MODBUS Comm Data Register PDF

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

1 2 3 4

A
MODBUS_comm_data_register [DB33]
MODBUS_comm_data_register Properties
General
Name MODBUS_comm_data_register Number 33
Type DB Language DB
Information
Title Author
Comment Family
Version 0.1 User-defined ID
B
Name Data type Offset Start value Retain Acces‐ Visible Comment
sible in HMI
from
HMI
Static
Register_4001 array False True True Statusi nivoprekoidaca
[0..15] of
Bool
Regis‐ Bool false False True True
ter_4001[0]
Regis‐ Bool false False True True
C ter_4001[1]
Regis‐ Bool false False True True
ter_4001[2]
Regis‐ Bool false False True True
ter_4001[3]
Regis‐ Bool false False True True
ter_4001[4]
Regis‐ Bool false False True True
ter_4001[5]
Regis‐ Bool false False True True
ter_4001[6]
Regis‐ Bool false False True True
D ter_4001[7]
Regis‐ Bool false False True True
ter_4001[8]
Regis‐ Bool false False True True
ter_4001[9]
Regis‐ Bool false False True True
ter_4001[10]
Regis‐ Bool false False True True
ter_4001[11]
Regis‐ Bool false False True True
ter_4001[12]
Regis‐ Bool false False True True
E ter_4001[13]
Regis‐ Bool false False True True
ter_4001[14]

Owner Project name Regeneracija+pretkomore V11 r3 1/21/2015 Date

Project Path 12:24:05 PM


C:\Documents and Settings\Miki\My Documents\Automation\Regeneracija
Operator
+pretkomore V11 r3
Location

Designed By Description 1st

F
Checked By Description 2nd Language en-US
Approved By 1st View Version Sheet 1-1
1 2 3 4

Name Data type Offset Start value Retain Acces‐ Visible Comment
A sible in HMI
from
HMI
Regis‐ Bool false False True True
ter_4001[15]
Register_4002 array False True True Statusi motora
[0..15] of
Bool
Regis‐ Bool false False True True
ter_4002[0]
Regis‐ Bool false False True True
ter_4002[1]
B Regis‐ Bool false False True True
ter_4002[2]
Regis‐ Bool false False True True
ter_4002[3]
Regis‐ Bool false False True True
ter_4002[4]
Regis‐ Bool false False True True
ter_4002[5]
Regis‐ Bool false False True True
ter_4002[6]
Regis‐ Bool false False True True
ter_4002[7]
C
Regis‐ Bool false False True True
ter_4002[8]
Regis‐ Bool false False True True
ter_4002[9]
Regis‐ Bool false False True True
ter_4002[10]
Regis‐ Bool false False True True
ter_4002[11]
Regis‐ Bool false False True True
ter_4002[12]
Regis‐ Bool false False True True
D ter_4002[13]
Regis‐ Bool false False True True
ter_4002[14]
Regis‐ Bool false False True True
ter_4002[15]
Register_4003 Real 0.0 False True True Level word 1
Register_4004 Real 0.0 False True True Level word 2
Register_4005 Real 0.0 False True True O2 word 1
Register_4006 Real 0.0 False True True O2 word 2
Register_4007 Word 0 False True True Radni sati pumpa 4
Register_4008 Word 0 False True True Radni sati pumpa 5
Register_4009 Word 0 False True True Donja granica alarma po
E
nivou
Register_4010 Word 0 False True True Gornja granica alarma po
nivou
Register_4011 Word 0 False True True Histerezis alarma po ni‐
vou
Owner Project name Regeneracija+pretkomore V11 r3 1/21/2015 Date

Project Path 12:24:05 PM


C:\Documents and Settings\Miki\My Documents\Automation\Regeneracija
Operator
+pretkomore V11 r3
Location

Designed By Description 1st

F
Checked By Description 2nd Language en-US
Approved By 1st View Version Sheet 1-2
1 2 3 4

Name Data type Offset Start value Retain Acces‐ Visible Comment
A sible in HMI
from
HMI
Register_4012 Word 0 False True True Donja granica koncentra‐
cije O2
Register_4013 Word 0 False True True Gornja granica koncen‐
tracije O2
Register_4014 Word 0 False True True Vremensko zatezanje ni‐
voprekidaca u regenera‐
ciji [ms]
Register_4015 Word 0 False True True Vremensko zatezanje ni‐
voprekidaca u pretko‐
B mori [ms]
Register_4016 Word 0 False True True Trajanje koraka 1 [s]
Register_4017 Word 0 False True True Trajanje koraka 2 [s]
Register_4018 Word 0 False True True Trajanje koraka 3 [s]
Register_4019 Word 0 False True True Trajanje koraka 4 [s]
Register_4020 Word 0 False True True Trajanje koraka 5 [s]
Register_4021 Word 0 False True True Trajanje koraka 6 [s]
Register_4022 Word 0 False True True Trajanje koraka 7 [s]
Register_4023 Word 0 False True True Trajanje koraka 8 [s]

Owner Project name Regeneracija+pretkomore V11 r3 1/21/2015 Date

Project Path 12:24:05 PM


C:\Documents and Settings\Miki\My Documents\Automation\Regeneracija
Operator
+pretkomore V11 r3
Location

Designed By Description 1st

F
Checked By Description 2nd Language en-US
Approved By 1st View Version Sheet 1-3