NR Electric Co., Ltd.

PCS-9691E
Overcurrent Relay

The PCS-9691E overcurrent relay is designed for fast and


selective protection, control and monitoring of feeders, shunt
Functions
capacitor banks, reactors or motors etc. in directly grounded, Protection
impedance grounded, Peterson coil grounded or ungrounded • Three-stage phase overcurrent protection. (50/51P)
system.
• Three-stage neutral overcurrent protection. (50/51G)

• Three-stage negative sequence overcurrent protection. (51Q)

• Directional ground time overcurrent protection. (67G)

• Breaker failure protection. (51BF)

• Thermal overload protection. (49)

Functional Block Diagram

Read more on the web


www.nrelect.com 75
NR Electric Co., Ltd.

• Broken conductor protection. (46BC)


Features
• Undervoltage/overvoltage protection. (27/59)
• O n t h e p r e m i s e o f 3 2 s a m p l e s p e r c y c l e , a l l d a ta
• Multi-slot three-pole auto-reclosing (Up to 3 slots). (79) measurement, calculation and logic discrimination could be
done within one sampling period. The event recording and
• Ten (10) available curves complied with ANSI and IEC
protection logic calculation are completed simultaneously.
standard. (IDMT)

• Thermal model overload curve. • Definite time and inverse time of phase overcurrent
protection are both provided.
• Voltage transformer supervision. (VTS)

• Current transformer supervision. (CTS) • Definite time and inverse time of zero sequence overcurrent
• Current drift auto-adjustment. protection are both provided.

Metering and monitoring • This relay constantly measures and calculates analog
• Tripping/Closing circuit supervision quantities for metering including phase current and zero
sequence current.
• Circuit breaker status monitoring

• Operation time supervision of breaker • This relay is equipped with two EIA RS-485 standardized
electrical interfaces for uplink communication.
• 256 SOE records, including tripping, alarm, change of binary
inputs and self-check.
• This relay can communication with SAS or RTU, the
• Eight (8) wave records, up to 4.5 seconds for each wave communication protocol of this device is IEC60870-5-103,
record, compatible with COMTRADE format. Modbus or DNP3.0.

• Supervision of tripping time, CBF starting current, CB


• Event recording function: 32 latest fault reports (up to 8
switching counter, CB travelling time and internal relay fault.
records in a report), 64 alarm records and 256 records of
time tagged sequence of event can be recorded.

Control • Perfect fault and disturbance recording function: 3 latest fault


• 10 configurable binary inputs waves. the fault and disturbance file format is COMTRADE.

• 7 binary outputs for DC voltage (including 4 configurable


• This device can store settings, history reports and fault
contacts), 9 binary outputs for AC voltage (including 6
waves in a 2Mbit FRAM, which means the information will
configurable contacts)
not be lost even if the power supply is switched off.
• 8 LEDs, including 4 configurable LEDs

• Local/remote opening/closing logic of breaker

• Faceplate buttons for local control of breaker

Communication and HMI


• One RS-232 port for testing

• Two RS-485 ports for communication with SCADA

• IEC 60870-5-103 DNP 3.0 serial, and MODBUS protocol

• RCS-PC assistant software for testing

• Clock Synchronization

76 Read more on the web


www.nrelect.com