Dual-Band Combiner

690 - 2180 MHz 2400 - 2700 MHz


LTE 800 / CDMA 850 / GSM 900 / GSM 1800 / UMTS 2100 WiMAX / LTE 2600

• Designed for co-siting purposes Unit 2


• Enables feeder sharing Port 3
• Can be used as a combiner near the BTS or Port 1
in a reciprocal function near the antenna
• Suitable for indoor or outdoor applications
Port 2
• Wall or mast mounting
• Double unit for XPol antennas
• Built-in lightning protection Unit 1
• External DC stop available as an accessory
• Extremely small dimensions and low
weight
• Very low insertion loss
• High input power

Technical Data

Type No. 78211189


Double Unit
Pass band
Band 1 690 - 2180 MHz
Band 2 2400 - 2700 MHz
Insertion loss
Port 1 ↔ Port 3 < 0.2 dB (690 - 2180 MHz) typ. 0.1 dB
Port 2 ↔ Port 3 < 0.15 dB (2400 - 2700 MHz) typ. 0.1 dB
Isolation
Port 1 ↔ Port 2 > 50 dB (690 - 2180 MHz), > 48 dB (2400 - 2700 MHz)
VSWR < 1.22 (690 - 2180 MHz)

< 1.2 (2400 - 2700 MHz)


Impedance 50 Ω
Subject to alteration.

Input power
Band 1 / Band 2 < 500 W / < 500 W
Intermodulation products < -160 dBc (3rd order; with 2 x 20 W)
Temperature range -55 ... +60 °C
Connectors 7-16 female (long neck)
Application Indoor or outdoor (IP 66)
DC/AISG transparency Unit 1 Unit 2
Port 1 ↔ Port 3 By-pass (max. 2500 mA) Stop
936.4558a

Port 2 ↔ Port 3 Stop By-pass (max. 2500 mA)


Lightning protection 3 kA, 10/350 μs pulse Without lightning protection
Mounting Wall mounting: With 4 screws (max. 8 mm diameter) /
Mast mounting: With additional clamp set
Weight 2.8 kg
Packing size 266 x 196 x 180 mm
Dimensions (w x h x d) 141 x 119 x 98.5 mm (without connectors, without mounting brackets)

www.kathrein.de 78211189 Page 1 of 4

KATHREIN-Werke KG . Anton-Kathrein-Straße 1 – 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-820
Dual-Band Combiner
690 - 2180 MHz 2400 - 2700 MHz
LTE 800 / CDMA 850 / GSM 900 / GSM 1800 / UMTS 2100 WiMAX / LTE 2600

Accessories (order separately)

Type No. Clamp set suitable for mast diameter of Clamp Set
734360 34 - 60 mm
734361 60 - 80 mm
734362 80 - 100 mm
734363 100 - 120 mm
734364 120 - 140 mm
734365 45 - 125 mm

Type No. Clamp set suitable for mast diameter of DC stop 50-Ohm load
78210850V01 DC stop
78410367 50-Ohm load

Typical Attenuation Curves

Please Note:

The mounting plates can be removed by loosening the screws  to  (M5 x


12) and replaced with other means of mounting, always provided that the max.
drilled depth of 7.5 mm is respected with the choice of replacement screws.

As a result of more stringent legal regulations and judgements regarding


product liability, we are obliged to point out certain risks that may arise
when products are used under extraordinary operating conditions.

Extraordinary operating conditions, such as heavy icing or exceptional dynamic


stress (e.g. strain caused by oscillating support structures), may result in the
breakage of a mast mounted device or even cause it to fall to the ground.

These facts must be considered during the site planning process.

The Dual-band Combiners are designed to operate under the environmental


conditions as described in ETS 300 019-1-4 class 4.1 E and have passed
environmental tests as recommended in ETS 300 019-2-4.

The installation team must be properly qualified and also be familiar with
the relevant national safety regulations.

The details given in our data sheets have to be followed carefully when
installing the combiners and accessories.

The limits for the coupling torque of RF connectors,


recommended by the connector manufacturers
must be obeyed.

Terminate unused inputs with a suitable 50-Ohm


load, e.g. 784 10367.
Subject to alteration.
Any previous datasheet issues have now become
invalid.
936.4558a

Page 2 of 4 78211189 www.kathrein.de


KATHREIN-Werke KG . Anton-Kathrein-Straße 1 – 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-820
Dual-Band Combiner
690 - 2180 MHz 2400 - 2700 MHz
LTE 800 / CDMA 850 / GSM 900 / GSM 1800 / UMTS 2100 WiMAX / LTE 2600

Application example
Subject to alteration.
936.4558a

www.kathrein.de 78211189 Page 3 of 4

KATHREIN-Werke KG . Anton-Kathrein-Straße 1 – 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-820
Dual-Band Combiner
690 - 2180 MHz 2400 - 2700 MHz
LTE 800 / CDMA 850 / GSM 900 / GSM 1800 / UMTS 2100 WiMAX / LTE 2600

Dimensions

Front view

Side view

Top view

Subject to alteration.
936.4558a

Bottom view

Page 4 of 4 78211189 www.kathrein.de


KATHREIN-Werke KG . Anton-Kathrein-Straße 1 – 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-820
General Information
about Panel Antennas

Environmental Kathrein cellular antennas are designed to operate under the environmental ­conditions
­conditions: as described in ETS 300 019-1-4 class 4.1 E.
The antennas exceed this standard with regard to the following items:
– Low temperature: –55 °C
– High temperature (dry): +60 °C
For antennas equipped with FlexRET: The electrical downtilt adjusting is designed to
operate under the environmental conditions as described in the valid data sheet of the
FlexRET.

Ice protection: Due to the very sturdy antenna construction and the ­protection of
the radiating system by the r­adome, the antenna remains operational even under icy
­conditions.

Environmental Kathrein antennas fulfil the stated specifications after completion of the environmental
tests: tests as defined in ETS 300 019-2-4. The homogenous d ­ esign of Kathrein’s antenna
­families uses ­identical modules and materials.
Extensive tests have been performed on typical samples and modules. The vibration
test has been adapted relating to frequency and acceleration to the conditions of mast
mounted antennas.

Please note: As a result of more stringent legal regulations and judgements regarding product
liability, we are obliged to point out certain risks that may arise when products are
used under extraordinary ­operating conditions.

The mechanical design is based on the environmental conditions as ­stipulated in


ETS 300 019-1-4. Wind loads are ­calculated according to ­DIN 1055-4.
The antennas may be used at locations where the anticipated peak wind velocity or
gust wind speed lies within the maximum wind speed listed in the data sheet. We
warrant the mechanical s­afety and electrical functionality under such conditions.
­
The wind speeds are defined in ­accordance with the DIN, EN or TIA standards. This
­warranty makes ­allowance for the partial safety factors specified in those standards.
Extraordinary ­operating conditions, such as heavy icing or exceptional d ­ ynamic stress
(e.g. strain caused by oscillating support structures), may result in the b
­ reakage of an
­antenna or even cause it to fall to the ground. These facts must be c ­ onsidered during
the site planning process.

The details given in our data sheets have to be f­ ollowed carefully when i­nstalling
the antennas and a ­ ccessories.
Site planning and installation must be carried out by qualified and ­experienced
staff. All relevant national safety regulations must be upheld and respected.
­Incorrect site planning, faulty installation, as well as i­nterfering surroundings
on site, may lead to deviations in the ­electrical parameters compared to those
­specified in the respective data sheets.
The connectors on this product are only suitable for connecting to the ­compatible
counterpart. Please ensure that the connected cable has been ­ fitted with a
­connector of the same standard, otherwise damage may occur.

The tilt values will be set to any arbitrary value in the given tilt range. These values
Subject to alteration.

are independent from the frequency band or antenna type and can vary between
antennas and bands.

EU-RED Hereby, Kathrein Werke KG declares that the radio equipment is in compliance with
Directive 2014/53/EU. The full text of the EU declaration of conformity is available at
the following internet address: http://www.kathrein.com
936.4694/d

Our quality assurance system and our RoHS Our products are compliant to the
environmental management system apply EU Directive RoHS as well as to other
to the entire company and are certified environmentally relevant regulations
by TÜV according to EN ISO 9001 and (e.g. REACH).
EN ISO 14001.

Any previous data sheet issues have now become ­invalid. Page 1 of 1
www.kathrein.com
KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820

You might also like