93 C.W. PLANT
Circulating water pump house has pumps for condensing the steam for condenser.
Five pumps are used for condensing Unit No.1 & 2 and afler condensing this water is
discharged back into the river, Each pump has capacity of 8275 M°/Hr, and pressure about
1.94 Kg/e *, Three seal water pump are used for sealing circulating water pump shaft at pr.
4Skgse ?.
Two pump for unit 1 & 2 with one standby is used for supplying raw water to
chlrofied chemical dosing is tone between and chlorified water is taken through main line.
From main line water passes through filter bed to filter the water. Chlorified water is pumped
to 42 m elevation by two pumps of capacity 270 Mi/Inch at discharge pressure of 6.9
KgJe *. At 42M elevation the water is stored im tank and used for cooling the oil coolers
and retumed back to river. Oil coolers are situated on ground and there are no. of tress for
each unit,