Professional Documents
Culture Documents
Load Calculation For Portal Framed Shed With Wind Asce 7-10
Load Calculation For Portal Framed Shed With Wind Asce 7-10
Purlin Section H B A t
C or Z purlin = 230 mm X 125 mm X 0 mm X 5.0 mm
= 2400 mm2 0.0024 m2
Weight = 18.84 kg/m
= 0.18476 kN/m
Purlin Spacing = 2.5 m
Inclined Half width = 22.9 m
Purlin Numbers = 11
For Full width Purlin Numbers = 22
Total Length of Purlin = 2640.00 m
Total Weight of Purlin = 487.76 kN
Per Unit Area = 0.090 kN/m2
Wind Load:
Wind Perpendicular to Ridge
Windward Wall = 6.6 kN/m
Windward Roof = -7.3 kN/m
Leward Roof = -3.4 kN/m
Leward Wall = -4.7 kN/m
Side Wall = -13.5 kN/m
Wind Parallel to Ridge
Both Roof = -7.3 kN/m
Last Both Rafter = -3.4 kN/m
Windward Wall = 15.75 kN/m
Leward Wall = -6.975 kN/m
Side Wall = -6 kN/m
Considered.
0.4
0.42
0.45
0.47
0.5
0.6