MO DE L : S P R- 2 3 0 NE - B L K- D
Panel Efficiency η
Current (A)
18.5 % 800 W/m²
Grounding Positive grounding not required 113 psf 550 kg/m² (5400 Pa), front (e.g. snow)
Max load
w/specified mounting configurations
Frame Anodized aluminum alloy type 6063 (black) 10-year limited product warranty
4 3 2 1
Weight 33.1 lbs. (15.0 kg) Certifications Tested to UL 1703. Class C Fire Rating
D
DIMENSIONS D
C (B) C
2X 199.5 7.85
798 31.42
2X 200 7.85
754 29.69
(B)
BOTH
ENDS
Please read safety and installation instructions before using this product, visit sunpowercorp.com
for more details. UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN MM 3939 NORTH FIRST STREET
SAN JOSE, CA 95134 USA
sunpowercorp.com
TOLERANCES ARE:
DECIMALS ANGLES (408) 240-5500
© 2012 SunPower Corporation. SUNPOWER, the SunPower Logo, and THE WORLD’S STANDARD FOR SOLAR, and MAXEON are trademarks or registered trademarks
of SunPower Corporation in the US and other countries as well. All Rights Reserved. Specifications included in this datasheet are subject to change without notice.
THIS DOCUMENT CONTAINS PROPRIETARY Document #501420 Rev A / LTR_EN
INFORMATION OF THE SUNPOWER
CORPORATION, AND ITS RECEIPT OR
CS 12_139
A POSSESSION DOES NOT CONVEY ANY RIGHTS
MPPT 96%
Charging 17 Vmp
94%
92%
Efficiency (%)
Non-MPPT PV I-V
Current
Charging Curve
90%
88%
BATTERY 86%
S
TT VOLTAGE
WA RANGE 84%
82%
80%
10 15V ~17V 0 25 50 75 100 125 150 175 200
Voltage Output Power (Watts)
TECHNICAL SPECIFICATIONS
Electrical Battery Charging
• Peak Efficiency 97.5% • Battery Types Gel, Sealed, AGM, Flooded
• Nominal Battery Voltage 12 or 24 volts • 4 Stage Charging Bulk, absorption, float, equalize
• Maximum Battery Charging Current 15 amps (optional)
• Battery Voltage Range 7-36 volts • Temperature Compensation
Coefficient –5mV/°C / cell (25°C ref)
• Nominal Maximum Operating Power*
Range –30°C to +60°C
12 volt battery 200 Watts Set points Absorption, float, equalize
24 volt battery 400 Watts
• Maximum PV Open Circuit Voltage** 60 volts Mechanical
• Rated Load Current 15 amps • Dimensions 16.9h x 6.4w x 7.3d cm
• Self Consumption 35 milliamps 6.6h x 2.5w x 2.9d in
• Transient Surge Protection 4 x 1500 Watts • Weight 0.60 kg / 1.3 lbs
• Power Terminal 16 mm2 / #6 AWG
Environmental • Enclosure Die cast aluminum with plastic cover
• Operating Temperature –40°C to +60°C
• Storage Temperature –55°C to +100°C Options
• Humidity 100%, non-condensing • Remote Meter
• Tropicalization Epoxy encapsulation Conformal • Remote Temperature Sensor
coating Marine rated terminals • USB MeterBus Adapter (UMC-1)
• PC MeterBus Adapter for RS-232
Electronic Protections • DIN Rail Mounting Clips
• PV: Overload, Short Circuit, High Voltage
• Load: Overload, Short Circuit
Certifications
• Reverse Polarity: Battery, PV and Load • CE Compliant
• Lightning and Transient Surges • RoHS Compliant
• High Temperature • UL 1741 / CSA 107.1-01 recognized component
• Reverse Current at Night • Manufactured in a Certified ISO 9001 Facility
*Input power can exceed Nominal Maximum Operating Power, but controller will
limit and provide its rated continuous maximum output current into batteries. This
will not harm the controller (reminder: do not exceed Voc).
**Exceeding Maximum PV Open Circuit Voltage may damage the controller.
www.morningstarcorp.com
© 2017 MORNINGSTAR CORPORATION
8924-WR
High Output
90+CRI
5.6W /ft.
8024/8924 SERIES
Input Power (W) 5.48 5.65 5.47 5.27 5.29 5.36 5.56
Efficacy 61 69 68 74 79 82 80
Input Current (AMP) 0.23 0.24 0.23 0.22 0.22 0.22 0.23
Correlated Color Temperature 2150 2350 2550 2650 2950 3450 3950
E348513
Component of a complete system including: Aion LED A-Track Light Engine, Aion LED A-Track housing with diffuser lens, & Aion LED driver (power supply).
Dimmer not included. Approved dimmers, controls, power supplies, cable, & other components only. Contact Aion LED for questions regarding compatibility.
Electrician installed. Strictly adhere to NEC & local building code. Limited 5-year warranty against manufacturing defects only, does not cover labor; voided by:
AIONLED.COM | (415) 255-AION
inadequate ventilation, field modifications, installation by unqualified personnel, unapproved controls, drivers, cabling, other devices, not following installation
guidelines & protocol, general negligence. Installer assumes all liability with regard to property & safety. This product is UL listed. See separate “Aion LED PAGE 3 | MODIFIED June 12, 2017
Warranty Terms” & additional instructional materials for more information. Authorized installers only. Systems tested prior to shipping. © 2017 Aion LED. All Rights Reserved
8G30H-DEKA
Valve-Regulated, Gelled-Electrolyte Battery
SPECIFICATIONS
Nominal Voltage (V) 12V
Container/Cover Polypropylene
Terminal B (T876)
Distributed by:
MK Battery
1631 South Sinclair Street ● Anaheim, California 92806
Toll Free: 800-372-9253 ● Fax: 714-937-0818 ● E-mail: sales@mkbattery.com
All data subject to change without notice. No part of this document may be copied or reproduced, electronically or mechanically, without written permission from the company. ©2017 MK Battery