2G CMD

You might also like

Download as txt, pdf, or txt
Download as txt, pdf, or txt
You are on page 1of 3

rldep:cell=all; Internal or external in BSC

mgcep:cell=all; iNNER in MSC


Alarm
mgcep:cell=16832A;
RXTCP:MOTY=RXOTG,CELL=16832A;
rxmfp:mo=rxocf-432,faulty;

Alarm list viewer

The following is a summary of commands used in these procedures:


ALLIP;-Print Alarm

list-Print status of:


RXTCP:MOTY=RXOTG,CELL=34652B;-Print TG connected to Cell
RXTCP:MO=RXOTG-XX;-Print Cells connected to TG

RXASP:MO=RXOTG-68; !ALARMS & site name!


RXASP:MO=RXOCF-68;
RXMFP:MO=RXOCF-68;

RXTCP:MOTY=RXOTG,CELL=34652B;
rxmsp:mo=rxocf-TG No,subord; !To check the traffic

RXMSP:MO=RXOCF-68; Control Function


RXMSP:MO=RXOTF-116; Timing Function
RXMSP:MO=RXOIS-68; Interconnect Switch
RXMSP:MO=RXOTRX-68-2&&-5; Transceiver Controller
RXMSP:MO=RXOTX-68-0&&-7; Transmitter
RXMSP:MO=RXORX-116-0&&-7; Receiver
RXMSP:MO=RXOTS-68-2-0&&-7; Time Slots

RXMFP:MO=RXOXX;-Print faults on MO
RXMFP:MO=RXOTG-68; !ERRORCNT!
RXMFP:MO=RXOTRX-68-0&&-7;
RXMFP:MO=RXOTS-68-4-0&&-7;
RXMFP:MO=RXOCF-189;

RXELP:MO=RXOTG-116;-Print Error log of MO

RLCRP:CELL=34652B;-Print Cell Resources

Unused TS
rxmop:moty=rxotx;
rlcrp:cell=34652B;
rxmop:mo=rxotg-68;
rxmop:mo=rxotrx-68-0&&-7;
rxmop:mo=rxotx-68-0&&-7;
rxmop:mo=rxots-68-0-0&&-7;
CHECK digital path quality
RXCDP:MO=RXOTG-68;-TRX freq
RXAPP:MO=RXOTG-68;-Print RBLT24 devices conn. to TG
DTSTP:DIP=XXRBLT;-Status DIP
STDEP:DEV=RBLT24-XX&&-YY;-Print status of device range
RXMOP:MO=RXOXXX; Print MO definitio
DTQUP:DIP=XXRBLT;-Print DIP hits
RXMDP:MO=RXOCF-68;-Print devices connected to CF
RXMDP:MO=RXOTRX-68-2; � � � TRX
RXMDP:MO=RXOTS-68-2-0&&-7; � � � TS
RLCFP:CELL=16591A;-Print channel numbers for Cell
RLDEP:CELL=PLXXXA;-Print Cell definition
RLSTP:CELL=PLXXXA;-Print Cell status

cell resources

IOEXP; check the BSC upgrade


rxmfp:mo=rxocf-17; (RBS TYPE)
RLCFP:CELL=CSTABAR;(ARFCN List)
RLCRP:CELL=CSTABAR;(Cell resources & external interference)
RLCDP:CELL=CSTABAR;(Cell Multiple Channel Alloc Prof)
RLDEP:CELL=CSTABAR;(Cell Design Data)
RLMFP:CELL=CSTABAR;(Measurement Freq)
RLNCP:CELL=CSTABAR;(neighbour relations)
RLNRP:CELL=CSTABAR;(cell relations)
RLLHP:CELL=CSTABAR;(HCS)
RLLCP:CELL=CSTABAR;(Cell Load Sharing)
RLSSP:CELL=16591A;(SYSINFO)
RLSLP:CELL=CSTABAR;(# of SDCCH resources)
RAEPP:ID=ALL;(BSC parameters)
RRTPP:TRAPOOL=ALL;(per BSC command)
EXRPP:RP=ALL;(check number of rpps1 in the bsc)
EXEMP:RP=ALL,EM=ALL;(check rpps)
RLGRP:CELL=ALL,DETAIL;(check B-PDCH,E-PDCH)
RLGRP:CELL=CSTABAR;(GPRS resources)
RLGSP:CELL=CSTABAR;(GPRS Config Data)
STDEP: DEV=RTGPHDV-0&&-127;(Check RPP
c7ltp:ls=all; (BSC TRC)
rlnrp:cell=34102C,cellr=34667c; (NEIGHBOUR RELATION DATA)
RLDHP:CELL=34102A; (Half rate)
rlcpp:cell=09101A; (power)
rahep; (TRH LOAD THRESHOLD EXCEEDED)
raepp:id=MAXLOAD;
nsstp; ! check synchronization !
nsdap; ! check WDL !
dbtsp:tab=axepars,NAME=EGPRSBPCLIMIT;

-------------------------------HW-------------
allip; !all alarm!
allip:acl=a1; !pour cheki les alarms a1(critical), ou a2(major), ou
a3(minor)!
allip:alcat=APZ; !contriole(APZ)exp(AP syst.), telephonique??? APT!
allip:acl=A3,alcat=APt;
allip:alcat=power; !tou les alarms relatives a la partie power!
allip:alcat=ALL; !tou les alarms relatives a la partie
external(clim,..)!
dbtsp:tab=saactions; !voir les alarm DATABASE TABLE et datatail size
alteration!