EVAPORATOR LOAD

PARAMETER
200 400 600 800 1000
T1 -5 -2.9 -2.4 5.2 13.4
T2 46.5 57.5 60.8 62.3 66.3
REFRIGERANT (R-134a)
T3 32.1 35 41 46.1 50.1
T4 -32.9 -11.9 -2.1 5.8 11.8 C
MASS FLO 2 3 4.5 6 7.5
GAUGE 0.75 0.875 1.05 1.2 1.35
Pc
ABSOLUTE 0.85 0.975 1.15 1.3 1.45 5
GAUGE 0.025 0.1 0.175 0.26 0.35
Pe 4.5
ABSOLUTE 0.125 0.2 0.275 0.36 0.45
SPRING BALANCE 9 11 12.5 14 15.5 4
COMPRESSOR SPEED 782.4 775.4 765.6 761.5 754.8
MOTOR SPEED 1549.152 1535.292 1515.888 1507.77 1494.504 3.5
h1 297 300 310 306 308
3
h2 330 337 344 350 345
h3 147 154 166 168 172 2.5
h4 147 154 166 168 172
2

1.5
THERMODYNAMIC PROPERTIES
1
EVAPORATOR LOAD 0.3 0.438 0.648 0.828 1.02
COMPRESSOR POWER 0.066 0.111 0.153 0.264 0.2775 0.5
C.O.P 4.545455 3.945946 4.235294 3.136364 3.675676
0
-5
DIRECT METHOD C.O

EVAPORATOR LOAD 0.2 0.4 0.6 0.8 1


COMPRESSOR POWER0.107073 0.159171 0.196449 0.234476 0.271149
MOTOR POWER 0.24091 0.291811 0.327413 0.364739 0.400265
FRICTION POWER 0.133837 0.13264 0.130964 0.130262 0.129116
C.O.P 1.867889 2.513014 3.054224 3.411858 3.688015
C.O.P against Temperature, T1 C.O.P Thermod
C.O.P Direct M

4.5

3.5

2.5

1.5

0.5

0
-5 -2.9 -2.4 5.2 13.4
T1
C.O.P Thermodyna mi cs C.O.P Di rect Method
T1
-5 -2.9 -2.4 5.2 13.4
4.545 3.946 4.235 3.136 3.676
1.868 2.513 3.054 3.412 3.688