KEY PLAN

YAS ISLAND
REFER TO ENLARGE
PLAN-A
YA
TU S IS
NN LA
EL ND
RO
AD

EXISTING
E 259 413 .59 4 E 259418.951
2.4 80 E 259476.285
N 270 801 N 2708020.911 EXISTING
N 2708107.927 ION SB

PROPOSED CONCRETE PRTECT


E10
EX. LVL=+3.378 LVL=+3.728 E 259423.965 KB 10 NB AIRPORT CITY

IN =5.2 9
E 259831.543

KB KB
E
1.50 WATER PR

CL =3.5
L-1 0
ROAD 1
FOR EXISTING 11KV CABLE

IL
N 2708028.093
E
CABLE JOINT-1

-14
FL SID

B-
IG EN MIDFIELD

1A
E 259412.211 E 259823.435
HT

-
N 2708631.209
T COMPLEX

2-1
RO IAL
LVL=+3.728 E 259478.461 REFER TO SKD-2722 1.00 POWER MASDAR AD

N 2708011.395 1.00 STREET LIGHT N 2708630.791


KHALIFA
CITY
CITY

N 2708106.470 1.00 STREET LIGHT 1.20 TELECOM

XXX X
TOC=+3.820 1.00 ITS NOTES:

KB KB
CABLE IL=3.877
EXISTING CABLE
CABLE LVL=+3.728

1.50 FALCON EYE 1.00 STORMWATER LATERAL XXXX


EXISTING 11KV
CABLE & TILES
LINE KB
X X X X X X X X X X X X

IN =4. 7
1.00

CL 3.1
L-1 84

IN =4. 6
0.12

IL=

CB =5.2 65
RW

3.42
BOUNDARY WALL

CL 3.2
0.68

L-1 96

CL 3.5
0.50

-14

-1- 9
IL=

IN =5.1 4

IL=
RW

CL 3.5
RETAINING

L-1 9
1.06

RETAINING

-14
0.33

0.52

14
0.18

RETAINING

B-
RETAINING

IL=
WALL
RW

WALL

3.00
3.00

2.62
WALL
1.92

3.00
WALL

B-
3.60

3.00

-14
3-4

B-
1.5 CORRIDOR - WATER

1A
B-
2.24
5.00

3-4
-2

1.00
-2
1A
1.0 CORRIDOR - POWER 100.73

1.00
KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB

-3

-3
KB

VERGE

0.10
E 259413.525 KB
10.00m 1.2 CORRIDOR - TELECOM
NEW 11KV

KB
CABLE & TILES
1.0 CORRIDOR - STORM 1m DEPTH FROM FGL L=40.00m L=40.00m

KB

CB =5.2 5
CL 3.4
KB

-1- 9
IL=
KB

14
CARRIAGE WAY
N 2708010.561

B-
1A
12.11

1-
LVL=+2.560
KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB

1.00
KB KB ROAD A

JU
KB KB KB KB KB KB

NC
KB PROP.CONCRETE KB KB KB

TIO
KB

1.00
KB

N7
KB KB KBNEW 11KV KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB
KB

41.72
KB KBMENT
ENCASE CABLE & TILES

12.11
SEE DETAIL-A 1m DEPTH FROM FGL

IL=

MH =5.2 6
3.3

CL 1.8
-1 1
IL=
5

-1
L=80.62m

4B
-1
KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB KB

MH =4. 8

1.00
KB

MH =4.9 7
CL =2.0
-1 73
KB

IL

CL 1.9
-1 7

IN =5.3 3
.261

-1

IL=
L=40.00m

E 259415KB

CL 3.8
IN =4. 9

L-1 3
IN =5.1 4
-1
4B

IN =4. 1

KB
KB

IL=
CL 3.5
CL 2.5

L-1 9
L-1 84

4B
CL 3.3

-14
-3

IL=
L-1 96
IL=

IL=

-14
-2

C-
KC KC KC KC KC KC KC KC KC KC KC KC KC KC KC KC KC KC KC KC

-14

LV

-14
KC

1
B-
RW

B-
N 2708009.482

JO

1A
B-
RW

3-1

-1-
IN

2-
RW

1
T

2
TOC=+3.820 1.80 SEWER
CABLE JOINT-2 NEW 11KV 2.50 STORMWATER
RELOCATED 11KV 1m DEPTH FROM FGL CABLE & TILES
1.00 STORMWATER LATERAL LINE

IN =5.0 5
CL 3.5
L-1 3
1m DEPTH FROM FGL

IL=
E 259420.719

-14 9
CABLE & TILES

B-

1.00K
1B
2.20 IRRIGATION
LVL=+3.728 N 2708017.909

KB
1.50 ITS
RELOCATED 11KV

B
IN =5.1 9
1.50 FALCON EYE

CL 3.6
L-1 4
IN =5.0 1

IL=
CL =3.6
L-1 3

-14
IL

-14

C-
CABLE & TILES

2
B-
1C
E 259864.330
N 2708605.411

00 ISSUED FOR APPROVAL AE 02-06-18

KB

KB
Rev. Description Drw By Date
Status
SHOP DRAWING
Scale Current Issue Signatures
1:1000 Drawn by
ARNOLD E
Original Checked by
A1
Size ANGELINA
LEGEND: Datum WGS84
Approved by
MARWAN
Grid
PROPOSED ROAD LAYOUT 40N C Copyright reserved

EXISTING ROAD & ROAD MARKING


STORMWATER
STREET LIGHTING
DESIGNED DUCTS Contract No.

POTABLE WATER WATER DESIGNED DUCT Client:


PROPOSED ROAD PAVEMENT POWER IRRIGATION DESIGNED DUCT
LV POWER
PROPOSED RETAINING WALL TYPE-1 TELECOM ETISALAT MV DESIGNED DUCT
TELECOM DU LV DESIGNED DUCT Employer:

EXISTING GROUND LEVEL TELECOM MILITARY STL DESIGNED DUCT


WATER TABLE IRRIGATION
SEWER ETISALAT DESIGNED DUCT
RELOCATED 11KV CABLE Consultant:
132kV ITS DESIGNED DUCT
& TILES.
FALCON EYE
P.O Box 5498, Abu Dhabi, UAE
X X X X X EXISTING 11KV CABLE TO BE GAS
RELOCATED.
EXISTING BOUNDARY WALL
ITS ABBREVIATION: Main Contractor:

EXISTING 11KV CABLE PROPOSED STORM WATER LEIGHTON


TO BE RELOCATE TOP INLET
IL PIPE INVERT LEVEL CONTRACTING

PROPOSED CONCRETE ENCASEMENT EXISTING MV CABLE TOP TOP OF PIPE Design Consultant:
DESIGN CONSULTANT

DUCT BANK AECOM Middle East Ltd


PROPOSED STORM WATER MAIN TOC TOP OF CONCRETE TEL. 02 613 4000 P.O. Box 53,
Abu Dhabi, UAE

PROPOSED NEW CABLE & TILES FRL FINISHED ROAD LEVEL Project
PROPOSED STORM WATER AIRPORT INTERCHANGE
EXISTING 11KV CABLE & TILES TO REMAIN SECONDARY AND AIRPORT REGION
EXISTING INLET & PIPE ROAD NETWORK
KB KB KB PROPOSED KERB STONE Title

COMBINED DRAWING OF APPROVED


SKD-3034-REV.01 & SKD-2736-REV.02

Drawing No. Rev.


MU53980/LCAD-284/GD/SKD/3183 00
SD Record Ref. Rev.
SDS-MBS-53980-LCAD-284- 00