Professional Documents
Culture Documents
Dual Feed Forward Control
Dual Feed Forward Control
Keiko Muro1, Takashi Nabeshima1, Terukazu Sato1, Kimihiro Nishijima1 and Shinichi Yoshida2
1 2
Oita University Renesas Technology
700 Dannoharu 5-20-1 Josuihon-cho, Kodaira
Oita 870-1192, Japan Tokyo 187-8588, Japan
nabesima@eee.oita-u.ac.jp
Abstract -- This paper presents a new control method for H- circuit topology related to the noninverting buck-boost
bridge buck-boost converter regulated by single voltage converter and their switch voltage stress are examined [1].
feedback and dual feedforward controls. This converter has two Several studies on the control method for this converter have
pairs of the switch, one acts as a synchronous buck and another
been reported but the most of them are still complicated and
as a synchronous boost operations, and therefore is suited for
battery powered applications to provide an output voltage that need a number of devices [2, 3].
is below or above the input voltage. In order to realize good This paper proposes a new control method that provides
transient performance not only with high conversion efficiency excellent stability and transient performance over the wide
but also with seamless circuitry transitions between the buck range of the input voltage with keeping higher conversion
and buck-boost regions of operation, it is proposed that the efficiency. The feedback control is only applied to the buck
voltage feedback is only applied to the buck section and the
section to obtain good stability and two feedforward controls
input voltage and the road current feedforward signals are
applied to the boost section. As a result, excellent transient are employed to the boost section to improve the transient
performances for the step load change are obtained without response in case that the input voltage is lower than the
spoiling the efficiency for wide range of the input voltage. output.
1002
PEDS2009
A. Circuit Analysis
As can be seen from the time chart of Fig. 2, there are four
states in the circuit depending on the condition of switches iL
such as duty ratios D1, D2 of the switch S1, S2 and the phase
difference φ. V:10V/div
Applying the state-space averaging method, the following iL:0.2A/div
state equation is obtained. H:500ns/div
1003
PEDS2009
ΔVo ( s ) N1
= ω vdz1 (3)
0.8
φ= 0(deg)
φ=0(deg) ΔD1 ( s ) {1 + δ s / ωo + ( s / ω o ) 2 }
φ= 250(deg)
φ=250(deg) Vi
N1 =
(1 + Z o / Rα )(1 − D2 )3α
0.7
− 2(2rs + rL ) D1
0 0.2 0.4
Io(A)
0.6 0.8 1 ωvdz1 = + (1 − D2 ) 2
R + Zo
0.8 D2=0.2
D2=0.37 ΔVo ( s ) N2
D2=0.36
D2=0.5
= ( s − ω vdz 2 ) (4)
D2=0.5
D2=0.6
ΔD2 ( s ) {1 + δ s / ωo + ( s / ωo ) 2 }
− LD1Vi
N2 =
0.7 (1 + Z o / Rα )(1 + Z o / R)(1 − D2 )4 Rα
0 0.2 0.4 0.6 0.8 1
Io(A) r − {4rs + 2rL + αrC + αR(1 − D2 )}(1 − D2 )
ωvdz 2 =
(a) Vi = 3.3V, Io = 0.3 A
L
1
It is seen form (3) that the transfer function from the duty
ratio D1 to the output voltage is obviously same with the buck
converter. From (4), on the other hand, the transfer function
from D2 has a zero in the right half plane such as boost
0.9
converter. This is confirmed from the experimental results
Efficiency
0.8 D2=0.2
D2=0.37 40 270
D2=0.5
D2=0.36 Gain
D2=0.6
D2=0.5 20 180
0 90
0.7 Phase
phase [deg]
gain [dB]
1004
PEDS2009
function from D2 shifts -180 degrees higher than the resonant Another feature of the control method proposed here is the
frequency. Therefore it is not easy to realize the excellent load current feedforward. The voltage feedback control of the
stability and dynamic performance only by controlling the buck section for the input voltage higher than the output
duty ratio D2. works well such as the conventional buck converter. Even for
the input voltage lower than the output, the transient output
voltage for small load variation is also well regulated by the
B. Control Scheme buck section. However, in case of the large variation of the
When the input voltage is higher than the output, this load condition especially from the light load to heavy one, the
converter operates as the buck one. This means the duty ratio duty ratio D1 easily reaches maximum value such as 1 due to
D2 is zero at this mode. In the region under the output voltage, the large undershoot voltage and then the transient voltage is
the converter must change its operation to the boost or buck- no longer reduced by controlling the buck section. The role of
boost mode. If the converter operates as the boost one, D1 is the load current feedforward is to reduce the transient voltage
fixed as 1 and only D2 is controlled to regulate the output. in such a case by controlling the duty ratio D2 and its function
However when the converter operates as the buck-boost only needs to work for a certain duration of the transient
mode at the input voltage near or lower than the output, both period. Therefore a high pass filter defined by the following
duty ratios can be employed as the control variable. As equation is employed in the feedforward path.
described in the preceding section, it is not preferable to use
D2 as a feedback control variable. (1 + T1 s )T2 s
This paper proposes that the duty ratio D1 is controlled by G PH = (6)
(1 + T3 s )(1 + T4 s )
the feedback signal from the output while D2 is controlled by
two feedforward signals from the input voltage and the load
C f R f R1 Cd R4
current as shown in the block diagram of Fig. 7. In the range T1 = , T2 = ( R f + R1 )
of the input voltage from slightly higher than the output to R f + R1 R1
its possible lower operating voltage, D2 is adjusted by the T3 = C f R f , T4 = Cd Rd + Cd R4
feedforward signal from the input voltage through an element R2 R3
Fv so that D1 in the steady state stays at a certain value such R4 =
R2 + R3
as 0.8 or 0.9 for example. This means that when the
maximum duty ratio of D1 in the steady state is assigned as
D1M, D2 is determined by the following equation: Cf
Vi
G PH = 1 − D1M (5) Ci Ri Rd1 Cd1
Vo
R11
For example, when D1M is chosen as 0.85, D2 becomes 0 - Vo
for the input voltage Vi higher than about 1.2 Vo and the D1 +
converter operates just as the buck mode in this case. At the
input voltage is 0.75Vo with the same condition of D1M, D2
Vr
is determined as 0.37 from (6). This function is performed by
the element Fv in Fig. 7.
(a) feedback control circuit
- + Cf
Fv GHP(s)
PWM2
Rf R1
Vi
D2 io Rd Cd
Vi - Io
H-Bridge Convertor vo
D2
+ R2
D1 Vext
Error amp R3
with phase -
feed back PWM1
feed forward compensation +
Vr
(b) feedforward control circuit
Fig. 8. Control circuit.
Fig. 7. Block diagram of proposed control scheme.
1005
PEDS2009
Fig. 8 (a) shows the feedback circuit for the buck section
and (b) is the feedforward circuit used in the experiments.
The phase compensation network is designed as the same without feedforward
way with the conventional buck converter. The resistances R1, vo
Rf and the external voltage Vext in (b) are determined by
(5).Basically the load current feedforward does not affect the
system stability but the time constant T1 should be carefully
designed to improve the transient response.
with feedforward
C. Transient Performances vo
In order to verify the effectiveness of the dual feedforward
control, the H-bridge converter shown in Fig. 1 together with
the control circuit of Fig. 8 was experimented. The transient
performances were examined by the step load change from (a) Vi=4V
0.2 A to 1 A with 3.3 V of output voltage and 0.85 of D1M.
For the input voltage variation from 4 V to 3 V, the mode
of operation changes from the buck to buck-boost in this
range, less than 20 mV of transient output voltage was without feedforward
observed. The feedforward from the input voltage to the vo
boost section enable the seamless circuitry transitions
between the buck and buck-boost regions of operation.
The transient output voltages for the step load change are
compared in Fig. 9 where the operation of the converter is (a)
the buck mode, (b) and (c) the buck-boost mode. When the
with feedforward
converter is in the buck mode, D2 = 0 in this case, less than
100 mV of the transient voltage is realized and no difference vo
of the transient voltage is observed by applying the load
current feedforward. In figures (b) and (c), on the other hand,
large undershoot voltages appear on the output, about -380
mV of the peak voltage in (c). However these large transient (b) Vi=3.3V
voltages are effectively reduced by the load current
feedforward not only for the undershoot but also for the
overshoot. The conversion efficiencies at 1 A of the load
current are 96 % in (a), 95 % in (b) and 93 % in (c), without
without feedforward
feedforward
respectively. As can be seen from these results that the dual vo
feedforward control method proposed in the paper well
improves the transient performance for the wide range of the
input voltage with keeping high efficiency.
1006
PEDS2009
REFERENCES
[1] J. Chen, D. Maksimovic, and R. Erickson, “Buck-Boost PWM
Converters Having Two Independently Controlled Switches,” PESC
2001 Record, pp.736-741, June 2001.
[2] A. A. Boora, F. Zare, G. Ledwich, and A. Ghosh, ”A Genaral
Approach to Control a Positive Buck-Boost Convertor to Achieve
Robustness against Input Voltage Fluctuation and Load Changes,”
PESC 2008 Record,pp.2011-2017.June 2008.
[3] B. Sahu and G. A. Ghosh, ”A General Approach to Control a Positive
Buck –Boost Converter to Achieve Robustness against Input Voltage
Fluctuations and Load Changes,” PESC 2008 Record,pp.2011-
2017,June 2008
1007