Technical Sheet – K0037

Multifunction Analyzer
Revision 1.0 – 02.18.2010
Mult-K Grafic
[1] Introduction
The Mult-K Grafic is a digital micro-processed instrument,
to be installed on a panel’s door, allowing the measurement
of up to 101 electrical parameters at an alternate current
system (AC). The parameter reading can be performed
locally or remotely.
As an option, it can be equipped with a mass memory,
which allows the history storage of up to ten electrical
greatnesses with a minimum interval of 1 minute.
Complementing the successful Mult-K line, the Mult-K
Grafic incorporates new benefits like the programmable
LCD display, storage of minimums and maximums on the
proper instrument and new measurement parameters.
There is also the option of supplying the Mult-K Grafic with
special external current transformers (split core). Illustrative photo

[2] Operation and applications [4] Accuracy


By means of the voltage and current signals from the • Voltage, current, power: 0,2%*
system to be measured (mono-phase, two-phase or three- • Frequency: 0.1Hz
phase), the Mult-K Grafic calculates the electrical • Power factor: 0,5%*
parameters, using a high resolution internal A/D converter, • Energy: 0,5%
with 64 samples per cycle.
• THD: <3%
The multifunction analyzer can be applied either on low (at 25°C, observing the recommended voltage and cur rent
voltage or on high voltage systems, as it is possible to ranges)
program the relation of the PT (potential transformer) or the
CT (current transformer) involved in the measurement. * Accuracy refers to the scale background

• Substation automation; [5] Electrical Characteristics


• Industrial and premise automation;
• Circuits and electrical equipment analysis; AUXILIARY SUPPLY
• Survey of the loading curve and history of an electric • Nominal: 12*, 24 or 48Vdc / 120-220Vac
circuit;  Utilization range: 80 to 120% of nominal value
• Costs allotment;
• TOP Source: 85-265Vac and 100-375Vdc
• Analogical instruments replacement;
• Internal consumption: < 10 VA
• Any application involving electrical parameter
measurements. * Utilization range of 90 to 120% of nominal value.
[3] Measured greatnesses VOLTAGE INPUT (MEASUREMENT)
Measurement of up to 101 electrical parameters, as • Operation range: 20 to 500Vac (F-F)
follows:
• Overcharge: 1.5 x Vmax (1s)
• Voltage (phase-phase, phase-neutral and three- • Operation frequency: 44 to 72Hz
phase)* • Internal consumption: < 0.5 VA
• Frequency*
• Current (per phase, neutral and three-phase)* CURRENT INPUT (MEASUREMENT)
• Active power (per phase and three-phase)* • Nominal (In): 1Aac or 5Aac
• Reactive power (per phase and three-phase)* • Minimal indication: 20mA
• Apparent power (per phase and three-phase)* • Full Scale:
• Power Factor (per phase and three-phase)*  1.5 x In (standard)
• THD (per voltage and current phase, up to the 31st  2 x In (optional)*
order)* • Short duration overload:
• Active demand (average and maximum)  20 x In (1s)
• Apparent demand (average and maximum) • Internal consumption: < 0.5 VA
• Active power (positive and negative)
• Reactive power (positive and negative) *Only for nominal current of 5Aac, full scale of 10Aac.
*Includes maximum and minimum measurements

KRON Instrumentos Elétricos Ltda.


Phone: (11) 5525-2000
Website: http://www.kron.com.br - Email: energia@kron.com.br 1/10
Technical Sheet – K0037
Multifunction Analyzer
Revision 1.0 – 02.18.2010
Mult-K Grafic
[6] Mechanical Characteristics [8] Serial Interface
DISPLAY Standard

• Type: Blue LCD with backlight • Type: RS-485 with 2 wires


• Size: 128 x 64 pixels • Speed: 9600, 19200, 38400 or 57600bps
(configurable)
See details in item 12 (configurable Display)
• Data format: 8N1, 8N2, 8E1, 801 (configurable)
• Address: 1 to 247 (configurable)
ENCLOSURE
• Protocol: MODBUS-RTU
• Material: thermoplastic (ABS V0) • Information encoding:
• Protection grade: IP-40 for front panel (option for
MODBUS-RTU beginning with version 1.1:
IP-54) and IP-20 for enclosure (option for IP-40)
FlexData mapping, with configurable floating point
ASSEMBLY
IEEE 754 (32 bits), reading formats at 16 bits (totally
signaled and not signaled) and floating point of 24 bits
• Type: panel’s door (overlap)
for mass memory.
• Assembling position: any
• Fastening: side latches • Cable: For RS-485, a shielded cable must always
be used, with at least two ways (2x24 AWG),
ELECTRICAL CONNECTIONS minimum section of 0.25mm² and characteristic
impedance of 120ohms.
• Type: quick coupling terminal
• Protection grade: IP-00 Optional – Ethernet Output
• Maximum cable to be used: 2.5mm²
• Type: Ethernet Port
[7] Relevant environmental conditions • Speed: 10/100 Mbits/s
• Protocol: MODBUS-TCP/IP or MODBUS-TCP/IP
• Operation temperature: 0 to 60ºC (encapsuled)
• Storage and transport temperature: -25 to 60º C
• Relative air humidity: 90% maximum (without [9] Pulses Output (optional)
condensation)
• Temperature coefficient: 50ppm / ºC • Type: open collector
• Parameters: positive active power (output 1) and
positive reactive power (output 2)
• Pulse width: 200ms
• Maximum current: 1mA
• Maximum frequency: 1Hz

[10] Applicable software programs

• Software for reading and parameterization:


Network MB5 5.19 or higher (freely supplied by
KRON)
• Compatible with supervisory applications, CLPs
and concentrators that support MODBUS-RTU
protocol

KRON Instrumentos Elétricos Ltda.


Phone: (11) 5525-2000
Website: http://www.kron.com.br - Email: energia@kron.com.br 2/10
Technical Sheet – K0037
Multifunction Analyzer
Revision 1.0 – 02.18.2010
Mult-K Grafic
[11] Connection Diagrams

Terminal description:

Terminal Description Terminal Description


1 Voltage Vc 11
2 Voltage Vb 12 Auxiliary supply
3 Voltage Va 13
4 Neutral 14 Serial: DATA-
5 Current Ic 15 Serial DATA+
6 Current •Ic 16 Serial: Ground
Reactive Pulse:
7 Current Ib 17
C
Reactive Pulse:
8 Current •Ib 18
E
9 Current Ia 19 Active Pulse: C
10 Current •Ia 20 Active Pulse: E

Description of terminals related to the auxiliary supply:

Power source Power source DC Power source TOP


(120 or 220 Vac) (12/24/48 Vdc) (85 to 265 Vac or 100 to 375 Vdc)
220 Vac 11 13
11 13
11 12 13 + -
85 to 265 Vac
12 / 24 / 48 100 to 375 Vdc
Vdc There is no polarity for direct current signal.
120 Vac Respect polarities

Recommendations

• Recommended cable: minimum section of 1.5mm² for auxiliary voltage and supply.

• For current signal, the sizing depends on the distance and power of the CTs involved.

• The auxiliary supply (terminals 11, 12 and 13) must always be made according to the label affixed on the
instrument.

• In the case of utilization of the TOP SOURCE, the supply must be connected to terminals 11 and 13
respecting the characteristic limits, without the need of observing the polarization if the input signal is either
continuous or alternate.

KRON Instrumentos Elétricos Ltda.


Phone: (11) 5525-2000
Website: http://www.kron.com.br - Email: energia@kron.com.br 3/10
Technical Sheet – K0037
Multifunction Analyzer
Revision 1.0 – 02.18.2010
Mult-K Grafic
[11] Connection Diagrams (continued)
TL-00: Three-phase Star (3F + N) TL-01: Two-phase (2F + N)

TL-03: Balanced Three-phase (3F + N, with measurement of


TL-02: Monophase (1F + N)
just 1 element)

TL-49: Three-phase Delta (3F, with measurement of


TL-48: Three-phase Delta (3F)
just 2 elements)

• In the case of using external transformers, those shall be of measurement.


• The use of a PT (potential transformer) is unnecessary for voltages below 500 Vac (F-F).
• Never leave the secondary of the CTs in the open mode, do not use fuses or circuit breakers in series with the current circuit and do not
use the CTs with operation current above the permitted level. It is recommended the installation of an admeasurement block.
• The grounding indicated by dots in the diagrams are recommended for safety reasons and do not directly interfere in the instrument’s
measurement or accuracy.

KRON Instrumentos Elétricos Ltda.


Phone: (11) 5525-2000
Website: http://www.kron.com.br - Email: energia@kron.com.br 4/10
Technical Sheet – K0037
Multifunction Analyzer
Revision 1.0 – 02.18.2010
Mult-K Grafic
[12] Configurable Display
Associated to its high precision and reliability, Mult-K Grafic
VOLTAG L- L 60.00 Hz
has a graphic display, which makes it easier and more
intuitive the visualization of the measured electrical
parameters.
L1
220.3 V
Besides its easiness of operation, Mult-K Grafic allows
L2
221,1 V
the user to configure through its own MMI or through
software RedeMB5 the customized screens, including
L3
220,8 V
combinations of measured greatnesses. The user can
configure up to three customized screens, using three
distinct predefined models.*

TYPE 1 CUSTOMIZED SCREEN: Screen with three measurement parameters

Characteristics

• Up to three greatnesses May be defined.


• The frequency (4th parameter) is always shown.

Usage example: measurement of voltage + current +


power

TYPE 2 CUSTOMIZED SCREEN: Screen with one measurement parameter and bar graph

Characteristics

• Greatness must be defined.


• The frequency (2nd parameter) is always shown.
• Besides the greatness value, a bar graph is shown and
has its scale automatically updated.

Usage example: measurement only of phase 1 voltage,


in replacement for an analogue voltmeter.

TYPE 3 CUSTOMIZED SCREEN: Screen with six measurement parameters

Characteristics

• Six greatnesses must be defined.


• The frequency (7th parameter) is always shown.

Usage example: test bench or other applications where


it is necessary to indicate various parameters at the
same time.

Additionally, the user can also configure the Display contrast thru the MMI (digital adjustment), as
well as invert the operational colors (reverse mode).

Ultimately, still is possible to define the instrument’s MMI language (Portuguese or English),
adapting the instrument usage to any type of market or final client.

*Energies and Demands cannot be configured on customized screens.

KRON Instrumentos Elétricos Ltda.


Phone: (11) 5525-2000
Website: http://www.kron.com.br - Email: energia@kron.com.br 5/10
Technical Sheet – K0037
Multifunction Analyzer
Revision 1.0 – 02.18.2010
Mult-K Grafic
[13] Mass Memory (optional)
Application: It is a non-volatile memory (the data are not lost in case of lack of auxiliary supply), which
allows to record the historical behavior of up to 10 (ten) electrical greatnesses.

The mass memory of the Mult-K Grafic can be configured with a minimum interval of 1 minute
and maximum interval of 540 minutes (9 hours), and the time for filling the memory will depend on the
quantity of greatnesses chosen and on this storage interval.

The information is stored in a floating point format, 24 bits, containing its date and time, originated
from an internal clock existing on the multimeter.

• Type: non-volatile memory (retentive)


• Capacity: 512 kBytes
• Storage mode: circular (when memory capacity is exhausted, older data is erased to write
new data, by sectors) or linear (when memory capacity is exhausted, data stops being stored).
• Quantity of greatnesses possible of being stored: 1 to 10 greatnesses
• Minimum interval between writings: 1 minute
• Maximum interval between writings: 540 minutes (9 hours)

The stored data can be collected through a serial interface, utilizing CLPs, data concentrators,
supervisory applications or software NetworkMB5 (freely supplied). This software permits to export the
information to a text file, with no formatting (text – “txt”), facilitating the composition of graphics using
Excel, for instance.

The table below contains the maximum information quantity that can be stored, varying according
to the number of selected greatnesses:

Examples of time to fill the


Quantity of
Total of registers memory for a 15 minutes
greatnesses
interval (in days)
1 58236 606
2 43677 454
3 34940 364
4 29118 303
5 24958 260
6 21837 227
7 19405 202
8 17470 182
9 15877 165
10 14559 152

Through the MMI (man-machine interface) it is possible to configure and verify the mass memory
parameters such as:

Mode: Circular or linear


SI (storage interval): 1 to 540 minutes
Configured greatnesses: 1 to 10
Space used from memory in percentage

KRON Instrumentos Elétricos Ltda.


Phone: (11) 5525-2000
Website: http://www.kron.com.br - Email: energia@kron.com.br 6/10
Technical Sheet – K0037
Multifunction Analyzer
Revision 1.0 – 02.18.2010
Mult-K Grafic
[14] Special External Transformers
With Mult-K Grafic, it is possible to use special external current transformers of the split core type.
This allows the installation to be performed without the need of disconnecting the main power.

Split Core

Besides the easiness of installation, they have reduced dimensions, facilitating, for instance, its utilization on
locations with space limitation. There are two models for fixed use:

Model 1:

Transformers that must be used in a fixed way, that is, the clamp should not be opened and closed many times
as this might change the measurements.

Maximum Current

80Aac

120Aac

160Aac

Model 2:

The clamp can be opened and closed up to 50 times without resulting in measurement changes.

Maximum Current

120Aac

200Aac

300Aac

Considerations and Recommendations

The special external transformers must always be connected according to the phase indicated in
the label For instance, a transformer with inscription “PHASE A” must only be connected to
inputs “.Ia” and “Ia” from the meter. The procedure is analogue for phases Band C.

Each instrument is supplied with its own set of these transformers and there is no way of using
another one, even if it has the same nominal current value.

NEVER DISCONNECT THE SPECIAL EXTERNAL TRANSFORMERS FROM THE


METER WHILE THEY ARE CONNECTED TO THE LOAD.

THE REMOVAL OF THE CONNECTIONS IN THE ABOVE SITUATION WILL CAUSE


DAMAGE TO THE METER AND HIGH SAFETY RISKS.

NOTE: The maximum cable length that connects the special external transformers to the meter
terminals is of 1 meter.

KRON Instrumentos Elétricos Ltda.


Phone: (11) 5525-2000
Website: http://www.kron.com.br - Email: energia@kron.com.br 7/10
Technical Sheet – K0037
Multifunction Analyzer
Revision 1.0 – 02.18.2010
Mult-K Grafic
[15] Dimensions

Dimensions in millimeters.
Tolerance: ± 1mm

MULT-K GRAFIC

FRONT VIEW SIDE VIEW PANEL SECTION

Special External Transformers: Split Core

Model 1

Current A B C D E F (Max.) G (± 3)
80 A 10 25 26 40 14 1000 10
120 A 16 29 31 44,5 18,5 1000 10
160 A 24 45 34 64 22 1000 10
Model 2
120 A Current 200 A and 300 A Currents

KRON Instrumentos Elétricos Ltda.


Phone: (11) 5525-2000
Website: http://www.kron.com.br - Email: energia@kron.com.br 8/10
Technical Sheet – K0037
Multifunction Analyzer
Revision 1.0 – 02.18.2010
Mult-K Grafic
[16] Mult-K Grafic with Ethernet output

As an option, the Mult-K Grafic can be produced with an Ethernet output.

It has an internal server that makes it possible to read the electrical greatnesses and the instruments’ configuration
with an Internet browser (Internet Explorer, Firefox, Netscape, etc.), and up to 8 users can access simultaneously the
pages.

It can operate with static or dynamic IP addresses, and the configuration is executed by means of a web page.

[17] Normalizations
The products of the Mult-K line meet the following standards:

• IEC 61326-1
• IEC 61000-4-2
• IEC 61000-4-3
• IEC 61000-4-4
• IEC 61000-4-5
• IEC 61000-4-6
• IEC 61000-4-8
• IEC 61000-4-11
• CISPR 11

KRON Instrumentos Elétricos Ltda.


Phone: (11) 5525-2000
Website: http://www.kron.com.br - Email: energia@kron.com.br 9/10
Technical Sheet – K0037
Multifunction Analyzer
Revision 1.0 – 02.18.2010
Mult-K Grafic

[18] Specification by code [19] Special versions


The product codification allows the correct project • Full Scale 10 Aac
specification, ensuring that the purchased material is
exactly the necessary for the application. Made available upon order specification, version with
The identification is made by an alphanumeric sequence of support to measurement of up to 10 A.
11 characters:
NOTES:
Z Fixed
Mass memory:
a) Termination: Eyelet terminal only.
__ 5: without mass memory
6: with mass memory b) Auxiliary Supply: Top source only.
8 Fixed c) Output: RS-485 only
Protection grade:
1: Standard (It cannot be produced with Pulse or Ethernet
2: IP-54 for front panel and IP20 for enclosure outputs)
1 3: IP-54 for front panel, IP-20 for enclosure + sealing rubber
4: IP-40 for front panel and IP-40 for enclosure
5: IP-54 for front panel and IP-40 for enclosure
6: IP-54 for front panel, IP-40 for enclosure + sealing rubber

5 Voltage input:
5: 20 to 500Vac (F-F)
Current input:
1: 1Aac
3: Split Core 1
__
4: Split Core 2
5: 5Aac (Imax = 7.5.Aac)
6: 5 Aac (Imax = 10 Aac – only with eyelet terminal)**
Frequency:
__ 1: 60Hz
2: 50Hz
Output:
1: RS-485
2: Pulses output
__
3: RS-485 + Pulses output
4: Ethernet Output
0: No output
Auxiliary supply:
1: 120/220Vac
2: TOP Source: 85-265Vac / 100-375Vdc
__
4: 48Vdc
5: 24Vdc
6: 12Vdc
Termination: The information contained in this technical sheet is subject to changes without
previous notice.
__ 0: Standard1
1: Eyelet terminal For correct utilization of the product, the User Manual must be consulted
before its installation or operation.
Protocol / special version:
Some items presented herein may be optional, being necessary the correct
0 0: MODBUS-RTU product specification by means of a code.
1: MODBUS-TCP/IP ***
2: MODBUS-TCP/IP (encapsuled) ***
Device disposal
Notes on encoding: Products showing this symbol must be disposed
of separately from regular domestic residues,
1) The bold signaled items indicate the standard option according to the local environmental legislation.
having higher stock availability;
In case you do not obtain safe information,
2) For 125Vdc auxiliary supply, consider item 2 (TOP contact our technical assistance on the phone
source). (11) 5525-2027 or through the www.kron.com.br
website.
*** Solely for model with Ethernet output.

KRON Instrumentos Elétricos Ltda.


Phone: (11) 5525-2000
Website: http://www.kron.com.br - Email: energia@kron.com.br 10/10

You might also like