Professional Documents
Culture Documents
Silo Ut Inspection Report
Silo Ut Inspection Report
INSPECTION REPORT
C-4 C-3
C-2
` C-1
2
DEFECT LOCATIONS:
1. DEFECT DEPTH: 7.1, 8.2, 9.9 & 12.1 MM
DEFFECT LENGTH: 210 MM
DEFECT TYPE: LACK OF FUSION
INSPECTED BY WITNESSED BY
TUV SUD SOUTH ASIA(P) Ltd. KPCL
The above defects identified and again UT will be conduct after repairs.