Beam span L=3.75 m
Section comprises steel plates to top & bottom faces of timber.
bs
ÃÄÄÄ´
ÚÄÄÄ¿ ÄÂÄ ds
Section design parameters ÚÁÄÄÄÁ¿ ÄÅÄ
ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ³ ³ ³
x Äù³ ³ùÄ x d
³ ³ ³
ÀÂÄÄÄÂÙ ÄÅÄ
ÀÄÄÄÙ ÄÁÄ ds
ÃÄÄbÄÄ´
Modification factors
ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
Duration of loading K3=1.25
Depth factor K7=(300/d)^0.11=(300/195)^0.11
=1.0485
Bending
ÄÄÄÄÄÄÄ
Strains in the timber and steel are the same at the same distance
from the neutral axis. Since Ys > Yt ( 107.5 mm > 97.5 mm ) the
stress in
the timber will be less than that of the modified steel as a ratio of
the distances Ys and Yt.
Applied bending stress in steel sigmas=MR*M/Zc
=44.181*5.2734E6/9.2175E6
=25.276 N/mm2
28 Juniper Road Page: 4
Flitch Beam Made by: Alok
GL1 Date: 01.08.18
Kashec Ref No: K2002
ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
Office: 1022
Applied bending stress in timber sigmat=sigmas*Yn/Yc/MR
=25.276*97.5/107.5/44.181
=0.51889 N/mm2
Since sigmat <= sigmad ( 0.51889 N/mm <=5.5572 N/mm2 ) applied
2
Shear
ÄÄÄÄÄ
No notches to occur at the critical shear position.
Permissible shear force on timber tortp= 2*torad*b*d/3
= 2*0.75375*100*195/3
=9798.8 N
Since Fve <= tortp ( 5625 N <=9798.8 N ) shear capacity of
timber alone is greater than applied shear force, therefore OK.
Bearing
ÄÄÄÄÄÄÄ
Timber bearing stress on support sigba=Fve/(lb*b)=5625/(150*100)
=0.375 N/mm2
Since sigba <= sigbad ( 0.375 N/mm <=1.65 N/mm2 ) bearing stress
2
For loading parallel to the grain, the spacing across the grain
between bolts or rows of bolts should be not less than 80 mm.
Max No of rows of 20 mm dia bolts NR=INT(1+((b/bd-3)/4))
=INT(1+((100/20-3)/4))
=1
No of rows of bolts to be adopted NRC=1
The distance from the end of the timber to the centre of the nearest
bolt hole for parallel to the grain loading should be not less than
80 mm where the bolts are bearing away from the end of the member,
or 140 mm where bolts are bearing towards the end of the member.
The bolt spacing in the direction of load should be not less than
80 mm.
Equations G1 G2 G3 G4 G5 G6
48360 48360 26041 19836 19836 15181
Minimum value of equations G1 to G6 Gmin=15181
No256