2 XCSDMx7x Magnetic Switches & XPSAF Unit Wiring Diagram

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

XCSDM*7* switch + XPSAF unit

Wiring diagrams using XPSAF5130(P) unit


How to propose a solution PL e cat 4 with 2
switches (CSCS)

Simply easy!TM
XCSDMP/C/R7* switch + XPSAF unit
● Wiring diagram in the XPSAF association
● 1 alone switch in PL e category 4 according to ISO 13849-1 standard

Telemecanique Sensors - Technical Support – September 30th, 2015 2


XCSDMP/C/R7* switch + XPSAF unit
● Wiring diagram in the XPSAF association
● 2 or 3 switches in PL d category 3 according to ISO 13849-1 standard and to the ISO
14119 oct. 2013 (fault masking, refer to the PR ISO/TR 24119). 2 switches with led not compatible.

Telemecanique Sensors - Technical Support – September 30th, 2015 3


Alternative solution to reach PLe cat. 4
● XPSDMB/E + XCSDM*5* magnetic switches
● Please refer to the following CSCS (certified safety chain solution) diagram,
promoting the XPSDMB or XPSDME unit. By connecting only 1 switch per
input group, the maximum safety level PL e category 4 can be declared.

Telemecanique Sensors - Technical Support – September 30th, 2015 4