General
This design calculation report for the proposed A frame (used as lifting tools) was prepared to
investigate the adequacy of the materials and the safety execution of work in a certain period of
time that the support A- frame will be used.
This report included a 3D model of the structure using Staad Pro V8i as well as extractions of the
design analysis outputs under the loads prescribe by the codes.
3D Model
A - Frame
Proposed Section
W 6x12
W 4x13
DESIGN CALCULATION METHOD STATEMENT
3|Page
MAYNILAD WATER SERVICES, INC
DESIGN AND CONSTRUCTION OF LA MESA WATER TREATMENT PLANT 1
PROCESS IMPROVEMENT WORKS
Built-up 63x63x5
Built-up 170 x 100 x 10
Loading plan
Dead load (self-weight)
Live load
4|Page
MAYNILAD WATER SERVICES, INC
DESIGN AND CONSTRUCTION OF LA MESA WATER TREATMENT PLANT 1
PROCESS IMPROVEMENT WORKS
Detailed Calculation
Section “W 6x12”
Governing Loads
Calculation
1. General Information
(1) Design Code : AISC 360, NSCP 2015
(2) Unit System : N-mm
2. Material
(1) Fu’ : 400 MPa
(2) Fy : 275 MPa
DESIGN CALCULATION METHOD STATEMENT
5|Page
MAYNILAD WATER SERVICES, INC
DESIGN AND CONSTRUCTION OF LA MESA WATER TREATMENT PLANT 1
PROCESS IMPROVEMENT WORKS
3. Section
(1) Section Size : W 6x12
(2) Ix : 9198714.51 mm^4
(3) Iy : 1244531.96mm^4
(4) Section Area : 2322.27 mm^2
4. Forces
(1) Mux : 0.408 kN-m
(2) Muy : -
(2) Vu : 8.01 kN
(3) Pu : 0.262 kN
(4) Tension :-
(5) Torsion :-
6|Page
MAYNILAD WATER SERVICES, INC
DESIGN AND CONSTRUCTION OF LA MESA WATER TREATMENT PLANT 1
PROCESS IMPROVEMENT WORKS
Section “W 4x13”
Governing Loads
Calculation
1. General Information
(1) Design Code : AISC 360, NSCP 2015
(2) Unit System : N-mm
2. Material
(1) Fu’ : 400 MPa
(2) Fy : 275 MPa
3. Section
(1) Section Size : Wide Flange 100 x 100 x 6
(2) Ix : 4703415.11mm^4
(3) Iy : 1606653.3mm^4
(4) Section Area : 2505.43mm^2
4. Forces
(1) Mux : 0.03 kN-m
(2) Muy : 0.09 kN-m
(2) Vu : 0.131 kN
(3) Pu : 5.134 kN
(4) Tension :-
(5) Torsion :-
7|Page
MAYNILAD WATER SERVICES, INC
DESIGN AND CONSTRUCTION OF LA MESA WATER TREATMENT PLANT 1
PROCESS IMPROVEMENT WORKS
Calculation
1. General Information
(1) Design Code : AISC 360, NSCP 2015
(2) Unit System : N-mm
8|Page
MAYNILAD WATER SERVICES, INC
DESIGN AND CONSTRUCTION OF LA MESA WATER TREATMENT PLANT 1
PROCESS IMPROVEMENT WORKS
2. Material
(1) Fu’ : 400 MPa
(2) Fy : 275 MPa
3. Section
(1) Section Size : Built-up 63x63x5
(2) Ix : 390291.7mm^4
(3) Iy : 431237.5mm^4
(4) Section Area : 1160mm^2
4. Forces
(1) Mux : 0.155 kN-m
(2) Muy : 0.204 kN-m
(2) Vu : 4.026 kN
(3) Pu : 4.17 kN
(4) Tension :-
(5) Torsion : 0.204 kN
9|Page
MAYNILAD WATER SERVICES, INC
DESIGN AND CONSTRUCTION OF LA MESA WATER TREATMENT PLANT 1
PROCESS IMPROVEMENT WORKS
Pn = ∅ Fcr Ag = 269.17kN
Calculation
1. General Information
(1) Design Code : AISC 360, NSCP 2015
(2) Unit System : N-mm
2. Material
(1) Fu’ : 400 MPa
(2) Fy : 275 MPa
3. Section
(1) Section Size : Built-up 170 x 100 x 10
(2) Ix : 4175011.67mm^4
(3) Iy : 3168745mm^4
(4) Section Area : 2120mm^2
4. Forces
(1) Mux : 0.009 kN-m
(2) Muy : -
(2) Vu : 0.467 kN
(3) Pu :-
(4) Tension :-
(5) Torsion :-
10 | P a g e
MAYNILAD WATER SERVICES, INC
DESIGN AND CONSTRUCTION OF LA MESA WATER TREATMENT PLANT 1
PROCESS IMPROVEMENT WORKS
Recommendation
We therefore recommend adopting the following sections and sizes including the material
specification stated herein for the design of fabricated A frame with a safe working load of
1000 kg (1 Ton):
W 6x12
W 4x13
Built-up 63x63x5
Built-up 170 x 100 x 10
11 | P a g e