General Precautions
Ultra Compact Vision Sensor yyDo not use this product for the purpose to
protect a human body or a part of human
body.
Sensor head yyThis product is not intended for use as
IV-G500CA / IV-G500MA /
an explosion-proof product. Do not use
this product in hazardous location and/or
potentially explosive atmosphere.
Cautions
(1) Unauthorized reproduction of this manual in whole or
part is prohibited.
(2) The contents of this manual may be changed for
improvements without prior notice.
(3) An utmost effort has been made to ensure the contents of
this manual are as complete as possible. If there are any
mistakes or questions, please contact a KEYENCE office
listed in the back of the manual.
(4) Regardless of item (3), KEYENCE will not be liable for
any effect resulting from the use of this unit.
(5) Any manuals with missing pages or other paging faults
will be replaced.
The company names and product names used in this
manual are registered trademarks or the trademarks of their
respective companies.
1 IV-G Series (Sensor) - IM_E
yyFor instructions yyFor power supply
yyDo not turn OFF the power while setting the yyNoise superimposed on the power supply
items or saving the settings. Otherwise, all could cause malfunction. Use a stabilized
or part of the setting data may be lost. DC power supply configured with an
yyDo not let water, dust or oil stick to the isolation transformer.
camera/light of the sensor head. Failure to yyWhen using a commercially available
do so may cause a malfunction. switching regulator, be sure to ground the
yyWhen this product becomes dirty, do not frame ground terminal.
rub it with a wet cloth, benzene, thinner, or yyAttach the sensor amplifier to the DIN rail
alcohol. Doing so may change the color or then set it on the sheet metal.
shape of the unit. yyDevices including this unit are precision
yyIf the unit is heavily contaminated, components. Do not apply shock or vibration.
disconnect all the cables including the yyWhen connecting to a network, let
power supply cable, wipe off the dirt with a engineers who are knowledgeable about
cloth soaked with mild detergent, and then networks handle it.
wipe with a soft dry cloth.
yyFor external master image registration
If the external master image registration is to Precautions on Regulations and Standards
be performed frequently, set “Write ROM when
using Ext. Master Save?” of the input option UL Certification
to “No” to protect the nonvolatile memory of This product is a UL/C-UL Listed product.
the internal sensor. When the option is set to yyUL File No. E301717
“Yes”, the nonvolatile memory is guaranteed yyCategory NRKH2, NRKH8
to write for 100,000 times.
Be sure to consider the following specifications when using
yyFor automatic focus function
yyAutomatic focus function is used for this product as a UL/C-UL Listed Product.
adjusting the focusing position at the time of yyUse a power supply with Class 2 output defined in NFPA70
installation. Disabled during the operation. (NEC: National Electrical Code).
yyFocusing position can be registered in yyPower supply/External input/Control output shall be
each program. The program configurations connected to a single Class 2 source only.
are guaranteed to switch for 100,000 times. yyUse copper wire of AWG 16 to 18 (stranded wire) whose
If the focusing position does not need to temperature rating is 60°C or higher for the power terminal
be changed in each program, set “Auto block.
Focus Adjustment Position” to “Common” yyEnclosure Type 1 (Based on UL50).
to extend its duration. yyUse under pollution level 2.
yyDo not apply shock or vibration during the
focusing position adjustment. Failure to CE Marking
do so may cause a product damage.
Keyence Corporation has confirmed that this product
complies with the essential requirements of the applicable
Measures to be taken when an abnormality occurs EC Directive, based on the following specifications. Be sure
In the following cases, turn the power OFF to consider the following specifications when using this
immediately. Using the IV-G Series in an product in the Member State of European Union.
abnormal condition could cause fire, electric zz
EMC Directive
shock, or malfunction.
Contact our office for repair. yyApplicable Standard EN60947-5-2, Class A
yyIf water or debris enters the IV-G Series. yyThe length of power I/O cable and Ethernet cable must
yyIf the IV-G Series is dropped or the case is damaged. be less than or equal to 30 m.
yyIf abnormal smoke or odor emanates from Remarks:
the IV-G Series. These specifications do not give any guarantee that the
end-product with this product incorporated complies with the
Precautions on installation essential requirements of EMC Directive. The manufacturer
yyTo use this product correctly and safely, of the end-product is solely responsible for the compliance
avoid installing it in the following locations. on the end-product itself according to EMC Directive.
Failure to do so may cause fire, electric
shock, or malfunction. Checking the Package Contents
yyOutdoors
yyAltitude above 2000 m Sensor head
yyLocations that are humid, dusty or poorly
ventilated yyIV-G500CA yyIV-G500MA yyIV-G150MA
yyLocations where the temperature is high yyIV-G300CA yyIV-G600MA
such as those exposed to direct sunlight
yyLocations where there are flammable or
corrosive gases
yyLocations where the unit may be directly
subjected to vibration or i mpact
yyLocations where water, oil, or chemicals
may splash onto the unit
yyTo improve the anti-noise feature, install
the unit following the precautions below.
Otherwise, a malfunction may occur. Sensor head x 1
yyGround the FG cable of the sensor amplifier.
yyDo not mount the unit in a cabinet where high-
voltage equipment is already installed.
yyMount the unit as far from power lines as
possible.
yySeparate the unit as far as possible from the
devices that emit strong electric or magnetic
field (such as solenoid or chopper).
yySeparate the I/O signal line from the power
line or high-voltage line.
Mounting bracket x 1
Adjustable bracket for IV-G series
yyOP-87910
Mounting screw
(M4 x L8) x 2
Mounting * Double-washer
bracket x 1 sems screw Bracket x 1
3 IV-G Series (Sensor) - IM_E
Name and function of each part of the sensor
Operation of the sensor head indicator light
amplifier
IV-G10
1
5
2
Indicator light
3
yyGreen (ON).......Comprehensive result is “OK”.
yyGreen (Blink).....Under startup or setting in progress.
4 6 Operation is stopped. Blinks once a
7 second.
IV-G15 yyRed (ON)...........Comprehensive result is “NG”.
yyRed (Blink)........An error has occurred.
1 yy(OFF)................Standby status until the first judgment
finishes after starting the operation or
after switching the program number.
2
Version of the sensor head and sensor
amplifier does not match.
3 yyGreen and red ....“LED Blinking” is requested.
are blinking
5 alternately.
4
8
Operation of the sensor amplifier indicator light
1 Connector for the sensor head/amplifier cable for
IV-G series
“Cables” (Page 7) 1
2 Indicator light 2
Indicates the operating status of the sensor amplifier. 3
“Operation of the sensor amplifier indicator light” (Page 4)
3 Ethernet connector 4
Use for connecting with the intelligent monitor (IV-M30) or PC. 5
For details of connections, refer to the IV/IV-G Series User's
Manual (Monitor) or the IV/IV-G Series User's Manual (PC
Software).
When the connector is not used, attach the included LAN 1 PWR/ERR
port cap. yyGreen (ON).......Operating.
4 I/O connector yyGreen (Blink).....Setting processing. Operation is
Used for connecting the I/O cable for IV-G series stopped. Blinks once a second.
(OP-87906). yyRed (ON)...........Unrecoverable error has occurred.
yyRed (Blink)........Recoverable error has occurred.
5 IP reset switch
yy(OFF)................Power is not supplied.
Used for resetting the IP address assigned to this sensor
amplifier. 2 OUT
For details, refer to the IV/IV-G Series User's Manual Indicates the comprehensive result.
(Monitor) or the IV/IV-G Series User's Manual (PC yyGreen................Comprehensive result is “OK”.
Software). yyRed...................Comprehensive result is “NG”.
yy(OFF)................Setting processing.
6 Add-on connector Standby status until the first judge
Used for adding the IV-G15 (Expansion). finishes after starting the operation or
“Mounting the Sensor Amplifier” (Page 6) after switching the program number.
Protection sheet is attached for shipping.
3 TRIG
7 Power terminal block Green light lights up (one-shot) according to input of the
Supplies power to the IV-G10. This is not equipped with internal or external trigger.
the IV-G15.
4 STATUS
8 Add-on connector Indicates the connection status within the monitor.
Used for connecting the IV-G10 (Main). yyGreen (ON).......Normally connected with monitor or PC.
yyGreen (Blink).....IP address has been retrieved but
the sensor amplifier is not correctly
connected with monitor or PC.
yyRed (ON)...........The IP address coincides with other
device or a network loop is detected.
yy(OFF)................IP address is not assigned. Sensor
amplifier is not correctly connected with
monitor or PC.
5 LINK/ACT
Indicates the linking status within monitor or Ethernet switch.
yyGreen (ON).......Normally linked.
yyGreen (Blink).....Normally linked, and the data is
sending/receiving.
yy(OFF)................Sensor amplifier is not normally linked.
Indicator light
View V
Installed distance WD
When screws are secured from the wall
yyScrew : M4 x 2
yyTightening torque : 0.7 to 1.5N·m
View V = View H x 0.75
yyScrew hole on the sensor head: M4 female (whose
(H :V = 4 :3)
length of screw engagement should be 2.5 to 3.5 mm)
zz
IV-G150MA
Installed distance View View
WD (mm) H (mm) V (mm)
40 8 6
50 11 8
100 22 16
150 34 24
zz
IV-G500CA / IV-G500MA
Installed distance View View
WD (mm) H (mm) V (mm)
20 10 7.5
50 20 15
100 40 30
200 80 60
300 120 90
400 160 120
500 200 150
When using the transverse mounting bracket
for IV-G series (OP-87909)
Attach the bracket using the screws attached to OP-87909.
yyTightening torque : 0.7 to 1.5N·m
Mounting
examples
Stopper
Convex part
Protection seal
IV-G15 (Expansion)
Cables
Connecting the Ethernet cable or LAN cable
Connect the cable to the sensor amplifier as shown
below.
can be set.
A2 Red IN2 OFF A1 B1 B10 A10
Input assignable
A3 Orange IN3 OFF function
yyProgram bit0 to bit4 B1 A1
A4 Yellow IN4 OFF
yyClear Error
A5 Green IN5 OFF yyExt. Master Save
yyOFF (not used)
A6 Blue IN6 OFF
A7 Purple Unused Unused
A8 Gray Unused Unused Pin No. Color Pin No. Color
Unused
A9 White Unused Unused B10 Black A10 Black
A10 Black Unused Unused B9 White A9 White
B8 Gray A8 Gray
B7 Purple A7 Purple
B6 Blue A6 Blue
B5 Green A5 Green
B4 Yellow A4 Yellow
B3 Orange A3 Orange
B2 Red A2 Red
B1 Brown A1 Brown
yy24 V : Supplies 24 V DC
yy0 V : Wire to 0 V of the power supply. * For the terminal number and wiring color, refer to
yyFG : Ground
“●Terminal number and wiring color of the I/O
Follow the instructions given below to avoid
cable for IV-G series (OP-87906)” (Page 8).
damage caused by bad connections.
yyThe nominal cross-sectional area of the
wire for connecting the power should be
0.8mm2 to 1.3mm2 (AWG 16 to 18).
yyLength of removing insulation from the wire
should be about 9 mm.
yyThe stripped part of the wire should not be
soldered (pre-soldered).
yyInsert the wires into the power terminal
block all the way.
yyConnect the wires directly. Do not use a
crimp-type terminal.
+3.3V Brown
Load
Overcurrent protection circuit
Main circuit
Main circuit
* *
0V 0V
* Refer to “●Terminal number and wiring color of the I/O * Refer to “●Terminal number and wiring color of the I/O
cable for IV-G series (OP-87906)” (Page 8). cable for IV-G series (OP-87906)” (Page 8).
Use by assigning the optional functions to IN2 to 6 Use by assigning the optional functions to OUT1 to OUT8
Voltage input
When the PNP output is selected
(When the PNP output is selected) When PNP is selected in I/O format, the circuit becomes
open collector PNP output circuit.
When PNP is selected in I/O format, the circuit becomes
voltage input circuit. yyRemaining voltage : 1.5 V or lower
yyMaximum rating : 26.4 V, 50 mA
yyInput maximum rating : 26.4 V
(20 mA when the
yyON voltage : 18 V or higher
IV-G15 (Expansion) is
yyON current : 2 mA (for 24 V)
connected)
yyOFF current : 0.2 mA or lower
yyRemaining voltage : 2 V or lower
DC24V
DC24V
Overcurrent protection circuit
Main circuit
Main circuit
IN1 - IN6
OUT1 - OUT8
*
*
Load
0V
0V
IV-G15 (Expansion)
Sensor Head
IV-G500CA / IV-G500MA / IV-G150MA / IV-G300CA / IV-G600MA
61.1
(32.6)
30.3 57.2
2.9 Indicator
12
90
93.8
17.4
(44.3)
38.1
44.3
46.3
51.8
(104.7)
Center of light reception
38.4±1.2
(31)
φ12
17.9
24
29.6
35.6
(31)
φ4.8
44.3
Minimum 137.8
When using an Ethernet cable
Minimum
Minimum 118.6
20
49.8
Sensor Amplifier
IV-G10 (Main)
90
(104.7)
54.9
61.1 LAN cable I/O cable for IV-G series
or
30.3 57.2 Ethernet cable
Sensor head/amplifier cable
for IV-G series
φ 4.8
Minimum 137.8
When using an Ethernet cable
Minimum 118.6
When using a LAN cable
36.8
30.3 61.8
Sensor head/
amplifier cable
DIN rail for IV-G series
49.8
LAN cable
or
Ethernet cable
54.9
Sensor Amplifier
Model IV-G10 (Main) IV-G15 (Expansion)
Type Outline, Color area*4, Area*5, Position adjustment
Tool
Number*6 Detection tools : 16 tools, Position adjustment tool : 1 tool
Switch settings
32 programs
(programs)
Number of
Image Color-type head: 100 images*8, monochrome-type head: 300 images*9
cases
history*7
Condition NG only/All is selectable
OFF/Statistics/Histogram is switchable
Statistics : Processing time (latest value, MAX, MIN, AVE), numbers of OKs, numbers of NGs,
Analysis information*10 trigger numbers, trigger errors, judge results list by tools
Histogram : Histogram, matching degree (latest value, MAX, MIN, AVE), numbers of OKs,
numbers of NGs
HDR, High Gain, Color Filters*4, Digital Zoom (x2, x4)*11, Brightness Correction,Tilt correction,
White balance*4, Mask outline, Mask area, Test run, ToolAutoTune, Input monitor, Output test,
Other functions
Security settings, Simulator, Prevention function for mutual interference among heads,
Total status output, Direct connection (2 units or more), List of NG Sensor Occurrences, NG Hold Function
Indicators PWR/ERR, OUT, TRIG, STATUS, LINK/ACT
No-voltage input/voltage input is switchable
For no-voltage input : ON voltage 2 V or lower, OFF current 0.1 mA or lower,
Input ON current 2 mA (short circuit)
For voltage input : Maximum input rating 26.4 V, ON voltage 18 V or higher,
OFF current 0.2 mA or lower, ON current 2 mA (for 24 V)
Inputs 6 inputs (IN1 to IN6)
IN1 : External trigger, IN2 to IN6 : Enable by assigning the optional functions
Function Assignable functions : Program switching, Clear error, External master image registration,
Main/Expansion simultaneous input
*1 The focusing position can be automatically adjusted at the time of installation. Disabled during the operation. The focusing
position can be registered by programs.
*2 Except when the dome attachment (IV-GD05/IV-GD10) is mounted.
*3 Except when the polarizing filter attachment (OP-87899/OP-87900/OP-87901/OP-87902) is mounted.
*4 Color type only.
*5 Monochrome type only.
*6 Tools can be installed by programs.
*7 Saves to the memory in the sensor. The images saved in the sensor can be backed up to the USB memory installed to the
intelligent monitor (IV-M30) or to the PC by the PC Software for IV/IV-G series (IV-H1).
*8 70 images when using the FTP client function.
*9 210 images when using the FTP client function.
*10 This can be displayed on the intelligent monitor (IV-M30) or by the PC Software for IV/IV-G series (IV-H1).
*11 Color type and monochrome type.
*12 This is for connection with the intelligent monitor (IV-M30) or the PC Software for IV-IV-G Series(IV-H1).
*13 Mount to the DIN rail, then set them on the sheet metal.
E 1101-3