MINISTRY OF HOUSING
Project Name:
250 A B C D E
B02 B02 B02 B02 B02
2900 2450 2250 2250 3400 4350
3500
STUDIES & DESIGN SERVICES FOR
2700
3 8500 HOUSING PROJECTS IN CENTRAL
SE-102 AREAS SECTOR FOR
2850 1400 1400 2850 MINISTRY OF HOUSING
250 400
350 400
ZUHAIRFAYEZ P ARTNERSHIP
CONSULTANTS
250
250
ARCHITECTURE, ENGINEERING
AND INFORMATION SYSTEMS
P.O.Box 9486 , Riyadh 11413 Saudi Arabia
Tel. : 011 - 404 8484 / Fax : 011 - 404 8400
E.Mail Address : ZFPR@ZFP.com
300 2625 300 2150 300 1950 300 1950 300 3100 300 4050 300 Notes:
1750
PROTECTION BOARD PROTECTION BOARD
-SEE GENERAL NOTES & GENERAL DETAILS ON DWGS
2650
NO.(G3-14-GS-001, G3-14-GS-002 & G3-14-GS-003)
3500
-ALL DIMENSIONS ARE IN MILLIMETERS UNLESS
3400
W.P.M W.P.M
OTHERWISE MENTIONED.
850
REFER TO MECHANICAL DRAWINGS.
310
2
-ROOF DESIGN IS BASED ON LIVE LOAD OF 2 KN/m
350
2
ON THE AREA ABOVE TANK AND 3 KN / m ON THE
100
AREA ABOVE PUMP ROOM.
100 500 300 3950 300 3950 300 500 100 -THE TANK TEST SHALL BE CARRIED OUT AFTER THE
PLAIN CONCRETE FOR SLOPE FULL CONSTRUCTION OF THE TANK ELEMENTS ( FLOOR
1A SECTION R.C. FLOOR SLAB
,WALLS AND ROOF SLAB) AND THERE IS NO BACKFILLING
SE-102 1:50 CONCRETE DIM. AROUND THE TANK.
50 mm. SCREED
- AS PER SOIL REPORT FOUNDATION DESIGN IS
WATERPROOF MEMBRANE
BASED ON BEARING CAPACITY "300KN/m2"
100 mm. P.C.
2A SECTION
SE-102 1:50 CONCRETE DIM.
01 02 03 04 05 06 07
IB02 IB02 IB02 IB02 IB02 IB02 CHLORINE SHED IB02
A B C D E
B02 B02 B02 B02 B02
2900 2450 2250 2250 3400 4350
8500
250
Ø12@200 B Ø14@150 B
Ø14@150 B
Ø12@150 Ø16@150 E.F. Ø16@150 E.F. Ø16@150 E.F.
VERT. Ø16@150 E.F. Ø16@150 E.F.
VERT. VERT. VERT. Ø16@150 E.F. Ø12@150 E.F
Ø12@150 VERT. Ø16@150 E.F. VERT.
HORZ. Ø16@150 E.F.
HORZ. E.F. VERT. VERT.
Ø12@150 T VERT.
Ø12@150 E.F. Ø12@150 E.F. Ø12@150 E.F. Ø12@150 E.F. Ø16@150 E.F.
Ø12@150 E.F.
HORZ. HORZ. HORZ. HORZ. VERT.
3500
Ø12@150 E.F.
HORZ.
HORZ. Ø12@150 E.F.
HORZ. Ø12@150 E.F.
HORZ.
Ø12@150 B
350
4Ø16 4Ø16
100
Ø16@150 B 4Ø16 4Ø16 Ø16@150 B Ø16@150 B 4Ø16
1B SECTION 2B SECTION
SE-102 SE-102 1:50 REINFORCEMENT DETAILS
1:50 REINFORCEMENT DETAILS
06 07
06 07 IB02 IB02
IB02 IB02 4350
4350
350mm THK. FLAT SLAB W/RFT.
Ø14@150 E.W BOTT.,
Ø12@150 E.W TOP. CHLORINE SYSTEM
STEEL POST PRECAST CONC.
100mm SLAB W/A 193 W.W.F STEEL POST 100X100X3
ON GALV. METAL DECK H REVISED DESIGN DEVELOPMENT STAGE SEP. 2018 HAG
100X100X3
W/0.7mm thk E G REVISED DESIGN DEVELOPMENT STAGE JULY 2018 HAG
250 2090 2010
E B02 250 2090 F REVISED DETAILED DESIGN DRAWINGS JUNE 2017 MHK
B02
4Ø16 T&B
E ISSUED FOR TENDER APR.2015 HAG
150 513
STEEL BEAM
150
RHS 100X150X3
STEEL BEAM
STEEL BEAM
1400
1400
1790
2850
B1 Key Plan :
637 150
STEEL BEAM
RHS 100X150X3 D
D B02 4 BASE PLATES
B02 150X150X20 (TYP.)
W/ ANCHORS 4M12 (TYP.)
1:50 G3-14-IB02-SE-102 H