Professional Documents
Culture Documents
Protection Relay
Protection Relay
Protection Relay
Power Factor Control or Monitoring Relays Page Motor Protection Relay Page
5
PRODUCT DESIGN STANDARDS
BACK 5/1
TECHNICAL DATA
THREE PHASE OVER CURRENT AND EARTH FAULT RELAYS
✦ Display of Currents, settings, Trip data & Trip history for analysis & trouble shooting.
✦ Built in Self Supervision & Self testing feature to ensure continuous reliability.
✦ Separate Indication for power ON & Programming mode or relay fault.
✦ Separate fault indication.
✦ In MC61C - Communication with Computer & breaker control through RS 485 Port.
✦ Four User Programmable Output relays.
5
Description 3 Phase O/C + E/F 3 Phase O/C + E/F + Highset 3 Phase O/C + E/F + Highset
Communication and
breaker control
Functions Available Lowset O/C -ls Lowset O/C -ls Lowset O/C -ls
Lowset E/F -Os Highset O/C -lhs Highset O/C -lhs
Lowset E/F -Os Lowset E/F -Os
Highset E/F -Ohs Highset E/F -Ohs
Settings O/C ls = 20-200% Step 5% O/C ls = 20-200% Step 5% O/C ls = 20-200% Step 5%
E/F Os = 5-80% Step 5% E/F Os = 5-80% Step 5% E/F Os = 5-80% Step 5%
HS O/C = (0.2 to 40) x In step of - HS O/C = (0.2 to 40) x In step of - HS O/C = (0.2 to 40) x In step of -
0.2 In or disable 0.2 In or disable 0.2 In or disable
HS E/F = (0.1 to 20) x On step of - HS E/F = (0.1 to 20) x On step of - HS E/F = (0.1 to 20) x On step of -
0.1 On or disable 0.1 On or disable 0.1 On or disable
Time Characteristics available - Time Characteristics available - Time Characteristics available -
NI, VI, EI, or Definite Time NI, VI, EI, or Definite Time NI, VI, EI, or Definite Time
TMS 0.1 - 1.6 Step 0.05 TMS 0.1 - 1.6 Step 0.05 TMS 0.1 - 1.6 Step 0.05
Other Features Site selectable Trip time Char. Site selectable Trip time Char. HS delay:0.1-2 Sec step 0.01 Sec. or Inst.
Highset can be disabled RS 485 Communication
Display of Currents, Trip count Display of Currents, Trip count Breaker control
Self supervision feature Self supervision feature Auto doubling of highset, Relay co-ordination
Output Contact 1 N/O contact for self suprvn 1 N/O contact for self suprvn 1 N/O contact for self suprvn
Dim W x H x D in mm 121 x 158 x 224 121 x 158 x 224 121 x 158 x 224
5/2
BACK
WIRING DIAGRAM
THREE PHASE OVER CURRENT AND EARTH FAULT RELAYS
MC31A
MC61A
MC61C
5/3
BACK
ORDERING INFORMATION
THREE PHASE OVER CURRENT AND EARTH FAULT RELAYS
5/4 BACK
TECHNICAL DATA
CURRENT SENSING RELAYS
Single Phase Over current / Earth fault Relay
Sensitive E/F Relay and Instantaneous Current Relay
✦ Easy Setting through front panel DIP Switches.
✦ Indication for Power ON and trip status.
✦ Test feature - helps maintenance.
✦ Compact, Light weight helps in reducing panel size & thickness.
5
Description 1 Ph O/C or E/F 1 Ph Sensitive E/F Instantaneous current relay
Other Features Site selectable Trip time Char. Site selectable Trip time Char. Relay testing Possible by ext.24V Supply
Highset can be disabled Highset can be disabled Flag indication / LED indication
Harmonic rejection
Output Contact 2 C/O Contacts (S/R) 2 C/O Contacts (S/R) 2 C/O Contacts (S/R)
5/5
BACK
WIRING DIAGRAM
CURRENT SENSING RELAYS
MC11A
ME11A
SC14S
5/6
BACK
ORDERING INFORMATION
CURRENT SENSING RELAYS
5/7
BACK
TECHNICAL DATA
NEUTRAL DISPLACEMENT RELAY, GENERATOR LOAD
SHARING RELAY, UNDER VOLTAGE OR OVER VOLTAGE RELAY
✦ Easy Setting through front panel DIP Switches.
✦ LED indication for Power ON and trip status.
✦ Test feature - helps maintenance.
✦ Compact, Light weight helps in reducing panel size & thickness.
5
Description Neutral Displacement Generator Load Sharing 1 Ph U/V OR O/V
Device Code 59 Vo 95 27 OR 59
Functions Available Voltage relay for E/F Protection Active / Reactive power selection Lowset U/V -Vs
of generator earthed thro Over Power alarm Highset U/V -Vhs OR
neutral earthing transformer Load Sharing Lowset O/V -Vs
Frequency control Highset O/V -Vhs
Other Features LED indication for power ON LED indication Site selectable U/V OR O/V
time characteristics, trip Site selectable Trip time char.
Test feature Highset can be disabled
Third harmonics rejection 26db
Output Contact 1No+2 C/O Contacts (S/R) 3 N/O 2 C/O Contacts (S/R)
5/8 BACK
WIRING DIAGRAM
NEUTRAL DISPLACEMENT RELAY, GENERATOR LOAD
SHARING RELAY, UNDER VOLTAGE OR OVER VOLTAGE RELAY
MND11
RRS
MV11
5/9
BACK
ORDERING INFORMATION
NEUTRAL DISPLACEMENT RELAY, GENERATOR LOAD
SHARING RELAY, UNDER VOLTAGE OR OVER VOLTAGE RELAY
Model Description Catalogue No.
5
Catalogue No. Selection Guide for MV11A
5/10
BACK
TECHNICAL DATA
SECONDARY RELAYS
Trip Circuit Supervision Relay
Timer Relay and PT Fuse Failure Relay
Functions Available Post Close Supervision Programmable as Delay on 3 Phase PT fuse failure
Pre Close Supervision Pick up or Drop off
Settings Trip coil supply 110 - 220V AC 15 - 999 mS step 1 mS Not applicable
OR 24 - 48 - 110 - 220V DC 1 - 9.99 S step 10mS
Operation time 500+/-100mS 10 - 99.9 S step 100mS Operation time 7mS
Reset time < 150 mS 100 - 999 S step 1S
Other Features Same Relay for all Rating Password protection available LED Indication for each phase
Trip supply U/V indication Contacts programmable Relay trip status
CB ON/OFF status indication as S/R or H/R Self powered
High speed operation
Output Contacts 2 C/O Contacts (S/R) 2 N/O + 2 N/C Per timer 2 C/O Contacts (S/R)
BACK 5/11
WIRING DIAGRAM
SECONDARY RELAYS
TCS01
MTMO1
PTFO3
5/12
BACK
ORDERING INFORMATION
SECONDARY RELAYS
BACK 5/13
TECHNICAL DATA
POWER FACTOR CONTROL AND MONITORING RELAYS
Power Factor Controller Relay and
Voltage & Power Factor Monitoring Relay
Description Power Factor Controller Power Factor Controller Voltage / Power Factor monitor
Device Code
Functions Available Automatic PF controller Automatic PF controller U/V, O/V trip and leading PF alarm
Can control upto- Can control upto-
8 Capacitor Banks 14 Capacitor Banks
Settings PF : 0.8 Lag - 0.95 Lead PF : 0.8 Lag - 0.95 Lead U/V 75% to 90% step 1%
Switching time 10-20-40-60 S Switching time 10-20-40-60 S OV 105% to 120% step 1%
Threshold reactive current Threshold reactive current
setting 0.5 - 1A reactive setting 0.5 - 1A reactive leading PF alarm time 20 Sec.
Capacitor Bank Selection- Capacitor Bank Selection- U/V - O/V trip time 10 Sec.
4-5-6-7-8 Banks 4-5-6-7-8-10-12-14 Banks
Burden on PT 10 VA 10 VA 15 VA
Dim W x H x D in mm 144 x 144 x 110 144 x 144 x 110 144 x 144 x 110
5/14 BACK
WIRING DIAGRAM
POWER FACTOR CONTROL & MONITORING RELAYS
PFC14
PFC8
MVP01
BACK 5/15
ORDERING INFORMATION
POWER FACTOR CONTROL & MONITORING RELAYS
5/16
BACK
TECHNICAL DATA
MOTOR PROTECTION RELAY
✦ Display of various parameters, trip count and trip data on 8 digit alphanumeric display.
✦ Separate LEDs for various fault indication.
✦ Four user programmable output relays.
✦ Built in self supervision & self testing feature helps maintenance.
✦ Easy operation by 5 push buttons.
✦ RS 485 port for serial communication with MSCON user friendly software.
Model MM30
Device Code 49, 51lr, 46, 37, 50/51, 64, sTnO, LTR
Design Numeric
Construction Drawout
BACK 5/17
WIRING DIAGRAM
MOTOR PROTECTION RELAY
MM30
5/18
BACK
ORDERING INFORMATION
MOTOR PROTECTION RELAY
5/19
BACK
TECHNICAL DATA
GENERATOR PROTECTION RELAYS
Multifunction Generator Protection Relays and
Percentage Biased Generator Differential Relay
✦ Display of various parameters, trip count & trip data on 8 digit alphanumeric display.
✦ Separate LEDs for various fault indication.
✦ Four user programmable output relays.
✦ Built in self supervision & self testing feature help maintenance
✦ Easy operation by 5 push buttons.
✦ RS 485 port for serial communication with MSCOM User friendly software.
Device Code 50/51V, 49,46,27,59,81,40,32,37 50/51, 46, 64S, 40, 32 87, 50/51, 50LBB, 64S / 87N
Functions Available Voltage rest. O/C Highset Lowset O/C Generator Differential
Trip time char. NI, Def time Highset O/C Bias % with dual adjustable slope
Thermal Image Stator E/F Over Current
Lowset Negative sequence Negative Sequence Stator E/F
Highset Negative sequence Reverse Power CB Failure protection
Under voltage, Over frequency
Loss of field, Reverse Power
Low forward power,
CB Failure protection
Burden on CT 0.2 VA for 5A, 0.01 VA for 1A 0.2 VA for 5A, 0.01 VA for 1A 0.2 VA for 5A, 0.01 VA for 1A
Output Contacts 4 C/O, S/R or H/R or Time del 4 C/O, S/R or H/R or Time del 4 C/O, S/R or H/R or Time del
1 C/O for self supervision 1 C/O for self supervision 1 C/O for self supervision
Dim W x H x D in mm 121 x 158 x 224 121 x 158 x 224 121 x 158 x 224
5/20
BACK
WIRING DIAGRAM
GENERATOR PROTECTION RELAYS
IM3GV
IM30G
MD32G
5/21
BACK
ORDERING INFORMATION
GENERATOR PROTECTION RELAYS
5/22
BACK
TECHNICAL DATA
SYNCHRONISING RELAYS
Generator Synchronising /
Synchrocheck relays
✦ Display of various parameters, event count & event data on 8 digit alphanumeric display.
✦ Separate LEDs for various fault indication.
✦ Four user programmable output relays.
✦ Built in self supervision & self testing feature help maintenance.
✦ Easy operation by 5 push buttons.
✦ RS 485 port for serial communication with MSCOM User friendly software.
Device Code 25 25
5/23
BACK
WIRING DIAGRAM
SYNCHRONISING RELAYS
SPM21
SCM21
5/24 BACK
ORDERING INFORMATION
SYNCHRONISING RELAYS
5/25
BACK
TECHNICAL DATA
VOLTAGE / FREQUENCY RELAYS, DIRECTIONAL O/C, E/F RELAY
3 Phase voltage / frequency and Load shedding Relay
3 Phase voltage / frequency and zero sequence voltage Relay
✦ Display of various parameters, trip count & trip data on 8 digit alphanumeric display.
✦ Separate LEDs for various fault indication.
✦ Four user programmable output relays.
✦ Built in self supervision & self testing feature help maintenance.
✦ Easy operation by 5 push buttons.
✦ RS 485 port for serial communication with MSCOM User friendly software.
Description 3 Ph Voltage & Freq. Relay 3 Ph Voltage & Freq. Relay 3 Ph Dir O/C & E/F + Highset
Device Code 81, 27, 59, df/dt, de/dt 81, 27, 59, V/Hz, 59d, 59s, 59Uo 50/67 RYBN, 50 LBB
Functions Available Frequency-4 stages selectable Over exitation-2 stages Low Set Dir O/C
as under or over or under/over Frequency-2 stages selectable Highset Dir O/C
Voltages - 2 stages selectable as under or over or under/over Low Set Dir E/F
Rate of change of frequency Voltages - 2 stages selectable Trip time Char : NI, VI, EI, Def time
protection df / dt - 2 Stages as under or over CB Failure Function
Blocking function Zero Sequence - 2 Stages MTA Setting = 0-359°
Blocking function 1A or 5A site selectable
Rating 100 - 125V PT input 100 - 125V PT input 100 - 125V PT input
Burden on CT Not applicable Not applicable 0.2 VA for 5A, 0.01 VA for 1A
Output Contacts 4 C/O, S/R or H/R or Time del 4 C/O, S/R or H/R or Time del 4 C/O, S/R or H/R or Time del
1 C/O for self supervision 1 C/O for self supervision 1 C/O for self supervision
Dim W x H x D in mm 121 x 158 x 224 121 x 158 x 224 121 x 158 x 224
5/26
BACK
WIRING DIAGRAM
VOLTAGE / FREQUENCY RELAYS, DIRECTIONAL O/C, E/F RELAY
UFD34
UM30A
DM30
5/27
BACK
ORDERING INFORMATION
VOLTAGE / FREQUENCY RELAYS, DIRECTIONAL O/C, E/F RELAY
5/28
BACK
TECHNICAL DATA
TRANSFORMER PROTECTION RELAY, CAPACITOR BANK PROTECTION RELAY
Percentage Biased Transformer Differential Relay
3 Phase Thermal + Over Current + Earth Fault Relay for transformer protection
✦ Display of various parameters, trip count & trip data on 8 digit alphanumeric display.
✦ Separate LEDs for various fault indication.
✦ Four user programmable output relays.
✦ Built in self supervision & self testing feature help maintenance.
✦ Easy operation by 5 push buttons.
✦ RS 485 port for serial communication with MSCOM User friendly software.
Device Code 87 RYB, 87N 50/51 RYBN, 49, 46, 12t 51/51 RYBN, 46, 37 1o
Burden on CT 0.2 VA for 5A, 0.01 VA for 1A 0.2 VA for 5A, 0.01 VA for 1A
Output Contacts 5 C/O, S/R or H/R or Time del 5 C/O, S/R or H/R or Time del 2 C/O contacts, S/R or H/R
5/29
BACK
WIRING DIAGRAM
TRANSFORMER PROTECTION RELAYS, CAPACITOR BANK PROTECTION RELAY
MD32T
IM30T
DIN30C
5/30
BACK
ORDERING INFORMATION
TRANSFORMER PROTECTION RELAYS, CAPACITOR BANK PROTECTION RELAY
IM30T 3 Phase O/C and E/F Relay for Transformer 20-110V ED30TAXX000
IM30T 3 Phase O/C and E/F Relay for Transformer 88-264V ED30TBXX000
BACK 5/31
TECHNICAL DATA
CONTROL & SUPERVISION RELAYS
Power Management Relay
Multifunction 3 Phase Measuring Instrument
✦ Display of various parameters, event count & event data on 8 digit alphanumeric display.
✦ Separate LEDs for various fault indication.
✦ Four user programmable output relays.
✦ Built in self supervision & self testing feature help maintenance.
✦ Easy operation by 5 push buttons.
✦ RS 485 port for serial communication with MSCOM User friendly software.
Burden on CT 0.2 VA for 5A, 0.01 VA for 1A 0.2 VA for 5A, 0.01 VA for 1A
5/32
BACK
WIRING DIAGRAM
CONTROL AND SUPERVISION RELAYS
MW33
MU30
5/33
BACK
ORDERING INFORMATION
CONTROL AND SUPERVISION RELAYS
5/34
BACK
TECHNICAL DATA
REVERSE POWER RELAY
Model MRP11
Construction Drawout
5/35
BACK
WIRING DIAGRAM
ORDERING INFORMATION
5/36
BACK
ORDERING INFORMATION
OTHER RELAYS
5/37
BACK