Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 8

Project Commercial Building Date

Description Preliminary Footing Design By


Chkd

FOOTING F3 c3
564 564 kn

26 29 kn-m

Col Size 0.3 x

t = 0.5

d = 0.465 Critical Sections

2.2 m
d/2 = 0.2325

2 m

Step 1 - Check Soil Pressure

Pressure from Self Weight of Ftg = 25 Kpa

Net Allowable Soil Pressure = 299 Kpa

e = 0.049 < L 0.366667


6
P My
q= ±
A I
P = 1128 = 256.4 Kpa
A 4.4

My = y = 1.1 m
I I = 1.47 m4

= 41.25 Kpa

q = 297.6 Kpa OK
q = 215.1 Kpa OK

F1
Project Commercial Building Date
Description Preliminary Footing Design By
Chkd

FOOTING F3 c3

Step 2 - Check Thickness

Check Punching Shear

Tributary Area for


Punching Shear

2.2 m
d/2 = 0.2325

2 m

Pressure = 128.18 Kpa


Trib. Area = 3.81 m2
Shear = 488.98 KN

Punching Shear Capacity of Footing

V RD =0 . 5 f ctd ( 1+50 ρ ) ud
Assumptions:
As = f 20 @ 200
Critical Section Occurs at d/2 (Note: EBCS say critical section is at
1.5d, which contradicts all text books
Therefore, use d/2)

fctd = 1133 kpa


d = 0.465 m
r = 0.00333
u = 3.06

= 940.4183 KN OK

F1
Project Commercial Building Date
Description Preliminary Footing Design By
Chkd

FOOTING F3 c3

Check one-way Action d = 0.465

Tributary Area for


one-way action

2.2 m

2 m

Calculate Shear @ Critical Section

215.1

297.6 Kpa

Critical Section From Edge of Footing is = 0.385 m


Pressure At Critical Section is = 281.7324 Kpa
Shear At Critical Section is = 248.6964 Kn

Shear Capacity of Section

V c=0 .25 f ctd k 1 k 2 b w d


fctd = 1133
K1 = (1+50r)
r = 0.00333
= 1.17
d = 0.465

F1
Project Commercial Building Date
Description Preliminary Footing Design By
Chkd

FOOTING F3 c3
K2 = 1.6 -d = 1.135
bw = 2.20

= 383.70 Kn OK

Step 3 - Design for Flexure

215.1

297.6

Critical Section For Moment

Critical Section From Edge of Footing is = 0.85


Pressure At Critical Section is = 262.55 Kpa
Moment At Critical Section is = 103.2908 Kn - m/m

Calculate Reinforcement

ρreq =
1
m[ √
1− 1−
2 mR n
f yd ] ; m=
f
f
yd

cd
; Rn =
Mu
bd 2

fcd = 13600 Kpa


fyd = 347826.00 Kpa
d = 0.465 m
b = 1.00 m

m = 25.58
Rn = 477.70

F1
Project Commercial Building Date
Description Preliminary Footing Design By
Chkd

FOOTING F3 c3
= 0.0013984 use

As = 0.00065 = 5.750 Dia 12


Use f 12 @ 150

F1
Project Commercial Building Date Jul-05
Description Preliminary Footing Design By
Chkd

FOOTING F3 c3
564 564 kn

26 29 kn-m

Col Size 0.3 x 0.3

t = 0.5

d = 0.465 Critical Sections

2.2 m
d/2 = 0.2325

2 m

Step 1 - Check Soil Pressure

Pressure from Self Weight of Ftg = 25 Kpa

Net Allowable Soil Pressure = 299 Kpa

e = 0.049 < L 0.366667


6
P My
q= ±
A I
P = 1128 = 256.4 Kpa
A 4.4

My = y = 1.1 m
I I = 1.47 m4

= 41.25 Kpa

q = 297.6 Kpa OK
q = 215.1 Kpa OK

F1
Project Commercial Building Date Jul-05
Description Preliminary Footing Design By
Chkd

FOOTING F3 c3
K2 = 1.6 -d = 1.135
bw = 2.20

= 383.70 Kn OK

Step 3 - Design for Flexure

215.1

297.6

Critical Section For Moment

Critical Section From Edge of Footing is = 0.85


Pressure At Critical Section is = 262.55 Kpa
Moment At Critical Section is = 103.2908 Kn - m/m

Calculate Reinforcement

ρreq =
1
m[ √
1− 1−
2 mR n
f yd ] ; m=
f
f
yd

cd
; Rn =
Mu
bd 2

fcd = 13600 Kpa


fyd = 347826.00 Kpa
d = 0.465 m
b = 1.00 m

m = 25.58
Rn = 477.70

F1
Project Commercial Building Date Jul-05
Description Preliminary Footing Design By
Chkd

FOOTING F3 c3
= 0.0013984 use

As = 0.00065 = 5.750 Dia 12 bars


Use f 12 @ 150

F1