Allowable Drilling Torque: Calculations 30,577 4.855 21.733 4.154 0.362 0.2
Allowable Drilling Torque: Calculations 30,577 4.855 21.733 4.154 0.362 0.2
xls MITCHELL ENGINEERING PROGRAMS
COPYRIGHT 1990 MITCHELL ENGINEERING, PO BOX 1492. GOLDEN, CO, 80402, USA (303) 273 3744
CALCULATIONS
30,577 TORSIONAL STRENGTH OF WALL WITH API FORMULA; lb-ft
4.855 WORN OD OF DRILLPIPE; in
21.733 POLAR MOMENT OF INERTIA OF WORN DRILLPIPE; in^4
4.154 WORN AREA OF DRILLPIPE; in^2
0.362 NOMINAL WALL THICKNESS OF THE DRILLPIPE; in
0.2 WEAR FRACTION; fr
COMPUTATIONS:
1. COMPUTES TORSIONAL STRENGTH OF PIPE UNDER LOAD
2. COMPARES PIPE, TOOL JOINT, MAKE-UP TORQUE