ELEFIR-EN REPORT

Project name: URRETXINDORRA IKASTOLA


Date: 17/12/2016
gM0 = 1.05
gM,fi = 1.00

Temperature evaluated using interpolation on the table 3.1 from EN 1993-1-2.

PROFILE

HE 280 B (Class 1)

h = 280 mm
b = 280 mm
tw = 10.5 mm
tf = 18 mm
r = 24 mm
A = 13140 mm²
P = 1.62 m²/m

iy = 121.1 mm
iz = 70.9 mm
Wel,y = 1376450 mm³
Wpl,y = 1534000 mm³
Iy = 192700000 mm4
Wel,z = 471000 mm³
Wpl,z = 717600 mm³
Iz = 65950000 mm4
It = 1437000 mm4
Iw = 1130000000000 mm6

STEEL

Carbon steel, S275

Young modulus: 210 GPa

ELEMENT SUBMITTED TO BENDING AND COMPRESSION

Critical temperature function of the loads

System length: Ly = 1550 mm; Lz = 1550 mm


Buckling coefficients: ly,fi/Ly= 1; lz,fi/Lz= 1
Design axial compression load: Nb,fi,Ed = 12.402 kN

About major axis - Moments due to in-plane lateral loads and end moments
M1 = -43.515 kNm
M2 = 8.11 kNm
MQ = 0.309321875 kNm
Mmax = 43.515 kNm
Distributed load: q = 1.03 kN/m

Lateral torsional buckling is allowed.

LATERAL TORSIONAL BUCKLING


Point of load application: Shear centre
Load: Transverse load
Bending moment diagram: End moments and uniform load
Bending moment ratio: y = -0.186
Effective length factor: kz = 1.0; kw = 1.0
Load: q = 1.03 kN/m
Moment: Mfi,Ed = 43.515 kNm
Length between lateral restraints: 1550 mm
C1 = 1.957
C2 = 0.004
Mcr = 15417.653 kNm

RESULTS

Buckling resistance of the element


Critical temperature: 788.5 ºC (Reduction factor, ky,q: 0.124)

The critical temperature was conditioned by the interaction formula (4.21b) from EN 1993-1-2.

Resistance of the cross-section


Critical temperature: 805.9 ºC (Reduction factor, ky,q: 0.107)

Critical temperature used in the next calculations: 788.5 ºC