WALL FOOTING

3
qa(kPa) γs (kN/m3) γ c (kN/m ) DL (kN/m) LL (kN/m) Depth of footing (m) f'c (MPa) fy (MPa) Wall Width (mm)
300 16 23.54 363.96 96.98 1.5 28 480 250
Assumed Initial Thickness (mm)
450
qe (kPa) Area (m2) B (m)
272.61 1.69 1.69
qu (kPa)
350.25
Diameter of Steel bar (mm) Concrete Cover (mm) Assumed Depth (mm)
25 75 362.5
Critical Area (m2)
Width (m) Length (m)
357.5 Per meter strip
Vu Øvc
125213.85 239771.21
Mu < ϴMn therefore t = 450mm is OK.
Steel Requirements
Moment Arm Mu Steel Index, ω
0.720 90.78 0.011
ρ ρ min ρ max
0.0006 0.003 0.018
As (mm2) Nb
1837.875 3.744
Steel Quantity
Main bars Temperature bars
Use 4 pcs - 25 mm diameter As (mm2) Nb
1521.0 19.37
Use 20 pcs - 10 mm diameter