Download as pdf
Download as pdf
You are on page 1of 206
Asociatia de Standardizare din Romania, GENERAL INSTAL COMP. S.R.L., 02/42/2015, Titty Aprobare Corespondenta Ay CS 13.20.20 Standard Roman Noiembrie 2015 Instalatii fixe de lupta impotriva incendiului Sisteme automate de si sprinkler Dimensionare, instalare gi intretinere Fixed firefighting systems - Automatic sprinkler systems - Design, instalation and maintenance Installations fixes de lutte contre incendie - Systémes dextinction automatique «du type sprinkleur - Conception, instalation ef maintenance Aprobat de Directorul General al ASRO la 27 noiembrie 2015 Standardul european EN 12845:2015 are statutul unui standard roman Inlocuieste SR EN 12845+A2:2009 Data publicarii versiunii romano: - ‘Acest standard este identic cu standardul european EN 12845:2015 © ASRO ASOCIATIA DE STANDARDIZARE DIN ROMANIA © Str, Mendeleev nr, 21-25, cod 010362, Bucuresti , G www.asro.t0 FReproducerea sau utiizarea inlegrala sau paral a prezentulii standard tn orice publcati si prin rice procedeu (electronic, mecanic,fotocepiere, mirofimars elt) oste Interest dacd nu exsta acordul srs prealabi al ASRO. Ref. SR EN 12646:2015 Ea a ‘Asociatia de Standardizare din Romania, GENERAL INSTAL COMP. S.R.L,, 02/12/2015 EUROPEAN STANDARD EN 12845 NORME EUROPEENNE EUROPAISCHE NORM June 2018 ee les 13,220.20 ‘Supersedes EN 12845:2004+A2:2009 English Version Fixed firefighting systems - Automatic sprinkler systems - Design, installation and maintenance Installations fixes deltte conte incendie - Systémes Ortsteste Brandbekémpfungsantagen - Automatische extinction automatique du typa sprinkleur- Conception, ‘Sprinkteaniagen - Planung, Installation und Instandheltung instalation et maintenance ‘This European Standard was approved by CEN en 20 December 2014 CEN members are bound to comply with the CENICENELEC intemal Regultions which stipulate the conditions forging this European Standard the statis of a national standard without any alteration. Up-to-date ists and bibliographical oferencas concorning such nations Standards may be obtained on epplcation tothe CEN-CENELEG Management Cantto oro any CEN member. ‘This European Stendard exists in three offical versions (Engish, French, German. A version inary other language made by translation Under the responsibilty of a CEN member Into ts own language and notifed to the CEN-CENELEC Management Contre has the same ‘status asthe oficial versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czach Republic, Denmark, Estonia Finland, Former Yugesiav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Ral Latvia, itwania, Luxembourg, Mata, Netherlands, Norway, Poland, Portugal, Romania, Slovakie, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingeem, a! [EUROPEAN COMMITTEE FOR STANDARDIZATION COMITE EUROPEEN DE NORMALISATION BUROPAISCHES KOM(TEE FOR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, 8.1000 Brussels, ©2015 CEN _Allights of exploitation in any form and by any means reserved Ret, No, EN 12845:2015 € \Werldnige for CEN national Members, Asociatia de Standardizare din Romania, GENERAL INSTAL COMP. S.R.L., 02/12/2015 Contents Page Foreword, Introduction... 1 Scope. 2 Normative references... 3 Terms and definitions . 4 Contract planning and documentation. 844 81.3 Preliminary or estimating stage Design stage. ‘Summary schedule. Installation layout drawings ..... Water supply Extent of sprinkler protection. Buildings and areas to be protecte: General Permitted exceptions within a building Necessary exceptions... Storage in the open ai Fire resistant separation .. Protection of concealed spaces. Height difference between the highest and lowest sprinklers. Classification of occupancies and fire hazards General Hazard classes. General Light Hazard ~ LH... Ordinary Hazard ~ OH .. High Hazard — HH. Storage, General Storage Configuration... Hydraulic design criteria.. LH, OH and HHI High Hazard Storage — HHS. General Ceiling or roof protection only .. Intermediate level in-rack s} Pressure and flow requi LH and OH systems. : HHP and HHS systems without in-rack sprinklers... klers Water supplies . General, Duration Continuity... Frost protection ..

You might also like