Performance Monitoring

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Performance Monitoring Specification For Activated Sludge System

Weekly Sample Parameter

AS system component Parameter Unit Recommended range Sampling


frequency
Primary clarifier Flow rate m3/d Design value Daily
Outlet/effluent BOD 5 mg/L Design value Weekly
COD mg/L Design value Daily
SS mg/L Design value Weekly
AN mg/L Design value Monthly

Aeration tank Flow rate m3/d Design value Daily


BOD 5 mg/L Design value weekly
COD mg/L Design value Daily
SS mg/L Design value Daily
DO mg/L 2-3 (EAAS) Daily
MLSS mg/L 3500-6000(EAAS) Daily
MLVSS mg/L - Daily
pH - 6.5 – 8.5 Daily
F/M kg/(kg.d) 0.05- 0.15 (EAAS) Daily
OUR mgO2/(L.h) - As required
SOUR mgO2/(g.h) 8-20 As required
SVI mL/L 50-100 Daily
Sludge age d 15-30 (EAAS) Daily
Clarifier/sedimentation

-In the tank Sludge level m <1/3 of clarifier depth Daily


Outlet/effluent BOD 5 mg/L *Depends on Weekly
COD mg/L applicable standard Weekly
SS mg/L Weekly
O&G mg/L Weekly
NH3N mg/L Weekly
NO3N mg/L Weekly
Phosphorus mg/L Weekly
pH - Weekly
Temperature Weekly
Daily Sample Parameter

AS system component Parameter Unit Recommended range Sampling


frequency
Primary clarifier Flow rate m3/d Design value Daily
Outlet/effluent COD mg/L Design value
AN mg/L Design value Daily
Design value
Design value Monthly

Aeration tank Flow rate m3/d Design value Daily


BOD 5 mg/L Design value
COD mg/L Design value Daily
SS mg/L Design value Daily
DO mg/L 2-3 (EAAS) Daily
MLSS mg/L 3500-6000(EAAS) Daily
MLVSS mg/L - Daily
pH - 6.5 – 8.5 Daily
F/M kg/(kg.d) 0.05- 0.15 (EAAS) Daily
OUR mgO2/(L.h) - As required
SOUR mgO2/(g.h) 8-20 As required
SVI mL/L 50-100 Daily
Sludge age d 15-30 (EAAS) Daily
Clarifier/sedimentation

-In the tank Sludge level m <1/3 of clarifier depth Daily


Outlet/effluent *Depends on