Structural Design Calculations: Hanson Stair Header
Structural Design Calculations: Hanson Stair Header
References:
1. ASCE/SEI 7-10, Second Edition, Minimum Design Loads for Buildings and Other Structures,
American Society of Civil Engineers (ASCE)
2. 2014 Oregon State Structural Specialty Code (OSSC)
3. 2012 International Building Code (IBC)
4.
5. 2012 National Design Specification for Wood Construction, ANSI/AWC (NDS)
Table of Contents
EXISTING
FRAMING
NEW P1 BELOW
FRAMING
BELOW
B3 B2
(E) 2-2X10
(E) 2-2X10
B1
EXISTING BEAM
ABOVE
P1
B3 EXTERIOR
B2
WALL LINE
(E) 2-2X10 ABOVE
3'
(E) 2-2X10
11.25'
B1
3' 10.5'
3 FT
SEE SH. 9
218
7 1863
273 70
1559
411 218
11
2.5"
SEE SH. 12
CODE REFERENCES
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
Load Combination Set : IBC 2015
Material Properties
Analysis Method : Allowable Stress Design Fb + 2,600.0 psi E : Modulus of Elasticity
Load Combination :IBC 2015 Fb - 2,600.0 psi Ebend- xx 2,000.0 ksi
Fc - Prll 2,510.0 psi Eminbend - xx 1,016.54 ksi
Wood Species : Fc - Perp 750.0 psi
Wood Grade : Fv 285.0 psi
Ft 1,555.0 psi Density 42.0 pcf
Beam Bracing : Beam is Fully Braced against lateral-torsional buckling
Applied Loads Service loads entered. Load Factors will be applied for calculations. .
Uniform Load : D = 0.0150, L = 0.040 ksf, Tributary Width = 5.250 ft, (2nd floor)
Uniform Load : D = 0.0150, L = 0.040 ksf, Tributary Width = 1.50 ft, (stair)
CODE REFERENCES
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
Load Combination Set : IBC 2015
Material Properties
Analysis Method : Allowable Stress Design Fb + 900.0 psi E : Modulus of Elasticity
Load Combination :IBC 2015 Fb - 900.0 psi Ebend- xx 1,600.0 ksi
Fc - Prll 1,350.0 psi Eminbend - xx 580.0 ksi
Wood Species : Douglas Fir - Larch Fc - Perp 625.0 psi
Wood Grade : No.2 Fv 180.0 psi
Ft 575.0 psi Density 31.20 pcf
Beam Bracing : Beam is Fully Braced against lateral-torsional buckling
Applied Loads Service loads entered. Load Factors will be applied for calculations. .
Load for Span Number 1
Uniform Load : D = 0.0150, L = 0.040 ksf, Tributary Width = 1.30 ft
CODE REFERENCES
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
Load Combination Set : IBC 2015
Material Properties
Analysis Method : Allowable Stress Design Fb + 900.0 psi E : Modulus of Elasticity
Load Combination :IBC 2015 Fb - 900.0 psi Ebend- xx 1,600.0 ksi
Fc - Prll 1,350.0 psi Eminbend - xx 580.0 ksi
Wood Species : Douglas Fir - Larch Fc - Perp 625.0 psi
Wood Grade : No.2 Fv 180.0 psi
Ft 575.0 psi Density 31.20 pcf
Beam Bracing : Beam is Fully Braced against lateral-torsional buckling
Applied Loads Service loads entered. Load Factors will be applied for calculations. .
Uniform Load : D = 0.0150, L = 0.040 ksf, Tributary Width = 0.6670 ft
Vertical Forces
Reactions Support notation : Far left is #1 .
Maximum & Stresses for Load Combinations
Load Combination Support 1 Support 2
Overall MAXimum 0.327 0.327
Overall MINimum 0.258 0.258
+D+H
D Only 0.069 0.069
Lr Only
L Only 0.258 0.258
S Only
.
Code References
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
Load Combinations Used : IBC 2015
General Information
Analysis Method : Allowable Stress Design Wood Section Name 4x4
End Fixities Top & Bottom Pinned Wood Grading/Manuf. Graded Lumber
Overall Column Height 7.5 ft Wood Member Type Sawn
( Used for non-slender calculations )
Exact Width 3.50 in Allow Stress Modification Factors
Wood Species Douglas Fir - Larch Exact Depth 3.50 in Cf or Cv for Bending 1.50
Wood Grade No.2 Cf or Cv for Compression
Area 12.250 in^2 1.150
Fb + 900.0 psi Fv 180.0 psi
Ix Cf or Cv for Tension 1.50
12.505 in^4
Fb - 900.0 psi Ft 575.0 psi Iy Cm : Wet Use Factor
12.505 in^4 1.0
Fc - Prll 1,350.0 psi Density 31.20 pcf Ct : Temperature Factor 1.0
Fc - Perp 625.0 psi Cfu : Flat Use Factor 1.0
E : Modulus of Elasticity . . . x-x Bending y-y Bending Axial Kf : Built-up columns 1.0 NDS 15.3.2
Basic 1,600.0 1,600.0 1,600.0 ksi Use Cr : Repetitive ? No
Minimum 580.0 580.0 Brace condition for deflection (buckling) along columns :
X-X (width) axis : Unbraced Length for X-X Axis buckling = 7.5 ft, K = 1.0
Y-Y (depth) axis : Unbraced Length for X-X Axis buckling = 7.5 ft, K = 1.0
Applied Loads Service loads entered. Load Factors will be applied for calculations. .
Column self weight included : 19.906 lbs * Dead Load Factor
AXIAL LOADS . . .
Axial Load at 7.50 ft, D = 1.559, L = 1.863 k
DESIGN SUMMARY .
Code References
Calculations per ACI 318-14, IBC 2015, CBC 2016, ASCE 7-10
Load Combinations Used : IBC 2015
Analytical Values
d - Slab Thickness 4.0 in Ks - Soil Modulus of Subgrade Reaction 100.0 pci
FS - Req'd Factor of Safety Ec - Concrete Elastic Modulus 3,122.0 ksi
3.0 : 1
f'c - Concrete Compressive Strength 2.50 ksi
µ - Poisson's Ratio 0.150
φ - LRFD Reduction Factor 0.850
Min. Adjacent Load Distance 30.473 in
Analysis Formulas
Pn = 1.72 [ (Ks R1 / Ec) 10,000 + 3.6] Fr d^2 Min Adjacent Column Distance = 1.5 * ( [ Ec d^3 / (12 * ( 1- u^2 ) Ks ] ^ 1/4 )
Ks = Soil modulus of subgrade reaction Ec = Concrete elastic modulus
R1 = 50% plate average dimension * sqrt( PlWid * PlLen) /2 d - Slab Thickness
Ec = Concrete elastic modulus u - Poisson's ratio
Fr - Concrete modulus of rupture = 7.5 * sqrt( f'c ) Ks = Soil modulus of subgrade reaction
d - Slab Thickness
POST 3.50 3.50 1.75 1.56 ###.## +1.20D+0.50Lr+1.60L 2982.7 36.5 Fail, FS= 0.01 < 3