3
₸b
Mill Tolerance Tb
C
tb
A3
A4
A1
L4
th Th ₸h
d1 A2 C Mill Tolerance
d2
Branch pipe: WELDOLET 12" X 4" A182 F51 SCH 40S X SCH 160 MSS SP-97 NACE
Run pipe: PIPE EFW (E=1.0) 12" A790 UNS S31803 SCH 40S NACE
From vendor drawing dimension “B” = 98.5mm where the branch opening.
Then, d1=98.5 mm
Th= ₸h-mill tolerance
₸h= Nominal thickness of run pipe = 10.3 mm, mill tolerance=12.5%of ₸h
Th= 10.3mm-1.29mm=9.01mm
C= corrosion allowance=0
Then, L4=22.52mm
th = 5.59mm
Then,
tb = [PD / [2(SEW+PY)]] + c
See attached thickness calculation sheet
tb = 1.97mm
Tb= ₸b-mill tolerance
₸b= Nominal thickness of branch pipe = 13.49 mm, mill tolerance=12.5%of ₸b
Tb= 13.49mm-1.68mm=11.8mm
5 mm
12 mm 22.52mm
12mm
mm mm
5 mm
18 mm Consider area A4
A2+A3+A4 = 336.87mm2 +442.74 mm2+285 mm2 = 1064.61 mm2 ≥ A1= 562.91 mm2