Professional Documents
Culture Documents
Qts Gen 0000 GSC 00012 Technical Document Numbering
Qts Gen 0000 GSC 00012 Technical Document Numbering
Form No QTS-GEN-0000-
GSC-00012, A01
Upstream Technical and Vendor Document
2 November 2017
Numbering
* Multiple Sheet Drawings (if two or more sheets are required to complete any particular drawing a sheet number facility is available. This shall
also be utilized to group common drawings (e.g. Cause & Effect matrices, P&ID related to one specific process system number)
This document is the property of Dolphin Energy Ltd. No part of this document may be reproduced or transmitted in any form or by any means, or used for
any purpose other than that which it is specifically furnished without the written consent of Dolphin Energy Ltd. Page 1 of 11
Upstream Technical Services (OMS)
Form No QTS-GEN-0000-
GSC-00012, A01
Upstream Technical and Vendor Document
2 November 2017
Numbering
Downstream Pipeline General Document S Structural (Incl. Weight Control) GA General Arrangement
PLD
Taweelah Receiving Facilities Z Pipelines, Risers and Caissons NP Name Plate/Sign / Engraving
RFT
SM Schematic Diagram
SW Scope of Work
WD Wiring Diagram
This document is the property of Dolphin Energy Ltd. No part of this document may be reproduced or transmitted in any form or by any means, or used for
any purpose other than that which it is specifically furnished without the written consent of Dolphin Energy Ltd. Page 2 of 11
Upstream Technical Services (OMS) Form No QTS-GEN-0000-
GSC-00012, A01
Upstream Technical and Vendor Document Numbering 2 November 2017
Appendix 2
x in the table except unit 200 shall be: 8 Common for two trains only
0 General Purpose/ All trains 9 Common to last two trains
1 For train no 1 Exceptions on EGC Trains: 1,2,3,4,5,6,7,8,9 and common for all trains are 0
2 For train no 2
3 For train no 3
4 For train no 4
104x Dehydration and mercury guard 146x Chemicals storage 011 Gas separation PPJ0 Wellhead / Production Platform Jacket
105x Natural gas liquid recovery 149x Propane loading facilities 012 Free water knock out PPD0 Wellhead / Production Platform Decks (Topsides)
107x NGL fractionation 150x Butane loading facilities 013 Oily water treatment PPD1 Wellhead / Production Platform ESDV Deck
108x Sulphur recovery and tail gas clean-up 151x Off-spec Condensate and DSO storage 020 Power generation PPD2 Wellhead / Production Platform Lower Deck
109x Sour water stripping 152x Sulphur silo and loading facilities 022 Fuel gas PPD3 Wellhead / Production Platform Mezzanine deck
110x KHI Removal Unit 153x Firefighting – Condensate storage area 023 Instrument and Utility air PPD4 Wellhead / Production Platform Upper deck
111x Propane refrigeration 154x Emergency Generation – Condensate Storage Area 024 Nitrogen PPD5 Wellhead / Production Platform Helideck
112x Acid gas enrichment 159x Condensate loading facilities 031 Diesel storage and distribution PPDT Wellhead/Production Platform Temporary Deck
113x CO2 Capture Unit 160x Interconnecting within Plant 032 Fresh water storage and distribution BP00 Bridge Platform Common
114x Propane treatment and drying 161x Control Building 040 Relief and blowdown BPJ0 Bridge Platform Jacket
115x Butane treatment and drying 162x Laboratory 041 Drains BPD0 Bridge Platform Deck
116x Ethane treatment and drying 163x Firefighting building 046 Chemical storage FP00 Flare Platform Common
117x DSO treatment 164x Workshop and Warehouse. 047 Methanol FPJ0 Flare Platform Jacket
118x Condensate treatment 165x Operation building and canteen 063 Handling system FPD0 Flare Platform Deck
120x Electrical generation and distribution in Sub Station 166x HVAC 064 Safety facilities BRG0 Bridges Common
121x Steam generation 167x Electrical distribution in ITR’s 065 Building BRG1 Bridge Wellhead/Production Platform<–>Bridge Platform
122x Fuel gas 170x Interconnecting Offsite 066 HVAC BRG2 Bridge Platform <–> Flare Platform
123x Instrument and service air 171x PCS 071 PCS/PSD PEQR Wellhead / Production Platform Equipment Room
124x Nitrogen 172x PSS 072 ESD/USS/HIPS PSTR Wellhead / Production Platform Shelter
125x Seawater intake and outfall 173x ESD / FGS 073 FGS
126x Seawater desalination 174x Telecom 074 Telecom UPSTREAM SUBSEA PIPELINES
127x Water polishing 175x ICSS Common 075 IT System GAS0 Gas line
133x Injection Water Well 180x 3rd Party Gas Interconnecting 271 PCS/PSD General Non-Geographic Codes
Drawings that encompass more than one system and
272 ESD 0000
134x Tempered Water 182x Instrument and Service Air – Cond storage cannot be geographically located.
135x Industrial Water Treatment for Reuse 273 FGS
140x Flare and Blowdown 274 Telecom
This document is the property of Dolphin Energy Ltd. No part of this document may be reproduced or transmitted in any form or by any means, or used for any purpose other than that which it is specifically furnished without the