Professional Documents
Culture Documents
DS Sheet BRplus r10
DS Sheet BRplus r10
DS Sheet BRplus r10
BiRotor Plus
Positive Displacement Meter
B27X [3”]
B28X [4”]
B29X [6”]
General Dependability
The BiRotor Plus is an extremely accurate dual cased flow There is no metal to metal contact between the rotors
measuring device. It produces via the use of non wetted and the measurement chamber. The meter is therefore
pickoffs a high resolution signal which is directly propor- extremely durable. The rotors are the only moving parts.
tional to the rate of liquid flow through the meter. These Maintenance requirements are the lowest in the industry.
signals can be shaped by a simple internal pre-amplifier for
transmission to ancillary equipment. Affordability
In spite of its superior performance, Brodie can offer the
The BiRotor Plus Meter utilizes the exclusive BiRotor princi- BiRotor Plus at a very competitive price.
ple. There are no sliding, oscillating, or reciprocating parts.
Accuracy Flexibility
The BiRotor Plus meter is the most accurate PD meter in The BiRotor plus meter can be installed either vertically
the market. A linearity of 0.075% and a repeatability of or horizontally. It offers direct pulse output. And it is field
0.02% are better than any other meter in the industry. proven in thousands of installations.
Linearity Repeatability
B27X Standard Rotors (All Sizes):
+/- 0.1% Over Standard Flow Range 0.02% std. Rotors
+/- 0.15% Over Extended Flow Range 0.04% X-Clearance
[Premium accuracy is also available]
B28X and B29X Standard Rotors
+/- 0.075% Over Standard Flow Range Viscosity Range
+/- 0.15% Over Extended Flow Range Standard: 0.2 - 100 cSt
extra clearance rotor version: 100 - 400 cSt
Flow Ranges
To convert pressure drop value to the actual process fluid, Delta PA = Pressure Drop on Actual Fluid in PSI
use the following equation: cPA = Viscosity of Actual Fluid in cP
SGA = Density of Actual Fluid in SG
Delta PA = (cPA)0.25 X (SGA)0.75 X Delta Pm Delta Pm = Pressure Drop on Mineral Spirits
(See Graphs 1 and 2 on Page 4 for Reference)
Pressure Drop
4” and 6” BiRotor Plus
3” BiRotor Plus
Approvals
Environmental Electromagnetic Emis- Hazardous Area Weights and Measures Pressure Equipment
sions & Immunity
NEMA 4X CE European Union (EN CSA (United States and NTEP Under the EU Pressure
61326) Canada) Equipment Directive
Class 1, Division 1, Group 97/23/EC
C, and D Certificate:
2142875 221162
standard pick off: -4°F to
167°F, -20°C to 75°C
hight temp pickoff: 14°F
to 230°F, -10°C to 110°C
Type 4X OIML R117-1 Class E2 ATEX Measurement Canada Rated as SEP for ANSI
CE 0359 II 2 G Ex d IIB 150# and PN 16 versions
T6…T4 Certificate: ITS
08 ATEX 15842X
standard pick-off: -20°F
to 167°F, -29°C to 75°C
high temp pickoff: -20°F
to 230°F, -29°C to 110°C
IP 65 MID Class E2 GOST OIML Rated as CAT 2 for 300#
-20°F to 167°F, -29°C to and PN40 versions,
75°C
OIML R117-1 Class H3 FCC 47 CFR Part 15 IEC Ex MID Canadian Registration:
Ex d IIB T6 – T4 Gb All Provinces
Certificate: IEC Ex ITS
08.0021X
standard pick-off: -20°F
to 140°F, -29°C to 60°C
high temp pickoff: -20°F
to 230°F, -29°C to 110°C
ICES-003 Issue 4 GOST [3” and 4”]
China
Australia NMI
Meter Housing: ASTM A 216 WCB End plates and body: A 356 T6 Cast Aluminium
ASTM A 516 GR 70 Rotors: ALCO 319 Cast Aluminium Hard Coat
Connection Flanges: ASTM A 105 Carbon Steel anodized
Rotor shafts: 17-4 PH Stainless Steel
Sensor Housing: ASTM A 479 Timing gears 3”: 17-4 PH Stainless Steel
304 Stainless Steel Timing gears 4, 6”: 17-4 PH Stainless Steel
Bearings: Hybrid Ceramic
Elastomers: Low swell Nitrile, Viton F®,
or Fluoro Silicon are standard
UMB Housing: A356 T6 Cast Aluminium [non wetted
component]