 100 160-250 B 20.10 31.80
HP-B X 100 160-250 B 15.40 27.10
HP-C X X 100 160-250 B 28.60 40.30 Schöck Isokorb® type HP module
point extension
Schöck Isokorb® type EQ module: Load-bearing thermal insulation element for exact point force transfer of design forces from the effects
of earthquakes. For extending linear connections (e.g. type K, type Q).
H anchor
29
Schöck Isokorb® types O and F Product group 14
Schöck Isokorb® type O: Load-bearing thermal insulation element for supporting brackets for corbel supports (point connection).
The spacing of individual elements depends on the specific structural conditions. Spaces are insulated on site.
Floor slab
≥ 180
Console
Schöck Isokorb® type F: Load-bearing thermal insulation element for suspended parapets (point connection). The spacing of individual
elements depends on the specific structural conditions. Spaces are insulated on site.
Parapet
≥ 130
Floor slab
≥ 160
30
Schöck Isokorb® type A and D Product group 14
Schöck Isokorb® type A: Load-bearing thermal insulation element between parapets and ceiling (point connection). The spacing of
individual elements depends on the specific structural conditions. Spaces are insulated on site.
Application: Parapets
Production: Construction site/Prefabricating plant - Insulation Price in Euros
material thickness: 60 mm
60/80 mm
Isokorb®
Schöck Isokorb® Length Element height H Delivery time Price/item Price/item
Basic type L in mm in mm with F90
fire
protection
A 350 160-250 A/B1) 83.80 95.50
1)
Delivery time A applies to height 160 and with no fire protection
≥160
Parapets
Floor slab
A_001
Schöck Isokorb® type D: Load-bearing thermal insulation element for continuous slabs. The element transfers positive and negative
bending moments and shear forces along a single axis.
31
Schöck Isokorb® types S and W Product group 14
Schöck Isokorb® type S: Load-bearing thermal insulation element for cantilever beams. The element transfers bending moments and
shear forces.
material thickness: 80 mm
Schöck Isokorb® Element dimensions Delivery time Price/item Price/item
Basic type with F90
Width W in mm Height H in mm fire
protection
S1 125.70 137.40
S2 151.30 163.00
220 400 B
S3 196.50 208.20 Schöck Isokorb® type S
S4 267.70 279.40
Cantilever
beams
outside
Schöck Isokorb® type W: Load-bearing thermal insulation element for high-storey shear walls The element transfers bending moments in
a vertical direction and shear forces in both vertical and horizontal directions.
32
Schöck Isokorb® types KS and QS Product group 15
Schöck Isokorb® type KS: The thermally insulated connection for free cantilevered steel structures. The element for transfer of bending
moments and shear forces consists of a reinforcement cage with integrated insulation layer for installation in the slab edge. The steel
structure is supplied fully pre-cast by the steel fabricator. The construction enables partial compensation of installation tolerances.
Isokorb®
80 mm
material thickness: 80 mm
Schöck Isokorb® Width Element height Delivery time Price/item
Basic type W in mm H in mm
KS141) 165.60
KS14 V10 176.40
180 180/200/220 B
KS202) 252.20
KS20 V12 262.80
Schöck Isokorb® type KS14
1)
The lateral force level V8 contained in the basic type is not included in the type designation.
2)
The lateral force level V10 contained in the basic type is not included in the type designation.
Balcony
Balcony
Steel structure
Reinforced concrete
inner slab
On-site
faceplate
33
Schöck Isokorb® types KSH and QSH Product group 15
Schöck Isokorb® type KSH:The thermally insulated connection for free cantilevered wooden constructions. The element for transfer of
bending moments and shear forces consists of a reinforcement cage with integrated insulation layer for installation in the slab edge
and a plate for securing the wooden construction. The wooden construction permits a high degree of prefabrication by the carpenter.
The construction enables partial compensation of installation tolerances. Due to the high level of prefabrication by the carpenter, the
assembly time for the wooden construction on site is considerably reduced.
Wooden balcony
Schöck Isokorb® type QSH: The thermally insulated connection for wooden structures with supports. The element for transfer of shear
forces consists of a reinforcement cage with integrated insulation layer for installation in the slab edge and a plate for securing the
wooden construction. The wooden construction permits a high degree of prefabrication by the carpenter. The construction enables partial
compensation of installation tolerances. Due to the high level of prefabrication by the carpenter, the assembly time for the wooden
construction on site is considerably reduced.
34
Schöck Isokorb® For steel construction
Penetrating structural members, such as cantilever canopies or crossbars in frame systems have now become a popular construction
principle in modern steel high-rise construction. However, the good thermal conductivity of steel can lead to disastrous side effects
without a thermal break: the formation of thermal bridges and consequent loss of expensive heating energy.
Free cantilever steel structures involve a further serious risk: the inside surface temperature drops significantly due to the increased
outward flow of heat in non-insulated steel members. This can mean that the minimum requirements for preventing damp are not
complied with even when the outside temperature is only -5 °C. The consequences are structural damage such as condensation formation,
mould growth and corrosion.
The RWTH Aachen University in Germany carried out detailed research comparing various application examples for preventing thermal
bridges in steel construction. The results are clear: none of the current solutions met the statutory requirements for thermal protection and
energy conservation with one exception - the Schöck Isokorb® KST. The Schöck Isokorb® type KST was the only thermal break element for
steel construction to meet all the guidelines, thus providing 100% safety for planning, minimising energy costs and preventing structural
damage.
type KST
Isokorb®
The Schöck Isokorb® type KST is available in two load ranges (KST16, KST22). The insulation material thickness is 80 mm. The essential
steel component for transferring the forces in the Isokorb® consists of stainless steel (l = 15 W/m · K). This reduces thermal conductivity to
a minimum.
35
Schöck Isokorb® types KST and QST Product group 38
Schöck Isokorb® type KST: The thermal insulation element for connecting free cantilevered steel components to steel structures.
Consisting of a KST-ZST module and a KST-QST module. The element is for the transfer of bending moments and shear forces and consists
of non-rusting steel with an integrated insulation layer. The steel structures to be joined are supplied fully pre-cast by the steel fabricator.
Due to the high level of prefabrication at the steel construction works, the installation time for the steel structures on the construction site
is considerably reduced. The element is joined by simple screwed connections.
Schöck Isokorb® type KST-QST module: The thermally insulated element for connecting supported steel components to steel structures.
The element is for the transfer of shear forces and normal forces and consists of non-rusting steel with an integrated insulation layer.
Moments can also be absorbed when using several elements which in combination form an inner lever arm. The steel structures to
be joined are supplied fully pre-cast by the steel fabricator. Due to the high level of prefabrication at the steel construction works,
the installation time for the steel structures on the construction site is considerably reduced. The element is joined by simple screwed
connections.
Steel member
Steel structure
On-site
faceplate
Support
36
Schöck Isokorb® types ZST and ZQST Product group 38
Schöck Isokorb® type KST-ZST module: The thermally insulated element for connecting supported steel components to steel structures.
The element is for the transfer of tensile forces and consists of non-rusting steel with an integrated insulation layer. The steel structures
to be joined are supplied fully pre-cast by the steel fabricator. Due to the high level of prefabrication at the steel construction works,
the installation time for the steel structures on the construction site is considerably reduced. The element is joined by simple screwed
connections.
type KST
Isokorb®
Schöck Isokorb®module, type KST-ZST
Steel structure
Steel member
Support Support
Schöck Isokorb® type KST-ZQST module: The thermally insulated element for connecting supported steel structures. The element is
designed for the transfer of shear forces and normal forces and consists of stainless steel with integrated insulation layer. Moments can
also be absorbed when using several elements which in combination form an inner lever arm. Compared to the QST module, the ZQST
module also has an integrated function for fatigue resistance. The steel structures to be joined are supplied fully pre-cast by the steel
fabricator. Due to the high level of prefabrication at the steel construction works, the installation time for the steel structures on the
construction site is considerably reduced. The element is joined by simple screwed connections.
Support
37
Schöck Novomur®
Non-insulated foundations create a significant thermal bridge effect. Effective insulation is essential in order to avoid the effects associated
with this, such as the risk of mould and increased thermal losses. Schöck Novomur® and Schöck Novomur® light display a high level
of thermal insulation combined with high load-bearing capacity. Added to this is the water-repellent property of the elements which
guarantees that practically no moisture can penetrate the thermal insulation elements and the wall base, even during the shell phase
when dampness can be a problem. Altogether this results in very efficient insulation of the thermal bridge in the foundations. Due to the
water-repellent property, a high level of thermal insulation is present from the start – the elements do not need to dry out for years on
end in order to attain the intended level of thermal insulation.
In terms of load-bearing capacity, Schöck Novomur® is designed for use in apartment buildings. Schöck Novomur® light is the ideal
insulation element for single-family houses.
Approved by building
control authorities
For lime-sand brickwork with normal
mortar or thin-bed mortar and for
solid brickwork (acc. to DIN V 105)
with normal mortar.
Powerful insulation
Sure and safe High load-bearing capacity – powerful Very easy to handle
Interlocked joint without insulation. Element length 0.75 m for
mortar. Ensures easy and exact λ = 0.268 W/(m · K) for Schöck Novomur® convenient handling. Based on
installation. and λ = 0.193 W/(m · K) standard masonry grid dimensions.
for Schöck Novomur® light.
38
Schöck Novomur® Product group 31
Schöck Novomur®/Novomur® light: Load-bearing water-repellent thermal insulation elements for avoiding thermal bridges in
foundations.
Schöck Novomur®: High load-bearing capacity, suitable water-repellent acc. to DIN 4108-3
for apartment buildings. Stone strength class 20 Price in Euros
Schöck Novomur® Width Length Height No./ Delivery Price/m Price/item
Type W in L in cm H in cm pallet time
cm
20-11.5 11.5 100 22.13 16.60
20-15 15 80 24.00 18.00
20-17.5 17.5 75 11.3 A/B 27.07 20.30
60
20-20 20 28.67 21.50
20-24 24 50 31.33 23.50 Schöck Novomur®
Novomur®
Schöck Novomur® light: The thermal insulation element for single water-repellent acc. to DIN 4108-3
family houses. Stone strength class 6 Price in Euros
Schöck Novomur® light Width Length Height No./ Delivery Price/m Price/item
Type W in L in cm H in cm pallet time
cm
6-11.5 11.5 100 15.60 11.70
6-15 15 80 17.07 12.80
6-17.5 17.5 75 11.3 A/B 17.87 13.40
60
6-20 20 18.93 14.20
6-24 24 50 20.80 15.60 Schöck Novomur® light
39
40
Schöck Tronsole®
Page
Type AZ
49
Type AZT
Stair landing/wall
Type ZF
50
Type V
Tronsole®
41
Schöck Tronsole®
Tranquillity is a basic need. In an age of rush and noise in particular, people increasingly long for quiet and relaxation. That is why sound
proofing within buildings is no luxury, but more of an urgent necessity. Planners should pay greater attention to this especially when it
comes to staircases in apartment blocks. Because noisy stairs are a frequent or even daily area of conflict. And legal disputes in particular
convey a clear message.
Top quality
Extra stiff recess form PUR elastomer support
also suitable for large depths of Guarantees maximum impact Safe design
concrete sound insulation values even Type approved, tested for sound and
under high loads. fire prevention.
42
Schöck Tronsole® type T Product group 17
Schöck Tronsole® type T: Schöck Tronsole® type T enables simple and cost-effective impact sound insulation of the staircase and landing.
Suitable for numerous stair landing sizes and stair widths, whether in-situ concrete or prefabricated staircases.
The Schöck Tronsole® type T meets the requirements of fire resistance class F90.
For sound bridge insulation between staircase and stair landing Impact sound reduction: ∆Lw* = 12 dB
Price in Euros
Schöck Tronsole® Standard Standard Reinforcement Delivery Price/item
type element element height2) time3)
length1) H in mm
L in m
160, 180, 200 A
T4 1.0 4ø6 85.10
170, 190, 210, 220 B
160, 180, 200 A
T6 1.0 6ø6 99.80
170, 190, 210, 220 B Schöck Tronsole® type T
160, 180, 200 A
T8 1.0 8ø6 114.50
170, 190, 210, 220 B
1)
Non-standard element lengths 0.9 - 2.0 m: Surcharge 2.20 EUR/10 cm or part thereof
2)
Special element heights ≥ 230 mm: Surcharge 5.95 EUR/element
3)
Delivery time B for all non-standard element lengths and heights
Tronsole®
43
Schöck Tronsole® type F and elastomer layer Product group 17
Schöck Tronsole® type F: Maximum impact sound protection for prefabricated staircase supports. Reliable and ready-to-install for
especially easy handling in the prefabricating plant or on site. Reliably protects joint area from collecting dirt.
Schöck Tronsole® type F is classified for fire protection as building material class B 2 acc. to DIN 4102
For sound bridge insulation between prefabricated staircase and Impact sound reduction: ∆Lw* = 28 dB
stair landing Price in Euros
Schöck Tronsole® Element Element Elastomer Delivery Price/item
type length thickness lining time
L in m in mm length in m
F-SST 1.01) 1.0 A 29.10
F-SST 1.0
higher shear 2 × 1.0 C 45.60
loads1)2) 1.0 10
F 1.0 1.0 A 29.10
Schöck Tronsole® type F
F 1.0
2 × 1.0 C 45.60
higher shear loads2)
Impact sound reduction: Lw* = 28 dB
F 1.2 1.2 A 34.70
F 1.2 1.2 10
2 × 1.2 C 54.50
higher shear loads2)
F 1.5 1.5 A 48.40
F 1.5 1.5 10
2 × 1.5 C 73.20
higher shear loads2)
Tronsole®
Schöck elastomer support: Made from top quality PUR. Optimal impact sound insulation effect even under high load.
44
Schöck Tronsole® type R Product group 17
Schöck Tronsole® type R: Schöck Tronsole® type R can be used for subsequent impact sound insulation on straight or spiral staircases
without the risk of sound bridges. Schöck Tronsole® type R consists of insulation matting and insulation strip elements.
Schöck Tronsole® type R is classified for fire protection as building material class B 2 acc. to DIN 4102.
For acoustic separation of stair treads from the staircase for later Impact sound reduction: ∆Lw* = 15 dB
installation or during renovation Price in Euros
Schöck Tronsole® Length Width Width sufficient Delivery Price/m Price/item
type R L in m B in m in mm for 3) time
approx.
Insulation fabric 10 10 16.70 167.00
4 flights
1.5 5 A
approx.
Insulation fabric 35 35 13.47 471.30
14 flights
Insulation strip 31) H: 7.5 cm approx. 2-3 4.54 136.10
30 3 A Schöck Tronsole® type R
Insulation strip 42) H: 8.5 cm flights 4.81 144.40
1)
For stair treads with a thickness of 30 mm
2)
For stair treads with a thickness of 40 mm
3)
For typical staircase (width: 1m, Tread: 28 cm, 7 steps)
Tronsole®
1)
Setting: approx. 3 mm/24 hours (under standard conditions acc. to DIN 50 014-23/50-2)
2)
sufficient for approx. 3 stair treads
Example for material requirements and costs for carrying out impact sound insulation of stairs
with Schöck Tronsole® type R:1)
45
Schöck Tronsole® type QW Product group 17/171
Schöck Tronsole® type QW: Schöck Tronsole® type QW enables impact sound insulated connection of spiral staircases (in-situ concrete or
precast) to staircase walls.
QW-A2-W-LN
Tronsole®
Key:
Type QW - Z - W - L
L: Stair sleeve
LN: Stair sleeve with collar
W: Wall sleeve
WN: Wall sleeve with collar
Z: Hot-dip galvanised profile
A2: A2 stainless steel profile
46
Schöck Tronsole® type QW Product group 17/171
Tronsole®
Stair sleeve (L) Stair sleeve with collar (LN)
Schöck Tronsole® type B: Load-bearing impact sound insulation element for supporting in-situ concrete or prefabricated staircases on
floor slabs. With integrated edge insulation strips. Important supplement to the other Schöck Tronsole products, especially for use with
basement stairs. Schöck Tronsole® type B is classified for fire protection as building material class B 2 acc. to DIN 4102.
For sound bridge insulation between staircase and floor slab Impact sound reduction: ∆Lw* = 20 dB
Price in Euros
Schöck Tronsole® Support area for Thickness Elastomer Delivery Price/item
Type flight of stairs in mm lining length time
Length Width in m
L in m W in
mm
B-SST1) 1.0 A 54.10
B-SST 1) 10
2 × 1.0 C 74.60
higher shear loads2)
1.0 350 Schöck Tronsole® type B
B 100 x 35 1.0 A 54.10
B 100 x 35 15
2 × 1.0 C 74.60 Impact sound reduction: ∆Lw* = 20 dB
higher shear loads2)
B 100 x 60 1.0 A 57.90
B 100 x 60 1.0 600 15
2 × 1.0 C 78.40
higher shear loads2)
B 120 x 35 1.2 A 57.90
B 120 x 35 1.2 350 15
2 × 1.2 C 82.50
higher shear loads2)
Tronsole®
Recommendation: Special lengths can be produced economically and quickly site by combin-
ing the relevant standard types. Any joints between the component parts can be sealed with
adhesive tape (avoidance of noise bridges).
The Schöck Tronsole® type B enables impact sound insulated support of the first stair on the
floor slab. It rounds off the impact sound insulation solutions for staircases.
Schöck elastomer support: Made from top quality PUR. Optimal impact sound insulation effect even under high load.
48
Schöck Tronsole® types AZ and AZT Product group 17
Schöck Tronsole® type AZ: Plastic recess form with snap-on frame for connecting joint sheets. For impact sound insulation of in-situ
concrete stair landing and staircase wall. Schöck Tronsole® type AZ meets the requirements of fire resistance class F90 (with appropriate
in-situ concrete cover).
For impact sound insulation of in-situ concrete stair landing and Impact sound reduction: ∆Lw* = 26 dB
staircase wall Price in Euros
Schöck Tronsole® Internal dimensions Elastomer Delivery Price/item
Type Width 1)
Height1)
Depth bearings time
W in mm H in mm in mm
AZ 1 × lower 67.80
1 × lower
AZ plus2) 79.80
1 × upper
224/241 166/174 136 1 × lower A
AZ-S3) 91.80
2 × side Schöck Tronsole® type AZ
1 × lower
AZ-S plus4) 1 × upper 103.80
2 × side
1)
rear/front
2)
AZ plus: with additional elastomer support at the top
3)
AZ-S: with additional elastomer supports at the sides
4)
AZ-S plus: with additional elastomer supports at the top and sides
Tronsole®
Schöck Tronsole® type AZT: Plastic recess form with snap-on frame for connecting joint sheets. Additionally with ready-to-fit load-
bearing element. Schöck Tronsole® type AZT meets the requirements of fire resistance class F90.
For impact sound insulation of in-situ concrete stair landing and Impact sound reduction: ∆Lw* = 26 dB
staircase wall. Price in Euros
Schöck Tronsole® Internal dimensions Elastomer Delivery Price/item
Type Width1) Height1) Depth bearings time
W in mm H in mm in mm
AZT2) 1 × lower 151.70
224/241 166/174 136 1 × lower A
AZT plus2) 163.70
1 × upper
Load-bearing 224/241 166/174 136 A 83.90
element Schöck Tronsole® type AZT
1)
rear/front
2)
including load-bearing element
49
Schöck Tronsole® types ZF and V Product group 17
Schöck Tronsole® type ZF: Recess form with integrated frame for connecting joint sheets. For use with fully prefabricated landings. Schöck
Tronsole® type ZF meets the requirements of fire resistance class F90 (with appropriate in-situ concrete cover).
For impact sound insulation of in-situ concrete stair landing and Impact sound reduction: ∆Lw* = 26 dB
staircase wall. Price in Euros
Schöck Tronsole® Internal dimensions Elastomer Delivery Price/item
Type Width Height Depth bearings time
W in mm H in mm in mm
ZF 16 160 55.40
ZF 18 250 180 140 1 × lower A 62.30
ZF 20 200 69.10
ZF plus 161) 160 67.40 Schöck Tronsole® type ZF
1 × lower
ZF plus 18 1)
250 180 140 A 74.30
1 × upper
ZF plus 201) 200 81.10
1 × lower
ZF-S 182) 250 180 140 A 86.30
2 × side
1)
ZF plus: with additional elastomer support at the top
2)
ZF-S: with additional elastomer supports at the sides
Tronsole®
Schöck Tronsole® type V: Load-bearing, type approved impact sound insulation element for use between in-situ stair landings and mason-
ry staircase walls. The Schöck Tronsole® type V meets the requirements of fire resistance class F90.
For impact sound insulation of in-situ concrete stair landing and Impact sound reduction: ∆Lw* = 17 dB
staircase wall. Price in Euros
Schöck Tronsole® Length Support Height Reinforcement Delivery Price/item
Type L in mm depth H in mm time
in mm
V 2 N1)
240 2ø6 103.20
V2
V4 365 70 180 4ø6 A 130.50
V6 490 6ø6 158.00
V9 740 9ø6 199.00 Schöck Tronsole® type V
1)
for lifting forces
50
Schöck Tronsole® Joint slabs Product group 17/171
Schöck joint slabs: Impact sound protection measures are only effective when no sound bridges are present. The Schöck joint slabs keep
all joints between the staircase wall and the stairs free from dirt. Schöck joint slabs are classified for fire protection as building material
class B 2 acc. to DIN 4102
Tronsole®
Accessories Price in Euros
Quantity Price/item Schöck joint slab type PL
Adhesive tape 2)
Roll 12.5 m 9.50
Dispersion adhesive Metylan Ovalit S 3)
Bucket 19 kg On request
2)
f or sealing of joints
3)
Adhesive for pre-gluing of Schallschutztreppen®(noise insulated staircase) types (Schöck joint slab type L-SST and
type P-SST, Schöck Tronsole® type F-SST 1.0, Schöck Tronsole® type B-SST 100 x 35) on the prefabricated staircase
elements either on-site or in the prefabricating plant. We recommend applying the adhesive with a large
adhesive spreader (approx. 8 mm) over the entire precast element surfaces.
The Schöck joint slabs prevent sound bridges across joints. For maximum impact sound
insulation, Schöck Tronsoles must be used in conjunction with Schöck joint sheets. The
adhesive tape supplied with the sound proofing package makes it easy to install the stairs Schöck sound proofing package
without any sound bridges, based on the installation instructions.
51
52
Schöck Dowel Systems
Complex structural components such as consoles and friction bearings for force transfer around expansion joints are no longer required. The
Schöck dowel SLD plus gives you greater freedom for design and fitting out. It is approved by the German Institute for Construction Technology
(DIBt) Berlin according to the new DIN 1045-1 standard and can be supplied with optional fire protection collar. A further plus: the constant
high load-bearing capacity up to 40 mm joint opening guarantees a high degree of installation safety. For everyone who hasn't had the chance
so far: compare the options. You will be impressed by the Schöck dowel SLD plus.
Dowel systems
53
Schöck dowel systems SLD plus Product group 28
The prefabricated heavy duty dowel system for joints, incl. dowel
and sleeve Price in Euros
Schöck dowel Weight Delivery time Price/item
Type1) in kg
SLD 40 plus 4.2 75.30
A
SLD Q 40 plus 3.6 105.00
SLD 50 plus 88.70
4.6 A
SLD Q 50 plus 116.50
SLD 60 plus 4.5 103.50 Schöck SLD plus
A
SLD Q 60 plus 5.7 133.00
SLD 70 plus 5.7 128.20
A
SLD Q 70 plus 7.5 173.00
SLD 80 plus 8.5 154.50
A
SLD Q 80 plus 11.5 238.50
SLD 120 plus 13.3 304.50
C
SLD Q 120 plus 17.9 396.40
SLD 150 plus 21.1 414.40
C Schöck SLD Q plus
SLD Q 150 plus 28.2 480.30
(movable in longitudinal and
1)
T he SLD plus dowel system consists of a dowel element and a sleeve element. transverse directions)
The SLD Q plus dowel system consists of a dowel element and a Q sleeve element.
The Q sleeve element allows lateral movement of the dowel by ± 15 mm.
Dowel systems
54
Individual components for SLD plus Product group 28
Dowel systems
Sleeve (movable in longitudinal and transverse directions)
Price in Euros
Individual components
Weight Delivery time Price/item
in kg
SLD Q 40 plus (sleeve1)) 2.0 A 60.00
SLD Q 50 plus (sleeve ) 1)
2.6 A 63.30
SLD Q 60 plus (sleeve1)) 2.9 A 68.20
SLD Q 70 plus (sleeve1)) 3.9 A 92.00
Schöck SLD Q plus sleeve element
SLD Q 80 plus (sleeve ) 1)
6.3 A 135.80
SLD Q 120 plus 9.4 C 192.40
(sleeve1))
SLD Q 150 plus 14.9 C 202.70
(sleeve1))
1)
The SLD Q plus sleeve element allows lateral movement of the dowel by ±15 mm.
55
Schöck Fire protection collars Product group 281
20 10.70
SLD 150 plus
30 11.70
A
20 12.70
SLD Q 150 plus
30 15.00
Fire protection collar with F90 expert advice from iBMB, Braunschweig Technical University
56
Schöck Dowel Systems
High demands are placed on the transfer of shear forces in expansion joints, often requiring complicated joint structures. The ESD from
Schöck provides a connecting element which is safe sophisticated and simple. The compact design of this single shear dowel system is also
suitable for use with relatively small component widths. The element is easy to install and is available in various material grades, making
it suitable for a very wide range of applications. Schöck ESD is supplied in the following designs: with stainless steel sleeve (ESD-S), with
plastic sleeve (ESD-K), coated on one side (ESD-B) or with a flexible stainless steel sleeve which enables transverse movement (ESD-SQ).
Special solutions in terms of dowel material, dowel length and sleeve length can be supplied at short notice to suit your requirements. The
Schöck ESD provides a cost-effective solution for connecting construction components. In combination with the fire protection collar, fulfils
fire resistance class F90.
Combination Combination
sleeve K sleeve S
Attachment Attachment
Dowel systems
plate plate Sleeve SQ
ED ED
St52 galvanised Stainless steel A4
material 1.4571, ESD-B with plastic coating
1.4404, 1.4362 or St52 galvanised or stainless steel A4
1.4462 material 1.4571, 1.4404, 1.4362
or 1.4462
57
Schöck Dowel systems ESD in stainless steel Product group 23
1)
Special lengths on request; stainless steel A made from material 1.4571, 1.4362, 1.4404 or 1.4462
58
Schöck Individual components for ESD Product group 23
Schöck single dowel ED galvanised with plastic coating (B) Price in Euros
Dowel systems
Dowel material Diameter Length Delivery Price/item
in mm L in mm1) time
St52
ESD-B 20 20 300 A 6.10
galvanised
St52
ESD-B 22 22 300 A 7.60
galvanised
St52
ESD-B 25 25 300 A 11.30
galvanised
Schöck ESD-B
St52
ESD-B 30 30 350 A 17.00
galvanised
1)
Special lengths on request
Schöck combination sleeve S in stainless steel A2 for dowel type ED Price in Euros
Dowel material Diameter Length Delivery Price/item
in mm L in mm1) time
Stainless
Sleeve S 20 20 300 A 12.80
steel A2
Stainless
Sleeve S 22 22 300 A 14.30
steel A2
Stainless
Sleeve S 25 25 300 A 17.10
steel A2
Schöck combination sleeve in
Stainless stainless steel
Sleeve S 30 30 350 A 22.50
steel A2
1)
Special lengths on request
59
Schöck Individual components for ESD Product group 23
60
Schöck Fire protection collars Product group 23
Dowel systems
30 10.20
Fire protection collar with F90 expert advice from iBMB, Braunschweig Technical University
61
62
Schöck Bole®
The Schöck Bole® punching shear reinforcement approved by the German Institute for Construction Technology (DIBt) is inserted at a
specific time depending on the type when positioning the slab reinforcement.
The Bole® type Standard is installed from above after positioning the lower layer of slab reinforcement. The movable support frames with
spacers enable easy insertion of the lower reinforcement down to the formwork base. The product is supplied ready to install. No extra
parts are needed for installation ensuring a high degree of reliability. This type is suited for installation on site.
The Bole® type O is installed after positioning the upper layer of slab reinforcement and is therefore also suited for easy and quick
installation on site.
The Bole® type U is installed before positioning the lower reinforcement layer. Supplied with spacers loose. This Bole® type is suitable both
for application on site and in the prefabricating plant.
The Bole® type F has been specially developed for application in the prefabricating plant and fits perfectly in the production process.
The Bole® type K is used for foundation slabs. It is installed by lowering the guide onto the lower reinforcement layer.
Bole®
63
Schöck Bole® Product group 25
Schöck BOLE® O
Schöck Bole® Bolt diameter
14 mm Price in Euros
Bolt height Delivery time Unit with Unit with Unit with Unit with Unit with
in mm 2 bolts 3 bolts 4 bolts 5 bolts 6 bolts
150 - 200 12.20 18.30 24.40 30.50 36.60
210 - 300 B 12.60 18.90 25.20 31.50 37.80
310 - 400 14.30 21.50 28.60 35.80 42.90
Schöck BOLE® U:
Bole®
Schöck BOLE® F
64
Schöck Bole® Product group 25
Bole®
65
66
Schöck ComBAR®
In highly abrasive environments such as bridge end beams, multi-storey car parks, industrial floors and industrial plants as well as construction
components affected by sea water, significant damage due to corrosion occurs when using reinforcing steel.
In such cases, the innovative Schöck ComBAR® reinforcing bar can be a cost-effective long-term alternative to reinforcing steel (in construction
components with crack-bridging coating) or stainless steel. This high-strength material made from glass fibre reinforced polymer is extremely
durable, linearly elastic up to failure, does not conduct electricity or heat and is also easy to machine.
Schöck ComBAR® handles like conventional reinforcing steel for the purposes of design and ordering as well as on site.
ComBAR®
Material
High-strength, durable, chemically
resistant glass fibre reinforced polymer
67
Schöck ComBAR® Product group 25
16
Bar with bolt head 32 to 3.5
D
anchor other diameters
on request
12
Stirrup to 6.0 D
20
Please contact Schöck for price quotations for your construction projects on
Tel.: +49 07223 967-449
Fax: +49 07223 967-490
E-mail: combar@schoeck.de
68
Schöck ComBAR® Thermoanker
The use of steel has been tried and tested in concrete reinforcement for decades. But there are still applications where alternatives are
needed. This is where Schöck ComBAR® comes in. Schöck ComBAR® is a reinforcing bar made from GRP and presents unique benefits
in comparison with steel. Schöck ComBAR® is non-corroding, chemical resistant and easy to cut and has an extremely low thermal
conductivity.
The Schöck ComBAR® cavity wall anchor provides prefabricating plants and architects with a construction material which is a cost-effective
thermal bridge-free alternative to conventional anchoring solutions for insulated double and sandwich walls.
Thermally insulating
Excellent thermal insulation due
to low thermal conductivity. Right
Dimensionally accurate
from the planning stage, the
delivery Schöck ComBAR® Thermoanker can
Economical The dimensionally accurate and guarantee an outer shell connection
ready-to-install anchors for each in double and sandwich walls with
Only approx. 5 anchors with
wall thickness are delivered to the almost no thermal bridge.
12 mm diameter necessary
prefabricating plant. Schöck ComBAR® = 0.5 W/mK;
per m2 (acc. to structural
Comprehensive service requirement). Stainless steel
(Unit = 200 items) non-rusting construction steel =
Technical advice in the design lattice girders are no longer 15W/mK;
phase and on-site support in the required. There is no need for steel = 60W/mK
prefabricating plant. additional connections.
Thermoanker
69
Schöck ComBAR® Thermoanker Product group 25
The Schöck ComBAR® Thermoanker for thermal separation of internally insulated double and sandwich walls manufactured in the
prefabricating plant.
Wall construction:
Outer shell ≥ 70 mm with thermal insulation layer 60-140 mm
inner shell ≥ 60 mm with poured in-situ concrete Price in Euros
Schöck ComBAR® Element Number Metres/box Delivery Price/item Price/unit
Thermoanker length per box Unit time
type in mm
TA 18 180 200 36 B/C 1.19 237.60
TA 20 200 40 1.32 264.00
TA 21 210 42 1.39 277.20
TA 21.5 215 43 1.42 283.80 Schöck ComBAR® Thermoanker
TA 22 220 44 1.45 290.40
TA 25 250 200 50 B/C 1.65 330.00
TA 26 260 52 1.72 343.20
TA 27 270 54 1.78 356.40
TA 28 280 56 1.85 369.60
TA 29.5 295 59 1.95 389.40
TA 30 300 60 1.98 396.00
TA 31 310 62 2.05 409.20
TA 32 320 64 2.11 422.40
TA 33 330 66 2.18 435.60
TA 34 340 68 2.24 448.80
200 B/C
TA 34.5 345 69 2.28 455.40
TA 35 350 70 2.31 462.00
TA 36 360 72 2.38 475.20
TA 36.5 365 73 2.41 481.80
TA 37 370 74 2.44 488.40
TA 40 400 80 2.64 528.00
TA 41 410 82 2.71 541.20
TA 42 420 84 2.77 554.40
TA 45 450 200 90 B/C 2.97 594.00
TA 46 460 92 3.04 607.20
TA 47 470 94 3.10 620.40
TA 48 480 96 3.17 633.60
70
Schöck facing elements
Rationalisation is currently a key consideration for building work. However, with such pressure to keep costs low, it is important that the
quality does not suffer. The Schöck facing element improves the finish of concrete components and plays an important role in rationalising
production. This system enables costs to be reduced while still offering the customer impressive quality. A fact that prefabricating plants can
count on.
Schöck facing
elements
Facing elements for walls
and floor slabs
ASE
71
Schöck facing elements Product group 13
72
Schöck facing elements Product group 13
73
Schöck facing elements Product group 13
Schöck ASE ED
Schöck ASE P
The facing elements are attached to the steel formwork with suitable magnets. Further
Schöck facing elements are available on request.
Carriage-free delivery for 3 pallets and over. Carriage surcharge of EUR 80.00 below 3 pallets
ASE
74
Product range Schöck Isokorb®
Schöck Isokorb® Schöck Isokorb®
Type H [mm] No./Pallet Type H [mm] No./Pallet
160 22
K10-CV35* - K100-CV35* [F90] 160 20 Q10
QXT10 [F90] 180 20
also applies to -V8, -V10, -VV
Q10 + Q10
QXT10 + QXT10 200 18
160 22
[F90] 200 16 Q40
K10-CV35* - K100-CV35* [F90] 180 20
QXT40
also applies to -V8, -V10, -VV
QXT40 + QXT40 200 18
[F90] 160 20 160 22
KF20-CV35* - KF70-CV35*
Q50 [F90] 180 20
160 45 Q50+Q50 200 18
V6/4 180 40
160 22
200 35
Q60 [F90] 180 20
160 45 QXT60 200 18
V6/6 180 40
160 20
200 35
Q70 [F90] 180 18
160 45 QXT70 200 16
V6/8 180 40
160 20
200 35
Q80 [F90] 180 18
160 45 QXT80 200 16
V6/10 180 40
200 35 180 18
Q90 [F90]
180 36 QXT90 200 16
V6/4 [F90]
200 36
160 60
180 36 QP10 [F90] 180 54
V6/6 [F90]
200 36 200 30
180 36 160 20
V6/8 [F90]
200 36 QP20 [F90] 180 20
180 36 200 20
V6/10 [F90]
200 36
160 20
* also applies to CV30 and CV50 from H = 200 mm
QP30 [F90] 180 20
200 20
Product range
T&Cs
75
Product range Schöck Isokorb®
Schöck Isokorb® Schöck Isokorb®
Type H [mm] No./Pallet Type H [mm] No./Pallet
76
Product range Schöck Novomur®, Schöck Tronsole®
Schöck Novomur® Schöck Tronsole®
Type kg/item No./Pallet Type L [mm] H [mm] No./box
20-11.5 9.3 100 160 20
20-15 12.3 80 T 4/T 6/ T 8 1000 180 20
200 20
20-17.5 14.6 60
V 2/V 2 N 63*
20-20 17.0 60
V 4/V 6 42*
20-24 19.4 50
V9 21*
AZ/AZ plus/AZ-S 65
Load-bearing element AZT 20*
Schöck Novomur® light
ZF 16/ZF plus 16 60*
Type kg/item No./Pallet
ZF 18/ZF plus 18/ZF-S 18 60*
6-11.5 7.3 100
ZF 20/ZF plus 20 60*
6-15 9.4 80
F 1.0 Line 45
6-17.5 10.8 60
F-SST 1.0 40
6-20 13.4 60
F 1.2 Line 30
6-24 14.9 50
B-SST 100 x 35 20
PL 60
L-SST/P-SST 50
Sound proofing package 14*
* No./pallet
Product range
T&Cs
77
Conditions of sale and delivery
1 General Conditions loss and accidental deterioration shall pass be fully assigned to us for security purposes. We Should no notification of defect be submitted
The conditions specified in the following shall to the buyer upon the goods' delivery to the herewith revocably authorise the buyer to col- or submitted belatedly, the warranty obligation
be deemed as agreed upon for all contracts, shipping agent (section 447, clause 1 BGB) or, lect the claims assigned to us in his own name for the respective defects shall cease to apply.
deliveries and services. They shall also be ap- at the latest, upon the goods leaving the works and for our account. The buyer shall be obliged c) The buyer shall be solely responsible for the
plicable to all future business transactions with or the delivery warehouse, irrespective of which to disclose the assignment upon request and goods' inspection regarding any damage during
the customer. We do not accept provisions that party bears the freight costs. This shall also be to provide us with any and all information and transport as well as compliance with the ordered
deviate from these conditions unless explicitly applicable if the buyer is a consumer in terms of documents relating thereto. quantities. Should the goods not be inspected
approved in writing. This shall apply in par- section 13 of the BGB and the goods are shipped b) In case of third party access to the reserved upon acceptance or unloading and faulty or
ticular to the customer's conditions, even if we to a different location than the place of delivery goods, particularly with regard to pledging, the similarly deficient goods are then installed, we
have not expressly objected to such conditions upon his request. Section 474 clause 2 BGB shall buyer shall point out our ownership and imme- cannot be held liable for such installation. Any
or have undertaken delivery unconditionally. not be applicable in this instance. diately inform us accordingly. The buyer shall and all defects shall require a written acknowl-
Any modifications of and supplements to a c) Should we – in whole or in part – bear the be liable for any and all costs and damage. edgement on our part. Replaced parts shall be
contract as well as subsidiary agreements shall freight costs, we shall be entitled to specify the c) In the case of the buyer acting contrary to returned to us upon request.
only be binding if they have been confirmed shipping route and the shipping type. Should the terms of the contract – particularly with d) Should we refuse to offer supplemen-
by us in writing. If our conditions are modified, the buyer request a different shipping route regard to late payment – we shall be entitled tary performance or should supplementary
the conditions shall be applicable in their or type and should we accept this request, the to reclaim the reserved goods at the expense performance repeatedly fail, the buyer shall be
changed version as of the date on which they buyer shall bear the extra costs compared to of the buyer or, if applicable, to request the entitled to withdraw from the contract or to
were first received by the customer. the cheapest shipping option. buyer’s assignment of his claim for return reduce the purchase price.
against third parties. All reclaimed goods shall Any and all claims for damage brought forward
2 Offer/Offer Documents 6 Loading be utilised and the utilisation proceeds shall, by the buyer for damage which has not oc-
a) Our offer shall be subject to change unless Passable transport routes shall form a prereq- reduced by reasonable utilisation costs, be curred in the delivery item itself as well as any
otherwise stated in the order confirmation. A cus- uisite for free construction site deliveries. Such offset against the buyer's liabilities. claims for damages founded on entrepreneur
tomer order which constitutes an offer in terms roads shall be passable using loaded, heavy d) Should the reserved goods be installed as a recourse (section 478 BGB) shall be excluded).
of section 145 of the German civil code (BGB) may truck trailers. Should such roads not be avail- fixture on a third party's property by the buyer, Such exemption from liability shall not be
be accepted by us within 2 weeks. If no order able, then any damage which may result and the buyer shall immediately assign any and all applicable to cases involving intention and
confirmation is issued, the order shall be deemed unloading times in excess of one hour per truck claims for compensation which will become gross negligence by the seller, his legal repre-
accepted by the respective delivery or invoice. trailer shall be borne by the buyer. due to the buyer against such third parties or sentatives or his agents. Such exemption from
b) We reserve ownership and copyrights other interested parties to us in the amount of liability shall furthermore not be applicable to
to any and all drawings, illustrations, 7 Terms of payment the reserved goods' value, including all ancillary cases involving defects of specific properties
calculations and other documents. a) Invoices shall fall due for payment no later rights such as the right to the granting of a debt- of the goods warranted or guaranteed by us,
Any disclosure of such documents to third par- than 30 days after the invoice date without any securing mortgage (section 648 BGB) or rights given such warranty or guarantee was aimed
ties by the customer shall require our explicit deductions, unless a different credit term has resulting from rendered securities (section 648 at safeguarding the buyer against the damage
written approval. explicitly been agreed upon. We shall grant a a BGB); we herewith accept such assignment. which has taken place. However, claims for
2% cash discount on the net value of the goods Upon request, the buyer shall be obliged to damages shall, in all cases, be limited to
3 Prices for payment within 14 days. Such cash discount inform us as to whether and when the supplied predictable, typically occurring damage.
In the absence of special agreements, our shall, however, only be granted if no payment building components are installed. The buyer
prices shall be interpreted ex works, including arrears from earlier invoices is outstanding. shall be entitled to obtain the registration of a 10 Product Safety
works loading. Prices are subject to value- b) In case of belated payment, we shall be debt-securing mortgage himself, but shall be We shall not be held liable for any damage re-
added tax at the statutory rate. entitled to charge default interest without obliged to transfer any and all rights from such sulting from any faulty application or improper
prejudice to the assertion of any further dam- mortgage to us upon request. installation of our products.
4 Delivery time age in accordance with section 288, clause 1 e) Should the value of the securities due to us We expressly point out that the goods may
The delivery period shall commence upon dis- BGB (5% above the base rate of the European exceed our overall claim by more than only be used for the contractually specified
patch of the order confirmation but not before Central Bank) or, with mutual commercial 10%, we shall, upon the buyer's request, be or normal intended purpose of the product.
final clarification of all order details. The same transactions, in accordance with section 288, obliged to re-transfer the respective amount, In this context, all applicable constructional
shall also apply to delivery dates. clause 2 BGB (8% above the base rate of the while the securities to be released shall be regulations as well as all potential applications
b) Should the customer fail to timely fulfil any European Central Bank). selected at our sole discretion. and design guidelines contained in building
contractual obligations – also with regard to c) Any cheques and bills of exchange shall f) Any cash payments, bank transfers or cheque control approvals, type certifications and
cooperation and accessory obligations such as only be acceptable subject to security and on payments effected against the provision of a technical documentation shall be strictly
the provision of documents to be furnished by account of payment. Any and all discount and bill of exchange issued by us and accepted by adhered to. Any and all enclosed or attached
the customer, payment of a deposit or similar note charges shall be borne by the buyer. the buyer shall only be deemed as performance processing or mounting instructions or – in the
– we shall be entitled to reasonably postpone d) The buyer shall only be entitled to offset in accordance with sentence 1 if the bill of absence of such instructions – the utilisation of
our delivery periods and dates in accordance counterclaims that are either uncontested exchange has been honoured by the drawer and the products in accordance with state-of-the-
with our production processes’ requirements. or have been recognised by declaratory we have thereby been exempt from bill liability. art science and technology shall always be
c) The date of shipment of goods ex works or judgement. complied with.
warehouse shall be the decisive factor for com- Should the buyer's financial situation deterio- 9 Liability for Defects
pliance with delivery periods and dates. Should rate or should circumstances arise which justify In exclusion of all further claims, we shall be 11 General Restriction of Liability
we fail to timely ship the delivery items without any doubts as to the buyer's capacity to pay, liable for defects within the statutory periods a) As far as the above provisions contain no
any fault on our part, the notification date of particularly with regard to bill of exchange or specified in section 438 BGB as follows: specifications to the contrary, we shall only be
shipping readiness shall be applicable instead. cheque protests, payment delays, payment a) Goods whose usability turns out to be un- held liable for damages brought forward on
The delivery period shall be reasonably arrears from other deliveries or slow payment, serviceable or whose serviceability turns out to the grounds of the infringement of contractual
extended in the case of measures taken in the we are entitled, without prejudice to any and be significantly impaired due to circumstances or extra-contractual obligations in cases of
course of industrial action, particularly strikes all rights otherwise enforceable on our behalf, which have originated prior to the passing intent or gross negligence. This shall also apply
and lockouts, as well as upon the occurrence of to request immediate payment of any and all of risks – particularly due to construction, to cases where the compensation of useless
unforeseeable obstacles that are beyond our outstanding unsettled claims or security and, fabrication, quality, surface quality or other expenditure is claimed. We shall, however,
control, as far as such obstacles have a demon- as far as payment or security does not ensue workmanship deficiencies – shall, according only be held liable for cases involving the
strably significant influence on the completion within a reasonable period, to completely to our reasonably exercised discretion, either intent and gross negligence of non-executive
or supply of the delivery item. This shall also or partially withdraw from the contract. The be repaired or newly delivered free of charge agents if such agents have neglected essential
be applicable to cases where our sub-suppliers buyer undertakes to honour any and all bills of within a reasonable period in exclusion of the contractual obligations.
suffer such occurrences. In important cases, we exchange and cheques provided to us for pay- buyer’s option right (subsequent performance). b) The limitation of our liability for damages
shall inform the customer of the start and finish ment, irrespective of their maturity. Likewise, shall likewise be applicable to the personal
of these kind of hindrances as soon as possible. we shall be entitled to withhold our services aa) The quality shall be based on the average liability for damages of our employees, repre-
e) Should the specified delivery date be ex- until the payment or provision of security quality of the manufacturer's production at the sentatives and agents.
ceeded, the customer shall be entitled to grant should we obtain knowledge of the customer date of delivery. c) Any and all claims in accordance with the
a reasonable period of grace. Should no delivery being subject to any of the above-mentioned Colour deviations are technically unavoidable German product liability law shall remain
be effected by the expiry of such grace period, circumstances after order confirmation. and shall be excluded from liability. unaffected. In such cases, the customer shall
the customer shall be entitled to withdraw from Any non-compliance on the part of the buyer ab) Any references to DIN standards shall be obliged to bring forward his claims for dam-
the contract by means of a written declaration. with the payment obligations or improper generally contain a detailed goods description ages within an exclusion period of six months
Should the delivery delay be founded on an disposal of supplied goods shall entitle us and shall not constitute any warranty as to after discovery or the constructive notice of the
intentional or grossly negligent contractual to discontinue any further deliveries to the any specific condition of the goods, unless liability grounds.
violation on our part, we shall be liable in ac- buyer without prejudice to any further claims such condition has been expressly warranted
cordance with the legal regulations and – except enforceable on our behalf. in writing. 12 Place of Performance, Place of Jurisdiction,
for cases of intentional actions – limited to the ac) In view of constant technical progress, Choice of Law
foreseeable and typically accruing damage. 8 Securities the illustrations and descriptions contained a) The place of performance for our delivery
We shall be entitled to fulfil orders in the form The following securities shall be granted to us in the catalogue and the price lists and on obligations shall be the location of the delivery
of partial deliveries which may not be rejected until the settlement of all claims (including any our homepage shall be non-binding and shall works or the warehouse from which we deliver;
by the customer as long as the remaining and all current account balance claims) which therefore not justify any expectations on the the place of performance for the buyer's pay-
deliveries are supplied within the specified we may be entitled to for any cause in law part of the buyer with respect to any specific ment obligation shall be our company headquar-
delivery period or the partial deliveries made against the buyer now or in the future: properties of the goods which may lead to the ters in Baden-Baden. The place of jurisdiction for
are of reasonable benefit to the customer. In a) The goods shall remain our property (reserved assumption of a material defect in accordance both contractual parties shall be Baden-Baden.
case of mutual commercial transactions, each goods). The buyer shall be entitled to process with section 434 clause 1, sentence 3 BGB. We shall also be entitled to file actions at the
partial delivery shall be deemed an independ- and sell the reserved goods within the scope of b) The customer's compliance with his buyer's general place of jurisdiction.
ent business transaction. orderly business transactions as long as he is not obligation of inspection, notification and b) The German text of the present conditions
g) No call orders shall be acceptable for special in arrears. Any pledging or transfer by way of rejection in accordance with section 377 of as well as our order confirmation shall be
goods. security is prohibited. Should our (co-)ownership the German commercial code (HGB) shall form authoritative. The laws of the Federal Republic
cease due to union, it is hereby agreed that the the prerequisite for our liability for defects. of Germany shall be applicable to the exclusion
5 Passing of Risk buyer's (co-)ownership in the common object Notification of obvious defects shall be given of the applicability of the uniform international
a) The risk shall pass to the buyer ex our works shall pass to us in proportion to its value (invoice in writing, including a specified description of trade law (CISG).
or ex our delivery warehouse, including in value). The buyer shall keep our (co-)ownership such defects, within a period of 10 calendar
respect of partial deliveries undertaken. safely free of charge. Any and all claims arising days after receipt of the goods. The same Schöck Bauteile GmbH
b) If the goods are shipped to the buyer's ad- from the reselling of the reserved goods or on notification period shall apply to latent defects Baden-Baden, January 2005
dress or sent to a different location upon request the basis of other legal grounds (insurance, un-
Product range
78
Legal notice
800004/05.2010/INT