Roof Load Case1- Wind Dir 0,-Cpe Internal Suction

ZONE Name Net Pressure


A Windward Roof -0.73 kN/m2
B Leward Roof -0.34 kN/m2

Wall Load Case1- Wind Dir 0,-Cpe Internal Suction


ZONE Name Net Pressure
MAX(A1,A2,A3) Windward Wall 0..39 kN/m2
B Leward Wall -0.47 kN/m2
C=D Side Wall -0.6 kN/m2
DESIGN WIND LO
ZONE
Roof Load Case2- Wind Dir 0, +Cpe Internal Pressure A
ZONE Name Net Pressure B
A Windward Roof 0.02 kN/m 2
MAX(A1,A2,A3)
B Leward Roof 0.02 kN/m 2
B
C=D
Wall Load Case2- Wind Dir 0,+Cpe Internal Pressure
ZONE Name Net Pressure
MAX(A1,A2,A3) Windward Wall 0.66 kN/m2
B Leward Wall -0.19 kN/m2
C=D Side Wall -0.32 kN/m2
DESIGN WIND LOAD
Name Design Pressure
Windward Roof -0.73 kN/m2 '+ve' sign means load direction inward. Usually outward (-ve value)
Leward Roof -0.34 kN/m 2
'+ve' sign means load direction inward. Usually outward (-ve value)
Windward Wall 0.66 kN/m 2

Leward Wall -0.47 kN/m2


Side Wall -0.6 kN/m2
ward (-ve value)
ward (-ve value)
Roof Load Case3- Wind Dir 90, -Cpe Internal Suction
ZONE Name Net Pressure
Max (A,B,C) Both Roof -0.73 kN/m2
Last Bay D Last Both Roof -0.34 kN/m2

Wall Load Case3- Wind Dir 90, -Cpe Internal Suction


ZONE Name Net Pressure
Max (A1,A2,A3,A4) Windward Wall 0.42 kN/m2
B Leward Wall -0.31 kN/m2
C=D Side Wall -0.6 kN/m2
DESIGN WIND
Roof Load Case4- Wind Dir 90, +Cpe Internal Pressure ZONE
ZONE Name Net Pressure A
Max (A,B,C) Both Roof 0.02 kN/m2 B
Last Bay D Last Both Roof 0.02 kN/m 2
MAX(A1,A2,A3)
B
Wall Load Case4- Wind Dir 90, +Cpe Internal Pressure C=D
ZONE Name Net Pressure
Max (A1,A2,A3,A4) Windward Wall 0.7 kN/m2
B Leward Wall -0.04 kN/m2
C=D Side Wall -0.32 kN/m2
DESIGN WIND LOAD
Name Design Pressure
Both Roof -0.73 kN/m2 '+ve' sign means load direction inward. Usually outward (-ve value)
Last Both Roof -0.34 kN/m2
'+ve' sign means load direction inward. Usually outward (-ve value)
Windward Wall 0.7 kN/m2

Leward Wall -0.31 kN/m2


Side Wall -0.6 kN/m2
ward (-ve value)
ward (-ve value)
Load Calculation for Portal Frame Shed
Shed Length = 120.00 m
Shed Half Width = 22.50 m
Eave Height, he = 7.00 m
Ridge Height, hr = 9.40 m
Slope Angle = 6.09 degree

Live load on Shed roof = 1 kN/m2


Dead Load:
Roof Sheet Thickness = 0.5 mm
Weight = 3.925 kg/m2
= 0.038 kN/m2

Purlin Section H B A t
C or Z purlin = 230 mm X 125 mm X 0 mm X 5.0 mm
= 2400 mm2 0.0024 m2
Weight = 18.84 kg/m
= 0.18476 kN/m
Purlin Spacing = 2.5 m
Inclined Half width = 22.9 m
Purlin Numbers = 11
For Full width Purlin Numbers = 22
Total Length of Purlin = 2640.00 m
Total Weight of Purlin = 487.76 kN
Per Unit Area = 0.090 kN/m2

So, Dead Load From Sheet wt = 0.1288 kN/m2


Collateral Load for Roof = 0.25 kN/m2 If Hanging(HVAC or Other) Load Considered.

Previous Frame distance = 10 m


Next Frame distance = 10 m
Distributory Width for the frame = 10 m
Previous Gable End Post distance = 22.5 m
Next Gable End Post distance = 22.5 m For Gable End Post
Gable End Distributory Width = 22.5 m
Linear Live Load on the frame = 10 kN/m
Linear Dead Load on the frame = 2.898 kN/m
Linear CL on the frame = 2.50 kN/m

Wind Load:
Wind Perpendicular to Ridge
Windward Wall = 6.6 kN/m
Windward Roof = -7.3 kN/m
Leward Roof = -3.4 kN/m
Leward Wall = -4.7 kN/m
Side Wall = -13.5 kN/m
Wind Parallel to Ridge
Both Roof = -7.3 kN/m
Last Both Rafter = -3.4 kN/m
Windward Wall = 15.75 kN/m
Leward Wall = -6.975 kN/m
Side Wall = -6 kN/m
Considered.
0.4
0.42
0.45
0.47
0.5
0.6