MCGM - Bhandup WWTF: Design Calculations for Combined Haeting & Power Unit

Sl. No: Item Specifcation Quantity


1 Air Blower Capacity : 220 Nm3/hr 3w+3S
Head : 2000 mm WC
Motor: Flame Proof & VFD comaptible

2 De-humidifier Capacity : 220 Nm3/hr 4w+1s


Auxiliary Unit: Chilled Water Pump/ Circulation Pump,
Water Chiilers, Heat Exchangers, Chiiled Water Tanks, Field
Instruments & Control Panel, Condensate Removal Unit

3 Flare System Capacity : 220 Nm3/hr 4w+1s


Line Size: 10 m for each stream
Height : 7m
Minimum Gas Inlet Pressure : 15-30 mbar
Flare Burner : With winshield, mixing tube, flame arresrer,
Pressue Transmitter & Control Panel

4 Scrubber Capacity : 220 Nm3/hr 4w+1s


Inlet H2 S Level: 3000 ppm
Outlet H2 S Level: 50 ppm
Auxiliary Unit: Venturi Scrubber Tank & Column, Chemical
Scrubber Tank & Column (1st& 2nd stage), Water
Circulation Pump (1W+1SB for each stream), Chemical
Circulation Pump (1W+1SB for each stream),Chemical
Dozing Pump (1W+1SB for each stream), Chemical Mixing
and Dozing Tank (1W+1SB for each stream), Field
Instrument & Control Panel