This pump's basic function is to pump hot or cold Maximum operating pressure
water, water with glycol or other low viscosity - Pump casing: 25 bars
fluids that contain no mineral oil, solid or abrasive - Maximum suction pressure: 10 bars
substances, or materials having long fibres. The Temperature range
manufacturer's approval is required for use to - Liquid temperatures: -30 to +120 °C
pump corrosive chemicals. - Ambient temperature: +40 °C
CAUTION! Risk of explosion! Electrical data
Do not use this pump to handle flammable or - Motor efficiency: IE2 for 3-phase motor accor-
explosive liquids. ding to IEC 60034-30
- Motor Protection index: IP 55
4.1 Applications areas - Insulation class: F
- water distribution and boosting installations, - Frequency: see data plate
- industrial circulation systems, - Electrical voltage: see data plate
- process fluids,
- cooling water circuits, Outline and pipe dimensions (Fig. 4).
- fire-fighting and washing stations, dimensions (mm)
- watering installations, etc. Types
A B C D E F G H J
PN16 160 204 50 Rp1 2xM10
5. Technical data HELIX V 2../4..
PN25 175 250 75 DN25 4xM12
5.1 Pump designation 100 215 180 4xM12
PN16 160 204 50 Rp11/4 2xM10
HELIX V 6..
5.1.1 Type key for pump with motor PN25 175 250 75 DN32 4xM16
PN16 250 Rp11/2 2xM12
HELIX V 16 04 - x / 16 / x / x / xxx-xx+x / xxxx / A HELIX V 10.. 80
PN25 280 DN40 4xM16
130 255 215 190 4xM12
Pump family PN16 250 Rp2 2xM12
Flow rate (m3/h) HELIX V 16.. 90
PN25 300 DN50 4xM16
Number of impellers
Pump material code 5.3 Scope of Supply
Max. working pressure • Multistage pump.
Seal type code • Installation and operating instructions.
Option code (if any) • Counterflange + screws and o’rings for PN16
configuration.
Motor electric voltage
• Counterflange bolts, nuts and gaskets for PN25
Motor frequency configuration.
Terminal box position
(if not default position) 5.4 Accessories
Variants code (if any) Original accessories are available for HELIX range:
Manufacturer technical index
Designation article N°
5.1.2 bare-shaft pump (without motor) 2x oval counterflanges in stainless steel 1.4301 (PN16 – 1”) 4016168
2x round counterflanges in stainless steel 1.4404 (PN25 – DN25) 4016165
HELIX V 16 04 - x / 16 / x / x / xx - xxxxxxx/ xxxx / A 2x round counterflanges in steel (PN25 – DN25) 4016162
Pump family 2x oval counterflanges in stainless steel 1.4301 (PN16 – 1” ) 1/4
4016169
Flow rate (m3/h) 2x round counterflanges in stainless steel 1.4404 (PN25 – DN32) 4016166
Number of impellers 2x round counterflanges in steel (PN25 – DN32) 4016163
Pump material code 2x oval counterflanges in stainless steel 1.4301 (PN16 – 1” ) 1/2
4016170
Max. working pressure 2x round counterflanges in stainless steel 1.4404 (PN25 – DN40) 4016167
Seal type code
2x round counterflanges in steel (PN25 – DN40) 4016164
Option code (if any)
2x oval counterflanges in stainless steel 1.4301 (PN16 – 2”) 4055063
Motor frequency
Shaft diameter 2x round counterflanges in stainless steel 1.4404 (PN25 – DN50) 4038589
Lantern flange size code 2x round counterflanges in steel (PN25 – DN50) 4038588
Variants code (if any) By-pass kit 25 bar 4146786
Manufacturer technical index By-pass kit (with Manometer 25 bar) 4146788