Professional Documents
Culture Documents
IP Sterility Testing
IP Sterility Testing
Test Procedures
Either of the following methods, Method A- Membrane Filtration or Method B- Direct
Inoculation, may be followed.
Method A is to be preferred where the substance under examination is
(a) an oil,
(b) an ointment that can be put into solution,
(c) a non-bacteriostatic solid not readily soluble in the culture medium, and
(d) a soluble powder or a liquid that possesses bacteriostatic and/or fungistatic properties.
For liquid products where the volume in a container is 100 ml or more, Method A should be
used.
Select the number of samples to be tested from Table 1 and use them for the culture medium
for bacteria and the culture medium for fungi.
General.
The exterior surface of ampoules and closures of vials and bottles should be cleaned with a
suitable antimicrobial agent and access to the contents should be gained in a suitable aseptic
manner. If the contents are packed in a container under vacuum, sterile air should be admitted
by means of a suitable sterile device, such as a needle attached to a syringe barrel filled with
non-absorbent cotton.
Method A- Membrane Filtration
The method calls for the routine use of positive and negative controls. A suitable positive
control is the occasional use of a known contaminated solution containing a few
microorganisms of different types (approximately 10 CPU in the total volumes employed).
Apparatus
A suitable unit consists of a closed reservoir and a receptacle between which a properly
supported membrane of appropriate porosity is placed. A membrane generally suitable for
sterility testing has a nominal pore size not greater than 0.45 µm and diameter of
approximately 50mm, the effectiveness of which in retaining microorganisms has been
established. Cellulose nitrate filters are used for aqueous, oily and weakly alcoholic solutions
and cellulose acetate filters, for strongly alcoholic solutions. Preferably assemble and sterilise
the entire unit with the membrane in place prior to use. Where the sample to be tested is oil,
sterilise the membrane separately and, after thorough drying, assemble the unit using aseptic
precautions.
Diluting Fluids
Fluid A. Dissolve 1g of peptic digest of animal tissue (such as bacteriological peptone) or its
equivalent in water to make 1 litre, filter or centrifuge to clarify, adjust to pH 7.1 ± 0.2,
dispense into flasks in 100-mI quantities and sterilise at 121oC for 20 minutes.
NOTE- Where fluid A is to be used in performing the test for sterility on a specimen of the
penicillin or cephalosporin class of antibiotics, aseptically add a quantity of sterile
penicillinase to the fluid A to be used to rinse the membrane(s) sufficient to inactivate any
residual antibiotic activity on the membrane(s) after the solution of the specimen has been
filtered.
Fluid B. If the test sample contains lecithin or oil, use fluid A to each litre of which has been
added 1 mI of polysorbate 80,adjust to pH 7.1 ± 0.2, dispense into flasks and sterilise at
121oC for 20 minutes.
NOTE - A sterile fluid shall not have antibacterial or antifungal properties if it is to be
considered dissolving, diluting or rinsing a preparation being examined for sterility.
Quantities of Sample to be used
For parenteral preparations.
Whenever possible use the whole contents of the container, but in any case not less than the
quantities prescribed in Table 3, diluting where necessary to about 100 ml with a suitable
diluent such as fluid A.
For ophthalmic and other non-parenteral preparations. Take an amount within the range
prescribed in column (A) of Table 4, if necessary, using the contents of more than one
container, and mix thoroughly. For each medium use the amount specified in column (B) of
Table 4, taken from the mixed sample.
Method of Test
For aqueous solutions. Prepare each membrane by aseptically transferring a small quantity
(sufficient to moisten the membrane) of fluid A on to the membrane and filter it. For each
medium to be sterilised, transfer aseptically into two separate membrane filter funnels or to
separate sterile pooling vessels prior to transfer not less than the quantity of the preparation
under examination that is prescribed in Table 3 or Table 4.
Alternatively, transfer aseptically the combined quantities of the preparation under
examination prescribed in the two media onto one membrane. Draw the liquid rapidly
through the filter with the aid of vacuum. If the solution under examination has antimicrobial
properties, wash the membrane(s) by filtering through it (them) not less than three successive
quantities, each of 100 mI, of sterile fluid A. Do not exceed a washing cycle of 5 times or
200mI, even if it has been demonstrated during validation that such a cycle does not fully
eliminate the antimicrobial activity. The quantities of fluid used should be sufficient to allow
growth of a small inoculum of organisms (approximately 50 CFU) sensitive to the
antimicrobial substance in the presence of the residual inhibitory material on the membrane.
After filtration, aseptically remove the membrane(s) from the holder, transfer the whole
membrane or cut it aseptically into 2 equal parts. Transfer one half to each of two suitable
media. Use the same volume of each medium as in the procedure for Validation of Tests.
Alternatively, transfer the medium onto the membrane in the apparatus. Incubate the media
for not less than 14 days. Observe the containers of media periodically during the 14 days of
incubation. If the test specimen is positive before 14 days of incubation, further incubation is
not necessary. For products terminally sterilised by a validated moist heat process, incubate
the test specimen for not less than 7 days.
For liquids immiscible with aqueous vehicles, and suspensions. Carry out the test
described under For aqueous solutions but add a sufficient quantity of fluid A to the pooled
sample to achieve rapid filtration. Sterile enzyme preparations such as penicillinase or
cellulase may be added to fluid A to aid in dissolving insoluble substances. If the substance
being examined contains lecithin, use fluid B for diluting.
For oils and oily solutions.
Filter oils or oily solutions of sufficiently low, viscosity without dilution through a dry
membrane. Dilute viscous oils as necessary with a suitable sterile diluent such as isopropyl
myristate that has been shown not to have antimicrobial properties under the conditions of the
test. Allow the oil to penetrate the membrane and filter by applying pressure or by suction,
gradually. Wash the membrane by filtering through it at least three successive quantities,
each of approximately 100 ml, of sterile fluid B or any other suitable sterile diluent.
Complete the test described under
For aqueous solutions, beginning at the words "After filtration, ".
For ointments and creams. Dilute ointments in a fatty base and emulsions of the water-in-
oil type to give a fluid concentration: of 1 per cent w/v, by heating, if necessary, to not more
than 40° with a suitable sterile diluent such as isopropyl myristate previously rendered sterile
by filtration through a 0.22µm membrane filter that has been shown not to have antimicrobial
properties under the conditions of the test. Filter as rapidly as possible and complete the test
as described under For oils and oily solutions, beginning at the words ''Wash the membrane
by ". In exceptional cases, it may be necessary to heat the substance to not more than 44° and
to use warm solutions for washing the membrane.
NOTE - For ointments and oils that are insoluble in isopropyl myristate, use Method B.
For soluble solids. For each medium, dissolve not less than the quantity of the substance
under examination, as prescribed in Tables 3 and 4, in a suitable sterile solvent such as fluid
A and Carry out the test described under For aqueous solutions using a membrane appropriate
to the chosen solvents.
For solids for injection other than antibiotics. Constitute the test articles as directed on the
label, and carry out the test as described under For aqueous solutions or For oils and oily
solutions, as applicable.
NOTE – If necessary, excess diluent may be added to aid in the constitution and filtration of
the constituted article.
For antibiotic solids, bulks, and blends.
Aseptically remove a sufficient quantity of solids from the appropriate amount of containers
prescribed in Table 3, mix to obtain a composite sample, equivalent to about 6 g of solids,
and transfer to a sterile flask. Dissolve in about 200 ml of fluid A, and mix. Carry out the test
as described under For aqueous solutions.
For antibiotics in packages of 5 g or less. From each of 20 containers, aseptically transfer
about 300 mg of solids into a sterile flask, dissolve in about 200 ml of fluid A and mix, or
constitute as directed on the label of containers and transfer a quantity of liquid or
suspension, equivalent to about 300 mg of solids into a sterile flask, dissolve in about 200 ml
of fluid A, and mix. Carry out the test as described under For aqueous solutions or For oils
and oily solutions, as appropriate.
For sterile devices.
Aseptically pass a sufficient volume of fluid B through each of not less than 20 devices so
that not less than 100 ml is recovered from each device. Collect the fluids in sterile containers
and filter the entire volume through the membrane filter funnel(s) as described under For
aqueous solutions.
In the case of sterile, empty syringes, draw sterile diluent into the barrel thr6ugh the sterile
needle, if attached, or through a sterile needle attached for the purpose of the test and express
the contents into a sterile polling vessel. Proceed as directed above.
For catheters where the inside lumen arid outside surface are required to be sterile, either cut
them into pieces such that the medium is in contact with the entire lumen or full the lumen
with medium and then immerse the intact unit.
Table 3