Download as pdf or txt
Download as pdf or txt
You are on page 1of 59

Product Submittal

MasterSeal® AWB 661I


Air and Water-Resistive Barrier Membrane –
meeting Class A requirements of ASTM E84 Surface Burning test
Index
1. Company profile

2. Commercial Licenses

3. I SO Certificates - Quality, Environment & Safety Certificates

4. Civil Defence Certificate

5. DCL Certificate

6. Technical datasheets:

7. Method statements

• Application on concrete or block work

• Application on framing and sheathing boards

8. Job references

9. Approvals

10. Test reports


Company Profile
About BASF
At BASF, we create chemistry for a sustainable future. We
combine economic success with environmental protection and
social responsibility. The approximately 114,000 employees in the
BASF Group work on contributing to the success of our customers
in nearly all sectors and almost every country in the world. Our
portfolio is organized into five segments: Chemicals, Performance
Products, Functional Materials & Solutions, Agricultural Solutions
and Oil & Gas.
BASF generated sales of about €58 billion in 2016.
BASF shares are traded on the stock exchanges in Frankfurt (BAS), London (BFA) and Zurich (BAS). Further information
at www.basf.com.

About the Construction Chemicals Division


BASF’s Construction Chemicals division offers advanced
chemicals solutions for new construction, maintenance, repair and
renovation of structures. As a leading provider of raw materials,
systems and finish products to the construction industry, BASF
provides economically and ecologically sound solutions that
facilitate high-quality construction. BASF materials and solutions
increase resource and energy efficiency and improve building life
expectancy, thus also lowering expenditure on maintenance and
repairs.

As a reliable partner for our customers we deliver innovative, customized and easy-to-use solutions for sustainable
construction. The division operates production sites and sales centers in more than 60 countries and achieved sales of
about €2.3 billion in 2016.
Master Builders Solutions
Master Builders Solutions is BASF’s brand of advanced
chemical solutions for construction. The Master Builders
Solutions brand is built on the experience gained from more
than 100 years in the construction industry. The
comprehensive portfolio under the Master Builders
Solutions brand encompasses lasting solutions for new
construction, maintenance, repair and renovation of
structures: Concrete admixtures, cement additives,
chemical solutions for underground construction,
waterproofing solutions, sealants, repair & protection
solutions, performance grouts, tiling solutions and performance flooring solutions.

The Master Builders Solutions brand is backed by a global community of BASF construction experts. To solve our
customers’ specific construction challenges from conception through to completion a project, we combine our know-
how across areas of expertise and regions and draw on the experience gained in countless construction projects
worldwide. We leverage global BASF technologies, as well as our in-depth knowledge of local building needs, to
develop innovations that help make our customers more successful and drive sustainable construction. For more
information please visit www.master-builders-solutions.basf.ae

Master Builders Solutions from BASF for the Construction Industry


MasterAir® MasterGlenium® MasterSeal®
Complete solutions for air entrained Solutions for hyperplasticized concrete Solutions for waterproofing and
concrete sealing
MasterInject®
MasterBrace® Solutions for concrete injection MasterSet®
Solutions for strengthening and structural Solutions for set control
MasterKure®
adhesives
Solutions for concrete curing MasterSure®
MasterCast®
Solutions for the manufactured concrete MasterLife ® Solutions for extraordinary workability
product industry Solutions for enhanced durability retention

MasterCem® MasterMatrix® MasterTile®


Solutions for cement manufacture Advanced rheology control solutions Solutions for tile fixing system
MasterEase ®
MasterPolyheed® MasterTop®
Solutions for low viscosity concrete High-performance superplasticizer Solutions for industrial and commercial
MasterEmaco® floors
MasterPozzolith ®
Solutions for concrete repair
Solutions for water-reduced concrete MasterWeld®
MasterFinish®
MasterProtect ® Adhesive solutions for construction
Solutions for formwork treatment
Solutions for concrete protection
MasterFlow® Master X-Seed®
Solutions for precision grouting MasterRheobuild ®
Advanced accelerator solutions for
Superplasticizer for concrete concrete
MasterFiber ®

Comprehensive solutions for fiber MasterRoc® Ucrete®


reinforced concrete Solutions for underground construction Flooring solutions for harsh environments

International Accreditation
BASF Construction Chemicals UAE LLC is a registered GCC manufacturer certified
to the ISO 9001 Quality Management System, Environmental Standard ISO 14001
and the Occupational Health & Safety Standard OHSAS 18001.

® = Registered trademark of the BASF-Group in many countries


Commercial Licenses
‫رخصة صناعية‬
Industrial License
License Details / ‫تفاصيل الرخصة‬
License No. ‫رقم الرخصة‬
511017
)‫بي ايه اس اف لكيماويات البناء اع م (ش ذ م م‬ ‫اسم الشركة‬

Company Name BASF CONSTRUCTION CHEMICALS UAE )L.L.C(


(‫بي ايه اس اف لكيماويات البناء اع م )ش ذ م م‬ ‫السم التجارى‬
Trade Name BASF CONSTRUCTION CHEMICALS UAE (L.L.C)

Legal Type Limited Liability Company)LLC( ‫ذات مسئولية محدودة‬ ‫الشكل القانونى‬
Expiry Date 21/03/2019 ‫تاريخ النتهاء‬ Issue Date 22/03/1999 ‫تاريخ الصدار‬
D&B D-U-N-S ® No. 366717796 ‫الرقم العالمي‬ Main License No. 511017 ‫رقم الرخصة الم‬
Register No. 52538 ‫رقم السجل التجارى‬ DCCI No. 53865 ‫عضوية الغرفة‬

License Members / ‫اطراف الرخصة‬


Share / ‫الحصص‬ Role /‫الصفة‬ Nationality / ‫الجنسية‬ No./‫رقم الشخص‬ Name / ‫السم‬
Manager / ‫مدير‬ United Kingdom / ‫بريطانيا‬ 587758 PAUL HAMLETT / ‫باول هامليت‬
Manager / ‫مدير‬ Czech Republic / ‫جمهورية‬ 587759 ONDREJ NEMECEK / ‫اوندريج نميسك‬
‫التشيك‬
Manager / ‫مدير‬ Germany / ‫المانيا‬ 587757 CHRISTIAN DANIEL GEIERHAAS / ‫كريستيان دانيل‬
‫جايرهاز‬

License Activities / ‫نشاط الرخصة التجارية‬


Construction Chemicals Manufacturing ‫صناعة المواد الكيماوية لغراض البناء‬
Fire Resistant & Retardant Materials Manufacturing ‫صناعة المواد المقاومة والمانعة لنتشار الحريق‬
Fire Resistant & Retardant Materials Trading ‫تجارة المواد المقاومة والمانعة لنتشار الحريق‬
Basic Industrial Chemicals Trading ‫تجارة الكيماويات الصناعية الساسية‬
Construction Chemicals Trading ‫تجارة المواد الكيماوية لغراض البناء‬

Address / ‫العنوان‬
Telephone 971-4-8851000 ‫تليفون‬ P.O. Box 37127 ‫صندوق البريد‬
Fax 971-4-8851130 ‫فاكس‬ Parcel ID 598-387 ‫رقم القطعة‬
Mobile No 971-50-1501570 ‫الهاتف المتحرك‬ ‫ منطقة جبل على الصناعية‬- ‫مصنع ملك مجمع دبي للستثمار‬

Remarks / ‫الملحظات‬
2015-9-2 ‫تم تغيير المدير‬

Print Date 26/03/2018 9:22 ‫تاريخ الطباعة‬ Receipt No. 12856729 ‫رقم اليصال‬

.‫اتصالت) للحصول على اذن الدفع‬/‫ (دو‬6969 ‫ أرسل رقم الرخصة إلى‬،‫يمكنك الن تجديد رخصتك التجارية من خلل الرسائل النصية القصيرة‬
Now you can renew your trade license by sending a text message )SMS(. Send your trade license number to 6969 )Du/ Etisalat( to receive payment

www.dubaided.gov.ae ‫لمراجعة صحة البيانات الواردة في الرخصة برجاء زيارة الموقع‬. ‫وثيقة إلكترونية معتمدة وصادرة بدون توقيع من دائرة التنمية القتصادية‬
Approved electronic document issued without signature by the Department of Economic Development. To verify the license kindly visit
www.dubaided.gov.ae
‫ملحق الشركاء‬
Partners
License Details / ‫تفاصيل الرخصة‬
D&B D-U-N-S ® ‫ الرقم العالمي‬License No. ‫رقم الرخصة‬
366717796 511017
No.

License Partners / ‫اصحاب الرخصة‬


Sr. No./‫مسلسل الشخص‬ Nationality / ‫الجنسية‬ Name / ‫السم‬
51.0000000% 435719 ‫ المارات‬/ United Arab Emirates ‫ القرن للستثمار ذ م م‬/ CENTURY INVESTMENT LLC
49.0000000% 435716 ‫ بريطانيا‬/ United Kingdom BASF CONSTRUCTION CHEMICALS UK LIMITED
‫ بي ايه اس اف كونستركشن كيميكالز يو كيه ليمتد‬/

Print Date 26/03/2018 9:22 ‫تاريخ الطباعة‬ Receipt No. 12856729 ‫رقم اليصال‬

.‫اتصالت) للحصول على اذن الدفع‬/‫ (دو‬6969 ‫ أرسل رقم الرخصة إلى‬،‫يمكنك الن تجديد رخصتك التجارية من خلل الرسائل النصية القصيرة‬
Now you can renew your trade license by sending a text message )SMS(. Send your trade license number to 6969 )Du/ Etisalat( to receive payment

www.dubaided.gov.ae ‫لمراجعة صحة البيانات الواردة في الرخصة برجاء زيارة الموقع‬. ‫وثيقة إلكترونية معتمدة وصادرة بدون توقيع من دائرة التنمية القتصادية‬
Approved electronic document issued without signature by the Department of Economic Development. To verify the license kindly visit
www.dubaided.gov.ae
ISO Certificates – Quality,
Environment & Safety Certificates
Civil Defence Certificate
DCL Certificate
CERTIFICATE OF PRODUCT CONFORMITY
Dubai Central Laboratory Department (DCLD) of Dubai Municipality,
hereby attests that the product(s)
LOW EMMITING MATERIALS (COATINGS, SEALANT AND ADHESIVE)

BASF CONSTRUCTION CHEMICALS UAE L.L.C


P. O. Box: 37127, Dubai Investments Park, Dubai, United Arab Emirates

have been assessed in accordance with DCLD Document Ref. No. RD-DP21-2001 (IC) “General Rules for DM third party product certification system
through factory assessment” and the relevant Specific Rules, and were found in conformity with the standard specification:

2010 Dubai Green Building Regulations and Specifications


Accordingly, DCLD hereby authorizes the above manufacturer
to affix the DCL Product Conformity Mark to the above-mentioned product(s).

for / ENGR. AMIN AHMED AMIN


Director, Dubai Central Laboratory Department
Dubai Municipality
Verify:

Certificate No: CL17020503 Current Issue Date: 17 September 2017


Valid Until: 16 September 2018 Original Issue Date: 17 September 2017

F-IC-2031 REV 11
The attached Scope of Certification bearing the same Certificate No. forms an integral part of this Certificate.
This Certificate is an electronic document, subject to the Terms and Conditions of the Product Certification System and shall not be reproduced except in full.
DUBAI CENTRAL LABORATORY DEPARTMENT
DCL PRODUCT CONFORMITY CERTIFICATION SCHEME

SCOPE OF CERTIFICATION
FOR CERTIFICATE NO. CL17020503 Rev 01

Certificate Issued To: BASF CONSTRUCTION CHEMICALS UAE L.L.C


P. O. Box: 37127, Dubai Investments Park,
Dubai, United Arab Emirates

Applicable Standard Specification: 2010 Dubai Green Building Regulations and


Specifications (GBRS)

Applicable Specific Rules: RD-DP21-2180-(IC) Specific Rules for


Certification of Paints and Coating through
Factory Assessment as per the 2010 Dubai
Green Building Regulations and
Specifications.
1- Coatings

Product
S/N Brand Name Product Details
Description
Solvent Base Coating
for Interior & Exterior coatings
products
Exterior walls of VOC (GBRS limit is max.430 g/l)
1 mineral SRI =78 (min) {SRI Class 1 as per
MasterProtect 300
substrate Annex B of RD-DP21-2180(IC)}
coatings (3)
LRV Class 1 (=>45) – “Can be used in
75-100% of surface to be
/painted/coated”

Water Base Coating


for Interior & Exterior coatings
products
Exterior walls of
mineral Masterseal AWB661 I VOC (GBRS limit is max.430 g/l)
2*
substrate Masterseal AWB661 HP SRI =78 (min) {SRI Class 1 as per
coatings (3) Annex B of RD-DP21-2180(IC)}
LRV Class 2 (<45) – “Can be used in
0-25% of surface to be

F-IC-2032 R6
P.O. Box 67, DCL, Zabeel Road, Karama, Dubai, UAE
DUBAI CENTRAL LABORATORY DEPARTMENT
DCL PRODUCT CONFORMITY CERTIFICATION SCHEME

SCOPE OF CERTIFICATION
FOR CERTIFICATE NO. CL17020503 Rev 01

NOTE1: This document forms part of the Certificate of Product Conformity bearing the same
certificate number.
NOTE2: The above product shall bear the DCL Conformity Mark.

NOTE3: * New added products to the scope of certification

NOTE 4: This scope supersede previous scope issued on 17 Sep 2017

Original Issue Date : 17 September 2017


Current Issue Date : 19 December 2017
Valid Until : 16 September 2018

ARIF HUSAIN AL MARZOOQI


Head of Products Conformity Assessment Section
Dubai Central Laboratory Department

F-IC-2032 R6
P.O. Box 67, DCL, Zabeel Road, Karama, Dubai, UAE
Technical Data sheet
MasterSeal® AWB 661I
Air and Water-Resistive Barrier Membrane - meeting Class A requirements of ASTM E84 Surface
Burning test

DESCRIPTION  One component, low-VOC formulation -


MasterSeal AWB 661I is a one-component Easy to apply, meets statutory VOC
liquid applied air/water-resistive barrier that can requirements.
also function as a vapor retarder. It is based on  Non-flammable – improves workplace
Silica Fortified Rubber™ chemistry. It is safety.
chemically identical to, and performs the same  Mineral oil and plasticizer free - will not dry
function as, Enershield I, which is replaces. out or crack.
This waterproof, resilient membrane may be  Water based – clean tools with water.
spray-, roller-, or brush- applied directly to  Approved for use with BASF EIFS and
approved above grade wall substrates. It stucco systems - full system warranty,
provides excellent secondary moisture seamless membrane for buildings with
protection behind most wall claddings including multiple claddings.
brick, siding, metal panels, and EIFS.  Can be left exposed for 120 days – allows
flexible construction scheduling.
PRIMARY USES
As a very low permeability, air, vapor and water PACKAGING
barrier for high rise and low rise residential, MasterSeal AWB 661I is available in 25kg
commercial, institutional buildings. pails.
As an integral part of building designs to reduce
heating and cooling costs during the life of the COLOR
building. Grey and Reddish brown
For use over the following above ground,
COVERAGE
exterior wall substrates:
 In-situ concrete Depends on substrate and degree of
 Precast concrete preparation:
 Concrete blocks
Poured Concrete Approx. 23.5m² per pail
o Aerated
Concrete Masonry Units Approx. 18m² per pail
o Hollow (CMU)*
o Solid Concrete / Masonry pre- Approx. 24.5m² per pail
 Cement board treated and smoothed with
MasterSeal AWB 661FL
ADVANTAGES Block Filler
Cement Board Approx. 23.5m² per pail
 Meets Class A classification of surface
flame spread according to ASTM E 84
*Above figures refer to application by roller or
 Exhibits 0.01%l/s/m² air permeance spray and back-roll method for optimum
according to ASTM E2178 - easily meets air coverage rate. Other application methods may
permeance of Building Materials ASTM provide less coverage. Actual results may vary
E2178. depending on surface porosity, moisture uptake
 Meets ASTM D1970 nail sealability or other factors.
requirements with and without Sheathing
Fabric - Self-sealing performance.
 Tough, abrasion resistant membrane when
cured - rugged resists damage by following
trades after installation.
MasterSeal® AWB 661I

TYPICAL PROPERTIES

Test Results
Solids Content 74%
VOC Content - ASTM D2369 (EPA method 24 part) 4g/l
Surface Burning - ASTM E84 @ coating thickness ±600 Class A Flame Spread Index (<25)
microns Class A Smoke Developed Index (<450)
Fire Resistance E119/UL263 Has been shown not to add or detract from the rating of
a fire resistive wall assembly
Air Permeance of Building Materials - ASTM E2178 0.01 l/s.m² @ 75 Pa
Water Vapor Transmission - ASTM E96 Method B <1.0 Perms (grains/Hr.) @ 0.5mm wet film thickness
Pull-Off Strength - ASTM D4541-2002 1.0N/mm²
Multi-Story Fire Tests - NFPA 285 Passed using BASF EIFS System
Water permeability BS EN 12390 Nil
Drainage efficiency ASTM E2273 >90%

SURFACE PREPARATION Application: pretreatment of rough openings


Substrates must be dry, clean, sound and free and joins in cement boards
of curing compounds, release agents, paint or
other residue or contamination. All rough openings such as window openings
Surface irregularities in concrete, block or brick should be fully pretreated with
work should be pretreated with MasterSeal AWB 661I.
MasterSeal AWB 661FL (see Product Data
Sheet) to provide a smooth surface and ensure If applying to cement fiber boards or similar, all
a void and pinhole free membrane. joints should be pretreated with reinforcing
fabric embedded in MasterSeal AWB 661I.
MIXING
For full details see Method Statement.
MasterSeal AWB 661I is supplied as a single
component material which can be used directly
from original packaging or poured into a new APPLICATION
container that is clean and free of foreign If using roller, brush, or trowel application, allow
substances. It should be thoroughly stirred with any previously applied materials to board joints
a clean, rust-free drill and paddle until or rough openings to dry to the touch before
homogeneous. applying MasterSeal AWB 661I to entire wall
Never dilute MasterSeal AWB 661I. surface. If spraying, “wet on wet” application is
Close container when not in use. acceptable.

APPLICATION If applying by roller, it is necessary to pre-wet


the synthetic roller pad with water and spin out
Application Equipment the excess water. The pre-wetting only needs to
Use a 20mm nap roller or paint brush. be done once at the start of application.
If spraying, refer to Method Statement for Apply first coat to a uniform wet film thickness of
MasterSeal AWB 661I / 300 - 325 microns. Allow to dry and check for
MasterSeal AWB 661HP / blisters and to ensure the coating is void and
MasterSeal AWB 661FL for details of spray pinhole free. Apply second coat at 300 - 325
application equipment and application microns wet film thickness.
instructions.
MasterSeal® AWB 661I
35°C. Protect from extreme heat and direct
When spraying a single coat of 600 - 650 sunlight. Do not stack pallets.
microns wet fil thickness can be applied but only
on cement boards meeting ASTM C1177 Shelf life
standard or on concrete masonry substrates Approximately 12 months when stored as
that have first been pretreated with a scrape above.
coat of MasterSeal AWB 661FL.
SAFETY PRECAUTIONS
Allow to dry completely. Drying time 2-4 hours As with all chemical products, care should be
@ 20°C taken during use and storage to avoid contact
with eyes mouth, skin and foodstuffs. Treat
Clean tools and equipment with water splashes to eyes and skin immediately. If
immediately after use. Dried material can only accidentally ingested, seek immediate medical
be removed mechanically. attention. Keep away from children & animals.
Reseal containers after use. For further
Application temperatures information, refer to material safety data sheet.
MasterSeal AWB 661I can be applied from
+5°C to 40°C
NOTE
Field service, where provided, does not
WATCHPOINTS
constitute supervisory responsibility. For
Protect from rain until completely cured. additional information contact your local BASF
representative.
Do not use MasterSeal AWB 661I for below- BASF reserves the right to have the true cause
grade applications or on surfaces subject to of any difficulty determined by accepted test
water immersion. methods.
Walls shall be capped to prevent moisture and
QUALITY AND CARE
precipitation from entering wall during
construction. All products originating from BASF facility are
manufactured under a management system
Limit the weather exposure of independently certified to conform to the
MasterSeal AWB 661I to a maximum of 120 requirements of the quality, environmental and
days in Middle East conditions. occupational health and safety standards of ISO
9001, ISO 14001 and OHSAS 18001.
STORAGE & SHELF LIFE * Properties listed are based on laboratory controlled tests.
Store in unopened containers in clean, dry place
® = Registered trademark of the BASF-Group in many countries.
protected liquid system components from
freezing. Store at no less than 4°C and below
BASF_CC-UAE/MSeal_AWB_661I_07_17/v1/
The technical information and application advice given in this BASF publication are based on the present state of
STATEMENT OF our best scientific and practical knowledge. As the information herein is of a general nature, no assumption can be
RESPONSIBILITY made as to a product's suitability for a particular use or application and no warranty as to its accuracy, reliability or
completeness either expressed or implied is given other than those required by law. The user is responsible for
checking the suitability of products for their intended use.

Field service where provided does not constitute supervisory responsibility. Suggestions made by BASF either
NOTE orally or in writing may be followed, modified or rejected by the owner, engineer or contractor since they, and not
BASF, are responsible for carrying out procedures appropriate to a specific application.

BASF Construction Chemicals UAE LLC


Disclaimer: the LRQA mark relates to
P.O. Box 37127, Dubai, UAE certified management system and not to
Tel: +971 4 8090800, Fax: +971 4 8851002 the product mentioned on this datasheet
www.master-builders-solutions.basf.ae
Method statement
MS - DS - MasterSeal AWB 661I - 07/2017

THIS METHOD STATEMENT COVERS PREPARATION AND APPLICATION OF


MasterSeal AWB 661I ON VARIOUS FRAMING AND SHEATHING/CARRIER BOARDS.

METHOD STATEMENT: MasterSeal AWB 661I

1. SURFACE PREPARATION:
1.1. The prepared surface must be dry, clean, sound and free of release agents, paint or other
residual coatings.

1.2. Verify the substrate is flat, free of fins or planar irregularities greater than 6.4 mm in 3 m.

1.3. Any unsatisfactory conditions should be reported to the main contractor and corrected
before application of the MasterSeal AWB 661I.

1.4. Substrate shall be of a type acceptable by BASF and installed as per substrate
manufacturer’s instructions and local building code requirements.

2. MIXING:
2.1. Mix MasterSeal AWB 661I with a clean rust-free paddle and drill until thoroughly blended.
Dilution of MasterSeal AWB 661I is not recommended.

3. APPLICATION:
3.1. A 20 mm (3/4) nap roller or stainless steel trowel is recommended to apply
MasterSeal AWB 661I.

3.2. Prewet new roller pads and spin out excess water, this should be done once only to ensure
The new roller pads fully saturate with the MasterSeal AWB 661I.

3.3. Apply the MasterSeal AWB 661I to all sheathing/carrier board joints.

3.4. Immediately install sheathing fabric and center over wet MasterSeal AWB 661I and
complete saturate sheathing fabric with MasterSeal AWB 661I.

3.5. Apply MasterSeal AWB 661I to the remaining sheathing/carrier board substrate at a
minimum wet film thickness of 330 microns.

3.6. Always ensure the roller is fully loaded to ensure an even application thickness of
MasterSeal AWB 661I.

Page 1 of 2
MS - DS - MasterSeal AWB 661I - 07/2017

3.7. Once the first coat of MasterSeal AWB 661I has cured, typically 2 to 4 hours visually inspect
to ensure that the surface is blister free and coating is free of voids and pinholes. Carry out
repairs if needed by applying additional MasterSeal AWB 661I such that the
MasterSeal AWB 661I is free of voids pinholes etc.

3.8. After the first coat of MasterSeal AWB 661I has been visually inspected and any needed
repairs have been carried out apply a second coat of MasterSeal AWB 661I at a consistent
minimum wet film thickness of 330 microns.

NOTE: Temperature, humidity, wind and substrate moisture can all affect curing time.

STATEMENT OF RESPONSIBILITY

The technical information and application advice given in this BASF publication are based on the present state of our best scientific and
practical knowledge. As the information herein is of a general nature, no assumption can be made as to a product's suitability for a
particular use or application and no warranty as to its accuracy, reliability or completeness either expressed or implied is given other than
those required by law. The user is responsible for checking the suitability of products for their intended use.

NOTE

Field service where provided does not constitute supervisory responsibility. Suggestions made by BASF either orally or in writing may be
followed, modified or rejected by the owner, engineer or contractor since they, and not BASF, are responsible for carrying out procedures
appropriate to a specific application.

Page 2 of 2
Job references
International Job References – MasterSeal AWB 661I
DATE PROJECT CONTRACTOR CONSULTANT COUNTRY

THE HEART OF EUROPE ST. PETERSBURG ISLAND VILLAS (102


SEAHORSES VILLAS + 7 FACILITY BLOCK (G+1) + 2 TYPICAL ACE INTERNATIONAL
2017/07 JK BAUEN BUILDING CONTRACTING LLC UAE
SUBSTATIONS + SWIMMING POOL) AT THE WORLD ISLANDS, CONSULTING ENGR
DUBAI, UAE
2B+G+49 FLOORS - WAFI HOTEL COMPLEX & MALL EXPANSION - ARKITEKNIK INTERNATIONAL
2017/05 AL FARAA GENERAL CONT. CO. UAE
PHASE 8 ON PLOT NO. 3153804, DUBAI, UAE CONSULTING ENGINEERS

2017/05 TP6 - SKY VENTURE ON YAS ISLAND - ABU DHABI, UAE ED ZUBLIN AG AECOM MIDDLE EAST LIMITED UAE

RESIDENTIAL BUILDING ON PLOT RB-W2-38, AL RAHA BEACH - ARCHITECTURAL & ENGINEERING


2017/02 DHABI CONTRACTING UAE
ABU DHABI, UAE CONSULTANTS
AL MEENA RESIDENTIAL / COMMERCIAL BUILDING (5B+3
DEWAN ARCHITECTS AND
2017/01 PODIUM+GF+MZ+36 FLOORS+ROOF) ON PLOT NOS. C56, C57 & ARABIAN CONSTRUCTION COMPANY UAE
ENGINEERS
C58 AT SECTOR E14, ABU DHABI, UAE
SERENIA RESIDENCES (B+G+9) ON PLOT NO. PJCRC35I - PALM
2016/10 KHANSAHEB CIVIL ENGINEERING LLC GAJ UAE
JUMEIRAH, DUBAI, UAE
AL MARYAH CENTRAL PROJECT AT SUPERPLOT CP-A, AL AECOM CANSULT MAUNSELL /
2016/08 BROOKFIELD MULTIPLEX CONSTRUCTIONS UAE
MARYAH ISLAND, ABU DHABI, UAE WSP MIDDLE EAST
Approvals
REVIEW COMMENT SHEET
Reference. No. [Rev] TP6-ZUB-04200-MS-000007 A0 08 May 2017

Project Name Sky Venture


Subject Material Submittal - Air/ Water-resistive barrier Membrane - BASF
Zone TBA Doc. Type: Material Submission

RESPONSE SUMMARY

Architect :
· NO objection contractor to clarify area’s where to apply and detail to be provided accordingly while the details shown in
the material submittal are general.

Sustainability:
No objection.

Attachments (if any): List down attachments in order and indicate the reference number where available.

Related Reference

REVIEWED AND
PREPARED BY: DOCUMENT STATUS
RECOMMENDED BY:
A – APPROVED ☐
B – APPROVED AS NOTED ☒

Haitham Samaan Mohammad Soudan


Sr. Architect Eng. Sustainability Engineer Zakari Awad C – REVISE AND RESUBMIT ☐
Sr. Projects Manager

Related reference D – OTHERS ☐


DRAFTER’S NOTE: APPROVED AS NOTED means document is Approved, resubmission not required. Comments to be incorporated into as-built / at handover and final documentation.

Distribution

¢Employer ¢Project Manager ¢Lead Consultant ¢Contractor ☐Others:


DOCUMENT REVISION HISTORY

REV NO. DESCRIPTION DATE OUR TRANSMITTAL

A0 Material Submittal - Air/ Water-resistive barrier Membrane - BASF 11 May 2017

FORM NO. MGT-FLP-01311-FO-T00115 This form is for use by Projects Development only and participants should
GENERAL
VERSION 00 register this document in Aconex platform for information, record and
NOTES
REVISION DATE 21 March 2016 future reference.
DISCIPLINE TRANSMITTAL
FORM NAME FORM OF REVIEW COMMENT SHEET DTD 20160321
C:\PROJECTS DOCUMENTS\TP6–SKY VENTURE\4 QA_QC\4.8 SUBMITTALS\4.8.3 MATERIAL SUBMISSION\ARCH\TP6-ZUB-04200-MS-000007[A0] AIR WATER-RESISTIVE BARRIER
FILE LOCATION
MEMBRANE_ACM.DOCX
> ?
@  A B C

>
B    B C

" # $ % & ' ( $ ) * + , - ( % . / 0 1 $ % , 2 $ & ( & 1 ( 3 $ 4 0 % % ( $ % 5 $ 6 7 % 0 # $

8
) 0 & & 9 : 0 ; < = % 7 0 % % ( $ %

         
                    

V
             !   

D E F G H I J K L M N O I P J Q H I J R P J O G H P L O K I S H P T O G I K U N V P L W Q N W W I H W

K G P L M S X I O G K O N J S Y P I K O L W H

Z E [ V V W P U N M K L Q \ H ] O O P V N K K I J R N K K H Y Q M ^ T I W H O H K O K

SHOP DRAWING REVIEW


The following document has been reviewed in terms of
technical content. This does not include dimensional
checking or checking of quantities. It also does not
include checking associated information that is not
called up on the drawing.

P
A. Accepted B. Accepted C. Accepted – D. Not
_ ` `
`
l `

_ a a b c d e f _ a a g b c d e f
t c b

Subject to Subject to Accepted –


p e q e r e f s

u n v c b m w c n x

h i j k
j i

Comment - No
l c m m e n

j o
Comment y c
Resubmit j i
n z r c a e

Resubmission Resubmit

Name:
{ |

Date: } ~  €   ‚ € ~ ƒ

Inhabit Asia ME

%0&200(176

4$4&5HYLHZD 0DWHULDOSURSRVHGE\FOLHQWE 6WRUHPDWHULDOVDVSHUPDQXIDFWXUHU


VUHFRPPHQGDWLRQ
Test reports
Certificate of Compliance
You have been awarded:

Intertek Warnock Hersey Mark for Building


Materials with Surface Burning Characteristics
ASTM E84 (2016)

Certificate number: WHI17 – 14632103

Organization:
BASF Construction Chemicals UAE LLC
This is a certificate of P.O. Box 37127
conformity to certify that the Dubai Investment Park
bearer has successfully Dubai, UAE
completed the requirements
of the above scheme which
include the testing of
products, the initial
assessment of their Factory
Product:
Production Control and are BASF – Enershield-I (ASTM E84)
subject to continuing annual
assessments of their Enershield-I is a one component fluid-applied vapor permeable air/water-resistive barrier.
continued Factory Production
Control compliance and RATINGS
testing of samples of products Test Standard Flame Spread Index Smoke Development Index
taken from production (as
applicable to the scheme) ASTM E84 25 or less 450 or less
and has been registered
within the scheme for the Based on Test Reports QJ080-1 and QJ080-2.
products detailed in the For full details of the certified product please refer to Spec ID 39881.
accompanying schedule.

Certification body: Intertek Testing Services NA, Inc.


Initial registration: February 27, 2017
Date of expiry: February 26, 2022
Issue status: 1

Dustin Behling
Certification Coordination Manager 27 Feb, 2017
Name Signature Date

Registered address:
Intertek Testing Services NA, Inc. 545 E. Algonquin Rd., Arlington Heights, IL 60005 USA
www.intertek.com
The certificate and schedule are held in force by regular annual surveillance visits by Intertek Testing & Certification Ltd and the reader or user should contact Intertek to validate its
status. This certificate remains the property of Intertek Testing & Certification Ltd and must be returned to them on demand. This Certificate is for the exclusive use of Intertek's Client
and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement.
Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this certificate. Only
the Client is authorized to permit copying or distribution of this certificate and then only in its entirety. Use of Intertek’s Certification mark is restricted to the conditions laid out in the
agreement. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory
Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of
production quality control and do not relieve the Client of their obligations in this respect.
United Arab Emirates ‫��مارات العربيةالمتحدة‬ ‫دول ة‬
Ministry of interior ‫لداخلية‬‫وزارة ا‬
Civil Defense G.H.Q t] ‫دفاع المدني‬‫القيادة العامةلل‬
‫لجنة اعتمادالمختبراتالعالمية‬
‫بيوت الخبرة ومعا هدالتدريب‬ ‫و‬

Date : August 2, 2018

CERTIFICATE OF COMPLIANCE WHI17 – 14632103 UAE

This certificate of compliance validates the following


TEST REPORT NUMBER 1. QJ080-1
‘Assessment Reports’ are not CERTIFICATE NUMBER WHI17 – 14632103
acceptable 2. QJ080-2
1. Jan 17, 2017
DATE OF ISSUE DATE OF ISSUE February 27, 2017
2. Jan 17, 2017

DATE OF EXPIRY Not Applicable DATE OF EXPIRY February 26, 2022

Manufacturer details

NAME OF FACTORY/
BASF Construction NAME OF THE BRAND MasterSeal AWB661I
MANUFACTURER
Chemicals UAE LLC

FACTORY ADDRESS / P.O. Box 37127


REGION Dubai Investment Park MODEL / NO
MasterSeal AWB661I
(STREET / TOWN / CITY / COUNTRY ) Dubai, UAE

http://www.master-
LOGO ON THE
WEBSITE builders-
PRODUCT N/A
solutions.basf.ae

TEL +971 4 8090800 EMAIL Ghassan.mansour@basf.com

‫بيوتالخبرة ومعا هدالتدريب‬


‫ لجنة اعتمادالمختبراتالعالمية و‬1
United Arab Emirates ‫��مارات العربيةالمتحدة‬ ‫دول ة‬
Ministry of interior ‫لداخلية‬‫وزارة ا‬
Civil Defense G.H.Q t] ‫دفاع المدني‬‫القيادة العامةلل‬
‫لجنة اعتمادالمختبراتالعالمية‬
‫بيوت الخبرة ومعا هدالتدريب‬ ‫و‬

Reference
Test
Product Details From Test Report Report
page NO
The MasterSeal AWB661I was roller applied in two coats for a
DESCRIPTION OF THE total thickness of 650 microns. The product was applied onto
PRODUCT fiber cement boards and allowed to dry for 7 days before being
(TECHNICAL DETAILS FROM TEST tested to ASTM E84-16. Page 5
REPORT, SUCH AS ACTUAL FIRE
RATINGS/DIMENSIONS/THICKNESS/
SENSITIVITY ETC) For full details of the certified product please refer to Intertek
Spec ID 39881.

TEST STANDARD ASTM E84; Standard Test Method for Surface Burning
(SUCH AS ASTM/BS EN/ DN ETC) Characteristics of Building Materials. 2016 Edition Page 4

The ASTM E84 test method is intended to compare the surface


flame spread and smoke developed measurements of different
samples. The test specimen surface is exposed to fire on one end
of the tunnel for the 10 minute test duration. The flame spread
and smoke development are measured and presented against
standard calibration materials.
TEST DESCRIPTION Page 6

The MasterSeal AWB661I was roller applied in two coats for a


total thickness of 650 microns. The product was applied onto six
SPECIFICATION OF TEST fiber cement boards measuring 610 ×1220 mm, giving a total
length of 7320 mm. Page 6
SPECIMEN

Test Standard Test Results


TEST RESULT
(SUCH AS PASSED CRITERIA___/ ASTM E84 FSI: 25 or less
Page 11
COMPLIED TO___/ SDI: 450 or less
DURATION___/OBSERVATION___/ETC)

PRODUCT APPLICATION MasterSeal AWB661I to be applied over suitable noncombustible


GUIDELINE exterior wall substrate, including but not limited to:
N/A
(END USE) concrete/masonry units, cement boards, noncombustible
(CLEARLY STATE THE END USE WITH sheathing.

‫بيوتالخبرة ومعا هدالتدريب‬


‫ لجنة اعتمادالمختبراتالعالمية و‬2
United Arab Emirates ‫��مارات العربيةالمتحدة‬ ‫دول ة‬
Ministry of interior ‫لداخلية‬‫وزارة ا‬
Civil Defense G.H.Q t] ‫دفاع المدني‬‫القيادة العامةلل‬
‫لجنة اعتمادالمختبراتالعالمية‬
‫بيوت الخبرة ومعا هدالتدريب‬ ‫و‬

SPECIFIC APPLICATION, SUCH AS


EXACT FIRE RATING/TO BE INSTALLED
IN___/TO BE INSTALLED AT____/TO BE Not to be used for below-grade applications or on surfaces
CONNECTED WITH____/TO BE
INSTALLED WITH___ ETC ALONG WITH
subject to water immersion.
ANY WARNINGS SUCH AS NOT TO BE
USED IN___/NOT TO BE INSTALLED
AT___/ NOT TO BE INSTALLED For full details of the certified product please refer to Intertek
WITH___ETC. Spec ID 39881 as well as the installation guidelines from the
manufacturer.

Laboratory and Certification body details


Thomas bell-wright
NAME OF CERTIFICATION Intertek Testing Services
NAME OF TEST FACILITY International
BODY NA. Inc.
consultants
P.O. Box 26385,
Corner of 46th and 47th
CERTIFICATION BODY 545 E. Algonquin Rd. TEST FACILITY ADDRESS / streets
ADDRESS / REGION Arlington Heights, IL REGION Jebel Ali Industrial
(STREET / TOWN / CITY / COUNTRY ) 60005 USA
Area 1
(STREET / TOWN / CITY / COUNTRY )

Dubai, UAE
WEBSITE www.intertek.com WEBSITE www.bell-wright.com

TEL (847) 439-5667 TEL +97143332692

EMAIL jp.kayl@intertek.com EMAIL fire@bell-wright.com

ACCREDITED BY International United Kingdom


(NAME OF ACCREDITATION BODY WHICH Accreditation Services
ACCREDITED BY Accreditation Services
(NAME OF ACCREDITATION BODY WHICH ISSUED
ISSUED ACCREDITATION TO THE
CERTIFICATION BODY, ALONG WITH (IAS) ACCREDITATION TO THE LABORATORY, ALONG (UKAS)
WEBSITE) (http://iasonline.org) WITH WEBSITE)
(https://www.ukas.com)

AS PER AS PER
(STANDARD TO WHICH THE ISO 17065 (STANDARD TO WHICH YOUR ORGANIZATION IS ISO 17025
CERTIFICATION BODY IS ACCREDITED TO) ACCREDITED TO)

From 18/10/2016
VALIDITY From 11/03/2016 VALIDITY expiry date not
(EXPIRY DATE OF CERTIFICATION BODY
expiry date not specified (EXPIRY DATE OF LABORATORY ACCREDITATION)
ACCREDITATION) specified

REFERENCE NUMBER: REFERENCE NUMBER:


(CERTIFICATION BODY ACCREDITATION
REFERENCE NUMBER TO VERIFY ON THE
PCA-101 (THE LABORATORY ACCREDITATION REFERENCE
NUMBER TO VERIFY ON THE ACCREDITOR’S
4439
ACCREDITOR’S WEBSITE) WEBSITE)

‫بيوتالخبرة ومعا هدالتدريب‬


‫ لجنة اعتمادالمختبراتالعالمية و‬3
TEST REPORT
REACTION TO FIRE TEST
TEST SPONSOR:
BASF Construction Chemicals UAE LLC
Dubai Investment Park, P.O. Box 37127
Jebel Ali Lehbab Road, Dubai, UAE
T: +971 4 809 0800, F: +971 4 885 1130
Website: www.basf.com

TESTED MATERIAL/ASSEMBLY:
Enershield I (Sample No. 4544)

TEST STANDARD:
ASTM E84-16: Standard Test Method for Surface Burning Characteristics of Building
Materials

Test Date: 23-Nov-16


Issue Date: 17-Jan-17
Test Reference No.: QJ080-1

PO BOX 26385, DUBAI UAE T +971 (0)4 333 2692 admin@bell-wright.com www.bell-wright.com

DUBAI ABU DHABI DOHA

Copyright© This document shall not be reproduced except in full without written approval of Thomas Bell-Wright International Consultants
Test Reference No.: QJ080-1

Accreditation
ISO/IEC 17025: General requirements for the competence of testing and calibration
laboratories with:

United Kingdom Accreditation Service (UKAS) - Testing Laboratory: 4439


www.ukas.com

GCC Accreditation Center (GAC) – Testing Laboratory: ATL-0017


www.GCC-accreditation.org

Memberships
Members of European Group of Organization for Fire Testing, Inspection and Certification
www.egolf.org.uk
Member of International Trade Council
www.thetradecouncil.com
Member of Association for Specialist Fire Protection
www.asfp.org.uk
Member of Centre for Window and Cladding Technology
www.cwct.co.uk

The work which is the subject of this report falls wholly or partly under the accreditations of ISO 17025
UKAS and ISO 17025 GAC.

Page 2 of 10
Test Reference No.: QJ080-1

Table of Contents

1. INTRODUCTION ....................................................................................................................................... 4
2. SPONSOR ................................................................................................................................................. 4
3. TESTING LABORATORY ............................................................................................................................ 4
4. DATE OF TEST .......................................................................................................................................... 4
5. SPECIMEN DESCRIPTION ......................................................................................................................... 5
6. METHOD OF TEST.................................................................................................................................... 6
6.1. Placing of test specimen ................................................................................................................. 6
6.2. Test Method .................................................................................................................................... 6
6.3. Conditioning .................................................................................................................................... 6
7. OBSERVATION ......................................................................................................................................... 6
8. SUMMARY OF RESULTS........................................................................................................................... 7
9. CLASSIFICATIONS .................................................................................................................................... 7
10. LIMITATIONS ....................................................................................................................................... 8
11. APPENDIX 1- GRAPHS.......................................................................................................................... 9
12. APPENDIX 2- PICTURES ..................................................................................................................... 10

Page 3 of 10
Test Reference No.: QJ080-1

1. INTRODUCTION
Determination of the flame spread index and the smoke developed index of Enershield I applied over
suitable substrate as per ASTM E84; Standard Test Method for Surface Burning Characteristics of Building
Materials.

2. SPONSOR
Name: BASF Construction Chemicals UAE LLC
Address: Dubai Investment Park, P.O. Box 37127
Jebel Ali Lehbab Road, Dubai, UAE
T: +971 4 809 0800
F: +971 4 885 1130
Website: www.basf.com

3. TESTING LABORATORY
Name: Thomas Bell-Wright International Consultants (TBWIC)
Address: Corner of 46th and 47th Streets,
Jebel Ali Industrial Area 1
Dubai, UAE
T: +971 (0)4 333 7992 | +971 (0)4 821 5777
Website: www.bell-wright.com

4. DATE OF TEST
Sample received: 14-Nov-16
Test date: 23-Nov-16

The test has been witnessed by:

Name Company Contact Number


Mr. Ghassan Mansour BASF Construction Chemicals +971 50 658 0375
Mr. Derek Spindler UAE LLC +971 56 696 7675
Mr. Ryan Ferry Intertek Middle East +971 54 306 4590

Page 4 of 10
Test Reference No.: QJ080-1

5. SPECIMEN DESCRIPTION
The description of the specimen given below has been prepared from information provided by the Sponsor.

Product Tested Enershield I (Sample No. 4544)


Fire side Exposed coated surface
Overall Coating Thickness 650 microns
Product Description Enershield I applied over suitable substrate
Product Name Enershield I
Product Reference Enershield I
Manufacturer BASF
Coating Product (fire side)

Colour Reference Pink


Number of Coats 2
Application rate per coat 1.4 sq. m per litre
Application method Product was mixed thoroughly until blended
and then applied with a roller on the surface
Product Details of the fiber cement boards
Curing process per coat 1st coat was allowed to dry for minimum
15minutes before application of the 2nd coat
7 days drying in ambient conditions after
application of 2nd coat
Thickness 650 microns in 2 coats
Specific gravity 1.51
Product Name UNICEM United Fiber Cement Board
Product Reference Fiber Cement board
Substrate

Manufacturer UNICEM
Colour Reference White
Thickness 6mm (±1mm)
Density 1.27 g/cm3
Dimensions per panel 1220 x 610mm (l x w) (measured)
No. of panel 6
Total dimension 7320 x 610mm (l x w) (measured)
6 sections of Enershield I applied over suitable substrate were butt
Specimen placement jointed end-to-end. The test specimen was placed directly to the tunnel
ledges with the exposed coated surface towards the flame source.

The test specimen was selected by Mr. Ryan Ferry of Intertek Middle East and the same was submitted by
the client.

Page 5 of 10
Test Reference No.: QJ080-1

6. METHOD OF TEST
6.1. Placing of test specimen
The test specimen consisted of 6 sections of Enershield I applied over suitable substrate. The dimension
per panel was 1220 x 610mm (l x w) and was butt jointed end-to-end. The total dimensions of the
specimen were 7320 x 610mm (l x w).
Several sections of cement board butt jointed end-to-end with overall dimensions of 7350 x 600 mm (l
x w), were placed at the back of the sample to protect the furnace lid assembly.
6.2.Test Method
The specimen was installed horizontally in the Steiner Tunnel and supported by the ledges. The exposed
coated surface of the specimen (fire side) was exposed to a flaming exposure during the 10 minute test
duration.
Flame spread and density of the smoke are measured and recorded while the results are computed
against the standard calibration materials (cement board and red oak flooring).
6.3.Conditioning
After delivery on 14-Nov-16, the specimen was stored in room temperature for 9 days prior to the test
ranging from 20.2 to 25.8°C and 45 to 55% relative humidity.

7. OBSERVATION
Test Data and Observation
Observations
Ignition Time (min:sec) 00:33
Time to maximum flame front advance (min:sec) 03:18
Maximum flame spread (ft) 5.0
Time to end of tunnel reached (min:sec) Not Reached
Maximum temp recorded at the exposed thermocouple located near
553/289
the end of the tunnel (ᵒF / ᵒC)
Dripping (min:sec) None
Flaming on the floor (min:sec) None
After flame on the top (min:sec) None
After flame on the floor (min:sec) None
Delamination (min:sec) 04:28
Sagging (min:sec) None
Shrinkage (min:sec) None
Fallout (min:sec) None

FS*Time Area (ft*min) 38.71


Smoke Area (%A*min) 106.67

Red Oak Smoke Area (%A*min) 85.2

Page 6 of 10
Test Reference No.: QJ080-1

8. SUMMARY OF RESULTS
The test specimen has been evaluated in accordance with ASTM E84; Standard Test Method for Surface
Burning Characteristics of Building Materials.

The test results are:

FLAME SPREAD INDEX (FSI) 20

SMOKE DEVELOPED INDEX (SDI) 125

Results are valid for the tested configuration only.

9. CLASSIFICATIONS
The following information is designed to help put these test results into context. Flame Spread Index and
Smoke Developed Index results from an ASTM E84 test are often used by regulatory agencies to approve
materials for various applications. For example, the International Building Code 2015, Section 803.1.1
requires that:

Interior wall and ceiling finish materials shall be classified in accordance with ASTM E84 or UL 723-10th Ed.
2008. Such interior finish materials shall be grouped in the following classes in accordance with their flame
spread and smoke-developed indexes.

Class A: Flame spread index 0 - 25; smoke-developed index 0 - 450.


Class B: Flame spread index 26 - 75; smoke-developed index 0 - 450.
Class C: Flame spread index 76 - 200; smoke-developed index 0 - 450.

Note that the above example is the IBC requirement for interior wall and ceiling finishes only; your
application may be different.

Page 7 of 10
Test Reference No.: QJ080-1

11. APPENDIX 1- GRAPHS

20
18
16
Flame Spread (feet)

14
12
10
8
6
4
2
0
0 1 2 3 4 5 6 7 8 9 10
Time (min)

Red Oak Calibration Test Specimen

Graph 1: Flame Spread Index (FSI)

100
90
80
% Light Absorption

70
60
50
40
30
20
10
0
0 1 2 3 4 5 6 7 8 9 10
Time (min)
Red Oak Calibration Test Specimen

Graph 2: Smoke Developed Index (SDI)

Page 9 of 10
Test Reference No.: QJ080-1

12. APPENDIX 2- PICTURES

Photo 1: Specimen before the test Photo 2: Specimen before the test
(Non-fire side) (Fire side)

Photo 3: Specimen after the test Photo 4: Specimen after the test
(located near the fire end) (located near the exhaust end)

- End of test report -

Page 10 of 10

You might also like