1. INTRODUCTION
A DC-DC converter is a vital part of alternative and renewable energy conversion, portable devices,
and many industrial processes. It is essentially used to achieve a regulated DC voltage from an unregulated
DC source which may be the output of a rectifier or a battery or a solar cell etc. Nevertheless, the variation in
the source is significant, mainly because of the variation in the line voltage, running out of a battery etc., but
within a specified limit. Taking all these into account, the objective is to regulate the voltage at a desired
value while delivering to a widely varying load. A DC-DC switching regulator is known to be superior over a
linear regulator mainly because of its better efficiency and higher current-driving capability. There are
various topologies in the context of DC-DC converters the buck-boost converter are widely used. The basic
circuit of buck-boost converter is shown in Figure 1. The output voltage of a DC-DC converter is controlled
by operating it in the closed loop, and altering its MOSFET (switch) gate signal accordingly. It is basically
governed by a switching logic, thus constituting a set of subsystems depending upon the status (on-off) of the
switch. In the well known pulse width modulation (PWM) technique, the control is accomplished by varying
the duty ratio of an external fixed frequency clock through one or more feedback loops, whenever any
parameter varies. PI controllers are the most widely-used type of controller for industrial applications. They
are structurally simple and exhibit robust performance over a wide range of operating conditions. In the
absence of the complete knowledge of the process, these types of controllers are the most efficient choices.
Power- Management strategies for a grid connected PV-FC hybrid system [1]. Optimized wind energy
harvesting system using resistance emulator and active rectifier for wireless sensor nodes [2]. A hybrid
cascade converter topology with series-connected symmetrical and asymmetrical diode-clamped H-Bridge
cells [3]. An efficient high-step-up interleaved DC-DC converter with a common active clamp [4].
Transformerless grid connected power converter for PV system [5, 6]. Adaptive fuzzy controlled wind
energy system [8]. Distribution voltage control for DC microgrid using stored energy [9]. Predictive
controlled bi-directional inverter for microgrid applications [10]. Characterization and testing of a tool for
photovoltaic panel modeling [11]. Analysis and simulation of characteristics and maximum power point
tracking for photovoltaic systems [12]. Comparison of photovoltaic array maximum power point tracking
techniques [13]. New Approach to Photovoltaic Arrays Maximum Power Point Tracking [14]. Modeling and
Control for a Bidirectional Buck– Boost Cascade Inverter [15]. A Multilevel Inverter for Photovoltaic
Systems with Fuzzy Logic Control [16]. A Direct DC-link Boost Voltage PID-like FuzzyControl Strategy in
Z-Source Inverter [17]. A Maximum Power Point Tracking of PV System by Scaling Fuzzy Control [18]. A
closed -Loop Maximum power point Tracker for Sub watt Photovoltaic Panels [19]. Grid - Connected Boost-
Half-Bridge Photovoltaic Micro inverter System Using Repetitive Current Control and Maximum power
point tracking [20]. Stability of a boost converter fed from a photovoltaic source [21]. Unified Approach to
Reliability Assessment of Multiphase DC-DC Converters in Photovoltaic Energy Conversion Systems [22].
Safety enhanced high stepup DC-DC Converter for AC Photovoltaic Module Application [23]. Optimization
and design of a cascaded DC/DC Converter Devoted to gridconnected photovoltaic System [24]. Controller
design for integrated PV-converter modules under partial shading conditions [25].
The above literature does not cover modelling and simulation of closed loop controlled buck boost
converter inverter based system. Closed loop parallel cascaded buck boost converter inverter system is not
reported in the literature. This work aims to develop closed loop simulink model for buck boost converter -
inverter based solar system.
… … … … 1
∆ … … … … 2
D is the duty cycle. It represents the fraction of the commutation period T during which the switch is
ON. Therefore D ranges between 0 (S is never on) and 1 (S is always on).
During the Off-state, the switch S is open, so the inductor current flows through the load. If we
assume zero voltage drop in the diode, and a capacitor large enough for its voltage to remain constant, the
evolution of IL is
… … … … 3
1
∆ … … … … 4
As we consider that the converter operates in steady-state conditions, the amount of energy stored in
each of its components has to be the same at the beginning and at the end of a commutation cycle. As the
energy in an inductor is given by
1
… … … … 5
2
It is clear that the value of IL at the end of the off state must be the same with the value of IL at the
beginning of the On-state, i.e. the sum of the variations of IL during the on and the off states must be zero
∆ ∆ 0 … … … … 6
1
∆ ∆ 0 … … … … 7
From the above expression it can be observed that the polarity of the output voltage is always
negative (because the duty cycle goes from 0 to 1), and that its absolute value increases with D, theoretically
up to minus infinity when D approaches 1. Apart from the polarity, this converter is either step-up (a boost
converter) or step-down (a buck converter). Thus it is named a buck–boost converter.
Modeling and Simulation of Closed Loop Controlled Parallel Cascaded Buck Boost … (T. Sundar)
651 ISSN: 2088-8694
output voltage equation. It can be calculated as follows, because the inductor current at the beginning of the
cycle is zero, its maximum value at (t=DT) is
… … … … 10
0 … … … … 11
… … … … 12
The load current is equal to the average diode current .The diode current is equal to the inductor
current during the off-state. Therefore, the output current can be written as
… … … … 13
2
… … … … 14
2
… … … … 15
2
Compared to the expression of the output voltage gain for the continuous mode, this expression is
much more complicated. Furthermore, in discontinuous operation, the output voltage not only depends on the
duty cycle, but also on the inductor value, the input voltage and the output current.
The converter operates in discontinuous mode when low current is drawn by the load, and in
continuous mode at higher load current levels. The limit between discontinuous and continuous modes is
reached when the inductor current falls to zero exactly at the end of the commutation cycle.
In this case, the output current (output current at the limit between continuous and
discontinuous modes) is given by:
1 … … … … 16
2
As is the current at the limit between continuous and discontinuous modes of operations, it
satisfies the expressions of both modes. Therefore, using the expression of the output voltage in continuous
mode, the previous expression can be written as:
… … … … 18
2
Let's now introduce two more notations, the normalized voltage, defined by | | . It corresponds
to the gain in voltage of the converter, the normalized current, defined by | | . The term is equal
to the maximum increase of the inductor current during a cycle; i.e., the increase of the inductor current with
a duty cycle D=1. So, in steady state operation of the converter, this means that | | equals 0 for no output
current, and 1 for the maximum current the converter can deliver.
Using these notations, we have
in continuous mode | | ;
in discontinuous mode, | | | |
;
The current at the limit between continuous and discontinuous mode is 1 .
Therefore the locus of the limit between continuous and discontinuous modes is given by
| |
1 1 .
To reduce leakage ground current circulating through PV arrays and ground, several transformerless
inverter topologies were proposed. Even though they can achieve high efficiency, they require more
components than the conventional full-bridge topology. Thus, in this study, the bidirectional full-bridge
inverter is operated with bipolar modulation to avoid leakage ground current and to save power components
while still sustaining comparatively high efficiency to those in. Note that a full-bridge inverter operated with
bipolar modulation can achieve only low frequency common-mode voltage (VC M = (Vdc − Vs ) / 2), resulting
in low leakage ground current.
To maintain the DC-bus voltage for the grid-connected inverter, the controls, such as robust,
adaptive, and fuzzy, were adopted. When adopting these controls for the studied DC-distribution system, a
heavy step-load change at the DC-bus side will cause high DC-bus voltage variation and fluctuation, and the
system might run abnormally or drop into under or over voltage protection. Bulky DC-bus capacitors can be
adopted to increase the hold-up time and suppress the fluctuation of the DC-bus voltage, but it will increase
Modeling and Simulation of Closed Loop Controlled Parallel Cascaded Buck Boost … (T. Sundar)
653 ISSN: 2088-8694
the size and cost of the system significantly. Additionally, even though there are approaches to achieve fast
DC-bus voltage dynamics, the systems with load connected to the DC bus have not been studied yet.
4. SIMULATION RESULTS
Open loop system with step change in insolation is shown in Figure 3. Two buck boost converters
are connected in parallel to increase the power rating. The step change in input due to increase in the solar
energy is shown in Figure 4a. The output voltage of boost converter is shown in Figure 4b. The voltage
increases from 320V to 390V. The AC output voltage and load current are shown in Figure 4c and Figure 4d
respectively. It can be seen that the steady state error in the output voltage and current is higher.
Figure 4a. Input Voltage Figure 4b. Output Voltage of Boost Converter
Figure 4c. Output Voltage of Inverter Figure 4d. Output Current of Inverter
Figure 4. Simulation results of the open loop of two buck boost converters
The Simulink diagram of closed loop system is shown in Figure 5. The DC output voltage of the
boost converter is sensed and it is compared with the reference voltage. The error is processed using a PI
controller. The output of the PI controller is used to update the pulse width applied to the buck boost
converter. The step change in input voltage is shown in Figure 6a. The input voltage increases from 10V to
14V. The output of the boost converter is shown in Figure 6b. The output decreases and settles at 240V. The
output voltage and current waveforms are shown in Figure 6c and Figure 4d respectively. They are inphase
since the load is a resistive load.
Figure 6a. Input Voltage Figure 6b. Output Voltage of the Boost Converter
Figure 6c. Output Voltage of the Inverter Figure 6d. Output Current of the Inverter
Figure 6. Simulation results of the closed loop of two buck boost converters
5. CONCLUSION
Closed loop controlled parallel cascaded buck boost converter inverter system is successfully
modelled and simulated using sim power system. The results of open loop and closed loop systems are
presented. The closed loop system is capable of reducing the steady state error. The simulation results are in
line with the predications. The closed system has advantages like improved response and reduced steady state
Modeling and Simulation of Closed Loop Controlled Parallel Cascaded Buck Boost … (T. Sundar)
655 ISSN: 2088-8694
error. The disadvantage of this system is that it has limited voltage tracking range. The contribution of this
work is to propose a parallel cascaded buck boost converter to improve the npower rating and reduce the
inverter input current ripple.
The scope of this work is the simulation of closed loop controlled converter-inverter system with PI
controller. The closed loop simulation using fuzzy controller will be done in future.
REFERENCES
[1] L.N. Khanh, J.J. Seo, T.S. Kim and D.J. Won, “Power Management strategies for a grid connected PV-FC hybrid
system”, IEEE Trans. Power Devliv., vol. 25, no. 3, pp. 1874-1882, Jul. 2010.
[2] Y.K. Tan and S.K. Panda, “Optimized wind energy harvesting system using resistance emulator and active rectifier
for wireless sensor nodes”, IEEE Trans. Power Electron, vol. 26, no. 1, pp. 38-50, Jan. 2011.
[3] A. Nami, F. Zare, A. Ghosh, and F. Blaabjerg, “A hybrid cascade converter topology with series-connected
symmetrical and asymmetrical diode-clamped H-Bridge cells”, IEEE Trans. Power Electron, vol. 26, no. 1, 51–65,
Jan. 2011.
[4] S. Dwari and L. Parsa, “An efficient high-step-up interleaved dc–dc converter with a common active clamp”, IEEE
Trans. Power Electron, vol. 26, no. 1, pp. 66–78, Jan. 2011.
[5] J.M. Shen, H.L. Jou, and J.C. Wu, “Novel transformerless grid connected power converter with negative grounding
for photovoltaic generation system”, IEEE Trans. Power Electron, vol. 27, no. 4, pp. 1818–1829, Apr. 2012.
[6] T. Kerekes, R. Teodorescu, P. Rodriguez, G. Vazquez, and E. Aldabas, “A new high-efficiency single-phase
transformerless PV inverter topology”, IEEE Trans. Ind. Electron, vol. 58, no. 1, pp. 184–191, Jan. 2011.
[7] S.V. Araujo, P. Zacharias, and R. Mallwitz, “Highly efficient single-phase transformerless inverters for grid-
connected photovoltaic systems”, IEEE Trans. Ind.Electron, vol. 57, no. 9, pp. 3118–3128, Sep. 2010.
[8] M.A. Azzouz and A.L. Elshafei, “An adaptive fuzzy regulation of the dc-bus voltage in wind energy conversion
systems”, in Proc. 2010 IEEE Int. Conf. CCA, pp. 1193–1198.
[9] H. Kakigano, A. Nishino, Y. Miura, and T. Ise, “Distribution voltage control for dc microgrid by converters of
energy storages considering the stored energy”, in Proc. 2010 IEEE ECCE, pp. 2851–2856.
[10] T.F. Wu, K.H. Sun, C.L. Kuo, and C.H. Chang, “Predictive current controlled 5 kW single-phase bi-directional
inverter with wide inductance variation for DC-microgrid applications”, IEEE Trans. Power Electron, vol. 25, no.
12, pp. 3076–3084, Dec. 2010.
[11] F. Adamo, F. Attivissimo, A. Di Nisio, and M. Spadavecchia, “Characterization and testing of a tool for
photovoltaic panel modeling”, IEEE Trans.Instrum. Meas., vol. 60, no. 5, pp. 1613–1622, May 2011.
[12] T.C. Yu and T.S. Chien, “Analysis and simulation of characteristics and maximum power point tracking for
photovoltaic systems”, in Proceedings of the International Conference on Power Electronics and Drive Systems
(PEDS ’09), pp. 1339–1344, January 2009.
[13] T. Esram and P.L. Chapman, “Comparison of photovoltaic array maximum power point tracking techniques”, IEEE
Trans. Energy Convers, vol. 22, no. 2, pp. 439–449, Jun. 2007.
[14] Brambilla. A, Gambarara. M, Garutti. A, Ronchi. F, “New Approach to Photovoltaic Arrays Maximum Power
Point Tracking”, 30th Annual IEEE Power Electronics Specialists Conference, Vol. 2, pp. 632 - 637, 1999.
[15] Honglin Zhou, Shuai Xiao, Geng Yang, Hua Geng, "Modeling and Control for a Bidirectional Buck– Boost
Cascade Inverter", IEEE Transactions on power electronics, Vol. 27, No. 3, March 2012, pp 1401-1413.
[16] C. Cecati, F. Ciancetta, and P. Siano, "A Multilevel Inverter for Photovoltaic Systems With Fuzzy Logic Control",
IEEE Transactions on Industrial Electronics, Vol. 57, No. 12, December 2010 pp. 4115-4125.
[17] X.P. Ding, Z.M. Qian, S.T. Yang, B. Cui, and F.Z. Peng. “A Direct DC-link Boost Voltage PID-like Fuzzy Control
Strategy in Z-Source Inverter”, IEEE, 2008, pp. 405-411.
[18] Y.H. Chang and C.Y. Chang, "A Maximum Power Point Tracking of PV System by Scaling Fuzzy Control",
presented at International Multi Conference of Engineers and Computer Scientists, Hong Kong, 2010.
[19] Oscar Lopez-Lapena, Maria Teresa Penella, and Manel Gasulla. 2012. “A closed -Loop Maximum power point
Tracker for Sub watt Photovoltaic Panels”. IEEE Transactions on Industrial Electronics. 59(3).
[20] Shuai Jiang, Dong Cao, Yuan Li and Fang Zheng Peng. 2012. “Grid - Connected Boost-Half-Bridge Photovoltaic
Micro inverter System Using Repetitive Current Control and Maximum power point tracking”. IEEE Transactions
on power Electronics. 27(11).
[21] Abdullah Abusorrah, Mohammed. M., Al-Hindawi, Yusuf Al-Turki, Kuntal Mandal, Damian Giaouris, Soumitro
Banerjee, Spyros Voutetakis and Simira Papadopoulou. 2013. “Stability of a boost converter fed from a
photovoltaic source”. Solar energy. 98: 458-471.
[22] Sairaj V. Dhople, Ali Davoudi, Alejandro D. Dominguez-Garcia and Patrick L. Chapman. 2012. “A unified
Approach to Reliability Assessment of Multiphase DC-DC Converters in Photovoltaic Energy Conversion
Systems”. IEEE Transactions on power Electronics. 27(2).
[23] Shih-Ming Chen, Tsorng Juu, Liang, Lung Sheng and Jiann Fuh Chen. 2012. “A safety enhanced high stepup DC-
DC Converter for AC Photovoltaic Module Application”. IEEE Transactions on power electronics. 27(4).
[24] Stephane vighetti, jean-Paul ferrieux and Y veslembeye. 2012. “Optimization and design of a cascaded DC/DC
Converter Devoted to gridconnected photovoltaic System”. IEEE Transaction on power electronics. 27(4).
[25] Chong B.V. P and Zhang. L. 2012. “Controller design for integrated PV-converter modules under partial shading
conditions”. Solar energy. 92: 123-138.
BIOGRAPHIES OF AUTHORS
S. Sankar obtained his B.E Degree in Electrical & Electronics Engineering at Sri Venkateswara
College of Engineering, from Madras University and M.E (Power System) Degree from
Annamalai University Chidambaram. He has done his Ph.D in the area of FACTS controllers.
His research interests are in the area of FACTS and PV systems. He has published papers on
IPFC and Converter.